Vous êtes sur la page 1sur 1

.

LKH-/ LKHPF-/ LKHI-/ LKH Evap-60, 50 Hz

ky Performance Curves
LKH-/ LKHPF-/ LKHI-/ LKH Evap-60, 50 Hz
Motor: 3000 rpm. synchr. Motor: 1500 rpm. synchr.
Tolerance: ±5% Tolerance: ±5%.
Impeller, Max. dia.: 210 mm Impeller, Max. dia.: 210 mm
Impeller, Min. dia.: 160 mm Impeller, Min. dia.: 160 mm
Pump inlet, Dia.: - 101.6 mm, DN 100 Pump inlet, Dia.: - 101.6 mm, DN 100
- DN 150 - DN 150
Pump outlet, Dia.: - 101.6 mm, DN 100 Pump outlet, Dia.: - 101.6 mm, DN 100
- NDN 100 - DN 100
Performance data refer to water at 20°C. Performance data refer to water at 20°C.
NOTE! NOTE!
The curves refer to motor: 30 kW, 2955 rpm. asynchr., 50 Hz. For smaller motors, The curves refer to motor: 4 kW, 1425 rpm. asynchr., 50 Hz. For smaller motors,
reduce head (H) with:3% for 11 - 22 kW. reduce head (H) with: 5%.
6% for 5.5 - 7.5 kW.
DO NOT FORGET THE SAFETY FACTOR. DO NOT FORGET THE SAFETY FACTOR.
H (m) NPSHr (m) H (m) NPSHr (m)
80 20

3000-0040
3000-0039

70

60 15
50

40 10
30
200 210 210
20 5 200
180 190 190
10 160 170 10 170 180 10
160
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 0 30 60 90 120 Q (m³/h)
Q (m³/h)

P (kW) P (kW)
40 5
35
4
30 210 210
200
25 200
3
20 190 190
180 2 180
15
170 170
10 160 160
1
5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 0 30 60 90 120 Q (m³/h)
Q (m³/h)

Note: If Clear Flow impeller is mounted the performance can be up to 10% lower than on the curves shown.