Vous êtes sur la page 1sur 5

Region I

Schools Division Office City of San Fernando


SAN FERNANDO SOUTH CENTRAL INTEGRATED SCHOOL
Tanqui, City of San Fernando, La Union

SECOND QUARTER EXAM


EIM 10

Name: ______________________________Grade/Sec: ________ Date: _______ Score: _________

I. MULTIPLE CHOICE: Read and analyse. Choose the letter of your answer and blanken the
circle that corresponds your answer.

ABCD
O O O O 1. Electrical current is measured in..?
A. Amperes B. Coulombs C.Volts D.Watts

O O O O 2. THIS is THE fundamental conventional graphic illustration of an electrical circuit.


A. Wiring Diagram B. Pictorial Diagram
C. Schematic Diagram D. Line Diagram

O O O O 3. A type of electrical print that shows external appearance of each component in


a circuit.
A. Wiring Diagram B. Pictorial Diagram
C. Schematic Diagram D. Line Diagram

O O O O 4. A wiring diagram using standard electrical symbols for wiring devices. It is a


representation of the elements of a system using abstract and graphic symbol
rather than realistic pictures.
A. Wiring Diagram B. Pictorial Diagram
C. Schematic Diagram D. Line Diagram

O O O O 5. It is a presentation of electrical connections of wiring devices using single line


and with slashes indicating the number of conductors in a line.
A. Wiring Diagram B. Pictorial Diagram
C. Schematic Diagram D. Line Diagram

O O O O 6. It is a sketch of the actual connections of electrical devices in a circuit or wiring


installations.
A. Wiring Diagram B. Actual Connection Diagram
C. Schematic Diagram D. Line Diagram

O O O O 7. These are small drawings or pictograms used to represent various electrical


devices in a diagram or plan of an electrical circuit.
A. Electrical Symbols B. Legends
C. Schematic Diagram D. Actual Connection Diagram

O O O O 8. Electricity is made at a power plant by huge


A. Motor B. Generator C. Coil D. Wire

O O O O 9. The standard unit of power is


A. Volt B. Ampere C. Watt D. Ohm

O O O O 10. Prevented maintenance of an equipment?


A. Prolongs life B. Keeps the equipment in good condition
C. Makes beautiful D. Makes someone safety

O O O O 11. To prevent accidents and injuries in the workshop you must understand and
follow safety rules
A. True B. False

O O O O 12. The screwdriver type that could be used to tighten or loosen the
screw given in the figure is:
A. Allen key B. Torz C. Phillips D. Slot Head

O O O O 13. The sign shown in the picture is


A. Warning B. Advisory C. Mandatory D. None of the above

O O O O 14. The meter shown in the picture


A. Multimeter B. Voltmeter C. Power meter D. None of the above

O O O O 15. All exposed metal in electrical circuit should be


A. Eathed B. Connected together C. Kept away D. Painted

O O O O 16. Before working on a circuit, you must.................. the power supply


A. Switch on B. Switch off C. Hold D. Throw

O O O O17. A personal protective equipment or PPE


A. Prevents heavy equipment B. Prevents injuries
C. Prevents accident D. Prevents short circuit

O O O O 18. Green/Yellow wire is always considered as part of the live circuit


A. True B. False

O O O O 19. Fuse is used to protect the circuit against earth-leakage current


A. True B. False

O O O O 20. Electric Shock occurs when a person becomes part of the


A. Circuit B. Path C. Team D. Hazard

O O O O 21. The severity of an electric shock depends more on the voltage when
compared to the current.
A. True B. False

O O O O 22. Mandatory signs are used to indicate that a specific course of action must be
taken.
A. True B. False

O O O O 23. Overload currents occurs when


A. Equipment is overloaded B. Installation is abused
C. Installation has been badly designed D. All of the above

O O O O 24. The difference between a FUSE and Circuit Breaker (CB)


A. Fuse can use many times but CB only once
B. Fuse only once and but CB many times
C. Fuse and CB can use many number of times
D. All of the above

O O O O 25. One of the devices is not used for protection


A. RCD residual-current circuit breaker B. MCB Miniature Circuit Breaker
C. FUSE D. male plug

O O O O 26. Which of these best describes a hazard?


A. Something that is potentially harmful B. Tools lying around on the floor
C. Unlabelled chemicals D. All of the above

O O O O 27. What is the cause of most accidents?


A. Poisoning B. Slips, trips and falls
C. Electrocution D. Suffocation

O O O O 28. Where would you go if your fire alarm was activated?


A. The manager's office B. The fire assembly point
C. Go to your car and wait D. Clock out and go home immediately

O O O O 29. Who should report unsafe working practices at work?


A. Your line manager only B. Your employer
C. Your safety representative D. Anyone who notices it

O O O O 30. A switch is used in installation of one lamp controlled by two locations is?
A. One way switch B. Two way switch
C. Three way switch D. Four way switch

O O O O 31. Pull down the fuse cut off of a transmission line before
A. Cutting the wires B. Working on electrical
C. Climbing the electrical pole D. Disconnecting

O O O O 32. A competent person dealing with a hazardous situation


A. must wear appropriate PPE B. Display a health and safety poster
C. Reduces the risk D. Increases the risk.

O O O O 33. In a simple series circuit, why does the bulb light when you close the switch?
A. the switch produces electricity
B. Closing the switch completes the circuit
C. losing the switch breaks the circuit
D. Opening the switch completes the circuit

O O O O 34. A switch is used in installation of one lamp controlled by three locations is?
A. One way switchB. Two way switch C. Three way switch D. Four way switch

O O O O 30. A switch is used in installation of one lamp controlled by two locations is?
A. One way switch B. Two way switch
C. Three way switch D. Four way switch

Direction: 36-40 Put the following steps in order label them with numbers 1-5
36.________ Attach fittings to the wall

37.________ Chalk out a wiring plan

38. _______ Measure the amount of conduit that you would need.

39.________ Choose the right material for installing electrical conduit fittings

40.________ Make the necessary bends

41-50. Based on the Pictorial Diagram of “one lamp controlled by a single pole switch and a
convenience outlet”, draw the following:

•Actual connection diagram

•Line diagram

Actual connection diagram

Line Diagram

PREPARED BY:
FRANK MICHAEL L. JACLA
TEACHER-1

CHECKED BY:
NARCIE RICKY A. APILADO
HEAD TEACHER 1

NOTED BY:
BRENDA A. SABADO

PRINCIPAL IV

Vous aimerez peut-être aussi