CIP Troubleshooting
Failures & Possible Solutions
Problem #1
Solution?
Solution #1
Solution?
Solution #2
Cause or failure mode
Gaskets leaking or not used on inlet to return pump
TOV pulsing is too long, resulting in stall of return solution and poor evacuation
of tank
Restrictor orifice in CIP supply line removed or distorted, resulting in hydraulic
unbalance of system
Program drain times too short or pre-rinse times too long
Foreign material in CIP return pump impeller or in CIP return circuit
Return line filter full of materials
Leaking CIP return pump seal, resulting in air incorporation and cavitation
CIP return hose or jumper leaking or crushed
Return pump air eliminator fouled
Problem #3
Solution?
Solution #3
Cause or failure mode
Conductivity cell or sensor soiled or fouled
CIP operator overriding detergent feed system by manually adding detergent
to circuit
Electronic controller set-point changed
Control wire from sensor or probe to electronic controller off or loose
Chemical feed pump malfunction
Conductivity cell exposed to air by water level in tank dropping below probe
Empty detergent dispenser or barrel
Detergent time feed – timer setting changed, time malfunction
Plant water pressure increased, adding more water volume to circuit
Detergent injection check valve or anti-siphon valve malfunction
Problem #4
Solution?
Solution #4
Solution?
Solution #5
Solution?
Solution #6
Solution?
Solution #7
Solution?
Solution #8
Solution?
Solution #9
Solution?
Solution #10
Solution?
Solution #11
Solution?
Solution #12
Blue Metal
Protein film - improper chemical
Temperature shock - hot water on cold tank or water temperature
too high
Water softener needs recharging
Magnesium deposits in water (12 ppm)
Cleaning Failures
Bronze/Brown metal
Iodine based sanitizer concentration elevated
Post-rinse temperature too high
Improper rinse
High iron content in water (3 ppm) or more
Iron fittings used somewhere in the CIP circuit or system
Elevated temperatures during base caustic wash
Cleaning Failures
Deterioration of gaskets
Excessive cleaner strength
Excessive cleaning temperature
Sanitizing with chlorine solution too long in advance of equipment
being used
Failure to follow cleaning with adequate rinsing