1 Pump ty pe End Suction Volute Pump Fluid "Water, clean"
2 Number of pumps / Reserv e 1 / 0 Liquid temperature °C 20
3 Flow m³/h 300 Kin. v iscosity m²/s 1E-6
4 Head m 50 Vapour pressure atm 0.0217
5 Static head m 30 PH v alue 7
6 Inlet pressure atm 0.4 Density kg/m³ 1000
7 Av ailable sy stem NPSH 8 Solids Weight % 0
8 Env ironmental temperature °C 20
Pump
9 Pump name 150x125 FS4LA 5 75 Frequency Hz 50
10 Design End Suction Volute Pump Installation ty pe with base, motor
11 Manuf acturer PTEI Impeller Max. m 0
12 Speed rpm 1450 Diameter Designed m 0
13 No. of Stage 1 Min. m 0
14 Connection Suction side JIS 10K Flow Operating m³/h 333
15 Connection Discharge side JIS 10K Max- m³/h 399
16 Max Working Pressure atm 9.8692 Min- m³/h 90
17 Shut-of f head atm 6.74 Head Operating m 54.6
18 Total weight kg See the table of "Dimensions". - (Qmax.) m 49.7
19 Shaf t power kW 60.31 - (Qmin.) m 64.9
20 Max. Shaf t Power at max. impeller kW 68.05
21 Required NPSH m 3.1 Ef f iciency % 82.0
M aterials
22 Casing Cast iron M.S.mating ring Ceramic
23 Impeller Bronze M.S.seal ring Carbon
24 Shaf t 403 Stainless steel
25 Casing ring Bronze
26 Ball bearing .
27 Mechanical seal .
M otor
28 Manuf acturer TECO Insulation class F
29 Ty pe 250MC_B3_75_3_400 Phases 3~
30 Specif ic design TEFC / 50 Hz / Pole pairs 2 Frame size 250 MC
31 Rated power kW 75 Weight kg 550
32 Number of poles 4 Electric v oltage V 400
33 Speed rpm 1475 Electric current A 124
34 Degree of protection IP 55
35
Remarks
Performance curve Pump name 150x125 FS4LA 5 75
Test standard: ISO 9906:2012 - Grade3B Water, clean [100%] ; 20°C; 998.3kg/m³; 1.005E-6m²/s
Head
[m]
60
Eff.
82% 54.6 m
50 Ø 0.424
1 Frequency
40
30
20
10
0
Shaft power P2
Ø 0.424 (P2)
[kW]
60.3 kW
40
20
0
NPSH-values 82 %
[m]
[%] Efficiency Ø 0.424
Ø 0.424
4
3.6
60 3.2
3.08 m
2.8
2.4
40 2
1.6
1.2
20
0.8
0.4
333 m³/h
0 0
0 40 80 120 160 200 240 280 320 360 400 440 [m³/h]
Dimensions Pump name 150x125 FS4LA 5 75