Vous êtes sur la page 1sur 4

<<Contents>> <<Index>>

General Terminal Boards (for FIO)


Specifications
GS 33K50H50-50E

[Release 5]

 GENERAL
This document describes the specifications of terminal boards used for FIOs of CENTUM VP systems.

 STANDARD SPECIFICATIONS
Modules Connection
Model Description Points Terminals Weight Specifications
Connected Cable
For 2-wire Transmitter AAI135
AEA3D (for single or dual redundant 8 pts x 4 M4 screws AAI835 KS1 1.8 kg
modules) AAP135
AAI135
8 pts x 2 M4 screws AAI835
AAP135
AAI141
AAV141
For analog signals AAV142
AEA4D (for single or dual redundant AAV144 KS1 1.5 kg
modules) AAB841
16 pts x 2 M4 screws
AAI841
AAV542
AAV544 Insulation resistance: 100
AAI143 MΩ or greater at 500 V DC
AAI543
For thermocouple Withstanding voltage: 500
AET4D (for single or dual redundant 16 pts x 2 M4 screws AAT145 KS1 1.8 kg V AC for 1 minute
modules)
ADV151
For digital signals AKB331
ADV551
AED5D (for single or dual redundant 32 pts x 1 M4 screws 1.5 kg
modules) ADV161 (*1)
AKB337
ADV561 (*1)
For fieldbus
AEF9D (for single or dual redundant 4 ports x 4 M4 screws ALF111 AKB336 1.8 kg
modules)
For resistance temperature
AER4D 16 pts M4 screws AAR145 AKB335 1.5 kg
detectors
For resistance temperature
MRT(*2) 16 pts x 2 M4 screws AAR145 KS8 1.8 kg
detectors
Insulation resistance: 100
MΩ or greater at 500 V DC

Withstanding voltage:
For digital signals ADV141 AKB332
Between commons;
AEC4D (for single or dual redundant 16 pts x 2 M4 screws ADV142 AKB333 1.8 kg
1500 V AC for 1 minute,
modules) ADR541 AKB334
common minus side
every 8-channel
Between signal and case;
2300 V AC for 1 minute

Note: Be sure to leave the connector caps on connectors that are not used, in order to protect the connector pins and prevent
dust from accumulating on them.
*1: Two sets of AED5D or AKB337 are required for one set of ADV161 or ADV561.
*2: For details on the MRT, see GS 33K55R40-50E.

Yokogawa Electric Corporation GS 33K50H50-50E


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Aug. 2011 (YK)
Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 1st Edition Aug. 19, 2011 (YK)
<<Contents>> <<Index>> 2
 EXTERNAL DIMENSIONS
 Terminal Boards
AEA3D
Unit: mm
(85) 482.6
18.4 66.6 8.75 465.1
34.6 21.3 440

57.15
132.5

37.7 Hole for 19-inch rack mounting


(4 M5 screw holes)
F01E.ai

AEA4D, AET4D
Unit: mm
(85) 482.6
18.4 66.6 8.75 465.1
34.6 21.3 440

88.1

37.7 Hole for 19-inch rack mounting


(2 M5 screw holes)
F02E.ai

AED5D
Unit: mm
(85) 482.6
18.4 66.6 8.75 465.1
34.6 21.3 440

88.1

37.7 Hole for 19-inch rack mounting


(2 M5 screw holes)
F03E.ai

All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 33K50H50-50E Aug. 19, 2011-00
<<Contents>> <<Index>> 3
AEC4D
Unit: mm
(85) 482.6
18.4 66.6 8.75 465.1
34.6 21.3 440

57.15
132.5

37.7 Hole for 19-inch rack mounting


(4 M5 screw holes)
F04E.ai

AER4D
Unit: mm
(85) 482.6
18.4 66.6 8.75 465.1
34.6 21.3 440

88.1

37.7 Hole for 19-inch rack mounting


(2 M5 screw holes)
F05E.ai

AEF9D
Unit: mm
(85) 482.6
18.4 66.6 8.75 465.1
34.6 21.3 440

57.15
132.5

37.7 Hole for 19-inch rack mounting


(4 M5 screw holes)
F06E.ai

All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 33K50H50-50E Aug. 19, 2011-00
<<Contents>> <<Index>> 4
 MODELS AND SUFFIX CODES
Terminal Board for Analog Terminal Board for Resistance Temperature
(single and dual-redundant) Detectors (single and dual-redundant)
Description Description
Terminal Board for Analog Terminal Board for resistance
Model AEA3D (single and dual-redundant, 8- temperaure detectors
channel) Model AER4D
(single and dual-redundant, 16-
-0 Always 0 channel)
Suffix
0 Basic Type -0 Always 0
Codes Suffix
1 With ISA Standard G3 option 0 Basic Type
Codes
1 With ISA Standard G3 option
Terminal Board for Analog
(single and dual-redundant) Terminal Board for Fieldbus
(single and dual-redundant)
Description
Terminal Board for Analog Description
Model AEA4D (single and dual-redundant, 16- Terminal Board for Fieldbus
channel) Model AEF9D
(single and dual-redundant)
-0 Always 0 -0 Always 0
Suffix Suffix
0 Basic Type 0 Basic Type
Codes Codes
1 With ISA Standard G3 option 1 With ISA Standard G3 option

Terminal Board for Thermocouple


(single and dual-redundant)  ORDERING INFORMATION
Description Specify model and suffix codes.
Terminal Board for Thermocouple
Model AET4D (single and dual-redundant, 16-
channel)  TRADEMARK
-0 Always 0 • CENTUM is a registered trademark of Yokogawa
Suffix Electric Corporation.
0 Basic Type
Codes • Other company names and product names in this
1 With ISA Standard G3 option document are registered trademarks or trademarks of
their respective holders.
Terminal Board for Digital (single and dual-
redundant)
Description
Terminal Board for Digital
Model AED5D (single and dual-redundant, 32-
channel)
-0 Always 0
Suffix
0 Basic Type
Codes
1 With ISA Standard G3 option

Note: When the AED5D is used in voltage output mode,


it does not conform to Non-Incendive standard.
Terminal Board for Digital (single and dual-
redundant)
Description
Terminal Board for Digital (single and
Model AEC4D
dual-redundant, 16-channel)
-5 For 100 V - 120 V AC input
-6 For 220 V - 240 V AC input
Suffix
-7 For Relay output
Codes
0 Basic Type
1 With ISA Standard G3 option

All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 33K50H50-50E Aug. 19, 2011-00
Subject to change without notice.

Vous aimerez peut-être aussi