EUROLYSER
High-tech Random
Access Clinical
Chemistry Analyzer
Most important
considerations …..
Accuracy
Reproducibility
Reliability
The Star ….
Throughput up to 180 Tests/hour under
speed optimized condition
Random Access as well as optimized
batch mode available
Direct Reading System: No flow cell
STAT available at anytime
Not Just Speed……
2 independent needles for reagents and
samples
Preheated Pipetting arms reduces
incubation time
Faster washing of needles through
separate wash-stations
Covers all kind of Biochemistry Tests including
Drug Assay, Immunoturbidimetric Assay
Automatic pre and post-dilution: more choice
and accuracy for icteric or lipemic samples.
Analysis Modes: End point, Kinetic, Initial Rate,
Multi point endpoint, Multipoint initial rate, and
Calculated methods
Really Flexible
25 reagent positions
50 sample positions
25 primary tubes
25 positions for serum cups
(controls, standards and samples)
Removable Inner Carousel for
overnight refrigeration
Outer Carousel: 300 test positions (75
x 4 cuvettes) with incubators.
Primary tubes can be used instead of
sample cups.
Flexibility – another name of
user friendliness
reagents
Temperature control for reaction cuvettes
Reagents
on tray
Samples on
tray
Reagents
Software: more and
more…
Display of status during process run
Automated calibration and QC routines with L-J
curve
Maximum 1day requires
to train a technician
True open channel:
Other manufacturer’s
reagents can be
programmed
Overall value of money
Extremely reliable LED system: No lamp
replacement
Micro Volume of reagents
Low water consumption: ½ lit/hr in
highest throughput
Low Power Consumption: 150 VA only.
Most cost effective…..
Minimized yearly maintenance
Syringe pumps: No change of peristaltic
tubes
High quality probes: No cost of tips
Reliable Hardware inputs
Upgraded technology
High precision independent pipettors
equipped with extremely precise
frequency based level sensors with
each probe.
Microsoft Windows Based user
friendly software: NO DOS Based
software
DOS is command based and user
interpretations are more….
Upgraded technology
Both Test wise or Patient Wise
reporting is possible
Optional on-board cooling
Infinite data-storage depending
on the size of hard disk
Service: The backbone
Our Experience and Expertise
Complete commitment
Multiple engineers trained in AUSTRIA
All engineers well equipped with
Low total cost of Ownership Most cost effective solution in the market
EUROLYSER CCA 180
MARKETING MANUAL
Notice
Every effort has been made to avoid errors in text and diagrams, however, Eurolyser Diagnostica
GmbH, assumes no responsibility for any errors which may appear in this publication.
It is the policy of Eurolab to improve products as new techniques and components become available.
Eurolab therefore reserves the right to change specifications at any time.
EUROLYSER CCA 180 is a fully automated, random access Clinical Chemistry Analyser for wet
chemistry applications. It has an open structure, so that reagents from most manufacturers can be
used on the system.
EUROLYSER CCA 180 is computer controlled and uses the Software Package "DETect" for data
reduction and result evaluation. It is a dedicated walk away system.
EUROLYSER CCA 180 has been developed in a way as to maximise throughput at maximum
comfort, and at the same time to minimise maintenance efforts to be taken by the user.
EUROLYSER CCA 180 is fitted with a patented LED based, maintenance free linear photometer,
featuring 20 reading channels for individual wavelength selection and maximum flexibility.
Target customers for EUROLYSER CCA 180:
Small and middle size hospitals
Doctors offices
Lab – communities
Emergency rooms
Backup unit for big analysers in big reference labs
System Characteristics
Access Modes:
Random Access
Stat (immediate access and execution)
Analysis Modes:
Endpoint (Substrates)
Kinetic (Enzymes)
Initial Rate (fixed time kinetics)
Multipoint (non - linear tests)
Serum Blank
Bichromatic
Intermethode Calculation (LDL friedewald etc.)
Throughput:
150 - 180 Tests/hr endpoint monoliquid
Liquid Handling:
2 independent Syringes: Sample: 1 - 250µl in 1µl steps
Reagent: 5 - 999µl in 1µl steps
Minimum reaction volume 180µl
High pressure washing
Autocleaning
Easy maintenance
Measurement System:
Maintenance Free !
Three year warranty on entire optical system!
Light sources: LED (light emmiting diode)
Detectors: Photodiodes
Temperature controlled
5 inbuilt photometers, 4 channels each
Standard filters: 365, 405, 505, 546 & 620nm (4 each)
Resolution: 0,0001 ABS
Accuracy: <1% CV at 1ABS / 405nm
Precision: + / - 0,5% at 1 ABS / 405nm
Temperature Control:
Optional Reagent cooling ambient minus 10°C (water circulation with external cooler)
Cuvette heating (electrical) in carousel and reading path: 37°C
Carousel:
25 reagent positions; 50 positions without serum cups
50 sample positions (random access) for samples, standards and controls
300 test positions (75 x 4 cuvettes)
Customized carousels available
Power Requirements:
85-264V, 50/60 Hz (autodetecting)
Measures:
Dimensions: 810 x 550 x 550 (w x d x h)
Weight: 28kg
Environmental requirements:
18 - 35°C
10 - 90% relative Humidity
Options:
External ISE module for electrolytes
Handheld Barcode Reader for positive Sample ID
Reagent cooling
Disposables:
Cuvette block for 4 tests each
Reagent bottles
Serum Cups
Cleaning agent for System liquid
Special Cleaning Agent for weekly maintenance
General
Feature Benefit
Open system Reagents from any manufacturer can be used after
a short application procedure
Direct Reading System No carryover problem as normally known from
flow-cell systems
Disposable Cuvettes same quality for each test
Can use samples from primary tubes no intermediate manual pipetting steps required
Lowest Total cost of Ownership (TCO) Most cost effective solution on the market, if
purchase price, consumables and maintenance cost
are compared over the live span of the instrument
Instrument
Liquid Handling
Handling
Feature Benefit
Open structure, all parts easily accessible easy maintenance
High precision Syringe pumps and Membrane long life time, minimised precision drift compared
pumps to peristaltic pumps
Two independent high precision syringes, one No compromises in pipetting precision:
for sample and one for reagent pipetting.
- sample from 1µl up to 250µl in 1µl steps
- reagent from 5µl to 999 µl in 1µl steps
Min. reaction volume 180µl highest output from valuable reagents
Syringe modules are standard products as used approved quality
in high throughput pipetting robots
Pick- and Drop system minimised death volume
Stainless steel probes maximised life time, optimised washing results
Liquid detection (Sample & Reagent) process safety for full walk away operation
Both Probes heated minimised pre-incubation times
High pressure probe washing (sample & minimised carry over
reagent)
Measurement System
Feature Benefit
LED technology Maintenance free, low power consumption, no
heat development
Patented strange light compensation independent from light environment
20 reading channels fast reading with flexible wavelength selection
Linear order of reading channels shortest handling distances
Positive cuvette detection maximised process safety
Temperature controlled optimised reaction environment, especially for
kinetic evaluations
more than 500 ABS Modules installed in the field approved quality
in other OEM systems
General
The Eurolyser is not the cheapest analyser in its (bench top) class. How is it possible that the
instruments can offer the lowest cost per test?
test
Over the life span of the instrument more than 95% (!) of the test costs are determined by the
reagent consumption. Hence the instrument purchase price is not the most important factor – the
running cost determine if the system (instrument + reagent consumption + maintenance cost) is cost
effective. Due to its outstanding LED photometer the Eurolyser needs less reagent volume than any
other instrument in its class – which results in the lowest cost per test (also called: Total Cost of
Ownership)
Why is a LED (light emitting diode) based photometer better than a halogen lamp photometer?
LED’s have several advantages: they do not drift in wavelength, therefore they are much more
accurate. This accuracy in turn allows lower reading volume of reagents, which results in
tremendous cost savings for the user; LED’s generate no heat – no cooling fan is necessary, no dust
in the instrument, no energy wasted. Additionally, LED’s life span is 100.000 (!) times higher than the
life span of a halogen lamp – they are literally maintenance free! (which of course also results in
lower running cost
What are the different types of analysis methods that the instrument can handle, like specific
proteins ?
Eurolyser handles all kinds of tests, which are made under wet chemistry environment.
What is the sample processing capacity or throughput for end points/enzyme tests?
Throughput: more than 160 - 180 tests/hr. (End Point Mono Liquid) Sample throughput is depending
on how many tests are performed per sample. So you have to divide 160 - 180 by the number of
tests per sample to have the sample throughput.
Calibration
What is
is the calibration frequency suggested ?
System is in optics absolutely stable, so that the calibration frequency only depends on the reagents
used. Eurolyser is an open system, so the calibration frequency depends on the reagents
manufacturer.
Can test be recalibrated with as well as without samples, or only during a run?
Calibration of the system is a completely separated “run” with only calibrators and controls.
Is the calibration process ‘automatic’ (as in Hitachi 912) or semi automatic - as in Vital Selectra II
Semi automatic
Software Flexibility
Are the test parameters alterable that is, is the system open?
Yes, the system is fully open.
Does the system have graphic facility for display of standard curves?
Yes
Instrument
What is the path length of the cuvette, or is it variable, based on pipetting volume?
The optical path is appr. 6,8 mm and not variable. The minimum volume required for proper
measurements is 180µl per test in total in order to fill the reading chamber of the cuvette.
23°c?
What is the reagent cooling temperature reached, say at an ambient temperature of 23°
appr. 10°C below ambient
How many test reagents can be added automatically for a test - 2,3 or 4 ?
Up to 3.
What are the volumes of the reagent containers and what are dead volumes?
The volume of the reagent containers is 50ml,20ml or 10ml (the dead volume is less approx 1 ml.)
Is it possible to use adapters for say different volumes say 30 or 35ml, 20 or15ml, or 3-
3-5ml for low
volume tests like CK-
CK-MB, amylase etc?
Yes, there is an adapter available as an option, which is placed in a reagent – bottle position of the
carousel. Iot helds a 4ml tube for small volumes.
Are the sample/reagent pick up direct like in ILab 600 (from Instrumentation Laboratory, USA) or
involving dead volume losses like in Hitachi 911 or 912?
The sample / reagent pipetting uses a “pick and drop” system with almost zero death volume.
How are the samples and reagents identified – by barcode reader or scanned across?
By optional, handheld barcode reader, connected to PC.
Measurement
re--
Is it possible to dilute sample automatically, and rerun if substrate depletion occurs and re
measure?
Results which exceed the linearity limit of the chemistry are automatically re-tested. The first re-run
will be with lowered sample amount to increase the Linearity range. If still out of range, sample will
automatically be re-tested by adding double reagent volume additionally to the decreased sample
volume.
Optics
What is the type of optics employed - filters or grating or photodiode array system?
Interference filters
What are the unique features and benefits of the “patented linear type photometer” over
conventional type?
This photometer is fitted with LEDs as light sources, which make the system maintenance free. The
reading is disconnected from the other process steps, this means that during reading (e.g. kinetics),
the instrument continues pipetting.
It is connected to special electronics, which make it fully independent from ambient light. The 20
inbuilt photometers are in linear order, the cuvettes are moved like in a street through all 20
channels, and each cuvette is measured at the required position with the required wavelengths.
The patient sera used for this evaluation were provided by the Central lab of the Salzburg County
Hospital. The chemistry used was identical in brand as originally used by the State Hospital. The
testing was done within the facilities of Eurolab by an independent Biochemist (Dr. Pichler) from the
University of Salzburg. The results obtained have been directly compared to the original results from
the Central Lab.
Instrument: Patient
Hitachi 1 4.2 116 8.1 77 76 166 86 168 26 222
Eurolyser CCA 180 1 4.25 119.98 7.97 78.51 83.09 165 84.35 165.82 25.4 203.27
Cholesterol: Results:
Pat. ID Hitachi Eurolyser CCA 180 350
1 77 78.51
300
2 132 131.4
250
3 102 106.06
200
4 242 255.3
5 129 136.61 150
6 222 233.75 100
y = 1,0286x + 1,4643
7 113 119.22 50
R2 = 0,9966
8 136 139.08 0
9 175 169.02 0 100 200 300 400
10 179 171.63
Triglycerides Results:
Pat. ID Hitachi Eurolyser CCA 180
1 76 83.09 300
2 87 90.5 250
3 71 76.12 200
4 273 283.26
150
5 304 319.28
100
6 181 174.46 y = 1,0381x - 2,3851
7 105 107.93 50 R2 = 0,9861
8 78 81.49 0
9 124 129.14 0 50 100 150 200 250 300
10 95 103.28
Glucose Results:
Pat. ID Hitachi Eurolyser CCA 180
200
1 116 119.98
2 94 95.82 150
3 177 187.07
4 108 117.18 100
5 116 128.02 y = 1,0079x + 5,9655
50
6 84 95.19 R2 = 0,9873
7 107 113.24 0
8 169 176.18 0 50 100 150 200
9 148 151.71
10 115 119
Urea Results:
Pat. ID Hitachi Eurolyser CCA 180 200
1 166 165
2 31 30.68 150
3 48 48.63
100
4 29 29.53
5 116 116.95 y = 1,0049x - 1,1837
50
6 38 35.32 R2 = 0,9985
7 20 18.53 0
8 44 38.79 0 50 100 150 200
9 29 28.37
10 22 22
GGT Results:
Pat. ID Hitachi Eurolyser CCA 180 140
1 26 25.4 120
2 109 112.49 100
3 124 128.55 80
4 15 13.85 60
y = 1,0427x - 1,4709
5 34 28.33 40
20 R2 = 0,9976
6 10 9.83
7 11 10.92 0
8 4 2.96 0 50 100 150
9 6 4.57
10 18 20.62
GOT Results:
Pat. ID Hitachi Eurolyser CCA 180 100
1 86 84.35 80
2 16 20.31
60
3 37 40.1
4 9 11.27 40
y = 0,9385x + 3,5133
5 23 21.09 20
R2 = 0,9909
6
0
7 8 9.56
0 20 40 60 80 100
8
9 20 21.15
10 7 13.61
Amylase Results:
Pat. ID Hitachi Eurolyser CCA 180
400
1 222 203.27 350
2 54 50.67 300
3 55 51.55 250
4 38 36.54 200
150 y = 0,9089x + 3,9401
5 377 341.93 100
6 60 60.1 50 R2 = 0,9975
7 21 20.44 0
8 185 185.85 0 100 200 300 400
9 37 35.53
10 38 41.47
GPT Results:
Pat. ID Hitachi Eurolyser CCA 180 200
1 168 165.82
2 33 32.47 150
3 41 41.78
4 12 15.65 100
5 21 26.56 y = 0,9703x + 2,6366
50
6 12 15.2 R2 = 0,9988
7 9 10.33 0
8 8 9.59 0 50 100 150 200
9 12 12.66
10 5 7.76
Repeatability:
SD 0.19 1.72 2.33 2.48 3.25 1.19 3.02 0.99 0.02 0.06 3.25
Avg 27.19 86.26 166.28 218.01 180.07 80.60 122.69 88.11 4.38 8.67 180.07
CV % 0.71% 1.99% 1.40% 1.14% 1.81% 1.47% 2.46% 1.12% 0.56% 0.74% 1.81%
SD 0.15 0.20 0.53 1.65 1.20 2.48 0.56 0.75 0.08 0.04 1.20
Avg 21.30 12.14 7.88 44.94 25.12 198.87 130.27 125.48 5.59 3.37 25.12
CV % 0.69% 1.67% 6.67% 3.67% 4.78% 1.25% 0.43% 0.60% 1.47% 1.23%
1.23% 4.78%