Design of Combined Footing F3 STEMS CONSULTANTS (PTE) LTD Date: 16/04/2000 Designed: S A Karunaratne Reinforcement fy = 460 N/mm2 Materials
Concrete fcu = 25 N/mm2 L1 = X= L3 =
Density of Concrete 24 kN/m3 0.15 2.133 0.417 Allowable Bearing Pressure pall = 100 kN/m 2 W1 = L2 = W2 = 350 4 400 Service Load W1 = 350 Kn Ultimate Column Load N1 = 1000 kN L = L1+L2+L3 = 4.567 Service Load W2 = 400 Kn BW = 300 Ultimate Column Load N2 = 1200 kN Data
Distance boundary to column L1 = 0.15 m BD = 600
Distance between columns L2 = 4 m Assume foundation thickness TF = 250 mm TF = Depth of beam BD = 600 mm 250 BF = 1795 Width of beam BW = 300 mm
Approximate Pad Area A=(W1+W2)/pall 8.2 m2
C G from W1 X= W2L2/(W1+W2) 2.133 m For uniform pressure L= 2(L1+X) 4.567 m Distance from W2 L3 = L-L1-L2 0.417 m Width of footing BF = A/L 1795 m Design and Output I
407034065.xls STEMS
Project : BOI Horana
STEMS Design of Combined Footing F3 STEMS CONSULTANTS (PTE) LT Date: 16/04/2000 Designed: S A Karunaratne Desidn Output II Design Output III Design output IV