Vous êtes sur la page 1sur 28

OMStar

15.2.T1
Release Notes

Issue 01

Date 2017-12-28

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the commercial contract made between
Huawei and the customer. All or partial products, services and features described in this document may
not be within the purchased scope or the usage scope. Unless otherwise agreed by the contract, all
statements, information, and recommendations in this document are provided "AS IS" without warranties,
guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com

Email: support@huawei.com

Issue 01 (2017-12-28) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes About This Document

About This Document

Author
Prepared By Wang Han (employee ID: Date 2017-12-28
00223891)
Reviewed By Liu Min (employee ID: Date 2017-12-28
00216548)
Tested By Li Xuge (employee ID: Date 2017-12-28
00190089)
Approved By Dong Wei (employee ID: Date 2017-12-28
00372366)

Change History
Issue Date Author Description

01 2017-12-28 Wang Han (employee ID: This issue is the first official
00223891) release.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Contents

Contents

About This Document....................................................................................................................ii


1 Version Requirements..................................................................................................................1
1.1 Product Version..............................................................................................................................................................1
1.2 Related Product Versions................................................................................................................................................1
1.3 OS and Database Versions..............................................................................................................................................5
1.4 Antivirus Scanning Results.............................................................................................................................................6

2 Version Compatibility..................................................................................................................9
2.1 Compatibility with Earlier Versions...............................................................................................................................9

3 Important Notes...........................................................................................................................10
3.1 Impact of the Anonymous Policy on OMStar Features................................................................................................11

4 15.0..................................................................................................................................................12
4.1 Changes from V500R014C10SPC100 to 15.0.............................................................................................................12
4.1.1 Description................................................................................................................................................................12
4.2 Resolved Issues............................................................................................................................................................13
4.3 Known Issues................................................................................................................................................................14

5 V500R014C10SPC100..................................................................................................................17
5.1 Changes from V500R013C00U1 to V500R014C10SPC100.......................................................................................17
5.1.1 Description................................................................................................................................................................17
5.2 Resolved Issues............................................................................................................................................................24
5.3 Known Issue.................................................................................................................................................................27

6 Related Documentation..............................................................................................................28
6.1 15.0 Documentation.....................................................................................................................................................28
6.2 Obtaining Documentation............................................................................................................................................28
6.2.1 Support Website.........................................................................................................................................................28

A Third-Party Software Vulnerabilities Fix List......................................................................30


B Acronyms and Abbreviations...................................................................................................31

Issue 01 (2017-12-28) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

1 Version Requirements

This chapter describes the versions of the NE, other software, operating system (OS), and
database that match with OMStar 15.2.T1 and antivirus scanning results.

1.1 Product Version


Table 1.1 Product version
Product Name OMStar

Product Version 15.2.T1

1.2 Related Product Versions


Table 1.2 Related product versions
Product Version

RNC BSC6900 V900R014C00


BSC6910 V100R014C00
BSC6900 V900R015C00
BSC6910 V100R015C00
BSC6900 V900R015C01
BSC6910 V100R015C01
BSC6900 V900R016C00
BSC6910 V100R016C00

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

Product Version

BSC6900 V900R017C00
BSC6910 V100R017C00
BSC6900 V900R017C10
BSC6910 V100R017C10
BSC6900 V900R018C00
BSC6910 V100R018C00
BSC6900 V900R018C10
BSC6910 V100R018C10
BSC6900 V900R019C00
BSC6910 V100R019C00
BSC6900 V900R019C10
BSC6910 V100R019C10
BSC6900 V900R020C00
BSC6910 V100R020C00
BSC BSC6900 V900R014C00
BSC6910 V100R014C00
BSC6900 V900R015C00
BSC6910 V100R015C00
BSC6900 V900R015C01
BSC6910 V100R015C01
BSC6900 V900R016C00
BSC6910 V100R016C00
BSC6900 V900R017C00
BSC6910 V100R017C00
BSC6900 V900R017C10
BSC6910 V100R017C10
BSC6900 V900R018C00
BSC6910 V100R018C00
BSC6900 V900R018C10
BSC6910 V100R018C10
BSC6900 V900R019C00

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

Product Version

BSC6910 V100R019C00
BSC6900 V900R019C10
BSC6910 V100R019C10
BSC6900 V900R020C00
BSC6910 V100R020C00
NodeB BTS3900 V100R008C00
BTS3900 V100R008C01
BTS3900 V100R009C00
BTS3900 V100R010C00
BTS3900 V100R010C10
BTS3900 V100R011C00
BTS3900 V100R011C10
BTS3900 V100R012C00
BTS3900 V100R012C10
BTS3900 V100R013C00
DBS3900 WCDMA V200R014C00
BTS3803E WCDMA V200R014C00
BTS3803E WCDMA V200R015C00
BTS3803E WCDMA V100R009C00
BTS3902E WCDMA V100R009C00
BTS3902E WCDMA V100R011C00
BTS3902E WCDMA V100R011C10
BTS3902E WCDMA V100R012C00
BTS3902E WCDMA V100R012C10
EGBTS BTS3900 V100R008C00
BTS3900 V100R009C00
BTS3900 V100R010C00
BTS3900 V100R011C00
BTS3900 V100R011C10
BTS3900 V100R012C00
NB-IoT NB-IoT V100R012

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

Product Version

eNodeB eNodeB V100R005C00 (eRAN3.0)


eNodeB V100R005C01 (eRAN3.1)

BTS3900 V100R008C00 (eRAN6.0)

BTS3900 V100R008C01 (eRAN6.1)


BTS3900 V100R009C00 (eRAN7.0)
BTS3900 V100R010C00 (eRAN8.0)
BTS3900 V100R010C10 (eRAN8.1)
BTS3900 V100R010C10SPC225 (eRAN8.1)
BTS3900 V100R011C00 (eRAN11.0)
BTS3900 V100R011C10 (eRAN11.1)
BTS3900 V100R011C10SPC210 (eRAN11.1)
BTS3900 V100R012C00 (eRAN12.0)
BTS3900 V100R012C10 (eRAN12.1)
BTS3900 V100R013C00(eRAN13.0)
BTS5900 V100R012C10(eRAN12.1)
BTS5900 V100R013C00(eRAN13.0)
BTS3202E LTE V100R005C00 (eRAN3.0)

BTS3202E LTE V100R008C00 (eRAN6.0)


BTS3202E LTE V100R008C01 (eRAN6.1)
BTS3202E LTE V100R009C00 (eRAN7.0)
BTS3202E LTE V100R010C00 (eRAN8.0)
BTS3202E LTE V100R010C10 (eRAN8.1)
BTS3202E LTE V100R011C00 (eRAN11.0)
BTS3202E LTE V100R011C10 (eRAN11.1)
BTS3202E LTE V100R012C00 (eRAN12.0)
BTS3202E LTE V100R012C10 (eRAN12.1)
BTS3202B LTE V100R005C00 (eRAN3.0)
BTS3202B LTE V100R008C00 (eRAN6.0)
BTS3202B LTE V100R008C01 (eRAN6.1)
BTS3202B LTE V100R009C00 (eRAN7.0)
BTS3202B LTE V100R010C00 (eRAN8.0)

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

Product Version

BTS3202B LTE V100R010C10 (eRAN8.1)


BTS3202B LTE V100R011C00 (eRAN11.0)

BTS3202B LTE V100R011C10 (eRAN11.1)

BTS3202B LTE V100R012C00 (eRAN12.0)

BTS3202B LTE V100R012C10 (eRAN12.1)

BTS3203E LTE V100R009C00 (eRAN7.0)


BTS3203E LTE V100R010C00 (eRAN8.0)

BTS3203E LTE V100R010C10 (eRAN8.1)

BTS3203E LTE V100R011C00 (eRAN11.0)

BTS3203E LTE V100R011C10 (eRAN11.1)


BTS3203E LTE V100R012C00 (eRAN12.0)
BTS3203E LTE V100R012C10 (eRAN12.1)
BTS3205E LTE V100R011C00 (eRAN11.0)

BTS3205E LTE V100R011C10 (eRAN11.1)


BTS3205E LTE V100R012C00 (eRAN12.0)
BTS3205E LTE V100R012C10 (eRAN12.1)
BTS3911E LTE V100R011C00 (eRAN11.0)

BTS3911E LTE V100R011C10 (eRAN11.1)


BTS3911E LTE V100R012C00 (eRAN12.0)
BTS3911E LTE V100R012C10 (eRAN12.1)
BTS3911B LTE V100R011C00 (eRAN11.0)
BTS3911B LTE V100R011C10 (eRAN11.1)
BTS3911B LTE V100R012C00 (eRAN12.0)
BTS3911B LTE V100R012C10 (eRAN12.1)

Table 1.3 Other software version used with OMStar 15.2.T1


Software Version

iMAP iMAP V300R001C07

NOTE:

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

OMStar tool needed the NE maintenance personnel provided Parameter Check Template. The
current tool support template is as follows:

Table 1.4 NE Version supported for Parameter Check Template of OMStar tool
Product Version

RNC BSC6900 V900R014C00


BSC6900 V900R015C00
BSC6910 V100R015C00
BSC6900 V900R016C00
BSC6910 V100R016C00
BSC6900 V900R017C00
BSC6910 V100R017C00
BSC6900 V900R017C10
BSC6910 V100R017C10
BSC6900 V900R018C10
BSC6910 V100R018C10
BSC BSC6900 V900R014C00
BSC6900 V900R015C00
BSC6910 V100R015C00
BSC6900 V900R016C00
BSC6910 V100R016C00
BSC6900 V900R017C00
BSC6910 V100R017C00
BSC6900 V900R017C10
BSC6910 V100R017C10
BSC6900 V900R018C10
BSC6910 V100R018C10
eNodeB FDD eNodeB V100R005C00(eRAN3.0)
eNodeB V100R005C01(eRAN3.1)
BTS3900 V100R008C00(eRAN6.0)
BTS3900 V100R008C01(eRAN6.1)
BTS3900 V100R009C00(eRAN7.0)
BTS3900 V100R010C00(eRAN8.0)

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

Product Version

BTS3900 V100R010C10(eRAN8.1)
BTS3900 V100R011C10(eRAN11.1)
BTS3900 V100R012C00(eRAN12.0)(NB-IOT)
eNodeB TDD eNodeB V100R005C00(eRAN3.0)
eNodeB V100R005C01(eRAN3.1)

BTS3900 V100R008C00(eRAN6.0)

BTS3900 V100R008C01(eRAN6.1)
BTS3900 V100R009C00(eRAN7.0)
BTS3900 V100R010C10(eRAN8.1)
BTS3900 V100R011C00(eRAN11.0)
BTS3900 V100R011C10(eRAN11.1)

1.3 OS and Database Versions


Table 1.5 OS and database versions that match OMStar 15.2.T1
Recommended OS Version Database Office Specifications Remarks
Hardware Version Version
Configuration
Huawei mainstream Windows 7 PostgreSQL Office Seven-day 32-/64-bit
PC model: CPU 4 x (32-/64-bit) 9.3.6 2007 performance data of 1 Windows 7
Intel Core i5, 4 GB Windows 10 (installed by Office BSC (RNC) OS is the
memory default when 2013 3 x 6 busy hours mainstream
(32-/64-bit) installing the OS supported
CHR/MR data of 1
OMStar) BSC (RNC) by the
OMStar.
Seven-day
performance data of
250 eNodeBs
1 x 24 hours CHR
data of 30 eNodeBs

Table 1.6 The compatible OS and database with OMStar 15.2.T1


Recommended OS Database Office Specifications Remarks
Hardware Version Version Version
Configuration

HP DL380 Server Windows PostgreSQL Office 7 days performance The OMStar in

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

Recommended OS Database Office Specifications Remarks


Hardware Version Version Version
Configuration

and later versions: Server 9.3.6 2007 data of 1 to 3 BSCs the product line
CPU2 x 6 Xeon, 12 2003 (installed by Office (RNCs) positioning is the
GB memory (32-/64-bit) default when 2013 3 x 6 busy hours single plane tool.
Windows installing the CHR/MR data of 1 Therefore,
Server OMStar) BSC (RNC) Windows Server
2008 (64- 2003 is not the
7 days performance mainstream
bit) data of 250 eNodeBs operating system
1 x 24 hours CHR supported by
data of 30 eNodeBs OMStar 15.2.T1.
The OS is
compatible, but is
not
recommended.

1.4 Antivirus Scanning Results


This software package has been scanned by the McAfee, Symantec Endpoint Protection,
OfficeScan, Avira Antivirus, and Kaspersky antivirus software. No virus is detected. The
following tables list the detailed scanning results.

Table 1.6 McAfee scanning result


Antivirus Software Name McAfee

Antivirus Software Version 5800:7501

Virus Database Version 8571:0

Scanning Date 2017-06-27 09:30:10.038

Scanning Result OK

Table 1.7 Symantec Endpoint Protection scanning result


Antivirus Software Name Symantec

Antivirus Software Version 12.1.2015.2015


Virus Database Version 2017-06-26r2
Scanning Date 2017-06-27 09:28:29.886
Scanning Result OK

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version RequirementsVersion Requirements

Table 1.8 OfficeScan scanning result


Antivirus Software Name OSCE

Antivirus Software Version 9.850.1008


Virus Database Version 1349500
Scanning Date 2017-06-27 09:42:11.179
Scanning Result OK

Table 1.9 Avira Antivirus scanning result


Antivirus Software Name Avira
Antivirus Software Version 8.03.44.092
Virus Database Version 7.14.14.112
Scanning Date 2017-06-27 09:55:42.504
Scanning Result OK

Table 1.10 Kaspersky scanning result


Antivirus Software Name Kav

Antivirus Software Version 10.2.5.3201


Virus Database Version 20170627-061645
Scanning Date 2017-06-27 10:01:33.036
Scanning Result OK

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Version CompatibilityVersion Compatibility

2 Version Compatibility

2.1 Compatibility with Earlier Versions


Table 1.7 Compatibility between OMStar 15.1 and earlier versions
Product Version Release Date Compatibility Description

OMStar 15.1 2017-03-10 Compatible

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Important NotesImportant Notes

3 Important Notes

 Before using OMStar 15.0, verify that Microsoft Office 2007 or 2013 has been installed
on the local PC.
 You are advised not to open a .doc, .docx, .xls, or .xlsx document when a report is being
generated. Otherwise, the report may not be generated properly.
 You are advised not to copy and paste a report when the report is being generated,
ensuring that the report is generated properly.
 Before collecting data, you must obtain the written authorization from customers.
Standard authorization must include the products or issue items, purposes, contents,
scopes, time limits, and other stipulations.
 Before collecting data, you must obtain anonymized personal data at the NE side. Ensure
that collected data has been anonymized.
 According to data sources required for themes to be analyzed, data collection must
comply with the principle of minimum range collection.
 Data can only be used within the authorization scope and time limit. Data use must be
dedicated for a specified person, and records can be queried.
 You are advised not to transmit raw network data out of networks of security sensitive
countries and to China.
 After an analysis task is complete, yon need to immediately delete raw data and OMStar
projects. Saving raw data or backing up the database is not allowed. Delete the project in
the Project Manager window.
 You are advised to use the 64-bit OMStar. Big data may fail to be imported and analyzed
on the 32-bit OMStar.
 To protect user privacy, you must collect anonymized personal data from source devices.
The OMStar provides a password authorization mechanism for data access and displays
scrambled personal data.
 The OMStar can export or save analysis results. Export the analysis results of features
containing personal data with caution. Ensure that the exported analysis results are only
used for network problem analysis. By default, the OMStar exports scrambled analysis
results.
 The OMStar is a Huawei internal tool. Therefore, it should not be released to, introduced
to, and recommended to customers. This document is only for internal use.
 The OMStar is a stand-alone tool. Therefore, the OS and antivirus software are not
contained in the released software. You need to periodically update the security patches
of the OS and antivirus software.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Important NotesImportant Notes

 The OMStar collects statistics about the use of each service feature and function to learn
each service function and tool performance, facilitating tool optimization. The following
information is collected: ESN of the PC, feature startup time, feature end time, feature
ID, subfeature ID, running status, and user name (domain account). Collected
information is not the data from customers' networks. If the script update function is
enabled, the OMStar automatically performs the feature statistics function and uploads
the results to the feature statistics server.

3.1 Impact of the Anonymous Policy on OMStar Features


Impact of the MSISDN Anonymization Policy on Fuzzy Search
The MSISDN anonymization policy affects NDC-based analysis and MSISDN-based fuzzy
search. NDC is short for national destination code.
An example is described as follows: With MSISDN-based fuzzy search, users can obtain
8613612345678 and 13612345678 by entering 136. However, after being scrambled, the
preceding numbers might become E806AABCE0B44EC25128DB and
3698FD5BC48C1E36BEBE64 which have nothing in common.
Affected features are CHR browsing and signaling browsing.

Collision Possibility of the IMEI Anonymization Policy


The IMEI anonymization policy is used to anonymize 6 to 8 digits excluding the IMEI TAC
of an IMEI. It allows the OMStar to compress an 8-digit code into a 4-byte code and obtain a
resulting HASH 32-byte code using the HMAC-SHA256 algorithm. Then, the OMStar takes
and decodes the preceding 4 bytes as the anonymization result.
In theory, collisions are possible because obtained HASH codes are one eighth of the original
codes in length. A collision occurs if two different 8-digit numbers are converted into the
same new 8-digit hexadecimal number after they are anonymized. Based on laboratory data,
the probability of collisions is approximately 0.012%.
Two different IMEIs might be regarded as the same IMEI in the statistical results if their IMEI
TACs are the same. This affects the accuracy of terminal analysis results.
Affected features are call drop in-depth analysis, access failure in-depth analysis, signaling
browsing, and CHR browsing.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.2.T115.2.T1

4 15.2.T1

4.1 Changes from 15.1 to 15.2.T1


4.1.1 Description
Compared with those in 15.1, the following features are updated in OMStar 15.2.T1.

Modified Features
The following features are modified in OMStar 15.2.T1:
2. OMSTAR 支持网元 GU 20.0 版本配套需求

Table 1.1 网元版本适配


Feature Name 网元版本适配
Description OMSTAR 支持网元 GU 20.0 版本配套需求

Implementation 平台数据库中网元适配表刷新,配套 GU 20.0

Operation 1. 启动 OMStar;
2. 导入配置、话统数据。
Feature ID IREQ02124371

Deleted Feature
No feature is deleted in OMStar 15.2.T1.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.2.T115.2.T1

4.2 Resolved Issues


3. [DTS2017041004373] 【工程升级】R13 GA 版本新建工程,不卸载数据库,升级到
V5R14C10 版本,原有工程无法打开;且 R14 版本没有 CHRMR 数据导入口,导
致任务无法执行.

Table 1.1 工程升级


Trouble Ticket DTS2017041004373
Number

Description 【工程升级】R13 GA 版本新建工程,不卸载数据库,升


【OLD】
级到 V5R14C10 版本,原有工程无法打开;且 R14 版本没有
CHRMR 数据导入口,导致任务无法执行。
Severity 严重
Workaround 卸载工具时选择卸载数据库,安装时选择安装数据库
Impact 需要重新创建任务进行分析

4. [DTS2017083103279]【MOD】
【自动化】 【UMTS KPI 分析】相同数据相同操
【X64】
作,不同转测包结果不同.

Table 1.1 相同数据相同操作,不同转测包结果不同


Trouble Ticket DTS2017083103279
Number

Description 【MOD】
【自动化】
【X64】
【UMTS KPI 分析】相同数据相同操作,不
同转测包结果不同.
Severity 一般
Workaround 采集数据时,需要保持采集的指标在制定范围内恒定,或者将
有差异的指标范围数据分开分析
Impact KPI 分析

5. [DTS2017082905061]【MOD】
【自动化】 【LTE KPI 专题】使用 NB-IOT 数据,
【X64】
默认任务,B002 包解析结果比 B001 包多了两行.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.2.T115.2.T1

Table 1.1 使用 NB-IOT 数据,默认任务,B002 包解析结果比 B001 包多了两行


Trouble Ticket DTS2017082905061
Number

Description 【MOD】
【自动化】 【LTE KPI 专题】使用 NB-IOT 数据,默
【X64】
认任务,B002 包解析结果比 B001 包多了两行。
Severity 一般
Workaround 采集数据时,需要保持采集的指标在制定范围内恒定,或者将
有差异的指标范围数据分开分析
Impact KPI 分析

4.3 Known Issues


None

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.115.1

5 15.1

5.1 Changes from 15.0 to 15.1


5.1.1 Description
Compared with those in OMStar 15.0, the following features are updated in OMStar 15.1.

New Features
The following features are added in OMStar 15.1:
6. eRAN13.0 数据源适配(压缩 SIG )

Table 1.1 数据导入


Name 数据导入
Description OMStar 支持 SIG 数据源(压缩 SIG)适配

Implementation 数据处理时新增.sig.gz 格式

Operation 1. SIG 浏览的时,支持的文件种类中增加.sig.gz 格式的 SIG 数据


2. BinCoder 在解析 SIG 数据时,支持 sig.gz 直接读取
3. SIG 数据导入时,支持的文件种类中增加.sig.gz 格式的 SIG 数

Feature ID IREQ02090984

7. OMStar 需要支持 eRAN11.1 及更高版本的非 normal 类型 cellric CHR 解析

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 16


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.115.1

Table 1.1 OMStar 需要支持 eRAN11.1 及更高版本的非 normal 类型 cellric CHR 解析


Name 数据导入
Description OMStar 需要支持 eRAN11.1 及更高版本的非 normal 类型 cellric
CHR 解析
Implementation FFTSIZE 为非 2 的 n 次幂且不等于 1536,其中 1)和 2)是已经支
持的场景,对于新增的增强压缩类型,比如带宽为 10M,CRPI 为
增长压缩,FFTSIZE = 1280 则属于场景 3),按照场景 3 算法分支
进行解析处理,场景 3 分支使用开源的 breeze 包中的 fft 计算是支
持任意基的 FFT 变换
Operation 支持三种不同情况,1) FFTSIZE 为 2 的 n 次幂
支持三种不同情况,2)FFTSIZE 为 1536
支持三种不同情况,3)FFTSIZE 为非 2 的 n 次幂且不等于 1536,
其中 1)和 2)是已经支持的场景,对于新增的增强压缩类型,比
如带宽为 10M,CRPI 为增长压缩,FFTSIZE = 1280 则属于场景
3),按照场景 3 算法分支进行解析处理,场景 3 分支使用开源的
breeze 包中的 fft 计算是支持任意基的 FFT 变换
Feature ID IREQ02090986

Modified Features
The following features are modified in OMStar V500R014C10SPC100:
1. OMSTAR 支持 SRN12.1/SRAN 13.0 版本适配支持 BTS5900 配套需求

Table 1.1 网元版本适配


Feature Name 网元版本适配
Description OMSTAR 支持 SRN12.1/SRAN 13.0 版本适配支持 BTS5900 配套需

Implementation 平台数据库中网元适配表刷新,配套 SRN12.1/SRAN 13.0

Operation 1. 启动 OMStar;
2. 导入配置、话统数据。
Feature ID IREQ02090985

Deleted Feature
No feature is deleted in OMStar 15.0.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 17


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.115.1

5.2 Resolved Issues


2. [DTS2017042403608] 【Win10/office2013】【版本兼容】首次安装工具,执行任务时
强制关闭,重启要重新域鉴权.

Table 1.1 Win10/office2013 环境上强制关闭工具,重启要重新域鉴权


Trouble Ticket DTS2017042403608
Number

Description 【Win10/office2013】【版本兼容】首次安装工具,执行任务时强
制关闭,重启要重新域鉴权
Severity Minor

Workaround 重新预鉴权就可以再次打开工具
Impact 需要用户重新域鉴权

3. [DTS2017041009188] 【LTE 邻区核查】执行 LTE 邻区核查任务时选项设为 LTE-


>LTE(单邻区核查),性能不达标(性能基线为 10 分,R14 结果为 33 分 1 秒).

Table 1.1 LTE 邻区核查,执行 LTE 邻区核查任务性能不达标


Trouble Ticket DTS2017041009188
Number

Description 【OLD】【X64】
【性能】 【LTE 邻区核查】执行 LTE 邻区核查任务
时选项设为 LTE->LTE(单邻区核查),性能不达标(性能基
线为 10 分,R14 结果为 33 分 1 秒).
Severity Minor

Workaround 功能增加逻辑控制标识,区分两种场景的逻辑.

Impact 功能分析时间变长

5.3 Known Issue


4. [DTS2017041004373] [Project Upgrade] The project created in OMStar V500R013 GA
cannot be opened in OMStar V500R014C10 after the upgrade.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 18


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.115.1

Table 1.1 Project upgrade


Trouble Ticket DTS2017041004373
Number

Description A user creates a project in OMStar V500R013 GA and installs


OMStar V500R014C10 without uninstalling the old database. After
the upgrade, the created project cannot be opened. In addition, no
portal for importing CHR and MR data is available. As a result,
analysis tasks cannot be executed.
Severity Major

Workaround Uninstall the old database during installation of OMStar


V500R014C10.
Impact Existing projects from OMStar V500R013 cannot be used, and the
user needs to create projects in OMStar V500R014C10.

5. [DTS2017083103279]【MOD】
【自动化】 【UMTS KPI 分析】相同数据相同操
【X64】
作,不同转测包结果不同。

Table 1.1 [LTE Neighboring Cell Check] Total number of result records not updated
Trouble Ticket DTS2017083103279
Number

Description 【MOD】
【自动化】 【UMTS KPI 分析】相同数据相同操作,
【X64】
不同转测包结果不同.
Severity 一般
Workaround 采集数据时,需要保持采集的指标在制定范围内恒定,或者将
有差异的指标范围数据分开分析
Impact KPI 分析

6. [DTS2017082905061]【MOD】
【自动化】 【LTE KPI 专题】使用 NB-IOT 数据,
【X64】
默认任务,B002 包解析结果比 B001 包多了两行.

Table 1.1 Invalid LOCELL object groups selected in UMTS KPI Analysis
Trouble Ticket DTS2017082905061
Number

Description 【MOD】
【自动化】 【LTE KPI 专题】使用 NB-IOT 数据,默
【X64】
认任务,B002 包解析结果比 B001 包多了两行。
Severity 一般
Workaround 采集数据时,需要保持采集的指标在制定范围内恒定,或者将
有差异的指标范围数据分开分析
Impact KPI 分析

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 19


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes 15.115.1

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 20


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Related DocumentationRelated Documentation

6 Related Documentation

6.1 15.0 Documentation


Table 1.1 Related documentations
Name Introduction Delivery Form

OMStar 15.2.T1 This document describes how to install Electronic


Installation Guide OMStar 15.2.T1 and instruct Huawei documents
service engineers to complete the
installation correctly.
OMStar 15.2.T1 User This document describes how to use the Electronic
Manual features and functions of OMStar 15.2.T1 documents
instruct Huawei service engineers to
correctly use the tool to complete the task
analysis.

6.2 Obtaining Documentation


6.2.1 Support Website
You can view or download related documentation at http://support.huawei.com.

You must apply for permissions to obtain documentation from the website. If you visit
http://support.huawei.com for the first time, register with the website.

Registering with the Website


To register with http://support.huawei.com, perform the following steps:
Step 2 Access http://support.huawei.com.
Step 3 Click Register, and follow the instructions to complete the registration process.

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 21


Copyright © Huawei Technologies Co., Ltd.
OMStar 15.2.T1
Release Notes Related DocumentationRelated Documentation

If your registration is successful, you will be informed of your user name and password within
two or three working days.
----End

Viewing or Downloading Documentation


To view or download documentation from http://support.huawei.com, perform the following
steps:
Step 1 Access http://support.huawei.com.
Step 2 Click Log In.
In the displayed dialog box, enter the user name, password, and verification code and click
Login.
Step 3 After a successful login, choose Support > Software > Global Service > System
Integration Service > Mobile Network Integration Service > OMStar in the Product
Version pane.
Step 4 Select the different product versions, and enter the corresponding pages to download the
documents.

 You can also enter the product name in the Product Name text box on the home page of
http://support.huawei.com to search for documents specific to a product.
 If the file name extension of a documentation package is in .hdx format, use HedEx Lite to view the
documents. You can obtain the software from Huawei customer service engineers.

----End

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 22


Copyright © Huawei Technologies Co., Ltd.
OMStar A Third-Party Software Vulnerabilities Fix ListRelated
Release Notes Documentation

A Third-Party Software Vulnerabilities Fix


List

The OMStar is the software developed by Huawei and used by Huawei engineers, and it is not
sold to customers. The third-party software vulnerabilities fix list is as follows.

Software Version CVE Description Solution


Number

Apache 1.9.1 CVE- Apache Commons BeanUtils, as The OMStar


Jakarta 2014-0114 distributed in lib/commons- is an offline
Commons beanutils-1.8.0.jar in Apache Struts standalone
BeanUtils 1.x through 1.3.10 and in other software
products requiring commons- product. It is
beanutils through 1.9.2, does not not involved
suppress the class property, which in remote
allows remote attackers to attack, so it is
manipulate" the ClassLoader and not affected
execute arbitrary code via the class by this
parameter, as demonstrated by the vulnerability.
passing of this parameter to the
getClass method of the ActionForm
object in Struts 1."

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 23


Copyright © Huawei Technologies Co., Ltd.
OMStar A Third-Party Software Vulnerabilities Fix ListRelated
Release Notes Documentation

B Acronyms and Abbreviations

BSC base station controller


eNodeB E-UTRAN NodeB
RNC radio network controller

Issue 01 (2017-12-28) Huawei Proprietary and Confidential 24


Copyright © Huawei Technologies Co., Ltd.

Vous aimerez peut-être aussi