Appendix 8
List of national and international standards relating to power
transformers
Appendix 8
transformers*
IEC 60076-14: Power transformers:
Part 14 – Guide for the design and
application of liquid-immersed power
transformers using high temperature
951
insulation materials*
952
International Standards European Standards UK National Standards
IEC 60076-15: Power transformers:
Appendix 8
Part 15 – Gas-filled-type power transformers*
IEC 60214-1: Tap-changers: EN 60214-1: Tap-changers: BS EN 60214-1: Tap-changers:
Part 1 – Performance requirements Part 1 – Performance requirements Part 1 – Performance requirements and
and test methods and test methods test methods
IEC 60214-2: Tap-changers: Not harmonised BS 5611: Application guide for
Part 2 – Application guide on-load tapchangers
IEC 60289: Reactors EN 60289: Reactors BS EN 60289: Reactors
IEC 60354: Loading guide for oil-immersed Not harmonised BS 7735: Guide to loading of
transformers oil-immersed power transformers
IEC 60071-1: Insulation co-ordination: EN 60071-1: Insulation BS EN 60071-1: Insulation
Part 1 – Definitions, principles and rules co-ordination: Part 1 – Definitions, co-ordination: Part 1 – Definitions,
principles and rules principles and rules
IEC 60071-2: Insulation co-ordination: EN 60071-2: Insulation BS EN 60071-2: Insulation
Part 2 – Application guide co-ordination: Part 2 – Application co-ordination: Part 2 – Application
guide guide
IEC 60099-5: Surge arresters: EN 60099-5: Surge arresters: BS EN 60099-5: Surge arresters:
Part 5 – Selection and application Part 5 – Selection and application Part 5 – Selection and application
recommendations recommendations recommendations
IEC 60137: Insulated bushings for alternating EN 60137: Insulated bushings for BS EN 60137: Insulated bushings for
voltages above 1000 V alternating voltages above 1000 V alternating voltages above 1000 V
European Standards UK National Standards
HD 428.1 (1992): Three-phase oil-immersed distribution BS 7821: Part 1 – 1995 Three-phase oil-immersed distribution
transformers: Part 1 – General requirements and transformers: Part 1 – General requirements and requirements
requirements for transformers with highest voltage for transformers with highest voltage for equipment not
for equipment not exceeding 24 kV exceeding 24 kV
HD 428.2.1 (1994): Three-phase BS 7821: Part 2 – Section 2.1 1995 Three-phase
oil-immersed distribution transformers: oil-immersed distribution transformers:
Part 2.1 – Distribution transformers with cable Part 2.1 – Distribution transformers with cable boxes on
boxes on the high voltage and/or the low voltage the high voltage and/or the low voltage
side. General requirements side. General requirements
Part 2.2 – Distribution transformers with Part 2.2 – Distribution transformers with cable boxes on
cable boxes on the high voltage and/or the low the high voltage and/or the low voltage side. Cable
voltage side. Cable boxes type 1 boxes type 1
Part 2.3 – Distribution transformers with cable Part 2.3 – Distribution transformers with cable boxes on
boxes on the high voltage and/or the low voltage side. the high voltage and/or the low voltage side. Cable boxes type 2
Cable boxes type 2
HD 428.3 (1994): Supplementary requirements BS 7821: Part 3 – 1995 Supplementary requirements for
for transformers with highest voltage for transformers with highest voltage for equipment
equipment equal to 36 kV equal to 36 kV
Appendix 8
HD 428.4 (1994): Determination of the BS 7821: Part 4 – 1995 Determination of the power rating
power rating of a transformer loaded with of a transformer loaded with non-sinusoidal currents
non-sinusoidal currents
HD 428.6 (2002): Requirements and BS 7821: Part 6 – 2002: Requirements and tests
tests concerning pressurised corrugated tanks concerning pressurised corrugated tanks
953
954
European Standards UK National Standards
Appendix 8
HD 538.1 (1992): Three phase dry-type BS 7844: Part 1 – 1996: Three phase dry-type
distribution transformers: Part 1 – General distribution transformers: Part 1 – General requirements and
requirements and requirements for transformers with requirements for transformers with highest voltage for
highest voltage for equipment not exceeding 24 kV equipment not exceeding 24 kV
HD 538.2 (1995): Supplementary requirements BS 7844: Part 2 – 1996: Supplementary requirements for
for transformers with highest voltage for equipment transformers with highest voltage for equipment equal
equal to 36 kV to 36 kV
HD 538.3 (1998): Determination of the power rating BS 7844: Part 3 – 1998: Determination of the power rating
of a transformer loaded with non-sinusoidal current of a transformer loaded with non-sinusoidal current
EN 50195 (1996): Code of practice for the safe BS EN 50195 (1997): Code of practice for the safe
use of askerel filled electrical equipment use of askerel filled electrical equipment
EN 50225 (1996): Code of practice for the BS EN 50225 (1997): Code of practice for the safe use
safe use of fully enclosed oil-filled electrical of fully oil-filled electrical equipment which may contain PCBs
equipment which may contain PCBs BS 2562 (1979): Cable boxes for transformers and reactors
BS 6435 (1984): Unfilled enclosures for the dry termination
of HV cables for transformers and reactors
BS 6436 (1984): Ground mounted distribution transformers
for cable box or unit substation connection
* Extracts from British and International Standards are reproduced with permission. Complete editions of the standards can be obtained by post from BSI Customer
Services, 389 Chiswick High Road, London W4 4AL, UK. Telephone: +44 (0)20 8996 7000, facsimile: +44(0)20 8996 7001.
Appendix 8 955