Huawei RH V3 Series Rack Servers

Introduction

Huawei RH V3 Series
Rack Servers
Introduction

www.huawei.com

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved.

Objectives

 Upon completion of this course, you will be proficient in:

 RH series servers

 Installation of key components for RH series servers

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page1

啊啊 1
Huawei RH V3 Series Rack Servers
Introduction

Contents

 RH Series Server Overview and Positioning

 RH Series Server Description

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page2

Huawei Rack Server Family

1U 2-socket 2U 2-socket 2U 4-socket 4U 4-socket 8U 8-socket


server server server server server

RH1288 V2 RH2285 V2 RH2485 V2 RH5885 V2-4-socket


RH2288 V2 RH5885 V2-8-
RH2285H V2 socket
RH2288H V2
RH2288E V2

RH1288 V3 RH2288 V3 RH5885 V3 RH8100 V3


RH2288H V3 RH5885H V3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page3

啊啊 2
Huawei RH V3 Series Rack Servers
Introduction

Huawei Rack Server Series

RH8100 V3
(E7-8800 v2)
RH5885H V3
RH5885 V3
RH2485 V2
(E5-4600 v2) (E7-4800 v2)

RH2288H V3
RH1288 V3 RH2288 V3 (E5-2600 v3)
(E5-2600 v3)
(E5-2600 v3) 5288 V3
(E5-2600 v3)

RH1288 V2
(E5-2600 v2)
RH2288H V2
RH2285H V2 RH2288A V2 (E5-2600 v2)
(E5-2600 v2)
RH1288A V2 (E5-2400 v2)
(E5-2600 v2)

4U2P 2U4P 4U4P 8U8P


1U2P server 2U2P server
server server server server

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page4

Server Positioning
High

The high-end 8-socket rack server is designed for mission-critical


RH8100 V3 business, in-memory databases, virtualization, and HPC.

The 4U 4-socket enterprise-level rack server is ideal for databases,


RH5885 V2/3 virtualization, and in-memory computing.

The 2U 2-socket rack server features high performance and scalability,


RH2288 V2/3 and is the most widely used 2U server.

The economical 2U 2-socket rack server meets requirements for IT


RH2285 V2/3 infrastructure and ultra-large local storage applications.

The compact 1U 2-socket rack server provides high computing density


RH1288 V2/3 and large memory capacity in 1U space, which is suitable for dense
computing applications.
Low

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page5

啊啊 3
Huawei RH V3 Series Rack Servers
Introduction

Contents

 RH Series Server Overview and Positioning


 RH Series Server Description
 RHx2xx(H) V3
 5288 V3
 RH5885 V3
 RH8100 V3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page6

RH1288 V3 Technical Specifications

Front view Form factor 1U 2-socket rack server


Number of 1 or 2
processors
Processor Intel Xeon E5-2600 v3 or v4 series processors
Memory 16 DDR4 RDIMMs/LRDIMMs

Internal storage 8 x 2.5-inch SAS/SATA HDDs or SSDs, or 4 x 3.5-inch SAS/SATA HDDs


Flash storage: dual SATA DOMs and dual SD cards

RAID 0, 1, 10, 5, 50, 6, and 60


2 GB RAID cache
RAID support Optional iBBU or supercapacitor
RAID state migration, configuration memory, self-diagnosis, and web-
based remote configuration

PCIe expansion Up to 2 PCIe slots Q(2


LOM network 2 or 4 x GE ports, or 2 x 10GE ports
port

2 hot-swappable PSUs in 1+1 redundancy mode:


Rear view • 460 W/750 W AC/DC PSUs
PSU • 800 W –48 V DC PSUs
• 1200 W HV DC PSUs

Fan module 5 hot-swappable fan modules in N+1 redundancy mode


Operating 5°C–45°C (41°F–113°F)
temperature Q(9
Chassis with 3.5-inch hard disks: 447 mm x 750 mm x 43.6 mm (17.60 in.
Dimensions (H x x 29.53 in. x 1.72 in.)
W x D) Chassis with 2.5-inch hard disks: 447 mm x 710 mm x 43.6 mm (17.60 in.
x 27.95 in. x 1.72 in.)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page7

啊啊 4
Slide 8

Q(2 从产品手册看只有2个PCIe
Qibinbin (Robin), 6/8/2016

Q(9 工作温度统㇐刷到45
Qibinbin (Robin), 6/8/2016
Huawei RH V3 Series Rack Servers
Introduction

RH2288 V3 Technical Specifications

Front view Form factor 2U 2-socket rack server


Number of 1 or 2
processors
Processor Intel Xeon E5-2600 v3 or v4 series processors
Memory 16 DDR4 RDIMMs/LRDIMMs

8 or 25 x 2.5-inch SAS/SATA HDDs or SSDs, or 10 or 12 x 3.5-inch


Internal storage SATA HDDs
Built-in flash storage: dual SATA DOMs and dual SD cards

RAID 0, 1, 10, 5, 50, 6, and 60


2 GB RAID cache
RAID support Optional iBBU or supercapacitor
RAID state migration, configuration memory, self-diagnosis, and web-
based remote configuration

PCIe expansion Up to 6 PCIe slots

LOM network 2 or 4 x GE electrical ports, supporting NC-SI, WOL, and PXE


Rear view port 2 x 10GE optical ports, supporting NC-SI and PXE
2 x 10GE electrical ports, supporting NC-SI, WOL, and PXE
PSU 2 hot-swappable PSUs in 1+1 redundancy mode
Fan module 4 hot-swappable fan modules in N+1 redundancy mode
Operating 5°C–45°C (41°F–113°F)
temperature
Chassis with 3.5-inch hard disks: 447 mm x 748 mm x 86.1 mm (2U)
Dimensions (H x (17.60 in. x 29.45 in. x 3.39 in.)
W x D) Chassis with 2.5-inch hard disks: 447 mm x 708 mm x 86.1 mm (2U)
(17.60 in. x 27.87 in. x 3.39 in.)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page8

RH2288H V3 Technical Specifications


Front view Form factor 2U 2-socket rack server
Number of 1 or 2
processors
Processor Intel Xeon E5-2600 v3 or v4 series processors
Memory 24 DDR4 RDIMMs/LRDIMMs
Internal 8 or 25 x 2.5-inch SAS/SATA HDDs or SSDs, or 10 or 12 x 3.5-
storage inch SATA HDDs
Built-in flash storage: dual SATA DOMs and dual SD cards
RAID 0, 1, 10, 5, 50, 6, and 60
2 GB RAID cache
RAID support Optional iBBU or supercapacitor
RAID state migration, configuration memory, self-diagnosis,
and web-based remote configuration
PCIe Up to 9 PCIe slots
expansion

LOM network 2 or 4 x GE electrical ports, supporting NC-SI, WOL, and PXE


Rear view port 2 x 10GE optical ports, supporting NC-SI and PXE
2 x 10GE electrical ports, supporting NC-SI, WOL, and PXE
PSU 2 hot-swappable PSUs in 1+1 redundancy mode
Fan module 4 hot-swappable fan modules in N+1 redundancy mode
Operating 5°C–45°C (41°F–113°F)
temperature
Chassis with 3.5-inch hard disks: 447 mm x 748 mm x 86.1
Dimensions (H mm (2U) (17.60 in. x 29.45 in. x 3.39 in.)
x W x D) Chassis with 2.5-inch hard disks: 447 mm x 708 mm x 86.1
mm (2U) (17.60 in. x 27.87 in. x 3.39 in.)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page9

啊啊 5
Huawei RH V3 Series Rack Servers
Introduction

RH2288H V3 Logical Architecture

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page10

RH2288 V3/RH2288H V3 Front View

 The RH2288 V3 supports five types of hard disk configurations:

8 x 2.5-inch hard disks

24 x 2.5-inch hard disks

25 x 2.5-inch hard disks

12 x 3.5-inch hard disks

10 x 3.5-inch hard disks

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page11

啊啊 6
Huawei RH V3 Series Rack Servers
Introduction

Front View of the RH2288 V3 with 8 Hard


Disks

1 Fault diagnosis LED 2 Health status indicator


3 UID button/indicator 4 Power button/indicator
5 VGA port 6 NMI button
7 Customer information label 8 Built-in DVD-ROM drive
9 Hard disks (slots numbered 0 to 7 from 10 Hard disk active indicator
top to bottom and from left to right)
11 Hard disk fault indicator 12 USB 2.0 port
13 Ethernet port indicator 4 14 Ethernet port indicator 3
15 Ethernet port indicator 2 16 Ethernet port indicator 1

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page12

Rear panel of the RH2288 V3

1 PSU 2 PSU indicator


3 Power socket of a PSU 4 I/O module 2
5 Connection status indicator 6 Data transmission status indicator
7 Onboard standard PCIe slot 8 I/O module 1
9 I/O NIC 10 UID indicator
11 USB 3.0 port 12 Management network port (Mgmt)
13 VGA port 14 Serial port

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page13

啊啊 7
Huawei RH V3 Series Rack Servers
Introduction

Rear view of an RH2288H V3

1 PSU 2 PSU indicator


3 Power socket of a PSU 4 I/O module 2
5 Connection status indicator 6 Data transmission status indicator
7 Onboard standard PCIe slot 8 I/O module 1
9 NIC 10 UID indicator
11 USB 3.0 port 12 Management network port (Mgmt)
13 VGA port 14 Serial port

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page14

RH2288 V3/RH2288H V3 Rear View

8 or 10 x front hard disks

12 or 24 x front hard disks

25 x front hard disks

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page15

啊啊 8
Huawei RH V3 Series Rack Servers
Introduction

RH2288H V3 Internal Structure


2 x Intel Haswell-EP
2 x PCIe 3.0 x8 slots E5-2600 v3/v4series
processors

RAID controller
card

Rear hard disk

PSUs in 1+1 4 x Fan modules Q(10


redundancy 24 x DDR3 DIMMs
mode

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page16

Specification Comparison Among Three Rack


Servers
Server Type RH1288 V3 RH2288 V3 RH2288H V3
CPU 2 x E5-2600 v3/v4 2 x E5-2600 v3/v4 2 x E5-2600 v3/v4
DIMM Slots 16 16 24
12*3.5SATA/SAS+4*3.5/4*2.5S 12*3.5SATA/SAS+4*3.5/4*2.5
ATA/SAS or SATA/SAS or
HDD 8 x 2.5" HDDs or 4 x 3.5"
25*2.5SATA/SAS+3*3.5/3*2.5S 25*2.5SATA/SAS+3*3.5/3*2.5
Configuration HDDs
ATA/SAS or 8 x 2.5"HDDs or 10 SATA/SAS or 8 x 2.5"HDDs or
x 3.5"HDDs 10 x 3.5"HDDs
Networking
2 x GE or 4 x GE or 2 x 10GE 2 x GE or 4 x GE or 2 x 10GE 2 x GE or 4 x GE or 2 x 10GE
on board
USB Ports 5(2 front, 2 back, 1 internal) 5(2 front, 2 back, 1 internal)5(2 front, 2 back, 1 internal)
9 PCIe 3.0(4 PCIe x8 FHFL or 2
6 PCIe 3.0(1 PCIe x8 FHHL ,1
PCIe x16 FHFL, 2 PCIe x8
PCIe Slots 2Q(16
PCIe 3.0 PCIe x8, 2 PCIe x8 FHFL, 2
FHFL, 2 lowprofile x8, 1 for
lowprofile x8, 1 for RAID)
RAID)
Support for vMedia, KVM, Support for vMedia, KVM,
Support for vMedia, KVM, and
and SOL;Compatible with and SOL;Compatible with
SOL;Compatible with IPMI 2.0,
System IPMI 2.0, SNMP, and IPMI 2.0, SNMP, and
SNMP, and IPv6;Support for
Management IPv6;Support for Huawei IPv6;Support for Huawei
Huawei eSight and third-party
eSight and third-party eSight and third-party
management software
management software management software

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page17

啊啊 9
Slide 17

Q(10 CPU描述改成风扇
Qibinbin (Robin), 6/8/2016

Slide 18

Q(16 2个PCIe
Qibinbin (Robin), 6/10/2016
Huawei RH V3 Series Rack Servers
Introduction

Contents

 RH Series Server Overview and Positioning


 RH Series Server Description
 RHx2xx(H) V3
 5288 V3
 RH5885 V3
 RH8100 V3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page18

5288 V3 Technical Specifications

Front view Form factor 4U 2-socket rack server


Number of
1 or 2
processors

Processor Intel Xeon E5-2600 v3/v4 series processors

Memory 8 or 16 DDR4 DIMMs/LRDIMMs

•36 x 3.5-inch + 2/4 x 2.5-inch or 3.5-inch hard disks


•24 x 3.5-inch + 2/4 x 2.5-inch or 3.5-inch hard disks
Internal storage
•2 x mini SSDs (SATA DOMs) grouped as a RAID 1 array for
the operating system (OS)

RAID 0, 1, 10, 5, 50, 6, and 60


RAID support
Optional supercapacitor
Rear view PCIe expansion Up to 6 PCIe slots

LOM network
2 or 4 x GE ports, or 2 x 10GE ports
port
PSU Two hot-swappable PSUs in 1+1 redundancy mode
Fan module Efficient fan modules in N+1 redundancy mode
Operating
5°C–40°C
temperature

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page19

啊啊 10
Huawei RH V3 Series Rack Servers
Introduction

5288 V3 Logical Structure

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page20

5288 V3 Internal Structure


1 Rear hard disk module
2 I/O module 2 (corresponding to
processor 2)
3 PSUs 4 LOM
5 PCIe card
6 RAID controller card
7 TPM (optional)
8 DIMMs
9 Heat sinks
10 Processors
11 Mainboard
12 PSU backplane
13 Hard disks
14 Rear hard disk backplane for 12
disks
15 Chassis
16 Air duct
17 Fan modules
18 Front hard disk backplane

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page21

啊啊 11
Huawei RH V3 Series Rack Servers
Introduction

5288 V3 Front View

1 Ethernet port indicator 2 USB 2.0 port


3 Hard disk fault indicator 4 Hard disk active indicator
5 Hard disk 6 Fault diagnosis LED
7 Healthy indicator 8 UID button/indicator
9 Power button/indicator

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page22

5288 V3 Rear View

Q(1
1 Rear hard disk 2 Hard disk fault indicator
3 Hard disk active indicator 4 I/O module
5 PSU port 6 PSU indicator
7 PSU 8 Serial port
9 VGA port 10 Management network port (Mgmt)
11 USB 3.0 port 12 UID indicator
13 PCIe slot 14 Connectivity status indicator
15 Data transmission status indicator 16 Service network port
17 Rear hard disk

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page23

啊啊 12
Slide 24

Q(1 图表说明不对
Qibinbin (Robin), 6/8/2016
Huawei RH V3 Series Rack Servers
Introduction

5288 V3 Expansion Modules

Two expansion modules Optional expansion modules

 Hard disk expansion


module (two hard
disks)

 PCIe module with three


PCIe slots

 PCIe module with


two PCIe slots

 Choose expansion modules based on service requirements, which improves flexibility


and maximizes ROI.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page24

Contents

 RH Series Server Overview and Positioning


 RH Series Server Description
 RHx2xx(H) V3
 5288 V3
 RH5885 V3
 RH8100 V3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page25

啊啊 13
Huawei RH V3 Series Rack Servers
Introduction

RH5885 V3 Technical Specifications

Front view Form factor 4U 4-socket rack server


Number of 2 or 4
processors

Processor Intel® Xeon® E7-4800/8800 v2/v3 series processors


Core options: 6, 8, 10, 12, 15 and 18 Q(7
Memory 48 DDR3 /DDR4 DIMMs Q(11
Maximum memory capacity: 1.5 TB
8 or 23 x 2.5-inch SAS/SATA HDDs or SSDs
Internal storage Four hard disks can be directly connected to the hard disk
backplane through the PCH.
RAID 0, 1, 10, 5, 50, 6, and 60
RAID support 1 GB RAID cache
Optional iBBU or supercapacitor for power-on protection
PCIe expansion Up to 7 PCIe slots
LOM network 2 or 4 x GE ports, or 2 x 10GE ports
port
Rear view
PSUs in 1+1 or 2+2 redundancy mode:
PSU 220 V or 110 V AC PSUs
–48 V DC PSUs

Fan module 5 hot-swappable fan modules in N+1 redundancy mode,


supporting maintenance without opening the chassis
Operating 5°C–40°C (41°F–104°F)
temperature
Dimensions (H x 175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10
W x D) in.)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page26

RH5885H V3 Technical Specifications

Front view Form factor 4U 4-socket rack server


Number of 2 or 4
processors
ProcessorQ(8 Intel® Xeon® E7-4800/8800 v2/v3 series processors
Core options: 6, 8, 10, 12, 15,18
Memory Q(3 96 DDR3/DDR4 DIMMs Q(12
Maximum memory capacity: 3 TB
Internal 8 or 23 x 2.5-inch SAS/SATA HDDs or SSDs
storage
RAID 0, 1, 10, 5, 50, 6, and 60
RAID support 1 GB RAID cache
Optional iBBU or supercapacitor for power-on protection
PCIe 16 PCIe slots
expansion Four of them support hot swap and maintenance without
opening the chassis.
LOM network 2 or 4 x GE ports, or 2 x 10GE ports
Rear view port
PSUs in 1+1 or 2+2 redundancy mode:
PSU •220 V or 110 V AC PSUs
•–48 V DC PSUs
Fan module 5 hot-swappable fan modules in N+1 redundancy mode,
supporting maintenance without opening the chassis
Operating 5°C–40°C (41°F–104°F)
temperature
Dimensions 175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.)
(H x W x D)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page27

啊啊 14
Slide 27

Q(7 V3的CPU支持18核
Qibinbin (Robin), 6/8/2016

Q(11 最大内存1.5TB
Qibinbin (Robin), 6/8/2016

Slide 28

Q(3 新增DDR4
Qibinbin (Robin), 6/8/2016

Q(8 V3支持18核
Qibinbin (Robin), 6/8/2016

Q(12 最大内存3TB
Qibinbin (Robin), 6/8/2016
Huawei RH V3 Series Rack Servers
Introduction

RH5885H V3 Logical Architecture

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page28

RH5885(H) V3 Front View

1 Fan module 1 2 Fan module 2 13 DVD-ROM drive


3 Fan module 3 4 Fan module 4 14 LCD
5 Fan module 5 6 Network port link indicator 15 VGA port
7 Healthy indicator 8 UID button/indicator 16 USB port 2
9 Power button/indicator 10 Hard disk fault indicator 17 USB port 1
11 Hard disk active indicator 12 Hard disk

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page29

啊啊 15
Huawei RH V3 Series Rack Servers
Introduction

RH5885 V3 Rear View

1 Standard PCIe card 6 UID indicator 11 PSU 3


2 Serial port 7 LOM network port 12 Indicator for PSU 2
3 VGA port 8 Indicator for PSU 4 13 PSU 2
4 USB port 9 PSU 4 14 Indicator for PSU 1
5 Management network port 10 Indicator for PSU 3 15 PSU 1

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page30

RH5885H V3 Rear View

1 Hot swap indicator 2 Power indicator 3 Hot swap button


(on a hot-swappable PCIe card) (on a hot-swappable PCIe card) (on a hot-swappable PCIe card)
4 Standard PCIe riser card 1 5 NIC 6 UID indicator
7 Serial port 8 VGA port 9 BMC management network port 10 USB port
11 Standard PCIe riser card 2 12 PSU 2 13 PSU indicator
14 PSU 1 15 Hot-swappable PCIe riser card

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page31

啊啊 16
Huawei RH V3 Series Rack Servers
Introduction

RH5885H V3 PCIe Slots

 A hot-swappable PCIe riser card provides PCIe slots 13 to 16. The following table
describes the mapping between PCIe slots, processors, and compliant PCIe standards.

PCIe Slot Processor PCIe Standard


13
Processor 4
14 When no processor is installed in socket CPU4, PCIe slots
PCIe 3.0 x8
15 13 to 16 are unavailable.

16

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page32

RH5885H V3 Top View


RAID controller
Memory card iBBU or
riser supercapacitor

PCIe slots

Hot-
swappable
PCIe slot

4 processors

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page33

啊啊 17
Huawei RH V3 Series Rack Servers
Introduction

RH5885H V3 Memory Riser

 As shown in the figure, each processor corresponds to two


memory risers:

 Processor 1 corresponds to memory risers 1 and 2.

 Processor 2 corresponds to memory risers 3 and 4.

 Processor 3 corresponds to memory risers 5 and 6.

 Processor 4 corresponds to memory risers 7 and 8.

CPU1 CPU2 CPU3 CPU4

Memory Riser1

Memory Riser2

Memory Riser3

Memory Riser4

Memory Riser5

Memory Riser6

Memory Riser7

Memory Riser8
Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page34

RH5885H V3 DIMM Configuration Rules

Processor Socket DIMM Installation Sequence


If only one IDMM is to be configured, install it in slot A1.
If multiple DIMMs are to be configured, install them in the following
CPU1, CPU2, CPU3, and CPU4
sequence:
A1, B1, C1, D1, A2, B2, C2, D2, A3, B3, C3, and D3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page35

啊啊 18
Huawei RH V3 Series Rack Servers
Introduction

DIMM Configuration Rules

 A BC61MRTA memory riser with high specifications supports 1 to 12 DIMMs.


The following table lists the specific DIMM configuration rules. A black dot
indicates that a DIMM is installed in the specific slot.
Number of DIMMs
Memory Position
Channel 1 2 3 4 5 6 7 8 9 10 11 12

B1 ● ● ● ● ● ● ● ● ● ● ●

B B2 ● ● ● ● ● ● ●

B3 ● ● ●

BC A1 ● ● ● ● ● ● ● ● ● ● ● ●
61 A A2 ● ● ● ● ● ● ● ●
MR
TA A3 ● ● ● ●

C3 ● ●

C C2 ● ● ● ● ● ●

C1 ● ● ● ● ● ● ● ● ● ●

D3 ●

D D2 ● ● ● ● ●

D1 ● ● ● ● ● ● ● ● ●

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page36

DIMM Configuration Rules


 A BC61MRTB memory riser with low specifications supports 1 to 8 DIMMs. The
following table lists the specific DIMM configuration rules. A black dot indicates
that a DIMM is installed in the specific slot.
Memory Number of DIMMs
Position
Channel 1 2 3 4 5 6 7 8
B1 ● ● ● ● ● ● ●
B
B2 ● ● ●

A1 ● ● ● ● ● ● ● ●
A
BC61 A2 ● ● ● ●

MRTB C2 ● ●
C
C1 ● ● ● ● ● ●

D2 ●
D
D1 ● ● ● ● ●

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page37

啊啊 19
Huawei RH V3 Series Rack Servers
Introduction

RH5885 V3 Mainboard Layout

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page38

RH5885H V3 Mainboard Layout

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page39

啊啊 20
Huawei RH V3 Series Rack Servers
Introduction

Processor Installation Rules

 The RH5885H V3 supports one, two, or four processors.


 If only one processor is to be configured, install it in socket CPU1.
 If two processors are to be configured, install them in sockets CPU1 and CPU2.
 If four processors are to be configured, install them in sockets from CPU1 to CPU4.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page40

RH5885(H) V3 LCD

 The LCD on the front panel provides the following functions:


 Monitors the installation status and running status of
server components.
 Queries alarms and fault information to locate faults.
 Sets an IP address for the server.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page41

啊啊 21
Huawei RH V3 Series Rack Servers
Introduction

BMC Card
 The BMC card is installed on the mainboard and provides the following functions:
 Manages and monitors the server.
 Supports the KVM function.
 Supports the SOL redirection function.
 Supports the online upgrades of the BIOS, FPGA, and CPLD.
 Provides one VGA port, two USB ports, one 10/100Base-T management
network port, and one serial port (system serial port by default).

SN barcode

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page42

LOM

MAC SN
address barcode

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page43

啊啊 22
Huawei RH V3 Series Rack Servers
Introduction

Hot-Swappable Riser Card


2
1
1
2

1 2

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page44

Contents

 RH Series Server Overview and Positioning


 RH Series Server Description
 RHx2xx(H) V3
 5288 V3
 RH5885 V3
 RH8100 V3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page45

啊啊 23
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 Technical Specifications

Front view Form factor 8U 8-socket rack server


Number of 4 or 8
processors
Processor Intel Xeon E7-8800 v2/v3 series processors

Memory 192 DDR3/DDR4 DIMMs


Maximum memory capacity: 12 TB
Internal storage 12 or 24 x 2.5-inch SAS/SATA HDDs or SSDs
RAID 0, 1, 10, 5, 50, 6, and 60
RAID support 2 GB RAID cache
Optional iBBU or supercapacitor for power-on protection
PCIe expansion Up to 16 PCIe slots
LOM network 8 x GE ports, 4 x 10GE ports, or 4 x GE + 2 x 10GE ports
Rear view port
PSUs in 1+1 or 2+2 redundancy mode:
PSU 220 V or 110 V AC PSUs
–48 V DC PSUs

Fan module 8 hot-swappable fan modules in N+1 redundancy mode,


supporting maintenance without opening the chassis

Operating 5°C–40°C (41°F–104°F)


temperature

Dimensions (H x 352 mm x 447 mm x 855 mm (13.86 in. x 17.60 in. x 33.66


W x D) in.)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page46

RH8100 V3 Appearance

 The RH8100 V3 supports two models of front I/O modules:


 Front I/O module of model A (FM-A) delivers balanced performance. FM-A provides hard disks, RAID
controller cards, and up to six standard PCIe slots (provided by a PCIe riser card). The six PCIe slots can
accommodate PCIe SSDs and GPUs, but cannot accommodate cards that require connections to
external cables, such as NICs, HBAs, and IB cards.
 Front I/O module of model B (FM-B) delivers enhanced storage. FM-B provides only hard disks and
RAID controller cards, without any standard PCIe slot.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page47

啊啊 24
Huawei RH V3 Series Rack Servers
Introduction

Front View of the RH8100 V3 with FM-A

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page48

Front View of the RH8100 V3 with FM-B

 FM-B consists of two disk trays. Each tray provides 12 x 2.5-inch hard
disk slots. FM-B provides up to 24 hard disk slots.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page49

啊啊 25
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 Rear View

1.Location Lingt 15.PCIe Card status Light


2.FAN Light 16.PCIe Card status Light
3.HFC(High- 17.PCIe Card hot swap
performance Fusion button
Console)-2 18.network status Light
4.Power Light 19.network status Light
5.PCIe 10 20.network status Light
6.PCIe 9 21.HFC-1
7.PCIe 8 22.VGA
8.PCIe 7 23.RJ45
9.PCIe 6 24.iBMC
10.PCIe 5 25.USB
11.PCIe 4
12.PCIe 3
13.PCIe 2
14.PCIe 1

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page50

RH8100 V3 Components (Front View)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page51

啊啊 26
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 Components (Rear View)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page52

RH8100 V3 Components (Front View)


No. Name Description
1 Chassis A chassis houses and protects all components.

2 DVD-ROM drive and This module consists of a DVD-ROM drive for installing an OS and a touch LCD.
LCD

3 PCIe card This card is installed on a PCIe riser card. The front I/O module supports PCIe 3.0 x8 and PCIe 3.0 x16 cards, for
example, Huawei ES3000 PCIe SSDs and GPUs.
The iBBU provides power-off protection for the RAID controller card with the LSISAS2208 chip.
4 iBBU Note: You can use either an iBBU or a supercapacitor to provide power-off protection for the configured RAID
controller card.

5 Supercapacitor The supercapacitor provides power-off protection for the RAID controller card with the LSISAS2208 or LSISAS3108
chip.
6 PCIe riser card FM-A provides two PCIe riser cards. Each riser card provides two standard PCIe 3.0 x8 slots and one standard PCIe
3.0 x16 slot.
7 RAID controller card One or two RAID controller cards of the same model
This module provides hard disks, RAID controller cards, standard PCIe riser cards, PCIe cards, iBBUs, and
8 FM-A supercapacitors.
The PCIe slots on FM-A can accommodate PCIe SSDs and GPUs, but do not accommodate cards that require
connections to external cables, such as NICs, FC HBAs, and IB cards.
9 Hard disk Hot-swappable 2.5-inch hard disks
10 Memory board A CPU module supports a maximum of two memory boards. Each memory board provides 12 or 8 DIMM slots.
The server provides a maximum of 192 DDR3 DIMMs.

11 CPU module A CPU module is used to install a memory board and processor. The CPU modules are numbered 1 to 8 from left
to right. In dual-system mode, CPU modules 1 to 4 belong to system A and CPU modules 5 to 8 belong to system B.

12 Heat sink A heat sink adopts fool-proofing design and cools a processor. The processor on each compute node is configured
with one heat sink.
13 Processor Each CPU module provides only one Intel® Xeon® E7-8800 v2 series processor.
Each DDR3 DIMM provides a maximum of 64 GB memory capacity. The server provides a maximum of 12 TB
14 DIMM memory capacity, and supports 1066, 1333, or 1600 MHz DIMMs. (Note: It is estimated that 64 GB DIMMs will be
sold in Q1 2015.)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page53

啊啊 27
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 Components (Rear View)

No. Name Description

The fan modules are hot-swappable, and dissipate heat for the server. If one fan module is faulty,
1 Fan module
the adjacent fan modules run at full speed to ensure optimal heat dissipation for the server.

The RH8100 V3 provides four DC or AC PSUs in 2+2 redundancy mode:


2 PSU • AC PSUs: convert AC power into DC power for the RH8100 V3.
• DC PSUs: convert DC power into 12 V DC power for the RH8100 V3.

An HFC provides an Intel PCH, out-of-band management system, USB port, management network
3 HFC
port, serial port, and VGA port, and consists of the TPM, LOM, and USB flash drive.

The RH8100 V3 supports one GE NIC to provide two or four GE ports or one 10GE NIC to provide two
4 LOM
10GE ports. Both types of NICs support NC-SI.

A TPM is a security solution that complies with the Trusted Computing Group (TCG) standards. It
5 TPM (optional)
prevents viruses or unauthorized operations, enhancing the platform security.

6 USB flash drive A USB flash driver provides a maximum of 8 GB storage capacity.
Hot-swappable PCIe The rear I/O module supports two hot-swappable PCIe 3.0 x8 cards and two hot-swappable PCIe 3.0
7
card x16 cards.

Non-hot-swappable
8 The rear I/O module supports six non-hot-swappable PCIe 3.0 x8 cards.
PCIe card

9 Rear I/O module The rear I/O module supports four hot-swappable PCIe cards and six non-hot-swappable PCIe cards.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page54

CPU Module

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page55

啊啊 28
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 Front I/O Module

 The RH8100 V3 supports two models of front I/O modules. You can
choose one based on site requirements.
 FM-A with balanced performance
 One or two RAID controller cards
 12 HDDs
 Up to two PCIe riser cards
Each card supports three standard PCIe 3.0 slots.
 FM-B with enhanced storage
 One or two RAID controller cards
 Up to 24 hard disks

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page56

FM-A

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page57

啊啊 29
Huawei RH V3 Series Rack Servers
Introduction

FM-B

FM-B components

FM-B HDD drawer

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page58

RH8100 V3 Logical Architecture

 The RH8100 V3 logically consists of the following modules:


 System chassis module
 CPU modules
 Front I/O module
 Rear I/O module
 HFCs
 PSUs
 Fan modules

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page59

啊啊 30
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 QPI Topology

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page60

Memory Subsystem Topology

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page61

啊啊 31
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 PCIe Topology (FM-A)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page62

RH8100 V3 PCIe Topology (FM-B)

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page63

啊啊 32
Huawei RH V3 Series Rack Servers
Introduction

Topologies of Other Ports on the RH8100 V3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page64

FusionPar Technology

 The key to FusionPar is to change the interconnection topology between


processors through interworking between the iBMC and BIOS.
 The RH8100 V3 can operate in single-system or dual-system mode.
 In single-system mode, the eight processors on the RH8100 V3 are in the same QPI
topology.
 In dual-system mode, the eight processors are divided into two groups. The four
processors in each group are in one QPI topology.
 In short, the processors connected over the QPI link are in one partition.
 The RH8100 V3 employs the Huawei FusionPar technology to implement the
hard partitioning function.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page65

啊啊 33
Huawei RH V3 Series Rack Servers
Introduction

FusionPar Technology

Symmetrical distribution of service resources

Total Partition A Partition B

8 CPUs CPU CPU CPU CPU CPU CPU CPU CPU

192 DIMMs 96 DIMMs 96 DIMMs

6 hard disks 6 hard disks


12 hard disks

8 PCIe slots 8 PCIe slots


16 PCIe slots

HFC-1 HFC-2

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page66

Hard Partitioning — Huawei FusionPar

GE
Communication
between
partitions
HFC-1 HFC-2 HFC-1 HFC-2

CPU CPU CPU CPU CPU CPU CPU CPU

CPU CPU CPU CPU CPU CPU CPU CPU

Single-system mode Dual-system mode

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page67

啊啊 34
Huawei RH V3 Series Rack Servers
Introduction

QPI Topology in Single-System Mode

Single-system mode

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page68

QPI Topology in Dual-System Mode

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page69

啊啊 35
Huawei RH V3 Series Rack Servers
Introduction

Memory Board Hot Swap

Memory board (x16) CPU module (x8)

Each CPU module provides two memory boards.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page70

Memory Board Hot Swap

HFC HFC

Step 1_b: An alarm is reported to Step 1_c: The administrator triggers a


the administrator. hot swap operation.

IVB-EX IVB-EX IVB-EX

Step 3: Data is migrated


from the faulty memory
MEM-15
MEM-1

MEM-3

board to the spare one.


New -3

Steps 4 and 5: The faulty


memory board is replaced
with a new one.

Step 1_a: A fault is Step 2:


MEM-16
MEM-2

MEM-4

detected with the PFA The spare memory board


mechanism. goes online.

Running Error Sparing

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page71

啊啊 36
Huawei RH V3 Series Rack Servers
Introduction

RH8100 V3 DIMM Configuration Rules

Memory channel compositions

Memory
Composition
Channel
DIMM 01
Channel 0 DIMM 02
DIMM 03
DIMM 11
Channel 1 DIMM 12
DIMM 13  DIMM installation sequence (DDR3-12DIMM-
DIMM 21 memory board)
Channel 2 DIMM 22
 The figure above shows the installation positions
DIMM 23
of 12 DDR3 DIMMs on a memory board. On a
DIMM 31
Channel 3 DIMM 32 memory riser that supports eight DDR3 DIMMs,
DIMM 33 DIMM slots 03, 13, 23, and 33 are vacant.

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page72

Summary

 RH series server overview and positioning


 RH series server description, including the structures, and
components

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page73

啊啊 37
Huawei RH V3 Series Rack Servers
Introduction

Questions

1. What are Huawei RH series servers? How do you distinguish


these servers?
2. Please describe the RH5885 V3 server hardware structure.
3. What RAID controller cards and RAID levels do Huawei RH series
servers support?

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page74

Exercises

 True or false questions


1. The RH2285 V3 and RH2288 V3 are 2U 2-socket servers. (T or F)
2. Two 2.5-inch hard disks used as system partitions are installed at the rear of the
RH2285 V3. This improves data security and reliability, and expands data storage
capacity. (T or F)
 Multiple-choice questions
1. Which of the following RH series servers support hot swap of PCIe cards? ( )
A. RH2488 V2
B. 5885 V3
C. RH5885H V3
D. RH8100 V3

Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved. Page75

啊啊 38
Huawei RH V3 Series Rack Servers
Introduction

Thank you