Vous êtes sur la page 1sur 4

Company: Project: Engineering Contractor:

OFFSITES ENGINEERING WORKS


FOR THE ERBIL REFINERY
40,000 B/D EXPANSION PROJECT

Contract no.: 10J01762-01


Company doc. no.: Job no.: 10J01762 Engineering doc. no.:
N/A Sheet 1 of 4 10J01762-ICT-DS-000-017

OFFSITES ENGINEERING WORKS FOR THE


ERBIL REFINERY 40,000 B/D EXPANSION PROJECT

DATA SHEET FOR CORIOLIS FLOWMETERS

D0 31/08/2011 Approved for Design Lucarelli Pagliardini Cilia


C0 29/07/2011 Issued for Company approval Lucarelli Pagliardini Cilia
REV. DATE REVISION TITLE PREPARED CHECKED APPROVED

File name: 10J01762-ICT-DS-000-017-D0.doc Printed on 31/08/2011


OFFSITES ENGINEERING WORKS FOR THE ERBIL REFINERY 40,000 B/D EXPANSION PROJECT
DATA SHEET FOR CORIOLIS FLOWMETERS
Company doc. no.: Rev.: C0 D0 Engineering doc. no.:
N/A Sheet 2 of 4 10J01762-ICT-DS-000-017

CORIOLIS FLOWMETER
01 TAG NO. 3#-FIT-050A 48 TYPE Not required
GENERAL

02 P&ID 10J01762-PRO-DW-000-004 49 ENCLOSURE TYPE -

TOTALIZER INDICATOR
03 SERVICE Crude oil metering unit 50 SUPPLY VOLTAGE -
04 LINE/EQUIPMENT NO. 6”-BA1-CO-503-P 51 CONTACTS ARRANGEMENT -
05 MANUFACTURER * 52 RESET STYLE -
06 LINE/EQUIP. DESIGN PRESSURE 25 bar g 53 INTEGRAL INDICATOR STYLE -
PIPING DATA

07 LINE/EQUIP. DESIGN TEMP. 0 ÷ 60 °C 54 ENCLOSURE PROTECTION -


08 PIPE NOMINAL SIZE 6” 55 EX. CLASSIFICATION -
09 PIPE WALL THICKNESS (mm) 7.11 mm 56 MOUNTING LOCATION/TYPE -
10 FLANGE MATERIAL ASTM A 105 57 MATERIAL, ENCLOSURE -
11 CORROSION ALLOW. 1.58 mm 58 TYPE Not required
12 FLUID/PHASE Crude oil / liquid 59 MATERIAL -
13 OPERATING PRESS./TEMP. 16 bar g / 10 ÷ 30 °C 60 CONNECTION -
PROCESS DATA

FLOW STRAIGHTENER
14 AMBIENT TEMP. 0÷50 °C 61 OTHER -
15 ACTUAL VOL. FLOW RANGE(m3/h) 0÷658.7 62
16 FLUID VELOCITY RANGE (m/s) 0÷10 (note 1) 63
17 VISCOSITY / DENSITY 3.77 cp / 840 kg/m3 64
18 SOLID PARTIC. CONTENT(by Vol.) - 65
19 66
20 TYPE Coriolis Meter 67
21 MOUNTING In-line 68
22 OPERATING TEMP. LIMITS * 69
23 OPERATING PRESS. LIMITS * 70 MANUFACTURER MODEL NO. *
INSTRUMENT CHARACTERISTICS

24 PRESS. LOSS AT FULL RANGE * 71 MOUNTING Direct on meter body


25 COMPLETE ASSEMBLY Integral transmitter 72 MAX DISTANCE METER/TRANSM. *
26 FACE TO FACE DIMENSION * 73 CABLE CONNECTION *
27 WEIGHT * 74 CABLE ENTRY (NO./TYPE) (*) / ISO M20x1.5 mm
28 CAL. FLOW RANGE(m3/h) * 75 NO. OF CABLE CONNECTED *
29 CAL. VELOCITY RANGE (m/s) * 76 DIMENSION *
30 ACCURACY ±0.3% * 77 MATERIAL *
31 LINEARITY ±0.15% * 78 ENCLOSURE PROTECTION IP 65 (min)
TRANSMITTER

32 REPEATABILITY ±0.2% * 79 EX. CLASSIFICATION Ex-d IIB T3 / ATEX 94/9/EC


33 RANGEABILITY 100 : 1 * 80 PROTECTIVE COATING *
34 FLOW RANGE LIMITS (m3/h) * 81 INDICATOR Local LCD display
35 VELOCITY RANGE LIMITS (m/s) * 82 OUTPUT SIGNAL 4-20 mA, 2-wires
36 83 COMUNICATION HART protocol
37 NOMINAL SIZE 6” * 84 SUPPLY VOLTAGE 24 VDC (loop powered)
38 MANUFACTURER MODEL NO. * 85 CONSUMPTION *
39 PROCESS CONN. SIZE/TYPE 6” / flanged RF * 86 LOAD LIMITATION *
40 PRESSURE RATING ANSI 300# 87
41 FACE TO FACE DIMENSION * 88
METER BODY

42 FLOW TUBE INNER DIAMETER * 89


43 NO. OF FLOW TUBES * 90
44 SOUR SERVICE SPEC. - 91 TAG/DATA PLATE MATERIAL Required / SS
ACCESSORIES/OPTION

45 MATERIAL, FLOW TUBE * 92 TROPICALIZATION Required


46 MATERIAL, FLANGE ASTM A 105 93 FREQUENCY OUTPUT SIGNAL -
47 MATERIAL, FLOW TUBE COVER * 94
48 PROTECTIVE COATING/COLOR Manufacturer STD * 95
49 96
50 97
NOTES
(*) Data to be provided or to be confirmed by Supplier.
(1) Data for 6” pipe.
(2) Supplier is required to provide, as a minimum, the following documents: IDS Std for Client ‘s approval, calculation sheets, dwg, technical bulletins, O&M manuals,
manufacturing data book, quality book (with all test reports, material certificates, mechanical/electrical protection certificates...) as request on purchaser requisition
documents.

File name: 10J01762-ICT-DS-000-017-D0.doc Printed on 31/08/2011


OFFSITES ENGINEERING WORKS FOR THE ERBIL REFINERY 40,000 B/D EXPANSION PROJECT
DATA SHEET FOR CORIOLIS FLOWMETERS
Company doc. no.: Rev.: C0 D0 Engineering doc. no.:
N/A Sheet 3 of 4 10J01762-ICT-DS-000-017

CORIOLIS FLOWMETER
01 TAG NO. 3#-FIT-050B 48 TYPE Not required
GENERAL

02 P&ID 10J01762-PRO-DW-000-004 49 ENCLOSURE TYPE -

TOTALIZER INDICATOR
03 SERVICE Crude oil metering unit 50 SUPPLY VOLTAGE -
04 LINE/EQUIPMENT NO. 6”-BA1-CO-504-P 51 CONTACTS ARRANGEMENT -
05 MANUFACTURER * 52 RESET STYLE -
06 LINE/EQUIP. DESIGN PRESSURE 25 bar g 53 INTEGRAL INDICATOR STYLE -
PIPING DATA

07 LINE/EQUIP. DESIGN TEMP. 0 ÷ 60 °C 54 ENCLOSURE PROTECTION -


08 PIPE NOMINAL SIZE 6” 55 EX. CLASSIFICATION -
09 PIPE WALL THICKNESS (mm) 7.11 mm 56 MOUNTING LOCATION/TYPE -
10 FLANGE MATERIAL ASTM A 105 57 MATERIAL, ENCLOSURE -
11 CORROSION ALLOW. 1.58 mm 58 TYPE Not required
12 FLUID/PHASE Crude oil / liquid 59 MATERIAL -
13 OPERATING PRESS./TEMP. 16 bar g / 10 ÷ 30 °C 60 CONNECTION -
PROCESS DATA

FLOW STRAIGHTENER
14 AMBIENT TEMP. 0÷50 °C 61 OTHER -
15 ACTUAL VOL. FLOW RANGE(m3/h) 0÷658.7 62
16 FLUID VELOCITY RANGE (m/s) 0÷10 (note 1) 63
17 VISCOSITY / DENSITY 3.77 cp / 840 kg/m3 64
18 SOLID PARTIC. CONTENT(by Vol.) - 65
19 66
20 TYPE Coriolis Meter 67
21 MOUNTING In-line 68
22 OPERATING TEMP. LIMITS * 69
23 OPERATING PRESS. LIMITS * 70 MANUFACTURER MODEL NO. *
INSTRUMENT CHARACTERISTICS

24 PRESS. LOSS AT FULL RANGE * 71 MOUNTING Direct on meter body


25 COMPLETE ASSEMBLY Integral transmitter 72 MAX DISTANCE METER/TRANSM. *
26 FACE TO FACE DIMENSION * 73 CABLE CONNECTION *
27 WEIGHT * 74 CABLE ENTRY (NO./TYPE) (*) / ISO M20x1.5 mm
28 CAL. FLOW RANGE(m3/h) * 75 NO. OF CABLE CONNECTED *
29 CAL. VELOCITY RANGE (m/s) * 76 DIMENSION *
30 ACCURACY ±0.3% * 77 MATERIAL *
31 LINEARITY ±0.15% * 78 ENCLOSURE PROTECTION IP 65 (min)
TRANSMITTER

32 REPEATABILITY ±0.2% * 79 EX. CLASSIFICATION Ex-d IIB T3 / ATEX 94/9/EC


33 RANGEABILITY 100 : 1 * 80 PROTECTIVE COATING *
34 FLOW RANGE LIMITS (m3/h) * 81 INDICATOR Local LCD display
35 VELOCITY RANGE LIMITS (m/s) * 82 OUTPUT SIGNAL 4-20 mA, 2-wires
36 83 COMUNICATION HART protocol
37 NOMINAL SIZE 6” * 84 SUPPLY VOLTAGE 24 VDC (loop powered)
38 MANUFACTURER MODEL NO. * 85 CONSUMPTION *
39 PROCESS CONN. SIZE/TYPE 6” / flanged RF * 86 LOAD LIMITATION *
40 PRESSURE RATING ANSI 300# 87
41 FACE TO FACE DIMENSION * 88
METER BODY

42 FLOW TUBE INNER DIAMETER * 89


43 NO. OF FLOW TUBES * 90
44 SOUR SERVICE SPEC. - 91 TAG/DATA PLATE MATERIAL Required / SS
ACCESSORIES/OPTION

45 MATERIAL, FLOW TUBE * 92 TROPICALIZATION Required


46 MATERIAL, FLANGE ASTM A 105 93 FREQUENCY OUTPUT SIGNAL -
47 MATERIAL, FLOW TUBE COVER * 94
48 PROTECTIVE COATING/COLOR Manufacturer STD * 95
49 96
50 97
NOTES
(*) Data to be provided or to be confirmed by Supplier.
(1) Data for 6” pipe.
(2) Supplier is required to provide, as a minimum, the following documents: IDS Std for Client ‘s approval, calculation sheets, dwg, technical bulletins, O&M manuals,
manufacturing data book, quality book (with all test reports, material certificates, mechanical/electrical protection certificates...) as request on purchaser requisition
documents.

File name: 10J01762-ICT-DS-000-017-D0.doc Printed on 31/08/2011


OFFSITES ENGINEERING WORKS FOR THE ERBIL REFINERY 40,000 B/D EXPANSION PROJECT
DATA SHEET FOR CORIOLIS FLOWMETERS
Company doc. no.: Rev.: C0 D0 Engineering doc. no.:
N/A Sheet 4 of 4 10J01762-ICT-DS-000-017

CORIOLIS FLOWMETER
01 TAG NO. 3#-FIT-050C 48 TYPE Not required
GENERAL

02 P&ID 10J01762-PRO-DW-000-004 49 ENCLOSURE TYPE -

TOTALIZER INDICATOR
03 SERVICE Crude oil metering unit 50 SUPPLY VOLTAGE -
04 LINE/EQUIPMENT NO. 6”-BA1-CO-505-P 51 CONTACTS ARRANGEMENT -
05 MANUFACTURER * 52 RESET STYLE -
06 LINE/EQUIP. DESIGN PRESSURE 25 bar g 53 INTEGRAL INDICATOR STYLE -
PIPING DATA

07 LINE/EQUIP. DESIGN TEMP. 0 ÷ 60 °C 54 ENCLOSURE PROTECTION -


08 PIPE NOMINAL SIZE 6” 55 EX. CLASSIFICATION -
09 PIPE WALL THICKNESS (mm) 7.11 mm 56 MOUNTING LOCATION/TYPE -
10 FLANGE MATERIAL ASTM A 105 57 MATERIAL, ENCLOSURE -
11 CORROSION ALLOW. 1.58 mm 58 TYPE Not required
12 FLUID/PHASE Crude oil / liquid 59 MATERIAL -
13 OPERATING PRESS./TEMP. 16 bar g / 10 ÷ 30 °C 60 CONNECTION -
PROCESS DATA

FLOW STRAIGHTENER
14 AMBIENT TEMP. 0÷50 °C 61 OTHER -
15 ACTUAL VOL. FLOW RANGE(m3/h) 0÷658.7 62
16 FLUID VELOCITY RANGE (m/s) 0÷10 (note 1) 63
17 VISCOSITY / DENSITY 3.77 cp / 840 kg/m3 64
18 SOLID PARTIC. CONTENT(by Vol.) - 65
19 66
20 TYPE Coriolis Meter 67
21 MOUNTING In-line 68
22 OPERATING TEMP. LIMITS * 69
23 OPERATING PRESS. LIMITS * 70 MANUFACTURER MODEL NO. *
INSTRUMENT CHARACTERISTICS

24 PRESS. LOSS AT FULL RANGE * 71 MOUNTING Direct on meter body


25 COMPLETE ASSEMBLY Integral transmitter 72 MAX DISTANCE METER/TRANSM. *
26 FACE TO FACE DIMENSION * 73 CABLE CONNECTION *
27 WEIGHT * 74 CABLE ENTRY (NO./TYPE) (*) / ISO M20x1.5 mm
28 CAL. FLOW RANGE(m3/h) * 75 NO. OF CABLE CONNECTED *
29 CAL. VELOCITY RANGE (m/s) * 76 DIMENSION *
30 ACCURACY ±0.3% * 77 MATERIAL *
31 LINEARITY ±0.15% * 78 ENCLOSURE PROTECTION IP 65 (min)
TRANSMITTER

32 REPEATABILITY ±0.2% * 79 EX. CLASSIFICATION Ex-d IIB T3 / ATEX 94/9/EC


33 RANGEABILITY 100 : 1 * 80 PROTECTIVE COATING *
34 FLOW RANGE LIMITS (m3/h) * 81 INDICATOR Local LCD display
35 VELOCITY RANGE LIMITS (m/s) * 82 OUTPUT SIGNAL 4-20 mA, 2-wires
36 83 COMUNICATION HART protocol
37 NOMINAL SIZE 6” * 84 SUPPLY VOLTAGE 24 VDC (loop powered)
38 MANUFACTURER MODEL NO. * 85 CONSUMPTION *
39 PROCESS CONN. SIZE/TYPE 6” / flanged RF * 86 LOAD LIMITATION *
40 PRESSURE RATING ANSI 300# 87
41 FACE TO FACE DIMENSION * 88
METER BODY

42 FLOW TUBE INNER DIAMETER * 89


43 NO. OF FLOW TUBES * 90
44 SOUR SERVICE SPEC. - 91 TAG/DATA PLATE MATERIAL Required / SS
ACCESSORIES/OPTION

45 MATERIAL, FLOW TUBE * 92 TROPICALIZATION Required


46 MATERIAL, FLANGE ASTM A 105 93 FREQUENCY OUTPUT SIGNAL -
47 MATERIAL, FLOW TUBE COVER * 94
48 PROTECTIVE COATING/COLOR Manufacturer STD * 95
49 INTERNAL LINING None 96
50 97
NOTES
(*) Data to be provided or to be confirmed by Supplier.
(1) Data for 6” pipe.
(2) Supplier is required to provide, as a minimum, the following documents: IDS Std for Client ‘s approval, calculation sheets, dwg, technical bulletins, O&M manuals,
manufacturing data book, quality book (with all test reports, material certificates, mechanical/electrical protection certificates...) as request on purchaser requisition
documents.

File name: 10J01762-ICT-DS-000-017-D0.doc Printed on 31/08/2011