WARNING: The wiring technician must be trained and experienced CAUTION: It is good practice to power electronic or digital controllers
with electronic circuits. Disconnect power supply before attempting any from a separate power transformer than that used for actuators or other
wiring connections or changes. Make all connections in accordance end devices. The power supply design in our actuators and other end
with wiring diagrams and follow all applicable local and national codes. devices use half wave rectification. Some controllers use full wave
Provide disconnect and overload protection as required. Use copper, rectification. When these two different types of power supplies are
twisted pair, conductors only. If using electrical conduit, the attachment connected to the same power transformer and the DC commons are
to the actuator must be made with flexible conduit. connected together, a short circuit is created across one of the diodes in
the full wave power supply, damaging the controller. Only use a single
Always read the controller manufacturer’s installation power transformer to power the controller and actuator if you know the
literature carefully before making any connections. Follow all controller power supply uses half wave rectification.
instructions in this literature. If you have any questions, contact
the controller manufacturer and/or Belimo. Multiple actuators, one transformer
Multiple actuators may be powered from one transformer provided the
Transformer(s) following rules are followed:
Belimo actuators require a 24 VAC Class 2 transformer. The 1. The TOTAL current draw of the actuators (VA rating) is less than or
actuator enclosure cannot be opened in the field, there are no equal to the rating of the transformer.
parts or components to be replaced or repaired. 2. Polarity on the secondary of the transformer is strictly followed.
This means that all No. 1 wires from all actuators are connected
– EMC Directive: 2004/108/EC to the common leg on the transformer and all No. 2 wires from all
– Software Class A: Mode of Operation Type 1 actuators are connected to the hotleg. Mixing wire No. 1 & 2 on one
– Low Voltage Directive: 2006/95/EC leg of the transformer will result in erratic operation or failure of the
actuator and/or controls.
Example: 3 AF Actuators Supplied, 16 Ga. wire (refer to table on
page 3) Multiple actuators, multiple transformers
350 ft. (allowable wire length) ÷ 3 actuators = 117 ft. maximum wire run Multiple actuators positioned by the same control signal may be powered
from multiple transformers provided the following rules are followed:
Typical Transformer Sizing 1. The transformers are properly sized.
2. All No. 1 wires from all actuators are tied together and tied to the
Required VA negative leg of the control signal. See wiring diagram.
Actuator Series Voltage Per Actuator
AMQ… NMQ…
GK/
VA EF AF NF LF…US TF…US NKQ… GM/GR… AM/AR… NM… LM/LR… CM… AH… LH… LU… TR… LMQ… AHQ…
GKR…
LHQ…
wire
gauge 16 10 9 7 5 21 22 7 6 6 5 1.5 6 5 5 1 18
24 VAC
16 225 350 390 500 700 165 160 500 600 600 700 1200 600 700 700 1400 200
800-543-9038 USA
14 360 550 600 800 1100 275 260 800 925 925 300
12 550 900 1000 1125 1175 440 420 1125 1150 1150 500
VA
wire 21 8.5 11 6.5 7.5 6 7 7.5 6.5 4.5 3.5 3
gauge
MAX Distance between Actuator and Supply (feet)
20 175 150 175 250 350 400
18 110 265 215 375 325 375 325 300 325 450 600 750
110 VAC
16 165 415 345 575 500 575 500 450 500 700 1000 1125
866-805-7089 CANADA
14 275 650 545 900 800 900 800 700 800 1125 1150 1175
12 440 1050 895 1150 1125 1150 1125 1125 1125
EF AF..UP AF…US NF..UP LF…US TF…US GM… AM… NM… LM… CM… LU
VA
wire 29 18 11 9.5 7 6 7 7.5 6.5 4.5 3.5 3
gauge
MAX Distance between Actuator and Supply (feet)
20 175 150 175 250 325 400
18 80 120 215 220 325 375 325 300 325 450 600 750
220 VAC
16 125 200 345 350 500 575 500 450 500 700 1000 1125
14 200 300 545 550 800 900 800 700 800 1125 1500 1175
12 310 475 895 900 1125 1150 1125 1125 1125
3
4
SY1 SY2 SY3 SY4 SY5
Amps Amps Amps Amps Amps
wire gauge 1.8 3 3 6 6.5
MAX Distance between Actuator and Supply (feet)
18 92 55 55
16 144 87 87 43 40
24 VAC
14 233 140 140 70 65
800-543-9038 USA
12 357 214 214 107 99
10 606 364 364 182 168
8 905 543 543 271 250
SY1 SY2 SY3 SY4 SY5 SY6 SY7 SY8 SY9 SY10 SY11 SY12
Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps
wire gauge 0.5 1 1 1.3 1.5 1.8 3.2 4 3.2 4 3 4
MAX Distance between Actuator and Supply (feet)
18 1515 758 758 583 505 421 237 189 237 189 253 189
16 2381 1190 1190 916 794 661 372 298 372 298 397 298
110 VAC
14 3846 1923 1923 1479 1282 1068 601 481 601 481 641 481
Wire Size vs. Length of Run for SY Series Actuators
12 5882 2941 2941 2262 1961 1634 919 735 919 735 980 735
866-805-7089 CANADA
10 10000 5000 5000 3846 3333 2778 1563 1250 1563 1250 1667 1250
8 14925 7463 7463 5741 4975 4146 2332 1866 2332 1866 2488 1866
SY1 SY2 SY3 SY4 SY5 SY6 SY7 SY8 SY9 SY10 SY11 SY12
Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps
wire gauge 0.3 0.5 0.5 0.6 0.7 0.8 1.6 2 1.6 2 1.6 2.2
MAX Distance between Actuator and Supply (feet)
18 5051 3030 3030 2525 2165 1894 947 758 947 758 947 689
16 7937 4762 4762 3968 3401 2976 1488 1190 1488 1190 1488 1082
220 VAC
14 12821 7692 7692 6410 5495 4808 2404 1923 2404 1923 2404 1748
12 19608 11765 11765 9804 8403 7353 3676 2941 3676 2941 3676 2674
10 33333 20000 20000 16667 14286 12500 6250 5000 6250 5000 6250 4545
8 49751 29851 29851 24876 21322 18657 9328 7463 9328 7463 9328 6784
The NEC mandates that 24 VAC over 100 VA power requires CLASS 1 wiring conduit. Local codes may vary. Do NOT mix CLASS 1 & CLASS 2 circuits in
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
1 Provide overload protection and disconnect as required.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, 3 Actuators may also be powered by 24 VDC.
may result in minor or moderate injury. It may also be used to Actuators with plenum rated cable do not have
alert against unsafe practices. 5
numbers on wires; use color codes instead.
2
Equipment damage!
Actuators may be connected in parallel. Power
A Actuators with appliance cables are numbered.
consumption and input impedance must be observed.
WARNING
Live Electrical Components!
During installation, testing, servicing and troubleshooting of this APPLICATION NOTES
product, it may be necessary to work with live electrical
components. Have a qualified licensed electrician or other Meets cULus requirements without the need of an
individual who has been properly trained in handling live electrical electrical ground connection.
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components
could result in death or serious injury. On/Off
On/Off
24 VAC Transformer 1 3 5
1 0
The indication of direction
is valid for switch position 1.
NKQ
On/Off
24 VAC Transformer 1 3 5
GK
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
CAUTION 14
TF120(-S) US can be supplied with both 120 VAC
Indicates a potentially hazardous situation which, if not avoided, and 230 VAC.
may result in minor or moderate injury. It may also be used to
alert against unsafe practices. 19 UP models and TF120(-S) US uses “L” instead of “H”
on #2 wire.
Equipment damage!
2 Actuators may be connected in parallel. Power 20 All 120 VAC, 230 VAC and UP actuators use appliance rated
consumption and input impedance must be observed. cables.
UP Universal Power Supply (UP) models can be supplied
WARNING with 24 VAC up to 240 VAC.
Live Electrical Components!
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical
components. Have a qualified licensed electrician or other APPLICATION NOTES
individual who has been properly trained in handling live electrical
components perform these tasks. Failure to follow all electrical Meets cULus requirements without the need of an
safety precautions when exposed to live electrical components electrical ground connection.
could result in death or serious injury.
On/Off
120 VAC 14 UP
2 20 19
230 VAC
W232_11
Hazard Identification
INSTALLATION NOTES
Warnings and Cautions appear at appropriate sections throughout
this manual. Read these carefully.
3 Actuators may also be powered by 24 VDC.
CAUTION Actuators with plenum rated cable do not have numbers on
Indicates a potentially hazardous situation which, if not avoided, 5 wires; use color codes instead. Actuators with appliance
may result in minor or moderate injury. It may also be used to cables are numbered.
alert against unsafe practices. Actuators Hot wire must be connected to the control board
6 common.
Equipment damage!
2 Actuators may be connected in parallel. Power For triac sink the Common connection from the actuator
consumption and input impedance must be observed. 11 must be connected to the Hot connection of the controller.
The actuator must be connected to the control board common.
WARNING
Live Electrical Components!
During installation, testing, servicing and troubleshooting of this APPLICATION NOTES
product, it may be necessary to work with live electrical Meets cULus requirements without the need of an
components. Have a qualified licensed electrician or other electrical ground connection.
individual who has been properly trained in handling live electrical
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components † Actuator Wire Number Color
could result in death or serious injury.
TF24-3 US 4 Org
TF24-3-S US 5 Org
LF24-3 US 4 Grn
Floating Point LF24-3-S US 5 Wht
Triac Source
24 VAC Transformer 3 5
a Wht (3) +
2 5
Hot Com
b † + Blk (1) Common
Red (2) + Hot
CW CCW
LF24-3(-S) US Wht (3) +
The indication of direction LFC24-3-R US † +
is valid for switch position CW. LFC24-3-S US
CW CCW
TF24-3(-S) US LF24-3(-S) US
TF24-3(-S) US
24 VAC Transformer
Triac Sink with Separate Transformer
Line
Volts
2 5 11
24 VAC Transformer
Hot Com
Blk (1) Common 24 VAC Transformer
Line
Red (2) + Hot 6 Volts
Line
Wht (3) + Volts 2 5
† +
Blk (1) Common
CW CCW
LF24-3(-S) US Hot Com
TF24-3(-S) US
Red (2) + Hot 6
Controller Wht (3) +
The indication of direction
† +
is valid for switch position CW.
CW CCW
LF24-3(-S) US
TF24-3(-S) US
Actuators: LMB24-3(-S) (-P5) (-P10) (-T) AMB24-3(-S) LMX24-3(-T) AMX24-3(-T) LRB24-3(-S) ARX24-3
TR24-3(-T) US NMB24-3 GMB24-3… NMX24-3(-T) GMX24-3… ARB24-3(-S) LRX24-3
CMB24-3… ARB24-3-5 GRB24-3-5 GRB24-3-7 GMB24-3-X1 LRCB24-3(-S)
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
3 Actuators may also be powered by 24 VDC.
CAUTION
5 Actuators with plenum rated cable do not have
Indicates a potentially hazardous situation which, if not avoided, numbers on wires; use color codes instead.
may result in minor or moderate injury. It may also be used to Actuators with appliance cables are numbered.
alert against unsafe practices.
16
The TR24-3-T US actuators are provided with
Equipment damage! a numbered screw terminal strip instead of cable.
2 Actuators may be connected in parallel. Power
consumption and input impedance must be observed. 17 TR24-3 US actuators cannot be wired in parallel.
WARNING
Live Electrical Components!
During installation, testing, servicing and troubleshooting of this APPLICATION NOTES
product, it may be necessary to work with live electrical
components. Have a qualified licensed electrician or other Meets cULus requirements without the need of an
individual who has been properly trained in handling live electrical electrical ground connection.
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components
could result in death or serious injury.
Wht 3 + Wht 3 +
Note: TR24-3 (-T) US cannot Note: TR24-3 (-T) US cannot
be wired in parallel with be wired in parallel with
TR24-3 (-T) US TR24-3 (-T) US
any actuator. any actuator.
Refer to page 26 for auxiliary switch (-S models) and -P5, -P10 potentiometer wiring.
Actuators: GKB24-3
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
1 Provide overload protection and disconnect as required.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, 3 Actuators may also be powered by 24 VDC.
may result in minor or moderate injury. It may also be used to Control signal may be pulsed from either the Hot (source)
alert against unsafe practices. 5 or the Common (sink) 24 VAC line.
Equipment damage! Contact closures A & B also can be triacs.
2 Actuators may be connected in parallel. Power 8 A & B should both be closed for triac source and open for
consumption and input impedance must be observed. triac sink.
WARNING 9 For triac sink the common connection from the actuator
Live Electrical Components! must be connected to the hot connection of the controller.
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical
components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical
components perform these tasks. Failure to follow all electrical APPLICATION NOTES
safety precautions when exposed to live electrical components Meets cULus requirements without the need of an
could result in death or serious injury. electrical ground connection.
Floating Point
N40067 - 7/11 - Subject to change. © Belimo Aircontrols (USA), Inc.
GKB24-3
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
15 LMB(X), NMB(X), AMB(X), GMB(X), LRB(X), and ARB(X)
CAUTION can be supplied with either 120 VAC or 230 VAC.
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury. It may also be used to 19 All 120VAC and 230VAC actuators use appliance rated
alert against unsafe practices. cables.
Equipment damage!
2 Actuators may be connected in parallel. Power A Actuators with appliance cables are numbered.
consumption and input impedance must be observed.
WARNING
Live Electrical Components! APPLICATION NOTES
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical Meets cULus requirements without the need of an
components. Have a qualified licensed electrician or other electrical ground connection.
individual who has been properly trained in handling live electrical
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components
could result in death or serious injury.
2 19 2 19
100 to 240 VAC 15 100 to 240 VAC 15
a open a
Wht (3) + Wht (3) +
a closed
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
3 Actuators may also be powered by 24 VDC.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, 5 Actuators with plenum rated cable do not have
may result in minor or moderate injury. It may also be used to numbers on wires; use color codes instead.
alert against unsafe practices. Actuators with appliance cables are numbered.
Equipment damage! 6 Only connect common to neg. (–) leg of control circuits.
4 Up to four actuators may be connected in parallel if not
mechanically linked. Power consumption and input
impedance must be observed.
6 8
AFA24-SR US
TF24-SR(-S) US
Actuators: LMB24-SR (-T) NMB24-SR LMX24-SR (-T) NMX24-SR (-T) LRB24-SR TR24-SR (-T) US
AMB24-SR GMB24-SR AMX24-SR (-T) GMX24-SR ARB24-SR LRX24-SR ARX24-SR
CMB24-SR-L CMB24-SR-R GKB24-SR GKX24-SR NKQB24-SR NKQX24-SR
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
3 Actuators may also be powered by 24 VDC.
CAUTION
5 Actuators with plenum rated cable do not have
Indicates a potentially hazardous situation which, if not avoided, numbers on wires; use color codes instead.
may result in minor or moderate injury. It may also be used to Actuators with appliance cables are numbered.
alert against unsafe practices.
6 Only connect common to neg. (–) leg of control circuits.
Equipment damage! Terminal models (-T) have no-feedback.
4
Up to four actuators may be connected in parallel if not
mechanically linked. Power consumption and input
impedance must be observed.
APPLICATION NOTES
WARNING
Meets cULus requirements without the need of an
Live Electrical Components!
electrical ground connection.
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical
A 500 Ω resistor converts the 4 to 20 mA control
components. Have a qualified licensed electrician or other 7 signal to 2 to 10 VDC.
individual who has been properly trained in handling live electrical
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components
could result in death or serious injury.
24 VAC Transformer 3 4
24 VAC Transformer 3 4
TR24-SR (-T) US
6
1 0
LMB(X)24-SR...
NMB(X)24-SR...
AMB(X)24-SR...
GMB(X)24-SR...
LRB(X)24-SR...
ARB(X)24-SR...
LHB(X)24-SR...
AHB(X)24-SR...
LUB(X)24-SR
CMB24-SR...
GK...
NK...
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
15 LMB(X), NMB(X), AMB(X), GMB(X), LRB(X), and
CAUTION ARB(X) can be supplied with either 120 VAC or 230 VAC.
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury. It may also be used to 6 Only connect common to neg. (–) leg of control circuits.
alert against unsafe practices.
Equipment damage! 19 All 120 VAC and 230 VAC actuators use appliance rated
2 Actuators may be connected in parallel. Power cables.
consumption and input impedance must be observed. A Actuators with appliance cables are numbered.
WARNING
Live Electrical Components!
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical APPLICATION NOTES
components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical Meets cULus requirements without the need of an
components perform these tasks. Failure to follow all electrical electrical ground connection.
safety precautions when exposed to live electrical components
could result in death or serious injury. 7 A 500 Ω resistor converts the 4 to 20 mA control
signal to 2 to 10 VDC.
5
(–)
Control Signal
VDC/mA (+) Wht (3) Y Input, 2 to 10V
2 to 10 VDC (–)
Feedback Signal (+) Org (5) U Output, 2 to 10V
1 0
Hazard Identification
Warnings and Cautions appear at appropriate sections throughout INSTALLATION NOTES
this manual. Read these carefully.
3 Actuators may also be powered by 24 VDC.
CAUTION
5 Actuators with plenum rated cable do not have
Indicates a potentially hazardous situation which, if not avoided, numbers on wires; use color codes instead.
may result in minor or moderate injury. It may also be used to Actuators with appliance cables are numbered.
alert against unsafe practices.
Equipment damage!
2 Actuators may be connected in parallel. Power
consumption and input impedance must be observed.
APPLICATION NOTES
WARNING Meets cULus requirements without the need of an
Live Electrical Components! electrical ground connection.
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical
components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components
could result in death or serious injury.
2 3 5
24 VAC Transformer
…PC
* White color wire for AF24-PC US, Pink color for all others.
‡ White color wire for AF24-PC US, Orange color for all others.
Override Control
Override
AF24-ECON
W203
Wire Input Signal LF24-ECON… position Application
24 VAC Transformer 5 2
Y1 24 VAC Drive closed (0%) Morning warm-up cycle
B
Y1 Common Drive open (100%) Smoke Purge Line Blk (1) Common
N40067 - 7/11 - Subject to change. © Belimo Aircontrols (USA), Inc.
Y1 Open wire Drive to min. position Mechanical cooling in Volts Red (2) + Hot
use, RTU thermostat
calls for heat. 27 Wht (3) Y1
A Org (4) Y2 Min-pos, 0 to 10V
Y2 0 VDC to 10 VDC Min. position of 0% to 100% Override potentiometer
via a remote C02 Grn (5) U Output, 2 to 10V
sensor/controller or Default
CW CCW
DDC controller. 0
1
(–) .8
Control Signal .2
A Override
Closed (0%) 0 to 10 VDC
(+) 26 .4 .6
MIN
Override AF24-ECON-R03 US
B Open (100%) LF24-ECON-R03 US
Standard Economizer Mode Wiring 29 30 LF24-ECON-R10 US
W202
24 VAC Transformer 5 2
Line Blk (1) Common
Volts Red (2) + Hot
27 Wht (3) Y1
3 kΩ NTC* Org (4) Y2 Min-pos, 0 to 10 V
MA thermistor 28
Grn (5) U Output, 2 to 10V
setpoint 55∞F
Default
CW CCW 1
0
(–) .8
Control Signal .2
0 to 10 VDC
(+) 26 .4 .6
MIN
AF24-ECON-R03 US
LF24-ECON-R03 US
29 30 LF24-ECON-R10 US
Actuators: LF24-SR-E US
W176
21 24 VAC Transformer 5 3
Meets cULus requirements without the need of an 32 Wht (3) D Y Full Open
electrical ground connection.
21 Provide overload protection and disconnect as required. Grn (5) U Output, 2 to 10V
Default 1
.8
.4 LF24-SR-E US MIN
26 0
.2
LF24-SR-E US MIN
Volts
2
24 VAC Transformer 2
Hot Com
Blk (1) – Common
A B 1 A B 1
24 VAC Transformer 2
CCW CW
a
(–) Wht (3) Y Input
Position
Feedback VDC (+) † (5) U Output
Direction of rotation switch
CCW CW
CCW CCW
CW CW
A B 5 A B 5
TF24-MFT US 5 Org
LF24-MFT US 5 Wht Refer to page 26 for auxiliary switch (-S models) wiring.
800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN
19
Wiring for Damper Actuators and Control Valves
MFT, Spring Return, Non-Spring Return, Electronic Fail-Safe, 24V
W400_A_11
24 VAC Transformer 10 4 3 5
WARNING
Live Electrical Components!
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical
components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical APPLICATION NOTES
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components Meets cULus requirements without the need of an
could result in death or serious injury. electrical ground connection.
Controller
Triac Source
24 VAC Transformer
Line
Volts
4 5
Hot Com
Blk (1) Common
Red (2) + Hot
Wht (3) Y1 Input
Controller
Position
(–) Wht (3) Y Input
Feedback VDC
(+) Org (5) U Output
0 to 5 VDC
Wiring multiple...MFT actuators to single shaft and/or on 2 to 10 VDC
valves. All MFT actuators are wired in master-slave
configuration. CCW CW
W017
W020
24 VAC Transformer 5 Q209A
21 Minimum Position
Actuators with plenum rated cable do 21 24 VAC Transformer Potentiometer 5
5 not have numbers on wires; use color Line Blk (1) Common
Volts Red (2) + Hot Line Blk (1) Common
codes instead. Actuators with 23 Volts Red (2) + Hot
appliance cables are numbered. 23
22 W Pnk (4) W 24
Provide overload protection and Series 90
R Wht (3) R
22 B R W Pnk (4) W 25
21 disconnect as required. Controller
H205 Wht (3) R
B R W B Gry (5) B Changeover W R B
Actuators and controller must have Org (6) ‘U5’ Output 2 to 10 VDC
Controller Gry (5) B
22 separate transformers. Series 90 high limit control - 280 Ω
Org (6) ‘U5’ Output 2 to 10 VDC
-MFT95
Consult controller instruction data for 22 -MFT95
W
23 more detailed information. Shunting
Wiring Multiple Actuators to a Series 90 Controller Resistor
B
Resistor value depends on the type of Occupied
W018
Contact
24 controller and the number of 24 VAC Transformer 5 Y
21 Honeywell T675A
actuators. No resistor is used for one R
Morning Warmup
R W
actuator. Honeywell® resistor kits may Line Blk (1) Common 24
also be used. Volts Red (2) + Hot
23
W973, W7100
Controller
W015
W027
Warnings and Cautions appear at appropriate sections throughout 24 VAC Transformer
this manual. Read these carefully. 21
Line Blk (1) Common 3
CAUTION
Volts Red (2) + Hot
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury. It may also be used to Wht (3) Y Input, 6 to 9V
alert against unsafe practices. Control Signal Wht (4) Output +20 VDC
6 to 9 VDC (+)
Equipment damage! Wht (5) U Output 2 to 10V
2 Actuators may be connected in parallel. Power consumption Power to Controller
and input impedance must be observed. Wht (6) Common +20 VDC
Controller Common (–)
CW CCW
WARNING 2
Feedback 2-10 VDC
Live Electrical Components!
During installation, testing, servicing and troubleshooting of this LF24-MFT (-S) -20 US
product, it may be necessary to work with live electrical
components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical
components perform these tasks. Failure to follow all electrical Multiple LF24-MFT (-S) -20 US Actuators from One Controller
safety precautions when exposed to live electrical components
W029
could result in death or serious injury.
21 24 VAC Transformer
Line Blk (1) Common 3
Volts Red (2) + Hot
INSTALLATION NOTES
Wht (3) Y Input, 6 to 9V
Control Signal
3 Actuators may also be powered by 24 VDC 6 to 9 VDC (+) Wht (4) Output +20 VDC
21 Provide overload protection and disconnect as required. Feedback 2-10 VDC Wht (5) U Output 2 to 10V
21 24 VAC Transformer
CP-8102 1 MP-52XX
TP-810X Vac Line
2 Blk (1) Common
TP-8121 Power Black 3
TP-8124 Volts Red (2) + Hot
TP-8232 +20 (Red) Red 3
OP1 (Yellow) Yellow N.C. Wht (3) Y Input, 6 to 9V
Typical COM (Blue) Blue COM
Controller Wht (4) Output, +20 VDC
Brown N.O.
Aux.
Switch Orange Wht (5) U Output 2 to 10V
Green
1 24 Vac: Black/Blue Wht (6) Common +20 VDC
120 Vac: White CW CCW
240 Vac: White/Black
Wire cross reference 2
Belimo modulating actuators Belimo
are 24 VAC/DC, if 120 or 240 MP-52XX (SR or MFT) To other actuators
LF24-MFT (-S) -20 US
is available an external Black/Blue, Power 2, Hot
transformer is required. Black, Power 1, Com
Red, +20 4, +20 VDC
Yellow, OP1 3, Signal
2 Maximum of 2 Blue, COM 6, Com VDC
Brown, N.O. S3, N.O. “-S” type
3 MP-52XX-500 models include Orange, N.C. S2, N.C. “-S” type
internal SPDT auxiliary switch. Green, Ground Not used
VDC or 4-20mA
Hazard Identification
24 VAC Transformer Master 5
Warnings and Cautions appear at appropriate sections throughout
this manual. Read these carefully.
Line Blk (1) Common
Volts
CAUTION Red (2) + Hot
3
Indicates a potentially hazardous situation which, if not avoided, (–)
may result in minor or moderate injury. It may also be used to Control Signal
(+) Wht (3) Y Input, 2 to 10 V
2 to 10 VDC or
alert against unsafe practices. 4 to 20 mA
500 Ω
Org (5) U Output 2 to 10 V
1/4 watt
Equipment damage!
4 Actuators may be connected in parallel if not mechanically CCW CW
mounted to the same shaft. Power consumption and input
impedance must be observed.
5
WARNING Slave
Live Electrical Components!
Blk (1) Common
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical Maximum Red (2) + Hot
components. Have a qualified licensed electrician or other 4 actuators
individual who has been properly trained in handling live electrical per shaft. Wht (3) Y Input, 2 to 10 V
components perform these tasks. Failure to follow all electrical
Org (5) U
safety precautions when exposed to live electrical components
could result in death or serious injury.
CCW CW
4
INSTALLATION NOTES
each other. Meaning the master input = controllers output. Wht (3) Y1 Input 25
Master output = slave input. Slave output = controller input. Pnk (4) Y2 Input
Org (6) U Output 2 to 10 V
Example
CCW CW
Controller Master Slave Slave
Output Feedback Input Feedback -MFT
2 to 10 VDC 2 to 10 VDC 2 to 10 VDC 0 to 5 VDC 4
Actuators: EFB...-S EFX...-S AFB...-S AFX...-S AF...-S US NFB...-S NFX...-S LF...-S US TF...-S US
AMB(X)...-S LMB(X)...-S ARB(X)...-S LRB(X)...-S S1A/S2A LMB(X)...(-P5)(-P10)
1 One built-in auxiliary switch (1xSPDT), for end position Meets cULus requirements without the need of an
indication, interlock control, fan startup, etc. electrical ground connection.
Two built-in auxiliary switches (2xSPDT), for end position
13 indication, interlock control, fan startup, etc. Same voltage must be used for dual switch models.
† Either 24 VAC or line voltage, not both.
WARNING
Live Electrical Components! Auxiliary Switch Wiring for LF…-S US, TF…-S,
During installation, testing, servicing and troubleshooting of this
product, it may be necessary to work with live electrical LMB(X)24-3-S, AMB(X)24-3-S, LRB(X)24-3-S, ARB(X)24-3-S
components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical 1
components perform these tasks. Failure to follow all electrical
safety precautions when exposed to live electrical components S1
NC
could result in death or serious injury. S2
AF…-S US
Potentiometer and Auxiliary Switch Wiring for
LMB(X)24-3(-S)(-P5)(-P10)
Add on Auxiliary Switches
S1A/S2A for GMB(X), AMB(X), NMB(X), LMB(X), GRB(X),
ARB(X), NRB(X), LRB(X)
S1
S1 NC
NC
S2
S2
S3
5/10K Ω
S3 NO
NO
S4
NC
S1A S5
S6 Potentiometer Auxiliary Switch
NO
S2A
Actuators: SYx-MFT
Notes:
INSTALLATION NOTES 1. Motor CAMS have been factory calibrated and should not be moved.
2. An adaption must be performed if any limit switch is adjusted. This will
calibrate the beginning and end stopping points. Press the adaption
CAUTION button for 3 seconds and release.
MFT Connection
Control Signal +
Control Signal -
FDBK +
FDBK -
Adaption
24V
N40067 - 7/11 - Subject to change. © Belimo Aircontrols (USA), Inc.
Direction of Rotation
N
H
Control Signal +
Control Signal -
FDBK +
FDBK -
Adaption
120/230V
Direction of Rotation
LED Open
LED Close
Feedback (11)
Feedback (12)
Sensitivity
VR1
VR2
Notes:
INSTALLATION NOTES 1. Do not change sensitivity or dip switch settings with power applied!
2. VR1 and VR2 are factory calibrated and should not be moved.
CAUTION 3. Motor CAMS have been factory calibrated and should not be moved.
8 7 6 5 4 3 2 1 OFF 8 7 6 5 4 3 2 1 OFF
Dip
INPUT = 2-10 VDC RESPONSE = DIRECT
Switch
ON ON
Settings
8 7 6 5 4 3 2 1 OFF 8 7 6 5 4 3 2 1 OFF
INPUT = 4-20mA RESPONSE = REVERSE
ON ON
8 7 6 5 4 3 2 1 OFF
8 7 6 5 4 3 2 1 OFF LOSS OF SIGNAL = CLOSED
INPUT = 1-5 VDC (Direct Acting)
ON ON
LOSS OF SIGNAL = CLOSED
(Reverse Acting)
8 7 6 5 4 3 2 1 OFF 8 7 6 5 4 3 2 1 OFF
OUTPUT = 2-10 VDC LOSS OF SIGNAL = STOP
ON ON
WARNING
Hazard Identification
INSTALLATION NOTES
Warnings and Cautions appear at appropriate sections throughout
this manual. Read these carefully.
Observe class 1 and class 2 wiring restrictions.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, Transformer sizing = SY actuator draw X 1.25 (safety margin)
may result in minor or moderate injury. It may also be used to (Ex. SY2-24 requires 3.0A x 1.25 = 3.75A,
alert against unsafe practices. 3.75A X 24 VAC = 90VA Transformer).
Indicates an action or condition that may cause irreversible
damage to the actuator(s) or associated equipment.
Equipment damage! NOTES SY1…12-120V or 230V
Power consumption and input impedance must be observed.
s Caution: Power Supply Voltage
s )SOLATION RELAYS MUST BE USED IN PARALLEL CONNECTION OF MULTIPLE ACTUATORS
NOTES SY1…5-24 using a common control signal input.
s ( , CANNOT BE CONNECTED TO TERMINAL AND SIMULTANEOUSLY
Each actuator should be powered by a single, isolated s Required: 4ERMINAL NEEDS TO BE FIELD WIRED TO ENABLE HEATER CIRCUIT
33 control transformer.
s )SOLATION RELAYS MUST BE USED IN PARALLEL CONNECTION OF MULTIPLE ACTUATORS
using a common control signal input.
s ( CANNOT BE CONNECTED TO TERMINAL AND SIMULTANEOUSLY
s Required: 4ERMINAL NEEDS TO BE FIELD WIRED TO ENABLE HEATER CIRCUIT
1 Common N L1 1 Common
Line Open Open
Volts
3 Open H L2 3 Open
4 Closed 4 Closed
N40067 - 7/11 - Subject to change. © Belimo Aircontrols (USA), Inc.
Close Close
Connect to #1 for fully Connect to #1 for fully
5 open indication
5 open indication
7 HTR 7 HTR
A A
LS3 LS3
B B
A-C (Open Indication) A-C (Open Indication)
C C
D D
LS4 LS4
E E
D-F (Closed Indication) D-F (Closed Indication)
F F
Contact Rating: 5A 250 VAC Max. Contact Rating: 5A 250 VAC Max.
A LS3 A LS3
B B
A-B (Open Indication) A-B (Open Indication)
C Contact Rating: 5A 125 VAC Max.
C Contact Rating: 5A 125 VAC Max.
3A 250 VAC Max. 3A 250 VAC Max.
E LS4
E LS4
A LS3
A LS3
B B
!
"