ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE BY THE CONTRACTOR. ALL DISCREPANCIES ARE TO
BE IMMEDIATELY REPORTED TO THE ARCHITECT. CONTRACTORS ARE TO PREPARE AND SUBMIT SHOP
m DRAWINGS TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORKS. THIS DRAWING IS THE
PROPERTY OF ARCHITECT BRADLEY ROME BALTAZAR AND IS NOT TO BE REPRODUCED OR USED
WITHOUT WRITTEN CONSENT.
1.35 -REPUBLIC ACT NO. 545-
m
KEY PLAN

m
FCU -CS

2.27
5.0TR

m
3.92

09
UNIT 309

IT 3
ACCU
5.0TR

UN
m
5.70

CORING GENERAL SPECIFICATIONS ABBREVIATIONS:


PROVISION FOR
REFRIGERANT
PIPING
1. CONTRACTOR IS ADVISED TO HAVE AN ACTUAL SURVEY OF THE EXISTING CONDITION AT SITE.
m

2. ALL EQUIPMENT SHALL BE INSTALLED IN APPROPRIATE LOCATION AS SHOWN ON THE PLANS.


8.60

3. CONTRACTOR MUST SUBMIT SHOP DRAWINGS INDICATING ACTUAL EQUIPMENT DIMENSION AND OPERATING WEIGHTS. SUFFICIENT CLEARANCES TO FACILITATE NORMAL SERVICES
AND MAINTENANCE WORKS ARE PROVIDED IN THIS DESIGN PLANS. HOWEVER, SHOULD ACTUAL EQUIPMENT PHYSICAL SIZES DIFFER CONSIDERABLY FROM THOSE SHOWN IN THE PLANS,
THE CONTRACTOR SHOULD NOTIFY THE ARCHIPTECT OR DESIGN ENGINEER IMMEDIATELY IN WRITING,
m
0.98

4. ALL EQUIPMENT SHALL SET ON 150MM THICK, LEVEL REINFORCED STEEL BASE, UNLESS OTHERWISE SPECIFIED. (FOR FLOOR MOUNTED EQUIPMENT).
PROJECT TITLE
5. ALL EQUIPMENT SHALL BE MOUNTED ON OR SUPPORTED BY VIBRATION ISOLATOR OR ASSEMBLIES.

6. ALL AC UNIT CEILING CONCEALED SHALL HAVE SERVICE ACCESS TO BE PROVIDED BY THE CIVIL CONTRACTOR.

7. ALL PIPING SHALL BE LEAK TESTED WITH A PRESSURE OF AT LESAT 1 1/2 TIMES THE DESIGN WORKING PRESSURE (24 HOUSE).

8. ALL MATERIALS SHALL BE NEW AND CLEAN. SANDREALEE SALON


m

UNIT309 - 225 General Kalentong St., Brgy. DaangBakal,


2.90

9. DEVIATIONS AND REVISIONS FROM THE PLANS SHALL BE PREFFERED TO THE ARCHITECTS FOR REVIEW AND APPROVAL. Mandaluyong City

10. ALL NECESSARY GOVERNMENT PERMITS SHALL BE SECURED AND BORNE BY THIS CONTRACTOR.

11.ALL WORKS SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. CLIENT

12. THE AIR CONDITIONING AND VENTILLATION SYSTEM SHOULD BE PROPERLY BALANCE BY A SEPARATE CONTRACTOR AND TO SUBMIT BALANCING REPORT FOR EVALUATION (BY
TENANT'S CONTRACTOR).
C
SIGNAGE 13. THIS CONTRACTOR SHOULD COORDINATE HIS WORKS CLOSELY WITH THE WORKS OF OTHER TRADES.PROVISION FOT THE PIPE PASSAGES THRU WALLS SHALL BE COORDINATED IN
3.90 m 1.55 m 6.15 m
ADVANCE WITH THE BUILDING CONTRACTOR. FAILURE ON THE PART OF THIS PROVIDING THEM LATER AT HIS OWN EXPENSE.
11.60 m 14. ALL PIPING PASSING ABOVE THE CEILING LEVEL SHOULD BE PROPERLY BRACKETED. SANDREALEE SALON
15. P-TRAP IS NEEDED FOR CONDENSATE DRAIN PIPE.

AIR -CONDITIONING PLAN ARCHITECT


SCALE:1:50m
1
M 1
ARCH. BRADLEY ROME V. BALTAZAR

REG. NO. T.I.N. NO. P.T.R NO. ISSUED AT ISSUED ON


044540 700-937-019-000 BAGUIO CITY 01-21-2019
PROFESSIONAL MECHANICAL ENGINEER

REG. NO. T.I.N. NO. P.T.R NO. ISSUED AT ISSUED ON

REVISIONS

NO. DATE REMARKS

DOCUMENT TYPE

FOR BUILDING PERMIT


SHEET CONTENT

SHEET NUMBER
DRAWN BY: BRB

SCALE: AS SHOWN
M-001
CHECKED BY: BRB

PROJECT NO.: 2019 -003


APPROVED BY: BRB
DATE: JANUARY 18,2019