Vous êtes sur la page 1sur 28

Particulars Unit 500 MW CCPP Reference

Required Flow m3/hr 10 WBD


Pump flow margin 10%
Pump Flow m3/hr 11
gpm 48

Pump TDH m 80

Pump Speed rpm 3000


No. of Stage 6
Suction Type Single
Specific Speed USCS 1227
Pump Efficiency 50% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 5
Motor selection margin 10%
Design Brake Power kW 5

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 248 WBD
Pump flow margin 10%
Pump Flow m3/hr 273
gpm 1,202

Pump TDH m 80

Pump Speed rpm 3000


No. of Stage 2
Suction Type Single
Specific Speed USCS 2682
Pump Efficiency 80% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 74
Motor selection margin 10%
Design Brake Power kW 82

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 248 WBD
Pump flow margin 10%
Pump Flow m3/hr 273
gpm 1,202

Pump TDH m 80

Pump Speed rpm 3000


No. of Stage 2
Suction Type Single
Specific Speed USCS 2682
Pump Efficiency 80% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 74
Motor selection margin 10%
Design Brake Power kW 82

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 42 WBD
Pump flow margin 10%
Pump Flow m3/hr 50
gpm 220

Pump TDH m 60 Head Calculation

Pump Speed rpm 3000


No. of Stage 2
Suction Type Single
Specific Speed USCS 1424
Pump Efficiency 65% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 13
Motor selection margin 10%
Design Brake Power kW 14

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 129.1 WBD
Pump flow margin 10%
Pump Flow m3/hr 145
gpm 638

Pump TDH m 10 Head Calculation

Pump Speed rpm 1500


No. of Stage 1
Suction Type Single
Specific Speed USCS 2764
Pump Efficiency 75% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 5
Motor selection margin 10%
Design Brake Power kW 6

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 14 WBD
Pump flow margin 10%
Pump Flow m3/hr 20
gpm 88

Pump TDH m 7.5 Head Calculation

Pump Speed rpm 1500


No. of Stage 1
Suction Type Single
Specific Speed USCS 1274
Pump Efficiency 60% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 1
Motor selection margin 10%
Design Brake Power kW 1

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 26.3 WBD
Pump flow margin 10%
Pump Flow m3/hr 30
gpm 132

Pump TDH m 45 Head Calculation

Pump Speed rpm 3000


No. of Stage 2
Suction Type Single
Specific Speed USCS 1369
Pump Efficiency 60% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 6
Motor selection margin 10%
Design Brake Power kW 7

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 42 WBD
Pump flow margin 10%
Pump Flow m3/hr 50
gpm 220

Pump TDH m 40 Head Calculation

Pump Speed rpm 3000


No. of Stage 2
Suction Type Single
Specific Speed USCS 1930
Pump Efficiency 62% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 9
Motor selection margin 10%
Design Brake Power kW 10

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 495 WBD
Pump flow margin 10%
Pump Flow m3/hr 545
gpm 2,400

Pump TDH m 10 Head Calculation

Pump Speed rpm 1000


No. of Stage 1
Suction Type Double
Specific Speed USCS 2526
Pump Efficiency 85% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 17
Motor selection margin 10%
Design Brake Power kW 19

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 2500 WBD
Pump flow margin 10%
Pump Flow m3/hr 2750
gpm 12,108

Pump TDH m 27 Head Calculation

Pump Speed rpm 1000


No. of Stage 1
Suction Type Double
Specific Speed USCS 2694
Pump Efficiency 85% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 238
Motor selection margin 10%
Design Brake Power kW 262

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 2500 WBD
Pump flow margin 10%
Pump Flow m3/hr 2750
gpm 12,108

Pump TDH m 35 Head Calculation

Pump Speed rpm 1500


No. of Stage 1
Suction Type Double
Specific Speed USCS 3327
Pump Efficiency 85% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 309
Motor selection margin 10%
Design Brake Power kW 339

Number of Pump 1W+1S


Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 7766.7 WBD
Pump flow margin 5%
Pump Flow m3/hr 8155
gpm 35,905

Pump TDH m 25 Head Calculation

Pump Speed rpm 750


No. of Stage 1
Suction Type Double
Specific Speed USCS 3687
Pump Efficiency 87% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 639
Motor selection margin 10%
Design Brake Power kW 702

Number of Pump 3W+1S

Note:
CW Pump capacity includes the ACW flow as ACW Booster Pump will be used
Particulars Unit 500 MW CCPP Reference
Required Flow m3/hr 544.3 WBD
Pump flow margin 10%
Pump Flow m3/hr 600
gpm 2,642

Pump TDH m 10 Head Calculation

Pump Speed rpm 1000


No. of Stage 1
Suction Type Double
Specific Speed USCS 2651
Pump Efficiency 85% Karassik Handbook

Density of Fluid kg/m3 1000


Acceleration due to gravity m/s2 9.81
Brake Power kW 19
Motor selection margin 10%
Design Brake Power kW 21

Number of Pump 1W+1S

Vous aimerez peut-être aussi