ROSA report Page 1 of 2

Project: Enerau - Hydro ROSA 9.1 ConfigDB u399339_282


Prepared By: NP Case: 1
mft 10/25/2018

System Design Overview

69.99
Raw Water TDS 9000.00 mg/l % System Recovery (7/1)
%
Wastewater with Generic membrane filtration, SDI
Water Classification Flow Factor (Pass 1) 0.85
<3
Feed Temperature 30.0 C

Pass # Pass 1
Stage # 1
Element Type XFRLE-400/34i
Pressure Vessels per Stage 20
Elements per Pressure Vessel 6
Total Number of Elements 120
Pass Average Flux 12.42 lmh
Stage Average Flux 12.42 lmh
Permeate Back Pressure 0.00 bar
Booster Pressure 0.00 bar
Chemical Dose -
Energy Consumption 2.69 kWh/m³

Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED
OR IMPLIED,AND NO WARRANTY OF MERCHANTABILITY OR FITNESS, IS GIVEN. Neither FilmTec Corporation nor The
Dow Chemical Company assume liability for results obtained or damages incurred from the application of this information. FilmTec
Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design
software, the customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor
The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/Enerau%2... 25/10/18
ROSA report Page 2 of 2

Project: Enerau - Hydro ROSA 9.1 ConfigDB u399339_282


Prepared By: NP Case: 1
mft 10/25/2018

Pass 1
Flow Pressure TDS
Stream #
(m³/h) (bar) (mg/l)
1 79.10 0.00 9000.00
3 159.10 26.92 18656.10
4 80.00 22.49 28166.69
5 103.74 22.49 28166.69
6 23.74 22.49 28166.69
7 55.36 - 836.07
7/1 % Recovery 69.99

Project Information:
Diary WWTP

Design Warnings:
-None-

Solubility Warnings:
-None-

Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED
OR IMPLIED,AND NO WARRANTY OF MERCHANTABILITY OR FITNESS, IS GIVEN. Neither FilmTec Corporation nor The
Dow Chemical Company assume liability for results obtained or damages incurred from the application of this information. FilmTec
Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design
software, the customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor
The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/Enerau%2... 25/10/18

Vous aimerez peut-être aussi