Vous êtes sur la page 1sur 2

Project: Project No.

3 BR Chalet 141333
Part of Structure Page No. Rev.
Precast Super Structure 0
UNITED PRECAST CONCRETE DUBAI L.L.C.
P.O.Box: 52900,Dubai, U.A.E. Designed By: Date: Checked By: Date: App'd By:
Tel:(971-4)3474440(5 Lines) Output
BKE 31-Dec-14 CDP 31-Dec-14 RC
Fax:(971-4)3474746

Ref.

FOUNDATION LOADS
LOAD WEIGHT POINT TOTAL LIVE LOAD
ITEM LOAD DESCRIPTION LOAD, DL,
WIDTH, m kN/m2 kN/m kN/m2 kN/m
kN
1.0 GRID : A-3-6 (TYPICAL H-3-6, E-6-7 , G-6-7) 67.87 11.31
ROOF: 3.61 0.60 2.16
Super Imposed Dead Load 3.61 5.00 18.03
Collateral load 3.61 0.50 1.80
GROUND FLOOR 3.05 3.00 9.15
Super Imposed Dead Load 3.05 6.50 19.83
HCS Weight### mm thick 3.05 2.66 8.11
PC column 300x300 3.50 2.25 2.25
250 mm insulated 3.50 5.10 17.85
2.0 GRID : C-2-3 (Typical E-2-3) 66.03 10.91
ROOF: 3.44 0.60 2.06
Super Imposed Dead Load 3.44 5.00 17.19
Collateral load 3.44 0.50 1.72
GROUND FLOOR 2.95 3.00 8.85
Super Imposed Dead Load 2.95 6.50 19.18
HCS Weight### mm thick 2.95 2.66 7.85
PC column 300x300 3.50 2.25 2.25
250 mm insulated 3.50 5.10 17.85
3.0 GRID : C-3-5 (Typical E-3-5) 97.53 19.30
ROOF: 2.17 0.60 1.30
Super Imposed Dead Load 2.17 5.00 10.86
Collateral load 2.17 0.50 1.09
GROUND FLOOR 6.00 3.00 18.00
Super Imposed Dead Load 6.00 6.50 39.00
HCS Weight### mm thick 6.00 2.66 15.96
250 mm isolid panel 4.90 6.25 30.63
4.0 GRID : C-5-6 (Typical E-5-6) 97.33 16.38
ROOF: 4.55 0.60 2.73
Super Imposed Dead Load 4.55 5.00 22.75
Collateral load 4.55 0.50 2.28
GROUND FLOOR 4.55 3.00 13.65
Super Imposed Dead Load 4.55 6.50 29.58
HCS Weight### mm thick 4.55 2.66 12.10
250 mm isolid panel 4.90 6.25 30.63

* consider 3.5m height wall- purlin point load will be distributed for 7 m wide .
DL = 0.00 KN & LL = 13.65 KN
7.00 m 7.00 m

DL = 0.00 KN/m LL = 1.95 KN/m


Project: Project No.

3 BR Chalet 141333
Part of Structure Page No. Rev.
Precast Super Structure 0
UNITED PRECAST CONCRETE DUBAI L.L.C.
P.O.Box: 52900,Dubai, U.A.E. Designed By: Date: Checked By: Date: App'd By:
Tel:(971-4)3474440(5 Lines) Output
BKE 31-Dec-14 CDP 31-Dec-14 RC
Fax:(971-4)3474746

Ref.
FOUNDATION LOADS
FOUNDATION LOADS
LOAD WEIGHT POINT TOTAL LIVE LOAD
ITEM LOAD DESCRIPTION LOAD, DL,
WIDTH, m kN/m2 kN/m kN/m2 kN/m
kN
5.0 GRID : D-4-6 73.87 10.62
ROOF: 2.95 0.60 1.77
Super Imposed Dead Load 2.95 5.00 14.75
Collateral load 2.95 0.50 1.48
GROUND FLOOR 2.95 3.00 8.85
Super Imposed Dead Load 2.95 6.50 19.18
HCS Weight### mm thick 2.95 2.66 7.85
250 mm isolid panel 4.90 6.25 30.63
6.0 GRID : G-3-6 120.05 21.96
ROOF: 6.10 0.60 3.66
Super Imposed Dead Load 6.10 5.00 30.50
Collateral load 6.10 0.50 3.05
GROUND FLOOR 6.10 3.00 18.30
Super Imposed Dead Load 6.10 6.50 39.65
HCS Weight### mm thick 6.10 2.66 16.23
250 mm solid panel 4.90 6.25 30.63
7.0 GRID : (between 6-7 - between F-G) 59.65 1.83
ROOF: 3.05 0.60 1.83
Super Imposed Dead Load 3.05 5.00 15.25
Collateral load 3.05 0.50 1.53
GROUND FLOOR 0.00 3.00 0.00
200 mm isolid panel 4.90 5.00 24.50
150 mm isolid panel 4.90 3.75 18.38
8.0 GRID : 6-A-E (TYPICAL 6-G-H, 3-E-H , 7-E-G) 40.61 2.48
ROOF: 4.14 0.60 2.48
Super Imposed Dead Load 4.14 5.00 20.69
Collateral load 4.14 0.50 2.07
GROUND FLOOR 0.00 3.00 0.00
250 mm insulated 3.50 5.10 17.85
9.0 GRID : ALL OTHER WALLS 63.33 4.52
ROOF: 7.54 0.60 4.52
Super Imposed Dead Load 7.54 5.00 37.69
Collateral load 7.54 0.50 3.77
GROUND FLOOR 0.00 3.00 0.00
250 mm solid panel 3.50 6.25 21.88

Vous aimerez peut-être aussi