Vous êtes sur la page 1sur 8

Enterprise Power Solutions – Dc Ups

Efficient
Reliable
Compact
Scalable
Modern Businesses Demand More

Availability Efficiency Flexibility


The modernization of business Soaring energy costs are Flexible power systems are Power systems need to be
IT networks increasingly another aspect that can not important to accommodate intelligent to protect assets
involves the convergence of be ignored when looking at business growth and like expensive batteries, and
voice and data communications power system options for affordability. Convenient easy to use, but customizable
systems. The growth of converged data networks. scalability allows capital to the requirements of
this technology reflects an Network power requirements expenditure to match what any organization.
increased dependence on it can be a considerable drain on is needed without additional Businesses should consider
and consequently, controlled an organization’s bottom line. spending on excess capacity all of these attributes when
shutdowns are no longer Government initiatives are Modularity aids system considering a suitable
acceptable. Businesses rely on increasingly common and operating efficiency while network power system.
and expect continuity of service industry groups such as the safe and simple ‘plug and go’
– always. Because when it Green Grid and Climate Savers in-house installation with little
stops, so does the business. are developing guidelines or no maintenance reduces
99% uptime is no longer for best practices. They the operating costs, making
adequate so longer reserve promote new technologies for it more affordable still.
run times are necessary for lower energy consumption,
converged data networks with and basically highlight the
IP telephony as well as system/ need for greater power
data processing requirements efficiency in businesses.
which are commonly 24/7.
Why Choose Enterprise for your
IT Application Power Source?
Superior Reliability and damage. The Enterprise DC Long Reserve Run Times: size can be closely
Protection of Equipment: UPS never directly exposes matched to a growing load
When utility AC power cuts
equipment to the utility AC power demand, further
The Enterprise DC UPS out, Enterprise DC power
power. It provides the secure ensuring optimal system
architecture is inherently more systems provide long run
reliability that has been enjoyed operating efficiency and
reliable than an AC UPS. A times on battery because the
for over 100 years by the avoiding the need to over
direct link between the load and battery is connected directly
telecom industry world wide. capitalize on capacity.
the batteries at all times, avoids to the load. No conversion
any reliance on moving parts (eg is required that will tax the
switches) whose failure or delay High Efficiency: battery life; hence more power Low Maintenance:
exposes critical equipment to Fewer end-to-end power is available for the critical load. Few moving parts means
harmful transients, harmonics conversions compared to a fewer and simpler
and high switching voltages. double conversion AC UPS Convenient and Cost- maintenance requirements
Modular DC rectifiers means the Enterprise DC UPS Effective Scalability: which can usually be done
provide built in system is more efficient to operate, by in-house staff with
For more output capacity
redundancy that pre-empts producing less wasted energy the inherent safety of a
or more reserve run time,
any potential failure, ensuring in the form of heat, thus 48Vdc system, compared
adding more rectifiers or more
no single point of failure. also contributing less to the to a 230Vac system where
batteries to an Enterprise DC
demand on power for cooling. electrical contractors
DC architecture eliminates the system is cost-effective and
Using Eaton® Energy Saver are probably required.
need for system maintenance easy. The Enterprise’s modular
Rectifiers, system operating
by-pass – failure of by-pass rectifiers means that system
efficiency can exceed 96%.
protection can cause expensive

Applications: • Secure power to customer


premises equipment (CPE)
• Secure power to converged
VoIP/data networks
• Secure power to
mid-span devices
such as network termination • Redundant power • Secure power to IP routers
equipment (NTE) supply (RPS) to bolster • Secure power to PABX
• Secure power to mixed Ethernet routing switch
equipment facilities capacity (ie PoE)

AC UPS and DC UPS in series AC UPS and DC UPS in parallel

SMALL SE
SECURE AC
AC AC UPS
LARGE AC UPS E.G. SERVER
SECURE AC

AC AC-DC
BATTERIES
DC-AC SECURE AC ENTERPRISE SECURE DC
DC UPS
ENTERPRISE SSECURE
SECU DC
AC
DC UPS
E.G.
- SWITCHES/ ROUTERS
- POE MID-SPAN DEVICE
NO BATTERIES
REQUIRED
BATTERIES BATTERIES
Meeting modern ICT converged
data power requirements

Efficient
Reliable
Compact
Scalable

Enterprise features suit a


modern business environment
• Highly reliable proven DC • Safe, simple installation
architecture and telecom – 48Vdc ‘plug and go’
grade equipment auto-configuration
EPS2
• High efficiency operation • Extensive LAN/WAN
– over 96% with Energy communications capabilities
Saver Rectifiers • Sophisticated automated
• Cost effective and simple system & battery
expansion - add capacity monitoring and control
with modular increments • Compact 2U or 3U (including
• Long reserve run times distribution) rack mounting
• Maintenance-free life • Modular slim-line ‘plug
and go’ batteries
EPS5
SMARTER
ENERGY
2000W Energy All of Eaton’s modular rectifiers
offer capacity increments

Saver Rectifier that can closely match load


growth for optimal efficiency
and cost-effectiveness.
The Enterprise DC UPS
is fully compatible with All of Eaton’s rectifiers offer
Eaton’s Energy Saver DC high peak-efficiency profiles
Rectifier which offers system and very wide efficiency–load
efficiency of over 96%. profiles which further helps
to ensure the system is
operating at, or near peak
efficiency, for most loads.

Over 96% efficiency ™

2kW 48Vdc
Enterprise IT power

EFFICIENCY
100%

HIGH AND WIDE EFFICIENCY


CURVE PROFILE OF ENTERPRISE
POWER SOLUTIONS

0
0 100%
LOAD
Cost Effective Scalable Modular Architecture

Modular hot-plug rectifiers


are the key building blocks to quick, easy,
cost effective and efficient system expansion.
The modular increments of the rectifiers
permit high level system operating efficiency
for any load, and without the expense of
over investing in excess capacity.

The EPS2 power solution has capacity for up to two The EPS5 power solution has capacity for
rectifiers. Additional capacity comes from the flexibility to up to five 900W Enterprise Power Rectifiers.
fit either the 900W Enterprise, 1800W Access or 2000W As with the EPS2, just leave rectifier positions
Energy Saver rectifiers. The rectifier increments give a empty until they are needed. The 900W
total system capacity range of 900W up to 4kW. rectifier increments give a total system
capacity range of 900W up to 4.5kW.

900W Enterprise Power Rectifier 1800W Access Power Rectifier

900W Enterprise Power Rectifier

2000W Energy Saver Rectifier

Leave rectifier positions


Y ear 1

blank until you need them.


Y ear 3

Equipment rack
with space for
your equipment.
Y ear 5

Extend reserve time capacity


easily at any time with 18Ahr Add capacity easily and efficiently as your
Enterprise battery modules. network grows, with increments that
closely match requirement.
Sophisticated Control and Monitoring Makes Life Easy

The Enterprise system


controller automatically
monitors and regulates
power system and battery
variables so you don’t have
to. It provides system status
information, warnings and
alarms and it has extensive
LAN/WAN communications
capabilities to suit any
organization.

• Auto recognition and


configuration for easy
‘hot plug & go’ rectifier
setup/expansion.
• A wide range of pre-
configured yet customizable
parameters such as
alarm settings.
• Easy initial setup with
either USB or onboard • Advanced connectivity • Compatible with power
web server using our options of built-in Ethernet management tools including
free DCTools software. interface, secure web server, Eaton’s PowerManagerII™
• Intelligent automated SNMP agent and Mod-Bus. or others such as HP
battery management to • A distinctive user-friendly Open View™, 3Com
maximize battery life. high-resolution color screen Network Director™ and
with multiple page views. SNMPc™ to name a few.

Enterprise Battery Module (EBM) - Optional

The EBM is the preferred


integrated backup power
source for Enterprise
power solutions.
Providing secure power
during AC utility power
failure for anything
from orderly shutdowns
through to extended run The EBM module is slim-line Each EBM has an 18Ahr Example: One EBM
times for continuity of and rack mountable to suit capacity and is service provides >30mins run time
service. They are modular the likely applications for maintenance free for the with a 900W load (see
and easily scalable for these systems. The battery life of the battery module. diagram on back page).
increased backup capacity modules use simple ‘plug and Battery function is monitored
for a given output play’ cables for connection and controlled by the system
demand. Other battery to the Enterprise power controller for complete
options are available. solution without need for any battery protection.
specialized tools – easy to
install in an IT environment.
Technical Specifications
EPS2 and EPS5: Brief Technical Specifications Enterprise Battery Module (EBM):
AC Supply Nominal: 120V, 240V Brief Technical Specifications
Operating Range: 90V – 275V DC Output Voltage 48V nominal
Power Factor >0.99 (50 – 100% output current)

DC Output Capacity 18Ahr
Efficiency† 91 - 96.4% (50 – 100% output current) Weight 29.5kg [65lb]
DC Output Voltage Range Dimensions (H,W,D ): *

43 – 57.5V 85mm (2U), 432mm (19” mounting), 487mm


DC Output Power (maximum*)† additional space is required at the rear for cables.
*

EPS2 240VAC: APR48-ES: 4.0kW


APR48-3G: 3.6kW Typical Run time values* (see graph)
EPR48-3G: 1.8kW Battery Run Time (minutes)

EPS2 120VAC: APR48-ES: 2.3kW


APR48-3G: 2.2kW 90 9
8
EPR48-3G: 1.1kW 80 7
EPS5 240VAC: EPR48-3G: 4.5kW 6
70
EPS5 120VAC: EPR48-3G: 2.25kW 5
60 4
*
based upon 2 rectifiers fitted to the EPS2-3G and 5 rectifiers
50 3
fitted to the EPS5-3G, refer to rectifier data sheets
40 2
Operating Temperature Range 30
1
Rated: -10°C to +50°C [-14°F to +122°F]
20
Extended*: -40°C to +70°C [-40°F to +158°F]
10
Output current is derated above 50°C [122°F]
*

400 800 1200 1600 2000 2400 2800 3200 3600


Dimensions H, W, D = required number of battery modules Equipment Power (watts)

EPS2: 2U, 19” mounting, 13.2” [335mm]*


EPS5: 3U, 19” mounting, 13.2” [335mm]* *Battery times are approximate and vary
*
Additional clear depth space is required for exhaust air. depending upon factors such as:
• load configuration
DC Distribution Module
• battery charge
12-way circuit breakers (2 x Battery, 10 x Load)
• battery age and temperature
Circuit breaker type: Magnetic/Hydraulic, push fit type
Battery circuit breakers: Heinemann AC1R Series *
Other battery options available - consult your local Eaton agent.
Typical ranges available: 30A, 40A, 50A, 60A
Load circuit Breakers: Heinemann JC1S Series
Typical ranges available: 6A,10A, 15A, 20A, 25A, 30A EBM Part Ordering Codes
System Controller Extended: PW5130 48V EBM RM
SC200 Battery Module: P/N 103006587-6591

Communication Features
USB direct Enterprise System Ordering Codes
10BaseT Ethernet, TCP/IP, SNMP, On board web server Enterprise: EPS2-421-6000
RS232 to external PSTN or GSM modem (modem not included) Power System: EPS5-421-6000
Rectifier Blank Panels Battery Connection Cables
For unused rectifier positions CKBATT-02 Eaton EBM 5130 connection cable, 2000mm long.
or
DCTools
CKBATT-01 ‘other batteries’ connection cable, 2000mm long.
Configuration software.
Free download from: www.powerware.com/downloads Customer Connection Equipment Cable
CKLOAD-00 10xload cable sets, 1000mm long
PowerManagerII
Remote control and monitoring software EBM Rack Mounting Kit
Certifications Included with EBM5130 as standard
All products comply with international standards.
North America UL (Canada, USA), FCC Class B
Europe CE
Australia and New Zealand C-Tick

† Power factor, efficiency and DC output power are dependant on


In the interests of continual product improvement all
rectifier model fitted. Refer to the rectifier data sheet for further details.
specifications are subject to change without notice.

© 2010 Eaton Corporation Eaton Corporation Eaton, PowerManagerII, SiteSure,


All Rights Reserved Telecommunications Power DCTools and CellSure are trade
Printed in New Zealand Solutions Business names, trademarks, and/or service
January 2010 dc.info@eaton.com marks of Eaton Corporation or its
Form No. ENT B www.eaton.com/telecompower subsidiaries and affiliates.

Vous aimerez peut-être aussi