Vous êtes sur la page 1sur 184

C ATA LO G

Switch fuses
World class performance in the most
demanding applications

• Reliability and performance


• Safe maintenance and operation
• Proven and practical
1 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 2
INTRODUCTION TO
SWITCH FUSES

01
01
004– 008


Table of contents TYPE DESIGNIATION
KEY

02
009– 011

TECHNICAL DATA

03
012– 022

ORDERING
INFORMATION

04
023– 096

DIMENSIONAL
DRAWINGS

05
097– 162

INDEX

06
163– 182
3 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 4

01
01

Switch fuses
World class performance in the most
demanding applications
OS and OSM switch fuses by ABB have been designed to deliver world-class
performance in even the most extreme conditions. Our extensive range of reliable
switch fuses, both manual and motorized, is ensured to have your application needs
covered.

Reliable in extreme conditions Safety and protection Speed up your projects

Reliability and performance Safe maintenance and operation Proven and practical
OS switch fuses are the optimal OS switch fuses are designed for Test proven type 2 coordination tables
solution for motor protection. They personal safety as well as for reliable for the OS switch fuses are available
can be installed next to transformers process protection. When in the online 24/7. From there you can easily
in heavy industry. The contact design ON position, the interlocked fuse select the appropriate ABB components
combined with the fuse link enables protection covers cannot be removed. for motor starting and protection.These
rapid fault clearance and maintains When in the OFF position, the fuse link motor starting solutions also help
protection level even after a fault is fully isolated from both ends. Also, minimize the time needed for sizing
occurs. Our motorized switch fuses the handle is padlockable with three all the starter components and ensure
protect motors from separate padlocks for ensured safety. reliable operation after a fault occurs.
overcurrent and can be operated both
remotely and manually.
5 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
World class performance in the most
demanding applications
ABB switch fuses deliver superior performance and protection for even the most
demanding industrial applications.

OS switch fuses are ideal for


demanding applications where
continuity of operations is vital
even in case of a fault. These
devices are used for protection
in a wide range of applications.
They are often found in power
distribution boards and control
cabinet in heavy industrial use.
They are built to meet installation
requirements close to the main
transformer.

In addition to industrial, business


and residential buildings, these
switch fuses are regularly used
industrial cranes and hoists to
isolate and protect the motors.
OS switch fuses may also be found
protecting stored energy and
battery packs from potential short
circuits and safely isolate them
during maintenance.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 6

01
01

Switch fuses
World class performance in the most
demanding applications

Designed for extreme conditions


Thanks to the knife contact design, the current
flow keeps the contacts pushed firmly together
before, during and after a fault without damaging
the switch or affecting the performance of the
contacts. The contacts are self-cleaning and
maintenance free, providing a long, reliable
electrical life. In OFF- position, the fuse link is
fully isolated from both ends.
Pole structure in OFF- position

Modular design
All our switches have been designed for easy and
cost-efficient installation, maintenance and use.
The modular design enables 2-, 3- and 4-pole
installation with different position of the
switching mechanism to suit your needs and
special requirements.

Modular design

Time saving accessories


The adjustable shaft (for external handles),
mounting feet, along with snap-on auxiliary
contacts and terminal shrouds create
considerable savings in terms of installation time
and costs. For example, the shaft can be adjusted
to various installation depths, which eliminates
the need for special cutting tools. This decreases
handle installation times by up to 50%.

Adjustable shaft

Safety for personnel


The interlocking fuse covers prevent opening
while the switch is in “ON” position. The switch
fuses have contacts on both sides of the fuse. The
fuses are totally isolated in the “OFF” position,
reducing the risk of electric shock to authorized
personnel.

Interlocking fuse covers


7 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses 20…1250 A
Designed to deliver
Manual operated switch fuses 20...1250 A product range:

Switch size [A] 20 25 30 32 40 32 50 60 63 100 125 160 100 200 250


DIN - OS40FD OS32GD OS125GD OS200D
- OS63GD OS160GD OS250D
BS OS20FB OS32GB OS100GB OS200B
OS32FB OS63GB OS125GB OS250B
OS160GB
NFC OS25FF OS50GF OS125GF
OS32FF
UL98 File #E101914 OS30FACC OS60GJ
OS30FAJ OS100GJ
AC23/400V [kW] 11 15 18.5 15 22 30 55 75 110 140
AC23/415V [kW] 7.5 15 15 30 55 55 75 110 145
480 V [HP] 15 30 60
600 V [HP] 20 50 75

Switch size [A] 200 315 400 600 630 800 1200 1250
DIN OS400D OS630D OS1250D
OS800D
BS OS315B OS630B OS1250B
OS400B OS800B
UL98 File# E101914 OS200J OS400J OS600J OS1200L
OS800L
AC23/400V [kW] 230 355 450 560
AC23/415V [kW] 180 230 355 450 560
480 V [HP] 150 250 400 500 -
600 V [HP] 200 250 500 600 -

Please note that accessories are not automatically included in your order. See available accessories from pages 65-67 and
ordering information from pages 69-96
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 8

01
01

Motorized switch fuses 32…1250 A
Ideal for remote use
Motorized switch fuses 32...1250 A product range:

Switch size [A] 32 50 63 100 125 160 200 250


DIN OSM32GD OSM125GD OSM200D
OSM63GD OSM160GD OSM250D
BS OSM32GB OSM100GB OSM200B
OSM63GB OSM125GB OSM250B
OSM160GB

Switch size [A] 315 400 630 800 800 1250


DI N O SM400D OSM630D OSM1 250D
OSM800D
BS O S M315B OSM630B OSM1 250B
O S M400B OSM800B

Please note that accessories are not automatically included in your order. See available accessories from page 65-67 and
ordering information from pages 82-84, 86-88 and 92-93.
9 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses 20…40 A (OS Mini)
Type designation key

Type codes
Understanding the type code keys below will help you quickly identify the correct
product for your needs. The simple naming system allows you to see the products type,
Ampere rating, standard classification and number of poles, all in one glance.

Explanation of the types OS20…40

OS 25F F _ 22 10 N1 -2
1 2 3 4 5 6 7 8

1 Brand Pole configuration table


OS ABB switch fuse/fusible switch The various placing options of the
2 Switch size / Ampere rating operating mechanism in relation to
20...40F Mini, 20…40 A the 3 or 4 poles is illustrated below.
3 Fuse type The operating mechanism may be placed at
D DIN the end of the switch or between poles.
B BS
F NFC
AJ J Between the poles OS_12 or 22:
ACC CC
4 Switch operation
Blank Front operation
S Side operation
5 Number of poles and placing
of the operating mechanism
12 3 poles, operating mechanism between the poles
22 4 poles, operating mechanism between the poles
3 poles, operating mechanism at the right end of the
30
switch
Side operated types OS_30 or 40 / OS_03 or 04:
6 Fuse size
A1, A2 BS88, A1, A2
000 DIN 000
10, 14 NFC 10x38, 14x51
7 Fourth pole/neutral terminal
N1 Non-fused switched neutral on the left side
F Fused switched neutral
Blank Terminal not included
8 Included handle
Blank No handle included, OSFAJ_ and OS30FACC_
Pistol handle and shaft included with OS40FD_, OS20FB_,
Blank
OS32FB_, OS25FF_ and OS32FF_
Pistol handle and shaft included with OSFAJ_ and
P
OS30FACC_
No handle included with OS40FD_, OS20FB_, OS32FB_,
-2
OS25FF_ and OS32FF_
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 10


Manual operated switch fuses 32…1250 A
Type designation key

02
Type codes
Understanding the type code keys below will help you quickly identify the correct
product for your needs. The simple naming system allows you to see the products type,
Ampere rating, standard classification and number of poles, all in one glance.

Explanation of the types OS32…1250 A

OS 125G D _ 04 N2 _ P
1 2 3 4 5 6 7 8

1 Brand Pole configuration table


OS ABB switch fuse/fusible switch The various placing options of the
2 Switch size / Ampere rating operating mechanism in relation to
32G…160G Gamma, 32A…160A the 3 or 4 poles is illustrated below.
200…1250 200A…1250 A The operating mechanism may be placed at
3 Fuse type the end of the switch or between poles.
D DIN
B BS
At the end of the switch fuse OS_03 or 04:
F NFC
J J
L L
4 Switch operation
Blank Front operation
S Side operation
5 Number of poles and placing
of the operating mechanism Between the poles OS_12 or 22:
03 3 poles, operating mechanism at the left end of the switch
04 4 poles, operating mechanism at the left end of the switch
12 3 poles, operating mechanism between the poles
22 4 poles, operating mechanism between the poles
3 poles, operating mechanism at the right end of the
30
switch
4 poles, operating mechanism at the right end of the
40
switch
Side operated types OS_30 or 40 / OS_03 or 04:
6 Fourth pole/neutral terminal
Blank Neutral terminal not included
N1 Non-fused switched neutral on the left side
N2 Non-fused switched neutral on the right side
N3 Includes a detachable neutral link integrated
into the mechanism
F Fused switch neutral
7 Terminals for special connection (only IEC)
BB-types:
Blank No special connection
BB Back in, back out
N N
LR Left in, right out
8 Included handle
LR-types:
Blank No handle included
P Pistol handle and shaft N

K Direct mount handle N N


11 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motorized switch fuses 32…1250 A
Type designation key

Type codes
Understanding the type code keys below will help you quickly identify the correct
product for your needs. The simple naming system allows you to see the products type,
Ampere rating, standard classification and number of poles, all in one glance.

Explanation of the types OS20…40

OSM 125G B 4 N1 M230C


1 2 3 4 5 6

1 Brand Pole configuration table


OSM ABB motorized switch fuse The various placing options of the
2 Switch size / Ampere rating operating mechanism in relation to
32G…200G Gamma, 32A…200A the 3 or 4 poles is illustrated below.
200…1250 200A…1250 A
3 Fuse type
D DIN
B BS At the end of the switch fuse OSM_03 or 04:
4 Number of poles
3 3 poles, motor operator at the left end of the switch
4 4 poles, motor operator at the left end of the switch
5 Fourth pole/neutral terminal
Blank Neutral terminal not included
N1 Non-fused switched neutral on the left side
N2 Non-fused switched neutral on the right side
Includes a detachable neutral link integrated into the
N3
mechanism
6 Motor operator voltage
230C 230 V AC
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 12


Manual operated switch fuses, IEC
Technical data for OS Mini 20...40 A

Technical data according to IEC 60947-3

Switch type OS Mini 20 OS Mini 25 OS Mini 32 OS Mini 40


Rated insulation voltage 1000 V 1000 V 1000 V 1000 V
Pollution degree 3 50 Hz 1min.
Dielectric strength 10 kV 10 kV 10 kV 10 kV
Rated impulse withstand voltage 12 kV 12 kV 12 kV 12 kV
Rated thermal current in ambient In open air 20 A/ 3.5 W 25 A/3.5 W 32 A/3.5 W 40 A/4.5 W
35 °C and temporarily 40 °C 1) / In enclosure 2) 20 A/ 3.5 W 25 A/3.5 W 32 A/3.5 W 40 A/4.5 W

03
max. fuse power dissipation Cu
In enclosure with solid links 32 A 32 A 32 A 40 A
...with minimum cable cross section 2.5 mm2 4 mm2 6 mm2 10 mm2
Power loss / pole With rated current, without fuse 1.3 W 1.3 W 2W 3.5 W
Derating, mounting on wall horizontal fuses In open air or ventilated enclosure 0% 0% 0%
Totally enclosed 5% 5% 5% 5%
Derating, mounting on ceiling 10 % 10 % 10 % 10 %
Derating at 60 ˚C In open air / in enclosure 20/ 20 % 20/20 % 20/20 % 20/20 %
Rated operational voltage AC-20 and DC-20 1000 V 1000 V 1000 V 1000 V
Rated operational current, AC-21A up to 500 V 20 A 25 A 32 A 40 A
690 V 20 A 25 A 32 A 40 A
Rated operational current, AC-22A up to 500 V 20 A 25 A 32 A 40 A
690 V 20 A 25 A 32 A 40 A
Rated operational current, AC-23A up to 500 V 20 A 25 A 32 A 40 A
690 V 20 A 25 A 32 A 40 A
Rated operational current / 48 V 20 A/2 25 A/2 32 A/2 32 A/2
poles in series DC-21A 110-220 V 20 A/2 25 A/2 32 A/2 32 A/2
440 V 20 A/4 25 A/4 25 A/4 32 A/4
Rated operational current / 48 V 20 A/2 25 A/2 32 A/2 32 A/2
poles in series DC-22A 110-220 V 20 A/2 25 A/2 32 A/2 32 A/2
440 V 20 A/4 25 A/4 32 A/4 32 A/4
Rated operational current / 48 V 20 A/2 25 A/2 32 A/2 32 A/2
poles in series DC-23A 110-220 V 20 A/2 25 A/2 32 A/2 32 A/2
440 V 20 A/4 25 A/4 32 A/4 32 A/4
Rated operational power, AC-23 2) 230 V 5.5 kW 5.5 kW 7.5 kW 11 kW
The kW-ratings are accurate for three- 400 V 7.5 kW 11 kW 15 kW 18.5 kW
phase 1500 R.P.M. 415 V 7.5 kW 11 kW 15 kW 18.5 kW
standard asynchronous motors. 500 V 11 kW 15 kW 18.5 kW 22 kW
690 V 15 kW 22 kW 22 kW 30 kW
Rated breaking capacity in category AC-23 ≤ 690 V 256 A 256 A 256 A 320 A
Rated breaking capacity / up to 220 V 128/2 128/2 128/2 128/2
poles in series in category DC-23 440 V 128/4 128/4 128/4 128/4
Rated conditional short-circuit current at prospective SC-current 80 kA, 415 V 9 kA 9 kA 9 kA 9 kA
Ip (r.m.s.) and corresponding max.
allowed cut-off current îc at prospective SC-current 100 kA, 500 V 8 kA 8 kA 8 kA 8 kA

The cut-off current îc refers to values at prospective SC-current 50 kA, 7 kA 7 kA 7 kA 7 kA


listed by fuse manufacturers 690 V
(single phase test acc. to IEC60269). at prospective SC-current 80 kA, 7.5 kA 7.5 kA 7.5 kA 7.5 kA
690 V
Rated short-time withstand current, 1 s. r.m.s. -value 1 kA 1 kA 1 kA 1 kA
Rated capacitor power The capacitor rating of 400 V 10 kVAr 12.5 kVAr 15 kVAr 15 kVAr
when no initial charge on the capacitor the switch-fuse is limited 415 V 10 kVAr 12 kVAr 15 kVAr 15 kVAr
by the fuse link. 690 V 15 kVAr 20 kVAr 25 kVAr 25 kVAr
Mechanical endurance Divide by two for operation cycles 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper.
Fuse types, IEC 60269-2 DIN 43620 000
NFC 63210, 63211 10x38 14x51
BS 88-2, -6 A1 A1, A2
distance of fuse-link bolts M4/44.5 mm M4/45.5 mm(A1)
distance of fuse-link bolts M4/73 mm (A2)
Cable size Cu 0.75...10 mm2 0.75...10 mm2 0.75...10 mm2 0.75...10 mm2
Terminal tightening torque Counter torque required 2 Nm 2 Nm 2 Nm 2 Nm
Fuse-links bolts tightening torque 2 Nm 2 Nm
Operating torque Typical for 3-pole switch fuses 3 Nm 3 Nm 3 Nm 3 Nm
1)
Acc. to IEC 60957-2, IEC 60947-1, § 6.1.1. Minimum ambient temperature -5 °C. Category B: -5 °C...-35 °C.
2)
Some fuse links limit these figures further. Starting current characteristics must be considered separately.
13 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Technical data for OS32...160G

Technical data according to IEC 60947-3

Switch type OS_32G OS_50G OS_63G OS_100G OS_125G OS_160G


Rated insulation voltage 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Dielectric strength Pollution degree 3 50 Hz 1min. 10 kV 10 kV 10 kV 10 kV 10 kV 10 kV
Rated impulse withstand voltage 12 kV 12 kV 12 kV 8 kV 8 kV 8 kV
Rated thermal current in ambient In open air 32 A/7.5 W 50 A/7.5 W 63 A/7.5 W 100 A/12 W 125 A/12 W 160 A/12 W
35 °C and temporarily 40 °C1) / 32 A/7.5 W 50 A/7.5 W 63 A/7.5 W 100 A/12 W 125 A/12 W 160 A/12 W
In enclosure
max. fuse power dissipation
...with minimum cable cross section Cu 6 mm 2
10 mm 2
16 mm 2
50 mm 2
50 mm 2
70 mm2
Power loss / pole With rated current, without fuse 1W 2.5 W 4W 4W 5W 9W
Derating, mounting on wall horizontal fuses In open air or ventilated 0% 0% 0% 0% 0% 0%
enclosure
Totally enclosed 5% 5% 5% 5% 5% 5%
Derating, mounting on ceiling 10 % 10 % 10 % 10 % 10 % 10 %
Derating at 60˚C In open air/ in enclosure 20/20 % 20/20 % 20/20 % 20/20 % 20/20 % 20/20 %
Rated operational voltage AC-20 and DC-20 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Rated operational current, AC-21A up to 500 V 32 A 50 A 63 A 100 A 125 A 160 A
690 V 32 A 50 A 63 A 100 A 125 A 160 A
Rated operational current, AC-22A up to 500 V 32 A 50 A 63 A 100 A 125 A 160 A
690 V 32 A 50 A 63 A 100 A 125 A 160 A
Rated operational current, AC-23A up to 500 V 32 A 50 A 63 A 100 A 125 A 160 A
690 V 32 A 50 A 63 A 100 A 125 A 160 A
Rated operational current / poles in series DC-21A 48 V 32 A/2 50 A/2 63 A/2 100 A/2 125 A/2 160 A/2
110-220 V 32 A/2* 50 A/2* 63 A/2* 100 A/2* 125 A/2* 125 A/2*
440 V 32 A/4* 50 A/4* 50 A/4* 100 A/4* 125 A/4* 125 A/4*
Rated operational current / poles in series DC-22A 48 V 32 A/2 50 A/2 63 A/2 100 A/2 125 A/2 160 A/2
110-220 V 32 A/2* 50 A/2* 63 A/2* 100 A/2* 125 A/2* 125 A/2*
Rated operational current / poles in series DC-23A 48 V 32 A/2 50 A/2 63 A/2 100 A/2 125 A/2 160 A/2
110-220 V 32 A/2* 50 A/2* 63 A/2* 100 A/2* 125 A/2* 125 A/2*
Rated operational power, AC-232) 230 V 7.5 kW 11 kW 18.5 kW 30 kW 37 kW 45 kW
The kW-ratings are accurate for 400 V 15 kW 22 kW 30 kW 55 kW 55 kW 75 kW
three-phase 1500 R.P.M. 415 V 15 kW 22 kW 30 kW 55 kW 55 kW 75 kW
standard asynchronous motors. 500 V 18.5 kW 30 kW 37 kW 55 kW 75 kW 90 kW
690 V 22 kW 37 kW 55 kW 90 kW 110 kW 132 kW
Rated breaking capacity in category AC-23 ≤ 690 V 504 A 504 A 504 A 1280 A 1280 A 1280 A
Rated breaking capacity / poles in series up to 220 V 252 A/2 252 A/2 252 A/2 640 A/2 640 A/2 640 A/2
in category DC-23
Rated conditional short-circuit current at prospective SC-current 80 kA, 13.5 kA 13.5 kA 13.5 kA 23.5 kA 23.5 kA 23.5 kA
Ip (r.m.s.) and corresponding max. Max OFA_ fuse size gG/aM 415 V 80/63 A 80/63 A 80/63 A 160/160 A 160/160 A 160/160 A
allowed cut-off current îc at prospective SC-current 100 kA, 12.5 kA 12.5 kA 12.5 kA 25.5 kA 25.5 kA 25.5 kA
Max OFA_ fuse size gG/aM 500 V 63/50 A 63/50 A 63/50 A 160/160 A 160/160 A 160/160 A
The cut-off current îc refers to values at prospective SC-current 50 kA, 9.5 kA 9.5 kA 9.5 kA 17.5 kA 17.5 kA 17.5 kA
listed by fuse manufacturers Max OFA_ fuse size gG/aM 690 V 63/50 A 63/50 A 63/50 A 125/160 A 125/160 A 125/160 A
(single phase test acc. to IEC60269).
at prospective SC-current 80 kA, 11.5 kA 11.5 kA 11.5 kA 20.5 kA 20.5 kA 20.5 kA
Max OFA_ fuse size gG/aM 690 V 50/50 A 50/50 A 50/50 A 125/160 A 125/160 A 125/160 A
Rated short-time withstand current, 1 s. r.m.s. -value 2.5 kA 2.5 kA 2.5 kA 5 kA 5 kA 5 kA
Rated capacitor power The capacitor rating of the 400 V 15 kVAr 20 kVAr 25 kVAr 40 kVAr 50 kVAr 60 kVAr
when no initial charge on the capacitor switch-fuse is limited by 415 V 15 kVAr 25 kVAr 32 kVAr 42 kVAr 55 kVAr 65 kVAr
the fuse link. 690 V 25 kVAr 42 kVAr 50 kVAr 75 kVAr 90 kVAr 100 kVAr
Mechanical endurance Divide by two for operation cycles 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 16 000 Oper. 16 000 Oper.
Fuse types, IEC 60269-2 DIN 43620 0006) 0006) 000,006) 000,006)
NFC 63210, 63211 14x51 22x58
BS 88-2, -6 A2-A35) A2-A33) A2-A44) A2-A44) A2-A44)
distance of fuse-link bolts M5/73 mm M5/73 mm M5/73 mm M5/73 mm M5/73 mm
distance of fuse-link bolts M8/94 mm M8/94 mm M8/94 mm
Cable size Cu 2.5...25 mm2 2.5...25 mm2 2.5...25 mm2
Terminal tightening torque 3/4 Nm 5) 3/4 Nm 5) 3/4 Nm 5) 15-22 Nm 15-22 Nm 15-22 Nm
Fuse-links bolts tightening torque Counter torque required 3.5 Nm 3.5 Nm M5:3.5 Nm M5:3.5 Nm M5:3.5 Nm
M8:5 Nm M8:5 Nm M8:5 Nm
Operating torque Typical for 3-pole switch fuses 5 Nm 5 Nm 5 Nm 7 Nm 7 Nm 7 Nm
* = Utilization category B.
1)
Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C. Category B: -5°C...-35°C.
2)
Some fuse links limit these figures further. Starting current characteristics must be considered separately.
3)
Max. fuse body diam. 22 mm.
4)
Max. fuse body diam. 32 mm.
5)
3 Nm with cable sizes 2.5...6 mm2, 4 Nm with cable sizes 10...25 mm2.
6)
Max. allowed fuse-link knife heigt is 15 mm.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 14


Manual operated switch fuses, IEC
Technical data for OS200...400

Technical data according to IEC 60947-3

Switch type OS_200GB OS_200_ OS_250_ OS_315_ OS_400_


Rated insulation voltage and rated 50 Hz
operational voltage AC-20 and DC-20 1min. 1000 V 1000 V 1000 V 1000 V 1000 V
Pollution degree 3
Dielectric strength 10 kV 10 kV 10 kV 10 kV 10 kV
Rated impulse withstand voltage 8 kV 12 kV 12 kV 12 kV 12 kV
Rated thermal current in ambient In open air 200 A/14 W 200 A/17 W 250 A/23 W 315 A/32 W 400 A/45 W

03
35 °C and temporarily 40 °C1) / In enclosure 200 A/14 W 200 A/15 W 250 A/20 W 315 A/32 W 400 A/30 W
max. fuse power dissipation
...with minimum cable cross section Cu 70 mm2 95 mm2 120 mm2 185 mm2 240 mm2
Derating, mounting on In open air or ventilated enclosure 0% 0% 0% 0% 4%
wall horizontal fuses Totally enclosed 5% 5% 5% 5% 8%
Derating, mounting on ceiling 10 % 10 % 10 % 10 % 10 %
Derating at 60 °C In open air / in enclosure 20/20 % 20/20 % 20/20% 20/20 % 20/20 %
Power loss / pole With rated current, without fuse 9W 8W 13 W 19 W 30 W
Rated operational current AC-22B ≤ 415 V 200 A
Rated operational current AC-21A ≤ 500 V 160 A 200 A 250 A 315 A 400 A
690 V 160 A 200 A 250 A 315 A 400 A
Rated operational current AC-22A ≤ 415 V 160 A 200 A 250 A 315 A 400 A
500 V 160 A 200 A 250 A 315 A 400 A
690 V 160 A 200 A 250 A 315 A 400 A
Rated operational current AC-23A ≤ 415 V 160 A 200 A 250 A 315 A 400 A
500 V 160 A 200 A 250 A 315 A 400 A
690 V 160 A 200 A 250 A 315 A 400 A
Rated operational current / ≤ 220 V 125 A/2 2) 200 A/1 250 A/1 315 A/2 400 A/2
poles in series DC-21A, 440 V 125 A/4 2) 200 A/2 250 A/2 315 A/3* 400 A/3*
DC-22A and DC-23A 660 V 200 A/3 250 A/3 315 A/4* 400 A/4*
750 V 180 A/4 230 A/4 315 A/4* 400 A/4*
880 V 180 A/4 230 A/4
Rated operational power AC-233) 230 V 45 kW 60 kW 75 kW 100 kW 132 kW
400 V 75 kW 110 kW 140 kW 160 kW 220 kW
415 V 75 kW 110 kW 145 kW 180 kW 230 kW
500 V 90 kW 132 kW 170 kW 220 kW 280 kW
690 V 132 kW 200 kW 250 kW 315 kW 400 kW
Rated breaking capacity AC-23 ≤ 690 V 1280 A 1600 A 2000 A 3200 A 3200 A
Rated conditional short-circuit at prospective SC-current 80 kA, 23.5 kA 35 kA 40.5 kA 59 kA
current Ip (r.m.s.) Max. OFA_ fuse size gG/aM 415 V 160/160 A 250/200 A 355/315 A 500/500 A
and corresponding max. at prospective SC-current 100 kA, 25.5 kA 37.5 kA 37.5 kA 63.5 kA
allowed cut-off current îc Max. OFA_ fuse size gG/aM 500 V 160/160 A 250/200 A 250/250 A 500/500 A
at prospective SC-current 80 kA, 20.5 kA 25 kA 32.5 kA 46 kA
The cut-off current îc refers Max. OFA_ fuse size gG/aM 690 V 125/160 A 160/-A 200/250 A 315/400 A
to values listed by fuse
at prospective SC-current 50 kA, 17.5 kA 28 kA 28 kA 44 kA 44 kA
manufacturers (single phase
Max. BS fuse size gG/gM 415 V 125/160 A 200/200M315 250/200M315 400/400M500 400/400M500
test acc. to IEC60269).
Rated short-time withstand at prospective SC-current 80 kA, 20.5 kA 28 kA 28 kA 48 kA 48 kA
current, 1s. Max. BS fuse size gG/gM 690 V 125/160 A 200/200M250 A 250/200M250 A 400/400M450 A 400/400M450 A
r.m.s. -value 5 kA 8 kA 8 kA 14 kA 14 kA
Max. distance from switch frame 150 mm 150 mm 150 mm 150 mm 150 mm
to nearest busbar/cable support
Rated capacitor power 400 V 60 kVAr 90 kVAr 105 kVAr 145 kVAr 180 kVAr
when no initial charge of the capacitor The capacitor ratings of 415 V 65 kVAr 100 kVAr 115 kVAr 160 kVAr 200 kVAr
the switch-fuses are limited
500 V 120 kVAr 135 kVAr 175 kVAr 215 kVAr
by the fuse links
690 V 100 kVAr 160 kVAr 190 kVAr 250 kVAr 325 kVAr
Mechanical endurance Divide by two for operation cycles 16 000 Oper. 20 000 Oper. 20 000 Oper. 16 000 Oper. 16 000 Oper.
Fuse types, IEC 60269-2 DIN 43620 06) 0-16) 0-27)
NFC 0-3 Ref.A, 4a Ref.B 1 1 2
BS 88-2, -6 A2-A4 B1-B2 B1-B34) B1-B45) B1-B45)
M5/73, mm M6/111 mm M8/111 mm M8/111 mm M8/111 mm
Size / distance of fuse-link bolts
M8/94 mm
Terminal tightening torque 15-22 Nm 15-22 Nm 30-44 Nm 30-44 Nm 30-44 Nm
Fuse-links bolts tightening torque Counter torque required M5:3.5 Nm 4 Nm 5 Nm 20 Nm 20 Nm
M8:5 Nm
Operating torque Typical for 3-pole switch fuses 7 Nm 7 Nm 7 Nm 19 Nm 19 Nm
* = Utilization category B. 4)
Max. fuse body diam 52 mm.
1)
Acc. to IEC 60957-2, IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C. Category B: -5°C...-35°C. 5)
Max. fuse body diam 62 mm.
2)
Utilization category DC21-B. 6)
Max. allowed fuse-link knife height is 21 mm.
3)
These values are given for guidance and may vary acc. to the motor manufacturer. 7)
Max. allowed fuse-link knife height is 27 mm.
15 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Technical data for OS630...1250

Technical data according to IEC 60947-3

Switch type OS_630_ OS_800_ OS_1250_


Rated insulation voltage and rated operational
voltage AC-20 and DC-20 1000 V 1000 V 1000 V
Pollution degree 3 50 Hz 1min.
Dielectric strength 10 kV 10 kV 10 kV
Rated impulse withstand voltage 12 kV 12 kV 12 kV
Rated thermal current in In open air 630 A/60 W 800 A/65 W 1250 A/110 W
ambient 35 °C and temporarily in 40 °C1) / In enclosure 570 A/50 W 720 A/55 W 1000 A/85 W
max. fuse power dissipation

...with minimum cable cross section Cu 2 x 185 mm2 2 x 240 mm2 2 x 400 mm2
Derating, mounting on In open air or ventilated enclosure 0% 4% 4%
wall horizontal fuses Totally enclosed 5% 8% 8%
Derating, mounting on 'ceiling' 10 % 10 % 10 %
Derating at 60 °C In open air / in enclosure 20/20 % 20/20 % 20/20 %
Power loss / pole With rated current, without fuse 46 W 75 W 75 W
Rated operational current AC-21A ≤ 500 V 630 A 800 A 1250 A 2)
690 V 630 A 800 A 1250 A 2)
Rated operational current AC-22A ≤ 415 V 630 A 800 A 1250 A
500 V 630 A 800 A 1250 A 2)
690 V 630 A 800 A 1250 A 2)
Rated operational current AC-23A ≤ 415 V 630 A 800 A 1000 A
500 V 630 A 800 A 1000 A 2)
690 V 630 A 800 A 1000 A 2)
Rated operational current / ≤ 220 V 630 A/1* 800 A/1*
poles in series DC-21A, DC-22A and DC-23A 440 V 630 A/2* 800 A/2*
660 V 630 A/3* 720 A/3*
750 V 630 A/4* 720 A/4*
880 V 630 A/4* 720 A/4*
Rated operational power AC-233) 230 V 200 kW 250 kW 315 kW
400 V 355 kW 450 kW 560 kW
415 V 355 kW 450 kW 560 kW
500 V 450 kW 560 kW 710 kW
690 V 630 kW 710 kW 1000 kW
Rated breaking capacity AC-23 ≤ 690 V 6400 A 6400 A 8000 A
Rated conditional short circuit current at prospective SC-current 80 kA, 77 kA 77 kA 89 kA
Ip (r.m.s.) and corresponding max. Max. OFA_ fuse size gG/aM 415 V 800/800 A 800/800 A 1250/1250 A
allowed cut-off current îc at prospective SC-current 100 kA, 83 kA 83 kA 105 kA
Max. OFA_ fuse size gG/aM 500 V 800/800 A 800/800 A 1250/-A
The cut-off current îc refers to values at prospective SC-current 80 kA, 55 kA 55 kA 88 kA
listed by fuse manufacturers Max. OFA_ fuse size gG/aM 690 V 500/630 A 500/630 A 1000/1000 A
(single phase test acc. to IEC60269)
at prospective SC-current 50 kA, 67 kA 67 kA 90 kA
Rated short-time withstand current, 1s.
Max. BS fuse size gG/gM 415 V
r.m.s. -value 18 kA 18 kA 40 kA
Max. distance from switch frame 150 mm 150 mm 150 mm
to nearest busbar/cable support
Rated capacitor power 400 V 250 kVAr 310 kVAr 440 kVAr
when no initial charge of the capacitor The capacitor ratings of the
415 V 270 kVAr 340 kVAr 460 kVAr
switch-fuses are limited by
500 V 300 kVAr 375 kVAr 550 kVAr
the fuse links
690 V 450 kVAr 550 kVAr 750 kVAr
Mechanical endurance Divide by two for operation cycles 10 000 Oper. 6000 Oper. 6000 Oper.
Fuse types, IEC 60269-2 DIN 43620 34) 34) 4, 4 a
NFC 0-3 Ref.A, 4a Ref.B 3 3 4a
BS 88-2, 6 C1-C2 C1-C3 D1
Size / distance of fuse-link bolts M10/133, 184 mm M10/133, 184 mm 2xM12/149 mm
Terminal tightening torque Counter torque required 50-75 Nm 50-75 Nm 50-75 Nm
Fuse-links bolts tightening torque M10:30 Nm M12:40 Nm M10:30 Nm M12:40 Nm M12:40 Nm
Operating torque Typical for 3-pole switch fuses 38 Nm 38 Nm 65 Nm
*
= Utilization category B.
1)
Acc. to IEC 60957-2, IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C. Category B: -5°C...-35°C.
2)
Category B.
3)
These values are given for guidance and may vary acc. to the motor manufacturer.
4)
Max. allowed fuse-link knife heigt is 35 mm.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 16


Special connected switch fuses, IEC
Technical data for OS125...200

Technical data according to IEC 60947-3

Switch type OS_125G OS_160G OS_200


Rated insulation voltage and
rated operational voltage AC-20 and DC-20 1000 V 1000 V 1000 V
Pollution degree 3 50 Hz 1min.
Dielectric strength 10 kV 10 kV 10 kV
Rated impulse withstand voltage 8 kV 8 kV 12 kV
Rated thermal current in ambient 35 °C 125 A/12 W 160 A/12 W 200 A/17 W

03
and temporarily 40 °C1) / max. fuse power dissipation
...with minimum cable cross section 50 mm2 70 mm2 95 mm2
Derating, mounting on In open air or ventilated enclosure 0% 0% 0%
wall horizontal fuses Totally enclosed 5% 5% 5%
Derating, mounting on ceiling 10 % 10 % 10 %
Derating at 60 °C In open air / in enclosure 20/20 % 20/20 % 20/20 %
Power loss / pole With rated current, without fuse BB 5W 9W 8W
LR 11 W
Rated operational current AC-21A, AC-22A and AC-23A Up to 690V 125 A 160 A 200 A
Rated operational current /poles in series 48V 125 A/2 160 A/2 200 A/1
DC-21A, DC-22A and DC-23A 110-220V 125 A/2 125 A/2* 200 A/1
440V 125 A/4*(DC-21A) 125 A/4*(DC-21A) 200 A/2
660V 200 A/3
750V 180 A/4
880V 180 A/4
Rated operational power AC-232) The kW-ratings are accurate for 230 V 37 kW 45 kW 60 kW
three-phase 1500 R.P.M standard 400 V/415 V 55/55 kW 75/75 kW 100/110 kW
asynchronous motors. 500 V/690 V 75/110 kW 90/132 kW 140/180 kW
Rated breaking capacity in category AC-23 up to 690 V 1280 A 1280 A 1600 A
Rated breaking capacity/poles in series in category DC-23 up to 220V 640 A/2 640 A/2
Rated conditional short-circuit current Ip (r.m.s.) at prospective SC-current 23.5 kA 23.5 kA
80 kA, 415 V
and corresponding max. allowed cut-off current îc Max OFA_ fuse size gG/aM 160/160 A 160/160 A
The cut-off current îc refers to values listed by at prospective SC-current 25.5 kA 25.5 kA 30 kA
fuse manufacturers5) 100 kA, 500 V
Max OFA_ fuse size gG/aM 160/160 A 160/160 A 200/200 A 6)
(single phase test acc. to IEC60269) at prospective SC-current 17.5 kA 17.5 kA 20 kA
50 kA, 690 V
Max OFA_ fuse size gG/aM 125/160 A 125/160 A 160/- A
at prospective SC-current 20.5 kA 20.5 kA 25 kA
80 kA, 690 V
Max OFA_ fuse size gG/aM 125/160 A 125/160 A 160/- A 6)
Rated short-time withstand current, 1s. r.m.s. -value 5 kA 5 kA 8 kA
Max. distance from switch frame 150 mm
to nearest busbar/cable support
Rated capacitor power The capacitor ratings of the switch-fuses 400 V/415 V 50/55 kVAr 60/65 kVAr
when no initial charge of the capacitor are limited by the fuse links 690 V 90 kVAr 100 kVAr
Mechanical endurance Divide by two for operation cycles 20 000 Oper. 20 000 Oper. 20 000 Oper.
Fuse types, IEC 60269-2 DIN 43620 000, 00 7) 000, 00 7) 0 8)
NFC 63210, 63211 22x58 1
A2A44) A2-A44) B1-B4
BS 88-2, -6
M5/73 mm M5/73 mm M6/111 mm
distance of fuse-link bolts
M8/94 mm M8/94 mm
Terminal tightening torque 15-22 Nm 15-22 Nm M8:15-22 Nm 3),
Counter torque required
M10:30-44 Nm
Fuse-links bolts tightening torque M5:3.5 Nm M8:5 M5:3 Nm M8:5 Nm 4 Nm
Nm 5 Nm
Operating torque Typical for 3 and 4-pole switches 7 Nm 7 Nm 7 Nm
*
= Utilization category B.
1)
Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5ºC. Category B: -5ºC...-35ºC.
2)
Some fuse links limit these figures further. Starting current charasteristics must be considered separately.
3)
Side terminals tightening torque max 15 Nm.
4)
Max fuse body diam. 32 mm.
5)
BS fuse manufacturers covered by this table ABB, MEM, Bussmann, GEC.
6)
3-pole types only.
7)
Max. allowed fuse-link knife height is 15 mm.
8)
Max. allowed fuse-link knife height is 21 mm.
17 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses, IEC
Technical data for OS250...400

Technical data according to IEC 60947-3

Switch type OS_250 OS_315 OS_400


Rated insulation voltage and
Pollution degree 3
rated operational voltage AC-20 and DC-20 50 Hz 1min. 1000 V 1000 V 1000 V
Dielectric strength 10 kV 10 kV 10 kV
Rated impulse withstand voltage 12 kV 12 kV 12 kV
Rated thermal current in ambient 35 °C 250 A/23 W 315 A/32 W 400 A/45 W
and temporarily 40 °C1) / max. fuse power dissipation
...with minimum cable cross section 120 mm2 185 mm2 240 mm2
Derating, mounting on In open air or ventilated enclosure 0% 0% 0%
wall horizontal fuses Totally enclosed 5% 5% 5%
Derating, mounting on ceiling 10 % 10 % 10 %
Derating at 60 °C In open air / in enclosure 20/20 % 20/20 % 20/20 %
Power loss / pole With rated current, without fuse BB 13 W 19 W 30 W
LR 17 W 25 W 40 W
Rated operational current AC-21A, AC-22A and AC-23A Up to 690V 215 A 315 A 400 A
Rated operational current /poles in series 48V 250 A/1 315 A/2 400 A/2
DC-21A, DC-22A and DC-23A 110-220V 250 A/1 315 A/2 400 A/2
440V 250 A/2 315 A/3* 400 A/3
660V 250 A/3 315 A/4* 400 A/4*
750V 230 A/4 315 A/4* 400 A/4*
880V 230 A/4
Rated operational power AC-232) The kW-ratings are accurate for 230 V 75 kW 100 kW 110 kW
three-phase 1500 R.P.M standard 400 V/415 V 132/140 kW 170/180 kW 220/230 kW
asynchronous motors. 500 V/690 V 170/240 kW 220/295 kW 280/335 kW
Rated breaking capacity in category AC-23 up to 690 V 2000 A 3200 A 3200 A
Rated conditional short-circuit current Ip (r.m.s.) at prospective SC-current 65 kA, 500V 32,5 kA 40,5 kA
and corresponding max. allowed cut-off current îc Max OFA_ fuse size gG/aM 250/- A 400/- A
The cut-off current îc refers to values listed by at prospective SC-current 100 kA, 500 V 37,5 kA 63,5 kA
fuse manufacturers6) Max OFA_ fuse size gG/aM 250/250 A 7) 500/500 A 7) 8)
(single phase test acc. to IEC60269) at prospective SC-current 50 kA, 690 V 29,5 kA 32 kA
Max OFA_ fuse size gG/aM 250/- A 355/- A
at prospective SC-current 80 kA, 690 V 32,5 kA 38 kA
Max OFA_ fuse size gG/aM 200/250 A 7) 355/400 A 7)
at prospective SC-current 50 kA, 415 V 26 kA 28 kA 34 kA
Max BS fuse size gG/gM 250/- A 315/- A 400/- A
at prospective SC-current 80 kA, 415 V 30 kA 50 kA 50 kA
Max BS fuse size gG/gM 250/200M250 A 7) 400/400M500 A 7) 400/400M500 A 7)
at prospective SC-current 50 kA, 690 V 28 kA 30 kA 38 kA
Max BS fuse size gG/gM 250/- A 315/- A 400/- A
at prospective SC-current 80 kA, 690 V 28 kA 48 kA 48 kA
Max BS fuse size gG/gM 250/200M250 A 7) 400/400M450 A 7) 400/400M450 A 7)
Rated short-time withstand current, 1s. r.m.s. -value 8 kA 14 kA 14 kA
Max. distance from switch frame 150 mm 150 mm 150 mm
to nearest busbar/cable support
Rated capacitor power The capacitor ratings of the switch-fuses 400 V/415 V
when no initial charge of the capacitor are limited by the fuse links 690 V
Mechanical endurance Divide by two for operation cycles 20 000 Oper. 16 000 Oper. 16 000 Oper.
Fuse types, IEC 60269-2 DIN 43620 0-1 9) 0-2 10)
NFC 0-3 Ref.A, 4a Ref.B 1 2
BS 88-2, -6 B1-B33) B1-B44) B1-B44)
Size / distance of fuse-link bolts M8/111 mm M8/111 mm M8/111 mm
Terminal tightening torque Counter torque required M8:15-22 Nm 5), M8:15-22 Nm 5), M8:15-22 Nm 5),
M10:30-44 Nm M10:30-44 Nm M10:30-44 Nm
Fuse-links bolts tightening torque BB 5 Nm 20 Nm 20 Nm
LR 5 Nm 20 Nm 20 Nm
Operating torque Typical for 3 and 4-pole switch 7 Nm 19 Nm 19 Nm
*
= Utilization category B.
1)
Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5ºC. Category B: -5ºC...-35ºC.
2)
Some fuse links limit these figures further. Starting current charasteristics must be considered separately.
3)
Max fuse body diam 52 mm.
4)
Max fuse body diam 62 mm.
5)
Side terminals tightening torque max 15 Nm.
6)
BS fuse manufacturers covered by this table ABB, MEM, Bussmann, GEC.
7)
3-poles type only.
8)
Plug in types: fuse size gG/aM: 400/400.
9)
Max. allowed fuse-link knife height is 21 mm.
10)
Max. allowed fuse-link knife height is 27 mm.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 18


Motorized switch fuses, IEC
Technical data for motor operators OSM32...250

Technical data for motor operators OSM according to IEC 60947

Switch type 32…63 100…160 200…250


Rated operational voltage Ue Pollution degree 3 50/60 Hz 220 - 240 V AC 220 - 240 V AC
Operating voltage range 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue
Operating time1) 90° I - 0, 0 - I 220-240VAC 0.5 - 1.0 s 0.5 - 1.0 s 0.5 - 1.0 s
Nominal current In1) 220-240VAC 0.3 A 0.3 A 0.3 A

03
Current Inrush1) 220-240VAC 1.5 A 1.5 A 1.5 A
Overload fuse Type / In / Capacity 220-240VAC T / 315 mA / H T / 315 mA / H T / 315 mA / H
Size 5x20 mm 5x20 mm 5x20 mm
Operating rate Cycle 0-I-0
Max. continuous 220-240VAC 1 cycles / min 1 cycles / min 1 cycles / min
Max. short-time ≤ 10 cycles 220-240VAC 10 cycles / min 10 cycles / min 10 cycles / min
Overvoltage category III III III
Rated impulse withstand voltage Uimp 4 kV 4 kV 4 kV
Dielectric strength 50 Hz 1 min. 1.5 kV 1.5 kV 1.5 kV
Impulse command Min. impulse
duration 100 ms 100 ms
Terminals Voltage supply wiring for Ue PE - N -L PE - N -L PE - N -L
Cross section solid/stranded 1.5 - 2.5 mm2 1.5 - 2.5 mm2 1.5 - 2.5 mm2
Short-circuit protection device max.fuse size 16 A 16 A 16 A
Push-button control C-I-O no SELV no SELV no SELV
Cross section solid/stranded 1.5 - 2.5 mm2 1.5 - 2.5 mm2 1.5 - 2.5 mm2
Maximum cable length 100 m 100 m 100 m
State information of locking no SELV no SELV no SELV
Handle attached or motor opertor locked 11-12-14 (C/O) 5A/250V cosφ=1 5A/250V cosφ=1 5A/250V cosφ=1
Locking motor operator 23-24 (NO) 5A/250V cosφ=1 5A/250V cosφ=1 5A/250V cosφ=1
Short-circuit protection device MCB type and size C/2A C/2A C/2A
Protection degree IP20 IP20 IP20
Operating temperature -25…+55 °C -25…+55 °C -25…+55 °C
Transportation and storage temperature -40…+70 °C -40…+70 °C -40…+70 °C
Max. altitude 2000 m 2000 m 2000 m
1)
Under nominal conditions.
19 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motorized switch fuses, IEC
Technical data for motor operators OSM315...1250

Technical data for motor operators OSM according to IEC 60947

Switch type 315...400 630…800 1250


Rated operational voltage Ue Pollution degree 3 50/60 Hz 220 - 240 V AC 220 - 240 V AC 220 - 240 V AC
Operating voltage range 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue
Operating time1) 90° I - 0, 0 - I 220-240VAC 0.5 - 1.2 s 0.5 - 1.5 s 0.8 - 2.0 s
Nominal current In1) 220-240VAC 0.5 A 0.9 A 1.4 A
Current Inrush1) 220-240VAC 2.5 A 4A 10 A
Overload fuse Type / In / Capacity 220-240VAC T / 500 mA/ H T / 1000 mA/ H T / 2000 mA/ H
Size 5x20 mm 5x20 mm 5x20 mm
Operating rate Cycle 0 - I - 0
Max. continuous 220-240VAC 1 cycles / min 1 cycles / min 0.5 cycles / min
Max. short-time ≤ 10 cycles 220-240VAC 10 cycles / min 10 cycles / min 5 cycles / min
Overvoltage category III III
Rated impulse withstand voltage Uimp 4 kV 4 kV
Dielectric strength 50 Hz 1 min. 1.5 kV 1.5 kV
Impulse command Min. impulse
duration 100 ms 100 ms
Terminals Voltage supply wiring for Ue PE - N - L PE - N - L
Cross section solid/stranded 1.5 - 2.5 mm2 1.5 - 2.5 mm2 1.5 - 2.5 mm2
Short-circuit protection device max.fuse size 16 A 16 A 16 A
Push-button control C- I-O no SELV no SELV no SELV
Maximum cable length 100 m 100 m 100 m
State information of locking no SELV no SELV no SELV
Handle attached or motor operator locked 11-12-14 (C/O) 5A/250V cosφ=1 5A/250V cosφ=1 5A/250V cosφ=1
Locking motor operator 23-24 (NO) 5A/250V cosφ=1 5A/250V cosφ=1 5A/250V cosφ=1
Short-circuit protection device MCB type and size C/2A C/2A C/2A
Protection degree IP20 IP20 IP20
Operating temperature -25…+55 °C -25…+55 °C -25…+55 °C
Transportation and storage temperature -40…+70 °C -40…+70 °C -40…+70 °C
Max. altitude 2000 m 2000 m 2000 m
1)
Under nominal conditions.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 20


Fusible disconnect switches, UL/CSA
Technical data for OS30...200

OS Mini 30 OS_60G OS_100G OS_200


Approvals*) - UL98, IEC 2 pole UL98, IEC 2 pole UL98, IEC 2 pole
UL98, IEC 3 pole UL98, IEC 3 pole UL98, IEC 3 pole UL98, IEC 3 pole
UL98, IEC 4 pole UL98, IEC 4 pole UL98, IEC 4 pole UL98, IEC 4 pole

03
Technical data according to UL/CSA
General purpose amp rating pf= 0.7...0.8 up to 40ºC 30 A 60 A 100 A 200 A
Max. operating voltage 600 VAC 600 VAC 600 VAC 600 VAC
250 VDC 250 VDC 250 VDC
Max. horsepower rating/ motor FLA current pf= 0.4...0.5 Three phase 240 V 7.5 HP/22.0 A 15 HP/42.0 A 30 HP/80.0 A 60 HP/154.0 A
480 V 15 HP/21.0 A 30 HP/40.0 A 60 HP/77.0 A 125 HP/156.0 A
600 V 20 HP/22.0 A 50 HP/52.0 A 75 HP/77.0 A 150 HP/144.0 A
Single phase 120 V 2 HP/24.0 A
240 V 3 HP/17.0 A
Short circuit rating with fuse, 3 and 4-pole types UL/CSA fuse size 200 kA 200 kA 200 kA 200 kA
UL/CSA fuse type 30 A 60 A 100 A 200 A
J/CC J J J
Min. electrical endurance pf= 0.75...0.8 operation cycles 6 000 6 000 6 000 6 000
Terminal lug kits Integral Integral OZXA-24 OZXA-200
Wire range #18-8 AWG #14-4 AWG #14-2/0 AWG #4-300 MCM
Torque Wire tightening 17 Ib.in 30/35 Ib.in 3) 120 Ib.in 200 Ib.in
Lug mounting N/A N/A 50 Ib.in 72 Ib.in

Technical data according to IEC 60947-3


Rated insulation voltage Pollution degree 3 50 Hz 1min. 1 000 V 1 000 V 1 000 V 1 000 V
Dielectric strength 10 kV 10 kV 10 kV 10 kV
Rated impulse withstand voltage 12 kV 12 kV
Rated thermal current in ambient 40 °C / In open air 32 A/3.5 W 63 A/7.5 W 160 A/12 W 200 A/17 W
max. fuse power dissipation1) In enclosure 32 A/33.5 W 63 A/7.5 W 160 A/10,135 A/12 W 200 A/15 W
...with minimum cable cross section Cu 6 mm2 16 mm2 70 mm2 95 mm2
Derating, mounting on In open air or ventilated enclosure 0% 0% 0% 0%
wall horizontal fuses Totally enclosed 5% 5% 5% 5%
Derating, mounting on ceiling 10 % 10 % 10 % 10 %
Derating at 60 °C In open air / in enclosure 20/20 % 20/20 % 20/20 % 20/20 %
Power loss / pole With rated current, without fuse 2W 4W 9W 8W
Rated operational current AC-23A Up to 500 V 32 A 63 A 160 A 200 A
690 V 32 A 63 A 160 A 200 A
Rated operational power AC-232) The kW-ratings are accurate for 230 V 7.5 kW 18.5 kW 45 kW 60 kW
three-phase 1500 R.P.M stand- 400 V 15 kW 30 kW 75 kW 110 kW
ard asynchronous motors. 415 V 15 kW 30 kW 75 kW 110 kW
500 V 18.5 kW 37 kW 90 kW 132 kW
690 V 22 kW 55 kW 132 kW 200 kW
Rated breaking capacity in category AC-23 up to 500 V 256 A 504 A 1280 A 1600 A
690 V 256 A 504 A 1280 A 1600 A
Rated short-time withstand current, 1s. r.m.s. -value 1 kA 2.5 kA 5 kA 8 kA
Built-in terminal size Cu 0.75...10 mm2 2.5...25 mm2
Fuse-links bolts tightening torque 4 Nm 4 Nm
*)
UL listed disconnects are also listed under CSA requirements.
1)
Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5ºC. Category B: -5ºC...-35ºC.
2)
Some fuse links limit these figures further. Starting current charasteristics must be considered separately.
3)
30 lb.in with cable size #14-10, 35 lb.in with cable size #8-4.tw
21 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Fusible disconnect switches, UL/CSA
Technical data for OS400...1200

OS400 OS600 OS800 OS1200


Approvals*) UL98, IEC 2 pole UL98, IEC 2 pole UL98, IEC 2 pole UL98, IEC 2 pole
UL98, IEC 3 pole UL98, IEC 3 pole UL98, IEC 3 pole UL98, IEC 3 pole
UL98, IEC 4 pole UL98, IEC 4 pole UL98, IEC 4 pole UL98, IEC 4 pole

Technical data according to UL/CSA


General purpose amp rating pf= 0.7...0.8 up to 40ºC 400 A 600 A 800 A 1200 A
Max. operating voltage 600 VAC 600 VAC 600 VAC 600 VAC
250 VDC 250 VDC 250 VDC 250 VDC
Max. horsepower rating/ motor FLA current 240 V 125.0 HP/312.0 A 200 HP/480.0 A 250 HP/602.0 A
pf= 0.4...0.5 Three phase 480 V 250.0 HP/302.0 A 400 HP/477.0 A 500 HP/590.0 A
600 V 350.0 HP/336.0 A 500 HP/472.0 A 500 HP/472.0 A
120 V
Single phase
240 V
Short circuit rating with fuse, 3 and 4-pole types UL/CSA fuse size 200 kA 200 kA 200 kA 200 kA
400 A 600 A 800 A 1200 A
UL/CSA fuse type
J J L L
Min. electrical endurance pf= 0.75...0.8 operation cycles 1000 1000 500 500
Terminal lug kits OZXA-400 OZXA-800 OZXA-800 OZXA-1200
Wire range #2-600MCM (2)#2-600MCM (2)#2-600MCM (4)#2-600MCM
Torque Wire tightening 375 Ib.in 500 Ib.in 500 Ib.in 500 Ib.in
Lug mounting 240 Ib.in 480 Ib.in 480 Ib.in 480 Ib.in

Technical data according to IEC 60947-3


Rated insulation voltage Pollution degree 3 50 Hz 1min. 1 000 V 1 000 V 1 000 V 1 000 V
Dielectric strength 10 kV 10 kV 10 kV 10 kV
Rated impulse withstand voltage 12 kV 12 kV 12 kV 12 kV
Rated thermal current in ambient 40 °C / In open air 400 A/45 W 630 A/60 W 800 A/65 W 1250 A/110 W
max. fuse power dissipation1) In enclosure 400 A/30 W 570 A/50 W 720 A/55 W 1000 A/85 W
...with minimum cable cross section Cu 240 mm2 2x185 mm2 2x240 mm2 2x400 mm2
Derating, mounting on In open air or ventilated enclosure 0% 0% 4% 4%
wall horizontal fuses Totally enclosed 5% 5% 8% 8%
Derating, mounting on ceiling 10 % 10 % 10 % 10 %
Derating at 60 °C In open air / in enclosure 20/20 % 20/20 % 20/20 % 20/20 %
Power loss / pole With rated current, without fuse 30 W 46 W 75 W 75 W
Rated operational current AC-23A Up to 500 V 400 A 630 A 800 A 1000 A 3)
690 V 400 A 630 A 800 A 1000 A 3)
Rated operational power AC-23 2)
The kW-ratings are accurate for 230 V 132 kW 200 kW 250 kW 315 kW 3)
three-phase 1500 R.P.M standard 400 V 220 kW 355 kW 450 kW 560 kW 3)
asynchronous motors. 415 V 230 kW 355 kW 450 kW 560 kW 3)
500 V 280 kW 450 kW 560 kW 710 kW 3)
690 V 400 kW 630 kW 710 kW 1000 kW 3)
Rated breaking capacity in category AC-23 up to 500 V 3200 A 6400 A 6400 A 8000 A
690 V 3200 A 6400 A 6400 A 8000 A
Rated short-time withstand current, 1s. r.m.s. -value 14 kA 20 kA 20 kA
Built-in terminal size Cu
Fuse-links bolts tightening torque 20 Nm 40 Nm 40 Nm 40 Nm
*)
UL listed disconnects are also listed under CSA requirements.
1)
Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5ºC. Category B: -5ºC...-35ºC.
2)
Some fuse links limit these figures further. Starting current charasteristics must be considered separately.
3)
Utilization category B.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 22

03
23 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 24


Switch fuses
Ordering information
Ordering information for Switch fuses DIN type
Manual operated switch fuses, 32…40 A 25
Manual operated switch fuses, 63 A 26
Manual operated switch fuses, 125 A 27
Manual operated switch fuses, 160 A 28
Manual operated switch fuses, 200 A 29
Manual operated switch fuses, 250 A 30
Manual operated switch fuses, 400 A 31
Manual operated switch fuses, 630 A 32
Manual operated switch fuses, 800 A 33

04
Manual operated switch fuses, 1250 A 34
Special connected switch fuses, 125…160 A 35
Special connected switch fuses, 200…400 A 36
Motorized switch fuses, 32...1250 A 37

Ordering information for Switch fuses BS type


Manual operated switch fuses, 20…32 A 38
Manual operated switch fuses, 63 A 39
Manual operated switch fuses, 100 A 40
Manual operated switch fuses, 125 A 41
Manual operated switch fuses, 160 A 42
Manual operated switch fuses, 200 A Gamma range 43
Manual operated switch fuses, 100…200 A with integrated nuts 44
Manual operated switch fuses, 200 A 45
Manual operated switch fuses, 250 A 46
Manual operated switch fuses, 315 A 47
Manual operated switch fuses, 400 A 48
Manual operated switch fuses, 630 A 49
Manual operated switch fuses, 800 A 50
Manual operated switch fuses, 1250 A 51
Special connected switch fuses, 125…200 A 52
Special connected switch fuses, 250…400 A 53
Motorized switch fuses, 32...1250 A 54

Ordering information for Switch fuses NFC type


Manual operated switch fuses, NFC type, 25…50 A 55
Manual operated switch fuses, NFC type, 125 A 56

Ordering information for Fusible disconnect switches, UL/CSA



Fusible disconnect switches, CC and J types, 30A 57
Fusible discconnect switches, J type, 60 A 58
Fusible disconnect switches, J type, 100 A 59
Fusible disconnect switches, J type, 200 A 60
Fusible disconnect switches, J type, 400 A 61
Fusible disconnect switches, J type, 600 A 62
Fusible disconnect switches, L type, 800…1200 A 63

Selection overview 65-67

Ordering information for accessories 69-96


25 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for DIN-type, 32...40 A


Manual operated switch fuses, DIN-type, 32…40 A
Protected tunnel terminals, IP20. Mechanism located between the poles. The handles are
IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position.
OS32...63GD02P

G = Gamma range switch fuses from 32 to 160 Amperes


F = OS Mini range switch fuses 40 Amperes

N2 = Non-fused switched neutral on the right side


F = Fused switched neutral
OS32...63GD04N2P

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
32 000 2 OS32GD02 1SCA116776R1001
32 000 3 OS32GD03 1SCA115188R1001
OS32...63GD03K
32 000 4 OS32GD04N2 1SCA115192R1001
32 000 4 OS32GD04F 1SCA115195R1001
40 000 3 OS40FD12000-2 1SCA108921R1001
40 000 4 OS40FD22000N1-2 1SCA108940R1001
With 161 mm shaft and external handle OHB45J6
32 000 2 OS32GD02P 1SCA116714R1001
32 000 3 OS32GD03P 1SCA115189R1001
OS32...63GD04N2K 32 000 4 OS32GD04N2P 1SCA115193R1001
32 000 4 OS32GD04FP 1SCA115196R1001
With 150 mm shaft and external handle OHB65J6
40 000 3 OS40FD12000 1SCA108914R1001
40 000 4 OS40FD22000N1 1SCA108938R1001
With direct mount handle OSV200BK
32 000 2 OS32GD02K 1SCA122905R1001
32 000 3 OS32GD03K 1SCA116733R1001
OS32...63GDS30K 32 000 4 OS32GD04N2K 1SCA116734R1001
32 000 4 OS32GD04FK 1SCA116737R1001

Side operated
Shaft and handle not included
32 000 3 OS32GDS30 1SCA115963R1001
32 000 4 OS32GDS40N2 1SCA116046R1001

OS32...63GDS40N2K 32 000 4 OS32GDS40F 1SCA116755R1001


40 000 3 OS40FDS30000-2 1SCA108945R1001
With 70 mm shaft and external handle OHB65J6
40 000 3 OS40FDS30000 1SCA108942R1001
40 000 4 OS40FDS40000N1 1SCA108954R1001
With direct mount handle OHB65D6
32 000 3 OS32GDS30K 1SCA115929R1001
32 000 4 OS32GDS40N2K 1SCA116402R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 26


Manual operated switch fuses, IEC
Ordering information for DIN-type, 63 A


Manual operated switch fuses, DIN-type, 63 A
Protected tunnel terminals, IP20. Mechanism located between the poles. The handles are IP65
protected, padlockable in the OFF-position and with door interlock in the ON-position.

OS32...63GD02P
G = Gamma range switch fuses from 32 to 160 Amperes

N2 = Non-fused switched neutral on the right side


F = Fused switched neutral

OS32...63GD04N2P Front operated

04
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
63 000 2 OS63GD02 1SCA116777R1001
63 000 3 OS63GD03 1SCA115206R1001
63 000 4 OS63GD04N2 1SCA115208R1001
63 000 4 OS63GD04F 1SCA115225R1001
OS32...63GD03K
With 161 mm shaft and external handle OHB45J6
63 000 2 OS63GD02P 1SCA116715R1001
63 000 3 OS63GD03P 1SCA115207R1001
63 000 4 OS63GD04N2P 1SCA115209R1001
63 000 4 OS63GD04FP 1SCA115228R1001
With direct mount handle OSV200BK
63 000 2 OS63GD02K 1SCA122906R1001
63 000 3 OS63GD03K 1SCA116738R1001
OS32...63GD04N2K
63 000 4 OS63GD04N2K 1SCA116876R1001
63 000 4 OS63GD04FK 1SCA116739R1001

Side operated
Shaft and handle not included
63 000 3 OS63GDS30 1SCA116007R1001
63 000 4 OS63GDS40N2 1SCA116047R1001
63 000 4 OS63GDS40F 1SCA116877R1001
OS32...63GDS30K
With direct mount handle OHB65D6
63 000 3 OS63GDS30K 1SCA115931R1001
63 000 4 OS63GDS40N2K 1SCA116403R1001

OS32...63GDS40N2K
27 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for DIN-type, 125 A


Manual operated switch fuses, DIN-type, 125 A
Including terminal bolt set M8X25. The handles are IP65 protected, padlockable in the OFF-
position and with door interlock in the ON-position.
OS125...160GD03P
G = Gamma range switch fuses from 32 to 160 Amperes

F = Fused switches neutral


N2 = Non-fused switched neutral on the right side

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
OS125...160GD03K
Shaft and handle not included
125 000, 00 2 OS125GD02 1SCA116873R1001
125 000, 00 3 OS125GD03 1SCA115638R1001
125 000, 00 4 OS125GD04N2 1SCA115876R1001
125 000, 00 4 OS125GD04F 1SCA115685R1001
With 161 mm shaft and external handle OHB45J6
125 000, 00 2 OS125GD02P 1SCA116716R1001
125 000, 00 3 OS125GD03P 1SCA115639R1001
OS125...160GD04FK
125 000, 00 4 OS125GD04N2P 1SCA115877R1001
125 000, 00 4 OS125GD04FP 1SCA115686R1001
With direct mount handle OSV200BK
125 000, 00 2 OS125GD02K 1SCA122908R1001
125 000, 00 3 OS125GD03K 1SCA116878R1001
125 000, 00 4 OS125GD04N2K 1SCA116740R1001
125 000, 00 4 OS125GD04FK 1SCA116741R1001

OS125...160GDS40N2K
Side operated
Shaft and handle not included
125 000, 00 3 OS125GDS30 1SCA115966R1001
125 000, 00 4 OS125GDS40N2 1SCA115967R1001
125 000, 00 4 OS125GDS40F 1SCA116756R1001
With direct mount handle OHB65D6
125 000, 00 3 OS125GDS30K 1SCA115933R1001
125 000, 00 4 OS125GDS40N2K 1SCA115934R1001


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM100G...160G Long type 3 OSS160GG1L/3 1SCA114764R1001
OS/OSM100G...160G Short type 3 OSS160GG1S/3 1SCA114766R1001
OS/OSM100G...160G Long type 4 OSS160GG1L/4 1SCA114765R1001
OS/OSM100G...160G Short type 4 OSS160GG1S/4 1SCA114767R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 28


Manual operated switch fuses, IEC
Ordering information for DIN-type, 160 A


Manual operated switch fuses, DIN-type, 160 A
Protected tunnel terminals, IP20. Mechanism located between the poles. The handles are IP65
protected, padlockable in the OFF-position and with door interlock in the ON-position.

OS125...160GD03P
G = Gamma range switch fuses from 32 to 160 Amperes

N2 = Non-fused switched neutral on the right side


F = Fused switched neutral

Front operated
Number

04
Rated current [A] Fuse size of poles Type Order number
OS125...160GD03K
Shaft and handle not included
160A 000, 00 2 OS160GD02 1SCA116778R1001
160A 000, 00 3 OS160GD03 1SCA114221R1001
160A 000, 00 4 OS160GD04N2 1SCA115881R1001
160A 000, 00 4 OS160GD04F 1SCA115401R1001
With 161 mm shaft and external handle OHB45J6
160A 000, 00 2 OS160GD02P 1SCA116717R1001
OS125...160GD04FK 160A 000, 00 3 OS160GD03P 1SCA115399R1001
160A 000, 00 4 OS160GD04N2P 1SCA115882R1001
160A 000, 00 4 OS160GD04FP 1SCA115402R1001
With direct mount handle OSV200BK
160A 000, 00 2 OS160GD02K 1SCA122910R1001
160A 000, 00 3 OS160GD03K 1SCA116742R1001
160A 000, 00 4 OS160GD04N2K 1SCA116743R1001
160A 000, 00 4 OS160GD04FK 1SCA116880R1001

OS125...160GDS40N2K
Side operated
Shaft and handle not included
160A 000, 00 3 OS160GDS30 1SCA115968R1001
160A 000, 00 4 OS160GDS40N2 1SCA115969R1001
160A 000, 00 4 OS160GDS40F 1SCA116757R1001
With direct mount handle OHB65D6
160A 000, 00 3 OS160GDS30K 1SCA115935R1001
160A 000, 00 4 OS160GDS40N2K 1SCA115939R1001


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM100G...160G Long type 3 OSS160GG1L/3 1SCA114764R1001
OS/OSM100G...160G Short type 3 OSS160GG1S/3 1SCA114766R1001
OS/OSM100G...160G Long type 4 OSS160GG1L/4 1SCA114765R1001
OS/OSM100G...160G Short type 4 OSS160GG1S/4 1SCA114767R1001
29 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for DIN-type, 200 A


Manual operated switch fuses, DIN-type, 200 A

Including terminal bolt set M8X25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
OS200DZ04N2P position.

F = Fuse switched neutral


N2 = Non-fused switched neutral on the right side

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
OS200...250D03N3P 200 0 2 OS200D02 1SCA022759R9140
200 0 3 OS200D03 1SCA022715R2240
200 00 3 OS200DZ03 1SCA022797R3520
200 0 4 OS200D04N2 1SCA022717R3670
200 0 4 OS200D04F 1SCA022725R8230
200 00 4 OS200DZ04N2 1SCA022819R4110
With 161 mm shaft and external handle OHB45J6
200 0 2 OS200D02P 1SCA022759R9220
200 0 3 OS200D03P 1SCA022709R9500
OS200...250D02P
200 00 3 OS200DZ03P 1SCA022797R3440
200 0 4 OS200D04N2P 1SCA022709R9680
200 0 4 OS200D04FP 1SCA022725R4750
200 00 4 OS200DZ04N2P 1SCA022820R9230
With direct mount handle OSV200BK
200 0 3 OS200D03K 1SCA022764R7130
200 0 4 OS200D04N2K 1SCA022768R7430
OS200...250D03K 200 0 4 OS200D04FK 1SCA022783R1220

Side operated
Shaft and handle not included
200 0 3 OS200DS30 1SCA022871R1370
200 0 4 OS200DS40N2 1SCA022871R1700
200 0 4 OS200DS40F 1SCA022871R1530
OS200...250DS40FK
With direct mount handle OHB65D6
200 0 3 OS200DS30K 1SCA022871R1450
200 0 4 OS200DS40N2K 1SCA022871R1880
200 0 4 OS200DS40FK 1SCA022871R1610

OSS200G1L —
Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

OSS200G1S Number
Suitable for switches Description of poles Type Order number
OS/OSM200 Long type 3 OSS200G1L/3 1SCA022731R8910
OS/OSM200 Short type 3 OSS200G1S/3 1SCA022732R0130
OS/OSM200 Long type 4 OSS200G1L/4 1SCA022731R9040
OS/OSM200 Short type 4 OSS200G1S/4 1SCA022732R0050
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 30


Manual operated switch fuses, IEC
Ordering information for DIN-type, 250 A


Manual operated switch fuses, DIN-type, 250 A
Including terminal bolt set M10X30. The handles are IP65 protected, padlockable in the OFF-
position and with door interlock in the ON-position.

F = Fused switched neutral


OS200...250D03N3P
N2 = Non-fused switched neutral on the right side

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included

04
250 0-1 2 OS250D02 1SCA022746R7740
250 0-1 3 OS250D03 1SCA022720R7080
OS200...250D02P
250 0-1 4 OS250D04N2 1SCA022725R0500
250 0-1 4 OS250D04F 1SCA022727R0360
With 161 mm shaft and external handle OHB45J6
250 0-1 2 OS250D02P 1SCA022760R0170
250 0-1 3 OS250D03P 1SCA022719R0090
250 0-1 4 OS250D04N2P 1SCA022719R2380
250 0-1 4 OS250D04FP 1SCA022726R8620
OS200...250D03K
With direct mount handle OSV200BK
250 0-1 2 OS250D02K 1SCA101367R1001
250 0-1 3 OS250D03K 1SCA022763R6360
250 0-1 4 OS250D04N2K 1SCA022763R6440
250 0-1 4 OS250D04FK 1SCA022783R1310

OS200...250DS40FK Side operated


Shaft and handle not included
250 0-1 3 OS250DS30 1SCA022871R2180
250 0-1 4 OS250DS40N2 1SCA022871R2510
250 0-1 4 OS250DS40F 1SCA022871R2340
With direct mount handle OHB65D6
250 0-1 3 OS250DS30K 1SCA022871R2260
OSS250G1L 250 0-1 4 OS250DS40N2K 1SCA022871R2690
250 0-1 4 OS250DS40FK 1SCA022871R2420


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM250 Long type 3 OSS250G1L/3 1SCA022731R9390
OS/OSM250 Short type 3 OSS250G1S/3 1SCA022731R9550
OS/OSM250 Long type 4 OSS250G1L/4 1SCA022731R9470
OS/OSM250 Short type 4 OSS250G1S/4 1SCA022731R9630
31 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for DIN-type, 400 A


Manual operated switch fuses, DIN-type, 400 A
Including terminal bolt set M10X30. The handles are IP65 protected, padlockable in the OFF-
position and with door interlock in the ON-position.

F = Fused switched neutral


OS400D04FP N2 = Non-fused switched neutral on the right side

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
400 0…2 2 OS400D02 1SCA022811R2820
400 0…2 3 OS400D03 1SCA022753R1000
400 0…2 4 OS400D04N2 1SCA022754R2620
OS400D03K 400 0…2 4 OS400D04F 1SCA022754R3860
With 250 mm shaft and external handle OHB95J12
400 0…2 2 OS400D02P 1SCA022811R2740
400 0…2 3 OS400D03P 1SCA022719R0250
400 0…2 4 OS400D04N2P 1SCA022719R2460
400 0…2 4 OS400D04FP 1SCA022753R7110
With direct mount handle OSV400DK
400 0…2 2 OS400D02K 1SCA101369R1001
OS400DS40FK
400 0…2 3 OS400D03K 1SCA022779R5410
400 0…2 4 OS400D04N2K 1SCA022763R7250
400 0…2 4 OS400D04FK 1SCA022783R1490

Side operated
Shaft and handle not included
400 0…2 3 OS400DS30 1SCA022871R2850
400 0…2 4 OS400DS40N2 1SCA022871R3230
400 0…2 4 OS400DS40F 1SCA022871R3070
With direct mount handle OHB145D12
400 0…2 3 OS400DS30K 1SCA022871R2930
400 0…2 4 OS400DS40N2K 1SCA022871R3310
400 0…2 4 OS400DS40FK 1SCA022871R3150


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM315...400 Long type 3 OSS400G1L/3 1SCA022776R6650
OS/OSM315...400 Short type 3 OSS400G1S/3 1SCA022776R6900
OS/OSM315...400 Long type 4 OSS400G1L/4 1SCA022776R6730
OS/OSM315...400 Short type 4 OSS400G1S/4 1SCA022776R7030
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 32


Manual operated switch fuses, IEC
Ordering information for DIN-type, 630 A


Manual operated switch fuses, DIN-type, 630 A
Including terminal bolt set M12X40. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.
OS630...800D02P
F = Fused switched neutral
N2 = Non-fused switched neutral on the right side

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included

04
630 3 2 OS630D02 1SCA106144R1001
OS630...800D04FP
630 3 3 OS630D03 1SCA022825R2670
630 3 4 OS630D04N2 1SCA022825R4110
630 3 4 OS630D04F 1SCA022825R4530
With 280 mm shaft and external handle OHB145J12
630 3 2 OS630D02P 1SCA107745R1001
630 3 3 OS630D03P 1SCA022825R2830
630 3 4 OS630D04N2P 1SCA022825R4290
630 3 4 OS630D04FP 1SCA022825R4610

OS630...800D03K With direct mount handle OSV800DK


630 3 3 OS630D03K 1SCA108704R1001
630 3 4 OS630D04N2K 1SCA108705R1001
630 3 4 OS630D04FK 1SCA110300R1001

Side operated
Shaft and handle not included
630 3 3 OS630DS30 1SCA108135R1001
OS630...800DS04FK 630 3 4 OS630DS40N2 1SCA108139R1001
630 3 4 OS630DS40F 1SCA108137R1001
With direct mount handle OHB145D12
630 3 3 OS630DS30K 1SCA108136R1001
630 3 4 OS630DS40N2K 1SCA108140R1001
630 3 4 OS630DS40FK 1SCA108138R1001
OSS800G1L


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
OSS800G1S For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM600...800 Long type 3 OSS800G1L/3 1SCA022776R7200
OS/OSM600...800 Short type 3 OSS800G1S/3 1SCA022776R7540
OS/OSM600...800 Long type 4 OSS800G1L/4 1SCA022776R7380
OS/OSM600...800 Short type 4 OSS800G1S/4 1SCA022776R7460
33 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for DIN-type, 800 A


Manual operated switch fuses, DIN-type, 800 A
Including terminal bolt set M12X40. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.
OS630...800D02P
F = Fused switched neutral
N2 = Non-fused switched neutral on the right side

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
800 3 2 OS800D02 1SCA022837R2570
OS630...800D04FP
800 3 3 OS800D03 1SCA022825R4700
800 3 4 OS800D04N2 1SCA022825R5690
800 3 4 OS800D04F 1SCA022825R8520
With 280 mm shaft and external handle OHB145J12
800 3 2 OS800D02P 1SCA022837R2650
800 3 3 OS800D03P 1SCA022825R4880
800 3 4 OS800D04N2P 1SCA022825R5180
800 3 4 OS800D04FP 1SCA022825R5000
OS630...800D03K
With direct mount handle OSV800DK
800 3 3 OS800D03K 1SCA108725R1001
800 3 4 OS800D04N2K 1SCA108722R1001
800 3 4 OS800D04FK 1SCA110299R1001

Side operated
Shaft and handle not included
800 3 3 OS800DS30 1SCA108098R1001
OS630...800DS04FK 800 3 4 OS800DS40N2 1SCA108103R1001
800 3 4 OS800DS40F 1SCA108100R1001
With direct mount handle OHB145D12
800 3 3 OS800DS30K 1SCA108099R1001
800 3 4 OS800DS40N2K 1SCA108104R1001
800 3 4 OS800DS40FK 1SCA108101R1001

OSS800G1L


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
OSS800G1S For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM600...800 Long type 3 OSS800G1L/3 1SCA022776R7200
OS/OSM600...800 Short type 3 OSS800G1S/3 1SCA022776R7540
OS/OSM600...800 Long type 4 OSS800G1L/4 1SCA022776R7380
OS/OSM600...800 Short type 4 OSS800G1S/4 1SCA022776R7460
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 34


Manual operated switch fuses, IEC
Ordering information for DIN-type, 1250 A


Manual operated switch fuses, DIN-type, 1250 A
Including terminal bolt set M12X50. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.

OS1250D02P F = Fused switched neutral


N2 = Non-fused switched neutral on the right side

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included

04
1250 4 2 OS1250D02 1SCA114045R1001
1250 4 3 OS1250D03 1SCA105474R1001
OS1250D03P
1250 4 4 OS1250D04N2 1SCA105247R1001
1250 4 4 OS1250D04F 1SCA105472R1001
1250 4a 2 OS1250DA02 1SCA114058R1001
1250 4a 3 OS1250DA03 1SCA105165R1001
1250 4a 4 OS1250DA04N2 1SCA105242R1001
1250 4a 4 OS1250DA04F 1SCA105239R1001
With 395 mm shaft and external handle OHB274J12
1250 4 2 OS1250D02P 1SCA114051R1001
OS1250D04P
1250 4 3 OS1250D03P 1SCA105475R1001
1250 4 4 OS1250D04N2P 1SCA105248R1001
1250 4 4 OS1250D04FP 1SCA105473R1001
1250 4a 2 OS1250DA02P 1SCA114059R1001
1250 4a 3 OS1250DA03P 1SCA105238R1001
1250 4a 4 OS1250DA04N2P 1SCA105243R1001
1250 4a 4 OS1250DA04FP 1SCA105240R1001
With direct mount handle OSV1250DK
OS1250D03K 1250 4 3 OS1250D03K 1SCA108718R1001
1250 4 4 OS1250D04N2K 1SCA108719R1001
1250 4 4 OS1250D04FK 1SCA113109R1001
1250 4 3 OS1250DA03K 1SCA108720R1001
1250 4 4 OS1250DA04N2K 1SCA108721R1001


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS1200...1250 Long type 3 OSS1250G1L/3 1SCA107938R1001
OS1200...1250 Short type 3 OSS1250G1S/3 1SCA107939R1001
OS1200...1250 Long type 4 OSS1250G1L/4 1SCA107940R1001
OS1200...1250 Short type 4 OSS1250G1S/4 1SCA107940R1001
35 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses, IEC
Ordering information for DIN-type, 125 - 160 A


Special connected switch fuses, DIN-type, 125 - 160 A
Including terminal bolt set M8X25. The handles are IP65 protected, padlockable in the OFF-
position and with door interlock in the ON-position.

OS125...160GD12LRP
G = Gamma range from switch fuses from 125 to 160 Amperes

N2 = Non-fused switched neutral on the right side

Front operated with back in- back out connection


Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
OS125...160GD04BBN2
125 000, 00 3 OS125GD03BB 1SCA120801R1001
125 000, 00 4 OS125GD04BBN2 1SCA120805R1001
160A 000, 00 3 OS160GD03BB 1SCA120654R1001
160A 000, 00 4 OS160GD04BBN2 1SCA120660R1001
With 161 mm shaft and external handle OHB65J6
125 000, 00 3 OS125GD03BBP 1SCA120802R1001
125 000, 00 4 OS125GD04BBN2P 1SCA120806R1001
160A 000, 00 3 OS160GD03BBP 1SCA120655R1001
160A 000, 00 4 OS160GD04BBN2P 1SCA120661R1001

Front operated with left in-right out connection


Shaft and handle not included
125 000, 00 3 OS125GD12LR 1SCA120253R1001
125 000, 00 3 OS125GD21LR 1SCA120319R1001
125 000, 00 4 OS125GD22LR 1SCA120262R1001
160 000, 00 3 OS160GD12LR 1SCA120266R1001
160 000, 00 3 OS160GD21LR 1SCA120268R1001
160 000, 00 4 OS160GD22LR 1SCA120274R1001
With 161 mm shaft and external handle OHB65J6
125 000, 00 3 OS125GD12LRP 1SCA120062R1001
125 000, 00 3 OS125GD21LRP 1SCA120255R1001
125 000, 00 4 OS125GD22LRP 1SCA120263R1001
160 000, 00 3 OS160GD12LRP 1SCA120267R1001
160 000, 00 3 OS160GD21LRP 1SCA120294R1001
160 000, 00 4 OS160GD22LRP 1SCA120275R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 36


Special connected switch fuses, IEC
Ordering information for DIN-type, 200 - 400 A


Special connected switch fuses, DIN-type, 200 - 400 A
Including terminal bolt set M8X25 (OS200…250) or M10X30 (OS400). Mechanism located at
the end of the switch. The handles are IP65 protected, padlockable in the OFF-position and
with door interlock in the ON-position.

OS200...250D22LRP F = Fused switched neutral


N2 =Non-fused switched neutral on the right side

Front operated with back in- back out connection


Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included

04
200 0 3 OS200D03BB 1SCA102151R1001
OS250D03BB 200 0 4 OS200D04BBN2 1SCA102146R1001
250 0-1 3 OS250D03BB 1SCA102197R1001
250 0-1 4 OS250D04BBN2 1SCA102201R1001
400 0…2 3 OS400D03BB 1SCA102273R1001
400 0…2 4 OS400D04BBN2 1SCA102291R1001
With 210 mm shaft and external handle OHB65J6
200 0 3 OS200D03BBP 1SCA102150R1001
200 0 4 OS200D04BBN2P 1SCA102139R1001
OS250D04BBN2
250 0-1 3 OS250D03BBP 1SCA102190R1001
250 0-1 4 OS250D04BBN2P 1SCA102205R1001
With 250 mm shaft and external handle OHB95J12
400 0…2 3 OS400D03BBP 1SCA102260R1001
400 0…2 4 OS400D04BBN2P 1SCA102289R1001

Front operated with left in-right out connection


Shaft and handle not included
OS400D12LRP
250 0-1 3 OS250D12LR 1SCA022852R8250
250 0-1 3 OS250D21LR 1SCA022852R8330
250 0-1 4 OS250D22LR 1SCA022853R0230
400 0…2 3 OS400D12LR 1SCA022853R2010
400 0…2 4 OS400D21LR 1SCA022853R2100
400 0…2 4 OS400D22LR 1SCA022853R4060
With 210 mm shaft and external handle OHB65J6
250 0-1 3 OS250D12LRP 1SCA022852R8410
250 0-1 3 OS250D21LRP 1SCA022852R8500
250 0-1 4 OS250D22LRP 1SCA022853R0310
With 250 mm shaft and external handle OHB95J12
400 0…2 3 OS400D12LRP 1SCA022853R2280
400 0…2 4 OS400D21LRP 1SCA022853R2360
400 0…2 4 OS400D22LRP 1SCA022853R4140
37 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motorized switch fuses, IEC
Ordering information for DIN-type, OSM32...1250 A


Motorized switch fuses OSM, 32…1250
Including a handle for manual operation, bolt kit with nut and washers for all terminals
(100A…1250A), male connectors for control circuit and a handle and spare fuse storage clip.
OSM63GD3M230C
Type codes for motor voltage Ue = 220-240 VAC

G = Gamma range from switch fuses from 32 to 160 Amperes

N2 = Non-fused switched neutral on the right side


N3 = Detachable neutral link integrated into the mechanism
Switched fusible neutral available on request.
OSM160GD3M230C

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
32 000 3 OSM32GD3M230C 1SCA116664R1001
32 000 4 OSM32GD4N2M230C 1SCA118822R1001
63 000 3 OSM63GD3M230C 1SCA116660R1001
63 000 4 OSM63GD4N2M230C 1SCA118865R1001
OSM200D4N2M230C
125 000, 00 3 OSM125GD3M230C 1SCA116674R1001
125 000, 00 4 OSM125GD4N2M230C 1SCA118828R1001
160 000, 00 3 OSM160GD3M230C 1SCA116673R1001
160 000, 00 4 OSM160GD4N2M230C 1SCA118831R1001
200 0 3 OSM200D3M230C 1SCA104284R1001
200 0 3+N OSM200D3N3M230C 1SCA104282R1001
200 0 4 OSM200D4N2M230C 1SCA118836R1001
250 0-1 3 OSM250D3M230C 1SCA104295R1001
OSM400D3M230C
250 0-1 3+N OSM250D3N3M230C 1SCA104297R1001
250 0-1 4 OSM250D4N2M230C 1SCA118838R1001
400 0-2 3 OSM400D3M230C 1SCA104315R1001
400 0-2 3+N OSM400D3N3M230C 1SCA104317R1001
400 0-2 4 OSM400D4N2M230C 1SCA118842R1001
630 3 3 OSM630D3M230C 1SCA104518R1001
630 3 3+N OSM630D3N3M230C 1SCA104533R1001
630 3 4 OSM630D4N2M230C 1SCA118846R1001
OSM800D3M230C
800 3 3 OSM800D3M230C 1SCA104522R1001
800 3 3+N OSM800D3N3M230C 1SCA104534R1001
800 3 4 OSM800D4N2M230C 1SCA118847R1001
1250 4 3 OSM1250D3M230C 1SCA112549R1001
1250 4 3+N OSM1250D3N3M230C 1SCA112547R1001
1250 4 4 OSM1250D4N2M230C 1SCA118850R1001
1250 4a 3 OSM1250DA3M230C 1SCA112546R1001
1250 4a 3+N OSM1250DA3N3M230C 1SCA112544R1001
OSM1250D3M230C
1250 4a 4 OSM1250DA4N2M230C 1SCA118851R1001

Handles and bolt kits included as standard


Suitable for switches Handle+shaft kit
OSM32…63 OTV250EMK
OSM100…200 OTV250EMK
OSM250 OTV250EMK
OSM400 OTV400EMK
OSM630…800 OTV800EMK
OSM1250 OTV1000EMK
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 38


Manual operated switch fuses, IEC
Ordering information for BS-type, 20...32 A


Manual operated switch fuses, BS-type, 20…32
Protected tunnel terminals, IP20. Mechanism located at the end of the switch. The handles are
IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position.

OS32...63GB02P
F = OS Mini range switch fuses from 20 to 32 Amperes
G = Gamma range from switch fuses 32 Amperes

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral

Front operated

04
Number
OS32...63GB04N1P Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
20 A1 3 OS20FB12A1-2 1SCA108791R1001
20 A1 4 OS20FB22A1N1-2 1SCA108797R1001
32 A1 3 OS32FB12A1-2 1SCA108841R1001
32 A2 3 OS32FB12A2-2 1SCA108848R1001
32 A2 4 OS32FB22A1N1-2 1SCA108855R1001
32 A2 4 OS32FB22A2N1-2 1SCA108865R1001
OS32G...63GB03K 32 A2, A3 2 OS32GB02 1SCA116792R1001
32 A2, A3 3 OS32GB03 1SCA115255R1001
32 A2, A3 4 OS32GB04N1 1SCA115265R1001
With 150 mm shaft and external handle OHB65J6
20 A1 3 OS20FB12A1 1SCA108790R1001
20 A1 4 OS20FB22A1N1 1SCA108796R1001
32 A1 3 OS32FB12A1 1SCA108840R1001
32 A2 3 OS32FB12A2 1SCA108847R1001
OS32G...63GB04N1K 32 A2 4 OS32FB22A1N1 1SCA108853R1001
32 A2 4 OS32FB22A2N1 1SCA108863R1001
With 161 mm shaft and external handle OHB45J6
32 A2, A3 2 OS32GB02P 1SCA116721R1001
32 A2, A3 3 OS32GB03P 1SCA115259R1001
32 A2, A3 4 OS32GB04N1P 1SCA114610R1001
With direct mount handle OSV200BK
OS32GBS30K 32 A2, A3 3 OS32GB03K 1SCA116744R1001
32 A2, A3 4 OS32GB04N1K 1SCA116856R1001

Side operated
Shaft and handle not included
32 A2, A3 3 OS32GBS30 1SCA115955R1001
32 A2, A3 4 OS32GBS40N1 1SCA115956R1001

OS32GBS40N1K With direct mount handle OHB65D6


32 A2, A3 3 OS32GBS30K 1SCA115918R1001
32 A2, A3 4 OS32GBS40N1K 1SCA115923R1001
39 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for BS-type, 63 A


Manual operated switch fuses, BS-type, 63 A
Protected tunnel terminals, IP20. Mechanism located at the end of the switch. The handles are
IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position.

OS32...63GB02P G = Gamma range from switch fuses 63 Amperes

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
OS32...63GB04N1P
63 A2, A3 2 OS63GB02 1SCA116871R1001
63 A2, A3 3 OS63GB03 1SCA115234R1001
63 A2, A3 4 OS63GB04N1 1SCA115237R1001
63 A2, A3 4 OS63GB04F 1SCA116304R1001
With 161 mm shaft and external handle OHB45J6
63 A2, A3 2 OS63GB02P 1SCA116854R1001
63 A2, A3 3 OS63GB03P 1SCA115235R1001
OS32G...63GB03K
63 A2, A3 4 OS63GB04N1P 1SCA115238R1001
63 A2, A3 4 OS63GB04FP 1SCA116305R1001
With direct mount handle OSV200BK
63 A2, A3 3 OS63GB03K 1SCA116745R1001
63 A2, A3 4 OS63GB04N1K 1SCA116746R1001

Side operated

OS32G...63GB04N1K Shaft and handle not included


63 A2, A3 3 OS63GBS30 1SCA115957R1001
63 A2, A3 4 OS63GBS40N1 1SCA115978R1001
With direct mount handle OHB65D6
63 A2, A3 3 OS63GBS30K 1SCA115924R1001
63 A2, A3 4 OS63GBS40N1K 1SCA115979R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 40


Manual operated switch fuses, IEC
Ordering information for BS-type, 100 A


Manual operated switch fuses, BS-type, 100 A
Including terminal bolt set M8x25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.
OS100...160GB03P

G = Gamma range from switch fuses 100 Amperes

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

04
Front operated
Number
OS100...160GB03N3P
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
100 A2-A41) 2 OS100GB02 1SCA116793R1001
100 A2-A41) 3 OS100GB03 1SCA116975R1001
100 A2-A41) 3+N OS100GB03N3 1SCA125530R1001
100 A2-A41) 4 OS100GB04N1 1SCA116976R1001
With 161 mm shaft and external handle OHB65J6
100 A2-A41) 2 OS100GB02P 1SCA116723R1001
100 A2-A41) 3 OS100GB03P 1SCA114613R1001
100 A2-A41) 3+N OS100GB03N3P 1SCA125531R1001
100 A2-A41) 4 OS100GB04N1P 1SCA114614R1001
With direct mount handle OSV200BK
100 A2-A41) 3 OS100GB03K 1SCA116747R1001
100 A2-A41) 4 OS100GB04N1K 1SCA116748R1001

Side operated
Shaft and handle not included
100 A2-A41) 3 OS100GBS30 1SCA116758R1001
100 A2-A41) 4 OS100GBS40N1 1SCA116759R1001
With 161 mm shaft and external handle OHB65J6E00S
100 A2-A41) 3 OS100GBS30P 1SCA114656R1001
100 A2-A41) 4 OS100GBS40N1P 1SCA114657R1001
1)
Max. fuse diameter 32 mm


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM100G…160G Long type 3 OSS160GG1L/3 1SCA114764R1001
OS/OSM100G...160G Short type 3 OSS160GG1S/3 1SCA114766R1001
OS/OSM100G...160G Long type 4 OSS160GG1L/4 1SCA114765R1001
OS/OSM100G...160G Short type 4 OSS160GG1S/4 1SCA114767R1001
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM100G…250_ Long type 3+N OTS250G1L 1SCA022715R5340
N3_
OS/OSM100G…250_ Short type 3+N OTS250G1S 1SCA022715R5260
N3_
41 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for BS-type, 125 A


Manual operated switch fuses, BS-type, 125 A
Including terminal bolt set M8x25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.

OS100...160GB03P
G = Gamma range from switch fuses 125 Amperes

N1 = Non-fused switched neutral on the left side


F = Swithced fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated

Rated current [A] Fuse size Number of poles Type Order number
OS100...160GB03N3P
Shaft and handle not included
125 A2-A41) 2 OS125GB02 1SCA116794R1001
125 A2-A41) 3 OS125GB03 1SCA115633R1001
125 A2-A41) 3+N OS125GB03N3 1SCA122007R1001
125 A2-A41) 4 OS125GB04N1 1SCA115900R1001
With 161 mm shaft and external handle OHB65J6
125 A2-A41) 2 OS125GB02P 1SCA116724R1001
125 A2-A41) 3 OS125GB03P 1SCA115634R1001
125 A2-A41) 3+N OS125GB03N3P 1SCA122008R1001
125 A2-A41) 4 OS125GB04N1P 1SCA115901R1001
With direct mount handle OSV200BK
125 A2-A41) 3 OS125GB03K 1SCA116751R1001
125 A2-A41) 4 OS125GB04N1K 1SCA116752R1001

Side operated
Shaft and handle not included
125 A2-A41) 3 OS125GBS30 1SCA116048R1001
125 A2-A41) 4 OS125GBS40N1 1SCA115959R1001
With 161 mm shaft and external handle OHB65J6E00S
125 A2-A41) 3 OS125GBS30P 1SCA114658R1001
125 A2-A41) 4 OS125GBS40N1P 1SCA114659R1001
With direct mount handle OHB65D6
125 A2-A41) 3 OS125GBS30K 1SCA116400R1001
125 A2-A41) 4 OS125GBS40N1K 1SCA115926R1001
1)
Max. fuse diameter 32 mm.


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Suitable for switches Description Number of poles Type Order number


OS/OSM100G…160G Long type 3 OSS160GG1L/3 1SCA114764R1001
OS/OSM100G...160G Short type 3 OSS160GG1S/3 1SCA114766R1001
OS/OSM100G...160G Long type 4 OSS160GG1L/4 1SCA114765R1001
OS/OSM100G...160G Short type 4 OSS160GG1S/4 1SCA114767R1001
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM100G…250_N3_ Long type 3+N OTS250G1L 1SCA022715R5340
OS/OSM100G…250_N3_ Short type 3+N OTS250G1S 1SCA022715R5260
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 42


Manual operated switch fuses, IEC
Ordering information for BS-type, 160 A


Manual operated switch fuses, BS-type, 160 A
Including terminal bolt set M8x25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.

G = Gamma range from switch fuses 160 Amperes


OS100...160GB03P

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

04
Front operated

Rated current [A] Fuse size Number of poles Type Order number
Shaft and handle not included
OS100...160GB03N3P
160 A2-A41) 2 OS160GB02 1SCA116795R1001
160 A2-A41) 3 OS160GB03 1SCA115412R1001
160 A2-A41) 3+N OS160GB03N3 1SCA122009R1001
160 A2-A41) 4 OS160GB04N1 1SCA115895R1001
160 A2-A41) 4 OS160GB04F 1SCA115418R1001
With 161 mm shaft and external handle OHB65J6
160 A2-A41) 2 OS160GB02P 1SCA116725R1001
160 A2-A41) 3 OS160GB03P 1SCA115413R1001
160 A2-A41) 3+N OS160GB03N3P 1SCA122010R1001
160 A2-A41) 4 OS160GB04N1P 1SCA115896R1001
160 A2-A41) 4 OS160GB04FP 1SCA115419R1001
With direct mount handle OSV200BK
160 A2-A41) 3 OS160GB03K 1SCA116753R1001
160 A2-A41) 4 OS160GB04N1K 1SCA116754R1001

Side operated
Shaft and handle not included
160 A2-A41) 3 OS160GBS30 1SCA115960R1001
160 A2-A41) 4 OS160GBS40N1 1SCA115961R1001
With 161 mm shaft and external handle OHB65J6E00S
160 A2-A41) 3 OS160GBS30P 1SCA114660R1001
160 A2-A41) 4 OS160GBS40N1P 1SCA114661R1001
With direct mount handle OHB65D6
160 A2-A41) 3 OS160GBS30K 1SCA115927R1001
160 A2-A41) 4 OS160GBS40N1K 1SCA115928R1001
1)
Max. fuse diameter 32 mm.


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Suitable for switches Description Number of poles Type Order number


OS/OSM100G…160G Long type 3 OSS160GG1L/3 1SCA114764R1001
OS/OSM100G...160G Short type 3 OSS160GG1S/3 1SCA114766R1001
OS/OSM100G...160G Long type 4 OSS160GG1L/4 1SCA114765R1001
OS/OSM100G...160G Short type 4 OSS160GG1S/4 1SCA114767R1001
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM100G…250_N3_ Long type 3+N OTS250G1L 1SCA022715R5340
OS/OSM100G…250_N3_ Short type 3+N OTS250G1S 1SCA022715R5260
43 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for BS-type, 200 A


Manual operated switch fuses, BS-type, 200 A
BS-fuse type dedicated Gamma-generation switch with rated operational current AC21-23A,
160A. Including terminal bolt set M8x25. Mechanism located at the end of the switch. The
handles are IP65 protected, pavdlockable in the OFF-position and with door interlock in the
OS200GB03P ON-position.

G = Gamma range from switch fuses 200 Amperes

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated
OS200GB03N3P
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
160 A2-A41) 3 OS200GB03 1SCA123903R1001
160 A2-A41) 3+N OS200GB03N3 1SCA123904R1001
160 A2-A41) 4 OS200GB04N1 1SCA125491R1001
OSS200G1L
With 161 mm shaft and external handle OHB65J6
160 A2-A41) 3 OS200GB03P 1SCA125468R1001
160 A2-A41) 3+N OS200GB03N3P 1SCA126216R1001
160 A2-A41) 4 OS200GB04N1P 1SCA125493R1001
With direct mount handle OSV200BK
OSS200G1S
160 A2-A41) 3 OS200GB03K 1SCA128085R1001
160 A2-A41) 3+N OS200GB03N3K 1SCA128087R1001
1)
Max. fuse diameter 32 mm.


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM200 Long type 3 OSS200G1L/3 1SCA022731R8910
OS/OSM200 Short type 3 OSS200G1S/3 1SCA022732R0130
OS/OSM200 Long type 4 OSS200G1L/4 1SCA022731R9040
OS/OSM200 Short type 4 OSS200G1S/4 1SCA022732R0050
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM100G…250_N3_ Long type 3+N OTS250G1L 1SCA022715R5340
OS/OSM100G…250_N3_ Short type 3+N OTS250G1S 1SCA022715R5260
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 44


Manual operated switch fuses, IEC
Ordering information for BS-type, 100...200 A


Manual operated switch fuses, BS-type, 100…200 A with integrated nuts
The types -42 have integrated nuts for ease of installation. Including terminal bolt set.
Mechanism located at the end of the switch. The handles are IP65 protected, padlockable in
the OFF-position and with door interlock in the ON-position.

G = Gamma range from switch fuses from 100 to 200 Amperes


Terminals with integrated nuts
N3 = Detachable neutral link integrated into the mechanism

Front operated
Number
Rated current [A] Fuse size of poles Type Order number

04
Shaft and handle not included
100 A2-A41) 3 OS100GB03-42 1SCA128216R1001
100 A2-A41) 3+N OS100GB03N3-42 1SCA129906R1001
125 A2-A41) 3 OS125GB03-42 1SCA128214R1001
OS100...200GB03P-42
125 A2-A41) 3+N OS125GB03N3-42 1SCA129911R1001
160 A2-A41) 3 OS160GB03-42 1SCA128212R1001
160 A2-A41) 3+N OS160GB03N3-42 1SCA129915R1001
200 A2-A41) 3 OS200GB03-42 1SCA128210R1001
200 A2-A41) 3+N OS200GB03N3-42 1SCA129921R1001
With 161 mm shaft and external handle OHB65J6
100 A2-A41) 3 OS100GB03N3P-42 1SCA129907R1001
100 A2-A41) 3+N OS100GB03P-42 1SCA128217R1001
OS100...160GB12P-42 125 A2-A41) 3 OS125GB03N3P-42 1SCA129912R1001
125 A2-A41) 3+N OS125GB03P-42 1SCA128215R1001
160 A2-A41) 3 OS160GB03N3P-42 1SCA129916R1001
160 A2-A41) 3+N OS160GB03P-42 1SCA128213R1001
200 A2-A41) 3 OS200GB03N3P-42 1SCA129922R1001
200 A2-A41) 3+N OS200GB03P-42 1SCA128211R1001
1)
Max. fuse diameter 32 mm.

OS100...200GB03N3P-42 —
Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

OSS250G1SH Number
Suitable for switches Description of poles Type Order number
OS/OSM100G…160G Long type 3 OSS160GG1L/3 1SCA114764R1001
OS/OSM100G…160G Short type 3 OSS160GG1S/3 1SCA114766R1001
OS/OSM100G…160G Long type 4 OSS160GG1L/4 1SCA114765R1001
OS/OSM100G…160G Short type 4 OSS160GG1S/4 1SCA114767R1001
OS/OSM200 Long type 3 OSS200G1L/3 1SCA022731R8910
OS/OSM200 Short type 3 OSS200G1S/3 1SCA022732R0130
OS/OSM200 Long type 4 OSS200G1L/4 1SCA022731R9040
OS/OSM200 Short type 4 OSS200G1S/4 1SCA022732R0050
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM100G…250_N3_ Long type 3+N OTS250G1L 1SCA022715R5340
OS/OSM100G…250_N3_ Short type 3+N OTS250G1S 1SCA022715R5260
45 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for BS-type, 200 A


Manual operated switch fuses, BS-type, 200 A
Including terminal bolt set M8x25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
OS200...250B02P
position.

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated
OS200...250B03N3 Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
200 B1-B2 2 OS200B02 1SCA022769R7660
200 B1-B2 3 OS200B03 1SCA022717R3410
200 B1-B2 3+N OS200B03N3 1SCA022750R0540
200 B1-B2 4 OS200B04F 1SCA123706R1001
With 210 mm shaft and external handle OHB65J6
OS200...250BS30K 200 B1-B2 2 OS200B02P 1SCA022769R7820
200 B1-B2 3 OS200B03P 1SCA022709R9330
200 B1-B2 3+N OS200B03N3P 1SCA022750R0620
200 B1-B2 4 OS200B04FP 1SCA123704R1001
With direct mount handle OSV200BK
200 B1-B2 3 OS200B03K 1SCA022763R6950

Side operated
OS200...250BS40N2K
Shaft and handle not included
200 B1-B2 3 OS200BS30 1SCA022870R7770
200 B1-B2 4 OS200BS40F 1SCA022870R7930
With direct mount handle OHB65D6
200 B1-B2 3 OS200BS30K 1SCA022870R7850
200 B1-B2 4 OS200BS40FK 1SCA022870R8070
OSS200G1L


Recommended accessories: Shrouds
OSS200G1S Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM200 Long type 3 OSS200G1L/3 1SCA022731R8910
OSS250G1SH
OS/OSM200 Short type 3 OSS200G1S/3 1SCA022732R0130
OS/OSM200 Long type 4 OSS200G1L/4 1SCA022731R9040
OS/OSM200 Short type 4 OSS200G1S/4 1SCA022732R0050
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM100G…250_N3_ Long type 3+N OTS250G1L 1SCA022715R5340
OS/OSM100G…250_N3_ Short type 3+N OTS250G1S 1SCA022715R5260
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 46


Manual operated switch fuses, IEC
Ordering information for BS-type, 250 A


Manual operated switch fuses, BS-type, 250 A
I Including terminal bolt set M10X30. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
OS200...250B02P position.

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated

OS200...250B03N3 Number
Rated current [A] Fuse size of poles Type Order number

04
Shaft and handle not included
250 B1-B3 2 OS250B02 1SCA022769R9360
250 B1-B3 3 OS250B03 1SCA022750R6400
250 B1-B3 3+N OS250B03N3 1SCA022750R7980
250 B1-B3 4 OS250B04N1 1SCA022750R7040
250 B1-B3 4 OS250B04F 1SCA109110R1001
OS200...250BS30K
With 161 mm shaft and external handle OHB65J6
250 B1-B3 2 OS250B02P 1SCA022769R9440
250 B1-B3 3 OS250B03P 1SCA022750R6660
250 B1-B3 3+N OS250B03N3P 1SCA022750R8010
250 B1-B3 4 OS250B04N1P 1SCA022750R7120
250 B1-B3 4 OS250B04FP 1SCA109112R1001
With direct mount handle OSV200BK
250 B1-B3 3 OS250B03K 1SCA022763R6010
OS200...250BS40N2K
250 B1-B3 4 OS250B04N1K 1SCA022763R6100

Side operated
Shaft and handle not included
250 B1-B3 3 OS250BS30 1SCA022870R8580
250 B1-B3 4 OS250BS40F 1SCA022870R8740

OSS250G1L With direct mount handle OHB65D6


250 B1-B3 3 OS250BS30K 1SCA022870R8660
250 B1-B3 4 OS250BS40FK 1SCA022870R8820

OSS250G1SH

Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM250 Long type 3 OSS250G1L/3 1SCA022731R9390
OS/OSM250 Short type 3 OSS250G1S/3 1SCA022731R9550
OS/OSM250 Long type 4 OSS250G1L/4 1SCA022731R9470
OS/OSM250 Short type 4 OSS250G1S/4 1SCA022731R9630
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM100G…250_N3_ Long type 3+N OTS250G1L 1SCA022715R5340
OS/OSM100G…250_N3_ Short type 3+N OTS250G1S 1SCA022715R5260
47 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for BS-type, 315 A


Manual operated switch fuses, BS-type, 315 A
Including terminal bolt set M10x30. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.
OS315...400B03P

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
OS315BS30 Shaft and handle not included
315 B1-B4 2 OS315B02 1SCA022817R3370
315 B1-B4 3 OS315B03 1SCA022753R2070
315 B1-B4 3+N OS315B03N3 1SCA022753R9590
315 B1-B4 4 OS315B04F 1SCA022777R5480
With 200 mm shaft and external handle OHB95J12
315 B1-B4 2 OS315B02P 1SCA022817R3450
315 B1-B4 3 OS315B03P 1SCA022719R0680
OS315B04FP
315 B1-B4 3+N OS315B03N3P 1SCA022753R8940
315 B1-B4 4 OS315B04FP 1SCA022753R6650
With direct mount handle OSV400BK
315 B1-B4 3 OS315B03K 1SCA022763R6520
315 B1-B4 4 OS315B04N1K 1SCA022763R7170

Side operated
Shaft and handle not included
OS315BS03K
315 B1-B4 3 OS315BS30 1SCA022870R9390
315 B1-B4 4 OS315BS40F 1SCA022870R9550
With direct mount handle OHB95D12
315 B1-B4 3 OS315BS30K 1SCA022870R9470
315 B1-B4 4 OS315BS40FK 1SCA022870R9630
OSS250G1SH


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM315...400 Long type 3 OSS400G1L/3 1SCA022776R6650
OS/OSM315...400 Short type 3 OSS400G1S/3 1SCA022776R6900
OS/OSM315...400 Long type 4 OSS400G1L/4 1SCA022776R6730
OS/OSM315...400 Short type 4 OSS400G1S/4 1SCA022776R7030
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM315…400_N3_ Long type 3+N OSS250G1L 1SCA022727R5080
OS/OSM315…400_N3_ Short type 3+N OSS250G1S 1SCA022727R4940
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 48


Manual operated switch fuses, IEC
Ordering information for BS-type, 400 A


Manual operated switch fuses, BS-type, 400 A
Including terminal bolt set M8x25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.

OS315...400B03P
N1 = Non-fused switched neutral on the left side
F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated
Number
Rated current [A] Fuse size of poles Type Order number

04
Shaft and handle not included
OS400B03N3P 400 B1-B4 2 OS400B02 1SCA022813R7140
400 B1-B4 3 OS400B03 1SCA022737R4900
400 B1-B4 3+N OS400B03N3 1SCA022753R9830
400 B1-B4 4 OS400B04F 1SCA022754R4590
With 200 mm shaft and external handle OHB95J12
400 B1-B4 2 OS400B02P 1SCA022813R7220
400 B1-B4 3 OS400B03P 1SCA022719R0840
400 B1-B4 3+N OS400B03N3P 1SCA022753R9160
OS400B04FP 400 B1-B4 4 OS400B04FP 1SCA022753R6900
With direct mount handle OSV400BK
400 B1-B4 3 OS400B03K 1SCA022763R6790

Side operated
Shaft and handle not included
400 B1-B4 3 OS400BS30 1SCA022871R0130
400 B1-B4 4 OS400BS40F 1SCA022871R0300
OS400B03K With direct mount handle OHB95D12
400 B1-B4 3 OS400BS30K 1SCA022871R0210
400 B1-B4 4 OS400BS40FK 1SCA022871R0480

OSS250G1SH

Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS/OSM315...400 Long type 3 OSS400G1L/3 1SCA022776R6650
OS/OSM315...400 Short type 3 OSS400G1S/3 1SCA022776R6900
OS/OSM315...400 Long type 4 OSS400G1L/4 1SCA022776R6730
OS/OSM315...400 Short type 4 OSS400G1S/4 1SCA022776R7030
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM315…400_N3_ Long type 3+N OSS250G1L 1SCA022727R5080
OS/OSM315…400_N3_ Short type 3+N OSS250G1S 1SCA022727R4940
49 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for BS-type, 630 A


Manual operated switch fuses, BS-type, 630 A
Including terminal bolt set M12X40. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-posi-
tion.

OS630B02P N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
630 C1-C2 2 OS630B02 1SCA113528R1001
630 C1-C2 3 OS630B03 1SCA022825R5770
OS630B03N3P
630 C1-C2 3+N OS630B03N3 1SCA106295R1001
630 C1-C2 4 OS630B04N1 1SCA022837R7020
630 C1-C2 4 OS630B04F 1SCA022825R5930
With 280 mm shaft and external handle OHB145J12
630 C1-C2 2 OS630B02P 1SCA113529R1001
630 C1-C2 3 OS630B03P 1SCA022825R5850
630 C1-C2 3+N OS630B03N3P 1SCA100860R1001
630 C1-C2 4 OS630B04N1P 1SCA022837R7110
OS630B03K 630 C1-C2 4 OS630B04FP 1SCA022825R6070
With direct mount handle OSV800BK
630 C1-C2 3 OS630B03K 1SCA108708R1001
630 C1-C2 4 OS630B04FK 1SCA110317R1001

Side operated
Shaft and handle not included
630 C1-C2 3 OS630BS30 1SCA108147R1001
630 C1-C2 4 OS630BS40F 1SCA108149R1001
OS630BS30
With direct mount handle OHB145D12
630 C1-C2 3 OS630BS30K 1SCA108148R1001
630 C1-C2 4 OS630BS40FK 1SCA108150R1001


Recommended accessories: Shrouds
OS630BS40N2K
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OSS800G1S
OS/OSM600...800 Long type 3 OSS800G1L/3 1SCA022776R7200
OS/OSM600...800 Short type 3 OSS800G1S/3 1SCA022776R7540
OS/OSM600...800 Long type 4 OSS800G1L/4 1SCA022776R7380
OS/OSM600...800 Short type 4 OSS800G1S/4 1SCA022776R7460
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM630…800_N3_ Long type 3+N OTS800G1L 1SCA022776R7710
OS/OSM630…800_N3_ Short type 3+N OTS800G1S 1SCA022776R8010
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 50


Manual operated switch fuses, IEC
Ordering information for BS-type, 800 A


Manual operated switch fuses, BS-type, 800 A
Including terminal bolt set M12X40. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.

OS800B02P N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral
N3 = Detachable neutral link integrated into the mechanism

Front operated
Number
Rated current [A] Fuse size of poles Type Order number

04
Shaft and handle not included
800 C1-C3 2 OS800B02 1SCA022837R6560
800 C1-C3 3 OS800B03 1SCA022825R7470
OS800B03N3P 800 C1-C3 3+N OS800B03N3 1SCA110102R1001
800 C1-C3 4 OS800B04N1 1SCA022837R6050
800 C1-C3 4 OS800B04F 1SCA022825R7710
With 280 mm shaft and external handle OHB145J12
800 C1-C3 2 OS800B02P 1SCA022837R6480
800 C1-C3 3 OS800B03P 1SCA022825R7550
800 C1-C3 3+N OS800B03N3P 1SCA100861R1001
800 C1-C3 4 OS800B04N1P 1SCA022837R6130
800 C1-C3 4 OS800B04FP 1SCA022825R7800
OS800BS30
With direct mount handle OSV800BK
800 C1-C3 3 OS800B03K 1SCA108713R1001
800 C1-C3 4 OS800B04FK 1SCA110316R1001

Side operated
Shaft and handle not included
800 C1-C3 3 OS800BS30 1SCA108083R1001

OS800BS40N2K 800 C1-C3 4 OS800BS40F 1SCA108085R1001


With direct mount handle OHB145D12
800 C1-C3 3 OS800BS30K 1SCA108084R1001
800 C1-C3 4 OS800BS40FK 1SCA108102R1001

OSS800G1L —
Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

OSS800G1S Number
Suitable for switches Description of poles Type Order number
OS/OSM600...800 Long type 3 OSS800G1L/3 1SCA022776R7200
OS/OSM600...800 Short type 3 OSS800G1S/3 1SCA022776R7540
OS/OSM600...800 Long type 4 OSS800G1L/4 1SCA022776R7380
OS/OSM600...800 Short type 4 OSS800G1S/4 1SCA022776R7460
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS/OSM630…800_N3_ Long type 3+N OTS800G1L 1SCA022776R7710
OS/OSM630…800_N3_ Short type 3+N OTS800G1S 1SCA022776R8010
51 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for BS type, 1250 A


Manual operated switch fuses, BS type, 1250 A
Including terminal bolt set M12X50. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.

OS1250B03N3P
Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
12501) D1 2 OS1250B02 1SCA114069R1001
12501) D1 3 OS1250B03 1SCA105249R1001
12501) D1 3+N OS1250B03N3 1SCA127485R1001
12501) D1 4 OS1250B04F 1SCA105257R1001
OS1250B03N3K With 395 mm shaft and external handle OHB274J12
12501) D1 2 OS1250B02P 1SCA114070R1001
12501) D1 3 OS1250B03P 1SCA105250R1001
12501) D1 3+N OS1250B03N3P 1SCA107936R1001
12501) D1 4 OS1250B04FP 1SCA105258R1001
With direct mount handle OSV1250DK
12501) D1 3 OS1250B03K 1SCA108715R1001
1)
1250A / AC-20…22A, 1000A / AC-23A.


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number
Suitable for switches Description of poles Type Order number
OS1200...1250 Long type 3 OSS1250G1L/3 1SCA107938R1001
OS1200...1250 Short type 3 OSS1250G1S/3 1SCA107939R1001
OS1200...1250 Long type 4 OSS1250G1L/4 1SCA107940R1001
OS1200...1250 Short type 4 OSS1250G1S/4 1SCA107941R1001
Terminal shrouds suitable for mechanism with detachable integrated neutral (N3 versions)
OS1200...1250/OSM1250_N3_ Long type 3+N OTS1600G1L 1SCA106134R1001
OS1200...1250/OSM1250_N3_ Short type 3+N OTS1600G1S 1SCA102667R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 52


Special connected switch fuses, IEC
Ordering information for BS-type, 125...200 A


Special connected switch fuses, BS-type, 125...200 A
Including terminal bolt set M8x25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
position.
OS125G...160GB12LR

G = Gamma range from switch fuses from 125 to 160 Amperes

N1 = Non-fused switched neutral on the left side


N2 = Non-fused switched neutral on the right side
N3 = Detachable neutral link integrated into the mechanism
F = Switched fusible neutral

04
OS125GB21LR
Front operated with back in - back out connection
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
125 A2-A41) 3 OS125GB03BB 1SCA120782R1001
125 A2-A41) 4 OS125GB04BBN2 1SCA120784R1001
160 A2-A41) 3 OS160GB03BB 1SCA120656R1001
OS125GB22LR 160 A2-A41) 4 OS160GB04BBN2 1SCA120664R1001
200 B1-B22) 3 OS200B03BB 1SCA102083R1001
200 B1-B22) 4 OS200B04BBN2 1SCA102137R1001
With 161 mm shaft and external handle OHB65J6
125 A2-A41) 3 OS125GB03BBP 1SCA120783R1001
125 A2-A41) 4 OS125GB04BBN2P 1SCA120785R1001
160 A2-A41) 3 OS160GB03BBP 1SCA120657R1001
160 A2-A41) 4 OS160GB04BBN2P 1SCA120665R1001
OS125...160GB03BB
200 B1-B22) 3 OS200B03BBP 1SCA102082R1001
200 B1-B22) 4 OS200B04BBN2P 1SCA102123R1001
1)
Max fuse diameter 32 mm.

Front operated with left in - right out connection


Shaft and handle not included
OS200B03BB 125 A2-A41) 3 OS125GB12LR 1SCA120257R1001
125 A2-A41) 4 OS125GB21LR 1SCA120259R1001
125 A2-A41) 4 OS125GB22LR 1SCA120264R1001
160 A2-A4 1)
3 OS160GB12LR 1SCA123716R1001
160 A2-A41) 4 OS160GB21LR 1SCA120272R1001
160 A2-A41) 4 OS160GB22LR 1SCA120276R1001
With 161 mm shaft and external handle OHB65J6
125 A2-A41) 3 OS125GB12LRP 1SCA120258R1001
125 A2-A41) 4 OS125GB21LRP 1SCA120261R1001
125 A2-A41) 4 OS125GB22LRP 1SCA120265R1001
160 A2-A41) 3 OS160GB12LRP 1SCA120271R1001
160 A2-A41) 4 OS160GB21LRP 1SCA120273R1001
160 A2-A41) 4 OS160GB22LRP 1SCA120277R1001
53 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses, IEC
Ordering information for BS-type, 250...400 A


Special connected switch fuses, BS-type, 250...400
Including terminal bolt set M10X30. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-
OS250B12LR position.

N2 = Non-fused switched neutral on the right side

Front operated with back in- back out connection


Number of
Rated current [A] Fuse size poles Type Order number
Shaft and handle not included
250 B1-B3 3 OS250B03BB 1SCA102173R1001
OS250...400B03BB
250 B1-B3 4 OS250B04BBN2 1SCA102175R1001
With 161 mm shaft and external handle OHB65J6
250 B1-B3 3 OS250B03BBP 1SCA102168R1001
250 B1-B3 4 OS250B04BBN2P 1SCA102164R1001

Front operated with left in-right out connection


Shaft and handle not included
250 B1-B3 3 OS250B12LR 1SCA022854R5420
OS250...400B04BBN2
250 B1-B3 4 OS250B21LR 1SCA022854R5510
250 B1-B3 4 OS250B22LR 1SCA022854R7120
With 161 mm shaft and external handle OHB65J6
250 B1-B3 3 OS250B12LRP 1SCA022854R5690
250 B1-B3 4 OS250B21LRP 1SCA022854R5850
250 B1-B3 4 OS250B22LRP 1SCA022854R7210

Front operated with back in- back out connection

OS400B03BB Number of
Rated current [A] Fuse size poles Type Order number
Shaft and handle not included
400 B1-B4 3 OS400B03BB 1SCA102250R1001
400 B1-B4 4 OS400B04BBN2 1SCA102239R1001
With 161 mm shaft and external handle OHB65J6
400 B1-B4 3 OS400B03BBP 1SCA102252R1001
400 B1-B4 4 OS400B04BBN2P 1SCA102248R1001
OS400B04BB
Front operated with left in-right out connection
Shaft and handle not included
400 B1-B4 3 OS400B12LR 1SCA022855R1230
400 B1-B4 4 OS400B21LR 1SCA022855R1310
400 B1-B4 4 OS400B22LR 1SCA022855R2630
With 161 mm shaft and external handle OHB65J6
OS400B12LR 400 B1-B4 3 OS400B12LRP 1SCA022855R1400
400 B1-B4 4 OS400B21LRP 1SCA022855R1580
400 B1-B4 4 OS400B22LRP 1SCA022855R2710
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 54


Motorized switch fuses, IEC
Ordering information for BS type, 32...1250 A


Motorized switch fuses OSM, BS type, 32…1250 A
Including a handle for manual operation, bolt kit with nut and washers for all terminals
(100A…1250A), male connectors for control circuit and a handle and spare fuse storage clip.
OSM250B3N3M230C Type codes for motor voltage Ue = 220-240 VAC.

G = Gamma range from switch fuses from 32 to 160 Amperes

N2 = Non-fused switched neutral on the left side


N3 = Detachable neutral link integrated into the mechanism
Switched fusible neutral available on request.
OSM250B4N1M230C Front operated

04
Number of
Rated current [A] Fuse size poles Type Order number
Shaft and handle not included
32 A2-A3 3 OSM32GB3M230C 1SCA116662R1001
32 A2-A3 4 OSM32GB4N1M230C 1SCA118775R1001
63 A2-A3 3 OSM63GB3M230C 1SCA116657R1001

OSM315B3N3M230C 63 A2-A3 4 OSM63GB4N1M230C 1SCA118776R1001


100 A2-A4 3 OSM100GB3M230C 1SCA116679R1001
100 A2-A4 4 OSM100GB4N1M230C 1SCA118779R1001
125 A2-A4 3 OSM125GB3M230C 1SCA116677R1001
125 A2-A4 4 OSM125GB4N1M230C 1SCA118780R1001
160 A2-A4 3 OSM160GB3M230C 1SCA116670R1001
160 A2-A4 4 OSM160GB4N1M230C 1SCA118781R1001
200 B1-B2 3 OSM200B3M230C 1SCA104272R1001
200 B1-B2 3+N OSM200B3N3M230C 1SCA104323R1001
200 B1-B2 4 OSM200B4N1M230C 1SCA118784R1001
250 B1-B3 3 OSM250B3M230C 1SCA104287R1001
250 B1-B3 3+N OSM250B3N3M230C 1SCA104290R1001
250 B1-B3 4 OSM250B4N1M230C 1SCA118785R1001
315 B1-B4 3 OSM315B3M230C 1SCA104303R1001
315 B1-B4 3+N OSM315B3N3M230C 1SCA104306R1001
315 B1-B4 4 OSM315B4N1M230C 1SCA118788R1001
400 B1-B4 3 OSM400B3M230C 1SCA104310R1001
400 B1-B4 3+N OSM400B3N3M230C 1SCA104312R1001
400 B1-B4 4 OSM400B4N1M230C 1SCA118789R1001
630 C1-C2 3 OSM630B3M230C 1SCA104516R1001
630 C1-C2 3+N OSM630B3N3M230C 1SCA104535R1001
630 C1-C2 4 OSM630B4N1M230C 1SCA118791R1001
800 C1-C3 3 OSM800B3M230C 1SCA104520R1001
800 C1-C3 3+N OSM800B3N3M230C 1SCA104536R1001
800 C1-C3 4 OSM800B4N1M230C 1SCA118792R1001
1250 D1 3 OSM1250B3M230C 1SCA112552R1001
1250 D1 3+N OSM1250B3N3M230C 1SCA112550R1001
1250 D1 4 OSM1250B4N1M230C 1SCA118795R1001

Handles and bolt kits included as standard


Suitable for switches Handle+shaft kit
OSM32…63 OTV250EMK
OSM100…200 OTV250EMK
OSM250 OTV250EMK
OSM315…400 OTV400EMK
OSM630…800 OTV800EMK
OSM1250 OTV1000EMK
55 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses, IEC
Ordering information for NFC type, 25...50 A


Manual operated switch fuses, NFC type, 25…50 A
Protected tunnel terminals, IP20. Mechanism located at the end of the switch. The handles are
IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position.

OS50GF04FP
F = OS Mini range switch fuses from 25 to 32 Amperes
G = Gamma range from switch fuses 50 Amperes

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral

Front operated
Number
OS50GFS40FK Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
25 10x38 3 OS25FF1210-2 1SCA108801R1001
25 10x38 4 OS25FF2210N1-2 1SCA108806R1001
32 14x51 3 OS32FF1214-2 1SCA108888R1001
32 14x51 4 OS32FF2214N1-2 1SCA108889R1001
50 14x51 2 OS50GF02 1SCA116798R1001
50 14x51 3 OS50GF03 1SCA115490R1001
50 14x51 4 OS50GF04F 1SCA115497R1001
With 150 mm shaft and external handle OHB65J6
25 10x38 3 OS25FF1210 1SCA108636R1001
25 10x38 4 OS25FF2210N1 1SCA108638R1001
32 14x51 3 OS32FF1214 1SCA115498R1001
With 161 mm shaft and external handle OHB45J6
50 14x51 2 OS50GF02P 1SCA118345R1001
50 14x51 3 OS50GF03P 1SCA115492R1001
50 14x51 4 OS50GF04FP 1SCA115498R1001

Side operated
Shaft and handle not included
25 10x38 3 OS25FFS3010-2 1SCA108808R1001
32 14x51 3 OS32FFS3014-2 1SCA108890R1001
50 14x51 3 OS50GFS30 1SCA116050R1001
50 14x51 4 OS50GFS40F 1SCA116014R1001
With 70 mm shaft and external handle OHB65J6
25 10x38 3 OS25FFS3010 1SCA108639R1001
32 14x51 3 OS32FFS3014 1Sca108646R1001
With direct mount handle OHB65D6
50 14x51 3 OS50GFS30K 1SCA116404R1001
50 14x51 4 OS50GFS40FK 1SCA116425R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 56


Manual operated switch fuses, IEC
Ordering information for NFC type, 125 A


Manual operated switch fuses, NFC type, 125 A
Including terminal bolt set M8x25. Mechanism located at the end of the switch. The handles
are IP65 protected, padlockable in the OFF-position and with door interlock in the ON-posi-
tion.
OS125GFS40FK
G = Gamma range from switch fuses 125 Amperes

N1 = Non-fused switched neutral on the left side


F = Switched fusible neutral

Front operated

04
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
125 22x58 2 OS125GF02 1SCA116852R1001
125 22x58 3 OS125GF03 1SCA115601R1001
125 22x58 4 OS125GF04F 1SCA115605R1001
With 161 mm shaft and external handle OHB45J6
125 22x58 2 OS125GF02P 1SCA116727R1001
125 22x58 3 OS125GF03P 1SCA115602R1001
125 22x58 4 OS125GF04FP 1SCA115606R1001

Side operated
Shaft and handle not included
125 22x58 3 OS125GFS30 1SCA115973R1001
125 22x58 4 OS125GFS40F 1SCA115975R1001
With direct mount handle OHB65D6
125 22x58 3 OS125GFS30K 1SCA115944R1001
125 22x58 4 OS125GFS40FK 1SCA115946R1001


Recommended accessories: Shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
For more details see page 86.

Number of
Suitable for switches Description poles Type Order number
OS/OSM100G...160G Long type 3 OSS160GG1L/3 1SCA114764R1001
OS/OSM100G...160G Short type 3 OSS160GG1S/3 1SCA114766R1001
OS/OSM100G...160G Long type 4 OSS160GG1L/4 1SCA114765R1001
OS/OSM100G...160G Short type 4 OSS160GG1S/4 1SCA114767R1001
57 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated fusible disconnect switches, UL/CSA
Ordering information for CC and J types, 30 A


Manual operated fusible disconnect switches, CC and J types, 30 A
Protected tunnel terminals, IP20, cable size 0.5…10 mm2, (AWG 18 - 8). Mechanism at the end of
the switch. The handle is NEMA 1, 3R, 12 protected, padlockable in the OFF-position and with door
interlock in the ON-position.
OS30FACC12P
F = OS Mini range switch fuse 30 Amperes

F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
30 CC, 30 A 3 OS30FACC12 1SCA108813R1001
30 CC, 30 A 4 OS30FACC22F 1SCA108819R1001
30 J, 30 A 3 OS30FAJ12 1SCA108824R1001
30 J, 30 A 4 OS30FAJ22F 1SCA108829R1001
With 150 mm shaft and external handle OHB65J6
30 CC, 30 A 3 OS30FACC12P 1SCA108817R1001
30 J, 30 A 3 OS30FAJ12P 1SCA108828R1001
30 J, 30 A 4 OS30FAJ22FP 1SCA108831R1001

Side operated
Shaft and handle not included
30 CC, 30 A 3 OS30FACCS30 1SCA108822R1001
30 J, 30 A 3 OS30FAJS30 1SCA108834R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 58


Manual operated fusible disconnect switches, UL/CSA
Ordering information for J type, 60 A


Manual operated fusible disconnect switches, J type, 60 A
Protected tunnel terminals, IP20, cable size 2.5…25 mm2 (AWG 14 - 4). Mechanism at the end of
the switch. The handle is NEMA 1, 3R, 12 protected, padlockable in the OFF-position and with
door interlock in the ON-position.
OS60GJ03P
G = OS Gamma range switch fuse 60 Amperes

F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number

04
Shaft and handle not included
OS60GJ04FP
60 J, 60 A 2 OS60GJ02 1SCA121900R1001
60 J, 60 A 3 OS60GJ03 1SCA115866R1001
60 J, 60 A 4 OS60GJ04F 1SCA115445R1001
With 161 mm shaft and external handle OHB45J6
60 J, 60 A 2 OS60GJ02P 1SCA121901R1001
60 J, 60 A 3 OS60GJ03P 1SCA115443R1001
60 J, 60 A 4 OS60GJ04FP 1SCA115446R1001
OS60GJS40F With direct mount handle OSV200BK
60 J, 60 A 2 OS60GJ02K 1SCA121927R1001
60 J, 60 A 3 OS60GJ03K 1SCA122100R1001
60 J, 60 A 4 OS60GJ04FK 1SCA122098R1001

Side operated
Shaft and handle not included
60 J, 60 A 3 OS60GJS30 1SCA116051R1001

OS60GJS30K 60 J, 60 A 4 OS60GJS40F 1SCA115970R1001


With direct mount handle OHB65D6
60 J, 60 A 3 OS60GJS30K 1SCA116426R1001
60 J, 60 A 4 OS60GJS40FK 1SCA115941R1001
59 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated fusible disconnect switches, UL/CSA
Ordering information for J type, 100 A


Manual operated fusible disconnect switches, J type, 100 A
Included terminal bolt set M8X25. Mechanism at the end of the switch. The handle is NEMA 1,
3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-position.

G = OS Gamma range switch fuses 100 Amperes

OS100GJ03P F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
100 J, 100 A 2 OS100GJ02 1SCA121932R1001
100 J, 100 A 3 OS100GJ03 1SCA115436R1001
100 J, 100 A 4 OS100GJ04F 1SCA115438R1001
With 161 mm shaft and external handle OHB65J6
100 J, 100 A 2 OS100GJ02P 1SCA121933R1001
OS100GJ04FP 100 J, 100 A 3 OS100GJ03P 1SCA114639R1001
100 J, 100 A 4 OS100GJ04FP 1SCA115439R1001
With direct mount handle OSV200BK
100 J, 100 A 2 OS100GJ02K 1SCA125031R1001
100 J, 100 A 3 OS100GJ03K 1SCA121957R1001
100 J, 100 A 4 OS100GJ04FK 1SCA122093R1001

Side operated
Shaft and handle not included
100 J, 100 A 3 OS100GJS30 1SCA115971R1001
100 J, 100 A 4 OS100GJS40F 1SCA115972R1001
OS100GJS30
With direct mount handle OHB65D6
100 J, 100 A 3 OS100GJS30K 1SCA115942R1001
100 J, 100 A 4 OS100GJS40FK 1SCA115943R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 60


Manual operated fusible disconnect switches, UL/CSA
Ordering information for J type, 200 A


Manual operated fusible disconnect switches, J type, 200 A
Included terminal bolt set M8X25. Mechanism at the end of the switch. The handle is NEMA 1,
3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-position.

OS200J02P
F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
200 J, 200 A 2 OS200J02 1SCA107591R1001
200 J, 200 A 3 OS200J03 1SCA022733R6130

04
200 J, 200 A 4 OS200J04F 1SCA022758R9340
OS200J02P
With 210 mm shaft and external handle OHB65J6
200 J, 200 A 2 OS200J02P 1SCA107598R1001
200 J, 200 A 3 OS200J03P 1SCA022709R9760
200 J, 200 A 4 OS200J04FP 1SCA022758R9770
With direct mount handle OSV200BK
200 J, 200 A 3 OS200J03K 1SCA022763R5800

Side operated
OS200J04FP
Shaft and handle not included
200 J, 200 A 3 OS200JS30 1SCA022871R3910
200 J, 200 A 4 OS200JS40F 1SCA022871R4120
With direct mount handle OHB65D6
200 J, 200 A 3 OS200JS30K 1SCA022871R4040
200 J, 200 A 4 OS200JS40FK 1SCA022871R4210

OS200J02K

OS200J03K
61 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated fusible disconnect switches, UL/CSA
Ordering information for J type, 400 A


Manual operated fusible disconnect switches, J type, 400 A
Included terminal bolt set M10X40. Mechanism at the end of the switch. The handle is NEMA
1, 3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-
OS400J03P position.

F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
OS400J04FP
400 J, 400 A 2 OS400J02 1SCA107592R1001
400 J, 400 A 3 OS400J03 1SCA022755R0810
400 J, 400 A 4 OS400J04F 1SCA022755R3660
With 250 mm shaft and external handle OHB95J12
400 J, 400 A 2 OS400J02P 1SCA107596R1001
400 J, 400 A 3 OS400J03P 1SCA022719R1140
400 J, 400 A 4 OS400J04FP 1SCA022755R3740
OS400J02P With direct mount handle OSV200BK
400 J, 400 A 3 OS400J03K 1SCA117773R1001

Side operated
Shaft and handle not included
400 J, 400 A 3 OS400JS30 1SCA022871R4980
400 J, 400 A 4 OS400JS40F 1SCA022871R5100
OS400J04FP With direct mount handle OHB95D12
400 J, 400 A 3 OS400JS30K 1SCA022871R5010
400 J, 400 A 4 OS400JS40FK 1SCA022871R5280

OS400J03K

OS400J03P

OS400JS40FK
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 62


Manual operated fusible disconnect switches, UL/CSA
Ordering information for J type, 600 A


Manual operated fusible disconnect switches, J type, 600 A
Included terminal bolt set M8X25. Mechanism at the end of the switch. The handle is NEMA 1,
3R, 12 protected, padlockable in the OFF-position and with door interlock in the ON-position.

OS600J02P
F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
600 J, 600 A 2 OS600J02 1SCA107593R1001
OS600J02P 600 J, 600 A 3 OS600J03 1SCA022825R8610

04
600 J, 600 A 4 OS600J04F 1SCA022839R3900
With 280 mm shaft and external handle OHB145J12
600 J, 600 A 2 OS600J02P 1SCA107595R1001
600 J, 600 A 3 OS600J03P 1SCA022825R8870
600 J, 600 A 4 OS600J04FP 1SCA022839R4030
With direct mount handle OSV200BK

OS600J03P 600 J, 600 A 3 OS600J03K 1SCA117774R1001

Side operated
Shaft and handle not included
600 J, 600 A 3 OS600JS30 1SCA108111R1001
600 J, 600 A 4 OS600JS40F 1SCA108113R1001
With direct mount handle OHB95D12

OS600J04FP 600 J, 600 A 3 OS600JS30K 1SCA108112R1001


600 J, 600 A 4 OS600JS40FK 1SCA108114R1001

OS600JS30K
63 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated fusible disconnect switches, UL/CSA
Ordering information for L type, 800...1200 A


Manual operated fusible disconnect switches, L type, 800…1200 A
Included terminal bolt set OS800: M10X40, OS1200: M10X50. Mechanism at the end of the
switch. The handle is NEMA 1, 3R, 12 protected, padlockable in the OFF-position and with door
interlock in the ON-position.
OS800L04FP
F = Switched fusible neutral

Front operated
Number
Rated current [A] Fuse size of poles Type Order number
Shaft and handle not included
800 L, 800 A 2 OS800L02 1SCA116920R1001
800 L, 800 A 3 OS800L03 1SCA022825R9760
800 L, 800 A 4 OS800L04F 1SCA022839R5350
1200 L, 1200 A 2 OS1200L02 1SCA116924R1001
1200 L, 1200 A 3 OS1200L03 1SCA105467R1001
1200 L, 1200 A 4 OS1200L04F 1SCA105465R1001
With 280 mm shaft and external handle OHB145J12
800 L, 800 A 2 OS800L02P 1SCA116921R1001
800 L, 800 A 3 OS800L03P 1SCA022825R9920
800 L, 800 A 4 OS800L04FP 1SCA022839R5430
With 395 mm shaft and external handle OHB274J12
1200 L, 1200 A 2 OS1200L02P 1SCA116925R1001
1200 L, 1200 A 3 OS1200L03P 1SCA105468R1001
1200 L, 1200 A 4 OS1200L04FP 1SCA105466R1001
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 64

04
65 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Manual operated switch fuses 32…63
Selection overview

11
12

10

5
2
7

4
3
6
9
8

Accessory guide for OS32G...OS63G

1. Switch fuse 6. Pistol type handle 12. Terminal shroud


2. Shaft 7. Direct mounted handle
3. Module for 8. Electrical interlock
auxiliary contacts 9. Detachable neutral link
4. Auxiliary contact 10. Conversion kit
5. Fuse monitor 11. DIN rail mounting kit

Please note that listed accessories are not automatically included in your order.
Ordering information for accessories from pages 69-72, 74-75, 77-78, 81 and 84-96.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 66


Manual operated switch fuses 100...1250
Selection overview

14 5

3
13
1

04
4
8

10
7
6
11 9
12

Accessory guide for OS100...1250

1. Switch fuse 6. Module for auxiliary 10. Direct mount handle


2. Shaft contact 11. Detachable neutral link
3. Terminal clamp 7. Auxiliary contact 12. Electrical interlock
4. Fourth pole 8. Fuse monitor 13. Conversion kit
5. Terminal shroud 9. Pistol handle 14. DIN rail mounting kit

Please note that listed accessories are not automatically included in your order.
Ordering information for accessories from pages 69-72, 74-75, 77-78, 81 and 84-96.
67 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motor operated switch fuses OSM32G...OSM1250
Selection overview

3
3
2

4
6
7

Accessory guide for OSM32G...OSM1250

1. Motorized switch fuse 5. Fuse monitor


2. Terminal clamp 6. Detachable neutral link
3. Terminal shroud 7. Storage for handle and fuses
4. Auxiliary contact

Please note that listed accessories are not automatically included in your order.
Ordering information for accessories from pages 82-84, 86-88 and 92-93
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 68

04
69 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual operated switch fuses 32…1250 A
Ordering information for handles


Pistol handles for front operated switch fuses

Plastic pistol handles, IP 65, Nema type 1, 3R, 12


OHB65J6
Padlockable with 3 padlocks in the OFF-position, door interlock in the ON-position. Screw fixing-
from the back side of the handle ensures double insulation.

Colour Handle length [mm] Type Order number Weight/unit [kg]

OHY65J6 For shaft diameter 6 mm (for OSMini and OS32...250)


Black and red-yellow: I-O/ON-OFF, grey: I-O.
Black 45 OHB45J6 1SCA022380R8770 0.12
Red-yellow 45 OHY45J6 1SCA022380R8930 0.12
Grey 45 OHG45J6 1SCA022380R8850 0.12

OHG65J6 Black 65 OHB65J6 1SCA022380R9660 0.12


Red-yellow 65 OHY65J6 1SCA022380R9820 0.12
Grey 65 OHG65J6 1SCA022380R9740 0.12
Black 80 OHB80J6 1SCA022381R0240 0.14
Black and red-yellow: Test/I-O/ON-OFF, grey: Test/I-O.
Black 45 OHB45J6T 1SCA109870R1001 0.12
OHB95J12
Black 65 OHB65J6T 1SCA022399R8110 0.12
Red-yellow 65 OHY65J6T 1SCA022456R9540 0.12
Grey 65 OHG65J6T 1SCA022456R9620 0.12
Black 80 OHB80J6T 1SCA022399R8290 0.14

For shaft diameter 12 mm (for OS315...400)


OHY95J12T Black and red-yellow: I-O/ON-OFF, grey: I-O.
Black 95 OHB95J12 1SCA022381R0830 0.16
Red-yellow 95 OHY95J12 1SCA022381R1050 0.16
Grey 95 OHG95J12 1SCA022381R0910 0.16
Indication: Test-OFF-ON/Test-O-I
Black 95 OHB95J12T 1SCA022736R1750 0.16
OHB125J12 Red-yellow 95 OHY95J12T 1SCA022736R1910 0.16

For shaft diameter 12 mm (for OS630...800)


Black and red-yellow: I-O/ON-OFF, grey: I-O.
Black 125 OHB125J12 1SCA022381R1560 0.16
Red-yellow 125 OHY125J12 1SCA022381R1720 0.16
Grey 125 OHG125J12 1SCA022381R1640 0.16
Black 145 OHB145J12 1SCA022381R2110 0.17
Red-yellow 145 OHY145J12 1SCA022381R2370 0.17
Grey 145 OHG145J12 1SCA022381R2290 0.17
Black 175 OHB175J12 1SCA022381R2450 0.18
Red-yellow 175 OHY175J12 1SCA022381R2700 0.18
Grey 175 OHG175J12 1SCA022381R2610 0.18
Indication: Test-OFF-ON/Test-O-I
Black 125 OHB125J12T 1SCA022652R2220 0.16
Red-yellow 125 OHY125J12T 1SCA022652R2310 0.16
Black 145 OHB145J12T 1SCA022652R2570 0.17
Red-yellow 145 OHY145J12T 1SCA022652R2650 0.17
Black 175 OHB175J12T 1SCA022708R0740 0.18

- Door interlocking in the ON-position means that the door cannot be opened, when the handle is in the ON-position.
This can be defeated to allow authorized personnel access for inspection.
- Handles padlockable in all positions and NEMA4/4X handles are available on request.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 70


Accessories for manual operated switch fuses 32…1250 A
Ordering information for handles


Pistol handles for front operated switch fuses
OHB274/330J12
Plastic pistol handles, IP 65, Nema type 1, 3R, 12
Padlockable with 3 padlocks in the OFF-position, door interlock in the ON-position. Screw
fixing from the back side of the handle ensures double insulation.

OHY274J12 Colour Handle length [mm] Type Order number Weight/unit [kg]

For shaft diameter 12 mm (for OS1200...1250)


Black and red-yellow: I-O/ON-OFF.
Black 274 OHB274J12 1SCA115920R1001 0.54

04
Red-yellow 274 OHY274J12 1SCA115919R1001 0.54

OHM_ Black 330 OHB330J12 1SCA115922R1001 0.58


Red-yellow 330 OHY330J12 1SCA115921R1001 0.58
Black 2x150 OHB150J12P 1SCA022865R9430 0.17
Red-yellow 2x150 OHY150J12P 1SCA101586R1001 0.17
Black 2x200 OHB200J12P 1SCA022865R9510 0.40
Red-yellow 2x200 OHY200J12P 1SCA101587R1001 0.40
Indication: Test-OFF-ON/Test-O-I
Black 274 OHB274J12T 1SCA120250R1001 0.54
Black 330 OHB330J12T 1SCA120252R1001 0.58
Black 2x200 OHB200J12PT 1SCA106510R1001 0.40
Red-yellow 2x200 OHY200J12PT 1SCA111512R1001 0.40
- Door interlocking in the ON-position means that the door cannot be opened, when the handle is in the
ON-position. This can be defeated to allow authorized personnel access for inspection.
- Handles padlockable in all positions and NEMA4/4X handles are available on request.

Stainless steel pistol handles, IP66, NEMA 4X


Padlockable with 3 padlocks in the OFF-position, door interlock in the ON-position, indication:
I-O/ON-OFF

Colour Handle length [mm] Type Order number Weight/unit [kg]

For shaft diameter 6 mm (for OSMini and OS32...250)


Metallic 45 OHM45L6 1SCA111295R1001 0.70
Metallic 65 OHM65L6 1SCA022739R1070 0.73
For shaft diameter 12 mm
Metallic 125 OHM125L12 1SCA022739R1150 0.76
Metallic 175 OHM175L12 1SCA022739R1230 0.83
Metallic 275 OHM275L12 1SCA022832R4840 0.96
71 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual operated switch fuses 32…1250 A
Ordering information for handles


Pistol handles for side operated switch fuses

Plastic pistol handles, IP 65, Nema type 1, 3R, 12


For mounting on the side of the enclosure. Padlockable with three padlocks in the OFF-position,
OHB65J6E00S
door interlock in the ON-position, IP 65. The position indications are rotated 90°. If the handle is
mounted on the front of the door, a standard handle can be used as well.

Weight/unit
Colour Handle length [mm] Type Order number [kg]

For shaft diameter 6 mm

OHY65J6E00S Plastic handles, black and red-yellow: I-O/ON-OFF, grey: I-O.


Black 65 OHB65J6E00S 1SCA022382R9850 0.12
Red-yellow 65 OHY65J6E00S 1SCA022382R9930 0.12
Grey 65 OHG65J6E00S 1SCA022383R4510 0.12
Plastic handles, black and red-yellow: Test/I-O/ON-OFF, grey: Test/I-O.
Black 65 OHB65J6TE00S 1SCA109016R1001 0.12
OHZX14
Red-yellow 65 OHY65J6TE00S 1SCA022688R0140 0.12
Grey 65 OHG65J6TE00S 1SCA109014R1001 0.12

For shaft diameter 12 mm


Plastic handles, indication I-O/ON-OFF
Black 145 OHB145J12E00S 1SCA022679R9700 0.17
- Door interlocking in the ON-position means that the door cannot be opened, when the handle is in the ON-position.
This can be defeated to allow authorized personnel access for inspection.
- Handles padlockable in all positions are available on request.

Extension ring for pistol handles


Suitable Weight/unit
for handles Colour Type Order number [kg]
OHB_ Black OHZX14 1SCA022851R6590 0.06
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 72


Accessories for manual operated switch fuses 32…1250 A
Ordering information for handles


Direct mount handles for front operated switch fuses
Panel board handle, can be padlocked in the OFF-position. Includes a special shaft. The handle
can also be used with a standard shaft as padlocking device.

Suitable Weight/unit
OSV250DK for switches Colour Type Order number [kg]

Suitable for OS 32G...1250


Indication: Test OFF-ON/Test O-I indication Padlockable with three padlocks in the OFF-position, optionally also in
the ON-position. Includes shaft and mechanism cover.
OS32G...160G, OS200J Black OSV200BK 1SCA022779R7530 0.14
OS200B/J_K Red-yellow OSVY200BK 1SCA022779R7700 0.14

04
OS200D…250D/B_K Black OSV250DK 1SCA022763R3510 0.16

OSV400DK OS200D…250D/B_K Red-yellow OSVY250DK 1SCA022778R6500 0.16


OS400D_K Black OSV400DK 1SCA022763R4230 0.34
OS400D_K Red-yellow OSVY400DK 1SCA022779R5590 0.34
OS315…400B/J_K Black OSV400BK 1SCA022763R3930 0.33
OS315…400B/J_K Red-yellow OSVY400BK 1SCA022779R5830 0.33
OS600…800_K Black OSV800DK 1SCA107794R1001 1.1
OS600…800_K Red-yellow OSVY800DK 1SCA108703R1001 1.1
OS1200...OS1250_K Black OSV1250DK 1SCA107797R1001 1.5
OS1200...OS1250_K Red-yellow OSVY1250DK 1SCA108702R1001 1.5


Direct mount handles for side operated switch fuses
Panel board handle, can be padlocked in the OFF-position. Includes a special shaft. The handle
can also be used with a standard shaft as padlocking device.
OSV1250DK
Suitable for OS Mini
Padlockable with three padlocks in the OFF- position when the door is open. Max. bail dia 6 mm.
OS20F…40F_ Black OHB4 1SCA022439R4050 0.05

Fuse replacement handles


OHB4
Weights/unit
For DIN-fuse sizes Type Order number [kg]
000,00,1,2,3 OFAE506 1SCA128175R1001 0.2

OFAE506
73 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for switch fuses OS Mini 20…40 A
Ordering information for shafts


Extended shafts

OXP6X_

Shaft Front Side Weight/


length operated operated unit
[mm] H [mm] H [mm] Type Order number [kg]
For OS 16...35 (Mini)2), shaft diameter 6 mm
OXP_X_-45 150 135...210 154...166 OXP6X1505) 1SCA022295R5600 0.05
170 155...230 174...186 OXP6X170 1SCA108224R1001 0.05
265 250...325 269...281 OXP6X265 1SCA108225R1001 0.08
400 385...460 404...416 OXP6X400 1SCA108226R1001 0.12
150 135...210 154...166 OXP6X150-451) 1SCA022294R4400 0.05
170 155...230 174...186 OXP6X170-451) 1SCA108227R1001 0.05
265 380...460 269...281 OXP6X265-451) 1SCA108228R1001 0.08
400 380...460 404...416 OXP6X400-451) 1SCA108229R1001 0.12
For OS 40 (Mini) , shaft diameter 6 mm
2)

150 135...210 235...243 OXP6X1505) 1SCA022295R5600 0.05


170 155...230 255...363 OXP6X170 1SCA108224R1001 0.05
265 250...325 352...360 OXP6X265 1SCA108225R1001 0.08
400 385...460 487...495 OXP6X400 1SCA108226R1001 0.12
150 135...210 235...243 OXP6X150-451) 1SCA022294R4400 0.05
170 155...230 255...363 OXP6X170-451) 1SCA108227R1001 0.05
265 250...325 352...360 OXP6X265-451) 1SCA108228R1001 0.08
400 385...460 487...495 OXP6X400-451) 1SCA108229R1001 0.12
For OS 32G...63G , shaft diameter 6 mm
4)

63 161…167 OXP6X63 1SCA111010R1001 0.02


90 188…194 OXP6X90 1SCA022064R1180 0.03
130 127…1746) 228…234 OXP6X130 1SCA022057R0570 0.04
161 138…205 OXP6X1613) 1SCA022067R1760 0.05
210 187…254 OXP6X210 1SCA022295R6080 0.06
290 267…334 OXP6X290 1SCA022042R6370 0.08
360 337…404 OXP6X360 1SCA022042R6530 0.10
430 407…474 OXP6X430 1SCA022056R6030 0.12
210 187…254 OXP6X210-451) 1SCA022294R4230 0.06
290 267…334 OXP6X290-451) 1SCA022304R4290 0.08
360 337…404 OXP6X360-451) 1SCA022341R4640 0.10
1)
The shaft position is rotated 45 degrees.
2)
Side operated, 4-pole: add 36 mm.
3)
Included as standard in P-types.
4)
Side operated 3-pole OS60GJ: add 33mm, 4-pole types: OS32…63GD/GB: add 23.5 mm, OS60GJ: add 68mm.
5)
Included as standard in front operated types.
6)
OS32…63GB/GF: 115…174.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 74


Accessories for manual operated switch fuses 32…1250 A
Ordering information for shafts


Extended shafts

OXP6X_

Shaft Front Side Weight/


length operated operated unit
[mm] H [mm] H [mm] Type Order number [kg]
For OS100G...160G2) , shaft diameter 6 mm

OXP_X_-45 63 161…167 OXP6X63 1SCA111010R1001 0.02


90 188…194 OXP6X90 1SCA022064R1180 0.03
130 127…1744) 228…234 OXP6X130 1SCA022057R0570 0.04

04
161 138…205 OXP6X1613) 1SCA022067R1760 0.05
210 187…254 OXP6X210 1SCA022295R6080 0.06
290 267…334 OXP6X290 1SCA022042R6370 0.08
360 337…404 OXP6X360 1SCA022042R6530 0.10
OHP12X_ 430 407…474 OXP6X430 1SCA022056R6030 0.12
210 187…254 OXP6X210-451) 1SCA022294R4230 0.06
290 267…334 OXP6X290-451) 1SCA022304R4290 0.08
360 337…404 OXP6X360-451) 1SCA022341R4640 0.10
For OS 200...250 DIN-type, shaft diameter 6 mm
161 160...205 321...327 OXP6X161 1SCA022067R1760 0.05
210 189...254 370...376 OXP6X2103) 1SCA022295R6080 0.06
290 269...334 OXP6X290 1SCA022042R6370 0.08
For OS 200...250 BS-type, shaft diameter 6 mm
161 140…205 321...327 OXP6X161 1SCA022067R1760 0.05
210 189…254 370...376 OXP6X210 3)
1SCA022295R6080 0.06
290 269…334 OXP6X290 1SCA022042R6370 0.08
For OS 315...400, shaft diameter 12 mm
250 230…325 489...495 OXP12X2503) 1SCA022325R6980 0.30
280 260…355 519...525 OXP12X280 1SCA022137R5140 0.30
325 305…400 OXP12X325 1SCA022042R5810 0.36
395 375…470 OXP12X395 1SCA022042R5990 0.43
465 445…540 OXP12X465 1SCA022042R6020 0.51
535 515…610 OXP12X535 1SCA022042R6110 0.59
1)
The shaft position is rotated 45 degrees.
2)
Side operated, 4-pole: add 35 mm.
3)
Included as standard in P-types.
4)
OS100GJ: 113…174, OS100GB…160GB: 121…174.
75 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual operated switch fuses 32…1250 A
Ordering information for shafts


Extended shafts

OXP12X_

Shaft Front Side Weight/


length operated operated unit
[mm] H [mm] H [mm] Type Order number [kg]
For OS 630...800, shaft diameter 12 mm
OXP12X250-45 280 258...382 645...651 OXP12X2802) 1SCA022137R5140 0.30
325 303...427 OXP12X325 1SCA022042R5810 0.40
395 373...497 OXP12X395 1SCA022042R5990 0.50
465 443...567 OXP12X465 1SCA022042R6020 0.60
535 513...637 OXP12X535 1SCA022042R6110 0.70
280 258...382 OXP12X280-45 1)
1SCA022382R0800 0.30

OETLZX95 325 303...427 OXP12X325-451) 1SCA022304R4450 0.40


For OS 1200...1250, shaft diameter 12 mm
395 366…4953) 371...5004) OXP12X3952) 1SCA022042R5990 0.43
465 436…565 3)
441...570 4)
OXP12X465 1SCA022042R6020 0.51
535 506…6353) 441...5714) OXP12X535 1SCA022042R6110 0.59
1)
The shaft position is rotated 45 degrees.
2)
Included as standard in front operated P-types.
3)
H with handle OH_274/330J12.
4
H with handle OHB150/200J12P.


Shaft extension socket
For extending the shaft of combination attachment.

Suitable for shaft Weight/


with diameter [mm] Type Order number unit [kg]
12 OETLZX95 1SCA022083R5620 0.04
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 76


Accessories for switch fuses OS Mini 20…40 A
Ordering information for auxiliary contacts


Auxiliary contacts for OS20F_…40F_ (OS Mini)
Units/type = 1 piece

Weight/unit
Description Type Order number [kg]
OA4B10
Mounting to the switch mechanism
Change over contacts
Auxiliary/test contacts. Max. two change over contacts.
See function chart below OA4B1C 1SCA022193R0150 0.03
Single pole contacts
> 3 mm contact gap.

04
1 NO OA4B10 1SCA022276R9050 0.03
1 NC OA4B01 1SCA022276R9210 0.03
OA3G01

Mounting on the side of the switch


Mounting on the side of the switch with aux.contact frame OESAZX 169
1NO MCB-10 1SCA022150R5110 0.03
1NC MCB-01 1SCA022150R5370 0.03
Snap-on mounting on the switch, by using a frame OSZ4, IP20
NO contacts are provided with a positive opening feature.
Types _AU have gold plated contacts for harsh environments and low operating voltages.
1 NO OA1G10 1SCA022353R4970 0.03
1 NC OA3G01 1SCA022456R7410 0.03
1 NO OA1G10AU 1SCA022436R7910 0.03
1 NC OA3G01AU 1SCA022819R5260 0.03

Mounting frames for auxiliary contacts of OS20F_…40F_ (OS Mini)


Amount of auxiliary Weight/unit
Description contacts [pcs] Type Order number [kg]
Frame for auxiliary contacts OA1G10 and OA3G01 and for fuse monitor
Mounting on the left side max. 6 OSZ4 1SCA022530R0200 0.06
of the switch

Function chart, change over contacts OA4B1C / OS Mini


Handle position Aux./Test
Main contacts contacts N.O.
Test open closed
0 open open
I closed closed
7 7 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual operated switch fuses 32…1250 A
Ordering information for auxiliary contacts


Auxiliary contact blocks for OS/OSM32G...1250
Types _AU have gold plated contacts for harsh environments and low operating voltages.

OA3G01 Suitable Protection Weight/unit


for switches Description degree Type Order number [kg]
OS/OSM32G...1250 1NO IP20 OA1G10 1SCA022353R4970 0.03
OS/OSM32G...1250 1NC IP20 OA3G01 1SCA022456R7410 0.03
OS/OSM32G...1250 1NO IP20 OA1G10AU 1SCA022436R7910 0.03
OS/OSM32G...1250 1NC IP20 OA3G01AU 1SCA022819R5260 0.03


OA3G01AU
Mounting under the mechanism cover
The “test” contacts operate in ON- and OFF-positions as well as when the handle is turned to
TEST-position = 45 degrees over the OFF-position. The “test tindication” contacts operate only
when the handle is turned to TEST-position. See the function table below. The OA1G10 (N.O.)
or OA3G01 (N.C.) auxiliary contact blocks can be used as standard auxiliary contacts, “test” or
“test indication” contacts. The desired functions are achieved when an auxiliary contact block is
installed in a specific place shown in the mounting instruction. In order to activate the “test” and
“test indication” features, a handle with test function is required. See the optional handles, pages
71-74.

Function table of OS/OSM32G…1250 auxiliary contacts


Handle position Main contacts Aux./Test contacts N.O. Test indication contacts N.O
Test open closed closed
0 open open open
I closed closed open
Maximum number of contact blocks, “Aux./test” contacts and “test indication” contacts, see the table below.
Standard versions include all except for N3-types, which are equipped with integrated neutral through the mechanism.

Maximum number of auxiliary contacts under the mechanism cover


OS/OSM32G…250 OS/OSM315…800 OS/OSM1200…1250
Pole version Standard N3 Standard N3 Standard N3
Maximum number of contact blocks 4 0 8 4 12 8
Aux./Test contacts 4 0 4 2 81) 62)
Test indication contacts 2 0 4 2 4 2
For contact timing, see page 81.
1)
6 aux/test contacts and 2 early operation aux./test contacts.
2)
4 aux/test contacts and 2 early operation aux./test contacts.


Mounting on the left side of the OS switch fuse:
Maximum 8 auxiliary contact blocks (N.O. or N.C.) with the OEA28 module. Side operated types:
OS_S30..._S40 types only.


Mounting on the right side of the OSM motorized switch fuse:
Maximum 4 auxiliary contact blocks (N.O. or N.C.), snap-on mounting


Mounting plate for auxiliary contacts
Mount on the switch mechanism, max. 3 auxiliary contacts.

Suitable for switches Type Order number


R: Mounting on the right side of the switch
L: mounting on the left side of the switch

0S100G_...200G_ OEA30R 1SCA131817R1001

OS100G_...200G_ OEA30L 1SCA131816R1001


SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 78


Accessories for manual operated switch fuses 32…1250 A
Technical information for auxiliary contacts


Module for auxiliary contacts for OS32...1250

Description Type Order number Weight/unit [kg]


Screw mounting to the left side of the switch OEA28 1SCA022714R8810 0.04
OEA28

Performance data for auxiliary contacts according to IEC 60947-5-1

OA1G_, OA3G_
Ui/[V] 690
Uimp/[kV] 4
Pollution degree 3

04
Ith/[A] 16
Cable size 1...2 x 0,75...2.5m2
Maximum fuse 16 A/gG
NEMA A600,R300
Wire size 18 - 14AWG, 1 (2)

OA1G_, OA3G_
AC15 DC12 DC13
Ue /[V] Ie/[A] Ue/[V] Ie/[A] P/[W] Ie/[A] P/[W]
230 6 24 10 240 2 48
400 4 72 4 288 0.8 58
690 2 125 2 250 0.55 69
250 0.55 138 0.27 68
440 0.1 44

OA4_
EN61058-1
Ui/[V] 400
lth/[A] 10
l8 400V AC
10 (4) A, 10E3
6 (2,5) A, 50E3
NEMA 10 A, 125-250V AC, 1/4 HP
M3 Screw connection

MCB_
IEC60947-5-1
Ui/[V] 690
lth/[A] 10
AC12 AC15 DC13
le/[A] 24V 10 8 5
110V 10 8 11
220/240V 10 6 0,55
250V 4 0,55
380/415V 4
660/690V 2
NEMA A600, 10A,
600VAC
79 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for switch fuses OS Mini 20...40A
Technical information for auxiliary contacts

ON
Handle indications and functions

–– The handle indicates the position of the contacts with


complete reliability in all situations. If the contacts are
welded together, the handle doesn´t reach the OFF-position
but remains between ON and OFF, maintaining the door
interlock and padlocking is not possible to do.

–– When operating the switch fuse to the Test-position with a


OFF
test handle the test auxiliary contacts change position. The
main contacts remain open.

Test

ON and OFF-functions of main and auxiliary contacts

Example -45˚ 0˚ 30˚ 60˚ 90˚ α

Main contacts close


Places of auxiliary open
2 NO auxiliary contact close
contacts and Test ind. 1 open
NC auxiliary contact open
close
1
NO auxiliary contact close
2 open
NC auxiliary contact open
close

Test OFF ON
O I

OS Mini
-45˚ 0˚ 30˚ 60˚ 90˚ α

Main contacts
OA4B1C, 1 NO-NC Change NO auxiliary contact
over NC auxiliary contact
contacts
OA1G10, 1NO NO auxiliary contact
OA3G01, 1NC NC auxiliary contact

Test OFF ON
O I

0˚ 30˚ 60˚ 90˚ α

Main contacts O I
O I
MCB-10 + OESAZX169, 1NO NO auxiliary contact
MCB-01 + OESAZX169, 1NC
NC auxiliary contact

OFF ON
O I

OS30...63
-45˚ 0˚ 30˚ 60˚ 90˚ α

Main contacts
OA1G10, 1NO NO auxiliary contact
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 80


Accessories for manual operated switch fuses 32…1250 A
Technical information for auxiliary contacts

ON- and OFF-functions of main and auxiliary contacts

OS/OSM32G...1250 -45˚ 0˚ 30˚ 60˚ 90˚ α


Main contacts O I
O I
OA1G10, 1NO
OA3G01, 1NC NO test contacts O I
inside the mecha- O I
OS_, OSM

OA1G10, 1NO NO early operation O I


test contacts inside O I

04
OA3G01, 1NC the mechanism 1)
+ OEA28 NC test contacts O I
OS_
inside the mechanism O I

OA1G10, 1NO NC early operation O I


test contacts inside O I
OA3G01, 1NC the mechanism1)
OSM_

NO test indication O I
contacts inside the O I
mechanism

NC test indication O I
contacts inside the O I
mechanism

NO auxiliary O I
contacts in the O I
module on the side
NC auxiliary contacts O I
in the module on the O I
S07188A

side of the switch2)


Test OFF ON
O I
1)
OS/OSM1200...1250 only
2)
Also OSM32G...1250 mounted on the right side of the switch
81 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual operated switch fuses 32…1250 A
Ordering information for fourth poles


Fourth poles
Snap-on mounting to the side of the switch (not suitable for motorized OSM-types).

Suitable for Mounting Weight/unit


3-pole switches side Type Order number [kg]
Fusible 4. poles
OSP200-400D OS100GB...160GB Left/right OSP160GB 1SCA114769R1001 0.45
OS125GD...160GD Left/right OSP160GD 1SCA114768R1001 0.45
OS200B Left/right OSP200B 1SCA022735R9180 1.20
OS200D Left/right OSP200D 1SCA022735R8960 1.20
OS250B Left/right OSP250B 1SCA022770R4030 1.20
OS250D Left/right OSP250D 1SCA022735R9340 1.20
OS315B…400B Left/right OSP400B 1SCA022770R3140 2.00
OS400D Left/right OSP400D 1SCA022770R3220 2.00
OS630...800D Left/right OSP800D 1SCA100433R1001 4.20
OS630...800B Left/right OSP800B 1SCA100434R1001 4.20
OSP160GN OS1250D Left/right OSP1250D 1SCA107946R1001 7.20
OS1250DA Left/right OSP1250DA 1SCA112402R1001 7.20
OS1250B Left/right OSP1250B 1SCA107950R1001 7.20
Switched 4. poles
OS100G...160G Left/right OSP160GN 1SCA114770R1001 0.45
OS200_ Left/right OSP200N 1SCA022735R8700 1.20
OS250_ Left/right OSP250N 1SCA022735R9260 1.20
OS400_ Left/right OSP400N 1SCA022770R3490 1.20
OS630...800 Left/right OSP800N 1SCA100432R1001 4.40
OS1200...1250 Left/right OSP1250N 1SCA107943R1001 7.20

OSP250N

OSP800N
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 82


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for neutral links


Neutral links

For OS/OSM 32G...160G


Detachable, mounting onto the base plate or DIN-rail.
OSZ1
H/W/D Mounting Weight/unit
Max. wire [mm] holes Type Order number [kg]
16 mm2 Cu 39/41/40 ø 4.2, distance 32 OSZ1 1SCA022481R3710 0.06
35 mm2 Cu 39/44/45 ø 4.2, distance 35 OSZ2 1SCA022481R3800 0.07

For OS/OSM 100G...1250

04
Mounting with screws (included) onto either side of the switch (OXN250 to OS200...250) or on the
base plate (OXN250...1250) according the table below.

OXN250
Suitable Weight/unit
for switches Type Order number [kg]
Detachable, mounting on the switch
OS200...250 OXN250 1SCA022752R9950 0.40
Detachable, mounting on the base plate
OS/OSM32G...250 OXN250 1SCA022752R9950 0.40
OS/OSM315…400 OXN400 1SCA022770R3060 0.70
OS/OSM630…800 OXN800S 1SCA022831R4880 1.20
OS/OSM1250 OXN1250S 1SCA104163R1001 2.50
OXN400

OXN800S
83 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for handle and spare fuse storage clip


Solid links

Suitable Weight/unit
for switches Type Order number [kg]
OS32GD...OS160GD OFAW00 1SCA022003R9680 0.08
OS200…250B, J OEZNL1 1SCA022723R7400 0.19
OTVS1
OS600J, 800…1200L OEZNL8 1SCA113998R1001 0.58
OS1250B OEZNL10 1SCA116437R1001 0.60
OS250 D OFAW1 1SCA022003R9760 0.15
OS400 D OFAW2 1SCA022003R9840 0.24
OS630/800 D OFAW3 1SCA022003R9920 0.28
OS1250 D OFAW4 1SCA022842R5440 0.665
OS1250 D OFAW4a 1SCA148430R1001 0.665


OTVS2 Handle and spare fuse storage clip for OSM
Handle and two spare fuses (for motor operator) can be stored on the OTVS_. OTVS_ can be ins-
talled on the left side of the motorized switch-fuse OSM_. Snap-on mounting, no tools required.
On OSM1250, the size of the handle prevents the installation onto the switch frame. However, the
handle clip can be separately installed on the panel frame and the fuse holder clip onto the switch
frame.

Suitable Weight/unit
PB200 high for switches Type Order number [kg]
OSM32G...250 OTVS1 1SCA111413R1001 0.02
OSM315...1250 OTVS2 1SCA111414R1001 0.04


Phase barriers
The phase barriers designed for ABB Tmax T4-T5 MCCB’s can also be used for OS200…400 switch
fuses. 3-pole switch fuses need 4 barriers and 4-pole switch fuses need 6 barriers for full protec-
tion. Cutting width of the phase barrier 55mm.

Suitable No. of Height Units/type


for switches poles h[mm] Type Order number [pcs]
OS100G…OS200G 3 - OSB160/4 1SCA131820R1001 4
OS100G…OS200G 3 - OSB160/6 1SCA131821R1001 6
OS250 3 - OSB250/4 1SCA131822R1001 4
OS250 4 - OSB250/6 1SCA131823R1001 6
OS315, OS400 3 200 PB200 high 1SDA054972R1 4
OS315, OS400 4 200 PB200 high 1SDA054973R1 6
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 84


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for terminal shrouds


Terminal shrouds

Suitable Units/type Weight/


for switches Description Type Order number [pcs] unit [kg]
OSS200G1L
Pack of single pole terminal shrouds
Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.
OS/OSM100G…160G Long type OSS160GG1L/3 1SCA114764R1001 3 0.08
OS/OSM100G…160G Short type OSS160GG1S/3 1SCA114766R1001 3 0.05
OS/OSM100G…160G Long type OSS160GG1L/4 1SCA114765R1001 4 0.11
OSS200G1S
OS/OSM100G…160G Short type OSS160GG1S/4 1SCA114767R1001 4 0.07
OS/OSM200 Long type OSS200G1L/3 1SCA022731R8910 3 0.09

04
OS/OSM200 Short type OSS200G1S/3 1SCA022732R0130 3 0.06
OS/OSM200 Long type OSS200G1L/4 1SCA022731R9040 4 0.12
OS/OSM200 Short type OSS200G1S/4 1SCA022732R0050 4 0.08
OS/OSM250 Long type OSS250G1L/3 1SCA022731R9390 3 0.09
OSS250G1L OS/OSM250 Short type OSS250G1S/3 1SCA022731R9550 3 0.06
OS/OSM250 Long type OSS250G1L/4 1SCA022731R9470 4 0.12
OS/OSM250 Short type OSS250G1S/4 1SCA022731R9630 4 0.08
OS/OSM315...400 Long type OSS400G1L/3 1SCA022776R6650 3 0.18
OS/OSM315...400 Short type OSS400G1S/3 1SCA022776R6900 3 0.10
OS/OSM315...400 Long type OSS400G1L/4 1SCA022776R6730 4 0.25
OSS800G1L OS/OSM315...400 Short type OSS400G1S/4 1SCA022776R7030 4 0.15
OS/OSM600...800 Long type OSS800G1L/3 1SCA022776R7200 3 0.53
OS/OSM600...800 Short type OSS800G1S/3 1SCA022776R7540 3 0.21
OS/OSM600...800 Long type OSS800G1L/4 1SCA022776R7380 4 0.70
OS/OSM600...800 Short type OSS800G1S/4 1SCA022776R7460 4 0.28
OSS800G1S OS1200...1250/ OSM1250 Long type OSS1250G1L/3 1SCA107938R1001 3 0.76
OS1200...1250/ OSM1250 Short type OSS1250G1S/3 1SCA107939R1001 3 0.40
OS1200...1250/ OSM1250 Long type OSS1250G1L/4 1SCA107940R1001 4 1.00
OS1200...1250/ OSM1250 Short type OSS1250G1S/4 1SCA107941R1001 4 0.52
Terminal shrouds suitable for mechanisms with detachable integrated neutral (N3 versions)

OSS250G1SH OS/OSM100G…250_N3_ Long type OTS250G1L 1SCA022715R5340 1 0.03


OS/OSM100G…250_N3_ Short type OTS250G1S 1SCA022715R5260 1 0.02
OS/OSM315…400_N3_ Long type OSS250G1L 1SCA022727R5080 1 0.03
OS/OSM315…400_N3_ Short type OSS250G1S 1SCA022727R4940 1 0.02
OS/OSM630…800_N3_ Long type OTS800G1L 1SCA022776R7710 1 0.10
OS/OSM630…800_N3_ Short type OTS800G1S 1SCA022776R8010 1 0.06
OS1200...1250/OSM1250_N3_ Long type OTS1600G1L 1SCA106134R1001 1 0.20
OS1200...1250/OSM1250_N3_ Short type OTS1600G1S 1SCA102667R1001 1 0.12
Single pole terminal shroud for the fourth pole side terminals (LR-types)
IP20, snap-on mounting, grey plastic.
OS250_LR Short type OSS250G1SH/1 1SCA103500R1001 1 0.003
OS400_LR Short type OSS400G1SH/1 1SCA103503R1001 1 0.003
Please consult us when using OS600J...OS800L with OZXA-800 lugs.
85 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for terminal shrouds


Terminal shrouds:

Three and four pole terminal shrouds for side terminals (LR types)
IP20. Snap-on mounting, grey plastic.

OSS160GG3LS
Suitable No. of Units/ Weight/
for switches poles Remarks Type Order number type [pcs] unit [kg]
OS100G...160G_LR 3 Long type OSS160GG3LS 1SCA121570R1001 1 0.01
OS100G...160G_LR 4 Long type OSS160GG4LS 1SCA121571R1001 1 0.01
OS200…400_ 3 Short type OSS400G3SS 1SCA100390R1001 1 0.01
OS200…400_ 3 Long type OSS400G3LS 1SCA100396R1001 1 0.01
OS200…400_ 4 Left side, short OSS400G4SSL 1SCA100392R1001 1 0.01
OSS400G3LS OS200…400_ 4 Left side, long OSS400G4LSL 1SCA100398R1001 1 0.01
OS200…400_ 4 Right side, short OSS400G4SSR 1SCA100394R1001 1 0.01
OS200…400_ 4 Right side, long OSS400G4LSR 1SCA100400R1001 1 0.01

Single pole shroud for terminal clamps


OEZXU14 Snap-on mounting, transparent plastic, IP 2X.

Suitable Units/ Weight/


for clamps Type Order number type [pcs] unit [kg]
OZXB2, 2L OZXB2K 1SCA022264R0010 3 0.06
OZXB3, 4 OZXB3K 1SCA022264R0440 3 0.18
OZXB5, 6 OZXB4K 1SCA022199R2850 3 0.24
OZXB7, 7L OZXB5K 1SCA022283R8040 3 0.15

Terminal angle for side terminals (LR types)


Terminal angle extension bar for cable connections in upper or lower position. Including terminal
bolts M10x30.

Suitable Units/ Weight/


for switches Type Order number type [pcs] unit [kg]
OS100G...160G_LR, 3-pole OEZXU68/3 1SCA121380R1001 3
OS100G...160G_LR, 4-pole OEZXU68/4 1SCA121379R1001 4
OS200…400_LR OEZXU14/3 1SCA100361R1001 3 0.24
OS200…400_LR OEZXU14/4 1SCA101082R1001 4 0.32
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 86


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for terminal clamp sets


Terminal clamp sets

Suitable Units/ Weight/


for switches Cable cross section [mm2] Type Order number type [pcs] unit [kg]
OZXT1
Insulated versions
OS/OSM32G…63G 16…50 Al, 2.5…50 Cu OZXT1 1SCA022469R6310 3 0.05

OZXB-type Al/Cu connectors made of stainless steel

Suitable Cable cross Suitable Units/ Weight/


for switches section [mm2] shroud Type Order number type [pcs] unit [kg]
OZXB8 OS/OSM100G...160G1) 10...70 OSS160G_ OZXB1L 1SCA022169R2030 3 0.15

04
OS/OSM100G...160G 1)
95...185 OSS160G_ OZXB8 1SCA022744R1510 3 0.50

OS/OSM200 10...70 OSS200_L OZXB1L 1SCA022169R2030 3 0.15

OS/OSM200 25...120 OZXB2K OZXB2 1SCA022119R7610 3 0.34

OS/OSM2002) 25...120 OZXB2K OZXB2L 1SCA022158R7750 3 0.42

OZXB2L OS/OSM200 95...185 OSS200_L OZXB8 1SCA022744R1510 3 0.50

OS200 95...240 OSS200_L OZXB9 1SCA022750R3210 3 0.50

OSM250 10...70 OSS200_L OZXB1L 1SCA022169R2030 3 0.15

OS/OSM2502) 25..120 OZXB2K OZXB2L 1SCA022158R7750 3 0.42

OS/OSM2502) 95...185 OZXB3K OZXB3 1SCA022136R8100 3 1.30

OS/OSM250 2)
2x(95...185) OZXB3K OZXB4 1SCA022137R4760 3 1.70
OZXB17
OS/OSM2502) 120...300 OZXB4K OZXB5 1SCA022137R2470 3 2.30

OS/OSM250 2)
120...240 OZXB5K OZXB7L 1SCA022185R7130 3 1.20

OS/OSM2502) 95...185 OSS250_L OZXB8 1SCA022744R1510 3 0.50

OS250 2)
95...240 OSS250_L OZXB9 1SCA022750R3210 3 0.50

OS200...400_LR_ 95...240 OSS400G4LSL OZXB17 1SCA022859R3230 3 0.53


1)
Suitable for OS125G...160G_LR -types only with terminal angle OEZXU68.
2)
Suitable for OS250_BB -types, OS200B_LR, for OS250_LR types suitable only with terminal angle OEZXU14.
87 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for terminal clamp sets


Terminal clamp sets

Suitable Units/ Weight/


for switches Cable cross section [mm2] Type Order number type [pcs] unit [kg]
OZXB2L
OZXB-type Al/Cu connectors made of stainless steel
OS/OSM315...4001) 25...120 OSS400_L OZXB2L 1SCA022158R7750 3 0.42
OS/OSM315...4001) 95...185 OZXB3K OZXB3 1SCA022136R8100 3 1.30
OS/OSM315...4001) 2x(95...185) OZXB3K OZXB4 1SCA022137R4760 3 1.70
OS315...4001) 120...300 OZXB4K OZXB5 1SCA022137R2470 3 2.30
OS315...4001) 2x(120...300) OZXB4K OZXB6 1SCA022137R4920 3 3.03

OZXB8 OS/OSM315...400 1)
120...240 OZXB5K OZXB7 1SCA022185R0040 3 1.00
OS/OSM315...4001) 95...185 OSS400_L OZXB8 1SCCA022744R1510 3 0.50
OS/OSM315...4001) 95...240 OSS400_L OZXB9 1SCA022750R3210 3 0.50
OS/OSM630...800 95...185 OSS800_L OZXB3 1SCA022136R8100 3 1.30
OS/OSM630...800 2x(95...185) OSS800_L OZXB4 1SCA022137R2470 3 1.70
OS/OSM630...800 120...300 OSS800_L OZXB5 1SCA022137R2470 3 2.30
OS/OSM630...800 2x(120...300) OSS800_L OZXB6 1SCA022137R4920 3 3.03
OS/OSM630...800 120...240 OSS800_L OZXB7L 1SCA022185R7130 3 1.20
OS/OSM630...800 95...185 OSS800_L OZXB8 1SCA022744R1510 3 0.50
OS/OSM630...800 95...240 OSS800_L OZXB9 1SCA022750R3210 3 0.50
1)
Suitable for OS315...400_BB_-types, for OS315...400_LR_-types suitable only with terminal angle OEZXU14.
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 88


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for terminal clamp sets


Terminal clamp sets

Suitable Cable cross Suitable Units/ Weight/


for switches section [mm2] shroud Type Order number type [pcs] unit [kg]
OZXB8
OZXR type Al/Cu connectors made of stainless steel
OS/OSM1250 95...185 OTS1600_L OZXB3 1SCA022136R8100 3 1.30
OS/OSM1250 2x(95...185) OTS1600_L OZXB4 1SCA022137R4760 3 1.70
OS/OSM1250 120...300 OTS1600_L OZXB5 1SCA022137R2470 3 2.03
OS/OSM1250 2x(120...300) OTS1600_L OZXB6 1SCA022137R4920 3 3.03
OS/OSM1250 210...240 OTS1600_L OZXB7L 1SCA022185R7130 3 1.20
OS/OSM1250 95...185 OTS1600_L OZXB8 1SCA022744R1510 3 0.50

04
OZXR95 OS/OSM1250 95...240 OTS1600_L OZXB9 1SCA022750R3210 3 0.50
OZXR type Al/Cu connectors made of stainless steel and copper2)
OS100G…160G1) 6…70 OSS160G_L OZXR70 1SCA115529R1001 3 0.15
OS100G…160G1) 25…95 OSS160G_L OZXR95 1SCA115530R1001 3 0.21
OS200 25…95 OSS200_L OZXR95 1SCA115530R1001 3 0.21
OS200 95…185 OSS200_L OZXR185 1SCA115531R1001 3 0.45
OS200 2x(95…185) - OZXR2X185 1SCA115534R1001 3 0.66
OZXR185 OS250 95…185 OSS250_L OZXR185 1SCA115531R1001 3 0.45
OS250 2x(95…185) - OZXR2X185 1SCA115534R1001 3 0.66
OS315…400 95…240 OSS400_L OZXR240 1SCA115532R1001 3 0.42
OS315…400 2x(95…185) - OZXR2X185 1SCA115534R1001 3 0.66
OS315…400 185…300 - OZXR300 1SCA115533R1001 3 0.87
OS630…800 2x(185…300) OSS800_L OZXR2X300 1SCA115535R1001 3 1.59
OZXP type Al/Cu connectors made of tin plated aluminium profile2)
OS100G...160G1) 6...95 OSS160G_L OZXP95 1SCA115539R1001 3 0.09
OZXR240 OS200 6...95 OSS200_L OZXP95 1SCA115539R1001 3 0.09
OS200 16...120 OSS200_L OZXP120 1SCA115540R1001 3 0.15
OS200 25...150 - OZXP150 1SCA115541R1001 3 0.18
OS200 35...240 - OZXP240 1SCA115542R1001 3 0.27
OS250 35...240 - OZXP240 1SCA115542R1001 3 0.27
OS315...400 35...240 - OZXP240 1SCA115542R1001 3 0.27
OS315...400 95...300 - OZXP300 1SCA115543R1001 3 0.42
OZXR300 OS315...400 2x(70...240) - OZXP2X240 1SCA115544R101 3 1.38
OS630...800 2x(70...240) OSS800_L OZXP2X240 1SCA115544R1001 3 1.38
1)
For _LR-types, suitable only with terminal angle OEZXU68.
2)
Suitable also for OS200...400_BB_, for OS200...400_LR_-types suitable only with terminal angle OEZXU14.
89 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual operated switch fuses 32…1250 A
Ordering information for terminal lugs


Terminal lug kits fro Al- and Cu-cables for UL/CSA disconnect switches
One kit includes 6 pcs.

Suitable Tightening torque Weight/ Weight/


for switches Cable size Type [lb.in/Nm] unit [kg] unit [lb]
OS100 AWG14-2/0 OZXA-24 120/13.6 0.21 0.45
OZXA200
OS200 AWG 4-300MCM OZXA-200 275/31.1 0.04 0.09
OS400 AWG2-600MCM OZXA-400 375/42.4 0.05 0.12
OS600...800 2 X AWG 2-600MCM OZXA-800 500/56.5 0.21 0.45
OS1200 4 X AWG 2-600MCM OZXA-1200 500/56.5 0.45 0.98
For ordering please consult us.

Technical data for terminal lugs


Description
OZXA400 UL approval file E60207
Temperature rating, ºC 75
Wire tightening Type of tool Allen (Hex) wrench
Lug mounting Bolt & nut mounting
AWG (American Wire Gauge) wire class B.C

OZXA800

OZXA1200
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 90


Accessories for manual operated switch fuses 32…1250 A
Ordering information for conversion kits


Conversion kits for front operated combination switches

OESAZW2
Suitable Switches Shaft Units/ Weight/
for switches needed [pcs] distance [mm] Type Order number type [pcs] unit [kg]

6 and 8-pole switch mechanism


Parallel attachment for connecting 3- and 4-pole switches. The switches work simultaneously.

6 and 8-pole switches, OS32G...400


The attachment levers are provided with holes, enabling different shaft distances.
The combination switches can be mounted either horizontally or vertically.

04
OS32G...250 Two 3- or 4-pole 45+(0-13)x15 OESAZW2 1SCA022078R1600 1 0.37
OS315...400 Two 3- or 4-pole 60+(0-19)x20 OETLZW9 1SCA022061R3300 1 1.1
OTZW25

Change-over switch mechanism


Two switches connected with a mechanism operating into I-O-II positions.

OS32G...250 Two 3- or 4-pole 210+(0 - 18)x20 OTZW25 1SCA022778R6920 1 2.8


OS315...400 Two 3- or 4-pole 210+(0 - 11)x20 OETLZW11 1SCA022078R0030 1 3.0
OS315...800 Two 3- or 4-pole 210+(0 - 20)x20 OETLZW12 1SCA022078R0200 1 4.6

Bypass switch mechanism


A combination of two switches in parallel with a third switch for change-over operation to bypass,
OTZW26
for example, a breaker for maintenance. The bypass attachment can be used together with ano-
ther combination attachment.

OS32G...250 Three 3- or 4-pole OTZW26 1SCA022778R7060 1 3.3


OETLZW14 Between 1 and 2: 210+(0 - 9)x20
Between 1 and 3: 250+(0 - 9)x20
OS315...800 Three 3- or 4-pole OETLZW13 1SCA022078R0460 1 4.0
Between 1 and 2: 210+(0 - 18)x20
Between 1 and 3: 250+(0 - 18)x20

Mechanical interlock mechanism


Prevents one switch from closing to ON -position, if the other is not in OFF - position.
OTZW/OETLZW-types: When mounted upside down, prevents one switch from opening to OFF-
position, if the other is not in the ON-position. (UPS-usage, make-before-break)

OS32G...250 Two 3- or 4-pole 190 OTZW10 1SCA022431R5280 1 0.40


OS315...800 Two 3- or 4-pole 250 OETLZW14 1SCA022077R3410 1 0.70
OS315...800 Two 3- or 4-pole 300 OETLZW3 1SCA022049R0380 1 0.80
OS315...1250 Two 3- or 4-pole 500 OETLZW15 1SCA022081R9340 1 1.24
91 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE
I II

II I


Accessories for manual operated switch fuses 32…1250 A
Ordering information for conversion kits


I II II
Shafts and handles I
for conversion kits
I II
II I
II I The standard
I II To be Included in the handle or shaft of
ordered conversion kit one of the combined
Conversion separately delivery switches can be used
kit type Shaft Handle Shaft Handle Shaft Handle
6 and 8-pole switches
OESAZW2 - - x (2 pcs) OHB145J12 - -
OETLZW9 - - - - x x
Change-over switches
II I OTZW25 - - x (2 pcs) OHB95J12E011 - -
II I II
OETLZW11 - - x (2 pcs) OHB145J12E011 - -
OETLZW12 - - x (2 pcs) YASDA21 - -
I II Bypass switches
I II I
OTZW26 - - x (3 pcs) OHB95J12E011 - -
OETLZW13 - - x (3 pcs) YASDA 6 - -
III
Change-over switches Mechanical interlock
OTZW10 - - - - x x
OETLZW14 - - - - x x
OETLZW3 - - - - x x
OETLZW15 - - - - x x
II
II

I
I
III
III

Change-over and bypass switches Change-over switches Bypass switches

I II II I III

II ON II ON

O O
OFF OFF

Change-over switches Bypass switches


Change-over switches Bypass switches

I II II I I ONIII I ON
Mechanical
I interlock II II Change-over
I switches
III Bypass switches
II ON II ON
II ON II ON

O O
O
OFF O
OFF
OFF OFF

I ON I ON
I ON I ON
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 92


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for electronic fuse monitor


Electronic fuse monitor
Includes the auxiliary contacts 1NO + 1NC. More information, see brochure OFM_OFS20GB.

OS Mini
Mounting onto the left side of OS Mini (with a frame OSZ4) or on mounting plate.

OFM260 Weight/
Rated voltage [V] Type Order number unit [kg]
120...240/AC OFM240 1SCA022579R1340 0.2
120...260/AC OFM260 1SCA022459R8560 0.14
380...600/AC OFM600 1SCA022579R1260 0.2

04
380...690/AC OFM690 1SCA022459R8480 0.14

OS/OSM32G…1250
Mounting onto the left side of OS32G-1250 switch fuse (right side of OSM motorized switch fuses)
or on DIN-rail or on mounting plate.
OFS260
Weight/
Rated voltage [V] Type Order number unit [kg]
100…260/AC OFS260 1SCA022716R0180 0.16
380…690/AC OFS690 1SCA022715R9920 0.16
45...140/DC OFD110EA 1SCA121775R1001 0.155
135...550/DC OFD500EA 1SCA121776R1001 0.155

OFD500EA Mounting accessories for fuse monitor


Suitable Flat terminal Units/ Weight/
for switches size [mm] Type Order number type [pcs] unit [kg]
Crimp terminals
OS_ 2.8 - 0.8 OFMZX2 1SCA022475R9910 6 0.01
Mounting frame for OS Mini

OFMZX2 Mounting on the left side of the switch OSZ4 1SCA022530R0200 1 0.60

OSZ4
93 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual and motorized switch fuses 32…1250 A
Ordering information for blown fuse indicators


Blown fuse indicators (DPMM)
Striker type fuse is needed. See the dimensions in IEC60269-2-1, Section 1A.

Suitable Weight/
OSD25P3
for switches Type Order number unit [kg]

OS Mini
Auxiliary contact (1x C/O) included. See the ratings on page 78, type OA4

for 3-pole switches OSD25P3 1SCA022192R9060 0.10


for 4-pole switches, fused neutral OSD25P4 1SCA022196R9520 0.10

OSGD50P4 OS/OSM50GF_
Auxiliary contacts (3 x C/O in 3-pole, 4 x C/O in 4-pole) included. Ratings: Ith: 5A, AC15:
0.15A/250VAC. NEMA 5A, 125-250 VAC, 1/10 HP

for 3-pole switches OSGD50P3 1SCA116401R1001 0.015


for 4-pole switches, fused neutral OSGD50P4 1SCA115689R1001 0.020

OSGD125P3 OS/OSM125GF_
Auxiliary contacts (3 x C/O in 3-pole, 4 x C/O in 4-pole) included. Ratings: Ith: 5A, AC15:
0.15A/250VAC. NEMA 5A, 125-250 VAC, 1/10 HP

for 3-pole switches OSGD125P3 1SCA115690R1001 0.025


for 4-pole switches, fused neutral OSGD125P4 1SCA115692R1001 0.035

OSZX3 OS/OSM250D...800D
Auxiliary contacts (3xNO + 3xNC in 3-pole and 4xNO + 4xNC in 4-pole) included. See the ra-
tings on page 78, type OA1G_, OA3G_

for 3-pole switches OSZX3 1SCA101224R1001 0.15


for 4-pole switches, fused neutral OSZX4 1SCA101225R1001 0.20
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 94


Accessories for manual operated switch fuses 32…1250 A
Ordering information for cam attachment and interlocks


Mechanism interlock kits and Electrical interlocks
OS32G…1250 switch fuses can be interlocked in the OFF position using padlocks and by using a
mechanical interlock kit mounted on the mechanism. The diameter of the lock bail can be max 8
mm.

Note: The shaft must go through the interlock into the switch mechanism.

Suitable Weight/
for switches Type Order number unit [kg]
OSZT1A
Interlocking in the OFF position
OS32G...160G OTZT1A 1SCA106522R1001 0.21
OS200 … 250_ OSZT1A 1SCA106532R1001 0.32

04
OS315 … 400_ OSZT2A 1SCA106534R1001 0.75
OS600 …800_ OSZT3A 1SCA106535R1001 1.20
OS1200 … 1250_ OSZT4A 1SCA106536R1001 2.00
Interlocking in the OFF & ON positions
OS32G...160G OTZT1L 1SCA106527R1001 0.21
OS200 … 250_ OSZT1L 1SCA106538R1001 0.32
OS315 … 400_ OSZT2L 1SCA106539R1001 0.75
OS600 …800_ OSZT3L 1SCA106540R1001 1.20
OSZT2A OS1200 … 1250_ OSZT4L 1SCA106541R1001 2.00
95 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for manual operated switch fuses 32…1250 A
Ordering information for coils and mounting accessories


Coils
By installing a coil inside the housing of the interlock kit the switch can be interlocked electrically
in the OFF position or both in the OFF and ON positions. The electrical interlock works using the
PDAL2-230AC50Hz “closed circuit principle”, meaning that when the control voltage is not connected to the coil, the
switches provided with A-type interlocks cannot be turned to the ON position and switches with
L-type interlocks cannot be turned to the ON or OFF positions.

Suitable Weight/
for switches Type Order number unit [kg]
AC coils
24 VAC, 60 Hz PDAL2/24AC60Hz 1SCA111350R1001 0.15
110 VAC, 50Hz PDAL2/110AC50Hz 1SCA106543R1001 0.15
110 VAC, 60Hz PDAL2/110AC60Hz 1SCA107100R1001 0.15
120 VAC, 60 Hz PDAL2/120AC60Hz 1SCA111353R1001 0.15
208 VAC, 60Hz PDAL2/208AC60Hz 1SCA107101R1001 0.15
230 VAC, 50Hz PDAL2/230AC50Hz 1SCA107102R1001 0.15
240 VAC, 60 Hz PDAL2/240AC60Hz 1SCA111356R1001 0.15
OSGZD1
DC coils
24 VDC PDAL2/24DC 1SCA106542R1001 0.15
48 VDC PDAL2/48DC 1SCA107103R1001 0.15
60 VDC PDAL2/60DC 1SCA107104R1001 0.15
110 VDC PDAL2/110DC 1SCA107105R1001 0.15
125 VDC PDAL2/125DC 1SCA111338R1001 0.15
220 VDC PDAL2/220DC 1SCA112503R1001 0.15

Technical data for the coil


Operating voltage U=0.8...1.1 x Un
Operating ambient temperature -40ºC.. 65ºC
Power consumption with AC 6.5 W
with DC 9 VA


Mounting accessories: DIN-rail mounting kit
For mounting a switch fuse into 35 mm DIN-rail

Suitable Weight/
for switches Type Order number unit [kg]
OS32G…160G, 1 - 4 -pole OSGZD1 1SCA115688R1001 0.20
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 96


Accessories for manual operated switch fuses 32…1250 A
Ordering information for spare part kits


Spare part kits

Suitable Units/ Weight/


for switches Type Order number type [pcs] unit [kg]
Fuse cover, window and label set
OS32GB-OS63GB/ OS32GD-OS63GD/OS50GF OSFC1/B10 1SCA149864R1001 10 0,100
OS60GJ OSFC2/B10 1SCA149872R1001 10 0,110
OS125GD-OS160GD/OS125GF OSFC3/B10 1SCA149873R1001 10 0,200
OS100GB-OS200GB OSFC4/B10 1SCA149874R1001 10 0,180
OS100GJ OSFC5/B10 1SCA149875R1001 10 0,180
OS200D/OS200B OSFC6/B10 1SCA149876R1001 10 0,300

04
OS200J OSFC7/B10 1SCA149877R1001 10 0,330
OS250D/OS250B OSFC8/B10 1SCA149878R1001 10 0,400
OS400D OSFC9/B4 1SCA149879R1001 4 0,200
OS315B-OS400B/OS400J OSFC10/B4 1SCA149865R1001 4 0,220
OS630D-OS800D/OS630B-OS800B/OS600J-OS800L OSFC11 1SCA149866R1001 1 0,100
OS1250D/OS1250BOS1200L OSFC12 1SCA149867R1001 1 0,330
Fuse cover and window
OS40FD OSFC13 1SCA149868R1001 1 0,180
Fuse cover
OS20FB/OS32FB OSFC14 1SCA149869R1001 1 0,858
OS25FF/OS32FF OSFC15 1SCA149870R1001 1 0,077
OS30FACC/OS30FAJ OSFC16 1SCA149871R1001 1 0,073
Mechanism cover and label set
OS50GF/OS60GJ/OS63GB-OS160GB/OS63GD-OS160GD OSMC1/B4 1SCA149880R1001 4 0,040
OS200D-250D/OS200-OS250B/OS200J OSMC2/B4 1SCA149881R1001 4 0,045
OS315B-OS400B/OS400D/OS400J OSMC3 1SCA149882R1001 1 0,020
OS630-800BS/OS630-OS800D/OS600J-OS800J OSMC4 1SCA149883R1001 1 0,050
OS1250D/OS1250B/OS1200L OSMC5 1SCA149884R1001 1 0,070
Shaft locking ring and screw
OS32GD-OS250D/OS32GB-OS250B/OS50GF-OS125GF/ OTZS2/B10 1SCA126043R1001 10 0,001
OS60GJ-OS200J
Lock spring and screw
OS400D-OS1250D/OS315B-OS1250B/OS400J-OS1200L OZX1 1SCA105708R1001 10 0,090
97 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 98


Switch fuses
Dimensional drawings
Dimensional drawings
Front operated switch fuses IEC and UL/CSA 99-124
Side operated switch fuses IEC and UL/CSA 125-132
Special connected switch fuses 133-148
Motorized switch fuses 149-155
Accessories for switch fuses 20…1250 A 156-162

05
99 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS Mini

OS16...35FD12_ OS16...35FD22_
OS20...32FB12_ OS20...32FB22_
OS25...32FF12_ OS25...32FF22_

EN 50022 *OS30FA_12_ * OS30FA_12_


14...85 OA 3G01 OA 3G01
30 OA 1G10 OSZ 4 OA4B1C OA 1G10 OSZ 4 OA4B1C
max 3+3 max 1+1 max 3+3 max 1+1
6 38 74
*
* *

I I
35 75...80 75...80
97 O Test
85 O Test

65 * *
*
4,5
93 9 4,5 9 35,6
95 14,3 30,8 27,6 14,3 30,8 27,6
S00579C

105 33 106 33 142


36 45 135...210

41 41
M00224/OS16-35F_ A

IEC 60269-2-1 BS88-2 BS88-6 IEC 60269-2-1 BS88-2 BS88-6


IEC 60260-3-1 IEC 60269-2-1 IEC 60269-2-1 IEC 60269-3-1 IEC 60269-2-1 IEC 60269-2-1
UL 198C OS20FB12A1 OS32FB12F1 OS20FB22A1N1 NFC63210,-63211
CSA C22.2 No.106 OS20FB22A1 OS32FB22F1
OS32FB12A1 OS32FB22A1N1 UL 198C OS32FB22A1
NFC63210,-63211 OS32FB12A2 OS20FB22A1F OS32FB22A2N1 OS32FB22A2
OS25FF1210 OS32FB22A1F OS32FB22F1N1
OS32FF1214 OS25FF2210F OS25FF2210N1
OS30FA12J OS32FF2214F OS32FF2214N1
OS30FA12CC OS16FD2201F OS16FD2201N1
OS16FD1201 OS35FD2202F OS35FD2202N1
OS35FD1202 OS30FAJ22F
OS30FACC22F
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 100


Front operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS40 Mini (IEC Only)

OS 40 FD12000 OS 40 FD22000_

EN 50022
14...133 OA 3G01 OA 3G01
30 OA 1G10 OSZ 4 OA4B1C OA 1G10 OSZ 4 OA4B1C
max 3+3 max 1+1 max 3+3 max 1+1
6A 38 74

Ø66 I
75...80
I
75...80
35
97 O Test
85 O Test

65
A,5
95 9 4,5 9
121 14,3 30,8 27,6 14,3 30,8 27,6
133 33 106 33 142
36 45 135...210

41 41

05
M00223/OS40F_ A

DIN 000 DIN 000


OS40FD12000 OS40FD22000N1
101 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

OS32...63G_P
Mechanism at the end of the switch fuse

mm 47,5
mm mm 47,5 47,5 in 1,87
in in 1,87 1,87
17,5 138...205 (OXP 17,5 (OXP 6x161)
138...205
6x161)
138...205 (O
17,5 45 45
0,69 0,69 0,69
5,43...8,075,43...8,07 1,77 1,77 5,43...8,07
10 10
0,39 0,39 25
0,98
57/2,2457/2,24 57/2,24
6 6 100/3,94 100/3,94114 114 84
ON

0,24
ON ON

0,24
ON

OFF
ON
4,49

OFF
4,49 3,31
O

112/4,41 112/4,41
OFF

O
OFF

T
T

112/4,41
O

OFF
O
T O
T
100/3,94
100/3,94
T
45/1,77
100/3,94 45/1,77
A1
A1

M5 C 14 min
3/16 M5D D C 0,55 14 min
3/16 0,55M5 C 14 min
A D
A B 3/16 0,55
8 B
0,31 8 A B
0,31
29 8
1,14
10 29 0,31
0,39 1,14 25
7 0,98 29
0,28 7 1,14
0/3,94 0,28
114 ON

84
ON

7
OFF

OFF

4,49 O

3,31
O

0,28
T T

7
A1 B1

OS32-63GD OS32-63GB/F OS60GJ


[mm] D01 D02 D03 D04 [mm] B/F01 B/F02 B/F03 B/F04 [mm/in] J01 J02 J03
OS32-63GD OS32-63GB/F OS60GJ
A 64,5 88 111,5 135,5 A 64,5 88 111,5 135,5 A 74,5/2,93 109,5/4,31 144,5/5,69 1
[mm] D01 D02 D03 D04 [mm] B/F01 B/F02 B/F03 B/F04 [mm/in] J01 J02
B 120,5 120,5 120,5 120,5 B 108,5 108,5 108,5 108,5 B 118/4,65 118/4,65 118/4,65
OS32-63GDA 64,5 88 111,5 135,5 OS32-63GB/F
A 64,5 88 111,5 135,5 A 74,5/2,93 109,5/4,31
C - 23,5 23,5 23,5 C - 23,5 23,5 23,5 C - 35/1,38 35/1,38
[mm] B D01 120,5
D02 120,5 D04 120,5
D03 B OS32-63GD
120,5 [mm] 108,5 B/F02108,5
B/F01 108,5
B/F03 B/F04 108,5 B OS32-63GB/F
118/4,65 118/4,65
D 40 40 40 40 D 40 40 40 40 D 45,5/1,79 45,5/1,79 45,5/1,79
A E C64,5
30 - 30 111,5
88 23,5 30
135,5 23,5 30 C [mm]64,530
E 23,5 A 30 - D01 88 23,5 D02 23,5
30111,5 135,5
30
D03 23,5
E
D04
36/1,41 C
[mm] B/F01
36/1,41 - 35/1,38
36/1,41
A145 D68,5 40 92 40111,5 40 40
A145 D A
68,5 409264,5 40
111,5 88 40 111,5 135,5
4086/3,39
A151/2,01 D 121/4,76A
45,5/1,79 64,5
45,5/1,79
156/6,14
B 120,5 120,5 120,5 120,5 B 108,5 108,5 108,5 108,5
B175 E 98,5 30 122 30145,5 30 B17530 E B
98,5 30120,5
122 30 120,5
145,5 30 120,5 30116/4,57
B181/3,19 E 151/5,94
120,5 36/1,41
B 36/1,41
108,5
186/7,32
C A145 - 23,5
68,5 23,5 92 23,5 111,5 C A145 -
68,5 23,5 92 23,5 23,5
111,5 A1 51/2,0186/3,39 121/4,76
M00287/OS32-63G_01-04 B C - 23,5 23,5 23,5 C -
D 40
B175 40
98,5 40122 40 145,5 D B175 40
98,5 40 122 40 40
145,5 B181/3,19116/4,57 151/5,94
D 40 40 40 40 D 40
E 30 30
M00287/OS32-63G_01-04 B 30 30 E E 30 30 30 3030 30 30 30 E 30
A1 45 68,5 92 111,5 A1 A145 45 68,568,5 9292 111,5 111,5 A145 68,5
B1 75 98,5 122 145,5 B1 B175 75 98,598,5 122 145,5
122 145,5 B175 98,5
M00287/OS32-63G_01-04 B
M00287/OS32-63G_01-04 B

OS60GJ
B/F04 [mm/in] J01 J02 J03 J04
135,5 A 74,5/2,93 109,5/4,31 144,5/5,69 179,5/7,07
108,5 B 118/4,65 118/4,65 118/4,65 118/4,65
23,5 C - 35/1,38 35/1,38 35/1,38
40 D 45,5/1,79 45,5/1,79 45,5/1,79 45,5/1,79
30 E 36/1,41 36/1,41 36/1,41 36/1,41
A151/2,0186/3,39 121/4,76 156/6,14
B181/3,19116/4,57 151/5,94 186/7,32
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 102


Front operated switch fuses, IEC
Dimensional drawings

Mechanism between the poles

mm mm G 138...205 (OXP 6x161)


in G 138...205 (OXP 6x161) 45 45
in F FE E 5,43...8,07 1,771,77
5,43...8,07
mm G 138...205 (OX
in F E 5,43...8,07
100/3,94
100/3,94
ON
I
ON
112 112
114
I
OFF

4,41 4,41 11
OFF

O O
T T

45/1,77 112
ON
I
45/1,77

OFF
O
T
4,41

D D 14 min
14 min
M5 M5 HCH C 0,350,35
3/16 3/16 A A B BD 14 min
M5 H C 0,35
8 8 3/16 A B
0,31 0,31
29 29A2 B2 8
1,14 1,14 0,31

05
29
/3,94 7 7 1,14
0,28 0,28 ON ON

84
I I

114
OFF

OFF

O O
T T

7
0,28

A1 B1

OS32-63GD OS32-63GB/F
OS32-63GD OS32-63GB/F OS60GJ
[mm] D11 D12 D13 D22 [mm] B/F11 B/F12 B/F13 B/F22
OS32-63GD
[mm] D11 D12 D13 D22OS32-63GB/F
[mm] B/F11 B/F12 B/F13 B/F22 OS60GJ
[mm/in] J11
A 91
[mm] A D11 114,5 138 138 D13
D12 114,5 A OS32-63GD
D22 138[mm]A B/F11114,5
91 B/F12114,5138 B/F13 138
138 B/F22138 OS32-63GB/F
[mm/in] J11
91 138 91 A 112,5/4,43
B A 120,5 91 120,5
B 120,5 120,5 120,5 138
114,5 120,5 120,5 138B120,5A [mm]
108,5 91
B
D11
108,5
108,5 108,5
114,5 D12108,5
108,5
D13
138
108,5
D22
138
108,5 A[mm] B/F11
B112,5/4,43
118/4,65
C - 23,5 - 120,5
23,5 23,5 120,5 23,5 A 91 114,5 138 138 A 91
B C120,5 23,5 120,5C 23,5B C -108,523,5 - 23,5
108,523,523,5 108,523,5 108,5 23,5 B C 118/4,65 -
B 120,5 120,5 120,5 120,5 B 108,5
D C D60 - 6060 23,5
60 6060 23,5 60 23,5D 60C D 60 - 60 60 23,5 60 60
60 23,5 60 23,5 60 C D -
71,5/2,81
C - 23,5 23,5 23,5 C -
E D E30 60 3030 60
30 3030 60 30 60E 30D E 30 60 30 30 3060 30 30 60 30 60 30 D E 71,5/2,81
36/1,41
D 60 60 60 60 D 60
F E F44 30
4444 30
44 44
67,5 30 44 30F 67,5E F 44 30 44 44 4430 4467,5 30 44 3067,5 E F 55,5/2,19
36/1,41
E 30 30 30 30 E 30
G FG74 44 74
74 44
74
74
97,5 44 74 67,5G 97,5F G 74 44 74 74 74
744444 97,5 44 74 67,597,5 F G 55,5/2,19
91,5/3,6
F 44 44 67,5 F 44
G A1 74 70 74 93,5 74 117 97,5A1 117G A1 74 70 7493,5 74 117 97,5117 G A1 91,5/3,6
81,5/3,21
A1 70 93,5 117 117 G 70 93,5
74 117 74 117 74 97,5 G 74
A1 A2 70 35 93,5 35 117 35 117 58,5A1 A2 70 35 93,5 35 117 35 117 58,5 A1 A2 81,5/3,21
40,5/1,59
A2 35 35 35 58,5 A2 A1 35 70
35 35 93,5 58,5 117 117 A1 70
A2 B1 100
35 123,5 35 147 35 147 58,5 A2 A2B1100 35123,5 35 147 3535147 58,5 A2 B1111,5/4,3914
B1 100 123,5 147 147 B1 100 35
123,5 147 35 147 58,5 A2 40,5/1,59 35
OS60GJ B1100 B2123,5 50 147 50 147 50 73,5B1100B2 123,5 50
B1100 123,5
50
147147 147
147
50 73,5 B1 B2 56/2,20
B1111,5/4,39
100 123,5 146,
B2 50 50 50 73,5 B2 50 50 50 73,5
B/F22 [mm/in] J11B2 50
J12 50
J13 J2250 73,5 B2 B2 50 50 5050 5050 73,5
73,5 B2
B2 56/2,20
50
M00288/OS32-63G_11-22 B
M00288/OS32-63G_11 -22 B
138 A 112,5/4,43 148/5,82 182,5/7,19 182,5/7,19
108,5 B 118/4,65M00288/OS32-63G_1
118/4,65 1-22 118/4,65
B 118/4,65 M00288/OS32-63G_11-22 B

23,5 C - 35/1,38 35/1,38 35/1,38


60 D 71,5/2,81 71,5/2,81 71,5/2,81 71,5/2,81
30 E 36/1,41 36/1,41 36/1,41 36/1,41
67,5 F 55,5/2,19 55,5/2,19 55,5/2,19 90,5/3,56
97,5 G 91,5/3,6 91,5/3,6 91,5/3,6 126,5/4,98
117 A1 81,5/3,21 116,5/4,59 151,5/5,96 151,5/5,96
58,5 A2 40,5/1,59 40,5/1,59 40,5/1,59 75,5/2,97
B1111,5/4,39146,5/5,77181,5/7,15 181,5/7,15
73,5 B2 56/2,20 56/2,20 56/2,20 90,5/3,56
103 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

OS32G_K...OS63G_K

47,5
47,5
E 37
17,5 E 37
17,5
10
10
25
57
57 100
ON
100 114
ON ON

84
112
OFF

ON

OFF

OFF
O ON O
O
114
112
OFF

T T

OFF
O
T O T

100 T

100 65
65 A1
A1
M5 C B
M5 C B 165
165
A
A

37
OS32-63G_K OS32-63G_K
OS32-63G_K OS32-63G_K
[mm] 10D01 D02 D03 10
D04 [mm] B/F01 B/F02 B/F03 B/F04
[mm] D01 D02 D03 D04 [mm] B/F01 B/F02 B/F03 B/F04
A 64,5 88 111,5 135,5 A 64,5 88 111,5 135,5
A 64,5 25 88 111,5 135,5 25
A 64,5 88 111,5 135,5
B 40 40 40 40 B 40 40 40 40
B 40 40 40 40 B 40 40 40 40
100 C - 100
C
23,5
-
23,5
23,5
23,5
23,5
C
23,5
-
C
23,5
-
23,5
23,5
23,5
23,5 23,5
E 30 ON
30 30 ON

114 30 ON
E 30 30 ON
30 30
114 84 30 E 84
OFF

E 30 30 30 30 30 30 30
OFF
OFF

OFF

O O O
O

A145 68,5 T
92 111,5 T
T
A145 68,5 92 T
111,5
A145 68,5 92 111,5 A145 68,5 92 111,5
B175 98,5 122 145,5 B175 98,5 122 145,5
B175 98,5 122 145,5 B175 98,5 122 145,5
65
M00389/OS32-63G_01-04K A
M00389/OS32-63G_01-04K A
A1 B1 A1 B1

165

OS32-63G_K OS32-63G_K
[mm] D01 D02 D03 D04 [mm] B/F01 B/F02 B/F03 B/F04
A 64,5 88 111,5 135,5 A 64,5 88 111,5 135,5
B 40 40 40 40 B 40 40 40 40
-63G_K C - 23,5 23,5 23,5 C - 23,5 23,5 23,5
B/F01B/F04 B/F02E B/F03
30 B/F04 30
30 30 E 30 30 30 30
64,5 88 111,5 135,5
135,5 A1 45 68,5 92 111,5 A1 45 68,5 92 111,5
40 40 40 40
40 B1 75 98,5 122 145,5 B1 75 98,5 122 145,5
- 23,5 23,5 23,5
23,5 M00389/OS32-63G_01-04K A
30 30 30 30
30
68,5 92 111,5
98,5 122 145,5
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 104


Front operated switch fuses, IEC
Dimensional drawings

OS100...160G_P
Mechanism at the end of the switch fuse

138...205 (OXP 6x161) 138...205 (OXP 6x161)

33,4 33,4 81 81
95,5 53,3 20 95,5 53,3 20 45 45
17,5 8,5 7,2 17,5 8,5 7,2
38 38
5,5 5,5 2,5 2,5
43 43
10 17,5 10 25 17,5
2,5 24 2,5 24

ON ON
6 C 6 C
114,5
ON ON ON

Back 114,5 114 110 84


ON ON

46
OFF

Back 46 114 110


OFF

OFF
OFF

OFF

OFF
OFF
O O O
O O T T
O
T
O

connection
T T

connection
T T

types: types:
140 140 65 65
M5 M5
138...205 (OXP 6x161) Ø9 Ø9
61)
8...205 (OXP 6x161)
A1 B1 A1 C1 B1

46 35 10 35 14 min
10 14 min
46
81 81 A 20 20
A B B
45 45 45
38 2,5
2,5

10 10 10
17,5 17,5 17,5
25 25 25

05
24
OS100-160G_ OS100-160G_ OS100-200G_ OS100-200G_
6 6 C [mm]6 D/F01 C D/F02 CD/F03 [mm] D/F04
D/F01 [mm]
D/F02 B01 D/F03 B02 D/F04 B03 [mm] B04B01 B02 B03 B04
A 76,5 111,5 ON
146,5 ON
181,5 A 76,5 ON
111,5 ON
146,5 ON
181,5 ON

114 114
A 76,5 110 111,5 110
146,5 84
181,5 A 84
76,5 111,5 146,5 181,5
ON ON ON

114 110 114,5 84 114,5


OFF
OFF

OFF
OFF
OFF

OFF
OFF
OFF

OFF

O O O O O O

B 130 130 130 130 B 114,5 114,5


O O T O
T T T
T T
T
B T
130 130 130 T
130 B 114,5 114,5 114,5 114,5
C 100 100 100 100 C 118 118 118 118
C 100 100 100 100 C 118 118 118 118
A155 90 125 160 A155 90 125 160
65 B170 105
65 140 65 175
A155 90
B170
125
105
160
140 175
A155 90 125 160
B170 105 140 175 B170 105 140 175
C1 85 120 155 190 C1 85 120 155 190
A1 C1 85
A1
120 B1 155 190
B1
C1 C1 85 120
C1
155 190
M00289/OS100-160G_01-04 C
A1 B1 C1
M00289/OS100-160G_01-04 C

4 min 14 min

B
B OS100-160G_ OS100-200G_
[mm] D/F01 D/F02 D/F03 D/F04 [mm] B01 B02 B03 B04
A 76,5 111,5 146,5 181,5 A 76,5 111,5 146,5 181,5
B 130 130 130 130 B 114,5 114,5 114,5 114,5
C 100 100 100 100 C 118 118 118 118
A1 55 92 125 160 E 55 90 125 160

B02 B03 B1
B04 70 105 140 175 A1 70 105 140 175
1,5 B02
146,5
B04 B03
C1
181,5 B04
85 120 155 190 B1 85 120 155 190
4,5 111,5
114,5
181,5 146,5
114,5 181,5
M00289/OS100-160G_01-04 C
118 114,5118
114,5 118
114,5 114,5
125 118160
118 118 118
140 125175 160
120 140155 190
175
120
190 155 190
105 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

Mechanism between the poles

33,4 33,4 138...205 (OXP 6x161) 138...205 (OXP 6x161)

95,5 81 81
95,5 36 36
20 20 45 45
8,5 5,5 8,5 5,5 38 2,5 38 2,5
43 43
20 20 A2 B2A2

7,2 7,2 2,5 24 2,5 24


140 140
6 6 ON ON ON

114,5
ON

114,5 114
ON
110

OFF
114

OFF
OFF
C
O

Back C
O O

Back
OFF

46
OFF

46
T T
T

O O
T T connection connection
types: types:

65 65
A1
M5 M5 Ø9 Ø9
A1 B1

14 min 14 min
10 10
71,5 35 71,5 35
20 20 B B
161)
8...205 (OXP 6x161) D D
A A

81
45
45 45
2,5 38 2,5
A2 A2 B2 B2 C2 B2
20 OS100-160GD/F OS100-160GD/F A2 OS100-160GB C2
OS100-160GB C2
24 [mm] D/F11 D/F12 [mm] D/F13
D/F11 D/F12
D/F22 [mm]D/F13 B11 D/F22 B12 [mm] B11
B13 B12
B22 B13 B22
A 113 148 A 113
183 148
183 A 183 113 183 148 A 113
183 148
183 183 183

6 130 B 130 130 130 130114,5 B 114,5 114,5 114,5 114,5


6
B 130 ON 130
110
ON
130
ON B ON
114,5 ON ON
ON
114,5 ON
114,5 ON

C 114 114C 100 100 110C 100 118 84 110


100 118 C 118 118 118 118
OFF

OFF
OFF

OFF

OFF
OFF

100 100 100 114 100 84 118 118


OFF

OFF
OFF

84
C
O O

C
O O O O

C
O O O
T T T T T T
T T T

D 81 81 D 8181 11681 D 81 81 116 81 D 81


81 81
116 81 116
A190 125 160 A190 125
160 160 A190 160 125 160 A190 125
160 160 160

65 45 A2 45 8045 45 45 80 45 A2 45 45 45 80
65 A2 45
65 45
A1
A2 45 80
B1105 140 A1 175 B1105 140
175 175
B1 A1105 175 140B1
B1 175 B1
C1105B1 175
140 C1 175 175
C1
B2 52,5 52,5 B2 52,5
52,5 52,5
87,5 B2 52,552,5 87,552,5 B2 52,5
52,5 52,5
87,5 52,5 87,5
14 min 14 min
C1 120 155 C1 120
190 155
190 C1 190 120 190 155 C1 120
190 155
190 190 190

C2 60 60 C2 60
60 60
95 C2 60 60 95 60 C2 60
60 60
95 60 95

B B M00290/OS100-160G_11-22 B
M00290/OS100-160G_11-22 B

OS100-160GD/F
[mm] D/F11 D/F12 D/F13 D/F22
A 113 148 183 183
B 130 130 130 130
C 100 100 100 100
A1 90 125 160 160
A2 45 45 45 80
13
B12 B22
B13 B1B22 105 140 175 175
83
148 183
183 183
,5 114,5 B2 52,5 52,5 52,5 87,5
14,5 114,5 114,5
18
118 118118 C1 118 120 155 190 190
81 116
81 81 C2 116 60 60 60 95
60
160 160 M00290/OS100-160G_11-22 B
45 80
45 45 80
75
175 175
,5 87,5
52,5 52,5 87,5
90 190
155 190 190
60 95
60 60 95
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 106


Front operated switch fuses, IEC
Dimensional drawings

OS100G_K...OS160G_K

33,4 81
33,4 81
95,5 53,3 20
95,5 53,3 20
17,5 8,5 7,2 38 37
17,5 5,5 8,5 7,2 2,5 38 37
43 5,5 2,5
43 10 17,5
10

B
B
ON

114,5
ON ON

114 110
OFF

OFF
ON

OFF
O O O

114,5
ON

114 1
T T
OFF

OFF
O O
T
T

140 65
M5 140 65
M5
A1 B1
A1
46 35
46 35 165
165

37
2,5 37 37

10 10 10 17,5 17,5 17,5 25 25 25

05
OS100-160G_K OS100-160G_K
[mm] D/F01 OS100-160G_K
D/F02 D/F03 D/F04 [mm] B01 OS100-160G_K
B02 B03 B04
B BA 76,5
B [mm]
111,5D/F01 146,5D/F02 181,5D/F03
A D/F04
76,5 [mm]
111,5 B01 146,5 B02 181,5 B03 B04
ON ON ON

114 110
ON

84
ON ON

114 110 111,5110 100 146,5


ON ON ON

B 114
100 A 100 76,5 100 B 118 84 A
84181,5 118 76,5 118 111,5 118 146,5 181,5
OFF
OFF

OFF
OFF
OFF

OFF
OFF
OFF

OFF

O O O
O O O O
O O
T T T
T T T T
T T

A1 55 B 90 100 125 100 160 100


A1 100
55 B 90 118 125 118 160 118 118
B1 70 A1 105 55 140 90 175 125
B1 160
70 A1 105 55 140 90 175 125 160
65 65 65
C1 85 B1 120 70 155 105 190 C1
140 85
175 B1 120 70 155 105 190 140 175
C1 85 120 155 190 C1 85 120 155 190
M00390/OS100-160G_01-04K A
A1 A1 A1 B1 B1 B1 C1 C1 C1
M00390/OS100-160G_01-04K A

165

OS100-160G_K OS100-160G_K
[mm] D/F01 D/F02 D/F03 D/F04 [mm] B01 B02 B03 B04
A 76,5 111,5 146,5 181,5 A 76,5 111,5 146,5 181,5
B 100 100 100 100 B 118 118 118 118
A1 55 90 125 160 A1 55 90 125 160
B03 B02B03 B04 B03 B04
B1 B04
70 105 140 175 B1 70 105 140 175
146,5 111,5
146,5 181,5 146,5
181,5 181,5
C1 85 120 155 190 C1 85 120 155 190
118 118118 118 118118 118
125 90125 160 M00390/OS100-160G_01-04K
125160 160 A
140 105140 175 140175 175
155 120155 190 155190 190
107 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

OS200_P and OS250_P


Mechanism at the end of the switch fuse

75 75
OS 200: 43OS 200: 43
OS 2a50: 53
OS 2a50: 53
20 I 20 I OS 200:110/46 40,5
OS 200:110/46 40,5
OS 250:116/46 3 3
20 OS 250:116/46 6
10,5 10,5 20 K K 6
J L L
8,4 J D
33,5 8,6 8,4 D
33,5 8,6
*) 45 8,5
*) 5,5 45 8,5 18
72 0,22 5,5
72 0,22 E
126 C E
126 M C 144 138,5
M 144
65
65
A1 B1
5 *) 14 min A1
M5
*) B 14 min
M5 H
F G 189...254 B
3 *) OS_N3 A H (OXP 6X210)
6 F G 189...254
6 6 *) OS_N3 A (OXP 6X210)
D

45 45 45 8,5 18 26,5
8,5 8,5 18 18 26,526,5
E E E
144144 144 138,5 138,5
138,5 108 108 108
65 65 65

A1 A1 A1 B1 B1 B1 C1 C1 C1
n min 14 min
4 OS200 OS250

B B [mm] D01 B01 D02 B02 D03 B03 D04 B04 [mm] D01/B01 D02/B02 D03/B03 D04/B04

54189...254 A 89,5
OS200 89,5 133 133 176,5 176,5 220 220 A 99,5 153,5
OS250 207,5 261,5
OXP 6X210)
10) B 149
[mm] D01 130 B01149 130
D02 149
B02 130
D03 149
B03 130
D04 B B04154 154
[mm] D01/B01 154
D02/B02 154
D03/B03
OS200
C 198,5
A 89,5198,5 198,5
89,5 198,5
133 198,5
133 198,5
176,5 198,5
176,5 OS250
198,5
220 C
220193 A 193
99,5 193
153,5 193
207,5
D 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5 D 33,5 33,5 33,5 33,5
[mm] BD01 149
B01 130
D02 B02 149D03 130
B03 D04149 B04 130 [mm]149 D01/130 D02/B 154
D03/ D04/ 154 154
E 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5 E 148,5 148,5 148,5 148,5
C 198,5 198,5 198,5 198,5 198,5 198,5 198,5 B01
198,5 B02
C B03
193 B04 193 193
A F 89,5
48,5 89,5
48,5 133 48,5 133 176,5
48,5 176,5
48,5 22048,5 220 48,5 48,5 F 53,5 53,5 53,5 53,5
D 36,5 36,5 36,5 36,5 36,5 36,5 36,5
A 43,5 36,5 153,5
D 33,5 33,5 33,5
B G 149- 130 - 149 43,5 130 43,5
149 43,5
130 14943,5 43,5
130 144,5 G 99,5 - 207,5
54 261,5
54 54
E 144,5 144,5 144,5 144,5 144,5 144,5 144,5 E 148,5 148,5 148,5
H 20 20 20 20 20 20 20 B 20 H 154 25 154 25154 25
154 25
C I 198,5
F 40 198,540 198,5
48,5 48,5 40198,5 48,5
198,5
40
198,5
48,5
40
198,548,5
40
198,5 48,5
40
48,5
40 I
48,5 45 F 45
53,5 45
53,5 45
53,5
G36,5 - 10 C 19343,5 193 193- 193 54
D J 10 36,5 36,5 - 10 36,5 43,536,5
10 43,5
36,5
10 36,543,5
10 36,5 43,5
10 43,5
10 J 11 G 11 11 11 54
K H 8,4 20 8,4 20 8,4 20
8,4 20
8,4 20
8,4 20
8,4 D 8,420 K 33,5 20 H
11,5 33,5 25
33,5
11,5 33,5 25
11,5 11,5 25
E 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5
L I 8,6 40 8,6 40 8,6 408,6 40
8,6 40
8,6 40
8,6 8,640 L 40 4 I 4 45 4 45 4 45
E 148,5 148,5 148,5 148,5
F M J48,5
164,5 48,5
10164,5 48,5 10
164,5 48,5 1048,5
164,5 48,5
10
164,5 48,5 10 48,5 164,5
164,5 10 164,510 M 10162 J 162 11 162 11 162 11
F A1 53,5 8,4
70,5 53,5 53,5 53,511,5
G A1 K60,5- 8,460,5
- 43,58,4104 43,5 104
8,443,5 147,5
8,4
43,5 147,5
43,5 8,4 43,5 191
8,4 191
8,4 K 124,5 11,5 178,5 232,5 11,5
B1 L79,5 8,6 79,5 8,6123 123
8,6 166,5
8,6 166,5
8,6 210
8,6 G 210
8,6 B1 89,5
- 8,6 54
L 143,5 544 197,5
54 4 251,5 4
H 20 20 20 20 20 20 20 20
C1 M96,5 164,596,5 164,5140 140
164,5 183,5
164,5 183,5
164,5 227
164,5 227
164,5 C1 106,5
164,5 M 160,5 162 214,5 162 268,5 162
H 25 25 25 25
I M00008/OS200_250_01_04
A1 40 40
60,5 40
60,5 40 104 40 40
104 40
147,5 40 147,5 191 191 A1 70,5 124,5 178,5
OS250 OS250
H
OS250 I 45 210 45 45 45
J B1 10 79,510 10
79,5 10 123 10 10
123 10
166,5 10 166,5 210 B1 89,5 143,5 197,5
D04 D04 B04 [mm][mm]
B04 B04 [mm]D02/B02
D01/B01
D01/B01 D01/B01 D02/B02
D02/B02 D03/B03 D03/B03
D03/B03D04/B04 D04/B04 D04/B04
C1 96,5 96,5 140 140 183,5 183,5 J 227 11 227 11
C1 11
106,5 11
160,5 214,5
220 220 A K220 8,4 8,4 8,4153,5 8,4 8,4 8,4261,5 8,4 8,4
220 220 A 99,5 A
99,5 99,5
153,5 153,5 207,5207,5 207,5
261,5 261,5
M00008/OS200_250_01_04 H K 11,5 11,5 11,5 11,5
149 149 130 B
130 LB130 154 B1548,6 8,6 154 8,6 154
154
154 8,6
154 154 8,6 154 8,6 154 8,6
154
154 8,6
198,5198,5 C 198,5 L 4 4 4 4
8,5 198,5 MC 193 C193
164,5 193 193 164,5 193
164,5
193 193164,5
193 193 193164,5 193164,5
164,5
193 164,5
6,5 36,5 36,5 D 36,5
D 33,5 D
33,5 33,5 33,5 33,5 33,5 33,5 147,5 33,5 191 M 162 162 162 162
36,5 A1 60,5 60,533,5 10433,5
33,5 104 33,5
147,5 191
4,5 144,5144,5 E 144,5
144,5 E
E 148,5148,5 148,5148,5
148,5 148,5148,5
148,5 148,5
148,5 148,5 148,5 A1 70,5 124,5 178,5 232,5
B1 79,5 79,5 123 123 166,5 166,5 210 210
8,5 48,5 48,5 F
48,5 48,5
F 53,5 F53,5 53,5 53,5
53,5 53,5 53,5
53,5 53,5 53,5
53,5 53,5 B1 89,5 143,5 197,5 251,5
C1 96,5 96,5 140 140 183,5 183,5 227 227
3,5 43,5 43,5 G
43,5 43,5
G -G - 54- 54 54 54
54 54 54
54 54
M00008/OS200 250 01 04 H
C1 106,5 160,5 214,5 268,5
20 20 20 H
20 H 20 25 H 25 25 25
25 25 25
25 25 25
25 25
40 40 40 I
40 I 40 45 I 45 45 45
45 45 45
45 45 45
45 45
10 10 10 J
10 J 10 11 J 11 11 11
11 11 11
11 11 11
11 11
8,4 8,4 8,4 K
8,4 K8,4 11,5 K11,5 11,5 11,5
11,5 11,5 11,5
11,5 11,5 11,5
11,5 11,5
8,6 8,6 8,6 L
8,6 L8,6 4L 4 44 4 44 4 44 4 4
4,5 164,5164,5 M 164,5
164,5 M 162 M162 162 162
162 162 162
162 162 162
162 162
191 191 191 A1 A1
191 191 70,5 A1
70,5 70,5124,5
124,5 124,5178,5
178,5 178,5232,5
232,5 232,5
210 210 210 B1 B1
210 210 89,5 B1
89,5 89,5143,5
143,5 143,5197,5
197,5 197,5251,5
251,5 251,5
227 227 227 C1
227 227106,5106,5
C1 C1 106,5160,5
160,5 160,5214,5
214,5 214,5
268,5268,5 268,5
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 108


Front operated switch fuses, IEC
Dimensional drawings

Mechanism between the poles

20 20
I IK
K K
I
L JL L
J J
20
G I K
) M5
* *) J
L
B2 B2 B2
33,5
)
A2 A2 A2 C2 C2 C2
* A2 B2
C2
72
M M M
144 M
144 144 144 138,5
138,5 138,5 108 108108 108
144 138,5

*) 10,5 *) 10,5
*)
8,6 A1 A1 A1 A1
B1 B1 B1 B1 C1 C1 C1 C1
8,6 8,6 8,6 8,4
8,4 8,4 8,4
N F
N FN F F E
E E H *) OS_N3:
H H H *) OS_N3:
*) OS_N3:
*) OS_N3:

05
OS200 OS250
[mm] D11 B11 D12 B12 D13 B13 D22 B22 [mm] D11 D12 D13 D22
A 149 130 149 130 141 130 149 130 A 154 154 154 154
B 199 199 199 199 199 199 199 199 B 193 193 193 193
C 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5 C 33,5 33,5 33,5 33,5
D 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5 D 148,5 148,5 148,5 148,5
E OS200 92 92 92 92 92 92 135,5 135,5 EOS250 112,5 112,5 112,5 112,5
[mm] D11 B11 D12 B12 D13 B13 D22 B22 [mm] D11 D12 D13 D22
F 43,5 43,5 43,5 43,5 43,5 43,5 43,5 43,5 F 54 54 54 54
A 149 130 149 130 141 130 149 130 A 154 154 154 154
G B 20
199 20199 20 199 20 199 20 199 20 199 20 199 20 199 25
B 25
193 25193 25 193 25 193
0 H C 132
36,5 132
36,5 175,536,3 175,536,5 219 36,5 219 36,5 219 OS250
36,5 219 36,5 HC 152
33,5 152
33,5 152 33,5152 33,5
OS250 OS250
D11 B11 I D D12144,5 B12
144,5 D13
144,5 144,5B13 40144,5 D22 40144,5 B22144,5 40 [mm] 144,5 D11
D 148,5D12 45 148,5 D13 148,5
45 D22148,5
11 B11 B11 D12 D12 B1240 B12 40
D13 D13 40 B13 B13 40 D22 D22 B22 B22 40
[mm] [mm] D11 D11 I ED12 D12 45 D13 D13 45 D22 D22
149 130 E 149 92 130 92 92
141 92
130 92 149 92 130135,5 A 135,5 154 112,5154 112,5 154 112,5 154 161
9 130130 149J149F 13043,5
10
130 141
10 10 130 130
43,5 141 43,5
1043,5 1491014943,5 130 130 A10 43,5
10 43,5 A 1015443,5 154 JF154 15454 11 154 1115454 154 54154
11 11 54
199 199 199 199 199 199 199 199 B 193 193 193 193
9 199 199 199K199G 1998,4
20
199 199
8,4 20 1998,4 20 199 199
8,4 20 1998,4199 20 8,4199 20 B
199 8,4 B20 8,4193 20193 KG193 193 25 19311,5193
11,5 25 11,5 193 2511,5
193 25
36,5 36,5 36,3 132 36,5132 36,5 36,5 36,5 36,5 219 C 33,5 33,5 33,5 260 33,5 260
5 36,536,5 36,3L36,3H 36,58,6
36,5 36,536,58,6175,5
8,6 8,6175,536,58,6
36,5 36,5 219 8,6 219 8,6
36,5 36,5 36,5 C C 8,6 33,5 219 H 152
33,5 L 33,5 33,5 4 33,5 4
206
33,5 33,5 4 33,54
144,5 144,5 I 144,5 40 144,540 144,540 144,5
40 144,5
40 40 144,5 40 D 40 148,5I 148,5
45 148,5
45 45 148,5 45
5 144,5 144,5 144,5 144,5
M 144,5 144,5
165 144,5
165 144,5165144,5 165 144,5
144,5 144,510 144,5
165 165 144,5165D 148,5148,5 148,5
D 165 M 148,5 162148,5162
148,5 148,5
162 148,5162
92 92 J 92 10 92 10 92
10 1092 135,5 10 135,5 10 E 10 112,5J 112,5
11 11112,5 11 161 11
92 43,592 92 43,592N 92K 43,59280 92
8,4 80 92
43,58,4
92 80 8,4
43,5
92 92
80 8,4135,5
43,5
135,5 135,5 135,5
80 8,4 80 8,4 80 8,4 80
43,5
E
43,5
E 112,5
F
112,5
8,4
112,5
NK
54
112,5 90
11,5
112,5
54
112,5 161
9011,5 90 11,590
54
161 54 11,5
5 43,543,5 43,543,5L 43,543,5
8,6 43,5 43,5 43,5 8,643,5 43,5
8,6 147,5 8,6 8,6 43,5 8,6 191F 8,6 54 8,654 L 54 54 4 54 4 23254 4232 54 25 4
20 20 A1 20 104 20 43,5
104 20 147,5 20 191 191 43,5
20 20 F 191 G A1
25 12425 178 54 25
0 20 20 M 20 165 20
165 16520 165 20 165 20 165 G 165 25 165 M 25 162 25 162 25 162 162
132 20 132 A220N 175,5 52 20 52
80 175,580
20 52219
80
20
52 219 52 20 2195
80 80 80
2095,5219 G 95,5
80 H 80
25 152
A2
N
2562206
90
62 25260
90
62
90
11625260
90
2 132 175,5 175,5 219 219 219 219 H 152 206 260 260
40 132 40 175,5
B1 A1 40 175,5123
104 40104 219
123 166,5147,5 219147,540 210219
40 166,5 191 40 21921040 191
210 191 H 210I 152 B1
191 45
A1 206 14345 197260
124 178 45251 232251260 45 232
40 40 40 40 40
0 10 40 10 B240A2 10 61,5 40 61,5
52 10 52 4061,5 10 52 40 521040
61,5 61,540 52 61,5
10
40
40105
52
I
I 105
1095,5 J
45
95,545 B2 A2
11
45
45 45
62 11 71,5 62
71,5 45 71,5 45
62 45 11 116
11 125,5
10 10 B1 10123 10
123 166,5 10 166,5 10 210 10 210 J 210 11210 B1 11 143 11 197 11251 251
0 8,4 10 8,4 C110 8,4 14010 8,4140 10
183,5 8,4 10
183,5 8,4 227 10 8,4
227 10 2278,4 J K
227 11 11,5
C1 11 11,5
160 214 1111,5
268 2681111,5
8,4 8,4 B2 8,461,5 8,4
61,5 8,4
61,5 61,5 8,4 61,5 8,461,5 K 105 11,5105 B211,5 71,5 11,5 71,5 11,571,5 125,5
4 8,6 8,4 8,6 C28,4 8,6 1408,4 8,6 8,4 8,6 8,4 8,6 8,4 8,6 8,4 8,6 K L 11,5 4 11,5 4 11,5 4 11,5
70 70140 70 70
183,5 8,670 227 70 227 113,5 227113,5 4 227 C2 80 80 80 268134 4 268
8,6 8,6 C1 8,6 8,6 183,58,6 8,6 L C1 4 160 4 214 4
6 165 8,6 8,6C2 165 70 8,6
165 M00014/OS200_250_11_22 165 K 70
8,6 165
70 8,6 165
70 8,670 165 8,6
70 L
165113,5 M 113,5 4 162
C2 4 162
80 4
80 162 80 4162 134
165 165 165 165 165 165 165 M 162 162 162 162
5 80 165 80 165 80 165 80 165 80 165 80 165 80 165 80 M N 162 90 162 90 162 90 162 90
80 80 M00014/OS200_250_11_22
80 80 K 80 80 80 N 90 90 90 90
0 104 80 104 80 147,5 80 147,5 80 191 80 191 80 191 80 191 N A1 90 124 90 178 90 232 90232
104 147,5 147,5 191 191 191 191 A1 124 178 232 232
4 52 104 52 147,5 52 147,5 52 191 52 191 52 191 95,5 191 95,5 A1 A2 124 62 178 62 232 62 232 116
52 52 52 52 52 95,5 95,5 A2 62 62 62 116
52 123 52 123 52 166,5 52 166,5 52 210 52 210 95,5 210 95,5 210 A2 B1 62 143 62 197 62251 116251
123 166,5 166,5 210 210 210 210 B1 143 197 251 251
3 61,5 123 61,5166,5 61,5 166,5 61,5 210 61,5 210 61,5 210 105 210 105 B1 B2 143 71,5 19771,5 25171,5 125,5
251
61,5 61,5 61,5 61,5 61,5 105 105 B2 71,5 71,5 71,5 125,5
5 140 61,5 140 61,5 183,5 61,5 183,5 61,5 227 61,5 227 105 227 105 227 B2 C1 71,5 160 71,5 214 71,5268 125,5268
140 183,5 183,5 227 227 227 227 C1 160 214 268 268
0 70 140 70183,5 70 183,5 70 227 70 227 70 227 113,5 227113,5 C1 C2 160 80 214 80 268 80 268134
70 70 70 70 70 113,5 113,5 C2 80 80 80 134
0 70
14/OS200_250_11_22 K 70 70 70 70 113,5 113,5 C2 80 80 80 134
_250_11_22 K
200_250_11_22 K
109 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

OS200_K and OS250_K

75 75
OS200K OS200K
8,5
8,5
8,5 20 K 20 K D 3 D 3 [mm] D01/B01 D02
[mm] D01/B01
M M A1144 A1144
144 144
N N E E A2 60,5
A2 60,5
L L
A1
A1
A1 B1 138,5
B1 138,5
B2 79,5
B2 79,5
C1 C1108 108
72 72 F F
C2 C2
96,5 96,5
126 126 C C
A2
A2
A2 O O
65 65 OS250K OS250K
18
18
18 [mm] [mm]
D01 D01
A1 A1144 144
A2 A2
70,5 70,5
B1
B1 B1 B1
138,5 138,5
B1 H G I H I A A
G B B B2 B2
89,5 89,5
J J
C1 C1108 108
C2 C2
106,5 106,5
B2
B2
B2
26,5
26,5 OS200K OS250K
26,5 OS200_K OS200_K OS250_KOS250_K
[mm] D01/ D02/ D03/ D04/ [mm] D01 D02 D03 D04
[mm] [mm]
D01 D01 B01 D02B02 B02 D03 D03 B03 B03 D04 D04 B04 B04 [mm] D01/B01
B01B01 B02 D02 B03 B04 [mm] D01/B01 D02
A A
154 154130 130 154 154 130 130 154A1 154 130 144 130 154 144 154 144
130
144
130
A A 154 154
C1
C1 A1 B 144
191 144167 144 191 144 167 191 167 191 167 B 191
C1 B 191 167 191 167 191A2 167 70,5 124,5
191 178,5
167 232,5
B 191
C
A2 198,5 198,5
60,5 198,5
104 198,5 191 198,5 198,5 198,5 198,5 198,5 C 193
C 198,5 198,5147,5 198,5 198,5B1 198,5138,5 198,5
138,5 198,5
138,5 C
138,5 193
D 40,5 40,5 40,5 40,5 40,5 40,5 40,5 40,5 D 40,5
D B140,5 138,540,5 138,5 40,5138,5 40,5
138,5 40,5 40,5 40,5 40,5 D 40,5
E 36,5 36,5 36,5 36,5 B2 36,5 89,5 36,5 143,5 36,5197,5 251,5
36,5 E 33,5
C2 E 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5 E 33,5
C2 B2 F 79,5
144,5 123
144,5 166,5144,5 210 144,5 144,5 144,5 108 144,5 108 144,5 F 148,5
C2 F 144,5 144,5 144,5 144,5 144,5C1 144,5 108 144,5 144,5 F 108 148,5
G
C1 48,5 48,5
10848,5 48,5
108 48,5 108 48,5 48,5 48,5 48,5 48,5 G 53,5
G 48,5 108 48,5 48,5C2 48,5106,5 48,5
106,5 48,5
214,5 G
268,5 53,5
H - - 43,5 43,5 43,5 43,5 43,5 43,5 H -
H C2 - 96,5 - 140 43,5183,5 43,5227 43,5 43,5 43,5 43,5 H -
I 20 20 20 20 20 20 20 20 I 25
I 20 20 20 20 20 20 20 20 I 25
J 89,5 89,5 133 133 176,5 176,5 220 220 J 99,5
J 89,5 89,5 133 133 176,5 176,5 220 220 J 99,5
K 40 40 40 40 40 40 40 40 K 45
OS200_K K 40 40 40 40 40OS250_K 40 40 40 K 45
L 10 10 10 10 10 10 10 10 L 11
L 10 10 10 10 10 10 10 10 L 11
[mm] D01 B01 D02 MB02 D03
8,5 B03
8,5 D04 8,5 B04 8,5 [mm] 8,5 D01/ 8,5 D02/ D03/
8,5 D04/
8,5 M 11,5
M 8,5 8,5 8,5 8,5 8,5 8,5 8,5 8,5 M 11,5
N 8,5 8,5 8,5 8,5 8,5 B01 8,5 B02 8,5 B03 B04
8,5 N 4
A 154 130 N 154 8,5130 154 8,5 130 8,5 154 130
8,5 8,5 8,5 8,5 8,5 N 4
O 164,5 164,5 164,5 164,5 164,5 164,5
O 191 164,5 164,5 164,5 164,5 164,5A 164,5 154 164,5154 164,5164,5
154 164,5
O154
O
162
162
B 191 167 167 191 167 191 167
M00080/OS 200_250_01_04K C
B 191 191 191 191
C 198,5 198,5 198,5
M00080/OS 198,5 198,5
200_250_01_04K C 198,5 198,5 198,5
C 193 193 193 193
D 40,5 40,5 40,5 40,5 40,5 40,5 40,5 40,5
D 40,5 40,5 40,5 40,5
E 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5
E 33,5 33,5 33,5 33,5
F 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5
F 148,5 148,5 148,5 148,5
G 48,5 48,5 48,5 48,5 48,5 48,5 48,5 48,5
G 53,5 53,5 53,5 53,5
H - - 43,5 43,5 43,5 43,5 43,5 43,5
H - 54 54 54
I 20 20 20 20 20 20 20 20
I 25 25 25 25
J 89,5 89,5 133 133 176,5 176,5 220 220
J 99,5 153,5 207,5 261,5
K 40 40 40 40 40 40 40 40
K 45 45 45 45
L 10 10 10 10 10 10 10 10
L 11 11 11 11
M 8,5 8,5 8,5 8,5 8,5 8,5 8,5 8,5
M 11,5 11,5 11,5 11,5
N 8,5 8,5 8,5 8,5 8,5 8,5 8,5 8,5
N 4 4 4 4
O 164,5 164,5 164,5 164,5 164,5 164,5 164,5 164,5
M00080/OS 200_250_01_04K C
O 162 162 162 162
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 110


Front operated switch fuses, IEC
Dimensional drawings

OS315_P and OS400_P


Mechanism at the end of the switch fuse

64 64 81 81
2828 58,5
58,5
50,3/125,4 43,5 5
43,5 5
50,3/125,4
11,511,5 10,810,8
7,5 7,5
M5 12 45
12
M5 40
40 45
3/16
3/16
17 26
17 26
82
82
193 C
140 193 C 164
230 159 1
140 164 159
230
95
95
A1 B1
A1 B
min 20
75,5 64 25
B min 20
75,5 A64 25
230...325 (OXP 12Bx 250)
A 230...325 (OXP 12 x 250)

12 12
45 45

05
OS315 OS400
17 17 17 B03 26 26 35 35
[mm] B01 B02 B0426 [mm] B01 B0235 B03 B04 D01 D02 D03 D04
OS315 OS400
A 127 191 255 319 A 127 191 255 319 127 191 255 319
[mm] B01 B02 B03 B04 [mm] B01 B02 B03 B04 D01 D02 D03 D04
C C BC 176 176 176 176 B 176 176 176 176 193 193 193 193
A 127 191 255 319 A 127 191 255 319 127 191 255 319
C 164 194 194
164 194
159 194 C 194 194 194 194 166 166 166 166
B 176164 176 176 159 176159 B 128 176 128 128
176 176 176 193 193 193 193

OS315
C 194 194 194 194OS400C 194 194 194 194 166 166 166 166
95 95 95[mm] B01 B02 B03 B04 [mm] B01/D01 B02/D02 B03/D03 B04/D04
A1OS315
98,5 162,5 226,5 290,5 A198,5OS400
162,5 226,5 290,5
A1 A1
A1 308,5 B03 B1 B1[mm] B1 C1
C1 B03/D03 C1
B1[mm]
116,5 180,5B01 244,5B02 B04B1116,5 B01/D01 244,5
180,5 B02/D02 308,5 B04/D04
C1A198,5134,5
162,5 198,5
226,5 262,5290,5 326,5 C1 134,5 162,5 198,5
A198,5 226,5 262,5 290,5326,5
min 20
B1116,5 180,5 244,5 308,5 B1116,5 180,5 244,5 308,5
C000014 /OS315_400_001_04 A
OS315 C1 134,5 198,5 262,5 OS400 C1
326,5 134,5 198,5 262,5 326,5
12 x 250)
[mm] B01
C000014 B02 B03 A
/OS315_400_001_04 B04 [mm] B01 B02 B03 B04 D01 D02 D03 D04
A 127 191 255 319 A 127 191 255 319 127 191 255 319
B 176 176 176 176 B 176 176 176 176 193 193 193 193
C 194 194 194 194 C 194 194 194 194 166 166 166 166

B02 B03B04 B03 B04D01 B04 D01D02 D01


OS315 D02 D03 D02 D03 D04 D03OS400
D04 D04
191 255319 255 319 127 319
[mm] B02127
B01 127 191 191 255 191B04
B03 255 319 255 319
[mm] 319
B01/ B02/ B03/ B04/
176 176 176 176 176 193 193 193 193 193 193 193 193D01 D02 D03 D04
176 A1 193 98,5 193
162,5 193 290,5
226,5 193
194 194 194 194 194 166 166 166 166 166 166 166 166A1 166 166
98,5 162,5 226,5 290,5
194 B1 166 116,5 166
180,5 244,5 308,5
B1 116,5 180,5 244,5 308,5
C1 134,5 198,5 262,5 326,5
C000014 /OS315_400_001_04 A
C1 134,5 198,5 262,5 326,5
D02
B03/D03 B03/D03 B04/D04
B04/D04 B04/D04
26,5
290,5 290,5
44,5
308,5 308,5
98,5262,5 262,5
326,5 326,5
326,5
111 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

Mechanism between the poles

64 64
58,5 58,5 2,52
2,52
2,30 2,30
43,5 5 43,5 5
25 25
7,5 10,8 7,5 10,8 55,8/130,9 1,7155,8/130,9
0,20 1,71 0,20
0,98 0,30 0,98 0,430,30 0,43 2,20/5,15 2,20/5,15
M5 □ 12 □ 12 45
M5
40 40 45
3/16 3/16 0,47 0,47 1,77
1,57 1,571,77
*) *) A2 A2
B2
5 5
0,20 0,20 B B
193 193 164 159 12
164 15
7,60 7,60 6,46 6,26 5,
6,46 6,2
230 230
9,06 95 95
9,06 3,74 3,74
A1 B1
A1
*) *)
11,5 min 20
11,5 min 20
0,45 0,79
117 64 0,45 0,79
117 64 A
4,61 2,52 A
4,61 2,52 230...325
C *) OS_N3 230...325
D C
D *) OS_N3 9,06...12,80V(OXP 12x250)
9,06...12,80V(OXP 12x250)
□ 12 12
□45 45
45
0,47 0,47
1,77 1,77
1,77

A2 A2 A2 B2 B2 B2 C2 C2 C2
OS315-400 OS400
[mm] B11 OS315-400
B12 B13 B21 B22 [mm] D11 OS400
D12 D13 D21 D22
B A B 176 B [mm] 176 B11 176 B12 176 B13 176B21
A B22
193 [mm]
193 D11 193 D12 193 D13 193 D21 D22
B 164 194 164
A 164 159
194 176 194 176 159
194 194128176
176 159 B 128
166176 A128
166 193 166 193 166 193 166 193 193
C 6,46140 6,46
B 6,46 6,26
140 194 140 194 6,26
204 2045,04
194 6,26 194
C 5,04
194
140 B5,04
140 166 140 166 204 166 204 166 166
C 254 140 318 140 140 204 204 C 254 140 140 254 140 318 204 204
95 95 D 95190 254 318 D 190 318
D 190 254 318 254 318 D 190 254 318 254 318
3,74 3,74 3,74
B1 C1 C1 C1
OS315 OS400
A1 A1 A1 B1 B1
[mm] B11 OS315B12 B21 B22 B13 [mm] B11/D11 OS400B12/D12 B21/D21 B22/D22 B13/D13
A1163 227 [mm] 227 B11 291 B12 291 B21 A1163
B22 B13 227 [mm] 227 B11/D11 291 B12/D12 291 B21/D21 B22/D22 B13/D13
min 20 A2 81,5 A116381,5 227 145,5 227 145,5 291 81,5 A2
291 81,5 A1163 81,5 227 145,5 227145,5 291 81,5 291
0,79 B1181 245 245 81,5 309 81,5 309 145,5 B1181
A2 145,5 81,5 245 A2 245 81,5 309 81,5 309 145,5 145,5 81,5
B2 90,5 B118190,5 245 154,5 245 154,5 309 90,5 B2
309 90,5 B1181 90,5 245 154,5 245154,5 30990,5 309
.325 C1 199 263 90,5 263 90,5 327 154,5 327 154,5
C1 199 263
OS315-400 B2 90,5
OS400 B2 90,5 263 90,5 327 154,5 327 154,5 90,5
250)
0V(OXP 12x250) C2 99,5 C1 99,5 199 163,5 263 163,5 263 99,5 C2
327 327 99,5 C1 99,5 199 163,5 263163,5 26399,5 327 327
[mm] B11 B12 B13 B21 B22 [mm] D11 D12 D13 D21 163,5 D22
C2
C000011/OS315-400_11_22 99,5
B 99,5 163,5 163,5 99,5 C2 99,5 99,5 163,5 99,5
A 176 176 176 176 176 A 193 193 193 193 193
C000011/OS315-400_11_22 B
B 194 194 194 194 194 B 166 166 166 166 166
C 140 140 140 204 204 C 140 140 140 204 204
D 190 254 318 254 318 D 190 254 318 254 318
D13 D21 D22
D12 D13 D13D21 D21D22 D22
193 193 193
193 193 193 193 193 193 193
166 166 166
166 166 OS315
166 166 166 166 166 OS400
140 204 204
140 140 [mm]
140204 B11204
204 B12 204 B21 B22 B13 [mm] B11/ B12/ B13/ B22/ B13/
318 254 318
254 318 A1254
318 163318
254 227 318 227 291 291 D11 D12 D21 D22 D13

A2 81,5 81,5 145,5 145,5 81,5 A1 163 227 227 291 291
B21/D21 B22/D22
B1 B13/D13
181 245 245 309 309 A2 81,5 81,5 145,5 145,5 81,5
12/D12 291
D11 B21/D21 291
B12/D12 B22/D22 B22/D22
B21/D21 B13/D13 B13/D13
B2 90,5 90,5 154,5 154,5 90,5 B1 181 245 245 309 309
227 227145,5 227 291145,5 291 29181,5 291
C1 145,5 B2 90,5 90,5 154,5 154,5 90,5
81,581,5 309 81,5
145,5 309 145,5 199 145,5263
81,5 263
81,5 327 327
C2 30930990,5
99,5 309 99,5 163,5 163,5 99,5 C1 199 263 263 327 327
245 245154,5 245309154,5
90,590,5 263 90,5
154,5 327 154,5 327 154,590,5
154,5
C000011/OS315-400_11_22 B 90,5 C2 99,5 99,5 163,5 163,5 99,5
199 263163,5 263 263163,5 263 32799,5 327 327 327
99,599,5 163,5
99,5 163,5
163,5 163,599,5 99,5
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 112


Front operated switch fuses, IEC
Dimensional drawings

OS315_K and OS400_K

OS315,OS400 OS400
[mm] B01K B02K B03K B04K [mm] D01K D02K D03K D04K

05
A 127 191 255 319 A 127 191 255 319
OS315,OS400 OS400
B 176 176 176 176 B 193 193 193 193
[mm] B01K B02K B03K B04K [mm] D01K D02K D03K D04K
C 194 194 194 194 C 166 166 166 166
D 219A 127
219 219191 219 255 D 319
236 A 236 127 236 191236 255 319
A1 98,5B 176
162,5 226,5176 290,5 176 A1 176
98,5 B162,5 193226,5 193
290,5 193 193
B1 116,5C 194
180,5 244,5194 308,5 194 B1 194
116,5 C180,5 166244,5 166
308,5 166 166
C1 134,5D 198,5
219 262,5219 326,5 219 C1 134,5
219 D198,5 236262,5 326,5
236 236 236
A1
M00081/OS 315-400_01_04K B 98,5 162,5 226,5 290,5 A1 98,5 162,5 226,5 290,5
B1 116,5 180,5 244,5 308,5 B1 116,5 180,5 244,5 308,5
C1 134,5 198,5 262,5 326,5 C1 134,5 198,5 262,5 326,5

OS315,OS400 M00081/OS 315-400_01_04K B OS400


[mm] B01K B02K B03K B04K [mm] D01K D02K D03K D04K
A 127 191 255 319 A 127 191 255 319
B 176 176 176 176 B 193 193 193 193
D02K D03K D04K
D02K
D03K D03K
D04K C D04K 194 194 194 194 C 166 166 166 166
191 255 319
191
255 255 319
193 193319 D 193 219 219 219 219 D 236 236 236 236
193
193 193
193 193
166 166 166
166 166 A1 16698,5 162,5 226,5 290,5 A1 98,5 162,5 226,5 290,5
166
236 236166 236
236
236
162,5 236
226,5236
B1 290,5 236116,5 180,5 244,5 308,5 B1 116,5 180,5 244,5 308,5
162,5
226,5
180,5 244,5226,5 C1 308,5290,5
290,5 134,5 198,5 262,5 326,5 C1 134,5 198,5 262,5 326,5
180,5
244,5
198,5 244,5
308,5
262,5 326,5308,5
M00081/OS 315-400_01_04K B
198,5
262,5 262,5
326,5 326,5
113 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

OS 630_P and OS 800_P


Mechanism at the end of the switch fuse

39 13.5 A 142/67 6
39 13.5 A 142/67
OS_N3
6 6
M8 20 48.4
OS_N3 50
6
M8 20 48.4 12
36.5 50
5 45 36
36.5 12
ON
5 45 36
230 254 266 306 232 223.3 176
ON ON

ON

OFF
OFF OFF

T OFF T T

ON

230 254 266 min 20


306 232 223.3
ON
ON

OFF

145
OFF
T OFF T
T

B C D
min 20
13
145
77.5 88 233
B
256...379 13
95 (OXP 12X280)
A
77.5 88 233
256...379
95 (OXP 12X280)
A

12 12 12

36 36 45
45 45 36OS630-800
[mm] D/B01 D/B02 D/B03 D/B04
A 167 255 343 431
232 384 223.3 176
ON ON

232
232120 223.3
223.3 176 176
ON

B 208 296
ON ON ON ON

ON ON

OFF OFF

OFF T T
OFF OFF OFF
OFF
T T
OFF OFF T T T
T T

C 150OS630-800 238 326 414


minmin
20 20 min 20 D 176[mm] 264
D/B01 352
D/B02 440
D/B03 D/B04
145 145 145 A
M00097/OS600-800_01-04 167
A / KE00041 255 343 431
B B120B B208 C
296 C 384 C
D D D
3 C 150 238 326 414
233 D 176 264 352 440

56...379 M00097/OS600-800_01-04 A / KE00041


XP
80)12X280)

OS630-800
[mm] D/B01 D/B02 D/B03 D/B04
A 167 255 343 431
B 120 208 296 384
C 150 238 326 414
D 176 264 352 440
M00097/OS600-800_01-04 A / KE00041
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 114


Front operated switch fuses, IEC
Dimensional drawings

Mechanism between the poles

OS_N3 39
OS_N3 39 39 39 142/67 142/67
6 6
13.5 13.5 20
6 20
M8 6 48.4
M8 50 48.4
50
12
12
5 45 36
5 45 36
ON

230 254 266 306 232 223.3 176


ON
ON

ON
OFF OFF
OFF T
T T

OFF

T
230 254 266 306 232 OFF
T
ON

223.
min 20
145
min 20
145 B C
13 B
233
77.5 77.5 88 53 13
256...379
102.5 (OXP 12X280) 233
77.5 77.5 88 53
A 256...379
6 (OXP 12X280)
102.5
A
0
12 12 12

05
45 3645 36 36
45OS630-800
[mm] D/B11 D/B12 D/B13 D/B22
A 253 341 429 429
232OS630-800
232 232 223.3 223.3
381 223.3 176 176 176
ON ON ON ON
ON ON
ON ON
ON

B 205 293 381 OFF OFF OFF OFF OFF


OFF
OFF OFF T T T T T
OFF T
T T T

[mm] D/B11 D/B12 D/B13 D/B22


C 235 323 411 411
min 20 min 20 min 20 D A
261 253
349 341
437 429
437 429
145 145 145 B 205 293 381 381
KE00042 / M00100/OS600-800_11-22 A B235 B B C C C D D D
C 323 411 411
13 D 261 349 437 437
233
KE00042 / M00100/OS600-800_11-22 A
256...379
(OXP 12X280)

OS630-800
[mm] D/B11 D/B12 D/B13 D/B22
A 253 341 429 429
B 205 293 381 381
C 235 323 411 411
D 261 349 437 437
KE00042 / M00100/OS600-800_11-22 A
115 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

OS630_K and OS800_K

mm
in mm
in 13,5 142/67
6
39 6 39
1,54 0,24 0,53 13,5 5,60/2,64 0,24 142/67
OS N3 39 1,54 39 6
20 6 0,53 5,60/2,64 0,24
1,54 1,54
M8 OS N3 0,79 0,24 20
48,4
1,91
50
5/16 1,97 48,4
M8 0,79 50
36,5 5/16 1,91 1,97
5 17,5 32,5
1,44 0,69 1,28
36,5 0,20 17,5
230 5
1,44 9,06 0,69
306 0,20
254 23012,05 232 223,3
10 9,06 9,13
306 8,80
266 254 12,05 232
10,47 10 145 9,13
266 5,71
10,47 145 B C
5,71
13 B
0,51
233 56
77,5 88 9,17 2,20
3,05 3,46 13
95 0,51
233 56
3,74 A 77,5 88 9,17 2,20
3,05 3,46
95
3,74 A

OS600-800_
45,5 45,5 45,5
[mm/in] 17,5 17,5 D/B01
17,5 32,5
D/B02 D/B03 32,5 D/B041,79
32,5
0,69 1,79 1,79
A 0,69
0,69167/6,57 255/10,04
1,28 343/13,50
1,28 1,28
431/16,97
OS600-800_
B 120/4,72
[mm/in] 208/8,19
D/B01 296/11,65
D/B02 384/15,12D/B03 D/B04
C 232 232
232150/5,91 223,3 326/12,83
238/9,37 223,3 414/16,30 176
223,3 176 176
9,13 A 9,13 9,13 167/6,57
8,80 8,80255/10,04 343/13,50
6,93 431/16,97
6,93
D 176/6,93 264/10,39 352/13,86 8,80440/17,32 6,93
B 120/4,72 208/8,19 296/11,65 384/15,12
145 145 145M00229/OS600-800_01-04K
C A 150/5,91 238/9,37 326/12,83 414/16,30
5,71 5,71 5,71
D B 176/6,93 264/10,39
C C 352/13,86
C 440/17,32
D D D
B B
M00229/OS600-800_01-04K A
3
51
56
33 23356 56
2,20 9,17
17 2,20 2,20

OS600-800_
[mm/in] D/B01 D/B02 D/B03 D/B04
A 167/6,57 255/10,04 343/13,50 431/16,97
B 120/4,72 208/8,19 296/11,65 384/15,12
C 150/5,91 238/9,37 326/12,83 414/16,30
D 176/6,93 264/10,39 352/13,86 440/17,32
M00229/OS600-800_01-04K A
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 116


Front operated switch fuses, IEC
Dimensional drawings

OS1200...1250_P
Mechanism at the end of the switch fuse

mm 164,5
in 42 mm 6,48 164,5
mm 1,65 in 42 164,5 6,48
in 42 1,65 6,48 108
1,65 110 4,25 110 108
110 4,33
108 4,25
53 50 4,25 4,33
2,01 1,97 53 50 4,33 175
53
M8 50 1,97 6,89 175
2,01 1,97
M8 5/16 *) M8 2,01 175
6,89
93 6,89
58 93
5/16 *) 93 3,66 58
5/16 *)
3,66 58 2,28 3,66
2,28 2,28

346 6 6
28
1,10 28
43
1,69 56
346 13,62 346 6 0,24 12 28
12
43
1,10
13,62 0,24 12 0,24 0,47
1,10 1,69 2,20
13,62 287 0,47 0,47
240 240 240 287 11,30 287
11,30
266 257,5
9,45 9,45 11,30 266 10,47 257,5 266 10,14 210
9,45 min 40 10,47 10,14 10,47 8,27
min 40 min 40
0,79 0,79 0,79
274 274 274
45 10,79 10,79 A1 A1 B1
*) *) 1,77 6 45 6 45 6
10,79 A1
13,5 13,5 *) 1,77
0,24 0,24 1,77
0,53 13,5 12 0,24
22,5 22,5 0,53 0,53 12 12
110 22,5 0,47 54
0,89 0,89 98,5
98,5 50 0,47 54
98,5 110 1,97 110 50 50 132 0,47 54
11 3,88 4,33 0,89
3,88 132 2,13
132 2,13
0,43 11 126,5
4,33
11 3,88 4,33 1,97 1,97 5,20 14
0,555,20 70 14 5,20 14
2,13
294
0,43
4,98 126,5 0,43 126,5 11,57 294 2,760,55 294 70 0,55 70
4,98 A 4,98 11,57 11,57 2,76 2,76
A A 366...475 80

05
*) N3- types 14,41...18,70(OXP 12 X 395) 366...475
3,15 80
366...475 80
*) N3- types *) N3- types 14,41...18,70(OXP 1214,41...18,70(OXP
X 395) 3,15 12 X 395) 3,15

13,5
0,53
13,5 13,5
0,53 0,53
OS1250D/B_

28 43 56
1,10 1,69 2,20

OS1250D/B_
7 OS1250D/B_
266 257,5 210
356
10,47 10,14 8,27 14,02
356 356
14,02 14,02

274 11
10,79 A1 B1 C1 22,5 0,43
0,89
11 11
22,5 22,5 0,43
54 0,43
0,89
2,13 OS1200/1250 0,89
[mm] D/B01 D/B02 D/B03 D/B04
70
A 209 319 429 539
2,76 OS1200/1250
OS1200/1250
OS1200/1250
A1 166 276 386 496
80 [mm]196
[mm]
D/B01 416 D/B02
D/B01
D/B02526 D/B03
D/B02
D/B03 D/B04 D/B04
D/B03 D/B04
B1 [mm] 306 D/B01
5) 3,15 A 209 319 429 539
C1 A 222 332 209 442 319552 429 539
A A1209 319 166429 276539 386 496
A1
M00207/OS1200-1250_01-04 C 166 276 386 496
B1 196 306 416 526
B1 A1 196 166
306 276
416 386 526 496
C1 222 332 442 552
C1 B1 222 332
196 442
306 416552 526
M00207/OS1200-1250_01-04 C
M00207/OS1200-1250_01-04 C
C1 222 332 442 552
13,5
0,53M00207/OS1200-1250_01-04 C
OS1250D/B_

356
14,02

11
22,5 0,43
0,89
117 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, IEC
Dimensional drawings

Mechanism between the poles

mm 164,5 164,5
mm 6,48 6,48
in in
13,5 50 50 110
20 1,97 22,5 13,5
50 50 12 110 12
0,54 20 1,97
0,54 1,97 4,33
22,5 4,33
0,79 0,89
0,79 6 0,8945 1,97 0,476 45 0,47
13,5 0,24 1,77 0,24 1,77
0,53 13,5 175 175
0,53 6,89 6,89
93
*) 3,66 58 93
*) 2,28 3,66 58
M8 2,28
5/16 M8
5/16 11 164,5
mm 0,43 6,48 11 138 153 166
in 0,43 12 5,44 138
6,03 6,5
13,5 50
50 110 0,47 12 5,44
20 0,54346 1,97 22,5 4,33 287 12 0,47
0,79 13,62 0,89 1,97 6 4511,30 0,47
3460,24 1,77 287
13,5 13,62 175 min 40
11,30
0,53 6,89 0,79 266 257,5 21
min 40 10,14 8,
93 10,47
0,79 266
*) 3,66 58 10,47
M8 2,28 274
5/16 11 10,79
0,43 6 138
274
*) 37,5 12 0,24 5,44 6
153 10,79 166
6,03 A1 6,54 B1
1,48
*) 0,47 54 0,24
346 39,5 98,5 110
287 132 37,5 A1
13,62 1,56 3,88 4,33
11,30 5,20 14
1,48 2,13
98,5 0,55 132 54
197 39,5 110
min 40
14
7,76 1,56 3,88 4,33 0,79294 70 266 5,20 257,5
2,13 210
197 11,57 10,47 0,55 10,14 8,27
A 2,76 294 *) N3- types70
7,76 371...480 80 11,57
274 2,76 *) N3- types
A 14,61...18,91 (OXP10,79
12 X 395) 3,15
6 371...480
13,5
80
*) 37,5 0,24 0,53
1,48 14,61...18,91 (OXP
A1 12 X 395) 3,15 B1 13,5
C1
132 54
39,5 98,5 110
5,20 14 0,53
1,56 3,88 4,33 2,13

OS1250D/B_
197 0,55
7,76 294 70
11,57
2,76 *) N3- types

OS1250D/B_
A
371...480 80
14,61...18,91 (OXP 12 X 395) 3,15 13,5 356
0,53 14,02
138 153 166
5,44 6,03 6,54
OS1250D/B_

22,5 11
266 257,5 210 0,89
356 0,43
10,47 10,14 8,27 14,02
22,5 1
274 0,89 0
10,79
A1 B1 C1 22,5 11
54 0,89 0,43
13
70
,76 *) N3- types
80 OS1200/1250
3,15 OS1200/125013,5
[mm] 0,53D/B11 D/B12 D/B13 D/B22
[mm] D/B11 D/B12 D/B13 D/B22
A
A 322 322 432 432 542 542 542 542
A1 276 OS1200/1250 496
386 496
OS1250D/B_

A1 276 386 496 496


B1306 416 [mm]
526 D/B11
526 D/B12 D/B13 D/B22
B1322
OS1200/1250 C1 442 306 A
552 416 526
552322 526
432 542 542
[mm] D/B11 D/B12 D/B13
A1 D/B22 276 386 496 496
C1
M00208/OS1200-1250_11-22322
C 442 552 552
A 322 432 356
542
B1306 542 416 526 526
A1 276 386 14,02
M00208/OS1200-1250_11-22 C
496 496
C1322 442 552 552
B1306 416 526 526
C1322 442 552 M00208/OS1200-1250_11-22 C
552

M00208/OS1200-1250_11-22 C

22,5 11
0,89 0,43
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 118
mm
mm
in 42
in 42
1,65
1,65 164,5
164,5
6,48
6,48
53 50 108
53 50
1,97 110 108
4,25
2,01
M8 2,01 1,97 110
4,33 4,25
4,33 106
M8
5/16
5/16 — *)*) 175
175
6,89
106

6,89 93
346 Front operated switch fuses, IEC
93
3,66 58
3,66 58
2,28
346 2,28
13,62
13,62 Dimensional drawings287 6
240 287
11,30 6
0,24
240
9,45 11,30 0,24
164,5
9,45 400
6,48 400
108 OS1200_K and OS1250_K
4,25
*)
mm 13,5 106
*)
in13,5 mm42
0,53
22,5 in 1,6542 45 6
0,89
22,5 98,5
0,53
1,65 110 50 1,77
45 0,24 164,5
3,88
98,5 4,33 1,97
50 1,77 6 164,5
6,48
0,89
58 11 110 12 0,24 2946,48
66 110,43 3,88
126,5 4,33 1,97 0,47
12
2,28 53 50 0,47 110 11,57108
294108
0,43 4,98
126,5 1,97 50
M8
4,982,01 53
2,01 A1,97
110
4,33 4,25
11,57
4,25
M8 *) N3- types 4,33 106
106
5/165/16 *) A*) *) N3- types 175
4 175
6,89
6,89 93
93
3,66
3,66 58
58
346 346 400 2,28
2,28
13,6213,62
287
287 66
240 240 11,30
11,30 0,24
0,24
9,459,45
400400
28 43 56
1,10 1,69 2,20
28 43 56
1,10 1,69 2,20
7 6
0,24 *) *)13,5
266
10,47
257,5
10,14
210
8,27
13,5 0,53 266 257,5 210
7 294 22,5 22,5 0,53 45
45 10,47
6 10,14 8,27
98,598,5 110110
11,57 0,890,89 50 1,77 6
0,24
501,97 1,77
11 3,883,88 4,33 4,33
1,97 12
12
0,47
0,24
294
11 0,43 126,5 0,47 294 A1
11,57 B1 C1
0,43 126,5
4,98 11,57A1
4,98 A *) N3- types B1 C1
A *) N3- types
13,5
0,53
13,5 13,5
0,53 0,53
13,5

05
0,53

28 43 56
28 43 56 1,10 1,69 2,20
OS1200/1250_ 1,10 1,69 2,20 28 43 56
1,10
356
1,69 426 2,20
[mm/in]
OS1200/1250_ L01 L02 L03 L04 266 257,5 16,77210
10,47 14,02 10,14
4268,27
A
[mm/in] 209 /L01
266 8,23 319 / 12,56
L02 429 / 16,89
257,5 539 / 21,22
L03 L04 210 266 356 257,5 16,77 210
A A1
10,47
166/ /8,23
209 6,54 276/ /12,56
319 10,87 10,14 496 / 19,53
386//16,89
429 15,20 539 / 21,22
8,27 10,47 14,02 10,14 8,27

A1B1 196 / 7,72 306 // 12,05


166 6,54 416/ /10,87
276 16,38 526//15,20
386 20,71 496 / 19,53 A1 37,5 B1 C1
B1C1 196
222/ 7,72
/ 8,74 332/ /12,05
306 13,07 442/ /16,38
416 17,40 552//20,71
526 21,73
11 1,48
22,5 37,5 11
B1 C
C1M00231
222 / 8,74 332 / 13,07 442 / 17,40 552 / 21,73 0,43 A1 0,43
20 1,48
/ OS1200-1250_01-04K A
A1 B1 C1 0,89 11
22,5 0,43 13,511
0,79 0,43
6 0,53
M00231 / OS1200-1250_01-04K A
0,89OS1250D/B_ 20
13,5 0,24
0,79 13,5
OS1250D/B_ 0,53 6 0,53
13,5 OS1200L_
0,24
13,5
0,53 0,53 OS1200L_
13,5
OS1200/1250_
0,53
OS1200/1250_
[mm/in] L01 426
[mm/in] L01 L02L02 L03 L03 L04 L04 356 16,77
A 209 / 8,23 319 / 12,56 429 / 16,89 539 / 21,22
14,02
A
OS1200/1250_ 209/8,23 319/12,56 429/16,89 539/21,22
A1 166 / 6,54 276 / 10,87 386 / 15,20 496 / 19,53 356 426
[mm/in] L01 L02 L03 L04 16,77
A1
B1 196 / 7,72 166/6,54
306 / 12,05 276/10,87
416 / 16,38 526 /386/15,20
20,71 496/19,53 14,02
A 209 / 8,23 319 / 12,56 429 / 16,89 539 / 21,22 37,5
C1 222 / 8,74 332 / 13,07 442 / 17,40 552 / 21,73
A1 B1 166 196/7,72
/ 6,54 276 /306/12,05
10,87 416/16,38
386 / 15,20 496 / 19,53 526/20,71
426 11 1,48
356 22,5 11
B1 196 / 7,72
M00231 306 / 12,05A
/ OS1200-1250_01-04K 416 / 16,38 526 / 20,71 16,77 0,43 0,43
C1 222/8,7414,02 332/13,07 442/17,40 552/21,73 0,89 20 37,5
C1 222 / 8,74 332 / 13,07 442 / 17,40 552 / 21,73
OS1250D/B_ 0,79 1,48
M00231/OS1200-1250_01-04K A 11 6 11
M00231 / OS1200-1250_01-04K A
22,5 0,43 0,24 0,43
0,89 20 OS1200L_
37,5 OS1250D/B_ 0,79
6
11 1,48 0,24
22,5 11
0,43 0,43 OS1200L_
0,89 20
OS1250D/B_ 0,79
6
0,24
OS1200L_
119 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, UL/CSA
Dimensional drawings

OS60GJ_
Mechanism at the end of the switch fuse

mm 53,5 53,5
mm
in in 2.11 2.11
25 25 E E
0.98 0.98
17,5 17,5
0.69 0.69
10 10 138...205 138...205
(OXP 6x161)(OXP 6x161) 45 45
0.39 0.39 5.43...8.075.43...8.07 1.77 1.77

114 29 29
114 57 57 6 1001.14 1.14
4.49 6 100
4.49 2.24 0,24 3.94
2.24
100 0,24 3.94
100 112
3.94 84 112 7
3.94 84 4.41 7
3.31 4.41 45 0.28
3.31 45 0.28
1.77
1.77

D C 14 min
M5 D C 14 min 0.55 min
M5 A1 0.55 min
53,5 A1 B
2.11
A
A B1
B
E
B1
17,5 OS60G_
0.69 OS60G_ [mm/in] J01 J02 J03 J04
10 138...205 (OXP 6x161) 45 [mm/in] AJ01 75/2.95J02 110/4.33J03 145/5.71 J04180/7.09

M00529/ OS60GJ01-04 A
0.39 5.43...8.07 1.77
A 75/2.95
B 110/4.33 118/4.65
118/4.65 145/5.71 118/4.65
180/7.09118/4.65

M00529/ OS60GJ01-04 A
B 118/4.65
C 118/4.65 118/4.65
35/1.38 118/4.65
35/1.38 35/1.38
OS60_G 29 C D 35/1.38 46/1.81
46/1.81 35/1.38 46/1.81
35/1.38 46/1.81
6 100 1.14
[mm/in] J01 J02
0,24 J03 J04 D 46/1.81
E 46/1.81 36/1.42
36/1.42 46/1.81 36/1.42
46/1.81 36/1.42
3.94
112 75/2,95 E A1
36/1.42 51/2.01
36/1.42 86/3.39
36/1.42 121/4.77
36/1.42 156/6.14
A 110/4,33 145/5,71 180/7,09 7
4.41 0.28 A1 B1
51/2.01 81/3.19
86/3.39 116/4.57
121/4.77 151/5.95
156/6.14186/7.33
45
B 118/4,65 118/4,65 118/4,65 118/4,65 B1 81/3.19 116/4.57 151/5.95 186/7.33
1.77
C 196 35/1,38 35/1,38 35/1,38

D C D 46/1,81
14 min 46/1,81 46/1,81 46/1,81 Piirustus No.
Document No. 13/OS60GJ01-04 A
0.55 min Piirustus No.
A1 E 36/1,42 36/1,42 36/1,42 36/1,42 Document No. Teki
13/OS60GJ01-04
2017-04-03 A
A B Prepared
T Joensuu
A1 51/2,01 86/3,39 121/4,77 156/6,14 Teki 2017-04-03
B1 Prepared
T Joensuu
ABB Oy Protection and Connec
B1 81/3,19 116/4,57 151/5,95
OS60G_
186/7,33
[mm/in] J01 J02 J03 J04
ABB Oy Protection and Connection
M00529/ OS60GJ01-04 A
A 75/2.95 110/4.33 145/5.71 180/7.09
M00529/ OS60GJ01-04 A

B 118/4.65 118/4.65 118/4.65 118/4.65


C 35/1.38 35/1.38 35/1.38
D 46/1.81 46/1.81 46/1.81 46/1.81
E 36/1.42 36/1.42 36/1.42 36/1.42
A1 51/2.01 86/3.39 121/4.77 156/6.14
B1 81/3.19 116/4.57 151/5.95 186/7.33

Piirustus No.
Document No. 13/OS60GJ01-04 A
Teki 2017-04-03
Prepared
T Joensuu

ABB Oy Protection and Connection


SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 120


Front operated switch fuses, UL/CSA
Dimensional drawings

Mechanism between the poles

mm G
in mm G
in B2 E 138...205 (OXP6x161) 45
B2 E 138...205 (OXP6x161)
5.43...8.07 1.77 45
F A2 5.43...8.07 1.77
F A2

114 6 29
57
114 6 1.14 29
4.49 57 0,24 100 1.14
100 2.24
4.49 0,24 3.94 100
3.94 100 2.24 112 3.94
3.94 112 7
84 4.41 45 7
84 4.41 45 0.28
3.31 3.31 1.77 0.28
1.77

14 min 14 min
M5 M5 D DC C 0.55 min0.55 min
A1 A1 B B
B1 B1
A A

G
B2 E 138...205 (OXP6x161) 45

05
F A2 5.43...8.07 1.77

29
57 OS60G_ OS60G_ 6 OS60G_ 1.14
2.24 0,24 100
[mm/in] J11 [mm/in] J12
J11
[mm/in] J12
J11J13 J13 J22 J13J22
J12
3.94 J22
112
4.41 A A
112,5/4.43 112,5/4.43
147,5/5.81 147,5/5.81
182,5/7.19 182,5/7.19
182,6/7.19 182,6/7.19
7
A 112,5/4,43 147,5/5,81 182,5/7,19 45182,6/7,19
1 0.28
M00528/ OS60GJ11-22 A
M00528/ OS60GJ11-22 A

B B
118/4.65 118/4.65
118/4.65 118/4.65
118/4.65 118/4.65
1.77 118/4.65 118/4.65
B 118/4,65 C 118/4,65C 118/4,65
35/1.38 118/4,65
35/1.38
35/1.38 35/1.38
35/1.38 35/1.38
D 71,5/2.82 71,5/2.82 71,5/2.82
71,5/2.82 71,5/2.82
C - D 35/1,38
14 min
71,5/2.82 71,5/2.82
35/1,38 71,5/2.82
35/1,38
D C E E
36/1.42 36/1.42
36/1.42 36/1.42
36/1.42 36/1.42
36/1.42 36/1.42
0.55 min
A1 D 71,5/2,82 71,5/2,82
F 71,5/2,82 55,5/2.19
55,5/2.19 71,5/2,82
F B 55,5/2.19 55,5/2.19 55,5/2.19 55,5/2.19
90,5/3.56 90,5/3.56
B1
E 36/1,42 G 36/1,42 G
91,5/3.60 91,5/3.60
36/1,42 91,5/3.60
91,5/3.60 91,5/3.60
36/1,42
91,5/3.60 91,5/3.60 91,5/3.60
A Piirustus No. Piirustus No.
A1 81,5/3.21 Document No.Document No. 13/OS60GJ11-22
13/OS60GJ11-22 A
F 55,5/2,19 A1 55,5/2,19
81,5/3.21 116,5/4.59 116,5/4.59
55,5/2,19 151,5/5.97 151,5/5.97
151,5/5.97 151,5/5.97
90,5/3,56
A2 41/1.61 41/1.61 41/1.61 76/2.99 Teki 2017-04-03
Prepared 2017-04-03
Teki
A2 41/1.61 41/1.61 41/1.61 76/2.99
G 91,5/3,60 91,5/3,60 111,5/4.39
91,5/3,60 91,5/3,60
Prepared
T JoensuuT Joensuu
B1111,5/4.39B1 146,5/5.77181,5/7.15
146,5/5.77181,5/7.15 181,5/7.15 181,5/7.15
B256/2.20 56/2.20 56/2.20 91/3.58
A1 81,5/3,21 B2116,5/4,59
56/2.2056/2.20 151,5/5,97
56/2.20 151,5/5,97
91/3.58 ABB Oy ABB Oy Protection
Protection and Con
OS60G_ A2 41/1,61 41/1,61 41/1,61 76/2,99
[mm/in] J11 J12 J13 J22
A 112,5/4.43
B1
147,5/5.81
111,5/4,39
182,5/7.19182,6/7.19
146,5/5,77 181,5/7,15 181,5/7,15
M00528/ OS60GJ11-22 A

B 118/4.65 118/4.65
B2 118/4.65 118/4.65
56/2,20 56/2,20 56/2,20 91/3,58
C 35/1.38 35/1.38 35/1.38
D 71,5/2.82 M00528/
71,5/2.82 OS60GJ11-22
71,5/2.82 A
71,5/2.82
E 36/1.42 36/1.42 36/1.42 36/1.42
F 55,5/2.19 55,5/2.19 55,5/2.19 90,5/3.56
G 91,5/3.60 91,5/3.60 91,5/3.60 91,5/3.60 Piirustus No.

A1 81,5/3.21 116,5/4.59 151,5/5.97 151,5/5.97


Document No. 13/OS60GJ11-22 A
A2 41/1.61 41/1.61 41/1.61 76/2.99 Teki 2017-04-03
Prepared
T Joensuu
B1111,5/4.39146,5/5.77181,5/7.15181,5/7.15
B256/2.2056/2.20 56/2.20 91/3.58 ABB Oy Protection and Connection
121 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, UL/CSA
Dimensional drawings

OS200J
Mechanism at the end of the switch fuse
75
2,95 75
20 40 2,95
0,79 1,57 20
8,6 40
0,79 1,578,4
110/46
40,5 3
M5 20 0,34 4,33/1,81 110/46
8,6 1,59 0,12 40,5 3
3/16 0,79 M5 20 0,33 0,34 8,4 4,33/1,81
1,596 0,1245
3/16 0,79 0,33 0,24
10,5 36,5 1,77 6 45
0,43 10,5 1,44 36,5 0,24 1,77
*) 0,43 1,44 8,5 18
*) 0,34 8,5 0,71
72 5,5 0,34
2,83 0,22 5,5
72 159
126 2,83 164,5 0,22 144
6,26 159 144 138
4,96 126 6,48 164,5 198,5 6,26 5,67
4,96 6,48
218 7,82 198,5 5,67 5,45
7,82 65
8,59 218 2,56 65
8,59 2,56

8,4/0,33 A1
*) 8,4/0,33 A1
33,5/1,32
33,5/1,32
*) 14 min
10 14 min
8,6/0,34 0,40 10 0,55
48,5 20
8,6/0,3446 48,5 20 0,40 132
0,55
1,91 1,81 46
0,79 5,20 132
1,91 1,81
5 A *) OS_N3:
0,79
189...254
5,20
A *) OS_N3: 189...254
7,44...10 (OXP 6X210)
7,44...10 (OXP 6X210)
3
0,12
6 6 45 6 45 45
0,24 0,24 0,241,77 1,77
1,77

8,5 8,5 8,5 18 18 18 26,5 26,526,5


OS200 0,34 0,340,34 0,71 0,710,71 1,04 1,041,04
OS200
[mm/in] J01 J02 J03 J04
159 159 159
[mm/in] J01 J02 J03 J04
A 89,5 / 3,52 144135,5/5,34
144 144 181,5/7,15 227,5/8,96 108 108 108
6,26 6,26 6,26 A 89,5 / 3,52 135,5/5,34 138,5 138,5
181,5/7,15 227,5/8,96
138,5
A1 60,5 / 2,38 5,67 5,675,67 152,5/6,00 5,45
106,5/4,19 198,5/7,82
5,455,45 198,5/7,82 4,25 4,254,25
A1 60,5 / 2,38 106,5/4,19 152,5/6,00
65 65 65B179,5 / 3,13125,5/4,94171,5/6,75 217,5/8,56
2,56 2,56 B179,5 / 3,13125,5/4,94171,5/6,75 217,5/8,56
2,56
C196,5 / 3,80142,5C1/ 96,5
5,61188,5/7,42
/ 3,80142,5 /234,5/9,23
5,61188,5/7,42 234,5/9,23
M00001/OS200J01_04 H A1 A1 A1 B1 B1 B1 C1 C1 C1
M00001/OS200J01_04 H
min
14 min
14 min
55 0,55
0,55
32 132
20 5,20 132 OS200
5,20
254 [mm/in] J01 J02 J03 J04
X210)
OXP 6X210)
10 (OXP 6X210) A 89,5/3,52 135,5/5,34 181,5/7,15 227,5/8,96
A1 60,5/2,38 106,5/4,19 152,5/6,00 198,5/7,82
B1 79,5/3,13 125,5/4,94 171,5/6,75 217,5/8,56
C1 96,5/3,80 142,5/5,61 188,5/7,42 234,5/9,23
M00001/OS200J01-_04 H
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 122


Front operated switch fuses, UL/CSA
Dimensional drawings

OS400J
Mechanism at the end of the switch fuse
81
3,19
28 58,5 81
1,10 2,30 10,8 43,5 5 3,19
58,5 55,8/130,9
28 0,43 1,71 0,20
11,5 10,8 2,20/5,15 43,5 5
1,10 2,30
7,5 55,8/130,9
M5 0,45 0,30 0,43 12 45
40
2,20/5,15 1,71 0,20
3/16 11,5 7,5 1,56 0,47 1,77
M5 0,45 0,30 12 45
) 40
*3/16 1,56 0,47 1,77 17
5 0,67
82
3,23 *) 0,20
17
193 5 C 0,67
82
140 3,23 7,60 230 0,20 164 15
5,51 193 C
9,06 6,46 6,
140 7,60 230 95 164
5,51 3,74
9,06 6,46
95
*) min 20
3,74 A1
0,79
*) B min 20
75,5 64 25
2,97 2,52 0,98 230...325 (OXP 12x250) 0,79
75,5 64 25 B
9,06...12,80
2,97 A 2,52 *0,98
) OS_N3
230...325 (OXP 12x250)
4512 45 9,06...12,80
A *) OS_N3
1,77
0,47 1,77

05
17 17 17 26 26 26 35 35 35
0,67 0,67 0,67 1,02 1,02 1,02 1,38 1,38 1,38
OS400
C C C
[mm/in] J01 J02 J03 J04
A 164OS400 191/7,52
127/5,00
164 164 159 319/12,56159
255/10,04 159 128
128 128
B 6,46
176/6,93
[mm/in] 176/6,93
J01 J02 6,26 176/6,93
176/6,93
6,46 J036,26 J04 5,04
6,26 5,04 5,04
95
6,46
95 95C 194/7,64
A 194/7,64
127/5,00 194/7,64
191/7,52 194/7,64
255/10,04 319/12,56
3,74 3,74 3,74 B 176/6,93
C000012 /OS315_400_01_04 B 176/6,93 176/6,93 176/6,93
C 194/7,64 194/7,64 194/7,64 194/7,64
A1 A1 B1 B1 C1 C1 C1
min 20 C000012 /OS315_400_01_04 B
A1 B1
0,79

2x250)
80 OS400
[mm/in] J01 J02 J03 J04
A 127/5,00 191/7,52 255/10,04 319/12,56
B 176/6,93 176/6,93 176/6,93 176/6,93
C 194/7,64 194/7,64 194/7,64 194/7,64
C000012 /OS315_400_01_04 B
123 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Front operated switch fuses, UL/CSA
Dimensional drawings

OS600J and OS800L


Mechanism at the end of the switch fuse

39 13,5 142/67 6
0,53 39 5,60/2,64
6
1,54 0,24 0,24
OS_N3 1,54 142/67
20 39 13,5 39 6
M8 0,791,54 6 0,53 48,4 505,60/2,64 0,24
5/16 OS_N3 0,24 1,54 1,91 1,97
20
M8 0,79 48,4 50 12
36,5 5/16 1,91 1,970,47
1,44 5 45 36
0,20 12
36,5 230 1,77 1,42 0,47
1,44 9,06 306 5 45 36
0,20
254 12,05
230 1,77 1,42
10 9,06 306
266 254 12,05
10,47 10 232 223,3
min 20
266 0,79 145 9,13 8,80
10,47 5,71 232
min 20
0,79 145 9,13
5,71
13
0,51 B
233
77,5 88 9,17 13
3,05 3,46 256...379 0,51 B
95 10,08...14,92 (OXP 12X280) 233
77,5 88 9,17
3,74 A 3,05 3,46 256...379
95 10,08...14,92 (OXP 12X280)
3,74 A
12
0,47
36 3645 36
45
,42
77 1,42
1,77 1,42

OS600-800
[mm/in] J/L01
OS600-800 J/L02 J/L03 J/L04
A 232 232 232[mm/in]
167/6,57 223,3
255/10,04223,3 223,3 J/L02 431/16,97J/L03176176 J/L04
J/L01 343/13,50 176
0min 20
145
0,79145 145 B 9,139,13 9,13A 120/4,72 8,80
208/8,19 8,80
167/6,57 8,80
296/11,65 343/13,506,93
255/10,04 384/15,12 6,93 6,93
431/16,97
5,71 5,71 5,71 C B 150/5,91 238/9,37
120/4,72 326/12,83
208/8,19 414/16,30
296/11,65 384/15,12
D C 176/6,93 264/10,39
150/5,91 352/13,86
238/9,37 440/17,32
326/12,83 414/16,30
B B
DB
M00097 / OS 600-800_01-04 B 176/6,93 C
264/10,39 C C
352/13,86 440/17,32 D D D
M00097 / OS 600-800_01-04 B

0)

OS600-800
[mm/in] J/L01 J/L02 J/L03 J/L04
A 167/6,57 255/10,04 343/13,50 431/16,97
B 120/4,72 208/8,19 296/11,65 384/15,12
C 150/5,91 238/9,37 326/12,83 414/16,30
D 176/6,93 264/10,39 352/13,86 440/17,32
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 124


Front operated switch fuses, UL/CSA
Dimensional drawings

OS1200L

164,5
42 164,5 6,48
42 1,65 6,48
1,65 110 108
110 108 4,25
4,33 4,25 4,33
50 53 50 175
53
2,01 1,97
M8 2,01 1,97 175
6,89 6,89
M8
*) 93 93
5/16 5/16
*) 3,66 58 3,66 58
2,28 2,28
28 43 28
6 6 12 1,10 1,69
1,10
346 346 0,24 0,24 12
13,62 164,5 0,47
42
13,62 287 6,48 0,47
1,65 240
240 11,30 287 266
10,47
257,5
266
10,14
9,45 11,30
108 10,47
9,45 110 4,25 min 40
4,33 0,79 min 40
53 50 175 0,79
1,97 274
M8 2,01 6,89 93 45 10,79 A1
274
B1
5/16 *) 3,66 58 1,77 6 A1
*)
13,5 2,28 0,24 45 10,79
0,53 *) 12 1,77 6
22,5 13,5 0,47 540,24
28 43 56
0,89 98,5 110 0,53 50 6 132 12 1,10 1,69 2,20
346 22,5
3,88 4,33 1,97 0,24 12
5,20 140,47
2,13
13,5
54
13,62 11 0,89 98,5 110 50 0,53
0,43 0,47
294 0,55 70
132 2,13
126,5
4,9811
3,88
287 4,33 1,97 11,57 5,20 266 14
2,76
13,5
240 11,30 10,47 0,55 70
257,5
10,14
210
0,53
9,45 0,43 A126,5 294
80 8,27
4,98 min 40 366...47512 X 395) 3,15
14,41...18,70(OXP 11,57 2,76
A *) N3- types 0,79 366...475 80

OS1200L_
*) N3- types 14,41...18,70(OXP 12 X 395) 3,15
274

05
A1 B1
45 10,79

OS1200L_
*) 1,77 6
13,5 0,24 426
0,53 12 16,77
22,5 0,47 54
0,89 98,5 110 50 132 2,13
11 3,88 4,33 1,97 5,20 14 13,5
0,43 126,5 294 0,55 70 0,53
4,98 11,57 2,76 37,5
A 366...475 80 1,48
14,41...18,70(OXP 12 X 395) 3,15 11
*) N3- types 0,43
20 37,5
OS1200L_

28 43 56 0,79 1,48
1,10 1,69 2,20 6
0,24
47 426 20
266 257,5 210 16,77 0,79
10,47 10,14 8,27 6
0,2

37,5
274 1,48
10,79 A1 B1 C1 11
0,43
OS1200/1250 20
[mm/in] L01 L02 L03 L04 0,79
54
6
A 209/8,23 319/12,56 429/16,89 539/21,22 0,24
2,13 A1 166/6,54 13,5276/10,87 386/15,20 496/19,53
70 B1 0,53
196/7,72 OS1200/1250
306/12,05 416/16,38 526/20,71

2,76 C1 222/8,74
[mm/in] 332/13,07 L01442/17,40 552/21,73
L02 L03 L04
OS1200/1250
80 A
M00207/OS1200-1250_01-04 C 209/8,23 319/12,56 429/16,89 539/21,22
95) 3,15 [mm/in] A1 L01
166/6,54 L02
276/10,87 L03
386/15,20 L04
496/19,53
OS1200L_

A B1 196/7,72 319/12,56
209/8,23 306/12,05 429/16,89
416/16,38 539/21,22
526/20,71
C1 222/8,74 332/13,07 442/17,40 552/21,73
OS1200/1250 A1 166/6,54 276/10,87 386/15,20 496/19,53
[mm/in] L01 M00207/OS1200-1250_01-04
L02 L03 C L04
B1 196/7,72 306/12,05
426 416/16,38 526/20,71
A 209/8,23 319/12,56 429/16,89 539/21,22
A1 166/6,54 C1
276/10,87 222/8,74
386/15,20
16,77
332/13,07
496/19,53 442/17,40 552/21,73
B1 196/7,72 306/12,05 416/16,38 526/20,71
M00207/OS1200-1250_01-04 C
C1 222/8,74 332/13,07 442/17,40 552/21,73

M00207/OS1200-1250_01-04 C
37,5
1,48
11
0,43
20
0,79
6
0,24
125 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Side operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS Mini

OS 16...35FDS30_ OS 16...35FDS40_
OS 20...32FBS30_ OS 20...32FBS40_
OS 25...32FFS30_ OS 25...32FFS40_
EN 50022 * OS 30FA_S30_ * OS 30FA_S40_
OA 3G01 OA 3G01
45 OA 1G10 OSZ 4 OA4B1C OA 1G10 OSZ 4 OA4B1C
max 3+3 max 1+1 6 max 3+3 max 1+1 6
38 74
14...23 75...80
* 75...80
* *
I I
ON ON

O O
35 OFF Ø66 OFF Ø66
97
85
Test Test

* 65 * 65
*
4,5
31 9 4,5 35,6
9
108 14,3 30,8 27,6 14,3 30,8 27,6
110 33 106 33 142
120 129 164
154...166 45 189...201 45

M00222/OS16-35F_S A

55 55

IEC 60269-2-1 BS88-2 BS88-6 OS20FBS40A1F OS20FBS40A1N1 IEC 60269-2-1 BS88-2 BS88-6
IEC 60269-3-1 IEC 60269-2-1 IEC 60269-2-1 OS32FBS40A1F OS32FBS40A1N1 IEC 60269-3-1 IEC 60269-2-1 IEC 60269-2-1
UL 198C OS20FBS30A1 OS32FBS30F1 OS25FFS4010F OS32FBS40F1N1 NFC63210,-63211 OS20FBS40A1 OS32FBS40F1
CSA C22.2 No.106 OS32FBS30A1 OS32FFS4014F OS25FFS4010N1 UL 198C OS32FBS40A1
NFC63210,-63211 OS32FBS30A2 OS16FDS4001F OS32FFS4014N1 OS32FBS40A2
OS25FFS3010 OS35FDS4002F OS16FDS4001N1
OS32FFS3014 OS30FAJS40F OS35FDS4002N1
OS30FAS30J OS30FACCS40F OS30FAJS40N1
OS30FAS30CC OS30FACCS40N1
OS16FDS3001
OS35FDS3002
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 126


Side operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS 40 Mini

OS 40FDS30000 OS40FDS40000
EN 50022 OA 1G10
OA 3G01
OA 3G01 max 2+2+2+2 OA 3G01
50 OA 1G10 OSZ 4 OA4B1C OA 1G10 OSZ 4 OA4B1C 6
max 3+3 max 1+1 max 3+3 max 1+1
38 75...80 6 74 75...80
14...19 14...19

N N
I Ø66 Ø66
35
O Test 97
85
N N

65 65
4,5
56 9 4,5 9 35,6
105 14,3 30,8 27,6 14,3 30,8 27,6
33 115 33 151
141
126 162
157...164 45 36 193...200 45 36

61 61
M00221/OS40FDS_ A

05
DIN 000 OS40FDS40000N1 DIN 000
OS40FDS30000
127 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Side operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS32G...63G_S_

mm mm M5 53
M5 E
53 E
in in 3/16 2,08
3/16 2,08
26,5 26,5 41,5
1,04 1,04 1,63
57 57
2,24 2,24
100 100 112 112 100 100 84 8
3,94 3,94 4,41 4,41 3,94 3,94 114 114 3,31 3
4,49 4,49
mm M5 53 E
Shaft depth in 2,08
Shaft depth 3/16
Min 23/0,91
Min 23/0,91
Max 27/1,06
Max 27/1,06 A1 A1
57
2,24
112
D CD C 36,5 65 100
36,5 65 4,41
3,94
1,44 2,56
1,44 2,56
A (OS30-63G_S_)
A (OS30-63G_S_) Shaft depth
Min 23/0,91
F (OS30_63G_S_K)
F (OS30_63G_S_K) B B
Max 27/1,06

8 D C 36,5 65
8 1,44 2,56
0,31 0,31 A (OS30-63G_S_)
F (OS30_63G_S_K) B
41 41
1,61 1,61 8
26,5 26,5 41,5 41,5 7 0,31
1,04 1,04 1,63 1,63 0,28 7
0,28 41
1,61
7
100 84 0,28
3,94 100114 3,31 84
4,49
3,94 114 3,31
4,49

A1 B1
A1 B1

65
2,56 OS32-63G_
OS32-63G_ OS32-63G_ OS60G_ OS60G_
[mm] DS01 DS02 DS03 DS04 B/FS01 B/FS02 B/FS03
B [mm] DS01
[mm] DS01DS02 DS02DS03 DS03DS04 B/FS01
DS04 B/FS02
B/FS01 B/FS0399,5
B/FS02
A
B/FS04
B/FS03
123
[mm/in]
B/FS04
146,5
JS01
[mm/in]
170 JS01JS02
99,5 123
JS03 146,5
JS02
OS32-63G A 99,5
A 99,5 123 146,5
123 146,5 170 17099,5 99,5 123 146,5
B 123 132,5 170
132,5
146,5 A132,5
170109,5/4,31
132,5
A 144,5/5,69
120,5
109,5/4,31 179,5/7,07 120,5
120,5
144,5/5,69 1792
B 132,5 132,5 132,5 132,5 120,5 120,5 C 120,5 - 23,5
120,5 23,5 130/5,12
B120,5 23,5 -
130/5,12 23,5
130/5,12 23,5
[mm] DS01 BDS02 132,5
DS03 132,5
DS04 132,5
B/FS01 B/FS02 132,5
B/FS03 120,5
B/FS04 D
120,5 56,5
120,5
56,5 56,5
B56,5
130/5,12 56,5
130/5,12 56,5
13 56,5
C C - -23,5 23,523,5 23,523,5 23,5 - -23,5 E 23,5
23,5 30 23,523,5
30
C 23,5
30 C 30- 35/1,38
-
30
35/1,38
35/1,38
30 303
A D 99,5 56,5123 146,5
56,5 170 99,5 56,5 123 146,5 170
D 56,5 56,556,5 56,5 56,556,5 56,556,5 F 56,556,5
116,5 56,5
56,5140 D163,5
56,5 62/2,44
D187 62/2,44
116,5
62/2,44 14062/2,44
62/2,44 163,56
B E132,5 E 132,5
30 132,5
30 30 132,5
30 30 120,5 30 30 120,5 120,5
30 30 120,5
30 30
A1
30 30
61,5 85
30 30 E108,530 36/1,41
E
132 61,5
36/1,41
36/1,41
8536/1,41 108,5
36/1,41 3
B191,5 115 138,5 162,5 91,5 115 138,5 162,5
C F - 116,5
F 23,5 140
116,523,5 163,5
23,5
140 163,5 18723,5 116,5
187 23,5 23,5140
116,5 140163,5 163,5187 F 187 126,5/4,98
F 161,5/6,36
126,5/4,98 196,5/7,74
161,5/6,36 1962
M00296/OS30_63G_01_04S A
A1 61,5
A1 85
61,556,5 85108,5 108,5 132 13261,5 61,5 85 108,5
85 108,5132 A1 13267,5/2,66
A1 102,5/4,04 102,5/4,04
67,5/2,66 137,5/5,41 1371
D 56,5 56,5 56,5 56,5 56,5 56,5 56,5
B191,5 115
B1 91,5 115138,5 162,5
138,5 162,591,5 91,5 115 138,5
115 162,5
138,5 162,5 B137,5/1,4872,5/2,85 107,5/4,23
B137,5/1,48 142,5/5,61 142
72,5/2,85107,5/4,23
E 30 30 30 30 30 30 30 30
M00296/OS30_63G_01_04S A
M00296/OS30_63G_01_04S A
F 116,5 140 163,5 187 116,5 140 163,5 187
A1 61,5 85 108,5 132 61,5 85 108,5 132
B1 91,5 115 138,5 162,5 91,5 115 138,5 162,5
M0029/OS30_63G_01_04S
OS60G_ A
B/FS03 B/FS04 [mm/in] JS01 JS02 JS03 JS04
146,5 170 A 109,5/4,31 144,5/5,69 179,5/7,07 214,5/8,44
120,5 120,5
OS60G_ B 130/5,12OS60G_
130/5,12 130/5,12 130/5,12
B/FS0223,5 B/FS03
23,5 C B/FS04 -[mm/in]35/1,38
JS01 JS02
35/1,38JS03
35/1,38 JS04
12356,5 [mm/
146,5 JS01
17062/2,44A JS02 144,5/5,69JS03 179,5/7,07 JS04
109,5/4,31 214,5/8,44
56,5 D 62/2,44 62/2,44 62/2,44
in]
120,5 30 120,530 E 120,536/1,41B 130/5,12
36/1,41 130/5,12
36/1,41 130/5,12
36/1,41 130/5,12
163,5
23,5 A23,5187 F 109,5/4,31
126,5/4,98C
23,5 144,5/5,69
161,5/6,36 - 179,5/7,07
196,5/7,74
35/1,38 214,5/8,44 35/1,38
231,5/9,11
35/1,38
108,5
56,5 B56,5132 A1 56,5
67,5/2,66
130/5,12 D 102,5/4,04
130/5,12 137,5/5,41
62/2,44 172,5/6,79
130/5,12
62/2,44 130/5,12 62/2,44
62/2,44
162,5
30 B137,5/1,48
30 72,5/2,85 107,5/4,23 142,5/5,61
C 30 E -36/1,41 35/1,38 36/1,41
35/1,38 36/1,41
35/1,38 36/1,41
140 163,5 187 F 126,5/4,98 161,5/6,36 196,5/7,74 231,5/9,11
D 62/2,44 62/2,44 62/2,44 62/2,44
85 108,5 132 A1 67,5/2,66 102,5/4,04 137,5/5,41 172,5/6,79
138,5 E
162,5 36/1,41 36/1,41
B137,5/1,48 36/1,41 142,5/5,61
72,5/2,85107,5/4,23 36/1,41
F 126,5/4,98 161,5/6,36 196,5/7,74 231,5/9,11
A1 67,5/2,66 102,5/4,04 137,5/5,41 172,5/6,79
B1 37,5/1,48 72,5/2,85 107,5/4,23 142,5/5,61
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 128


Side operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS100G...160G_S_

33,4
33,4

93
95,5 93
95,5
88,5 20
88,5 20
8,5 50 50 2,5
8,5 2,5
43 53 43 53
5,5 5,5

26,5 34 26,5 41,5 3


57 57
140 140 C
114,5 114,5 C
114 110114 84
110
Shaft depth
Min 23 Shaft depth
Max 27 Min 23
Max
M527 A1 B1
M5 A1
62,5 35
93 93 62,5 35
B
A (OS100-160G_S_) B
A (OS100-160G_S_)
D (OS100-160G_S_K)
50 50 D (OS100-160G_S_K)
2,5 2,5

,5

05
26,5 26,5 34 26,5 34 41,5 34 41,5 41,5

140 C C C
OS100-160G_
[mm]
114 D/F01 D/F02 D/F03
110 D/F04 B01 84 B02 B03 84 B04
114 114216,5 110111,5 84
A 111,5 OS100-160G_
146,5 181,5 146,5 110 181,5 216,5
B 142 [mm]
142 D/F01 142 D/F02142 D/F03
126,5 D/F04
126,5 B01
126,5 B02
126,5 B03 B04
C 100 A 100 111,5 100 146,5100 181,5
118 216,5
118 111,5
118 146,5
118 181,5 216,5
A1B163,5 A1 B1 B1 C1 126,5 C1
D 128,5 142
198,5 142
233,5 A1
142
128,5 142
163,5 126,5
198,5 B1233,5 126,5 C1
126,5
A1 71,5 106,5
C 141,5
100 176,5
100 71,5
100 106,5
100 141,5
118 176,5118 118 118
B B1 86,5 121,5 156,5
D 191,5
128,5 86,5
163,5 121,5
198,5 156,5
233,5 191,5
128,5 163,5 198,5 233,5
B
C1 101,5 136,5 171,5 206,5 101,5 136,5 171,5 206,5
A1 71,5 106,5 141,5 176,5 71,5 106,5 141,5 176,5
B1 86,5
M00298/OS100_160G_S01_04 A 121,5 156,5 191,5 86,5 121,5 156,5 191,5
OS100-160G_ C1 101,5 136,5 171,5 206,5 101,5 136,5 171,5 206,5

[mm] D/F01 M00298/OS100_160G_S01_04


D/F02 D/F03 D/F04
A B01 B02 B03 B04
A 111,5 146,5 181,5 216,5 111,5 146,5 181,5 216,5
142 142 142 142 142 126,5 126,5 126,5 126,5
C 100 100 100 100 118 118 118 118
D 128,5 163,5 198,5 233,5 128,5 163,5 198,5 233,5
A1 71,5 106,5 141,5 176,5 71,5 106,5 141,5 176,5
B04 B1 B04 86,5 121,5 156,5 191,5 86,5 121,5 156,5 191,5
B02 B03
B01 216,5 B02 B03 B04
46,5 181,5 C1216,5 101,5 136,5 171,5 206,5 101,5 136,5 171,5 206,5
111,5 126,5126,5
26,5 146,5 181,5
126,5 216,5
M00298/OS100_160G_S01_04 A
126,5 118 126,5 126,5 126,5
118 118 118
233,5
63,5118 198,5118 233,5 118 118
128,5 176,5141,5
06,5 163,5 198,5
176,5 233,5
71,5
56,5 106,5
191,5 141,5 176,5
121,5
71,5 156,5
206,5 191,5
136,5 171,5 206,5
129 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Side operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS100GJS

mm mm 33,4 33,4 93 93
in in 1,31 1,31 3,66 3,66

20 50 2,5 2,5
88,5 20 1,97 0,10 50 0,10
95,5
95,5 3,48
88,5 0,79
0,79 1,97
3,76 3,48
3,76
53 11
43 2,08 53 0,43 11
1,69 43 2,08 0,43
1,69 26,5
1,04 26,5
57 220 1,04
2,24 57 150 8,66 220
100 125,5
3,94 2,24 5,91 150 8,66 4,94
100 125,5 114
3,94 5,91 172 4,94
6,77 138,5 4,49 114
Shaft depth 172 5,45 4,49
Min 23/0,91 6,77 138,5
Shaft depth
Max 27/1,06 5,45
Min 23/0,91
Max 27/1,06
M5 A1
3/16 Ø8,5
M5 0,33
62,5 35
3/16 Ø8,5
2,46 1,38 116,5
93 93 0,33 4,59
3,66 3,66 62,5
A (OS100GJS_) 35
2,46 1,38 116,5
B (OS100GJS_K )
A (OS100GJS_) 4,59
50 2,5 50 2,5
1,97 0,10 1,97 0,10 B (OS100GJS_K )

43 OS100G_
26,5 JS01
[mm/in] JS02 26,5
34 JS03 3441,5
26,5
JS04 3441,5 41,5
1,04 1,04
1,34 1,34
1,04 1,63 1,63
1,34 1,63
A OS100G_
111,5/4,39 146,5/5,77 181,5/7,15 216,5/8,52
220 [mm/in] JS01 JS02 JS03 JS04
5 8,66 B
125,5 128,5/5,06 163,5/6,44 198,5/7,91 233,5/9,19
4,94 125,5
A1 A
114 71,5/2,81 4,94 114
111,5/4,39 146,5/5,77
106,5/4,19 141,5/5,57181,5/7,15 84
110216,5/8,52
176,5/6,95 84 84
110 114 3,31 110
3,31
38,5 172 4,49
138,5
B1 86,5/3,41
B 121,5/4,78 4,49
138,5
156,5/6,16
128,5/5,06 4,33191,5/7,54198,5/7,91
163,5/6,44 4,33
4,49 233,5/9,19 3,31
,45 6,77 5,45 4,33
5,45
C1101,5/4,00
A1 136,5/5,37
71,5/2,81171,5/6,75 206,5/8,13141,5/5,57
106,5/4,19 176,5/6,95
B186,5/3,41121,5/4,78
M00296/OS30_63G_01_04S A 156,5/6,16 191,5/7,54
A1 136,5/5,37171,5/6,75 A1B1 B1 B1C1
C1101,5/4,00 206,5/8,13 A1 C1 C1
M00296/OS30_63G_01_04S A
116,5
4,59 116,5
4,59
OS100G_
[mm/in] JS01 JS02 JS03 JS04
A 111,5/4,39 146,5/5,77 181,5/7,15 216,5/8,52
B 128,5/5,06 163,5/6,44 198,5/7,91 233,5/9,19
A1 71,5/2,81 106,5/4,19 141,5/5,57 176,5/6,95
B1 86,5/3,41 121,5/4,78 156,5/6,16 191,5/7,54
C1 101,5/4,00 136,5/5,37 171,5/6,75 206,5/8,13
M00296/OS30_63G_01_04S A
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 130

75
OS 200: 43 / 1,69
— OS 250: 53 / 2,09
2,95

Side operated switchOSfuses,


4,33/1,81 IEC
200:110/46
and UL/CSA
53,5 3
D M OS 250:116/46 2,11 0,12
Dimensional drawings
4,57/1,81

OS200...250_S_ (IEC only)


5,5 8,5 17,5
0,22 0,33 0,6
OS200_, OS200_K F
[mm/ BDS01 BS01 75 CDS02 BS02 DS03 BS03 DS04 BS04
OS 200: 43 / 1,69
in] 2,95 139
144 5,47
OS 250: 53 / 2,09 5,67
A 162,0/6,38 143,0/5,63
OS 200:110/46 162,0/6,38 143,0/5,12 162,0/6,38 143,0/5,63 162,0/6,38 143,0/5,63
4,33/1,81 53,5 3
B 164,5/6,48
OS 250:116/46 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48
2,11 0,12
C 4,57/1,81
198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81
D 8,5/0,33 8,5/0,33 E8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 A1

E 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44


39,5 36,5/1,44
65 36,5/1,44 36,5/1,44 36,5/1,44
H I
F 144,5/5,695,5 144,5/5,69 144,5/5,69 1,56
144,5/5,69 2,56
144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 17,5
S200/250_) 8,5
G 48,5/1,910,22 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91
A 48,5/1,91 48,5/1,91
0,33 48,5/1,91 0,69 26,5
/250_K) 75 F 1,04
H 2,95 C -/- -/- 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71
B 139
I 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 144 20,0/0,79 20,0/0,79 5,47 108
200:110/46 5,67 4,25
,33/1,81 53,5
J 3138,5/5,45 138,5/5,45 182,0/7,17 182,0/7,17 225,5/8,88 225,5/8,88 269,0/10,59 269,0/10,59
:116/46 2,11 0,12
81 K 40,0/1,57 40,0/1,57 40,0/1,57 40,0/1,57 40,0/0,39 840,0/1,57 40,0/1,57 40,0/1,57
L E 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 B1
A1
M 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33
39,5 65 OS250_, OS250_K

05
N 121,5/4,78 121,5/4,78 165,0/6,50 165,0/6,50 208,5/8,21 208/8,21 252,0/9,92 252,0/9,92
5,5 1,56 2,56 8,5 17,5
1 0,22 DS02
A1 BS02
60,5/2,38 60,5/2,38 DS03
104,0/4,09 BS03
104,0/4,09 DS04
147,5/5,81
0,33 BS04 191,0/7,52
147,5/5,81 0,69 [mm/in] DS01
191,0/7,52 26,5BS01 DS02
F A 1,04
3 162,0/6,38
B1 143,0/5,12
79,5/3,13 162,0/6,38
79,5/3,13 143,0/5,63
123,0/4,84 123,0/4,84 162,0/6,38
166,5/6,56 143,0/5,63 210,0/8,27
166,5/6,56 A 154,0/6,06
210,0/8,27 154,0/6,06 154,0/6,06 154,0/
C
139
8 164,5/6,48
C1 164,5/6,48
96,5/3,80 164,5/6,48
96,5/3,80 164,5/6,48
140,0/5,51 144 164,5/6,48
140,0/5,51 183,5/7,22 164,5/6,485,47
183,5/7,22 B
227,0/8,94 162,0/6,38
227,0/8,94 162,0/6,38
108 162,0/6,38 162,0/
5,67 4,25
1 198,5/7,81 198,5/7,81
M00153/OS200-250_SO01-04_ C 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 C 193,0/7,60 193,0/7,60 193,0/7,60 193,0/
3 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 D 4,0/0,16 4,0/0,16 4,0/0,16 4,0/
4 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 A1
36,5/1,44 E 33,5/1,32
B1 33,5/1,32 33,5/1,32 33,5/
C1
9 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 F 148,5/5,85 148,5/5,85 148,5/5,85 148,5/
39,5 65 OS250_, OS250_K
1 48,5/1,91
1,56 2,56 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 G 53,5/2,11 53,5/2,11 53,5/2,11 53,5/
BS02 DS03 BS03 DS04 BS04 [mm/in] DS01 BS01 DS02 BS02
/- 43,5/1,71 A 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 H -/- 54,0/2,13 75 54,0/2,13 54,0/
143,0/5,12 162,0/6,38 143,0/5,63 162,0/6,38 143,0/5,63 A 154,0/6,06 154,0/6,06 154,0/6,06
OS 200: 43 / 1,69 154,0/6,06 2,95
OS250_, OS250_K OS 250: 53 / 2,09
9164,5/6,48
20,0/0,79 20,0/0,79
164,5/6,48 164,5/6,4820,0/0,79
164,5/6,48 20,0/0,79
164,5/6,48 20,0/0,79
B 20,0/0,79 162,0/6,38
162,0/6,38 I 25,0/0,98
162,0/6,38 25,0/0,98
162,0/6,38
OS 200:110/46 25,0/0,98 25,0/
4,33/1,81 53,5 3
[mm/ DS01 BS01 DS02 BS02 70 K OS 250:116/46
5198,5/7,81
182,0/7,17 182,0/7,17
198,5/7,81 225,5/8,88
198,5/7,81 225,5/8,88
198,5/7,81 269,0/10,59
198,5/7,81 C 269,0/10,59
193,0/7,602,76 J
D
193,0/7,60
M
148,5/5,85
193,0/7,60 202,5/7,97
193,0/7,60
4,57/1,81
2,11
256,5/10,10
0,12
310,5/1
in] L
E
7 8,5/0,33
40,0/1,57
A
40,0/1,57 154,0/6,06
8,5/0,33
154,5/6,06 8,5/0,33
40,0/0,39 840,0/1,57
8,5/0,33
154,0/6,06 8,5/0,33 40,0/1,57
154,0/6,06 D 40,0/1,57
4,0/0,16 K
4,0/0,16 45,0/1,77
4,0/0,16 45,0/1,77
4,0/0,16 45,0/1,77 45,0/
9 36,5/1,44
10,0/0,39
B 36,5/1,44
10,0/0,3936,5/1,44
162,0/6,38
10,0/0,39
162,0/6,38 36,5/1,44
10,0/0,39
162,0/6,38 36,5/1,44
10,0/0,39
162,0/6,38 E 10,0/0,39
33,5/1,32
72
2,83
L
33,5/1,32 11,0/0,43
33,5/1,32 11,0/0,43
33,5/1,32
5,5 11,0/0,43 11,0/
0,22
126 F
3144,5/5,69
8,5/0,33
C 144,5/5,698,5/0,33
144,5/5,69
193,0/7,60 8,4/0,33
193,0/7,60 144,5/5,69 8,5/0,33
193,0/7,60 193,0/7,60 8,5/0,33
144,5/5,69 F 8,5/0,33 148,5/5,85
148,5/5,85
4,96 M 11,5/0,45
148,5/5,85
B
11,5/0,45
148,5/5,85
C 11,5/0,45 11,5/
8 48,5/1,91 D 48,5/1,91
165,0/6,50 165,0/6,5048,5/1,91
4,0/0,16 4,0/0,16 48,5/1,91
208,5/8,21 48,5/1,91
208,5/8,21
OS250_, OS250_K
4,0/0,16 G
252,0/9,92
4,0/0,16 53,5/2,11
252,0/9,92 53,5/2,11
N 53,5/2,11
131,5/5,18 53,5/2,11
186,0/7,32 240,0/9,45 294,0/1
8 43,5/1,71
BS03 E 43,5/1,71
104,0/4,09 104,0/4,09
DS04 43,5/1,71
33,5/1,30 BS04
33,5/1,32 43,5/1,71
147,5/5,81 [mm/in]
33,5/1,32 43,5/1,71
147,5/5,81
DS01 33,5/1,32 BS01H
191,0/7,52 -/-
191,0/7,52
DS02 54,0/2,13 A1
BS02 54,0/2,13
70,5/2,78 54,0/2,13
124,5/4,90 178,5/7,03 232,5/
20,0/0,79
84 143,0/5,63
123,0/4,84
F
20,0/0,79
162,0/6,38
166,5/6,56
148,5/5,85
20,0/0,79
143,0/5,63
148,5/5,85
20,0/0,79
166,5/6,56 A 20,0/0,79
154,0/6,06
210,0/8,27
148,5/5,85 154,0/6,06I 25,0/0,98
210,0/8,27 154,0/6,06
148,5/5,85
25,0/0,98
154,0/6,06 25,0/0,98 25,0/0,98
B189,5/3,52143,5/5,65197,5/7,78 251,5/9,90
G H I 39,5 65

51182,0/7,17
164,5/6,48 225,5/8,88
G 164,5/6,48
225,5/8,88
53,5/2,11164,5/6,48
269,0/10,59
B 53,5/2,11 269,0/10,59
162,0/6,38 162,0/6,38J 148,5/5,85
162,0/6,38 202,5/7,97
162,0/6,38 256,5/10,10 310,5/12,22 1,56 2,56
140,0/5,51 183,5/7,22 183,5/7,22
53,5/2,11 227,0/8,94 227,0/8,94
53,5/2,11 C1106,5/4,19
N (OS200/250_) 214,5/8,44 268,5/10,57 322,5/12,70
A
40,0/1,57
198,5/7,81 40,0/0,39
198,5/7,81 840,0/1,57
198,5/7,81 40,0/1,57
C 40,0/1,57
193,0/7,60 193,0/7,60K 45,0/1,77
193,0/7,60 45,0/1,77
J (OS200/250_K)
193,0/7,60 45,0/1,77 45,0/1,77
H -/- 54,0/2,13 54,0/2,13 54,0/2,13
10,0/0,39
8,5/0,33 I 10,0/0,39
8,5/0,33 10,0/0,39 10,0/0,39 10,0/0,39 4,0/0,16L 11,0/0,43 11,0/0,43 11,0/0,43 11,0/0,43
25,0/0,98 8,5/0,33
25,0/0,98 D25,0/0,98
4,0/0,1625,0/0,98 4,0/0,16 4,0/0,16
75
8,5/0,33
36,5/1,44 8,4/0,33
36,5/1,44 8,5/0,33
36,5/1,44 8,5/0,33
E 33,5/1,328,5/0,3333,5/1,32 M
OS 200: 43 / 1,69
OS 250: 53 / 2,09 11,5/0,45
33,5/1,32 11,5/0,45
2,95
33,5/1,32 11,5/0,45 11,5/0,45
J 148,5/5,85 202,5/7,97 256,5/10,10 310,5/12,22
OS 200:110/46
165,0/6,50
144,5/5,69 208,5/8,21
144,5/5,69 208,5/8,21
144,5/5,69 252,0/9,92 252,0/9,92
F K 148,5/5,85 148,5/5,85N 131,5/5,18
148,5/5,85
4,33/1,81 186,0/7,32
148,5/5,85
53,5 3 240,0/9,45 294,0/11,57
K 45,0/1,77 45,0/1,77 70 45,0/1,77 D M 45,0/1,77 OS 250:116/46
OS200_, OS200_K 2,11 0,12 OS2
104,0/4,09
48,5/1,91 147,5/5,81
48,5/1,91 147,5/5,81
48,5/1,91 191,0/7,52
2,76
G 191,0/7,52
53,5/2,11 53,5/2,11 A1 70,5/2,78
53,5/2,11
4,57/1,81
[mm/in] DS01 124,5/4,90
53,5/2,11
BS01 DS02 178,5/7,03
BS02 232,5/9,15BS03
DS03 DS04 BS04 [mm
L 11,0/0,43 11,0/0,43 11,0/0,43
L 11,0/0,43
A 162,0/6,38 143,0/5,63 E 162,0/6,38 143,0/5,12 162,0/6,38 143,0/5,63 162,0/6,38 143,0/5,63 A
166,5/6,56
43,5/1,71 166,5/6,56
43,5/1,71 210,0/8,27
43,5/1,71 210,0/8,27
H -/- 54,0/2,13B189,5/3,52 143,5/5,65
54,0/2,13 197,5/7,78
54,0/2,13 251,5/9,90
M 11,5/0,45 11,5/0,45 11,5/0,45 11,5/0,45 B 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 B
183,5/7,22
20,0/0,79 183,5/7,22
20,0/0,79 227,0/8,94
20,0/0,7972 227,0/8,94
I 25,0/0,98 25,0/0,98C1106,5/4,19 214,5/8,44
25,0/0,98
C 198,5/7,81
5,5
268,5/10,57
25,0/0,98
198,5/7,81 322,5/12,70
198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 C
N 131,5/5,18 186,0/7,32
2,83 240,0/9,45 294,0/11,57 D 8,5/0,33
0,22 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5 8,5/0,33 8,5/0,33
17,5
0,69D
225,5/8,88 269,0/10,59 269,0/10,59
126 J 148,5/5,85 202,5/7,97 256,5/10,10
E 36,5/1,44 310,5/12,22
36,5/1,44 36,5/1,44 F
36,5/1,44 36,5/1,44 36,5/1,44
0,33
36,5/1,44 36,5/1,44 E
A1 70,5/2,78 124,5/4,90
4,96 178,5/7,03 232,5/9,15 B F C
144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 139 F
840,0/1,57 40,0/1,57 40,0/1,57 K 45,0/1,77 45,0/1,77 45,0/1,77 45,0/1,77 144
B1 89,5/3,52 143,5/5,65 197,5/7,78 251,5/9,90 G 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91
5,67 48,5/1,91 48,5/1,915,47 G
10,0/0,39 10,0/0,39 10,0/0,39 L 11,0/0,43 11,0/0,43 11,0/0,43
H -/- 11,0/0,43
-/- 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 H
C1 106,5/4,19 214,5/8,44 268,5/10,57 322,5/12,70 I 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 I
8,5/0,33 8,5/0,33 8,5/0,33 M 11,5/0,45 11,5/0,45 11,5/0,45
J 138,5/5,45 11,5/0,45182,0/7,17
138,5/5,45 182,0/7,17 225,5/8,88 225,5/8,88 269,0/10,59 269,0/10,59 J
M00528/ OS60GJ11-22 A A1
208,5/8,21 252,0/9,92 252,0/9,92 N 131,5/5,18 186,0/7,32 240,0/9,45
K 40,0/1,57
294,0/11,57
40,0/1,57 40,0/1,57 40,0/1,57 40,0/0,39 840,0/1,57 40,0/1,57 40,0/1,57 K
G H I L 10,0/0,39 10,0/0,39 65 10,0/0,39
39,5 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 L
147,5/5,81 191,0/7,52 191,0/7,52 A1 70,5/2,78 124,5/4,90 178,5/7,03
M 8,5/0,33 232,5/9,15
1,568,5/0,332,56 8,5/0,33 8,5/0,33 8,4/0,33 8,5/0,33 8,5/0,33 8,5/0,33 M
N (OS200/250_)
N 121,5/4,78 121,5/4,78 A 165,0/6,50 165,0/6,50 208,5/8,21 208,5/8,21 252,0/9,92 252,0/9,92 N
210,0/8,27 210,0/8,27 B189,5/3,52143,5/5,65197,5/7,78
J (OS200/250_K) 251,5/9,90
A1 60,5/2,38 60,5/2,38 104,0/4,09 104,0/4,09 147,5/5,81 147,5/5,81 191,0/7,52 191,0/7,52 A1
227,0/8,94 227,0/8,94 C1106,5/4,19214,5/8,44268,5/10,57 322,5/12,70
B179,5/3,1379,5/3,13123,0/4,84 123,0/4,84 166,5/6,56 166,5/6,56 210,0/8,27 210,0/8,27 B18
C196,5/3,8096,5/3,80140,0/5,51 140,0/5,51 183,5/7,22 183,5/7,22 227,0/8,94 227,0/8,94 C11

M00153/OS200-250_S01-04_ C
131 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Side operated switch fuses, IEC and UL/CSA
Dimensional
81 81 drawings
81 3.19
56,53.19 556,5 3.19
/130.9
52.22 0.20 5
0/5.15
.20 2.22 0.20
OS315...400_S_

86 58,5
40 40 86 3.39
58,5 2.30
81
1.56 1.56 3.39 2.30 10,8 81 3.19
10,8 0.43 55,8/130.9 56,5
3.19 5
0.43 56,5
55,8/130.9 2,20/5.155 2.22 0.20
7,5 2,20/5.15 2.22
7,5 0.20
0.30
5 11,50.30
0.20 11,5
0.45
0.45 40
40
1.56
1.56
82
230 82
3.23 D 3.23
D D 5 5
0.20
0.20
9.06 201 201
149 149 7.91 7.91
5.87 230 230 D D
5.87 9.06 9.06

75,5 64 25 46,5 95
75,5 64 25 46,5 95
6,5
95 95
46,5 95 2.97 2.52
2.97 2.520.98 1.83 3.74
3.74
B (OS315/400_) 0.98 C 1.83
83
3.74 3.74
1.83 3.74 B (OS315/400_)
A (OS315/400_K) C
A (OS315/400_K)
C C C
17
0.67 26
1.02 26,5
17 1.04
0.67 26
1.02 26,5
1.04
164 159 108
6.46 6.26 4.25
164 159 108
17 17 6.46 6.26 4.25
17 0.67 26 26
0.67 0.67 26 1.02 1.02 26,5 26,5
1.02 26,5 1.04 A1 B1 C1
1.04 1.04
A1 B1

164 164 164 159 159 159 108 108


6.46 6.46 OS400_K 6.26 6.26 108 4.25 4.25
6.46 OS315, OS315_K, OS400, 6.26 OS400_, 4.25
OS400_K
Piirustus No.
BS01/JS01 BS02/JS02 BS03/JS03 BS04/JS04 DS01 DS02 DS03 DS04 13/OS315-400_S01-04_ C
M00154/OS315-400_S01-04_ C

Document No.
mm in mm in
OS315, mm
OS315_K, in OS400,
mm OS400_K
in mm in mm in mm in
OS400_, mmOS400_K in
Teki 2012-08-30 Tarkasti
Piirustus No. Hyväksyi
A 185,0 7.28 249,0 9.80 BS02/JS02
BS01/JS01 313,0 12.32 BS03/JS03
377,0 14.84 185,0 7.28 249,0 DS01
BS04/JS04 9.80 313,0 DS0212.32 377,0 DS03 14.84 DS04 Prepared T Mäkkylä Checked
13/OS315-400_S0
Approved
M00154/OS315-400_S01-04_ C

Document No.
B 160,0 6.30mm 224,0 in8.82 mm 288,0 in11.34 mm352,0 13.86
in 160,0
mm 6.30
in 224,0
mm 8.82in 288,0
mm B111.34 in 352,0
mm 13.86in mm in
C 189,0 A 7.44185,0
189,0 189,0A1
7.44 249,0 A17.44 206,0 B1 C1 C1 2012-08-30
9.807.44 313,0
189,0 12.32 8.12 206,0
185,08.12
7.28206,0
249,0 8.129.80206,0 C18.12
A1 7.28 B1 14.84 Teki Tarkasti
377,0 313,0 12.32 377,0 14.84 ABB Oy BreakersTand
Prepared Switches
Mäkkylä Checked
D 194,0 7.64 194,0 7.64 194,0
B 160,0 6.30 224,0 8.827.64 288,0
194,0 7.64 166,0 6.54 166,0 6.54 166,0
11.34 352,0 13.86 160,0 6.30 224,0 6.54 8.82166,0
288,0 6.54
11.34 352,0 13.86
A1 98,5 3.88 162,5 6.40 226,5 8.92 290,5 11.44 98,5 3.88 162,5 6.40 226,5 8.92 290,5 11.44
C 189,0 7.44 189,0 7.44 189,0 7.44 189,0 7.44 206,0 8.12 206,0 8.12 206,0 8.12 206,0 8.12
B1 116,5 4.59 180,5 7.11 244,5 9.63 308,5 12.15 116,5 4.59 180,5 7.11 244,5 9.63 308,5 12.15 ABB Oy Breaker
C1 134,5 D 5.30194,0
198,57.64
7.81 194,0
262,57.64
10.33 194,0 7.64 194,0
326,5 12.85 7.64 198,5
134,5 5.30 166,07.81
6.54262,5
166,010.336.54326,5
166,012.856.54 166,0 6.54
A1 98,5 3.88 162,5 6.40 226,5 8.92 290,5 11.44 98,5 3.88 162,5 6.40 226,5 8.92 290,5 11.44
OS400_, OS400_K
OS400_K B1 116,5 4.59 180,5 7.11 244,5 9.63 308,5 12.15 116,5 4.59 180,5 7.11 244,5 9.63 308,5 12.15
C1 134,5 5.30 198,5 7.81 262,5 10.33No. 326,5 Piirustus
12.85 No.
134,5 Piirustus
5.30 198,5No. 7.81 262,5 10.33 326,5 12.85
DS02
DS03DS04 DS03 DS04 OS400, OS400_K
OS315, OS315_K,
DS04 OS400, OS400 K Piirustus
13/OS315-400_S01-04_ C
Document No. Document No. 13/OS315-400_S01-04_
13/OS315-400_S01-04_
Document No.
C C
mm
mm mm inin mm in in mm
in mm [mm/in] in BS02/JS02 BS03/JS03 BS04/JS04
BS01/JS01 [mm/in] DS01Tarkasti DS02 Hyväksyi DS03 DS04
Teki Teki
2012-08-30 2012-08-30
Teki 2012-08-30
Tarkasti Hyväksyi
49,0
313,0
32 9.80
12.32
377,0 313,0
14.84377,012.32
14.84377,0 14.84 Prepared
Tarkasti
Prepared
T Mäkkylä
Hyväksyi
T Mäkkylä
Checked Checked Approved
A Prepared
185,0/7,28 249,0/9,80 313,0/12,32 T377,0/14,84
Mäkkylä CheckedA 185,0/7,28 Approved
Approved 249,0/9,80 313,0/12,32 377,0/14,84
24,0
288,0
34 8.82
11.34
352,0 288,0
13.86352,011.34
13.86352,0 13.86
06,0
206,0
12 206,0B8.128.12206,0
8.128.12206,0
206,0 8.12 160,0/6,30
8.12 224,0/8,82 288,0/11,34 352,0/13,86 B 160,0/6,30 224,0/8,82 288,0/11,34 352,0/13,86
66,0 6.54 166,0 6.54 166,0 6.54 ABB Oy ABB Oy ABBBreakers
Oy and Switches
Breakers and Breakers
Switchesand Switches
166,0
54 166,06.546.54 166,0C 6.54 189,0/7,44 189,0/7,44 189,0/7,44 189,0/7,44 C 206,0/8,12 206,0/8,12 206,0/8,12 206,0/8,12
62,5
226,5
92 6.408.92
290,5 226,5
11.44290,5D8.92
11.44290,5 11.44
194,0/7,64 194,0/7,64 194,0/7,64 194,0/7,64 D 166,0/6,54 166,0/6,54 166,0/6,54 166,0/6,54
80,5
244,5
63 7.119.63
308,5 244,5
12.15308,5 9.63
12.15308,5 12.15
98,5 7.81 262,5 A1 98,5/3,88 162,5/6,40 226,5/8,92 290,5/11,44 A1 98,5/3,88 162,5/6,40 226,5/8,92 290,5/11,44
262,5
33 10.33
326,5 12.85326,510.33
12.85326,5 12.85
B1 116,5/4,59 180,5/7,11 244,5/9,63 308,5/12,15 B1 116,5/4,59 180,5/7,11 244,5/9,63 308,5/12,15
C1 134,5/5,30 198,5/7,81 262,5/10,33 326,5/12,85 C1 134,5/5,30 198,5/7,81 262,5/10,33 326,5/12,85
M00154/OS315-400_S01-04_ C
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 132


Side operated switch fuses, IEC and UL/CSA
Dimensional drawings

OS600...OS800_S_
6 6 6
6 6 62 62 620.24 0.24 0.24
0.24 23 137/62
13,5 230.24 mm 23 137/62 137/62
2.44
mm 2.44
5,4/2.44 2.44
50 50 50
0.53 0.91 0.91
in
5,4/2.44
0.91
in 5,4/2.44
1.97 6
107,5 107,5
77,5 77,5 6 1.97 6 1.97 6
0.24 0.24
4.24 4.24
3.05 3.05 0.24
13,5 13,5 0.24
23 137/62 62
23 137/62 62
2.44
0.53 0.91 0.91 2.44
5,4/2.44 5,4/2.44 50 50
M8 M8 0.53 1.97
1.97
5/16 5/16
5 5 5
0.20 1160.20
116 0.20 ON ON ON
5 5
0.20 0.20
259,5 259,5 306 306
4.57 259,5
4.57 306 230
259,5306230 306230
ON
ON

259,5 230
10.22 10.22
206
8.12
206 12.06 12.06
10.22 O 12.06
O
OFF
OFF OFF OFF

O 10.22 9.06
10.22 9.06
12.06 9.06O
12.06
OFF

9.06
230
9.06
O
O
8.12
OFF OFF
O
ON
ON

122,5 88 39
4.83 122,5
3.46 88 1.54 39 144
4.83 3.46 1.54 62 5.67 144
88 39 39 39 B (OS600/800_)
B (OS600/800_) 2.44 62 247 5.67
3.46 1.54 1.54 1.54 144 144 144 2.449.73 247
A (OS600/800_K) 5.67 5.67 9.73
62 62 A (OS600/800_K)
62 5.67
800_)
OS600/800_) 2.44 2.44 247
2.44 247 24745 73
60 2.87
9.73 9.73 1.77
9.73 45
1.77
2.36 60
73
2.87
0_K)
600/800_K) 2.36
M00146/OS600-800_S01_-04_ C

M00146/OS600-800_S01_-04_ C

232 223

05
176
9.14 8.79
OFF OFF OFF
O

6.93
O O

ON

232
ON ON

73 223 176
45 45 45 9.14 73 73 8.79
OFF OFF OFF
O

6.93
O O

60 60 60 2.87 2.87
ON ON ON

1.77 1.77 1.77 2.87


2.36 2.36 2.36
OS600/630/800_ , OS600/630/800_K A1 B1 C1
DS/BS/JS/LS01 DS/BS/JS/LS02 DS/BS/JS/LS03 DS/BS/JS/LS04 B1
OS600/630/800_ , OS600/630/800_K A1 C1
mm / in mm / in mm / in
232 mm / in232 223
DS/BS/JS/LS01 232 DS/BS/JS/LS02 223
DS/BS/JS/LS03 176
223DS/BS/JS/LS04 176 176
A 9.14238/9.389.14 mm326/12.84 414/16.31 502/19.78 Piirustus No.

9.14 mm8.79
OFF OFF OFF
O

8.79 mm / 6.93
O O

8.79 13/OS600-800_S01_-04_ C
OFF OFF OFF

mm / in
OFF
O

/ in in 6.93
OFF OFF
O O

/ in
O

6.93
O O
Document No.
ON ON ON

B 213/8.39 301/11.86 389/15.32 477/18.79


ON ON ON
ON ON ON

A 238/9.38 414/16.31
235,5/9.28 326/12.84 502/19.78 Teki 08-02-25 Piirustus No.
Tarkasti Hyväksyi
A1 147,5/5.81 323,5/12.75 411,5/16.21 Prepared T Mäkkylä Document No.
Checked 13/OS600-800_S01_-04_
Approved C
B1 B
177,5/6.99 213/8.39
265,5/10.46301/11.86
353,5/13.93
389/15.32
441,5/17.39 477/18.79 Teki 08-02-25 Tarkasti Hyväksyi

C1 A1
203,5/8.02 147,5/5.81
291,5/11.48
235,5/9.28
379,5/14.95 323,5/12.75
467,5/18.42 411,5/16.21 ABB Oy
Prepared
LowTVoltage
MäkkyläProducts
Checked Approved

B1 177,5/6.99 265,5/10.46 353,5/13.93 441,5/17.39


_K, OS600/630/800_K A1 B1 B1 B1 C1
/630/800_K
0_ C1 203,5/8.02 A1
291,5/11.48 A1 379,5/14.95 467,5/18.42 C1 C1 ABB Oy Low Voltage Products

DS/BS/JS/LS04
BS/JS/LS03 DS/BS/JS/LS04DS/BS/JS/LS04
DS/BS/JS/LS03
2
mm / in mmmm / in/ in mm / in mm / in
502/19.78
4/16.31 502/19.78 502/19.78
414/16.31
Piirustus No.
Document No.
Piirustus No.
Piirustus No.
13/OS600-800_S01_-04_ C
Document No. 13/OS600-800_S01_-04_
Document No. C
13/OS600-800_S01_-04_ C
477/18.79
9/15.32 389/15.32
477/18.79 477/18.79 Teki 08-02-25
411,5/16.21 OS600/630/800_, OS600/630/800_K Prepared
Teki
TPrepared
Mäkkylä
Tarkasti
08-02-25
Teki
Hyväksyi
08-02-25
Tarkasti Hyväksyi
Tarkasti Hyväksyi
83,5/12.75 411,5/16.21
323,5/12.75 411,5/16.21
Checked
T Mäkkylä
Prepared
Approved
T Mäkkylä
Checked Approved
Checked Approved

441,5/17.39
3,5/13.93
46 [mm/in]
441,5/17.39
353,5/13.93 DS/BS/JS01
441,5/17.39 DS/BS/JS02 DS/BS/JS03 DS/BS/JS04
ABB Oy
8 467,5/18.42
9,5/14.95 467,5/18.42
379,5/14.95 A 467,5/18.42238,0/9,38 326,0/12,84 ABBLow
414,0/16,31 ABB502,0/19,78
Oy Oy Voltage Products
Low Voltage Products
Low Voltage Products

B 213,0/8,39 301,0/11,86 389,0/15,32 477,0/18,79


A1 147,5/5,81 235,5/9,28 323,5/12,75 411,5/16,21
B1 177,5/6,99 265,5/10,46 353,5/13,93 441,5/17,39
C1 203,5/8,02 291,5/11,48 379,5/14,95 467,5/18,42
M00146/OS600-800_S01_-04_ C
133 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses
Dimensional drawings

OS200_12/22_ and OS250_12/22 (BB)

75
75
20
G 20 K OS 200:110/46 40,5
I 3 40,5
OS 200:110/46
OS 250:116/46
M5 G I K 3
M5 L OS 250:116/46
J L
33,5 J 5,5 C
33,5 *) 5,5 C 6 A2
*) 45 6 A2
72 3 45
72 3 D
144 M B 59 B D
144 M 59 144
Back connection types: 126 144
Back connection types: 126 65
65
49 A1
) 49
* ) ø11 14 min
10,5 8,6
8,4 10,5
* ø11 14 min
8,6 12,5 A
75 N F 8,4
12,5 189...254 A
E N F G (OXP 6X210) 189...254
E G (OXP 6X210)
H *) OS_N3:
5 3 H *) OS_N3:

C
6 6 A2 B2A2 B2 B2
A2 C2 C2 C2
45 45

D D D
144 144 138,5
144 138,5 138,5
108 108 108

65 65 65

A1 A1 B1A1 B1 C1B1 C1 C1
in 14 min
A
189...254 OS200 OS250
) (OXP 6X210)OS200 [mm] OS200
D11 B11 D12 B12 D13 B13 D22 B22 OS250
[mm]
OS250
D11 D12 D13 D22
[mm] D11 B11 D12 B12 D13 B13 D22 B22 [mm] D11 D12 D13 D22
[mm] A D11 149 B11 130 D12 149 B12 130 D13 141B13 D22
130 B22
149 130 [mm]
A D11
154 D12
154 D13
154 D22
154
A 149 130 149 130 141 130 149 130 A 154 154 154 154
A B 149 199 130 199 199 130 199 141 199130 199 199 199 AB 193 193 193 193
B 199 149 199 199 199 149
199 130
199 199 199 154
B 154
193 154
193 154
193 193
C 36,5 36,5 36,3 36,5 36,5 36,5 36,5 36,5 C 33,5 33,5 33,5 33,5
B 199 C 199 36,5 199 36,5 199 36,3199 36,5199 199
36,5 199
36,5 36,5 B 36,5 C
193 33,5
193 33,5
193 33,5
193 33,5
D 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5 D 148,5 148,5 148,5 148,5
C 36,5 92D 36,5 144,5 36,5 144,536,5 144,536,5 144,5
36,5 144,5
36,5 144,5
36,5 144,5 144,5 D 148,5 148,5 148,5 148,5
E 92 92 92 92 92 135,5 135,5 CE 33,5
112,5 33,5
112,5 33,5
112,5 33,5
161
E 92 92 92 92 92 92 135,5 135,5 E 112,5 112,5 112,5 161
D F 144,5 43,5 144,5 43,5 144,5 43,5144,5 43,5 144,5 144,5
43,5 144,5
43,5 144,5
43,5 43,5 DF 54
148,5 54
148,5 54
148,5 148,554
F 43,5 43,5 43,5 43,5 43,5 43,5 43,5 43,5 F 54 54 54 54
G 92 20 92 20 20 92 20 92 20 92 20 20 20
E G 20 92 20 20 20 135,5
20 135,5
20 20 EG 20
25
112,5
G
25
112,5
25
25
112,525 16125
25 25
H 132 132 175,5 175,5 219 219 219 219 H 152 206 260 260
F 43,5 H 43,5 132 43,5 13243,5 175,543,5 175,5
43,5 219
43,5 219
43,5 219 F 219 H54 152
54 206
54 260
54 260
I 40 40 40 40 40 40 40 40 I 45 45 45 45
I 40 40 40 40 40 40 40 40 I 45 45 45 45
G J 20 10 20 10 20 10 20 10 20 10 20 1020 20
10 10 GJ 11 25 25
11 25
11 2511
J 10 10 10 10 10 10 10 10 J 11 11 11 11
H K 132 8,4 132 8,4 175,5 8,4175,5 8,4 219 8,4219 219
8,4 219
8,4 8,4 HK 11,5
152 11,5
206 11,5
260 11,5
260
K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4 K 11,5 11,5 11,5 11,5
I L 40 8,6 40 8,6 8,6 40 8,6 40 8,6 40 8,640 8,6 8,6 L 4 4 4 4
L 8,6 40 8,6 8,6 8,6 8,6 40
8,6 8,6 I 8,6 L45 454 454 45 4 4
M 165 165 165 165 165 165 165 165 M 162 162 162 162
J 10 M 10 165 10 165 10 165 10 165 10 16510 16501 165 J 165 M11 162
11 162
11 162
11 162
N 80 80 80 80 80 80 80 80 N 90 90 90 90
N 80 80 80 80 80 80 80 80 N 90 90 90 90
K A1 8,4 104 8,4 104 8,4 147,5 8,4 147,5 8,4 1918,4 1918,4 8,4
191 191 K A1 11,5
124 11,5
178 11,5
232 11,5
232
A1 104 104 147,5 147,5 191 191 191 191 A1 124 178 232 232
L A2 8,6 52 8,6 52 8,6 52 8,6 52 8,6 528,6 528,6 8,6
95,5 95,5 L A2 95,5 624 624 62
4 116
462
A2 52 52 52 52 52 52 95,5 A2 62 62 116
M B1 123 165 B1123165 166,5
123 166,5 165 210 165 210165 210 210 B1143 197 251 251
123 165 166,5 166,5 210 165
210 165
210 210 M 162
B1143 162
197 162
251 162
251
OS250 B261,5 61,5 61,5 61,5 61,5 61,5 105 105 B271,5 71,5 71,5 125,5
N 80 B261,580 61,5 80 61,5 80 61,5 80 61,580 61,580 105
80 105 N B29071,5 71,5
90 71,5
90 125,5
90
22 [mm] C1
D11 140
D12 140 D13 183,5 D22 183,5 227 227 227 227 C1 160 214 268 268
C1 140 140 183,5 183,5 227 227 227 227 C1 160 214 268 268
D11
D12 A1 D12C2
D13 104 D13
D22 70 104 70 D22147,5 70 147,5 70 191 70191 70191 191
113,5 113,5 A1C2 124
80 178
80 232
80 232
134
30 A 154 154
C2 70 154 70 154 70 70 70 70 113,5 113,5 C2 80 80 80 134
154
154 154
154
A2 154
52 154 52 154 52 52 52 52 95,5 95,5 A2 62 62 62 116
99 B M00014/OS200_250_11_22
193 193 K 193
M00014/OS200_250_11_22 K 193
193
193 193
B1 193 193
123 193 123 193
166,5 166,5 210 210 210 210 B1 143 197 251 251
6,5 C 33,5 33,5 33,5 33,5
33,5
33,5 33,5
33,5
B2 33,5 61,5 33,561,5
33,5
61,5 61,5 61,5 61,5 105 105 B2 71,5 71,5 71,5 125,5
4,5 D 148,5 148,5 148,5 148,5
148,5
148,5 C1148,5
148,5 148,5
148,5 148,5
5,5 E 112,5 140 112,5 140 183,5
112,5 183,5
161 227 227 227 227 C1 160 214 268 268
112,5
112,5 112,5
112,5
C2 112,5
161
70 161
3,5 F 54 54 70 70
54 7054 70 70 113,5 113,5 C2 80 80 80 134
54 5454 25 5454 25 K 54
20 54 G M00014/OS200_250_11_22 25 25
25 2525152 2525206 25
19 25 H 260 260
152
206 260206 260260 260
40 I 45 45 45 45
45 4545 11 4545 11 45
10 45 J 11 11
11 1111 1111 11
8,4 11 K 11,5 11,5 11,5 11,5
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 134


Special connected switch fuses
Dimensional drawings

OS200_03/04_ and OS250_03/04 (BB)

OS 200: 43 OS 200: 43 75 75
OS 250: 53 OS 250: 53
20 I 20 I
OS 200:110/46 OS40,5
200:110/46 40,5
3
10,5 20 10,5K 20 K 3
OS 250:116/46 OS 250:116/46
L 6 6
J L8,4 J
8,4 8,6 5,5 D
33,5 8,6 33,5 5,5 D
*) *)
45 8,5
45 8,5
72 3
72 3
126 E
126 M C 59 E
M BackC 59 types: 144
Back connection types:
connection 144
65
65
ø11 49
*) ø11 49 A1
75 *)
M5
12,5 14 min
M5 14 min
G H 12,5 H B
F B 189...254
0:110/46 40,5 G H A H
*) OS_N3
3
0:116/46 3 F 189...254 (OXP 6X210)
6 6 A *) OS_N3 (OXP 6X210)
D 5,5 D

45
45 8,5 45 8,5 18 8,518 26,5 26,5
18 26,5

05
E E E
C 59 144138,5 144
138,5 108 108
138,5 108
144
65 65 65
49 A1 A1 B1 A1 B1 C1 B1C1 C1
14 min 14 min OS200_BB_ OS250_BB_
B B [mm] D01 B01 D02 B02 D03 B03 D04 B04 [mm] D01/B01 D02/B02 D03/B03
OS200_BB_ 220 OS250_BB_
189...254 189...254 A 89,5 89,5 133 133 176,5 176,5 220 A 99,5 153,5 207,5
OXP 6X210) [mm]
(OXP 6X210) D01 B B01 149 D02 130 B02 149 D03 130 B03 149 D04 130 B04 149 [mm] 149 B D01/B01 D02/B02
154 D03/B03
154 D04/B04
154
A 89,5 C 89,5 198,5 133 198,5 133 198,5 176,5 198,5 176,5 198,5 220198,5 220198,5 A 198,5 C 99,5 153,5
193 207,5
193 261,5
193
OS200_BB_ OS250_BB_
B 149 D 130 36,5 149 36,5 130 36,5 149 36,5 130 36,5 149 36,5 149 36,5 B 36,5 D 154 154
33,5 154
33,5 154
33,5
[mm] C
D01 B01
198,5
D02 144,5198,5
E198,5
B02 144,5198,5
D03 144,5 B03 D04 B04
198,5 144,5 198,5 144,5 198,5144,5 [mm] C
198,5144,5 D01/
144,5 E D02/193 D03/ 193
148,5D04/ 148,5
193 193
148,5
A B01 B02 B03 53,5 B04 53,5
D89,5 89,5
36,5 133 48,5 36,5
F 36,5 133 48,5176,5
36,5 48,5176,5
36,5 48,5 220
36,5 48,5 220
36,5 48,5 36,5 48,5 D 48,5 F 33,5 33,5 33,5 53,5
33,5
B E 149 144,5
130
G144,5
149
-
144,5
130
-144,5
149
43,5 144,5
130
43,5 144,5 43,5 144,5 43,5
149 149 144,5A43,5 E 99,5
43,5 G 153,5
148,5 207,5148,5 - 261,5148,5
54 54
148,5
H 48,5 20 48,5 20 48,5 20 48,5 20 48,5 20 48,5 20 48,5B 20 F 20 H
C
F
198,5
48,5
198,5 154 15453,5 154 53,525 154 53,5
25 25
53,5
G - I 198,5
-
198,5
40 43,5
198,5
40 43,5
198,5
40 43,5
198,5
40 43,5
198,5
40 43,5 40 43,5 40 G 40 I - 5445 45
54 45
54
D C 10193 193 193 193
H36,5 36,5
20 J 36,5
20 1036,5
20 1036,5
20 1036,5
20 1036,520 1036,5 20 10 20 10 H J 25 2511 251 11
25
40D 33,5 33,5 45 33,5 45
K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4 K 11,5 33,5 11,5 11,5
E I
144,5 40
144,5 40
144,5 40
144,5 40
144,5 40
144,5 144,540 144,5 40 I 45 45
L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 L 4 4 4
J 10 10 10 10 10 10 10 10E J 148,5 148,5 11 148,5 1 148,5 11 11
F 48,5 48,5 M 48,5 164,548,5 164,548,5 164,548,5 164,548,5 164,548,5 164,5 164,5 164,5 M 162 162 162
K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4F K 53,5 11,5 53,5 11,5 11,5 11,5
G - - A143,5 60,543,5 60,543,5 10443,5 10443,5 147,543,5 147,5 191 191 A1 53,5 70,5 53,5 124,5 178,5
L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 L 4 4 4 4
B179,5 79,5 123 123 166,5 166,5 210 G210 - B1 54 89,5 54 143,5 54 197,5 251,5
H M 20 164,520 20
164,5 20
164,5 20
164,5 20
164,5 20
164,5 20
164,5 164,5 M 162 162 162 162
C196,5 96,5 140 140 183,5 183,5 227 227 C1 106,5 160,5 214,5 268,5
I A140 60,540 60,5
404 104
40 104
40 147,5
40 147,5
40 40191 191H A1 25 2570,5 25124,5 25178,5 232,5
_ OS250_BB_ OS250_BB_
B179,5 79,5 M00008/OS200_250_01_04
123 123 K / M07023 166,5
166,5 210 210 I B1 89,5
45 143,5
45 45197,5 45251,5
04 J 10 10 10 10 10 10 10 01
[mm]
D04 C1D01/B01
D01/B01 B04D02/B0296,5 96,5 D02/B02
[mm] D03/B03 D03/B03
D01/B01
D04/B04
140 140 D04/B04
D02/B02 183,5D03/B03183,5 D04/B04227 227 C1 106,5 160,5 214,5
K 8,4 8,4 153,5 8,4 8,4 153,5261,5
8,4 207,58,4 8,4 8,4 J 11 11 11 11268,5
20 A
220 99,5 220 153,5A 99,5 207,5 99,5207,5
261,5 261,5
M00008/OS200_250_01_04 K / M07023 K 11,5 11,5 11,5 11,5
49 B
149 L
154 149 8,6
154B 154 8,6 154 154 8,6154
154 154 8,6 154 154
8,6 1548,6 8,6
154 8,6
8,5 C
198,5 M 198,5
193 C 193 164,5
193
164,5 193 193 193
193 164,5
164,5193 193
193164,5 193
164,5 193
164,5 164,5 L 4 4 4 4
6,5 D
36,5 A1 36,5
33,5 D 33,5 60,5
33,5
60,5 33,5 33,5 10433,5
33,5 33,5 33,5
104 33,5147,5 33,5
147,5 33,5
191 191 M 162 162 162 162
4,5 E
144,5 148,5144,5 E 148,5 148,5 148,5 148,5
148,5 148,5148,5 148,5148,5 148,5 148,5 A1 70,5 124,5 178,5 232,5
B1 79,5 79,5 123 123 166,5 166,5 210 210
8,5 F
48,5 53,5 48,5 F 53,5 53,5 53,5 53,5
53,5 53,5 53,5 53,5 53,5 53,5 53,5 B1 89,5 143,5 197,5 251,5
C1 96,5 96,5 140 140 183,5 183,5 227 227
3,5 G
43,5 - 43,5 G
54 - 54 54 54 - 54 54 54 54 54
M00008/OS200_250_01_04 K / M07023 C1 106,5 160,5 214,5 268,5
20 H
20 25 20 H
25 25 25 25 25
25 25 25 25 25 25
40 I
40 45 40 I
45 45 45 45 45
45 45 45 45 45 45
10 J
10 11 10 J1 11 11 1 11 11
11 1 11 11 11
8,4 K
8,4 11,5 8,4 K 11,5
11,5 11,5 11,5 11,5 11,5
11,5 11,5 11,5 11,5 11,5
8,6 L
8,6 4 8,6 L4 4 44 4 4 4 4 4 4 4
4,5 M
164,5 162164,5 M
162
162 162
162 162
162 162 162 162 162 162
91 A1
191 70,5 191 A1 70,5 178,5 124,5 232,5
124,5 70,5178,5 124,5232,5 178,5 232,5
B1 143,5 89,5 197,5
89,5 210 B1143,5 251,5
89,5197,5 143,5251,5 197,5 251,5
C1 160,5 106,5 214,5
106,5 227 C1160,5 268,5
106,5214,5 160,5268,5 214,5 268,5
135 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 136


Special connected switch fuses
Dimensional drawings

OS315_12/22_ and OS400_12/22 (BB)

mmmm 81 81
5 5 3,19
6464
in in 58,5
58,5 2,522,52 0,20 3,19
0,20
2,30
2,30 43,543,5
5 5
2525 7,57,5 10,810,8 55,8/130,9
55,8/130,9 0,200,20
1,711,71
0,98
0,98 0,30
0,30 0,43 2,20/5,15
2,20/5,15
M5M5 0,43 40 40 12 1245 45
3/16
3/16 1,571,57 0,470,47
1,771,77
*) *)
5 5
0,20
0,20 B B
193193 94 94
7,60
7,60 BackBack
connection types:
connection types: 3,703,70
230230 95 95
9,069,06 3,743,74
ø11 ø11 45 45
*) *) 0,430,43
38 38
1,771,77
11,511,5 12,5 12,5 1,50 1,50 minmin
20 20
0,450,45 0,490,49
25 25
0,790,79
117117 6464 0,980,98 A A
4,61 2,52
4,61 2,52 230...325
230...325
C C 9,06...12,80 (OXP 12x250)
D D *) OS_N3
*) OS_N3 9,06...12,80 (OXP 12x250)
5
77

05
A2 A2 B2 A2 B2 C2 B2 C2 C2
B
164 164159 164159128 159128 128
6,46 6,466,26 6,46
6,265,04 6,26
5,04 5,04
95
3,74 A1 A1 B1 A1 B1 C1 B1 C1 C1

OS315-400_BB_ OS400_BB_
OS315-400_BB_ OS400_BB_
[mm] B11 B12 B13 B21 B22 [mm] D11 D12 D13 D21 D22
[mm] B11 B12 B13 B21 B22 [mm] D11 D12 D13 D21 D22
A 176 176 176 176 176 A 193 193 193 193 193
A 176 176 176 176 176 A 193 193 193 193 193
B 194 OS315-400_BB_
194 194 194 194 B 166 166 166
OS400_BB_ 166 166
B 194 194 194 194 194 B 166 166 166 166 166
C 140 140 140 204 204 C 140 140 140 204 204
C 140 140 140 204 204 C
190 [mm] 254 B11 318 B12 B13 B21 B22 190 140 140
[mm] 318 140
D11254 204
D12 204
D13 D21 D22
50)
D 254 318 D 254 318
D 190 254 318 254 318 D 190 254 318 254 318
A 176 176 176 176 176 A 193 193 193 193 193
OS315_BB_ OS400_BB_
OS315_BB_ OS400_BB_
[mm] B11 B B12 194 B21 194 B22 194 B13 194 [mm] 194 B
B11/D11 166
B12/D12 166 166
B21/D21 166 166
B22/D22 B13/D13
[mm] B11 B12 B21 B22 B13 [mm] B11/D11 B12/D12 B21/D21 B22/D22 B13/D13
A1 163 227 227 291 291 A1 163 227 227 291 291
A1 C
163 227140 140
227 140
291 204
291 204
A1 C 163 140 227140 140 227 204 204 291 291
A2 81,5 81,5 145,5 145,5 81,5 A2 81,5 81,5 145,5 145,5 81,5
A2 81,5 81,5 145,5 145,5 81,5 A2 81,5 81,5 145,5 145,5 81,5
B1181 245 D 245 190 309 254 309 318 254 B1 318 181 D 245 190 254245 318 254
309 318 309
B1181 245 245 309 309 B1 181 245 245 309 309
B290,5 90,5 154,5 154,5 90,5 B2 90,5 90,5 154,5 154,5 90,5
B290,5 90,5 154,5 154,5 90,5 B2 90,5 90,5 154,5 154,5 90,5
C1199 263 263 327 327 C1 199 263 263 327 327
C1199 263 263 327 327 C1 199 263 263 327 327
C299,5 99,5 163,5 163,5 99,5 C2 99,5 99,5 163,5 163,5 99,5
C299,5 99,5 163,5 163,5 99,5 C2 99,5 99,5 163,5 163,5 99,5
C000011/OS315-400_11_22 D / M07024
C000011/OS315-400_11_22 D / M07024 OS400_BB_
OS315_BB_
[mm] B11 B12 B21 B22 B13 [mm] B11/ B12/ B21/ B22/ B13/
D11 D12 D21 D22 D13
A1 163 227 227 291 291
A1 163 227 227 291 291
A2 81,5 81,5 145,5 145,5 81,5
A2 81,5 81,5 145,5 145,5 81,5
B1 181 245 245 309 309
B1 181 245 245 309 309
B2 90,5 90,5 154,5 154,5 90,5
B2 90,5 90,5 154,5 154,5 90,5
C1 199 263 263 327 327
C1 199 263 263 327 327
C2 99,5 99,5 163,5 163,5 99,5
C2 99,5 99,5 163,5 163,5 99,5
C000011/OS315-400_11_DD D/M07024

B13/D13
137 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses
Dimensional drawings

OS315_03/04_ and OS400_03/04 (BB)

mm mm 5581 81
in in 0,20
0,20
58,5 58,5 3,19 3,19
28 28
1,10 1,102,30 2,30 10,8 10,8 55,8/130,9 43,5 543,5 5
55,8/130,9
0,43 0,43
11,5 11,5
7,5 7,5 2,20/5,15 1,71 0,20
2,20/5,15 1,71 0,20
M5 M50,45 0,45
0,30 0,30 12 4512 45
3/16 3/16 40 40 1,77 1,77
1,56 1,560,47 0,47
*) *) 17 17 26 26
82 82 5 5 0,67 0,67 1,02 1,0
3,23 3,23 0,20 0,20
193 193 C C
140 140 7,60 7,60 94 94 164 164 159 159
5,51 5,51 230 3,70
230 3,70 6,46 6,46 6,26 6,26
9,06 9,06
Back connection types:
Back connection types:
95 95
45 45 3,74 3,74
A1 A1 B1
*) *) 1,77 1,77
ø11 ø11 min 20 min 20
81 5 81
0,43 0,43
38 38 0,79 0,79
3,19 0,20 3,19 75,5 64
75,5 64 25 25 12,5
0,49
12,51,50
0,49
1,50 B B
2,97 2,52
2,97 2,520,98 0,98 25 25
43,5 5 0,98 0,98 230...325 (OXP 12x250)
230...325 (OXP 12x250)
55,8/130,9 43,5 5 A A 9,06...12,80
9,06...12,80
,71 0,20
2,20/5,15 1,71 0,20
45 *) OS_N3
*) OS_N3
12 12 45 12 45
40 40
1,561,77 0,47 1,56
0,47 1,77 0,47 1,77
17 17 26 26 35
17 35
26 35
5 0,67 1,02
0,67 1,02
0,671,38 1,38
1,02 1,38
0,20
C C C
94 164 164159 159128
164 128
159 128
230 3,70 6,46 6,46 6,26 6,26
6,46 5,04 5,04
6,26 5,04
9,06 95 95 95
on types: 3,74 3,74 3,74
45 A1 A1 B1 A1B1 C1 B1C1 C1
1,77
n 20 min 20 min 20
7938 0,79 0,79
1,50 B B
OS315 - 400_BB_
OS315 - 400_BB_ OS400_BB_OS400_BB_

12x250)(OXP 12x250)
30...325
[mm]
230...325
B01
[mm]
(OXP
B02
B01
12x250)
B03
B02 B04
B03 [mm]
B04
A319
D01
[mm] D02
D01 D03
D02 D04
D03 D04
A A127 191
127 255
191 319
255 A127 191
127 255
191 319
255 319
,80 9,06...12,80 B 9,06...12,80 B 176 B193 193 193 193
OS315 - 400_BB_ B176 176
176 176
176 176
176 OS400_BB_ 193 193 193 193
C C194 194
194 194
194 194
194 C 194 C166 166
166 166
166 166
166 166
[mm] B01 B02 B03 B04 [mm] D01 D02 D03 D04
OS315_BB_OS315_BB_ OS400_BB_OS400_BB_
A 127 191 255 319 A 127 191 255 319
[mm] B01
[mm] B02
B01 B03
B02 B04
B03 [mm]
B04 [mm] B01/D01 B01/D01B02/D02 B02/D02B03/D03 B03/D03B04/D04 B04/D04
B 176
A1 A1 176
98,5 98,5 176
162,5 176
226,5
162,5 290,5
226,5 A1B
290,5 A1 193
98,5 98,5 193
162,5 193 226,5
162,5 193
226,5 290,5 290,5
B1116,5 180,5
B1116,5 244,5
180,5 308,5
244,5 308,5 B1 116,5
B1 180,5
116,5 180,5 244,5 244,5 308,5 308,5
C 194
C1 194
134,5 198,5 194
262,5
C1134,5 198,5
194
326,5
262,5 326,5 C1C 134,5
C1
166
198,5
134,5
166
198,5 262,5
166
262,5 326,5 166
326,5

C000012 /OS315_400_01_04 D / M07025D / M07025


C000012 /OS315_400_01_04

OS315_BB_ OS400_BB_
[mm] B01 B02 B03 B04 B01/ B02/ B03/ B04/
[mm]
D01 DO2 DO3 DO4
A1 98,5 162,5 226,5 290,5
A1 98,5 162,5 226,5 290,5
B1 116,5 180,5 244,5 308,5
B1 116,5 180,5 244,5 308,5
C1 134,5 198,5 262,5 326,5
C000012 /OS315_400_01_04 D/M07025
C1 134,5 198,5 262,5 326,5

D04
319
193
166

32/D02 B03/D03
B04/D04 B04/D04
5 162,5 290,5 226,5 290,5

5 244,5 308,5

5 262,5 326,5
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 138


Special connected switch fuses
Dimensional drawings

OS125G...160GD12LR (LR)

162
142

32

45

97
63 69
28

05
185
55 90 156

56
35
122 100
35
56

ø 5,5 M6
65 44
242
M00364/OS160GD12LR_B
139 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses
Dimensional drawings

OS125G...160GD21LR (LR)

162
142

97
63
28

185
90 55 156

56
35
122 100
35
56

M6
ø 5,5
242 44
M00365/OS160GD21LR_A
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 140


Special connected switch fuses
Dimensional drawings

OS125G...160GD22LR (LR)

197
177

97 63 69
28

156
220 7 44
90 90

05
56
35
100
150
35
56
35
ø 5,5

M6
277
M00366/OS160GD22LR_A
141 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses
Dimensional drawings

OS125G...160GB12LR (LR)

162
142

97
63 69
28

185
55 90 141

56
35
122 118
35
56

ø 5,5 M6
242 44
M00361/OS160GB12LR_A
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 142


Special connected switch fuses
Dimensional drawings

G
OS125G...160G_21LR + OSS160G 3LS
T

101

228 193 ø6

56

05
122

56

438
143 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses
Dimensional drawings

G
OS125G...160G_22LR + OSS160G 4LS
T

101

228 228 Ø6

56 61

91 96

473
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 14 4


Special connected switch fuses
Dimensional drawings

OS200B12_ and OS250_12_ (LR)

OS200B...250_LR, 3-pole
OS200B12LR
OS250B12LR
OS250D12LR
M00120/OS250_12BL-BR B/
M07026

36

65 45
36
101,5 155,5
65 45
(OXP 6X210)

Back right
101,5 155,5
184
218...283

(OXP 6X210)

Back right
5
Back left 184
218...283

108

05
59,5
5
Back left 25,5
108
25 12,5 50 59,5
25,5 11
45 45 54
25
12,5 50
252 11 306
151 206
121,5 45 45 54175,5
252 94 148 306
M8 151 79,5 133,5
206
45 121,5 175,5
94 148
M8 42,5 25 79,5 133,5
45 67,5 50
148,5
42,5 150 25
3 67,5 50
148,5 67,5 11 50
42,5 150
3
21,6 34,3 67,5 11 11,5 4 6 50
85

42,5 11
3 105 25 53
69,621,6 34,3 11,5 45 45 54 4 6
85

108 137 191 11


3 105 149,5 25 203,5
53
69,6 53
45 45 54
108 137 191
149,5 203,5
53
145 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses
Dimensional drawings

OS200B21_ and OS250_21_ (LR)

OS200B...250_LR, 3-pole
OS200B21LR
OS250B21LR
OS250D21LR
M00119/OS250_21BD-BR B/
M07027

36

65 45
36
155,5 101,5
65 45
(OXP 6X210)

BR 155,5 101,5
184
218...283
(OXP 6X210)

BR
BL 5 184
218...283

108
BL 559,5
25,5
108
25 12,5 50 59,5
25,5 11
54 45 45
25 12,5 50
306 11 252
205 54 45 45 151
175,5 121,5
306 148 94 252
M8 205 133,5 79,5 151
45 175,5 121,5
148 94
M8 42,5 25 133,5 79,5
45 67,5
148,5
42,5 150
3 25
67,5
148,5 67,5 11 50
42,5 150
3
21,6 34,3 67,5 11 11,5 6 50
85

42,5 4
3 105 11 25 53
69,6
21,6 34,3 54 45 45 6
11,5
85

108 191 4 137


3 105 203,5
11 25 149,5
53
69,6 54 45 5345
108 191 137
203,5 149,5
53
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 146


Special connected switch fuses
Dimensional drawings

OS315B12_ and OS400_12_ (LR)

OS315B...400_LR
A B
OS315B12LR 201 194
OS400B12LR 201 194
OS400D12LR 218 166
M00130/OS400_12BL-BR C/M070028

36

95
36 45
120,5 184,5
95 45
12X250)

120,5 184,5
BR
255...350
12X250)

A
(OXP (OXP

BR

05
255...350

BL A
5
BL 110
5
61,5
28
29 110
20 61,5
25 12,5 43 11 50
28
12,5 58,5 20
58,5 64
29
25 12,5 43 11 50
271,5 12,5 335,5
169 58,5 58,5 64 233
47 140 204
271,5 112 176 335,5
M8 21 99 163 5,5
169 233
47 23 140 204
112 176
M8 21 25 99 163 5,5
69 50
23
B 150 25
69 50
9
5 50
B 150 69 11
9 23
5 50
40 69 11 7,5
51
23 104 25
11,5
5 126 64
68,7
40 51 7,5 58,5 58,5 64
155,5
11,5 104 25220
5 110 126 168 64 232
68,7 6458,5 58,5 64
155,5 220
110 168 232
64
147 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Special connected switch fuses
Dimensional drawings

OS315B21_ and OS400_21_ (LR)

OS315B...400_LR
A B
OS315B21LR 201 194
OS400B21LR 201 194
OS400D21LR 218 166
M00127/OS400_21BL-BR C/M070029

36
36
95 45
95 45
184,5 120,5
184,5 120,5
12X250)
12X250)

BR A
255...350

BR A
255...350
(OXP
(OXP

BL
BL 5
5
110
61,5 110
28 61,5
28 29 20 11 50
29 25 20
12,5 11 50
25
12,5 64 58,5 58,5
64 58,5 58,5
335 271,5
47 335204 233 140
169 271,5
233176 112 169
47
M8 21 204 163 140
99
176 112
M8 21 23 163 99
B 23 69 25 50
B 69 25 50
150
9 150
9 5 69 50
5 69 11 50
23
23 11
40 104 5,5
5 51 7,5
40 104 64 5,5
5 51 7,5
11,5 25
68,7 126 64
11,5 25
64 58,5 58,5
68,7 126 220 155,5
64 58,5 58,5
110 220 232 168 155,5
64
110 232 168
64
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 148


Special connected switch fuses
Dimensional drawings

OS315B22_N2 and OS400_22_N2 (LR)

OS315B...400_LR
A B
OS315B22LR 201 194
OS400B22LR 201 194
OS400D22LR 218 166
M00126/OS400_22BL-BRN2 C/M07030

36
36
95 45
95 45
183,5 183,5
183,5 183,5
12X250)
12X250)

BR A
255...350

BR A
255...350
(OXP
(OXP

BL
BL 5

05
5
110
61,5 110
28 61,5
28
29 20
29 20 25 11 50
12,5 25 11 50
12,5
64 58,5 58,5 64
64 58,5 58,5 64

334 334
334 233 233 334
68,7 233 203,5 203,5 233
5 203,5 176,5 176,5 203,5
68,7 153,5 176,5 176,5153,5
5 153,5 153,5
22 30 5,5
22 30 5,5
31 33
31 33 80
85 80
72,5 50
75 85 72,5
75 50
B
B 9 50
9 5 80 50
5 125
125 85 8025 50
33,5 85 25 50
33,5
41,1 122,5 11 7,5 104
41,1 122,5 11 11 7,5 104 64
64 25
M8 47 11
11,5 25
47 116,2 11,5 64 58,5 58,5
M8 116,2 219 64 58,5 58,5 219
110 219 231,5 219 231,5
110 231,5 64 231,5
64
149 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motorized switch fuses
Dimensional drawings

OSM32...63_M_

OSM32-63_M_
[mm] D3 D4 B3 B4
A 23,5 23,5 23,5 23,5
A1 122 122 122 122
A2 187,5 211 187,5 211
B 229 252,5 229 252,5
C 100 100 100 100
D 136,5 136,5 124,5 124,5
M00293/OSM32-63-M A

OSM32-63_M_
OSM32-63_M_
[mm] D3 D4 B3 B4 [mm] D3 D4 B3 B4
A 23,5 23,5 23,5 23,5 A 23,5 23,5 23,5 23,5
A1 122 122 122 122 A1 122 122 122 122
A2 187,5 211 187,5 211 A2 187,5 211 187,5 211
B 229 252,5 229 252,5 B 229 252,5 229 252,5

C 100 100 100 100 C 100 100 100 100


D 136,5 136,5 124,5 124,5
D 136,5 136,5 124,5 124,5
M00293 / OSM32-63-M A
M00293 / OSM32-63-M A

OSM32-63_M_
[mm] D3 D4 B3 B4
A 23,5 23,5 23,5 23,5
A1 122 122 122 122
A2 187,5 211 187,5 211
B 229 252,5 229 252,5
C 100 100 100 100
D 136,5 136,5 124,5 124,5

M00293 / OSM32-63-M A
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 150


Motorized switch fuses
Dimensional drawings

OSM100...160_M_

05
OSM100-160_M_
OSM100-160_M-
[mm] D/F3 D/F4 B3 B4
A [mm] 35 D/F335 D/F4 35 B3 35 B4
A1 A 122 35
122 35122 35 122 35
A2 A1 272 307
122 122272 122 307 122
B 290 325 290 325
A2 272 307 272 307
C 100 100 118 188
D B 146 290
146 325
130,5 290130,5 325
C/ OSM100-160-M A
M00294 100 100 118 188
D 146 146 130,5 130,5
M00294/OSM100-160-M A
151 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motorized switch fuses
Dimensional drawings

OSM200_M_

OSM200_M_
[mm] B3 B4 D3 D4
OSM200_M_
A 43,5 43,5 43,5 43,5
[mm] B3 B4 D3 D4
A1 118 118 118 118
A 43,5 43,5 43,5 43,5
A2 301,5 345 301,5 345
A1 118 118 118 118
B 323,5 367 323,5 367
A2 301,5 345 301,5 345
C B 144,5
323,5 144,5 144,5
367 144,5
323,5 367
DC 132
144,5 132 144,5 151 151
144,5 144,5
M001997
D OSM200-M
132B 132 151 151

M001997 OSM200-M B
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 152


Motorized switch fuses
Dimensional drawings

OSM250_M_

05
OSM250_M_
OSM250_M_
[mm] D3/B3 D4/B4
[mm] D3/B3 D4/B4
A 54 54
A 54 54
A1 118 118
A1 118 118
A2 332 386
A2 332 386
B 354 408
B 354 408
C 148,5 148,5
C 148,5 148,5
DD 156
156 156 156
M00198 / OSM250-M B
M00198 / OSM250-M B
153 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motorized switch fuses
Dimensional drawings

OSM315...400_M_

OSM315_M_ OSM400_M_
[mm] B3 B4 [mm] B3 B4 D3 D4
OSM315_M_
A 64 64 A OSM400_M_
64 64 64 64
A1 136 136 A1 136
[mm] B3 136 B4 136 D3 136
D4
[mm] B3 B4
A2 382 446 A2 382 446 382 446
A 64 64 A 64 64 64 64
B 404 468 B 404 468 404 468
A1C 136
194 136
194 C A1 194 136 194 136 166 136 136
166
A2D 178,5
382 178,5
446 D A2178,5 178,5
382 446 196,5 382 196,5
446
B M00199/ OSM315-400-M
404 C 468 B 404 468 404 468
C 194 194 C 194 194 166 166
D 178,5 178,5 D 178,5 178,5 196,5 196,5
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 154


Motorized switch fuses
Dimensional drawings

OSM630...800_M_

05
OSM630-800_M_
[mm] D3/B3 D4/B4
A 88 OSM630-800_M_
88
[mm] D3/B3 D4/B4
A1 180 180
A 88 88
A2 465,5 553,5
A1 180 180
B 486,5 A2 574,5465,5 553,5
B 486,5 574,5
M00206 / OSM639-800-M B
M00206 / OSM639-800-M B
155 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Motorized switch fuses
Dimensional drawings

OSM1250_M_

OSM1250_M_
[mm] B3/D3 B4/D4
A 110 110
A1 OSM1250_M_230 230
OSM1250_M_
A2 [mm] B3/D3
569,5
[mm]
B4/D4
679,5
B3/D3 B4/D4
A 110 110
B A1 599,5
230A
709,5
110
230 110

M00238
A2 569,5A1
/ OSM1250-M 230
C679,5 230

B 599,5A2 569,5
709,5 679,5
B 599,5 709,5
M00238 / OSM1250-M C
M00238 / OSM1250-M C
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 156


Accessories for switch fuses 20…1250 A
Dimensional drawings for handles

Plastic handles
36 45
Handle type [mm] Shaft diameter B Length L
Ø66
OH_45J6 6 45
OH_65J6 6 65
B
OH_95J12 12 95
OH_125J12 12 125
OH_145J12 12 145
OH_175J12 12 175
OH_275J12 12 275 L

Handle type [mm] Length L


OH_274J12 274
OH_330J12 330

Door drilling for OH_ handles:


80 70
54
Ø31 Ø5

05
ON
Ø69,4

L
OFF
45°

53

Plastic handles, type OHB

Handle type [mm] Length L


OHB150J12P 300
OHB200J12P 400 80 71
54

Door drilling for OHB_ handles:


Ø69,4
Ø31 Ø5
L

45°
53
53
157 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for switch fuses 20…1250 A
Dimensional drawings for handles

Stainless steel handles

37 51
Handle type B shaft diameter [mm] Lenght L [mm] Ø69
OHM45L6 6 45
OHM65L6 6 65 B
OHM125L12 12 125
OHM175L12 12 175
OHM275L12 12 275

Door drilling for OHM_ handles: L

Ø31 Ø5

45°
53
53

Minimum distance L between the hinge and the rotating shaft

Sizes [A] Length L [mm] Handle type L


30...250 60 OH_65J6
315...400 95 OH_95J12
630...800 150 OH_125J12, OH_145J12
630...800 175 OH_175J12
630...800 275 OH_275J12
1200...1250 274 OH_274J12
1200...1250 330 OH_330J12

Hinge

Shaft
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 158


Accessories for switch fuses 20…1250 A
Dimensional drawings for handles

Plastic handles

36 45
Handle type [mm] Shaft diameter B Length L
OH_45J6 6 45 Ø66
OH_65J6 6 65
OH_80J6 6 80
B
Door drilling for OHM_ handles:

Ø31 Ø5

L
1

45°
53
53

05
Minimum distance L between the hinge and the rotating shaft

L
Sizes [A] Length L [mm] Handle type
30...250 60 OH_65J6

hinge

shaft
159 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for switch fuses 20…1250 A
Dimensional drawings for conversion kits

6 and 8-pole switch fuses

OESAZW2

OETLZW9
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 160


Accessories for switch fuses 20…1250 A
Dimensional drawings for conversion kits

Change-over switch fuses

OETLZW11 OETLZW12

05
OETLZW11
OFTLZW11 OETLZW11
A 210+(0...11)x20 mm OETLZW12, 13
OFTLZW12
A 210+(0...11)x20mm
A OETLZW12 OETLZW13
210+(0...18)x20mm
DA 210+(0...18)x20 mm 210+(0...18)x20
220mm mm
B 250+(0...18)x20 mm
D 220 mm 320 mm

OTZW 25

OTZW26
A00213_B

OTZW25 A 210+(0...9)x20mm
OTZW25
A 210+(0...18)x20mm B 210+(0...9)x20mm
A 210+(0...18)x20mm
161 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Accessories for switch fuses 20…1250 A
Dimensional drawings for conversion kits

By-pass switch fuses

OETLZW13

OETLZW13
A 210+(0...18)x20mm
B 250+(0...18)x20mm
D 320mm

OETLZW12, 13
OETLZW12 OETLZW13
A 210+(0...18)x20 mm 210+(0...18)x20 mm
OTZW26 B 250+(0...18)x20 mm
D 220 mm 320 mm

OTZW26
A 210+(0...9)x20mm
B 210+(0...9)x20mm

OTZW26
ZW25 A 210+(0...9)x20mm
210+(0...18)x20mm B 210+(0...9)x20mm
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 162


Accessories for switch fuses 20…1250 A
Dimensional drawings for conversion kits

Mechanical interlock

OTZW10
S00120A

05
OETLZX3, 14, 15
OETLZW3 OETLZW14 OETLZW15
A 300 250 500
B 31 31 36

OTZW10

OTZW10
A 206
B 190
C 6
D 30
163 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 164


Switch fuses
Index

Type Order number Description Page


MCB-01 1SCA022150R5370 Auxiliary contact 76
MCB-10 1SCA022150R5110 Auxiliary contact 76
OA1G10 1SCA022353R4970 Auxiliary contact 76, 77
OA1G10AU 1SCA022436R7910 Auxiliary contact 76, 77
OA3G01 1SCA022456R7410 Auxiliary contact 76, 77
OA3G01AU 1SCA022819R5260 Auxiliary contact 76, 77
OA4B01 1SCA022276R9210 Auxiliary contact 76
OA4B10 1SCA022276R9050 Auxiliary contact 76
OA4B1C 1SCA022193R0150 Auxiliary contact 76
OESAZW2 1SCA022078R1600 Conversion kit 90
OETLZW11 1SCA022078R0030 Conversion kit 90
OETLZW12 1SCA022078R0200 Conversion kit 90
OETLZW13 1SCA022078R0460 Conversion kit 90
OETLZW14 1SCA022077R3410 Conversion kit 90
OETLZW15 1SCA022081R9340 Conversion kit 90
OETLZW3 1SCA022049R0380 Conversion kit 90
OETLZW9 1SCA022061R3300 Conversion kit 90
OETLZX95 1SCA022083R5620 Shaft extension socket 75
OEZNL1 1SCA022723R7400 Solid link 83
OEZNL10 1SCA116437R1001 Solid link 83
OEZNL8 1SCA113998R1001 Solid link 83
OEZXU 14/3 1SCA100361R1001 Terminal shroud 85
OEZXU 14/4 1SCA101082R1001 Terminal shroud 85
OEZXU 68/3 1SCA121380R1001 Terminal shroud 85
OEZXU 68/4 1SCA121379R1001 Terminal shroud 85
OFAE506 1SCA128175R1001 Fuse replacement handle 72
OFAW00 1SCA022003R9680 Solid link 83
OFAW1 1SCA022003R9760 Solid link 83

06
OFAW2 1SCA022003R9840 Solid link 83
OFAW3 1SCA022003R9920 Solid link 83
OFAW4 1SCA022842R5440 Solid link 83
OFAW4a 1SCA148430R1001 Solid link 83
OFD110EA 1SCA121775R1001 Electronic fuse monitor 92
OFD500EA 1SCA121776R1001 Electronic fuse monitor 92
OFM240 1SCA022579R1340 Electronic fuse monitor 92
OFM260 1SCA022459R8560 Electronic fuse monitor 92
OFM600 1SCA022579R1260 Electronic fuse monitor 92
OFM690 1SCA022459R8480 Electronic fuse monitor 92
OFMZX2 1SCA022475R9910 Mounting accessory 92
OFS260 1SCA022716R0180 Electronic fuse monitor 92
OFS690 1SCA022715R9920 Electronic fuse monitor 92
OGH145J12 1SCA022381R2290 Pistol handle 69
OHB125J12 1SCA022381R1560 Pistol handle 69
OHB125J12T 1SCA022652R2220 Pistol handle 69
OHB145J12 1SCA022381R2110 Pistol handle 69
OHB145J12E00S 1SCA022679R9700 Pistol handle 71
OHB145J12T 1SCA022652R2570 Pistol handle 69
OHB150J12P 1SCA022865R9430 Pistol handle 70
OHB175J12 1SCA022381R2450 Pistol handle 69
OHB175J12T 1SCA022708R0740 Pistol handle 69
OHB200J12P 1SCA022865R9510 Pistol handle 70
OHB200J12PT 1SCA106510R1001 Pistol handle 70
OHB274J12 1SCA115920R1001 Pistol handle 70
OHB274J12T 1SCA120250R1001 Pistol handle 70
OHB330J12 1SCA115922R1001 Pistol handle 70
OHB330J12T 1SCA120252R1001 Pistol handle 70
OHB4 1SCA022439R4050 Direct mount handle 72
OHB45J6 1SCA022380R8770 Pistol handle 69
OHB45J6T 1SCA109870R1001 Pistol handle 69
165 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OHB65J6 1SCA022380R9660 Pistol handle 69
OHB65J6E00S 1SCA022382R9850 Pistol handle 71
OHB65J6T 1SCA022399R8110 Pistol handle 69
OHB65J6TE00S 1SCA109016R1001 Pistol handle 71
OHB80J6 1SCA022381R0240 Pistol handle 69
OHB80J6T 1SCA022399R8290 Pistol handle 69
OHB95J12 1SCA022381R0830 Pistol handle 69
OHB95J12T 1SCA022736R1750 Pistol handle 69
OHG125J12 1SCA022381R1640 Pistol handle 69
OHG175J12 1SCA022381R2610 Pistol handle 69
OHG45J6 1SCA022380R8850 Pistol handle 69
OHG65J6 1SCA022380R9740 Pistol handle 69
OHG65J6E00S 1SCA022383R4510 Pistol handle 71
OHG65J6T 1SCA022456R9620 Pistol handle 69
OHG65J6TE00S 1SCA109014R1001 Pistol handle 71
OHG95J12 1SCA022381R0910 Pistol handle 69
OHM125L12 1SCA022739R1150 Pistol handle 70
OHM175L12 1SCA022739R1230 Pistol handle 70
OHM275L12 1SCA022832R4840 Pistol handle 70
OHM45L6 1SCA111295R1001 Pistol handle 70
OHM65L6 1SCA022739R1070 Pistol handle 70
OHU145J12T 1SCA022652R2650 Pistol handle 69
OHY125J12 1SCA022381R1720 Pistol handle 69
OHY125J12T 1SCA022652R2310 Pistol handle 69
OHY145J12 1SCA022381R2370 Pistol handle 69
OHY150J12P 1SCA101586R1001 Pistol handle 70
OHY175J12 1SCA022381R2700 Pistol handle 69
OHY200J12P 1SCA101587R1001 Pistol handle 70
OHY200J12PT 1SCA111512R1001 Pistol handle 70
OHY274J12 1SCA115919R1001 Pistol handle 70
OHY330J12 1SCA115921R1001 Pistol handle 70
OHY45J6 1SCA022380R8930 Pistol handle 69
OHY65J6 1SCA022380R9820 Pistol handle 69
OHY65J6E00S 1SCA022382R9930 Pistol handle 71
OHY65J6T 1SCA022456R9540 Pistol handle 69
OHY65J6TE00S 1SCA022688R0140 Pistol handle 71
OHY95J12 1SCA022381R1050 Pistol handle 69
OHY95J12T 1SCA022736R1910 Pistol handle 69
OHZX14 1SCA022851R6590 Pistol handle 71
OS100GB02 1SCA116793R1001 Switch fuse 40
OS100GB02P 1SCA116723R1001 Switch fuse 40
OS100GB03 1SCA116975R1001 Switch fuse 40
OS100GB03-42 1SCA128216R1001 Switch fuse 44
OS100GB03K 1SCA116747R1001 Switch fuse 40
OS100GB03N3 1SCA125530R1001 Switch fuse 40
OS100GB03N3-42 1SCA129906R1001 Switch fuse 44
OS100GB03N3P 1SCA125531R1001 Switch fuse 40
OS100GB03N3P-42 1SCA129907R1001 Switch fuse 44
OS100GB03P 1SCA114613R1001 Switch fuse 40
OS100GB03P-42 1SCA128217R1001 Switch fuse 44
OS100GB04N1 1SCA116976R1001 Switch fuse 40
OS100GB04N1K 1SCA116748R1001 Switch fuse 40
OS100GB04N1P 1SCA114614R1001 Switch fuse 40
OS100GBS30 1SCA116758R1001 Switch fuse 40
OS100GBS30P 1SCA114656R1001 Switch fuse 40
OS100GBS40N1 1SCA116759R1001 Switch fuse 40
OS100GBS40N1P 1SCA114657R1001 Switch fuse 40
OS100GJ02 1SCA121932R1001 Fusible disconnect switch 59
OS100GJ02K 1SCA125031R1001 Fusible disconnect switch 59
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 166


Switch fuses
Index

Type Order number Description Page


OS100GJ02P 1SCA121933R1001 Fusible disconnect switch 59
OS100GJ03 1SCA115436R1001 Fusible disconnect switch 59
OS100GJ03K 1SCA121957R1001 Fusible disconnect switch 59
OS100GJ03P 1SCA114639R1001 Fusible disconnect switch 59
OS100GJ04F 1SCA115438R1001 Fusible disconnect switch 59
OS100GJ04FK 1SCA122093R1001 Fusible disconnect switch 59
OS100GJ04FP 1SCA115439R1001 Fusible disconnect switch 59
OS100GJS30 1SCA115971R1001 Fusible disconnect switch 59
OS100GJS30K 1SCA115942R1001 Fusible disconnect switch 59
OS100GJS40F 1SCA115972R1001 Fusible disconnect switch 59
OS100GJS40FK 1SCA115943R1001 Fusible disconnect switch 59
OS1200L02 1SCA116924R1001 Fusible disconnect switch 63
OS1200L02P 1SCA116925R1001 Fusible disconnect switch 63
OS1200L03 1SCA105467R1001 Fusible disconnect switch 63
OS1200L03P 1SCA105468R1001 Fusible disconnect switch 63
OS1200L04F 1SCA105465R1001 Fusible disconnect switch 63
OS1200L04FP 1SCA105466R1001 Fusible disconnect switch 63
OS1250B02 1SCA114069R1001 Switch fuse 51
OS1250B02P 1SCA114070R1001 Switch fuse 51
OS1250B03 1SCA105249R1001 Switch fuse 51
OS1250B03K 1SCA108715R1001 Switch fuse 51
OS1250B03N3 1SCA127485R1001 Switch fuse 51
OS1250B03N3P 1SCA107936R1001 Switch fuse 51
OS1250B03P 1SCA105250R1001 Switch fuse 51
OS1250B04F 1SCA105257R1001 Switch fuse 51
OS1250B04FP 1SCA105258R1001 Switch fuse 51
OS1250D02 1SCA114045R1001 Switch fuse 34
OS1250D02P 1SCA114051R1001 Switch fuse 34

06
OS1250D03 1SCA105474R1001 Switch fuse 34
OS1250D03K 1SCA108718R1001 Switch fuse 34
OS1250D03P 1SCA105475R1001 Switch fuse 34
OS1250D04F 1SCA105472R1001 Switch fuse 34
OS1250D04FK 1SCA113109R1001 Switch fuse 34
OS1250D04FP 1SCA105473R1001 Switch fuse 34
OS1250D04N2 1SCA105247R1001 Switch fuse 34
OS1250D04N2K 1SCA108719R1001 Switch fuse 34
OS1250D04N2P 1SCA105248R1001 Switch fuse 34
OS1250DA02 1SCA114058R1001 Switch fuse 34
OS1250DA02P 1SCA114059R1001 Switch fuse 34
OS1250DA03 1SCA105165R1001 Switch fuse 34
OS1250DA03K 1SCA108720R1001 Switch fuse 34
OS1250DA03P 1SCA105238R1001 Switch fuse 34
OS1250DA04F 1SCA105239R1001 Switch fuse 34
OS1250DA04FP 1SCA105240R1001 Switch fuse 34
OS1250DA04N2 1SCA105242R1001 Switch fuse 34
OS1250DA04N2K 1SCA108721R1001 Switch fuse 34
OS1250DA04N2P 1SCA105243R1001 Switch fuse 34
OS125GB02 1SCA116794R1001 Switch fuse 41
OS125GB02P 1SCA116724R1001 Switch fuse 41
OS125GB03 1SCA115633R1001 Switch fuse 41
OS125GB03-42 1SCA128214R1001 Switch fuse 44
OS125GB03BB 1SCA120782R1001 Special connected switch fuse 52
OS125GB03BBP 1SCA120783R1001 Special connected switch fuse 52
OS125GB03K 1SCA116751R1001 Switch fuse 41
OS125GB03N3 1SCA122007R1001 Switch fuse 41
OS125GB03N3-42 1SCA129911R1001 Switch fuse 44
OS125GB03N3P 1SCA122008R1001 Switch fuse 41
OS125GB03N3P-42 1SCA129912R1001 Switch fuse 44
OS125GB03P 1SCA115634R1001 Switch fuse 41
167 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OS125GB03P-42 1SCA128215R1001 Switch fuse 44
OS125GB04BBN2 1SCA120784R1001 Special connected switch fuse 52
OS125GB04BBN2P 1SCA120785R1001 Special connected switch fuse 52
OS125GB04N1 1SCA115900R1001 Switch fuse 41
OS125GB04N1K 1SCA116752R1001 Switch fuse 41
OS125GB04N1P 1SCA115901R1001 Switch fuse 41
OS125GB12LR 1SCA120257R1001 Special connected switch fuse 52
OS125GB12LRP 1SCA120258R1001 Special connected switch fuse 52
OS125GB21LR 1SCA120259R1001 Special connected switch fuse 52
OS125GB21LRP 1SCA120261R1001 Special connected switch fuse 52
OS125GB22LR 1SCA120264R1001 Special connected switch fuse 52
OS125GB22LRP 1SCA120265R1001 Special connected switch fuse 52
OS125GBS30 1SCA116048R1001 Switch fuse 41
OS125GBS30K 1SCA116400R1001 Switch fuse 41
OS125GBS30P 1SCA114658R1001 Switch fuse 41
OS125GBS40N1 1SCA115959R1001 Switch fuse 41
OS125GBS40N1K 1SCA115926R1001 Switch fuse 41
OS125GBS40N1P 1SCA114659R1001 Switch fuse 41
OS125GD02 1SCA116873R1001 Switch fuse 27
OS125GD02K 1SCA122908R1001 Switch fuse 27
OS125GD02P 1SCA116716R1001 Switch fuse 27
OS125GD03 1SCA115638R1001 Switch fuse 27
OS125GD03BB 1SCA120801R1001 Special connected switch fuse 35
OS125GD03BBP 1SCA120802R1001 Special connected switch fuse 35
OS125GD03K 1SCA116878R1001 Switch fuse 27
OS125GD03P 1SCA115639R1001 Switch fuse 27
OS125GD04BBN2 1SCA120805R1001 Special connected switch fuse 35
OS125GD04BBN2P 1SCA120806R1001 Special connected switch fuse 35
OS125GD04F 1SCA115685R1001 Switch fuse 27
OS125GD04FK 1SCA116741R1001 Switch fuse 27
OS125GD04FP 1SCA115686R1001 Switch fuse 27
OS125GD04N2 1SCA115876R1001 Switch fuse 27
OS125GD04N2K 1SCA116740R1001 Switch fuse 27
OS125GD04N2P 1SCA115877R1001 Switch fuse 27
OS125GD12LR 1SCA120253R1001 Special connected switch fuse 35
OS125GD12LRP 1SCA120062R1001 Special connected switch fuse 35
OS125GD21LR 1SCA120319R1001 Special connected switch fuse 35
OS125GD21LRP 1SCA120255R1001 Special connected switch fuse 35
OS125GD22LR 1SCA120262R1001 Special connected switch fuse 35
OS125GD22LRP 1SCA120263R1001 Special connected switch fuse 35
OS125GDS30 1SCA115966R1001 Switch fuse 27
OS125GDS30K 1SCA115933R1001 Switch fuse 27
OS125GDS40F 1SCA116756R1001 Switch fuse 27
OS125GDS40N2 1SCA115967R1001 Switch fuse 27
OS125GDS40N2K 1SCA115934R1001 Switch fuse 27
OS125GF02 1SCA116852R1001 Switch fuse 56
OS125GF02P 1SCA116727R1001 Switch fuse 56
OS125GF03 1SCA115601R1001 Switch fuse 56
OS125GF03P 1SCA115602R1001 Switch fuse 56
OS125GF04F 1SCA115605R1001 Switch fuse 56
OS125GF04FP 1SCA115606R1001 Switch fuse 56
OS125GFS30 1SCA115973R1001 Switch fuse 56
OS125GFS30K 1SCA115944R1001 Switch fuse 56
OS125GFS40F 1SCA115975R1001 Switch fuse 56
OS125GFS40FK 1SCA115946R1001 Switch fuse 56
OS160GB02 1SCA116795R1001 Switch fuse 42
OS160GB02P 1SCA116725R1001 Switch fuse 42
OS160GB03 1SCA115412R1001 Switch fuse 42
OS160GB03-42 1SCA128212R1001 Switch fuse 44
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 168


Switch fuses
Index

Type Order number Description Page


OS160GB03BB 1SCA120656R1001 Special connected switch fuse 52
OS160GB03BBP 1SCA120657R1001 Special connected switch fuse 52
OS160GB03K 1SCA116753R1001 Switch fuse 42
OS160GB03N3 1SCA122009R1001 Switch fuse 42
OS160GB03N3-42 1SCA129915R1001 Switch fuse 44
OS160GB03N3P 1SCA122010R1001 Switch fuse 42
OS160GB03N3P-42 1SCA129916R1001 Switch fuse 44
OS160GB03P 1SCA115413R1001 Switch fuse 42
OS160GB03P-42 1SCA128213R1001 Switch fuse 44
OS160GB04BBN2 1SCA120664R1001 Special connected switch fuse 52
OS160GB04BBN2P 1SCA120665R1001 Special connected switch fuse 52
OS160GB04F 1SCA115418R1001 Switch fuse 42
OS160GB04FP 1SCA115419R1001 Switch fuse 42
OS160GB04N1 1SCA115895R1001 Switch fuse 42
OS160GB04N1K 1SCA116754R1001 Switch fuse 42
OS160GB04N1P 1SCA115896R1001 Switch fuse 42
OS160GB12LR 1SCA123716R1001 Special connected switch fuse 52
OS160GB12LRP 1SCA120271R1001 Special connected switch fuse 52
OS160GB21LR 1SCA120272R1001 Special connected switch fuse 52
OS160GB21LRP 1SCA120273R1001 Special connected switch fuse 52
OS160GB22LR 1SCA120276R1001 Special connected switch fuse 52
OS160GB22LRP 1SCA120277R1001 Special connected switch fuse 52
OS160GBS30 1SCA115960R1001 Switch fuse 42
OS160GBS30K 1SCA115927R1001 Switch fuse 42
OS160GBS30P 1SCA114660R1001 Switch fuse 42
OS160GBS40N1 1SCA115961R1001 Switch fuse 42
OS160GBS40N1K 1SCA115928R1001 Switch fuse 42
OS160GBS40N1P 1SCA114661R1001 Switch fuse 42

06
OS160GD02 1SCA116778R1001 Switch fuse 28
OS160GD02K 1SCA122910R1001 Switch fuse 28
OS160GD02P 1SCA116717R1001 Switch fuse 28
OS160GD03 1SCA114221R1001 Switch fuse 28
OS160GD03BB 1SCA120654R1001 Special connected switch fuse 35
OS160GD03BBP 1SCA120655R1001 Special connected switch fuse 35
OS160GD03K 1SCA116742R1001 Switch fuse 28
OS160GD03P 1SCA115399R1001 Switch fuse 28
OS160GD04BBN2 1SCA120660R1001 Special connected switch fuse 35
OS160GD04BBN2P 1SCA120661R1001 Special connected switch fuse 35
OS160GD04F 1SCA115401R1001 Switch fuse 28
OS160GD04FK 1SCA116880R1001 Switch fuse 28
OS160GD04FP 1SCA115402R1001 Switch fuse 28
OS160GD04N2 1SCA115881R1001 Switch fuse 28
OS160GD04N2K 1SCA116743R1001 Switch fuse 28
OS160GD04N2P 1SCA115882R1001 Switch fuse 28
OS160GD12LR 1SCA120266R1001 Special connected switch fuse 35
OS160GD12LRP 1SCA120267R1001 Special connected switch fuse 35
OS160GD21LR 1SCA120268R1001 Special connected switch fuse 35
OS160GD21LRP 1SCA120294R1001 Special connected switch fuse 35
OS160GD22LR 1SCA120274R1001 Special connected switch fuse 35
OS160GD22LRP 1SCA120275R1001 Special connected switch fuse 35
OS160GDS30 1SCA115968R1001 Switch fuse 28
OS160GDS30K 1SCA115935R1001 Switch fuse 28
OS160GDS40F 1SCA116757R1001 Switch fuse 28
OS160GDS40N2 1SCA115969R1001 Switch fuse 28
OS160GDS40N2K 1SCA115939R1001 Switch fuse 28
OS200B02 1SCA022769R7660 Switch fuse 45
OS200B02P 1SCA022769R7820 Switch fuse 45
OS200B03 1SCA022717R3410 Switch fuse 45
OS200B03BB 1SCA102083R1001 Special connected switch fuse 52
169 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OS200B03BBP 1SCA102082R1001 Special connected switch fuse 52
OS200B03K 1SCA022763R6950 Switch fuse 45
OS200B03N3 1SCA022750R0540 Switch fuse 45
OS200B03N3P 1SCA022750R0620 Switch fuse 45
OS200B03P 1SCA022709R9330 Switch fuse 45
OS200B04BBN2 1SCA102137R1001 Special connected switch fuse 52
OS200B04BBN2P 1SCA102123R1001 Special connected switch fuse 52
OS200B04F 1SCA123706R1001 Switch fuse 45
OS200B04FP 1SCA123704R1001 Switch fuse 45
OS200BS30 1SCA022870R7770 Switch fuse 45
OS200BS30K 1SCA022870R7850 Switch fuse 45
OS200BS40F 1SCA022870R7930 Switch fuse 45
OS200BS40FK 1SCA022870R8070 Switch fuse 45
OS200D02 1SCA022759R9140 Switch fuse 29
OS200D02P 1SCA022759R9220 Switch fuse 29
OS200D03 1SCA022715R2240 Switch fuse 29
OS200D03BB 1SCA102151R1001 Special connected switch fuse 36
OS200D03BBP 1SCA102150R1001 Special connected switch fuse 36
OS200D03K 1SCA022764R7130 Switch fuse 29
OS200D03P 1SCA022709R9500 Switch fuse 29
OS200D04BBN2 1SCA102146R1001 Special connected switch fuse 36
OS200D04BBN2P 1SCA102139R1001 Special connected switch fuse 36
OS200D04F 1SCA022725R8230 Switch fuse 29
OS200D04FK 1SCA022783R1220 Switch fuse 29
OS200D04FP 1SCA022725R4750 Switch fuse 29
OS200D04N2 1SCA022717R3670 Switch fuse 29
OS200D04N2K 1SCA022768R7430 Switch fuse 29
OS200D04N2P 1SCA022709R9680 Switch fuse 29
OS200DS30 1SCA022871R1370 Switch fuse 29
OS200DS30K 1SCA022871R1450 Switch fuse 29
OS200DS40F 1SCA022871R1530 Switch fuse 29
OS200DS40FK 1SCA022871R1610 Switch fuse 29
OS200DS40N2 1SCA022871R1700 Switch fuse 29
OS200DS40N2K 1SCA022871R1880 Switch fuse 29
OS200DZ03 1SCA022797R3520 Switch fuse 29
OS200DZ03P 1SCA022797R3440 Switch fuse 29
OS200DZ04N2 1SCA022819R4110 Switch fuse 29
OS200DZ04N2P 1SCA022820R9230 Switch fuse 29
OS200GB03 1SCA123903R1001 Switch fuse 43
OS200GB03-42 1SCA128210R1001 Switch fuse 44
OS200GB03K 1SCA128085R1001 Switch fuse 43
OS200GB03N3 1SCA123904R1001 Switch fuse 43
OS200GB03N3-42 1SCA129921R1001 Switch fuse 44
OS200GB03N3K 1SCA128087R1001 Switch fuse 43
OS200GB03N3P 1SCA126216R1001 Switch fuse 43
OS200GB03N3P-42 1SCA129922R1001 Switch fuse 44
OS200GB03P 1SCA125468R1001 Switch fuse 43
OS200GB03P-42 1SCA128211R1001 Switch fuse 44
OS200GB04N1 1SCA125491R1001 Switch fuse 43
OS200GB04N1P 1SCA125493R1001 Switch fuse 43
OS200J02 1SCA107591R1001 Fusible disconnect switch 60
OS200J02P 1SCA107598R1001 Fusible disconnect switch 60
OS200J03 1SCA022733R6130 Fusible disconnect switch 60
OS200J03K 1SCA022763R5800 Fusible disconnect switch 60
OS200J03P 1SCA022709R9760 Fusible disconnect switch 60
OS200J04F 1SCA022758R9340 Fusible disconnect switch 60
OS200J04FP 1SCA022758R9770 Fusible disconnect switch 60
OS200JS30 1SCA022871R3910 Fusible disconnect switch 60
OS200JS30K 1SCA022871R4040 Fusible disconnect switch 60
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 170


Switch fuses
Index

Type Order number Description Page


OS200JS40F 1SCA022871R4120 Fusible disconnect switch 60
OS200JS40FK 1SCA022871R4210 Fusible disconnect switch 60
OS20FB12A1 1SCA108790R1001 Switch fuse 38
OS20FB12A1-2 1SCA108791R1001 Switch fuse 38
OS20FB22A1N1 1SCA108796R1001 Switch fuse 38
OS20FB22A1N1-2 1SCA108797R1001 Switch fuse 38
OS250B02 1SCA022769R9360 Switch fuse 46
OS250B02P 1SCA022769R9440 Switch fuse 46
OS250B03 1SCA022750R6400 Switch fuse 46
OS250B03BB 1SCA102173R1001 Special connected switch fuse 53
OS250B03BBP 1SCA102168R1001 Special connected switch fuse 53
OS250B03K 1SCA022763R6010 Switch fuse 46
OS250B03N3 1SCA022750R7980 Switch fuse 46
OS250B03N3P 1SCA022750R8010 Switch fuse 46
OS250B03P 1SCA022750R6660 Switch fuse 46
OS250B04BBN2 1SCA102175R1001 Special connected switch fuse 53
OS250B04BBN2P 1SCA102164R1001 Special connected switch fuse 53
OS250B04F 1SCA109110R1001 Switch fuse 46
OS250B04FP 1SCA109112R1001 Switch fuse 46
OS250B04N1 1SCA022750R7040 Switch fuse 46
OS250B04N1K 1SCA022763R6100 Switch fuse 46
OS250B04N1P 1SCA022750R7120 Switch fuse 46
OS250B12LR 1SCA022854R5420 Special connected switch fuse 53
OS250B12LRP 1SCA022854R5690 Special connected switch fuse 53
OS250B21LR 1SCA022854R5510 Special connected switch fuse 53
OS250B21LRP 1SCA022854R5850 Special connected switch fuse 53
OS250B22LR 1SCA022854R7120 Special connected switch fuse 53
OS250B22LRP 1SCA022854R7210 Special connected switch fuse 53

06
OS250BS30 1SCA022870R8580 Switch fuse 46
OS250BS30K 1SCA022870R8660 Switch fuse 46
OS250BS40F 1SCA022870R8740 Switch fuse 46
OS250BS40FK 1SCA022870R8820 Switch fuse 46
OS250D02 1SCA022746R7740 Switch fuse 30
OS250D02K 1SCA101367R1001 Switch fuse 30
OS250D02P 1SCA022760R0170 Switch fuse 30
OS250D03 1SCA022720R7080 Switch fuse 30
OS250D03BB 1SCA102197R1001 Special connected switch fuse 36
OS250D03BBP 1SCA012190R1001 Special connected switch fuse 36
OS250D03K 1SCA022763R6360 Switch fuse 30
OS250D03P 1SCA022719R0090 Switch fuse 30
OS250D04BBN2 1SCA102201R1001 Special connected switch fuse 36
OS250D04BBN2P 1SCA102205R1001 Special connected switch fuse 36
OS250D04F 1SCA022727R0360 Switch fuse 30
OS250D04FK 1SCA022783R1310 Switch fuse 30
OS250D04FP 1SCA022726R8620 Switch fuse 30
OS250D04N2 1SCA022725R0500 Switch fuse 30
OS250D04N2K 1SCA022763R6440 Switch fuse 30
OS250D04N2P 1SCA022719R2380 Switch fuse 30
OS250D12LR 1SCA022852R8250 Special connected switch fuse 36
OS250D12LRP 1SCA022852R8410 Special connected switch fuse 36
OS250D21LR 1SCA022852R8330 Special connected switch fuse 36
OS250D21LRP 1SCA022852R8500 Special connected switch fuse 36
OS250D22LR 1SCA022853R0230 Special connected switch fuse 36
OS250D22LRP 1SCA022853R0310 Special connected switch fuse 36
OS250DS30 1SCA022871R2180 Switch fuse 30
OS250DS30K 1SCA022871R2260 Switch fuse 30
OS250DS40F 1SCA022871R2340 Switch fuse 30
OS250DS40FK 1SCA022871R2420 Switch fuse 30
OS250DS40N2 1SCA022871R2510 Switch fuse 30
171 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OS250DS40N2K 1SCA022871R2690 Switch fuse 30
OS25FF1210 1SCA108636R1001 Switch fuse 55
OS25FF1210-2 1SCA108801R1001 Switch fuse 55
OS25FF2210N1 1SCA108638R1001 Switch fuse 55
OS25FF2210N1-2 1SCA108806R1001 Switch fuse 55
OS25FFS3010 1SCA108639R1001 Switch fuse 55
OS25FFS3010-2 1SCA108808R1001 Switch fuse 55
OS30FACC12 1SCA108813R1001 Fusible disconnect switch 57
OS30FACC12P 1SCA108817R1001 Fusible disconnect switch 57
OS30FACC22F 1SCA108819R1001 Fusible disconnect switch 57
OS30FACCS30 1SCA108822R1001 Fusible disconnect switch 57
OS30FAJ12 1SCA108824R1001 Fusible disconnect switch 57
OS30FAJ12P 1SCA108828R1001 Fusible disconnect switch 57
OS30FAJ22F 1SCA108829R1001 Fusible disconnect switch 57
OS30FAJ22FP 1SCA108831R1001 Fusible disconnect switch 57
OS30FAJS30 1SCA108834R1001 Fusible disconnect switch 57
OS315B02 1SCA022817R3370 Switch fuse 47
OS315B02P 1SCA022817R3450 Switch fuse 47
OS315B03 1SCA022753R2070 Switch fuse 47
OS315B03K 1SCA022763R6520 Switch fuse 47
OS315B03N3 1SCA022753R9590 Switch fuse 47
OS315B03N3P 1SCA022753R8940 Switch fuse 47
OS315B03P 1SCA022719R0680 Switch fuse 47
OS315B04F 1SCA022777R5480 Switch fuse 47
OS315B04FP 1SCA022753R6650 Switch fuse 47
OS315B04N1K 1SCA022763R7170 Switch fuse 47
OS315BS30 1SCA022870R9390 Switch fuse 47
OS315BS30K 1SCA022870R9470 Switch fuse 47
OS315BS40F 1SCA022870R9550 Switch fuse 47
OS315BS40FK 1SCA022870R9630 Switch fuse 47
OS32FB12A1 1SCA108840R1001 Switch fuse 38
OS32FB12A1-2 1SCA108841R1001 Switch fuse 38
OS32FB12A2 1SCA108847R1001 Switch fuse 38
OS32FB12A2-2 1SCA108848R1001 Switch fuse 38
OS32FB22A1N1 1SCA108853R1001 Switch fuse 38
OS32FB22A1N1-2 1SCA108855R1001 Switch fuse 38
OS32FB22A2N1 1SCA108863R1001 Switch fuse 38
OS32FB22A2N1-2 1SCA108865R1001 Switch fuse 38
OS32FF1214 1SCA108642R1001 Switch fuse 55
OS32FF1214-2 1SCA108888R1001 Switch fuse 55
OS32FF2214N1-2 1SCA108889R1001 Switch fuse 55
OS32FFD3014-2 1SCA108890R1001 Switch fuse 55
OS32FFS3014 1SCA108646R1001 Switch fuse 55
OS32GB02 1SCA116792R1001 Switch fuse 38
OS32GB02P 1SCA116721R1001 Switch fuse 38
OS32GB03 1SCA115255R1001 Switch fuse 38
OS32GB03K 1SCA116744R1001 Switch fuse 38
OS32GB03P 1SCA115259R1001 Switch fuse 38
OS32GB04N1 1SCA115265R1001 Switch fuse 38
OS32GB04N1K 1SCA116856R1001 Switch fuse 38
OS32GB04N1P 11SCA114610R1001 Switch fuse 38
OS32GBS30 1SCA115955R1001 Switch fuse 38
OS32GBS30K 1SCA115918R1001 Switch fuse 38
OS32GBS40N1 1SCA115956R1001 Switch fuse 38
OS32GBS40N1K 1SCA115923R1001 Switch fuse 38
OS32GD02 1SCA116776R1001 Switch fuse 25
OS32GD02K 1SCA122905R1001 Switch fuse 25
OS32GD02P 1SCA116714R1001 Switch fuse 25
OS32GD03 1SCA115188R1001 Switch fuse 25
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 172


Switch fuses
Index

Type Order number Description Page


OS32GD03K 1SCA116733R1001 Switch fuse 25
OS32GD03P 1SCA115189R1001 Switch fuse 25
OS32GD04F 1SCA115195R1001 Switch fuse 25
OS32GD04FK 1SCA116737R1001 Switch fuse 25
OS32GD04FP 1SCA115196R1001 Switch fuse 25
OS32GD04N2 1SCA115192R1001 Switch fuse 25
OS32GD04N2K 1SCA116734R1001 Switch fuse 25
OS32GD04N2P 1SCA115193R1001 Switch fuse 25
OS32GDS30 1SCA115963R1001 Switch fuse 25
OS32GDS30K 1SCA115929R1001 Switch fuse 25
OS32GDS40F 1SCA116755R1001 Switch fuse 25
OS32GDS40N2 1SCA116046R1001 Switch fuse 25
OS32GDS40N2K 1SCA116402R1001 Switch fuse 25
OS400B02 1SCA022813R7140 Switch fuse 48
OS400B02P 1SCA022813R7220 Switch fuse 48
OS400B03 1SCA022737R4900 Switch fuse 48
OS400B03BB 1SCA102250R1001 Special connected switch fuse 53
OS400B03BBP 1SCA102252R1001 Special connected switch fuse 53
OS400B03K 1SCA022763R6790 Switch fuse 48
OS400B03N3 1SCA022753R9830 Switch fuse 48
OS400B03N3P 1SCA022753R9160 Switch fuse 48
OS400B03P 1SCA022719R0840 Switch fuse 48
OS400B04BBN2 1SCA102239R1001 Special connected switch fuse 53
OS400B04BBN2P 1SCA102248R1001 Special connected switch fuse 53
OS400B04F 1SCA022754R4590 Switch fuse 48
OS400B04FP 1SCA022753R6900 Switch fuse 48
OS400B12LR 1SCA022855R1230 Special connected switch fuse 53
OS400B12LRP 1SCA022855R1400 Special connected switch fuse 53

06
OS400B21LR 1SCA022855R1310 Special connected switch fuse 53
OS400B21LRP 1SCA022855R1580 Special connected switch fuse 53
OS400B22LR 1SCA022855R2630 Special connected switch fuse 53
OS400B22LRP 1SCA022855R2710 Special connected switch fuse 53
OS400BS30 1SCA022871R0130 Switch fuse 48
OS400BS30K 1SCA022871R0210 Switch fuse 48
OS400BS40F 1SCA022871R0300 Switch fuse 48
OS400BS40FK 1SCA022871R0480 Switch fuse 48
OS400D02 1SCA022811R2820 Switch fuse 31
OS400D02K 1SCA101369R1001 Switch fuse 31
OS400D02P 1SCA022811R2740 Switch fuse 31
OS400D03 1SCA022753R1000 Switch fuse 31
OS400D03BB 1SCA102273R1001 Special connected switch fuse 36
OS400D03BBP 1SCA102260R1001 Special connected switch fuse 36
OS400D03K 1SCA022779R5410 Switch fuse 31
OS400D03P 1SCA022719R0250 Switch fuse 31
OS400D04BBN2 1SCA102291R1001 Special connected switch fuse 36
OS400D04BBN2P 1SCA102289R1001 Special connected switch fuse 36
OS400D04F 1SCA022754R3860 Switch fuse 31
OS400D04FK 1SCA022783R1490 Switch fuse 31
OS400D04FP 1SCA022753R7110 Switch fuse 31
OS400D04N2 1SCA022754R2620 Switch fuse 31
OS400D04N2K 1SCA022763R7250 Switch fuse 31
OS400D04N2P 1SCA022719R2460 Switch fuse 31
OS400D12LR 1SCA022853R2010 Special connected switch fuse 36
OS400D12LRP 1SCA022853R2280 Special connected switch fuse 36
OS400D21LR 1SCA022853R2100 Special connected switch fuse 36
OS400D21LRP 1SCA022853R2360 Special connected switch fuse 36
OS400D22LR 1SCA022853R4060 Special connected switch fuse 36
OS400D22LRP 1SCA022853R4140 Special connected switch fuse 36
OS400DS30 1SCA022871R2850 Switch fuse 31
173 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OS400DS30K 1SCA022871R2930 Switch fuse 31
OS400DS40F 1SCA022871R3070 Switch fuse 31
OS400DS40FK 1SCA022871R3150 Switch fuse 31
OS400DS40N2 1SCA022871R3230 Switch fuse 31
OS400J02 1SCA107592R1001 Fusible disconnect switch 61
OS400J02P 1SCA107596R1001 Fusible disconnect switch 61
OS400J03 1SCA022755R0810 Fusible disconnect switch 61
OS400J03K 1SCA117773R1001 Fusible disconnect switch 61
OS400J03P 1SCA022719R1140 Fusible disconnect switch 61
OS400J04F 1SCA022755R3660 Fusible disconnect switch 61
OS400J04FP 1SCA022755R3740 Fusible disconnect switch 61
OS400JS30 1SCA022871R4980 Fusible disconnect switch 61
OS400JS30K 1SCA022871R5010 Fusible disconnect switch 61
OS400JS40F 1SCA022871R5100 Fusible disconnect switch 61
OS400JS40FK 1SCA022871R5280 Fusible disconnect switch 61
OS4010DS40N2K 1SCA022871R3310 Switch fuse 31
OS40FD12000 1SCA108914R1001 Switch fuse 25
OS40FD12000-2 1SCA108921R1001 Switch fuse 25
OS40FD22000N1 1SCA108938R1001 Switch fuse 25
OS40FD22000N1-2 1SCA108940R1001 Switch fuse 25
OS40FDS30000 1SCA108942R1001 Switch fuse 25
OS40FDS30000-2 1SCA108945R1001 Switch fuse 25
OS40FDS40000N1 1SCA108954R1001 Switch fuse 25
OS50GF02 1SCA116798R1001 Switch fuse 55
OS50GF02P 1SCA118345R1001 Switch fuse 55
OS50GF03 1SCA115490R1001 Switch fuse 55
OS50GF03P 1SCA115492R1001 Switch fuse 55
OS50GF04F 1SCA115497R1001 Switch fuse 55
OS50GF04FP 1SCA115498R1001 Switch fuse 55
OS50GFS30 1SCA116050R1001 Switch fuse 55
OS50GFS30K 1SCA116404R1001 Switch fuse 55
OS50GFS40F 1SCA116014R1001 Switch fuse 55
OS50GFS40FK 1SCA116425R1001 Switch fuse 55
OS600J02 1SCA107593R1001 Fusible disconnect switch 62
OS600J02P 1SCA107595R1001 Fusible disconnect switch 62
OS600J03 1SCA022825R8610 Fusible disconnect switch 62
OS600J03K 1SCA117774R1001 Fusible disconnect switch 62
OS600J03P 1SCA022825R8870 Fusible disconnect switch 62
OS600J04F 1SCA022839R3900 Fusible disconnect switch 62
OS600J04FP 1SCA022839R4030 Fusible disconnect switch 62
OS600JS30 1SCA108111R1001 Fusible disconnect switch 62
OS600JS30K 1SCA108112R1001 Fusible disconnect switch 62
OS600JS40F 1SCA108113R1001 Fusible disconnect switch 62
OS600JS40FK 1SCA108114R1001 Fusible disconnect switch 62
OS60GJ02 1SCA121900R1001 Fusible disconnect switch 58
OS60GJ02K 1SCA121927R1001 Fusible disconnect switch 58
OS60GJ02P 1SCA121901R1001 Fusible disconnect switch 58
OS60GJ03 1SCA115866R1001 Fusible disconnect switch 58
OS60GJ03K 1SCA122100R1001 Fusible disconnect switch 58
OS60GJ03P 1SCA115443R1001 Fusible disconnect switch 58
OS60GJ04F 1SCA115445R1001 Fusible disconnect switch 58
OS60GJ04FK 1SCA122098R1001 Fusible disconnect switch 58
OS60GJ04FP 1SCA115446R1001 Fusible disconnect switch 58
OS60GJS30 1SCA116051R1001 Fusible disconnect switch 58
OS60GJS30K 1SCA116426R1001 Fusible disconnect switch 58
OS60GJS40F 1SCA115970R1001 Fusible disconnect switch 58
OS60GJS40FK 1SCA115941R1001 Fusible disconnect switch 58
OS630B02 1SCA113528R1001 Switch fuse 49
OS630B02P 1SCA113529R1001 Switch fuse 49
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 174


Switch fuses
Index

Type Order number Description Page


OS630B03 1SCA022825R5770 Switch fuse 49
OS630B03K 1SCA108708R1001 Switch fuse 49
OS630B03N3 1SCA106295R1001 Switch fuse 49
OS630B03N3P 1SCA100860R1001 Switch fuse 49
OS630B03P 1SCA022825R5850 Switch fuse 49
OS630B04F 1SCA022825R5930 Switch fuse 49
OS630B04FK 1SCA110317R1001 Switch fuse 49
OS630B04FP 1SCA022825R6070 Switch fuse 49
OS630B04N1 1SCA022837R7020 Switch fuse 49
OS630B04N1P 1SCA022837R7110 Switch fuse 49
OS630BS30 1SCA108147R1001 Switch fuse 49
OS630BS30K 1SCA108148R1001 Switch fuse 49
OS630BS40F 1SCA108149R1001 Switch fuse 49
OS630BS40FK 1SCA108150R1001 Switch fuse 49
OS630D02 1SCA106144R1001 Switch fuse 32
OS630D02P 1SCA107745R1001 Switch fuse 32
OS630D03 1SCA022825R2670 Switch fuse 32
OS630D03K 1SCA108704R1001 Switch fuse 32
OS630D03P 1SCA022825R2830 Switch fuse 32
OS630D04F 1SCA022825R4530 Switch fuse 32
OS630D04FK 1SCA110300R1001 Switch fuse 32
OS630D04FP 1SCA022825R4610 Switch fuse 32
OS630D04N2 1SCA022825R4110 Switch fuse 32
OS630D04N2K 1SCA108705R1001 Switch fuse 32
OS630D04N2P 1SCA022825R4290 Switch fuse 32
OS630DS30 1SCA108135R1001 Switch fuse 32
OS630DS30K 1SCA108136R1001 Switch fuse 32
OS630DS40F 1SCA108137R1001 Switch fuse 32

06
OS630DS40FK 1SCA108138R1001 Switch fuse 32
OS630DS40N2 1SCA108139R1001 Switch fuse 32
OS630DS40N2K 1SCA108140R1001 Switch fuse 32
OS63GB02 1SCA116871R1001 Switch fuse 39
OS63GB02P 1SCA116854R1001 Switch fuse 39
OS63GB03 1SCA115234R1001 Switch fuse 39
OS63GB03K 1SCA116745R1001 Switch fuse 39
OS63GB03P 1SCA115235R1001 Switch fuse 39
OS63GB04F 1SCA116304R1001 Switch fuse 39
OS63GB04FP 1SCA116305R1001 Switch fuse 39
OS63GB04N1 1SCA115237R1001 Switch fuse 39
OS63GB04N1K 1SCA116746R1001 Switch fuse 39
OS63GB04N1P 1SCA115238R1001 Switch fuse 39
OS63GBS30 1SCA115957R1001 Switch fuse 39
OS63GBS30K 1SCA115924R1001 Switch fuse 39
OS63GBS40N1 1SCA115978R1001 Switch fuse 39
OS63GBS40N1K 1SCA115979R1001 Switch fuse 39
OS63GD02 1SCA116777R1001 Switch fuse 26
OS63GD02K 1SCA122906R1001 Switch fuse 26
OS63GD02P 1SCA116715R1001 Switch fuse 26
OS63GD03 1SCA115206R1001 Switch fuse 26
OS63GD03K 1SCA116738R1001 Switch fuse 26
OS63GD03P 1SCA115207R1001 Switch fuse 26
OS63GD04F 1SCA115225R1001 Switch fuse 26
OS63GD04FK 1SCA116739R1001 Switch fuse 26
OS63GD04FP 1SCA115228R1001 Switch fuse 26
OS63GD04N2 1SCA115208R1001 Switch fuse 26
OS63GD04N2K 1SCA116876R1001 Switch fuse 26
OS63GD04N2P 1SCA115209R1001 Switch fuse 26
OS63GDS30 1SCA116007R1001 Switch fuse 26
OS63GDS30K 1SCA115931R1001 Switch fuse 26
175 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OS63GDS40F 1SCA116877R1001 Switch fuse 26
OS63GDS40N2 1SCA116047R1001 Switch fuse 26
OS63GDS40N2K 1SCA116403R1001 Switch fuse 26
OS800B02 1SCA022837R6560 Switch fuse 50
OS800B02P 1SCA022837R6480 Switch fuse 50
OS800B03 1SCA022825R7470 Switch fuse 50
OS800B03K 1SCA108713R1001 Switch fuse 50
OS800B03N3 1SCA110102R1001 Switch fuse 50
OS800B03N3P 1SCA100861R1001 Switch fuse 50
OS800B03P 1SCA022825R7550 Switch fuse 50
OS800B04F 1SCA022825R7710 Switch fuse 50
OS800B04FK 1SCA110316R1001 Switch fuse 50
OS800B04FP 1SCA022825R7800 Switch fuse 50
OS800B04N1 1SCA022837R6050 Switch fuse 50
OS800B04N1P 1SCA022837R6130 Switch fuse 50
OS800BS30 1SCA108083R1001 Switch fuse 50
OS800BS30K 1SCA108084R1001 Switch fuse 50
OS800BS40F 1SCA108085R1001 Switch fuse 50
OS800BS40FK 1SCA108102R1001 Switch fuse 50
OS800D02 1SCA022837R2570 Switch fuse 33
OS800D02P 1SCA022837R2650 Switch fuse 33
OS800D03 1SCA022825R4700 Switch fuse 33
OS800D03K 1SCA108725R1001 Switch fuse 33
OS800D03P 1SCA022825R4880 Switch fuse 33
OS800D04F 1SCA022825R8520 Switch fuse 33
OS800D04FK 1SCA110299R1001 Switch fuse 33
OS800D04FP 1SCA022825R5000 Switch fuse 33
OS800D04N2 1SCA022825R5690 Switch fuse 33
OS800D04N2K 1SCA108722R1001 Switch fuse 33
OS800D04N2P 1SCA022825R5180 Switch fuse 33
OS800DS30 1SCA108098R1001 Switch fuse 33
OS800DS30K 1SCA108099R1001 Switch fuse 33
OS800DS40F 1SCA108100R1001 Switch fuse 33
OS800DS40FK 1SCA108101R1001 Switch fuse 33
OS800DS40N2 1SCA108103R1001 Switch fuse 33
OS800DS40N2K 1SCA108104R1001 Switch fuse 33
OS800L02 1SCA116920R1001 Fusible disconnect switch 63
OS800L02P 1SCA116921R1001 Fusible disconnect switch 63
OS800L03 1SCA022825R9760 Fusible disconnect switch 63
OS800L03P 1SCA022825R9920 Fusible disconnect switch 63
OS800L04F 1SCA022839R5350 Fusible disconnect switch 63
OS800L04FP 1SCA022839R5430 Fusible disconnect switch 63
OSB1250DK 1SCA107797R1001 Direct mount handle 72
OSB160/4 1SCA131820R1001 Phase barrier 83
OSB160/6 1SCA131821R1001 Phase barrier 83
OSB250/4 1SCA131822R1001 Phase barrier 83
OSB250/6 1SCA131823R1001 Phase barrier 83
OSD25P3 1SCA022192R9060 Blown fuse indicator 93
OSD25P4 1SCA022196R9520 Blown fuse indicator 93
OSFC1/B10 1SCA149864R1001 Spare part kit 96
OSFC10/B4 1SCA149865R1001 Spare part kit 96
OSFC11 1SCA149866R1001 Spare part kit 96
OSFC12 1SCA149867R1001 Spare part kit 96
OSFC13 1SCA149868R1001 Spare part kit 96
OSFC14 1SCA149869R1001 Spare part kit 96
OSFC15 1SCA149870R1001 Spare part kit 96
OSFC16 1SCA149871R1001 Spare part kit 96
OSFC2/B10 1SCA149572R1001 Spare part kit 96
OSFC3/B10 1SCA149873R1001 Spare part kit 96
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 176


Switch fuses
Index

Type Order number Description Page


OSFC4/B10 1SCA149874R1001 Spare part kit 96
OSFC5/B10 1SCA149875R1001 Spare part kit 96
OSFC6/B10 1SCA149876R1001 Spare part kit 96
OSFC7/B10 1SCA149877R1001 Spare part kit 96
OSFC8/B10 1SCA149878R1001 Spare part kit 96
OSFC9/B4 1SCA149879R1001 Spare part kit 96
OSGD125P3 1SCA115690R1001 Blown fuse indicator 93
OSGD125P4 1SCA115692R1001 Blown fuse indicator 93
OSGD50P3 1SCA116401R1001 Blown fuse indicator 93
OSGD50P4 1SCA115689R1001 Blown fuse indicator 93
OSGZD1 1SCA115688R1001 Mounting accessory 95
OSM100GB3M230C 1SCA116679R1001 Motorized switch fuse 54
OSM100GB4N1M230C 1SCA118779R1001 Motorized switch fuse 54
OSM1250B3M230C 1SCA112552R1001 Motorized switch fuse 54
OSM1250B3N3M230C 1SCA112550R1001 Motorized switch fuse 54
OSM1250B4N1M230C 1SCA118795R1001 Motorized switch fuse 54
OSM1250D3M230C 1SCA112549R1001 Motorized switch fuse 37
OSM1250D3N3M230C 1SCA112547R1001 Motorized switch fuse 37
OSM1250D4N2M230C 1SCA118850R1001 Motorized switch fuse 37
OSM1250DA3M230C 1SCA112546R1001 Motorized switch fuse 37
OSM1250DA3N3M230C 1SCA112544R1001 Motorized switch fuse 37
OSM1250DA4N2M230C 1SCA118851R1001 Motorized switch fuse 37
OSM125GB3M230C 1SCA116677R1001 Motorized switch fuse 54
OSM125GB4N1M230C 1SCA118780R1001 Motorized switch fuse 54
OSM125GD3M230C 1SCA116674R1001 Motorized switch fuse 37
OSM125GD4N2M230C 1SCA118828R1001 Motorized switch fuse 37
OSM160GB3M230C 1SCA116670R1001 Motorized switch fuse 54
OSM160GB4N1M230C 1SCA118781R1001 Motorized switch fuse 54

06
OSM160GD3M230C 1SCA116673R1001 Motorized switch fuse 37
OSM160GD4N2M230C 1SCA118831R1001 Motorized switch fuse 37
OSM200B3M230C 1SCA104272R1001 Motorized switch fuse 54
OSM200B3N3M230C 1SCA104323R1001 Motorized switch fuse 54
OSM200B4N1M230C 1SCA118784R1001 Motorized switch fuse 54
OSM200D3M230C 1SCA104284R1001 Motorized switch fuse 37
OSM200D3N3M230C 1SCA104282R1001 Motorized switch fuse 37
OSM200D4N2M230C 1SCA118836R1001 Motorized switch fuse 37
OSM250B3M230C 1SCA104287R1001 Motorized switch fuse 54
OSM250B3N3M230C 1SCA104290R1001 Motorized switch fuse 54
OSM250B4N1M230C 1SCA118785R1001 Motorized switch fuse 54
OSM250D3M230C 1SCA104295R1001 Motorized switch fuse 37
OSM250D3N3M230C 1SCA104297R1001 Motorized switch fuse 37
OSM250D4N2M230C 1SCA118838R1001 Motorized switch fuse 37
OSM315B3M230C 1SCA104303R1001 Motorized switch fuse 54
OSM315B3N3M230C 1SCA104306R1001 Motorized switch fuse 54
OSM315B4N1M230C 1SCA118788R1001 Motorized switch fuse 54
OSM32GB3M230C 1SCA116662R1001 Motorized switch fuse 54
OSM32GB4N1M230C 1SCA118775R1001 Motorized switch fuse 54
OSM32GD3M230C 1SCA116664R1001 Motorized switch fuse 37
OSM32GD4N2M230C 1SCA118822R1001 Motorized switch fuse 37
OSM400B3M230C 1SCA104310R1001 Motorized switch fuse 54
OSM400B3N3M230C 1SCA104312R1001 Motorized switch fuse 54
OSM400B4N1M230C 1SCA118789R1001 Motorized switch fuse 54
OSM400D3M230C 1SCA104315R1001 Motorized switch fuse 37
OSM400D3N3M230C 1SCA104317R1001 Motorized switch fuse 37
OSM400D4N2M230C 1SCA118842R1001 Motorized switch fuse 37
OSM630B3M230C 1SCA104516R1001 Motorized switch fuse 54
OSM630B3N3M230C 1SCA104535R1001 Motorized switch fuse 54
OSM630B4N1M230C 1SCA118791R1001 Motorized switch fuse 54
OSM630D3M230C 1SCA104518R1001 Motorized switch fuse 37
17 7 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OSM630D3N3M230C 1SCA104533R1001 Motorized switch fuse 37
OSM630D4N2M230C 1SCA118846R1001 Motorized switch fuse 37
OSM63GB3M230C 1SCA116657R1001 Motorized switch fuse 54
OSM63GB4N1M230C 1SCA118776R1001 Motorized switch fuse 54
OSM63GD3M230C 1SCA116660R1001 Motorized switch fuse 37
OSM63GD4N2M230C 1SCA118865R1001 Motorized switch fuse 37
OSM800B3M230C 1SCA104520R1001 Motorized switch fuse 54
OSM800B3N3M230C 1SCA104536R1001 Motorized switch fuse 54
OSM800B4N1M230C 1SCA118792R1001 Motorized switch fuse 54
OSM800D3M230C 1SCA104522R1001 Motorized switch fuse 37
OSM800D3N3M230C 1SCA104534R1001 Motorized switch fuse 37
OSM800D4N2M230C 1SCA118847R1001 Motorized switch fuse 37
OSMC1/B4 1SCA149880R1001 Spare part kit 96
OSMC2/B4 1SCA149881R1001 Spare part kit 96
OSMC3 1SCA149882R1001 Spare part kit 96
OSMC4 1SCA149883R1001 Spare part kit 96
OSMC5 1SCA149884R1001 Spare part kit 96
OSP1250B 1SCA107950R1001 Fourth pole 81
OSP1250D 1SCA107946R1001 Fourth pole 81
OSP1250DA 1SCA112402R1001 Fourth pole 81
OSP1250N 1SCA107943R1001 Neutral link 81
OSP160GB 1SCA114769R1001 Fourth pole 81
OSP160GD 1SCA114768R1001 Fourth pole 81
OSP160GN 1SCA114770R1001 Fourth pole 81
OSP200B 1SCA022735R9180 Fourth pole 81
OSP200D 1SCA022735R8960 Fourth pole 81
OSP200N 1SCA022735R8700 Fourth pole 81
OSP250B 1SCA022770R4030 Fourth pole 81
OSP250D 1SCA022735R9340 Fourth pole 81
OSP250N 1SCA022735R9260 Fourth pole 81
OSP400B 1SCA022770R3140 Fourth pole 81
OSP400D 1SCA022770R3220 Fourth pole 81
OSP400N 1SCA022770R3490 Fourth pole 81
OSP800B 1SCA100434R1001 Fourth pole 81
OSP800D 1SCA100433R1001 Fourth pole 81
OSP800N 1SCA100432R1001 Fourth pole 81
OSS1250G1L/3 1SCA107938R1001 Terminal shroud 84
OSS1250G1L/4 1SCA107940R1001 Terminal shroud 84
OSS1250G1S/3 1SCA107939R1001 Terminal shroud 84
OSS1250G1S/4 1SCA107941R1001 Terminal shroud 84
OSS160GG1L/3 1SCA114764R1001 Terminal shroud 84
OSS160GG1L/4 1SCA114765R1001 Terminal shroud 84
OSS160GG1S/3 1SCA114766R1001 Terminal shroud 84
OSS160GG1S/4 1SCA114767R1001 Terminal shroud 84
OSS160GG3LS 1SCA121570R1001 Terminal shroud 85
OSS160GG4LS 1SCA121571R1001 Terminal shroud 85
OSS200G1L/3 1SCA022731R8910 Terminal shroud 84
OSS200G1L/4 1SCA022731R9040 Terminal shroud 84
OSS200G1S/3 1SCA022732R0130 Terminal shroud 84
OSS200G1S/4 1SCA022732R0050 Terminal shroud 84
OSS250G1L 1SCA022727R5080 Terminal shroud 84
OSS250G1L/3 1SCA022731R9390 Terminal shroud 84
OSS250G1L/4 1SCA022731R9470 Terminal shroud 84
OSS250G1S 1SCA022727R4940 Terminal shroud 84
OSS250G1S/3 1SCA022731R9550 Terminal shroud 84
OSS250G1S/4 1SCA022731R9630 Terminal shroud 84
OSS250G1SH/1 1SCA103500R1001 Terminal shroud 84
OSS400G1L/3 1SCA022776R6650 Terminal shroud 84
OSS400G1L/4 1SCA022776R6730 Terminal shroud 84
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 178


Switch fuses
Index

Type Order number Description Page


OSS400G1S/3 1SCA022776R6900 Terminal shroud 84
OSS400G1S/4 1SCA022776R7030 Terminal shroud 84
OSS400G1SH/1 1SCA103503R1001 Terminal shroud 84
OSS400G3LS 1SCA100396R1001 Terminal shroud 85
OSS400G3SS 1SCA100390R1001 Terminal shroud 85
OSS400G4LSL 1SCA100398R1001 Terminal shroud 85
OSS400G4LSR 1SCA100400R1001 Terminal shroud 85
OSS400G4SSL 1SCA100392R1001 Terminal shroud 85
OSS400G4SSR 1SCA100394R1001 Terminal shroud 85
OSS800G1L/3 1SCA022776R7200 Terminal shroud 84
OSS800G1L/4 1SCA022776R7380 Terminal shroud 84
OSS800G1S/3 1SCA022776R7540 Terminal shroud 84
OSS800G1S/4 1SCA022776R7460 Terminal shroud 84
OSV200BK 1SCA022779R7530 Direct mount handle 72
OSV250DK 1SCA022763R3510 Direct mount handle 72
OSV400BK 1SCA022763R3930 Direct mount handle 72
OSV400DK 1SCA022763R4230 Direct mount handle 72
OSV800DK 1SCA107794R1001 Direct mount handle 72
OSVY1250DK 1SCA108702R1001 Direct mount handle 72
OSVY200BK 1SCA022779R7700 Direct mount handle 72
OSVY250DK 1SCA022778R6500 Direct mount handle 72
OSVY400BK 1SCA022779R5830 Direct mount handle 72
OSVY400DK 1SCA022779R5590 Direct mount handle 72
OSVY800DK 1SCA108703R1001 Direct mount handle 72
OSZ1 1SCA022481R3710 Neutral link 82
OSZ2 1SCA022481R3800 Neutral link 82
OSZ4 1SCA022530R0200 Mounting frame 76
OSZ4 1SCA022530R0200 Mounting accessory 92

06
OSZT1A 1SCA106532R1001 Interlock 94
OSZT1L 1SCA106538R1001 Interlock 94
OSZT2A 1SCA106534R1001 Interlock 94
OSZT2L 1SCA106539R1001 Interlock 94
OSZT3A 1SCA106535R1001 Interlock 94
OSZT3L 1SCA106540R1001 Interlock 94
OSZT4A 1SCA106536R1001 Interlock 94
OSZT4L 1SCA106541R1001 Interlock 94
OSZX3 1SCA101224R1001 Blown fuse indicator 93
OSZX4 1SCA101225R1001 Blown fuse indicator 93
OTS1600G1L 1SCA106134R1001 Terminal shroud 84
OTS1600G1S 1SCA102667R1001 Terminal shroud 84
OTS250G1L 1SCA022715R5340 Terminal shroud 84
OTS250G1S 1SCA022715R5260 Terminal shroud 84
OTS800G1L 1SCA022776R7710 Terminal shroud 84
OTVS1 1SCA111413R1001 Storage clip 83
OTVS2 1SCA111414R1001 Storage clip 83
OTZS2/B10 1SCA126043R1001 Spare part kit 96
OTZT1A 1SCA106522R1001 Interlock 94
OTZT1L 1SCA106527R1001 Interlock 94
OTZW10 1SCA022431R5280 Conversion kit 90
OTZW25 1SCA022778R6920 Conversion kit 90
OTZW26 1SCA022778R7060 Conversion kit 90
OXN1250S 1SCA104163R1001 Neutral link 82
OXN250 1SCA022752R9950 Neutral link 82
OXN250 1SCA022752R9950 Neutral link 82
OXN400 1SCA022770R3060 Neutral link 82
OXN800S 1SCA022831R1880 Neutral link 82
OXP12X250 1SCA022325R6980 Extended shaft 74
OXP12X280 1SCA022137R5140 Extended shaft 74, 75
OXP12X280-45 1SCA022382R0800 Extended shaft 75
179 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Index

Type Order number Description Page


OXP12X325 1SCA022042R5810 Extended shaft 74, 75
OXP12X325-45 1SCA022304R4450 Extended shaft 75
OXP12X395 1SCA022042R5990 Extended shaft 74, 75
OXP12X465 1SCA022042R6020 Extended shaft 74, 75
OXP12X535 1SCA022042R6110 Extended shaft 74, 75
OXP6X130 1SCA022057R0570 Extended shaft 73, 74
OXP6X150 1SCA022295R5600 Extended shaft 73
OXP6X150-45 1SCA022294R4400 Extended shaft 73
OXP6X161 1SCA022067R1760 Extended shaft 73, 74
OXP6X170 1SCA108224R1001 Extended shaft 73
OXP6X170-45 1SCA108227R1001 Extended shaft 73
OXP6X210 1SCA022295R6080 Extended shaft 73, 74
OXP6X210-45 1SCA022294R4230 Extended shaft 73, 74
OXP6X265 1SCA108225R1001 Extended shaft 73
OXP6X265-45 1SCA108228R1001 Extended shaft 73
OXP6X290 1SCA022042R6370 Extended shaft 73, 74
OXP6X290-45 1SCA022304R4290 Extended shaft 73, 74
OXP6X360 1SCA022042R6530 Extended shaft 73, 74
OXP6X360-45 1SCA022341R4640 Extended shaft 73, 74
OXP6X400 1SCA108226R1001 Extended shaft 73
OXP6X400-45 1SCA108229R1001 Extended shaft 73
OXP6X430 1SCA022056R6030 Extended shaft 73, 74
OXP6X63 1SCA111010R1001 Extended shaft 73, 74
OXP6X90 1SCA022064R1180 Extended shaft 73, 74
OZX1 1SCA105708R1001 Spare part kit 96
OZXA-1200 Terminal lug kit 89
OZXA-200 Terminal lug kit 89
OZXA-24 Terminal lug kit 89
OZXA-400 Terminal lug kit 89
OZXA-800 Terminal lug kit 89
OZXB17 1SCA022859R3230 Terminal clamp set 86
OZXB1L 1SCA022169R2030 Terminal clamp set 86
OZXB2 1SCA022119R7610 Terminal clamp set 86
OZXB2K 1SCA022264R0010 Terminal shroud 85
OZXB2L 1SCA022158R7750 Terminal clamp set 86, 87
OZXB3 1SCA022136R8100 Terminal clamp set 86, 87, 88
OZXB3K 1SCA022264R0440 Terminal shroud 85
OZXB4 1SCA022137R4760 Terminal clamp set 86, 87, 88
OZXB4K 1SCA022199R2850 Terminal shroud 85
OZXB5 1SCA022137R2470 Terminal clamp set 86, 87, 88
OZXB5K 1SCA022283R8040 Terminal shroud 85
OZXB6 1SCA022137R4920 Terminal clamp set 87, 88
OZXB7 1SCA022785R0040 Terminal clamp set 87
OZXB7L 1SCA022185R7130 Terminal clamp set 86, 87, 88
OZXB8 1SCA022744R1510 Terminal clamp set 86, 87, 88
OZXB9 1SCA022750R3210 Terminal clamp set 86, 87, 88
OZXP120 1SCA115540R1001 Terminal clamp set 88
OZXP150 1SCA115541R1001 Terminal clamp set 88
OZXP240 1SCA115542R1001 Terminal clamp set 88
OZXP2X240 1SCA115544R1001 Terminal clamp set 88
OZXP300 1SCA115543R1001 Terminal clamp set 88
OZXP95 1SCA115539R1001 Terminal clamp set 88
OZXR185 1SCA115531R1001 Terminal clamp set 88
OZXR240 1SCA115532R1001 Terminal clamp set 88
OZXR2X185 1SCA115534R1001 Terminal clamp set 88
OZXR2X300 1SCA115535R1001 Terminal clamp set 88
OZXR300 1SCA115533R1001 Terminal clamp set 88
OZXR70 1SCA115529R1001 Terminal clamp set 88
OZXR95 1SCA115530R1001 Terminal clamp set 88
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 180


Switch fuses
Index

Type Order number Description Page


OZXT1 1SCA022469R6310 Terminal clamp set 86
PB200 high 1SDA054972R1 Phase barrier 83
PDAL2/110AC50Hz 1SCA106543R1001 Coil 95
PDAL2/110AC60Hz 1SCA107100R1001 Coil 95
PDAL2/110DC 1SCA107105R1001 Coil 95
PDAL2/120AC60Hz 1SCA111353R1001 Coil 95
PDAL2/125DC 1SCA111338R1001 Coil 95
PDAL2/208AC60Hz 1SCA107101R1001 Coil 95
PDAL2/220DC 1SCA112503R1001 Coil 95
PDAL2/230AC50Hz 1SCA107102R1001 Coil 95
PDAL2/240AC60Hz 1SCA111356R1001 Coil 95
PDAL2/24AC60Hz 1SCA111350R1001 Coil 95
PDAL2/24DC 1SCA106542R1001 Coil 95
PDAL2/48DC 1SCA107103R1001 Coil 95
PDAL2/60DC 1SCA107104R1001 Coil 95
PTS800G1S 1SCA022776R8010 Terminal shroud 84

06
181 SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE


Switch fuses
Marketing material

Webpage: Manual operated Webpage: Motorized


switch fuses switch fuses
Homepage for Manual operated switch Homepage for Motorized switch fuses.
fuses.

new.abb.com/low-voltage/products/switches/ new.abb.com/low-voltage/products/switches/
manual-operated-switch-fuses motor-operated-switch-fuses

Catalog: Switch fuses Catalog: Fuse links


Switch fuses -catalog with complete Fuse links -catalog with complete
ordering information. ordering information.

Document ID: 1SCC311013C0201 Document ID: 1SCC317001C0201

Coordination tables Video


Test proven type 2 coordination World class performance in the most
tables where you can easily select the demanding applications.
appropriate ABB components for motor
starting and protection.

applications.it.abb.com/SOC/Page/Selection. youtu.be/I6h8UvbVxAA
aspx
SWITCH FUSES OS AND OSM  WORLD CL ASS PERFORMANCE 182


Switch fuses
Marketing material

Blog Customer case: Pogliano


What’s inside counts. Supplying busbar trunking systems to
the world.

www.abb-conversations.com/2017/05/whats- http://new.abb.com/low-voltage/news/
inside-counts/ pogliano
ABB Oy Note: We reserve the right to make technical
Protection and Connection changes or modify the contents of this do-
P.O. Box 622 cument without prior notice. With regard to
FI-65101 Vaasa, Finland purchase orders, the agreed particulars shall
Phone: +358 10 22 11 prevail. ABB does not accept any responsibi-
Fax: +358 10 22 45708 lity whatsoever for potential errors or possi-
ble lack of information in this document.
www.abb.com
We reserve all rights in this document and in
Find the address of your local sales organization the subject matter and illustrations contai-
on the ABB homepage: ned therein. Any reproduction, disclosure
to third parties or utilization of its contents
www.abb.com/contacts – in whole or in parts – is forbidden without
> Low Voltage Products and Systems prior written consent of ABB.

OS1GB 18-08, 1SCC311013C0201

© Copyright 2018 ABB. All rights reserved.

Vous aimerez peut-être aussi