Vous êtes sur la page 1sur 72

SMD

Structural Floor and Roof Solutions

The White Book


Interactive PDF Floor Deck Design Guide and Tables
The White Book, Product Span Tables

Contents
Page Title

3. . . . .How to use The White Book


4. . . . .Technical Design Table Notes
5. . . . .Step 1, Which Profile and Gauge?

6. . . . .TR50 Floor deck profile


7. . . . .Step 2, TR50 formwork - Which gauge?
8. . . . .TR50 Formwork span tables

10. . . .R51+ Floor deck profile


11. . . .Step 2, R51+ composite slab graph
12. . . .R51+ 1.0 Hour fire rating
18. . . .R51+ 1.5 Hour fire rating
24. . . .R51+ 2.0 Hour fire rating

30. . . .TR60+ Floor deck profile


31. . . .Step 2, TR60+ composite slab graph
32. . . .TR60+ 1.0 Hour fire rating
38. . . .TR60+ 1.5 Hour fire rating
44. . . .TR60+ 2.0 Hour fire rating

50. . . .TR80+ Floor deck profile


51. . . .Step 2, TR80+ composite slab graph
52. . . .TR80+ 1.0 Hour fire rating
58. . . .TR80+ 1.5 Hour fire rating
64. . . .TR80+ 2.0 Hour fire rating

Interactive our
Download PDFInteractive PDF
Visit our
Select the
website
Contents
to download
page or icons
the interactive
contained in
version
this document
of this White
to navigate
Book through the pages

Changes and updates

Version 1 07/09/2017 Document release


Version 2 04/08/2018 R51 replaced with R51+
TR50 added
TR60+ & TR80+ Updated
THE WHITE BOOK
Contents

How to use The White Book


This ‘White Book’ has been developed as a quick reference tool 5.2
Note: This graph is based on A393 mesh. It may be possible to reduce mesh size by referencing
load/span tables during Step 3.

5.2
Note: This graph is based on A393 mesh. It may be possible to reduce mesh size by referencing
load/span tables during Step 3.

5.2
Note: This graph is based on A393 mesh. It may be possible to reduce mesh size by referencing
load/span tables during Step 3.

to be used by architects, engineers and specifiers when looking


5.0 1hr Fire 5.0 1hr Fire 5.0 1hr Fire
1.5hr Fire 1.5hr Fire 1.5hr Fire
4.8 2hr Fire 4.8 2hr Fire 4.8 2hr Fire

4.6 4.6 4.6

for a quick concept design for a composite slab. By following


4.4 4.4 4.4
Construction
Stage
4.2 4.2 4.2
TR80+ 1.2mm
4.0 4.0 4.0 5kN

3.8 3.8 3.8

these 3 simple steps, a suitable deck type/slab/reinforcement


5kN
5kN

Span Length (m)

Span Length (m)


Span Length (m)
r N
3.6 1h 3.6 .5kN 3.6 7.5k
kN 1hr7 10kN Construction 1h
r
10 1hr Stage TR80+ 1.0mm

N
r

7.5k
3.4 3.4 3.4 1h
Construction 10kN
3.2 Stage 3.2 TR60+ 1.2mm 3.2 N

specification can be determined for your project:


R51+ 1.2mm 7.5k TR80+ 0.9mm
3.0 3.0 3.0
7.5kN 7.5
kN
10kN 10kN 7.5kN
2.8 2.8 7.5kN TR60+ 1.0mm
2.8
10kN R51+ 1.0mm
10kN

Min for 1.5hr Fire


2.6 2.6 2.6

Min for 1.5hr Fire

Min for 1.5hr Fire


10kN 10kN

Min for 2hr Fire

Min for 2hr Fire

Min for 2hr Fire


R51+ 0.9mm TR60+ 0.9mm
2.4 2.4 2.4
R51+ 0.8mm
2.2 2.2 2.2

2.0 2.0 2.0


110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 130 140 150 160 170 180 190 200 210 220 230 240 250 140 150 160 170 180 190 200 210 220 230 240 250
Slab Depth (mm) Slab Depth (mm) Slab Depth (mm)

R51+ TR60+ TR80+


Step 1, Which Profile and Gauge?
Refer to Construction Stage graph on page 5. By referring to this graph by checking the profile and slab depth
5.2
from step 1 you can determine the minimum reinforcement
5.0 required – shown by vertical lines within the graph for mesh
4.8 sizes of A142, A193, A252, A393 and 2 x A252, in accordance
4.6
with BS EN 1994-1-1.
4.4

4.2
Should the provisional slab depth from step 1 not be appropriate
TR80+ 1.2mm
for your required loading and fire rating, go back to step 1 and
4.0

3.8
increase the slab, profile and/or deck gauge.
Span Length (m)

3.6
TR80+ 1.0mm

After this step, you should have confirmed provisional profile,


3.4

3.2 TR60+ 1.2mm

3.0
TR80+ 0.9mm
R51+ 1.2mm gauge, slab depth and minimum reinforcement required for the
2.8 TR60+ 1.0mm slab.
R51+ 1.0mm
2.6 TR60+ 0.9mm
R51+ 0.9mm
2.4
R51+ 0.8mm

Step 3, Confirm maximum spans for


2.2

2.0
100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250

your specific design criteria


Slab Depth (mm)

Typically, spans are governed by the maximum 'unpropped'


condition at Construction Stage. This graph considers the Having determined the minimum reinforcement required in step
construction stage design and compares the different SMD 2, you can now determine accurate maximum spans for your
profile/gauges based on decking sheets being double spans design (for both double and single span sheets at this stage, if
(unpropped). required) using the product, fire rating and reinforcement specific
load/span tables. Each design table also enable you to assess
By cross-referencing the slab depth / span, you can then the impact of increasing reinforcement, slab depth or profile
determine which profile and slab depth best suits your proposed gauge for UDL loadings of 3.5kN/m², 5kN/m², 7.5kN/m² and
support configuration. 10kN/m².
Note: Your product choice may also be governed by the stud At the end of step 3 you will now have a confirmed profile,
requirements for your composite beam design. gauge, slab depth and reinforcement for your slab. It should
Once you have reviewed this graph you should have confirmed be noted that the design tables are based on minimum code
profile type (TR50, R51+, TR60+ or TR80+), gauge and requirements and the design assumptions on page 4.
provisional slab depth. In certain situations, increased reinforcement or slab depth will
All tables in this design guide are based on the standard be required over and above that suggested within this guide,
S350 grade profiles. For S450 (or S250 for TR50) guidance i.e. enhanced crack control, acoustic performance etc. This
download Elements® Design Software from www.smdltd. guide is provided as a design tool only and the ultimate design
co.uk. responsibility for the mesh / slab depth in the final condition
remains that of the project structural engineer.

Step 2, Product specific composite Situations not covered in The White Book
slab graphs For situations not covered in The White Book (i.e. isolated single
With the profile confirmed from step 1, refer to the relevant span slabs or slabs subjected to concentrated point or line
page for each profile, referencing the product graphs provides loads), download SMD Elements® design software, available at
the Normal and Fire stage look-up check to ensure the slab www.smdltd.co.uk.
depth proposed from step 1 meets your loading and fire
rating requirement. The graph shows limits for loadings of
5 & 10kN/m² and fire ratings of 1, 1.5 & 2 hours.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 3 of 72
THE WHITE BOOK
Contents

Technical Design Table Notes


The load/span tables in this document are based on the following design assumptions.

Spans Concrete
1. Indicated in meters, from centre to centre of supports. 15. Typical concrete grade C25/30 with 20mm aggregate size.
2. Based on 127mm support widths. 16. Density in accordance with Eurocodes:
3. Double spans assume adjacent spans differ by no more Normal Weight: 2550kg/m³ (Wet) and 2450kg/m³ (Dry)
than 15%.
17. Concrete volumes indicated in sectional properties
4. In all cases, slabs are designed as simply-supported and in are based on the slab poured to a constant thickness
accordance with BS EN 1994-1-1 and UK NAD. (recommended), additional concrete volume of span/250
m³/m² can be added to account for additional concrete as
Note: In some instances the maximum single span may be a result of deck deflection.
greater than the maximum double span. This occurs where
the composite or fire stage govern design, for single spans the
concrete section is often increased due to ponding. Reinforcement
18. Step 2 graphs are based on a single layer of A393 mesh
Loading as for shallow slabs double layers of mesh may be difficult
to install. It may be possible to reduce mesh at Step 3
5. FW in the design tables indicates maximum spans depending on the governing design stage.
where the deck is used as formwork only based on an
increased concrete density of 2650kg/m³ (Wet) to allow for 19. BS EN 1994-1-1 specifies 0.2% of the concrete above the
reinforcement. ribs, where the mesh does not meet this requirement no
span value (-) is shown.
6. Applied loads shown in the look-up tables are un-factored,
however, appropiate load factors have been taken into 20 Top mesh cover of 22mm – Where this is not achievable
account in the derivation of maximum permissible spans. due to the shallow concrete cover above the profile, no
span value (**) is shown. It may be possible to achieve slab
7. Should include consideration for partitions, ceiling, services design in these situations by reducing top mesh cover or
and finishes etc., but not self-weight of the slab as this has providing special mesh laps to enable nesting. For more
been included (where necessary) in the preparation of these guidance refer SMD Technical Guidance Notes (refer SMD
tables. website for TGN Online).
8. Consideration should be given to any loadings that may be
applied to the slab during construction (i.e. from plant or Fire
material storage), as these may be more onerous than the
design loadings for the intended building use. 21. Tables are provided for fire ratings of 1, 1.5 and 2 hours.
22. Where the slab depth does not provide adequate concrete
Construction Stage Loading cover to meet fire insulation requirement, no span value (-)
is shown.
9. Considers wet weight of concrete and reinforcement for the
specified slab depth. 23. The Eurocode NCCI (Mesh Only) method is used,
therefore the composite slab and mesh reinforcement (not
10. Construction Imposed load of 1.5kN/m² or, 0.75kN/m² necessarily the metal deck) must be continuous over one or
generally plus 10% slab weight or 0.75kN/m² (whichever is more internal supports (end bay condition).
greater) over a 3m x 3m 'working area' in accordance with
BS EN 1991-1-1. 24. Load category A/B (Residential/Office) is considered where
the imposed load is less than 7.5kN/m².
11. Concrete volume/weight tables consider concrete only, they
do not include the weight of deck or reinforcement. 25. Load Category E is considered where the imposed load is
7.5kN/m² or greater.
26. All tables assume the fire insulation thickness required is
Deflection
acheived by utilising the structural slab thickness only. It
12. Construction stage is limited to the lesser of Span/180 or may be possible to reduce structural slab thickness where
20mm when deflection is less than slab depth/10. a non-combustible screed is applied and additional bottom
reinforcement provided. Elements® Design Software
13. Limit increased to the lesser of Span/130 or 30mm, when
should be used to check such designs.
concrete ponding is considered for deflections greater than
slab depth/10. In certain design situations governed by fire,
the span may be increased by considering ponding.
All tables in this design guide are based on the standard
14. Tables do not include for any additional concrete as a result
of deflection of the steel frame. S350 grade profiles. For S450 guidance download
Elements® Design Software from www.smdltd.co.uk.

4 of 72
THE WHITE BOOK
Contents

Step 1, Which Profile and Gauge?


Construction Stage Graph
Use this graph to determine which profile and gauge provides an unpropped double span solution for the slab depth and spans
required.

5.2

5.0

4.8

4.6

4.4

4.2
TR80+ 1.2mm
4.0

3.8
Span Length (m)

3.6
TR80+ 1.0mm
3.4

3.2 TR60+ 1.2mm


TR80+ 0.9mm
3.0 R51+ 1.2mm

2.8 TR60+ 1.0mm


R51+ 1.0mm
2.6 TR60+ 0.9mm
R51+ 0.9mm
2.4
TR50 Formwork only
2.2 R51+ 0.8mm

2.0
100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Slab Depth (mm)

(Formwork only)

Page 6 Page 11 Page 31 Page 51


Considerations Considerations Considerations Considerations
• Permanent shuttering only • Flat soffit appearance • Economical option • Reduced concrete volume
• S250, S350 and S550 • Flexible stud positioning • Enhanced speed of fixing • Crushed ends available
Floor Deck Design Guide and Tables
SMD-TEC-528 V2 5 of 72
THE WHITE BOOK
Contents

Floor deck profile


Deck profile

950 Cover width


117 317
50

135
970 Sheet width

Options
• Formwork for non-composite RCC floor and roof slabs
• 120g/m2 galvanised finish as standard, 275g/m2 galvanised finish and colour-coat finish also available
• Optimised cover width for speed of installation
• Flexible side-lap detail for control of cover width
• Trough stiffener location designed to optimise stud position and avoid additional on-site checks

Concrete volume and weight


Overall Slab Depth (mm)
Concrete 100 110 120 130 140 150 175 200 225 250 275 300

Volume (m3/m2) 0.076 0.086 0.096 0.106 0.116 0.126 0.151 0.176 0.201 0.226 0.251 0.276
Weight (kN/m2) 1.98 2.24 2.50 2.76 3.02 3.28 3.93 4.58 5.23 5.88 6.53 7.18

Profile properties
Nominal Design Thickness Available Grades Depth of Profile Weight of Profile Weight of Profile Height of Neutral Area of Steel Moment of Inertia
Thickness mm (bare steel) mm N/mm2 mm kg/m2 kN/m2 axis mm mm2/m cm4/m

0.7 0.66 350* 50 6.82 0.07 - - -


0.8 0.76 350* 50 7.85 0.08 - - -
0.9 0.86 350* 50 8.88 0.09 - - -
1.0 0.96 350* 50 9.92 0.10 - - -
1.2 1.16 350* 50 11.98 0.12 - - -

* This design guide is based on S350 grade steel, S250 grade is also available, download SMD Elements® Design software for calculations.

6 of 72
THE WHITE BOOK
Back to Step 1

Step 2, TR50 formwork - Which gauge?


Span and slab depth guidance graph
With formwork only profile determined at step 1, review the graph below to consider the gauge required for your span and slab
depth specification.

4.2

4.0

3.8

3.6
See Page 5 for composite floor deck profiles
3.4

3.2

3.0

2.8
Span Length (m)

2.6

2.4

2.2
TR50 1.2mm
2.0

1.8
TR50 1.0mm
1.6
TR50 0.9mm
1.4
TR50 0.8mm
1.2
TR50 0.7mm
1.0
100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Slab Depth (mm)

Formwork only
span tables
Pg.8

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 7 of 72
FORMWORK
BOOK
Contents
Maximum Permissible Span (m)

0.7mm Gauge 0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge
THE WHITE

Deck Slab
Mesh FW FW FW FW FW
Span Depth

FW Single 110 2.141 2.366 2.573 2.757 3.085

FW Single 120 2.073 2.326 2.496 2.68 2.996

FW Single 130 2.01 2.281 2.426 2.608 2.914

FW Single 140 1.953 2.215 2.362 2.538 2.843

FW Single 150 1.903 2.157 2.304 2.476 2.777

FW Single 160 1.854 2.104 2.25 2.418 2.719

FW Single 170 1.812 2.053 2.199 2.366 2.664

FW Single 180 1.75 2.006 2.125 2.312 2.612

FW Single 190 1.68 1.961 2.108 2.265 2.565

FW Single 200 1.608 1.922 2.069 2.222 2.523

FW Single 210 1.546 1.883 2.03 2.18 2.48

FW Single 220 1.492 1.85 1.992 2.141 2.438

FW Single 230 1.438 1.815 1.957 2.104 2.399

FW Single 240 1.387 1.765 1.922 2.069 2.358

FW Single 250 1.343 1.703 1.891 2.037 2.319

FW Double 110 1.934 2.234 2.531 2.812 3.306

FW Double 120 1.839 2.125 2.414 2.688 3.164

FW Double 130 1.757 2.037 2.312 2.569 3.031

FW Double 140 1.68 1.949 2.219 2.469 2.914

FW Double 150 1.612 1.875 2.133 2.375 2.812

FW Double 160 1.55 1.804 2.053 2.292 2.711

FW Double 170 1.496 1.742 1.984 2.215 2.625

FW Double 180 1.445 1.68 1.918 2.141 2.546

FW Double 190 1.395 1.625 1.858 2.077 2.469

FW Double 200 1.354 1.577 1.804 2.014 2.399

FW Double 210 1.312 1.531 1.75 1.961 2.335

FW Double 220 1.273 1.488 1.703 1.907 2.273

FW Double 230 1.238 1.449 1.657 1.858 2.219

FW Double 240 1.207 1.41 1.616 1.812 2.164

FW Double 250 1.172 1.375 1.577 1.765 2.112

8 of 72
El
Elements®
Span Check

El
Design
Tool
Span Check
Elements® Design App
Software

Run maximum span checks on all SMD


profiles, at the tip of your fingers!
Our free-to-download app is a calculation tool enabling users run
simple span checks on our range of floor deck profiles.

Free to download
The easy-to-use app, helps users to understand the options
available for each product and what can be achieved with different
types of specification.

To download, please visit


www.smdltd.co.uk

Connect with us
THE WHITE BOOK
Contents

Floor deck profile


Deck profile
Updated from the original R51 product in 2018, this profile is available in S350 and S450 grades to provide
the designer greater flexibility. R51+ is a traditional re-entrant profile commonly used on inner city multi-
R51
storey projects where the structural zone and storey height is reduced, due to the relatively thin slab depth
required to achieve a typical 1 hour fire rating.
600 Cover Width
40 150
52

137

Options
• 102mm minimum slab depth, whilst still achieving 1 hour fire rating
• Profile optimised to maximise structural efficiency of steel
• 150mm trough spacings provide flexibility for stud placement, particularly important for building
footprints with irregular geometry (raking beams)
• Soffit ‘Wedge Nut’ fixings available with load capacity of up to 2kN
• Product options include HIGH DURABILITY HD steel coating & TAB-Deck™ fibre concrete solution

Concrete volume and weight


Slab Depth Volume of Concrete Weight of Concrete (Normal Weight) Weight of Concrete (Lightweight)
mm m³/m² Wet kN/m² Dry kN/m² Wet kN/m² Dry kN/m²

120 0.111 2.78 2.67 2.23 2.12


130 0.121 3.03 2.91 2.43 2.31
140 0.131 3.28 3.15 2.63 2.51
150 0.141 3.53 3.39 2.83 2.70
175 0.166 4.15 3.99 3.34 3.17
200 0.191 4.78 4.59 3.84 3.65
225 0.216 5.40 5.19 4.34 4.13
250 0.241 6.03 5.79 4.84 4.61
Deflection – This table is based on concrete poured to a constant thickness and does not take account for deflection of the decking or supporting beams (as a guide, to account for the deflection of the
decking, a concrete volume of span/250 should be added to the figures indicated). Concrete Weight – These tables indicate concrete weight only and do not include the weight of decking or reinforcement.
Concrete weights are based on the concrete densities specified in Technical Design Table Notes, see page 4.

Profile properties
Nominal Design Grade Depth of Profile Weight of Profile Weight of Profile Height of Area of Steel Moment of Inertia
Thickness mm Thickness mm N/mm² mm kg/m² kN/m² Neutral Axis mm mm²/m cm4/m
0.8 0.76 350 52 12.02 0.118 15.8 1464 56.90
0.9 0.86 350* 52 13.54 0.133 16.2 1657 61.27
1.0 0.96 350* 52 15.01 0.147 16.5 1845 68.73
1.2 1.16 350* 52 17.98 0.176 17.0 2223 85.60
* This design guide is based on S350 grade steel, S450 grade is also available, download SMD Elements® Design software for calculations.

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

10 of 72
THE WHITE BOOK
Back to Step 1

Step 2, R51+ composite slab graph


Span and slab depth guidance graph
With proposed profile and gauge determined at step 1 on page 5, review the graph below to consider whether Load and Fire rating
govern the design. Construction stage governs (shown dashed) except where solid lines representing the different Load/Fire limits
are shown.

Note: This graph is based on A393 mesh. It may be possible to reduce mesh size by referencing
load/span tables during Step 3.

5.2

5.0 1hr Fire


1.5hr Fire
4.8 2hr Fire

4.6

4.4

4.2

4.0

3.8
Span Length (m)

r
3.6 1h
kN *
10
kN

3.4
7.5

Construction
3.2 Stage
R51+ 1.2mm
3.0
7.5kN
N
2.8 10k
N
10k R51+ 1.0mm
2.6
Min for 1.5hr Fire

Min for 2hr Fire

R51+ 0.9mm
2.4
R51+ 0.8mm
2.2

2.0
110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Slab Depth (mm)

1.0 Hour 1.5 Hour 2.0 Hour


Fire Rating Fire Rating Fire Rating
A142 A193 A252 A393 A142 A193 A252 A393 A142 A193 A252 A393
Pg.12 Pg.13 Pg.14 Pg.15 Pg.18 Pg.19 Pg.20 Pg.21 Pg.24 Pg.25 Pg.26 Pg.27

* Refer to Note 13 on Page 4

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 11 of 72
1.0 Hr
A142 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 2.616 2.616 2.616 2.616 2.850 2.850 2.850 2.850 3.046 3.046 3.046 2.953 3.319 3.319 3.319 3.108

A142 Single 120 2.553 2.553 2.553 2.553 2.777 2.777 2.777 2.777 2.969 2.969 2.969 2.969 3.238 3.238 3.238 3.238

A142 Single 130 - - - - - - - - - - - - - - - -

A142 Single 140 - - - - - - - - - - - - - - - -

A142 Single 150 - - - - - - - - - - - - - - - -

A142 Single 160 - - - - - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - - - - - -

A142 Double 110 3.062 3.062 2.875 2.596 3.281 3.281 2.969 2.680 3.507 3.507 3.054 2.757 3.938 3.938 3.219 2.899

A142 Double 120 2.976 2.976 2.969 2.688 3.216 3.216 3.069 2.773 3.422 3.422 3.157 2.854 3.835 3.835 3.327 3.007

A142 Double 130 - - - - - - - - - - - - - - - -

A142 Double 140 - - - - - - - - - - - - - - - -

A142 Double 150 - - - - - - - - - - - - - - - -

A142 Double 160 - - - - - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

12 of 72
1.0 Hr
A193 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 2.616 2.616 2.616 2.616 2.850 2.850 2.850 2.850 3.042 3.042 3.042 3.042 3.315 3.315 3.315 3.234

A193 Single 120 2.552 2.552 2.552 2.552 2.773 2.773 2.773 2.773 2.965 2.965 2.965 2.965 3.234 3.234 3.234 3.234

A193 Single 130 2.534 2.534 2.534 2.534 2.707 2.707 2.707 2.707 2.891 2.891 2.891 2.891 3.160 3.160 3.160 3.160

A193 Single 140 2.469 2.469 2.469 2.469 2.645 2.645 2.645 2.645 2.827 2.827 2.827 2.827 3.093 3.093 3.093 3.093

A193 Single 150 - - - - - - - - - - - - - - - -

A193 Single 160 - - - - - - - - - - - - - - - -

A193 Single 170 - - - - - - - - - - - - - - - -

A193 Single 180 - - - - - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - - - - - -

A193 Double 110 3.062 3.062 2.945 2.660 3.281 3.281 3.031 2.738 3.507 3.507 3.116 2.812 3.930 3.930 3.273 2.953

A193 Double 120 2.969 2.969 2.969 2.804 3.214 3.214 3.188 2.883 3.414 3.414 3.414 2.961 3.835 3.835 3.633 3.108

A193 Double 130 2.891 2.891 2.891 2.891 3.180 3.180 3.180 3.015 3.335 3.335 3.335 3.093 3.742 3.742 3.742 3.250

A193 Double 140 2.819 2.819 2.819 2.819 3.100 3.100 3.100 3.089 3.300 3.300 3.300 3.172 3.649 3.649 3.649 3.335

A193 Double 150 - - - - - - - - - - - - - - - -

A193 Double 160 - - - - - - - - - - - - - - - -

A193 Double 170 - - - - - - - - - - - - - - - -

A193 Double 180 - - - - - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 13 of 72
1.0 Hr
A252 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A252 Single 120 2.550 2.550 2.550 2.550 2.773 2.773 2.773 2.773 2.961 2.961 2.961 2.961 3.230 3.230 3.230 3.230

A252 Single 130 2.531 2.531 2.531 2.531 2.703 2.703 2.703 2.703 2.891 2.891 2.891 2.891 3.157 3.157 3.157 3.157

A252 Single 140 2.469 2.469 2.469 2.469 2.641 2.641 2.641 2.641 2.827 2.827 2.827 2.827 3.093 3.093 3.093 3.093

A252 Single 150 2.410 2.410 2.410 2.410 2.585 2.585 2.585 2.585 2.765 2.765 2.765 2.765 3.031 3.031 3.031 3.031

A252 Single 160 2.358 2.358 2.358 2.358 2.531 2.531 2.531 2.531 2.703 2.703 2.703 2.703 2.970 2.970 2.970 2.970

A252 Single 170 2.304 2.304 2.304 2.304 2.476 2.476 2.476 2.476 2.649 2.649 2.649 2.649 2.922 2.922 2.922 2.922

A252 Single 180 - - - - - - - - - - - - - - - -

A252 Single 190 - - - - - - - - - - - - - - - -

A252 Single 200 - - - - - - - - - - - - - - - -

A252 Single 210 - - - - - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - - - - - -

A252 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A252 Double 120 2.969 2.969 2.969 2.866 3.212 3.212 3.212 2.945 3.414 3.414 3.414 3.015 3.827 3.827 3.750 3.157

A252 Double 130 2.891 2.891 2.891 2.891 3.172 3.172 3.172 3.085 3.327 3.327 3.327 3.164 3.734 3.734 3.734 3.312

A252 Double 140 2.819 2.819 2.819 2.819 3.093 3.093 3.093 3.093 3.298 3.298 3.298 3.298 3.649 3.649 3.649 3.649

A252 Double 150 2.750 2.750 2.750 2.750 3.023 3.023 3.023 3.023 3.242 3.242 3.242 3.242 3.569 3.569 3.569 3.569

A252 Double 160 2.688 2.688 2.688 2.688 2.953 2.953 2.953 2.953 3.172 3.172 3.172 3.172 3.492 3.492 3.492 3.492

A252 Double 170 2.626 2.626 2.626 2.626 2.887 2.887 2.887 2.887 3.100 3.100 3.100 3.100 3.472 3.472 3.472 3.472

A252 Double 180 - - - - - - - - - - - - - - - -

A252 Double 190 - - - - - - - - - - - - - - - -

A252 Double 200 - - - - - - - - - - - - - - - -

A252 Double 210 - - - - - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

14 of 72
1.0 Hr
A393 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A393 Single 120 2.545 2.545 2.545 2.545 2.765 2.765 2.765 2.765 2.953 2.953 2.953 2.953 3.226 3.226 3.226 3.226

A393 Single 130 2.527 2.527 2.527 2.527 2.703 2.703 2.703 2.703 2.883 2.883 2.883 2.883 3.153 3.153 3.153 3.153

A393 Single 140 2.465 2.465 2.465 2.465 2.637 2.637 2.637 2.637 2.819 2.819 2.819 2.819 3.085 3.085 3.085 3.085

A393 Single 150 2.407 2.407 2.407 2.407 2.577 2.577 2.577 2.577 2.757 2.757 2.757 2.757 3.027 3.027 3.027 3.027

A393 Single 160 2.350 2.350 2.350 2.350 2.523 2.523 2.523 2.523 2.703 2.703 2.703 2.703 2.969 2.969 2.969 2.969

A393 Single 170 2.304 2.304 2.304 2.304 2.476 2.476 2.476 2.476 2.649 2.649 2.649 2.649 2.918 2.918 2.918 2.918

A393 Single 180 2.253 2.253 2.253 2.253 2.426 2.426 2.426 2.426 2.596 2.596 2.596 2.596 2.866 2.866 2.866 2.866

A393 Single 190 2.211 2.211 2.211 2.211 2.383 2.383 2.383 2.383 2.546 2.546 2.546 2.546 2.823 2.823 2.823 2.823

A393 Single 200 2.168 2.168 2.168 2.168 2.339 2.339 2.339 2.339 2.503 2.503 2.503 2.503 2.781 2.781 2.781 2.781

A393 Single 210 2.126 2.126 2.126 2.126 2.300 2.300 2.300 2.300 2.461 2.461 2.461 2.461 2.738 2.738 2.738 2.738

A393 Single 220 2.093 2.093 2.093 2.093 2.261 2.261 2.261 2.261 2.422 2.422 2.422 2.422 2.703 2.703 2.703 2.703

A393 Single 230 2.053 2.053 2.053 2.053 2.226 2.226 2.226 2.226 2.383 2.383 2.383 2.383 2.664 2.664 2.664 2.664

A393 Single 240 2.022 2.022 2.022 2.022 2.188 2.188 2.188 2.188 2.343 2.343 2.343 2.343 2.633 2.633 2.633 2.633

A393 Single 250 - - - - - - - - - - - - - - - -

A393 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A393 Double 120 2.969 2.969 2.969 2.969 3.206 3.206 3.206 3.062 3.407 3.407 3.407 3.133 3.827 3.827 3.827 3.500

A393 Double 130 2.887 2.887 2.887 2.887 3.172 3.172 3.172 3.172 3.327 3.327 3.327 3.327 3.734 3.734 3.734 3.719

A393 Double 140 2.812 2.812 2.812 2.812 3.093 3.093 3.093 3.093 3.293 3.293 3.293 3.293 3.649 3.649 3.649 3.649

A393 Double 150 2.746 2.746 2.746 2.746 3.015 3.015 3.015 3.015 3.242 3.242 3.242 3.242 3.562 3.562 3.562 3.562

A393 Double 160 2.684 2.684 2.684 2.684 2.945 2.945 2.945 2.945 3.164 3.164 3.164 3.164 3.492 3.492 3.492 3.492

A393 Double 170 2.625 2.625 2.625 2.625 2.883 2.883 2.883 2.883 3.100 3.100 3.100 3.100 3.468 3.468 3.468 3.468

A393 Double 180 2.569 2.569 2.569 2.569 2.827 2.827 2.827 2.827 3.031 3.031 3.031 3.031 3.430 3.430 3.430 3.430

A393 Double 190 2.519 2.519 2.519 2.519 2.765 2.765 2.765 2.765 2.969 2.969 2.969 2.969 3.358 3.358 3.358 3.358

A393 Double 200 2.469 2.469 2.469 2.469 2.711 2.711 2.711 2.711 2.914 2.914 2.914 2.914 3.296 3.296 3.296 3.296

A393 Double 210 2.426 2.426 2.426 2.426 2.664 2.664 2.664 2.664 2.862 2.862 2.862 2.862 3.234 3.234 3.234 3.234

A393 Double 220 2.383 2.383 2.383 2.383 2.616 2.616 2.616 2.616 2.812 2.812 2.812 2.812 3.180 3.180 3.180 3.180

A393 Double 230 2.343 2.343 2.343 2.343 2.569 2.569 2.569 2.569 2.765 2.765 2.765 2.765 3.125 3.125 3.125 3.125

A393 Double 240 2.304 2.304 2.304 2.304 2.531 2.531 2.531 2.531 2.719 2.719 2.719 2.719 3.069 3.069 3.069 3.069

A393 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 15 of 72
1.0 Hr
2xA252 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 130 2.523 2.523 2.523 2.523 2.695 2.695 2.695 2.695 2.883 2.883 2.883 2.883 3.149 3.149 3.149 3.149

2xA252 Single 140 2.461 2.461 2.461 2.461 2.633 2.633 2.633 2.633 2.815 2.815 2.815 2.815 3.081 3.081 3.081 3.081

2xA252 Single 150 2.403 2.403 2.403 2.403 2.577 2.577 2.577 2.577 2.757 2.757 2.757 2.757 3.023 3.023 3.023 3.023

2xA252 Single 160 2.350 2.350 2.350 2.350 2.523 2.523 2.523 2.523 2.695 2.695 2.695 2.695 2.965 2.965 2.965 2.965

2xA252 Single 170 2.296 2.296 2.296 2.296 2.469 2.469 2.469 2.469 2.641 2.641 2.641 2.641 2.914 2.914 2.914 2.914

2xA252 Single 180 2.250 2.250 2.250 2.250 2.420 2.420 2.420 2.420 2.593 2.593 2.593 2.593 2.866 2.866 2.866 2.866

2xA252 Single 190 2.207 2.207 2.207 2.207 2.379 2.379 2.379 2.379 2.546 2.546 2.546 2.546 2.819 2.819 2.819 2.819

2xA252 Single 200 2.164 2.164 2.164 2.164 2.335 2.335 2.335 2.335 2.500 2.500 2.500 2.500 2.777 2.777 2.777 2.777

2xA252 Single 210 2.125 2.125 2.125 2.125 2.296 2.296 2.296 2.296 2.457 2.457 2.457 2.457 2.738 2.738 2.738 2.738

2xA252 Single 220 2.089 2.089 2.089 2.089 2.257 2.257 2.257 2.257 2.418 2.418 2.418 2.418 2.699 2.699 2.699 2.699

2xA252 Single 230 2.053 2.053 2.053 2.053 2.222 2.222 2.222 2.222 2.379 2.379 2.379 2.379 2.664 2.664 2.664 2.664

2xA252 Single 240 2.022 2.022 2.022 2.022 2.188 2.188 2.188 2.188 2.343 2.343 2.343 2.343 2.629 2.629 2.629 2.629

2xA252 Single 250 1.988 1.988 1.988 1.988 2.153 2.153 2.153 2.153 2.308 2.308 2.308 2.308 2.593 2.593 2.593 2.593

2xA252 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 130 2.883 2.883 2.883 2.883 3.164 3.164 3.164 3.164 3.319 3.319 3.319 3.319 3.726 3.726 3.726 3.726

2xA252 Double 140 2.812 2.812 2.812 2.812 3.085 3.085 3.085 3.085 3.289 3.289 3.289 3.289 3.641 3.641 3.641 3.641

2xA252 Double 150 2.742 2.742 2.742 2.742 3.015 3.015 3.015 3.015 3.234 3.234 3.234 3.234 3.562 3.562 3.562 3.562

2xA252 Double 160 2.680 2.680 2.680 2.680 2.945 2.945 2.945 2.945 3.164 3.164 3.164 3.164 3.484 3.484 3.484 3.484

2xA252 Double 170 2.625 2.625 2.625 2.625 2.883 2.883 2.883 2.883 3.093 3.093 3.093 3.093 3.464 3.464 3.464 3.464

2xA252 Double 180 2.569 2.569 2.569 2.569 2.819 2.819 2.819 2.819 3.031 3.031 3.031 3.031 3.422 3.422 3.422 3.422

2xA252 Double 190 2.515 2.515 2.515 2.515 2.765 2.765 2.765 2.765 2.969 2.969 2.969 2.969 3.358 3.358 3.358 3.358

2xA252 Double 200 2.469 2.469 2.469 2.469 2.711 2.711 2.711 2.711 2.914 2.914 2.914 2.914 3.296 3.296 3.296 3.296

2xA252 Double 210 2.422 2.422 2.422 2.422 2.664 2.664 2.664 2.664 2.858 2.858 2.858 2.858 3.234 3.234 3.234 3.234

2xA252 Double 220 2.383 2.383 2.383 2.383 2.616 2.616 2.616 2.616 2.808 2.808 2.808 2.808 3.172 3.172 3.172 3.172

2xA252 Double 230 2.339 2.339 2.339 2.339 2.569 2.569 2.569 2.569 2.757 2.757 2.757 2.757 3.120 3.120 3.120 3.120

2xA252 Double 240 2.300 2.300 2.300 2.300 2.527 2.527 2.527 2.527 2.715 2.715 2.715 2.715 3.069 3.069 3.069 3.069

2xA252 Double 250 2.261 2.261 2.261 2.261 2.488 2.488 2.488 2.488 2.672 2.672 2.672 2.672 3.019 3.019 3.019 3.019

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

16 of 72
1.0 Hr
2xA393BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 130 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 140 2.453 2.453 2.453 2.453 2.625 2.625 2.625 2.625 2.804 2.804 2.804 2.804 3.069 3.069 3.069 3.069

2xA393 Single 150 2.395 2.395 2.395 2.395 2.569 2.569 2.569 2.569 2.746 2.746 2.746 2.746 3.011 3.011 3.011 3.011

2xA393 Single 160 2.343 2.343 2.343 2.343 2.515 2.515 2.515 2.515 2.688 2.688 2.688 2.688 2.957 2.957 2.957 2.957

2xA393 Single 170 2.292 2.292 2.292 2.292 2.465 2.465 2.465 2.465 2.633 2.633 2.633 2.633 2.903 2.903 2.903 2.903

2xA393 Single 180 2.242 2.242 2.242 2.242 2.418 2.418 2.418 2.418 2.585 2.585 2.585 2.585 2.858 2.858 2.858 2.858

2xA393 Single 190 2.199 2.199 2.199 2.199 2.374 2.374 2.374 2.374 2.538 2.538 2.538 2.538 2.812 2.812 2.812 2.812

2xA393 Single 200 2.157 2.157 2.157 2.157 2.331 2.331 2.331 2.331 2.490 2.490 2.490 2.490 2.769 2.769 2.769 2.769

2xA393 Single 210 2.120 2.120 2.120 2.120 2.288 2.288 2.288 2.288 2.453 2.453 2.453 2.453 2.730 2.730 2.730 2.730

2xA393 Single 220 2.085 2.085 2.085 2.085 2.250 2.250 2.250 2.250 2.414 2.414 2.414 2.414 2.691 2.691 2.691 2.691

2xA393 Single 230 2.049 2.049 2.049 2.049 2.215 2.215 2.215 2.215 2.375 2.375 2.375 2.375 2.657 2.657 2.657 2.657

2xA393 Single 240 2.014 2.014 2.014 2.014 2.180 2.180 2.180 2.180 2.335 2.335 2.335 2.335 2.625 2.625 2.625 2.625

2xA393 Single 250 1.984 1.984 1.984 1.984 2.149 2.149 2.149 2.149 2.304 2.304 2.304 2.304 2.585 2.585 2.585 2.585

2xA393 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 130 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 140 2.804 2.804 2.804 2.804 3.077 3.077 3.077 3.077 3.279 3.279 3.279 3.279 3.633 3.633 3.633 3.633

2xA393 Double 150 2.734 2.734 2.734 2.734 3.007 3.007 3.007 3.007 3.226 3.226 3.226 3.226 3.554 3.554 3.554 3.554

2xA393 Double 160 2.672 2.672 2.672 2.672 2.938 2.938 2.938 2.938 3.157 3.157 3.157 3.157 3.476 3.476 3.476 3.476

2xA393 Double 170 2.616 2.616 2.616 2.616 2.875 2.875 2.875 2.875 3.085 3.085 3.085 3.085 3.456 3.456 3.456 3.456

2xA393 Double 180 2.562 2.562 2.562 2.562 2.812 2.812 2.812 2.812 3.023 3.023 3.023 3.023 3.414 3.414 3.414 3.414

2xA393 Double 190 2.511 2.511 2.511 2.511 2.757 2.757 2.757 2.757 2.961 2.961 2.961 2.961 3.350 3.350 3.350 3.350

2xA393 Double 200 2.461 2.461 2.461 2.461 2.703 2.703 2.703 2.703 2.907 2.907 2.907 2.907 3.288 3.288 3.288 3.288

2xA393 Double 210 2.418 2.418 2.418 2.418 2.657 2.657 2.657 2.657 2.850 2.850 2.850 2.850 3.226 3.226 3.226 3.226

2xA393 Double 220 2.375 2.375 2.375 2.375 2.608 2.608 2.608 2.608 2.804 2.804 2.804 2.804 3.168 3.168 3.168 3.168

2xA393 Double 230 2.335 2.335 2.335 2.335 2.562 2.562 2.562 2.562 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

2xA393 Double 240 2.294 2.294 2.294 2.294 2.523 2.523 2.523 2.523 2.711 2.711 2.711 2.711 3.062 3.062 3.062 3.062

2xA393 Double 250 2.255 2.255 2.255 2.255 2.484 2.484 2.484 2.484 2.664 2.664 2.664 2.664 3.015 3.015 3.015 3.015

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 17 of 72
1.5 Hr
A142 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 2.616 2.616 2.327 2.100 2.850 2.850 2.395 2.164 3.046 3.046 2.461 2.226 3.319 3.319 2.585 2.335

A142 Single 120 2.553 2.553 2.422 2.191 2.777 2.777 2.492 2.257 2.969 2.969 2.562 2.319 3.238 3.238 2.695 2.438

A142 Single 130 - - - - - - - - - - - - - - - -

A142 Single 140 - - - - - - - - - - - - - - - -

A142 Single 150 - - - - - - - - - - - - - - - -

A142 Single 160 - - - - - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - - - - - -

A142 Double 110 3.062 3.062 2.327 2.100 3.281 3.281 2.395 2.164 3.507 3.484 2.461 2.226 3.938 3.649 2.585 2.335

A142 Double 120 2.976 2.976 2.422 2.191 3.216 3.216 2.492 2.257 3.422 3.422 2.562 2.319 3.835 3.796 2.695 2.438

A142 Double 130 - - - - - - - - - - - - - - - -

A142 Double 140 - - - - - - - - - - - - - - - -

A142 Double 150 - - - - - - - - - - - - - - - -

A142 Double 160 - - - - - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

18 of 72
1.5 Hr
A193 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 2.616 2.616 2.422 2.188 2.850 2.850 2.484 2.246 3.042 3.042 2.546 2.300 3.315 3.315 2.664 2.407

A193 Single 120 2.552 2.552 2.511 2.273 2.773 2.773 2.773 2.335 2.965 2.965 2.883 2.391 3.234 3.234 2.992 2.507

A193 Single 130 2.534 2.534 2.534 2.362 2.707 2.707 2.707 2.430 2.891 2.891 2.891 2.488 3.160 3.160 3.157 2.608

A193 Single 140 2.469 2.469 2.469 2.457 2.645 2.645 2.645 2.645 2.827 2.827 2.827 2.781 3.093 3.093 3.093 2.711

A193 Single 150 - - - - - - - - - - - - - - - -

A193 Single 160 - - - - - - - - - - - - - - - -

A193 Single 170 - - - - - - - - - - - - - - - -

A193 Single 180 - - - - - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - - - - - -

A193 Double 110 3.062 3.062 2.422 2.188 3.281 3.281 2.484 2.246 3.507 3.507 2.546 2.300 3.930 3.858 2.664 2.407

A193 Double 120 2.969 2.969 2.511 2.273 3.214 3.214 2.577 2.335 3.414 3.414 2.645 2.391 3.835 3.835 2.765 2.507

A193 Double 130 2.891 2.891 2.608 2.362 3.180 3.180 2.676 2.430 3.335 3.335 2.742 2.488 3.742 3.742 2.875 2.608

A193 Double 140 2.819 2.819 2.703 2.457 3.100 3.100 2.781 2.523 3.300 3.300 2.850 2.589 3.649 3.649 2.984 2.711

A193 Double 150 - - - - - - - - - - - - - - - -

A193 Double 160 - - - - - - - - - - - - - - - -

A193 Double 170 - - - - - - - - - - - - - - - -

A193 Double 180 - - - - - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 19 of 72
1.5 Hr
A252 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A252 Single 120 2.550 2.550 2.550 2.358 2.773 2.773 2.773 2.414 2.961 2.961 2.961 2.469 3.230 3.230 3.203 2.577

A252 Single 130 2.531 2.531 2.531 2.441 2.703 2.703 2.703 2.500 2.891 2.891 2.891 2.796 3.157 3.157 3.157 2.672

A252 Single 140 2.469 2.469 2.469 2.469 2.641 2.641 2.641 2.641 2.827 2.827 2.827 2.827 3.093 3.093 3.093 3.046

A252 Single 150 2.410 2.410 2.410 2.410 2.585 2.585 2.585 2.585 2.765 2.765 2.765 2.765 3.031 3.031 3.031 3.031

A252 Single 160 2.358 2.358 2.358 2.358 2.531 2.531 2.531 2.531 2.703 2.703 2.703 2.703 2.970 2.970 2.970 2.970

A252 Single 170 2.304 2.304 2.304 2.304 2.476 2.476 2.476 2.476 2.649 2.649 2.649 2.649 2.922 2.922 2.922 2.922

A252 Single 180 - - - - - - - - - - - - - - - -

A252 Single 190 - - - - - - - - - - - - - - - -

A252 Single 200 - - - - - - - - - - - - - - - -

A252 Single 210 - - - - - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - - - - - -

A252 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A252 Double 120 2.969 2.969 2.604 2.358 3.212 3.212 2.668 2.414 3.414 3.414 2.730 2.469 3.827 3.827 2.843 2.577

A252 Double 130 2.891 2.891 2.695 2.441 3.172 3.172 2.757 2.500 3.327 3.327 2.827 2.562 3.734 3.734 2.945 2.672

A252 Double 140 2.819 2.819 2.788 2.531 3.093 3.093 2.858 2.596 3.298 3.298 2.922 2.657 3.649 3.649 3.054 2.773

A252 Double 150 2.750 2.750 2.750 2.633 3.023 3.023 2.965 2.695 3.242 3.242 3.031 2.757 3.569 3.569 3.164 2.883

A252 Double 160 2.688 2.688 2.688 2.688 2.953 2.953 2.953 2.804 3.172 3.172 3.149 2.870 3.492 3.492 3.281 2.992

A252 Double 170 2.626 2.626 2.626 2.626 2.887 2.887 2.887 2.887 3.100 3.100 3.100 2.976 3.472 3.472 3.399 3.100

A252 Double 180 - - - - - - - - - - - - - - - -

A252 Double 190 - - - - - - - - - - - - - - - -

A252 Double 200 - - - - - - - - - - - - - - - -

A252 Double 210 - - - - - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

20 of 72
1.5 Hr
A393 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A393 Single 120 2.545 2.545 2.545 2.527 2.765 2.765 2.765 2.765 2.953 2.953 2.953 2.953 3.226 3.226 3.226 3.108

A393 Single 130 2.527 2.527 2.527 2.527 2.703 2.703 2.703 2.703 2.883 2.883 2.883 2.883 3.153 3.153 3.153 3.153

A393 Single 140 2.465 2.465 2.465 2.465 2.637 2.637 2.637 2.637 2.819 2.819 2.819 2.819 3.085 3.085 3.085 3.085

A393 Single 150 2.407 2.407 2.407 2.407 2.577 2.577 2.577 2.577 2.757 2.757 2.757 2.757 3.027 3.027 3.027 3.027

A393 Single 160 2.350 2.350 2.350 2.350 2.523 2.523 2.523 2.523 2.703 2.703 2.703 2.703 2.969 2.969 2.969 2.969

A393 Single 170 2.304 2.304 2.304 2.304 2.476 2.476 2.476 2.476 2.649 2.649 2.649 2.649 2.918 2.918 2.918 2.918

A393 Single 180 2.253 2.253 2.253 2.253 2.426 2.426 2.426 2.426 2.596 2.596 2.596 2.596 2.866 2.866 2.866 2.866

A393 Single 190 2.211 2.211 2.211 2.211 2.383 2.383 2.383 2.383 2.546 2.546 2.546 2.546 2.823 2.823 2.823 2.823

A393 Single 200 2.168 2.168 2.168 2.168 2.339 2.339 2.339 2.339 2.503 2.503 2.503 2.503 2.781 2.781 2.781 2.781

A393 Single 210 2.126 2.126 2.126 2.126 2.300 2.300 2.300 2.300 2.461 2.461 2.461 2.461 2.738 2.738 2.738 2.738

A393 Single 220 2.093 2.093 2.093 2.093 2.261 2.261 2.261 2.261 2.422 2.422 2.422 2.422 2.703 2.703 2.703 2.703

A393 Single 230 2.053 2.053 2.053 2.053 2.226 2.226 2.226 2.226 2.383 2.383 2.383 2.383 2.664 2.664 2.664 2.664

A393 Single 240 2.022 2.022 2.022 2.022 2.188 2.188 2.188 2.188 2.343 2.343 2.343 2.343 2.633 2.633 2.633 2.633

A393 Single 250 - - - - - - - - - - - - - - - -

A393 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

A393 Double 120 2.969 2.969 2.792 2.527 3.206 3.206 2.850 2.577 3.407 3.407 2.899 2.625 3.827 3.827 3.007 2.719

A393 Double 130 2.887 2.887 2.875 2.604 3.172 3.172 2.930 2.657 3.327 3.327 2.992 2.711 3.734 3.734 3.100 2.812

A393 Double 140 2.812 2.812 2.812 2.688 3.093 3.093 3.023 2.742 3.293 3.293 3.085 2.800 3.649 3.649 3.195 2.907

A393 Double 150 2.746 2.746 2.746 2.746 3.015 3.015 3.015 2.839 3.242 3.242 3.180 2.895 3.562 3.562 3.562 3.007

A393 Double 160 2.684 2.684 2.684 2.684 2.945 2.945 2.945 2.938 3.164 3.164 3.164 3.000 3.492 3.492 3.492 3.108

A393 Double 170 2.625 2.625 2.625 2.625 2.883 2.883 2.883 2.883 3.100 3.100 3.100 3.093 3.468 3.468 3.468 3.211

A393 Double 180 2.569 2.569 2.569 2.569 2.827 2.827 2.827 2.827 3.031 3.031 3.031 3.031 3.430 3.430 3.430 3.304

A393 Double 190 2.519 2.519 2.519 2.519 2.765 2.765 2.765 2.765 2.969 2.969 2.969 2.969 3.358 3.358 3.358 3.358

A393 Double 200 2.469 2.469 2.469 2.469 2.711 2.711 2.711 2.711 2.914 2.914 2.914 2.914 3.296 3.296 3.296 3.296

A393 Double 210 2.426 2.426 2.426 2.426 2.664 2.664 2.664 2.664 2.862 2.862 2.862 2.862 3.234 3.234 3.234 3.234

A393 Double 220 2.383 2.383 2.383 2.383 2.616 2.616 2.616 2.616 2.812 2.812 2.812 2.812 3.180 3.180 3.180 3.180

A393 Double 230 2.343 2.343 2.343 2.343 2.569 2.569 2.569 2.569 2.765 2.765 2.765 2.765 3.125 3.125 3.125 3.125

A393 Double 240 2.304 2.304 2.304 2.304 2.531 2.531 2.531 2.531 2.719 2.719 2.719 2.719 3.069 3.069 3.069 3.069

A393 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 21 of 72
1.5 Hr
2xA252 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 130 2.523 2.523 2.523 2.523 2.695 2.695 2.695 2.695 2.883 2.883 2.883 2.883 3.149 3.149 3.149 3.149

2xA252 Single 140 2.461 2.461 2.461 2.461 2.633 2.633 2.633 2.633 2.815 2.815 2.815 2.815 3.081 3.081 3.081 3.081

2xA252 Single 150 2.403 2.403 2.403 2.403 2.577 2.577 2.577 2.577 2.757 2.757 2.757 2.757 3.023 3.023 3.023 3.023

2xA252 Single 160 2.350 2.350 2.350 2.350 2.523 2.523 2.523 2.523 2.695 2.695 2.695 2.695 2.965 2.965 2.965 2.965

2xA252 Single 170 2.296 2.296 2.296 2.296 2.469 2.469 2.469 2.469 2.641 2.641 2.641 2.641 2.914 2.914 2.914 2.914

2xA252 Single 180 2.250 2.250 2.250 2.250 2.376 2.376 2.376 2.376 2.593 2.593 2.593 2.593 2.866 2.866 2.866 2.866

2xA252 Single 190 2.207 2.207 2.207 2.207 2.379 2.379 2.379 2.379 2.546 2.546 2.546 2.546 2.819 2.819 2.819 2.819

2xA252 Single 200 2.164 2.164 2.164 2.164 2.335 2.335 2.335 2.335 2.500 2.500 2.500 2.500 2.777 2.777 2.777 2.777

2xA252 Single 210 2.125 2.125 2.125 2.125 2.296 2.296 2.296 2.296 2.457 2.457 2.457 2.457 2.738 2.738 2.738 2.738

2xA252 Single 220 2.089 2.089 2.089 2.089 2.257 2.257 2.257 2.257 2.418 2.418 2.418 2.418 2.699 2.699 2.699 2.699

2xA252 Single 230 2.053 2.053 2.053 2.053 2.222 2.222 2.222 2.222 2.379 2.379 2.379 2.379 2.664 2.664 2.664 2.664

2xA252 Single 240 2.022 2.022 2.022 2.022 2.188 2.188 2.188 2.188 2.343 2.343 2.343 2.343 2.629 2.629 2.629 2.629

2xA252 Single 250 1.988 1.988 1.988 1.988 2.153 2.153 2.153 2.153 2.308 2.308 2.308 2.308 2.593 2.593 2.593 2.593

2xA252 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 130 2.883 2.883 2.883 2.875 3.164 3.164 3.164 2.922 3.319 3.319 3.319 2.969 3.726 3.726 3.726 3.054

2xA252 Double 140 2.812 2.812 2.812 2.812 3.085 3.085 3.085 2.984 3.289 3.289 3.289 3.038 3.641 3.641 3.641 3.125

2xA252 Double 150 2.742 2.742 2.742 2.742 3.015 3.015 3.015 3.015 3.234 3.234 3.234 3.116 3.562 3.562 3.562 3.531

2xA252 Double 160 2.680 2.680 2.680 2.680 2.945 2.945 2.945 2.945 3.164 3.164 3.164 3.164 3.484 3.484 3.484 3.304

2xA252 Double 170 2.625 2.625 2.625 2.625 2.883 2.883 2.883 2.883 3.093 3.093 3.093 3.093 3.464 3.464 3.464 3.383

2xA252 Double 180 2.569 2.569 2.569 2.569 2.819 2.819 2.819 2.819 3.031 3.031 3.031 3.031 3.422 3.422 3.422 3.422

2xA252 Double 190 2.515 2.515 2.515 2.515 2.765 2.765 2.765 2.765 2.969 2.969 2.969 2.969 3.358 3.358 3.358 3.358

2xA252 Double 200 2.469 2.469 2.469 2.469 2.711 2.711 2.711 2.711 2.914 2.914 2.914 2.914 3.296 3.296 3.296 3.296

2xA252 Double 210 2.422 2.422 2.422 2.422 2.664 2.664 2.664 2.664 2.858 2.858 2.858 2.858 3.234 3.234 3.234 3.234

2xA252 Double 220 2.383 2.383 2.383 2.383 2.616 2.616 2.616 2.616 2.808 2.808 2.808 2.808 3.172 3.172 3.172 3.172

2xA252 Double 230 2.339 2.339 2.339 2.339 2.569 2.569 2.569 2.569 2.757 2.757 2.757 2.757 3.120 3.120 3.120 3.120

2xA252 Double 240 2.300 2.300 2.300 2.300 2.527 2.527 2.527 2.527 2.715 2.715 2.715 2.715 3.069 3.069 3.069 3.069

2xA252 Double 250 2.261 2.261 2.261 2.261 2.488 2.488 2.488 2.488 2.672 2.672 2.672 2.672 3.019 3.019 3.019 3.019

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

22 of 72
1.5 Hr
2xA393BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 130 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 140 2.453 2.453 2.453 2.453 2.625 2.625 2.625 2.625 2.804 2.804 2.804 2.804 3.069 3.069 3.069 3.069

2xA393 Single 150 2.395 2.395 2.395 2.395 2.569 2.569 2.569 2.569 2.746 2.746 2.746 2.746 3.011 3.011 3.011 3.011

2xA393 Single 160 2.343 2.343 2.343 2.343 2.515 2.515 2.515 2.515 2.688 2.688 2.688 2.688 2.957 2.957 2.957 2.957

2xA393 Single 170 2.292 2.292 2.292 2.292 2.465 2.465 2.465 2.465 2.633 2.633 2.633 2.633 2.903 2.903 2.903 2.903

2xA393 Single 180 2.242 2.242 2.242 2.242 2.418 2.418 2.418 2.418 2.585 2.585 2.585 2.585 2.858 2.858 2.858 2.858

2xA393 Single 190 2.199 2.199 2.199 2.199 2.374 2.374 2.374 2.374 2.538 2.538 2.538 2.538 2.812 2.812 2.812 2.812

2xA393 Single 200 2.157 2.157 2.157 2.157 2.331 2.331 2.331 2.331 2.490 2.490 2.490 2.490 2.769 2.769 2.769 2.769

2xA393 Single 210 2.120 2.120 2.120 2.120 2.288 2.288 2.288 2.288 2.453 2.453 2.453 2.453 2.730 2.730 2.730 2.730

2xA393 Single 220 2.085 2.085 2.085 2.085 2.250 2.250 2.250 2.250 2.414 2.414 2.414 2.414 2.691 2.691 2.691 2.691

2xA393 Single 230 2.049 2.049 2.049 2.049 2.215 2.215 2.215 2.215 2.375 2.375 2.375 2.375 2.657 2.657 2.657 2.657

2xA393 Single 240 2.014 2.014 2.014 2.014 2.180 2.180 2.180 2.180 2.335 2.335 2.335 2.335 2.625 2.625 2.625 2.625

2xA393 Single 250 1.984 1.984 1.984 1.984 2.149 2.149 2.149 2.149 2.304 2.304 2.304 2.304 2.585 2.585 2.585 2.585

2xA393 Double 110 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 120 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 130 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 140 2.804 2.804 2.804 2.804 3.077 3.077 3.077 3.077 3.279 3.279 3.279 3.279 3.633 3.633 3.633 3.633

2xA393 Double 150 2.734 2.734 2.734 2.734 3.007 3.007 3.007 3.007 3.226 3.226 3.226 3.226 3.554 3.554 3.554 3.554

2xA393 Double 160 2.672 2.672 2.672 2.672 2.938 2.938 2.938 2.938 3.157 3.157 3.157 3.157 3.476 3.476 3.476 3.476

2xA393 Double 170 2.616 2.616 2.616 2.616 2.875 2.875 2.875 2.875 3.085 3.085 3.085 3.085 3.456 3.456 3.456 3.456

2xA393 Double 180 2.562 2.562 2.562 2.562 2.812 2.812 2.812 2.812 3.023 3.023 3.023 3.023 3.414 3.414 3.414 3.414

2xA393 Double 190 2.511 2.511 2.511 2.511 2.757 2.757 2.757 2.757 2.961 2.961 2.961 2.961 3.350 3.350 3.350 3.350

2xA393 Double 200 2.461 2.461 2.461 2.461 2.703 2.703 2.703 2.703 2.907 2.907 2.907 2.907 3.288 3.288 3.288 3.288

2xA393 Double 210 2.418 2.418 2.418 2.418 2.657 2.657 2.657 2.657 2.850 2.850 2.850 2.850 3.226 3.226 3.226 3.226

2xA393 Double 220 2.375 2.375 2.375 2.375 2.608 2.608 2.608 2.608 2.804 2.804 2.804 2.804 3.168 3.168 3.168 3.168

2xA393 Double 230 2.335 2.335 2.335 2.335 2.562 2.562 2.562 2.562 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

2xA393 Double 240 2.294 2.294 2.294 2.294 2.523 2.523 2.523 2.523 2.711 2.711 2.711 2.711 3.062 3.062 3.062 3.062

2xA393 Double 250 2.255 2.255 2.255 2.255 2.484 2.484 2.484 2.484 2.664 2.664 2.664 2.664 3.015 3.015 3.015 3.015

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 23 of 72
2.0 Hr
A142 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 - - - - - - - - - - - - - - - -

A142 Single 120 - - - - - - - - - - - - - - - -

A142 Single 130 - - - - - - - - - - - - - - - -

A142 Single 140 - - - - - - - - - - - - - - - -

A142 Single 150 - - - - - - - - - - - - - - - -

A142 Single 160 - - - - - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - - - - - -

A142 Double 110 - - - - - - - - - - - - - - - -

A142 Double 120 - - - - - - - - - - - - - - - -

A142 Double 130 - - - - - - - - - - - - - - - -

A142 Double 140 - - - - - - - - - - - - - - - -

A142 Double 150 - - - - - - - - - - - - - - - -

A142 Double 160 - - - - - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

24 of 72
2.0 Hr
A193 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 - - - - - - - - - - - - - - - -

A193 Single 120 - - - - - - - - - - - - - - - -

A193 Single 130 2.534 2.534 2.370 2.149 2.707 2.707 2.430 2.203 2.891 2.891 2.488 2.257 3.160 3.160 2.596 2.358

A193 Single 140 2.469 2.469 2.445 2.226 2.645 2.645 2.645 2.281 2.827 2.827 2.788 2.335 3.093 3.093 2.680 2.438

A193 Single 150 - - - - - - - - - - - - - - - -

A193 Single 160 - - - - - - - - - - - - - - - -

A193 Single 170 - - - - - - - - - - - - - - - -

A193 Single 180 - - - - - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - - - - - -

A193 Double 110 - - - - - - - - - - - - - - - -

A193 Double 120 - - - - - - - - - - - - - - - -

A193 Double 130 2.891 2.891 2.370 2.149 3.180 3.180 2.430 2.203 3.335 3.335 2.488 2.257 3.742 3.657 2.596 2.358

A193 Double 140 2.819 2.819 2.445 2.226 3.100 3.100 2.507 2.281 3.300 3.300 2.569 2.335 3.649 3.649 2.680 2.438

A193 Double 150 - - - - - - - - - - - - - - - -

A193 Double 160 - - - - - - - - - - - - - - - -

A193 Double 170 - - - - - - - - - - - - - - - -

A193 Double 180 - - - - - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 25 of 72
2.0 Hr
A252 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 - - - - - - - - - - - - - - - -

A252 Single 120 - - - - - - - - - - - - - - - -

A252 Single 130 2.531 2.531 2.469 2.242 2.703 2.703 2.703 2.292 2.891 2.891 2.875 2.339 3.157 3.157 2.680 2.434

A252 Single 140 2.469 2.469 2.469 2.308 2.641 2.641 2.641 2.362 2.827 2.827 2.827 2.414 3.093 3.093 3.077 2.511

A252 Single 150 2.410 2.410 2.410 2.383 2.585 2.585 2.585 2.438 2.765 2.765 2.765 2.492 3.031 3.031 3.031 2.593

A252 Single 160 2.358 2.358 2.358 2.358 2.531 2.531 2.531 2.531 2.703 2.703 2.703 2.703 2.970 2.970 2.970 2.970

A252 Single 170 2.304 2.304 2.304 2.304 2.476 2.476 2.476 2.476 2.649 2.649 2.649 2.649 2.922 2.922 2.922 2.922

A252 Single 180 - - - - - - - - - - - - - - - -

A252 Single 190 - - - - - - - - - - - - - - - -

A252 Single 200 - - - - - - - - - - - - - - - -

A252 Single 210 - - - - - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - - - - - -

A252 Double 110 - - - - - - - - - - - - - - - -

A252 Double 120 - - - - - - - - - - - - - - - -

A252 Double 130 2.891 2.891 2.469 2.242 3.172 3.172 2.523 2.292 3.327 3.327 2.577 2.339 3.734 3.734 2.680 2.434

A252 Double 140 2.819 2.819 2.538 2.308 3.093 3.093 2.600 2.362 3.298 3.298 2.657 2.414 3.649 3.649 2.765 2.511

A252 Double 150 2.750 2.750 2.620 2.383 3.023 3.023 2.680 2.438 3.242 3.242 2.738 2.492 3.569 3.569 2.850 2.593

A252 Double 160 2.688 2.688 2.688 2.469 2.953 2.953 2.765 2.523 3.172 3.172 2.827 2.577 3.492 3.492 2.938 2.680

A252 Double 170 2.626 2.626 2.626 2.554 2.887 2.887 2.858 2.608 3.100 3.100 2.922 2.668 3.472 3.472 3.038 2.773

A252 Double 180 - - - - - - - - - - - - - - - -

A252 Double 190 - - - - - - - - - - - - - - - -

A252 Double 200 - - - - - - - - - - - - - - - -

A252 Double 210 - - - - - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

26 of 72
2.0 Hr
A393 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 - - - - - - - - - - - - - - - -

A393 Single 120 - - - - - - - - - - - - - - - -

A393 Single 130 2.527 2.527 2.527 2.422 2.703 2.703 2.703 2.465 2.883 2.883 2.883 2.875 3.153 3.153 3.153 2.593

A393 Single 140 2.465 2.465 2.465 2.465 2.637 2.637 2.637 2.637 2.819 2.819 2.819 2.819 3.085 3.085 3.085 3.046

A393 Single 150 2.407 2.407 2.407 2.407 2.577 2.577 2.577 2.577 2.757 2.757 2.757 2.757 3.027 3.027 3.027 3.027

A393 Single 160 2.350 2.350 2.350 2.350 2.523 2.523 2.523 2.523 2.703 2.703 2.703 2.703 2.969 2.969 2.969 2.969

A393 Single 170 2.304 2.304 2.304 2.304 2.476 2.476 2.476 2.476 2.649 2.649 2.649 2.649 2.918 2.918 2.918 2.918

A393 Single 180 2.253 2.253 2.253 2.253 2.426 2.426 2.426 2.426 2.596 2.596 2.596 2.596 2.866 2.866 2.866 2.866

A393 Single 190 2.211 2.211 2.211 2.211 2.383 2.383 2.383 2.383 2.546 2.546 2.546 2.546 2.823 2.823 2.823 2.823

A393 Single 200 2.168 2.168 2.168 2.168 2.339 2.339 2.339 2.339 2.503 2.503 2.503 2.503 2.781 2.781 2.781 2.781

A393 Single 210 2.126 2.126 2.126 2.126 2.300 2.300 2.300 2.300 2.461 2.461 2.461 2.461 2.738 2.738 2.738 2.738

A393 Single 220 2.093 2.093 2.093 2.093 2.261 2.261 2.261 2.261 2.422 2.422 2.422 2.422 2.703 2.703 2.703 2.703

A393 Single 230 2.053 2.053 2.053 2.053 2.226 2.226 2.226 2.226 2.383 2.383 2.383 2.383 2.664 2.664 2.664 2.664

A393 Single 240 2.022 2.022 2.022 2.022 2.188 2.188 2.188 2.188 2.343 2.343 2.343 2.343 2.633 2.633 2.633 2.633

A393 Single 250 - - - - - - - - - - - - - - - -

A393 Double 110 - - - - - - - - - - - - - - - -

A393 Double 120 - - - - - - - - - - - - - - - -

A393 Double 130 2.887 2.887 2.672 2.422 3.172 3.172 2.719 2.465 3.327 3.327 2.765 2.507 3.734 3.734 2.858 2.593

A393 Double 140 2.812 2.812 2.734 2.484 3.093 3.093 2.788 2.531 3.293 3.293 2.835 2.577 3.649 3.649 2.930 2.664

A393 Double 150 2.746 2.746 2.746 2.554 3.015 3.015 2.858 2.600 3.242 3.242 2.907 2.649 3.562 3.562 3.007 2.738

A393 Double 160 2.684 2.684 2.684 2.625 2.945 2.945 2.938 2.680 3.164 3.164 2.992 2.726 3.492 3.492 3.093 2.819

A393 Double 170 2.625 2.625 2.625 2.625 2.883 2.883 2.883 2.757 3.100 3.100 3.077 2.808 3.468 3.468 3.180 2.907

A393 Double 180 2.569 2.569 2.569 2.569 2.827 2.827 2.827 2.827 3.031 3.031 3.031 2.891 3.430 3.430 3.273 2.992

A393 Double 190 2.519 2.519 2.519 2.519 2.765 2.765 2.765 2.765 2.969 2.969 2.969 2.969 3.358 3.358 3.350 3.073

A393 Double 200 2.469 2.469 2.469 2.469 2.711 2.711 2.711 2.711 2.914 2.914 2.914 2.914 3.296 3.296 3.296 3.153

A393 Double 210 2.426 2.426 2.426 2.426 2.664 2.664 2.664 2.664 2.862 2.862 2.862 2.862 3.234 3.234 3.234 3.234

A393 Double 220 2.383 2.383 2.383 2.383 2.616 2.616 2.616 2.616 2.812 2.812 2.812 2.812 3.180 3.180 3.180 3.180

A393 Double 230 2.343 2.343 2.343 2.343 2.569 2.569 2.569 2.569 2.765 2.765 2.765 2.765 3.125 3.125 3.125 3.125

A393 Double 240 2.304 2.304 2.304 2.304 2.531 2.531 2.531 2.531 2.719 2.719 2.719 2.719 3.069 3.069 3.069 3.069

A393 Double 250 - - - - - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 27 of 72
2.0 Hr
2xA252 BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 - - - - - - - - - - - - - - - -

2xA252 Single 120 - - - - - - - - - - - - - - - -

2xA252 Single 130 2.523 2.523 2.523 2.523 2.695 2.695 2.695 2.695 2.883 2.883 2.883 2.883 3.149 3.149 3.149 3.149

2xA252 Single 140 2.461 2.461 2.461 2.461 2.633 2.633 2.633 2.633 2.815 2.815 2.815 2.815 3.081 3.081 3.081 3.081

2xA252 Single 150 2.403 2.403 2.403 2.403 2.577 2.577 2.577 2.577 2.757 2.757 2.757 2.757 3.023 3.023 3.023 3.023

2xA252 Single 160 2.350 2.350 2.350 2.350 2.523 2.523 2.523 2.523 2.695 2.695 2.695 2.695 2.965 2.965 2.965 2.965

2xA252 Single 170 2.296 2.296 2.296 2.296 2.469 2.469 2.469 2.469 2.641 2.641 2.641 2.641 2.914 2.914 2.914 2.914

2xA252 Single 180 2.250 2.250 2.250 2.250 2.376 2.376 2.376 2.376 2.593 2.593 2.593 2.593 2.866 2.866 2.866 2.866

2xA252 Single 190 2.207 2.207 2.207 2.207 2.379 2.379 2.379 2.379 2.546 2.546 2.546 2.546 2.819 2.819 2.819 2.819

2xA252 Single 200 2.164 2.164 2.164 2.164 2.335 2.335 2.335 2.335 2.500 2.500 2.500 2.500 2.777 2.777 2.777 2.777

2xA252 Single 210 2.125 2.125 2.125 2.125 2.296 2.296 2.296 2.296 2.457 2.457 2.457 2.457 2.738 2.738 2.738 2.738

2xA252 Single 220 2.089 2.089 2.089 2.089 2.257 2.257 2.257 2.257 2.418 2.418 2.418 2.418 2.699 2.699 2.699 2.699

2xA252 Single 230 2.053 2.053 2.053 2.053 2.222 2.222 2.222 2.222 2.379 2.379 2.379 2.379 2.664 2.664 2.664 2.664

2xA252 Single 240 2.022 2.022 2.022 2.022 2.188 2.188 2.188 2.188 2.343 2.343 2.343 2.343 2.629 2.629 2.629 2.629

2xA252 Single 250 1.988 1.988 1.988 1.988 2.153 2.153 2.153 2.153 2.308 2.308 2.308 2.308 2.593 2.593 2.593 2.593

2xA252 Double 110 - - - - - - - - - - - - - - - -

2xA252 Double 120 - - - - - - - - - - - - - - - -

2xA252 Double 130 2.883 2.883 2.883 2.719 3.164 3.164 3.038 2.757 3.319 3.319 3.077 2.792 3.726 3.726 3.157 2.862

2xA252 Double 140 2.812 2.812 2.812 2.765 3.085 3.085 3.085 2.808 3.289 3.289 3.133 2.843 3.641 3.641 3.593 2.922

2xA252 Double 150 2.742 2.742 2.742 2.742 3.015 3.015 3.015 2.862 3.234 3.234 3.188 2.903 3.562 3.562 3.562 2.984

2xA252 Double 160 2.680 2.680 2.680 2.680 2.945 2.945 2.945 2.922 3.164 3.164 3.164 2.965 3.484 3.484 3.343 3.046

2xA252 Double 170 2.625 2.625 2.625 2.625 2.883 2.883 2.883 2.883 3.093 3.093 3.093 3.031 3.464 3.464 3.414 3.116

2xA252 Double 180 2.569 2.569 2.569 2.569 2.819 2.819 2.819 2.819 3.031 3.031 3.031 3.031 3.422 3.422 3.422 3.188

2xA252 Double 190 2.515 2.515 2.515 2.515 2.765 2.765 2.765 2.765 2.969 2.969 2.969 2.969 3.358 3.358 3.358 3.250

2xA252 Double 200 2.469 2.469 2.469 2.469 2.711 2.711 2.711 2.711 2.914 2.914 2.914 2.914 3.296 3.296 3.296 3.296

2xA252 Double 210 2.422 2.422 2.422 2.422 2.664 2.664 2.664 2.664 2.858 2.858 2.858 2.858 3.234 3.234 3.234 3.234

2xA252 Double 220 2.383 2.383 2.383 2.383 2.616 2.616 2.616 2.616 2.808 2.808 2.808 2.808 3.172 3.172 3.172 3.172

2xA252 Double 230 2.339 2.339 2.339 2.339 2.569 2.569 2.569 2.569 2.757 2.757 2.757 2.757 3.120 3.120 3.120 3.120

2xA252 Double 240 2.300 2.300 2.300 2.300 2.527 2.527 2.527 2.527 2.715 2.715 2.715 2.715 3.069 3.069 3.069 3.069

2xA252 Double 250 2.261 2.261 2.261 2.261 2.488 2.488 2.488 2.488 2.672 2.672 2.672 2.672 3.019 3.019 3.019 3.019

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

28 of 72
2.0 Hr
2xA393BOOK
Back to Step 2, R51
Maximum Permissible Span (m)

0.8mm Gauge 0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 - - - - - - - - - - - - - - - -

2xA393 Single 120 - - - - - - - - - - - - - - - -

2xA393 Single 130 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 140 2.453 2.453 2.453 2.453 2.625 2.625 2.625 2.625 2.804 2.804 2.804 2.804 3.069 3.069 3.069 3.069

2xA393 Single 150 2.395 2.395 2.395 2.395 2.569 2.569 2.569 2.569 2.746 2.746 2.746 2.746 3.011 3.011 3.011 3.011

2xA393 Single 160 2.343 2.343 2.343 2.343 2.515 2.515 2.515 2.515 2.688 2.688 2.688 2.688 2.957 2.957 2.957 2.957

2xA393 Single 170 2.292 2.292 2.292 2.292 2.465 2.465 2.465 2.465 2.633 2.633 2.633 2.633 2.903 2.903 2.903 2.903

2xA393 Single 180 2.242 2.242 2.242 2.242 2.418 2.418 2.418 2.418 2.585 2.585 2.585 2.585 2.858 2.858 2.858 2.858

2xA393 Single 190 2.199 2.199 2.199 2.199 2.374 2.374 2.374 2.374 2.538 2.538 2.538 2.538 2.812 2.812 2.812 2.812

2xA393 Single 200 2.157 2.157 2.157 2.157 2.331 2.331 2.331 2.331 2.490 2.490 2.490 2.490 2.769 2.769 2.769 2.769

2xA393 Single 210 2.120 2.120 2.120 2.120 2.288 2.288 2.288 2.288 2.453 2.453 2.453 2.453 2.730 2.730 2.730 2.730

2xA393 Single 220 2.085 2.085 2.085 2.085 2.250 2.250 2.250 2.250 2.414 2.414 2.414 2.414 2.691 2.691 2.691 2.691

2xA393 Single 230 2.049 2.049 2.049 2.049 2.215 2.215 2.215 2.215 2.375 2.375 2.375 2.375 2.657 2.657 2.657 2.657

2xA393 Single 240 2.014 2.014 2.014 2.014 2.180 2.180 2.180 2.180 2.335 2.335 2.335 2.335 2.625 2.625 2.625 2.625

2xA393 Single 250 1.984 1.984 1.984 1.984 2.149 2.149 2.149 2.149 2.304 2.304 2.304 2.304 2.585 2.585 2.585 2.585

2xA393 Double 110 - - - - - - - - - - - - - - - -

2xA393 Double 120 - - - - - - - - - - - - - - - -

2xA393 Double 130 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 140 2.804 2.804 2.804 2.804 3.077 3.077 3.077 3.077 3.279 3.279 3.279 3.164 3.633 3.633 3.633 3.633

2xA393 Double 150 2.734 2.734 2.734 2.734 3.007 3.007 3.007 3.007 3.226 3.226 3.226 3.211 3.554 3.554 3.554 3.554

2xA393 Double 160 2.672 2.672 2.672 2.672 2.938 2.938 2.938 2.938 3.157 3.157 3.157 3.157 3.476 3.476 3.476 3.335

2xA393 Double 170 2.616 2.616 2.616 2.616 2.875 2.875 2.875 2.875 3.085 3.085 3.085 3.085 3.456 3.456 3.456 3.399

2xA393 Double 180 2.562 2.562 2.562 2.562 2.812 2.812 2.812 2.812 3.023 3.023 3.023 3.023 3.414 3.414 3.414 3.414

2xA393 Double 190 2.511 2.511 2.511 2.511 2.757 2.757 2.757 2.757 2.961 2.961 2.961 2.961 3.350 3.350 3.350 3.350

2xA393 Double 200 2.461 2.461 2.461 2.461 2.703 2.703 2.703 2.703 2.907 2.907 2.907 2.907 3.288 3.288 3.288 3.288

2xA393 Double 210 2.418 2.418 2.418 2.418 2.657 2.657 2.657 2.657 2.850 2.850 2.850 2.850 3.226 3.226 3.226 3.226

2xA393 Double 220 2.375 2.375 2.375 2.375 2.608 2.608 2.608 2.608 2.804 2.804 2.804 2.804 3.168 3.168 3.168 3.168

2xA393 Double 230 2.335 2.335 2.335 2.335 2.562 2.562 2.562 2.562 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

2xA393 Double 240 2.294 2.294 2.294 2.294 2.523 2.523 2.523 2.523 2.711 2.711 2.711 2.711 3.062 3.062 3.062 3.062

2xA393 Double 250 2.255 2.255 2.255 2.255 2.484 2.484 2.484 2.484 2.664 2.664 2.664 2.664 3.015 3.015 3.015 3.015

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 29 of 72
THE WHITE BOOK
Contents

Floor deck profile


Deck profile
SMD’s first trapezoidal profile, added to our product range in 1992. Further research and development has
seen our trapezoidal products evolve into the TR+ range. The TR60+ profile enables un-propped spans in
TR60
excess of 3.5m and is available in 0.9mm, 1.0mm and 1.2mm gauges in both S350 and S450 grade steel.

1000 Cover width


158 333
12
60

133

Options
• Reduced concrete volume
• Enhanced speed of installation due to the 1.0m cover width
• Trough stiffeners positioned to ensure central stud position, reducing amount of site checking required
• The steel cross sectional area of this profile makes it the most economical option of the three available profiles
• Soffit ‘Wedge Nut’ fixings available with load capacity of up to 1kN
• Acoustic Robust Solution – Refer Robust Details Handbook (www.robustdetails.com)
• Product options include
HIGH DURABILITY HD steel coating & TAB-Deck™ fibre concrete solution

Concrete volume and weight


Slab Depth Volume of Concrete Weight of Concrete (Normal Weight) Weight of Concrete (Lightweight)
mm m³/m² Wet kN/m² Dry kN/m² Wet kN/m² Dry kN/m²

120 0.086 2.15 2.07 1.73 1.64


130 0.096 2.40 2.31 1.93 1.84
140 0.106 2.65 2.55 2.13 2.03
150 0.116 2.90 2.79 2.33 2.22
175 0.141 3.53 3.39 2.83 2.70
200 0.166 4.15 3.99 3.34 3.17
225 0.191 4.78 4.59 3.84 3.65
250 0.216 5.40 5.19 4.34 4.13
Deflection – This table is based on concrete poured to a constant thickness and does not take account for deflection of the decking or supporting beams (as a guide, to account for the deflection of the
decking, a concrete volume of span/250 should be added to the figures indicated). Concrete Weight – These tables indicate concrete weight only and do not include the weight of decking or reinforcement.
Concrete weights are based on the concrete densities specified in Technical Design Table Notes, see page 4.

Profile properties
Nominal Design Grade Depth of Profile Weight of Profile Weight of Profile Height of Area of Steel Moment of Inertia
Thickness mm Thickness mm N/mm² mm kg/m² kN/m² Neutral Axis mm mm²/m cm4/m
0.9 0.86 350* 60 / 72** 10.03 0.098 33.6 1216 93.5
1.0 0.96 350* 60 / 72** 11.12 0.109 33.6 1355 102.1
1.2 1.16 350* 60 / 72** 13.33 0.131 33.7 1633 119.8
* This design guide is based on S350 grade steel, S450 grade is also available, download SMD Elements® Design software for calculations.
** Depth of profile indicates the nominal depth, ** represents depth including the top re-entrant.

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

30 of 72
THE WHITE BOOK
Back to Step 1

Step 2, TR60+ composite slab graph


Span and slab depth guidance graph
With proposed profile and gauge determined at step 1 on page 5, review the graph below to consider whether Load and Fire rating
govern the design. Construction stage governs (shown dashed) except where solid lines representing the different Load/Fire limits
are shown.

Note: This graph is based on A393 mesh. It may be possible to reduce mesh size by referencing
load/span tables during Step 3.

5.2

5.0 1hr Fire


1.5hr Fire
4.8 2hr Fire

4.6

4.4

4.2

4.0

3.8 *
5kN
Span Length (m)

3.6 7. 5kN
1hr 10 kN Construction
1hr Stage
3.4

3.2 TR60+ 1.2mm

3.0
kN
7.5
N
2.8 7.5k TR60+ 1.0mm
N
10k
Min for 1.5hr Fire

2.6
10kN
Min for 2hr Fire

TR60+ 0.9mm
2.4

2.2

2.0
130 140 150 160 170 180 190 200 210 220 230 240 250
Slab Depth (mm)

1.0 Hour 1.5 Hour 2.0 Hour


Fire Rating Fire Rating Fire Rating
A142 A193 A252 A393 A142 A193 A252 A393 A142 A193 A252 A393
Pg.32 Pg.33 Pg34 Pg.35 Pg.38 Pg.39 Pg.40 Pg.41 Pg.44 Pg.45 Pg.46 Pg.47

* Refer to Note 13 on Page 4

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 31 of 72
1.0 Hr
A142BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 - - - - - - - - - - - -

A142 Single 120 3.219 3.219 2.657 2.391 3.476 3.476 2.726 2.453 3.854 3.854 2.858 2.573

A142 Single 130 3.125 3.125 2.796 2.519 3.383 3.383 2.870 2.585 3.746 3.746 3.011 2.711

A142 Single 140 - - - - - - - - - - - -

A142 Single 150 - - - - - - - - - - - -

A142 Single 160 - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - -

A142 Double 110 - - - - - - - - - - - -

A142 Double 120 3.581 3.581 2.657 2.391 3.867 3.711 2.726 2.453 4.374 3.891 2.858 2.573

A142 Double 130 3.455 3.455 2.796 2.519 3.788 3.788 2.870 2.585 4.238 4.238 3.011 2.711

A142 Double 140 - - - - - - - - - - - -

A142 Double 150 - - - - - - - - - - - -

A142 Double 160 - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

32 of 72
1.0 Hr
A193BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 - - - - - - - - - - - -

A193 Single 120 3.215 3.215 2.738 2.461 3.476 3.476 2.804 2.523 3.850 3.850 2.934 2.641

A193 Single 130 3.125 3.125 2.875 2.589 3.375 3.375 2.945 2.653 3.742 3.742 3.281 2.773

A193 Single 140 3.038 3.038 3.038 2.719 3.288 3.288 3.288 2.781 3.649 3.649 3.484 2.907

A193 Single 150 3.006 3.006 3.006 2.843 3.203 3.203 3.203 2.914 3.562 3.562 3.562 3.046

A193 Single 160 - - - - - - - - - - - -

A193 Single 170 - - - - - - - - - - - -

A193 Single 180 - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - -

A193 Double 110 - - - - - - - - - - - -

A193 Double 120 3.579 3.579 2.738 2.461 3.864 3.812 2.804 2.523 4.370 3.984 2.934 2.641

A193 Double 130 3.451 3.451 2.875 2.589 3.784 3.784 2.945 2.653 4.234 4.234 3.077 2.773

A193 Double 140 3.335 3.335 3.007 2.719 3.660 3.660 3.081 2.781 4.110 4.110 3.219 2.907

A193 Double 150 3.230 3.230 3.141 2.843 3.546 3.546 3.219 2.914 3.996 3.996 3.366 3.046

A193 Double 160 - - - - - - - - - - - -

A193 Double 170 - - - - - - - - - - - -

A193 Double 180 - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 33 of 72
1.0 Hr
A252BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 - - - - - - - - - - - -

A252 Single 120 - - - - - - - - - - - -

A252 Single 130 3.120 3.120 2.953 2.660 3.375 3.375 3.312 2.719 3.738 3.738 3.438 2.835

A252 Single 140 3.038 3.038 3.038 2.781 3.288 3.288 3.288 2.850 3.645 3.645 3.645 2.969

A252 Single 150 3.004 3.004 3.004 2.907 3.203 3.203 3.203 2.976 3.558 3.558 3.558 3.350

A252 Single 160 2.961 2.961 2.961 2.961 3.125 3.125 3.125 3.125 3.480 3.480 3.480 3.480

A252 Single 170 2.883 2.883 2.883 2.883 3.054 3.054 3.054 3.054 3.407 3.407 3.407 3.407

A252 Single 180 2.819 2.819 2.819 2.819 2.992 2.992 2.992 2.992 3.343 3.343 3.343 3.343

A252 Single 190 - - - - - - - - - - - -

A252 Single 200 - - - - - - - - - - - -

A252 Single 210 - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - -

A252 Double 110 - - - - - - - - - - - -

A252 Double 120 - - - - - - - - - - - -

A252 Double 130 3.447 3.447 2.953 2.660 3.781 3.781 3.023 2.719 4.230 4.230 3.149 2.835

A252 Double 140 3.331 3.331 3.085 2.781 3.657 3.657 3.149 2.850 4.106 4.106 3.288 2.969

A252 Double 150 3.226 3.226 3.211 2.907 3.542 3.542 3.288 2.976 3.992 3.992 3.422 3.100

A252 Double 160 3.129 3.129 3.129 3.023 3.438 3.438 3.407 3.093 3.936 3.936 3.554 3.219

A252 Double 170 3.040 3.040 3.040 3.040 3.341 3.341 3.341 3.203 3.895 3.895 3.672 3.335

A252 Double 180 2.957 2.957 2.957 2.957 3.253 3.253 3.253 3.253 3.792 3.792 3.792 3.453

A252 Double 190 - - - - - - - - - - - -

A252 Double 200 - - - - - - - - - - - -

A252 Double 210 - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

34 of 72
1.0 Hr
A393BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 - - - - - - - - - - - -

A393 Single 120 - - - - - - - - - - - -

A393 Single 130 3.116 3.116 3.116 2.812 3.366 3.366 3.366 2.866 3.730 3.730 3.730 2.969

A393 Single 140 3.031 3.031 3.031 2.926 3.281 3.281 3.281 2.984 3.637 3.637 3.637 3.484

A393 Single 150 2.998 2.998 2.998 2.998 3.195 3.195 3.195 3.195 3.550 3.550 3.550 3.550

A393 Single 160 2.953 2.953 2.953 2.953 3.124 3.124 3.124 3.124 3.472 3.472 3.472 3.472

A393 Single 170 2.876 2.876 2.876 2.876 3.050 3.050 3.050 3.050 3.403 3.403 3.403 3.403

A393 Single 180 2.812 2.812 2.812 2.812 2.984 2.984 2.984 2.984 3.335 3.335 3.335 3.335

A393 Single 190 2.750 2.750 2.750 2.750 2.922 2.922 2.922 2.922 3.277 3.277 3.277 3.277

A393 Single 200 2.688 2.688 2.688 2.688 2.866 2.866 2.866 2.866 3.219 3.219 3.219 3.219

A393 Single 210 2.608 2.608 2.608 2.608 2.812 2.812 2.812 2.812 3.168 3.168 3.168 3.168

A393 Single 220 2.507 2.507 2.507 2.507 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

A393 Single 230 2.414 2.414 2.414 2.414 2.688 2.688 2.688 2.688 3.069 3.069 3.069 3.069

A393 Single 240 2.327 2.327 2.327 2.327 2.664 2.664 2.664 2.664 3.027 3.027 3.027 3.027

A393 Single 250 2.250 2.250 2.250 2.250 2.608 2.608 2.608 2.608 2.984 2.984 2.984 2.984

A393 Double 110 - - - - - - - - - - - -

A393 Double 120 - - - - - - - - - - - -

A393 Double 130 3.438 3.438 3.120 2.812 3.771 3.771 3.180 2.866 4.219 4.219 3.296 2.969

A393 Double 140 3.323 3.323 3.242 2.926 3.647 3.647 3.304 2.984 4.096 4.096 3.422 3.093

A393 Double 150 3.219 3.219 3.219 3.038 3.534 3.534 3.430 3.100 3.984 3.984 3.554 3.219

A393 Double 160 3.122 3.122 3.122 3.122 3.430 3.430 3.430 3.203 3.930 3.930 3.664 3.319

A393 Double 170 3.034 3.034 3.034 3.034 3.335 3.335 3.335 3.296 3.885 3.885 3.765 3.422

A393 Double 180 2.951 2.951 2.951 2.951 3.246 3.246 3.246 3.246 3.784 3.784 3.784 3.538

A393 Double 190 2.875 2.875 2.875 2.875 3.162 3.162 3.162 3.162 3.691 3.691 3.691 3.691

A393 Double 200 2.804 2.804 2.804 2.804 3.085 3.085 3.085 3.085 3.602 3.602 3.602 3.602

A393 Double 210 2.738 2.738 2.738 2.738 3.013 3.013 3.013 3.013 3.519 3.519 3.519 3.519

A393 Double 220 2.674 2.674 2.674 2.674 2.945 2.945 2.945 2.945 3.443 3.443 3.443 3.443

A393 Double 230 2.616 2.616 2.616 2.616 2.881 2.881 2.881 2.881 3.370 3.370 3.370 3.370

A393 Double 240 2.560 2.560 2.560 2.560 2.821 2.821 2.821 2.821 3.302 3.302 3.302 3.302

A393 Double 250 2.507 2.507 2.507 2.507 2.765 2.765 2.765 2.765 3.238 3.238 3.238 3.238

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 35 of 72
1.0 Hr
BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)
2xA252

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 - - - - - - - - - - - -

2xA252 Single 120 - - - - - - - - - - - -

2xA252 Single 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 140 3.023 3.023 3.023 3.023 3.273 3.273 3.273 3.273 3.629 3.629 3.629 3.629

2xA252 Single 150 2.994 2.994 2.994 2.994 3.191 3.191 3.191 3.191 3.546 3.546 3.546 3.546

2xA252 Single 160 2.945 2.945 2.945 2.945 3.116 3.116 3.116 3.116 3.469 3.469 3.469 3.469

2xA252 Single 170 2.875 2.875 2.875 2.875 3.046 3.046 3.046 3.046 3.399 3.399 3.399 3.399

2xA252 Single 180 2.808 2.808 2.808 2.808 2.984 2.984 2.984 2.984 3.331 3.331 3.331 3.331

2xA252 Single 190 2.746 2.746 2.746 2.746 2.922 2.922 2.922 2.922 3.273 3.273 3.273 3.273

2xA252 Single 200 2.688 2.688 2.688 2.688 2.862 2.862 2.862 2.862 3.215 3.215 3.215 3.215

2xA252 Single 210 2.600 2.600 2.600 2.600 2.808 2.808 2.808 2.808 3.164 3.164 3.164 3.164

2xA252 Single 220 2.500 2.500 2.500 2.500 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

2xA252 Single 230 2.407 2.407 2.407 2.407 2.711 2.711 2.711 2.711 3.069 3.069 3.069 3.069

2xA252 Single 240 2.327 2.327 2.327 2.327 2.664 2.664 2.664 2.664 3.023 3.023 3.023 3.023

2xA252 Single 250 2.242 2.242 2.242 2.242 2.616 2.616 2.616 2.616 2.984 2.984 2.984 2.984

2xA252 Double 110 - - - - - - - - - - - -

2xA252 Double 120 - - - - - - - - - - - -

2xA252 Double 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 140 3.317 3.317 3.317 3.149 3.641 3.641 3.546 3.203 4.089 4.089 4.000 3.296

2xA252 Double 150 3.213 3.213 3.213 3.213 3.527 3.527 3.527 3.304 3.976 3.976 3.765 3.407

2xA252 Double 160 3.116 3.116 3.116 3.116 3.424 3.424 3.424 3.375 3.925 3.925 3.843 3.484

2xA252 Double 170 3.029 3.029 3.029 3.029 3.327 3.327 3.327 3.327 3.879 3.879 3.879 3.562

2xA252 Double 180 2.947 2.947 2.947 2.947 3.240 3.240 3.240 3.240 3.777 3.777 3.777 3.649

2xA252 Double 190 2.870 2.870 2.870 2.870 3.157 3.157 3.157 3.157 3.684 3.684 3.684 3.684

2xA252 Double 200 2.800 2.800 2.800 2.800 3.081 3.081 3.081 3.081 3.596 3.596 3.596 3.596

2xA252 Double 210 2.734 2.734 2.734 2.734 3.009 3.009 3.009 3.009 3.515 3.515 3.515 3.515

2xA252 Double 220 2.670 2.670 2.670 2.670 2.941 2.941 2.941 2.941 3.438 3.438 3.438 3.438

2xA252 Double 230 2.612 2.612 2.612 2.612 2.877 2.877 2.877 2.877 3.366 3.366 3.366 3.366

2xA252 Double 240 2.556 2.556 2.556 2.556 2.817 2.817 2.817 2.817 3.298 3.298 3.298 3.298

2xA252 Double 250 2.505 2.505 2.505 2.505 2.761 2.761 2.761 2.761 3.234 3.234 3.234 3.234

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

36 of 72
1.0 Hr
BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

2xA393
0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 - - - - - - - - - - - -

2xA393 Single 120 - - - - - - - - - - - -

2xA393 Single 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 150 2.984 2.984 2.984 2.984 3.180 3.180 3.180 3.180 3.531 3.531 3.531 3.531

2xA393 Single 160 2.938 2.938 2.938 2.938 3.108 3.108 3.108 3.108 3.457 3.457 3.457 3.457

2xA393 Single 170 2.866 2.866 2.866 2.866 3.038 3.038 3.038 3.038 3.387 3.387 3.387 3.387

2xA393 Single 180 2.796 2.796 2.796 2.796 2.969 2.969 2.969 2.969 3.323 3.323 3.323 3.323

2xA393 Single 190 2.734 2.734 2.734 2.734 2.875 2.875 2.875 2.875 3.261 3.261 3.261 3.261

2xA393 Single 200 2.680 2.680 2.680 2.680 2.854 2.854 2.854 2.854 3.207 3.207 3.207 3.207

2xA393 Single 210 2.585 2.585 2.585 2.585 2.800 2.800 2.800 2.800 3.153 3.153 3.153 3.153

2xA393 Single 220 2.484 2.484 2.484 2.484 2.750 2.750 2.750 2.750 3.104 3.104 3.104 3.104

2xA393 Single 230 2.391 2.391 2.391 2.391 2.703 2.703 2.703 2.703 3.062 3.062 3.062 3.062

2xA393 Single 240 2.312 2.312 2.312 2.312 2.657 2.657 2.657 2.657 3.015 3.015 3.015 3.015

2xA393 Single 250 2.234 2.234 2.234 2.234 2.608 2.608 2.608 2.608 2.976 2.976 2.976 2.976

2xA393 Double 110 - - - - - - - - - - - -

2xA393 Double 120 - - - - - - - - - - - -

2xA393 Double 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 150 3.197 3.197 3.197 3.197 3.511 3.511 3.511 3.511 3.961 3.961 3.961 3.657

2xA393 Double 160 3.102 3.102 3.102 3.102 3.408 3.408 3.408 3.408 3.912 3.912 3.912 3.719

2xA393 Double 170 3.015 3.015 3.015 3.015 3.315 3.315 3.315 3.315 3.862 3.862 3.862 3.750

2xA393 Double 180 2.934 2.934 2.934 2.934 3.226 3.226 3.226 3.226 3.763 3.763 3.763 3.763

2xA393 Double 190 2.858 2.858 2.858 2.858 3.145 3.145 3.145 3.145 3.672 3.672 3.672 3.672

2xA393 Double 200 2.788 2.788 2.788 2.788 3.069 3.069 3.069 3.069 3.585 3.585 3.585 3.585

2xA393 Double 210 2.722 2.722 2.722 2.722 2.998 2.998 2.998 2.998 3.503 3.503 3.503 3.503

2xA393 Double 220 2.662 2.662 2.662 2.662 2.930 2.930 2.930 2.930 3.426 3.426 3.426 3.426

2xA393 Double 230 2.604 2.604 2.604 2.604 2.868 2.868 2.868 2.868 3.354 3.354 3.354 3.354

2xA393 Double 240 2.548 2.548 2.548 2.548 2.808 2.808 2.808 2.808 3.288 3.288 3.288 3.288

2xA393 Double 250 2.496 2.496 2.496 2.496 2.753 2.753 2.753 2.753 3.222 3.222 3.222 3.222

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 37 of 72
1.5 Hr
A142BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 - - - - - - - - - - - -

A142 Single 120 - - - - - - - - - - - -

A142 Single 130 3.125 3.125 2.343 2.116 3.383 3.383 2.403 2.168 3.746 3.742 2.515 2.273

A142 Single 140 - - - - - - - - - - - -

A142 Single 150 - - - - - - - - - - - -

A142 Single 160 - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - -

A142 Double 110 - - - - - - - - - - - -

A142 Double 120 - - - - - - - - - - - -

A142 Double 130 3.455 3.149 2.343 2.116 3.788 3.226 2.403 2.168 4.238 3.375 2.515 2.273

A142 Double 140 - - - - - - - - - - - -

A142 Double 150 - - - - - - - - - - - -

A142 Double 160 - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

38 of 72
1.5 Hr
A193BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 - - - - - - - - - - - -

A193 Single 120 - - - - - - - - - - - -

A193 Single 130 3.125 3.125 2.438 2.199 3.375 3.375 2.492 2.250 3.742 3.742 2.600 2.346

A193 Single 140 3.038 3.038 2.538 2.292 3.288 3.288 2.593 2.346 3.649 3.649 2.707 2.445

A193 Single 150 3.006 3.006 2.641 2.391 3.203 3.203 2.703 2.445 3.562 3.562 2.815 2.550

A193 Single 160 - - - - - - - - - - - -

A193 Single 170 - - - - - - - - - - - -

A193 Single 180 - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - -

A193 Double 110 - - - - - - - - - - - -

A193 Double 120 - - - - - - - - - - - -

A193 Double 130 3.451 3.273 2.438 2.199 3.784 3.350 2.492 2.250 4.234 3.492 2.600 2.346

A193 Double 140 3.335 3.335 2.538 2.292 3.660 3.453 2.593 2.346 4.110 3.600 2.707 2.445

A193 Double 150 3.230 3.230 2.641 2.391 3.546 3.546 2.703 2.445 3.996 3.711 2.815 2.550

A193 Double 160 - - - - - - - - - - - -

A193 Double 170 - - - - - - - - - - - -

A193 Double 180 - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 39 of 72
1.5 Hr
A252BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 - - - - - - - - - - - -

A252 Single 120 - - - - - - - - - - - -

A252 Single 130 3.120 3.120 2.538 2.288 3.375 3.375 2.589 2.335 3.738 3.738 2.688 2.426

A252 Single 140 3.038 3.038 2.626 2.375 3.288 3.288 2.684 2.426 3.645 3.645 2.788 2.523

A252 Single 150 3.004 3.004 2.726 2.469 3.203 3.203 2.781 2.523 3.558 3.558 2.895 2.624

A252 Single 160 2.961 2.961 2.827 2.565 3.125 3.125 2.887 2.620 3.480 3.480 3.000 2.726

A252 Single 170 2.883 2.883 2.883 2.672 3.054 3.054 3.000 2.726 3.407 3.407 3.407 2.835

A252 Single 180 2.819 2.819 2.819 2.777 2.992 2.992 2.992 2.835 3.343 3.343 3.343 2.945

A252 Single 190 - - - - - - - - - - - -

A252 Single 200 - - - - - - - - - - - -

A252 Single 210 - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - -

A252 Double 110 - - - - - - - - - - - -

A252 Double 120 - - - - - - - - - - - -

A252 Double 130 3.447 3.407 2.538 2.288 3.781 3.476 2.589 2.335 4.230 3.608 2.688 2.426

A252 Double 140 3.331 3.331 2.626 2.375 3.657 3.569 2.684 2.426 4.106 4.000 2.788 2.523

A252 Double 150 3.226 3.226 2.726 2.469 3.542 3.542 2.781 2.523 3.992 3.819 2.895 2.624

A252 Double 160 3.129 3.129 2.827 2.565 3.438 3.438 2.887 2.620 3.936 3.922 3.000 2.726

A252 Double 170 3.040 3.040 2.938 2.672 3.341 3.341 3.000 2.726 3.895 3.895 3.116 2.835

A252 Double 180 2.957 2.957 2.957 2.777 3.253 3.253 3.108 2.835 3.792 3.792 3.234 2.945

A252 Double 190 - - - - - - - - - - - -

A252 Double 200 - - - - - - - - - - - -

A252 Double 210 - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

40 of 72
1.5 Hr
A393BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 - - - - - - - - - - - -

A393 Single 120 - - - - - - - - - - - -

A393 Single 130 3.116 3.116 2.734 2.465 3.366 3.366 2.777 2.507 3.730 3.730 2.866 2.585

A393 Single 140 3.031 3.031 2.819 2.546 3.281 3.281 2.866 2.593 3.637 3.637 2.961 2.672

A393 Single 150 2.998 2.998 2.907 2.633 3.195 3.195 2.961 2.680 3.550 3.550 3.550 2.769

A393 Single 160 2.953 2.953 2.953 2.719 3.124 3.124 3.124 2.773 3.472 3.472 3.472 2.866

A393 Single 170 2.876 2.876 2.876 2.819 3.050 3.050 3.050 2.866 3.403 3.403 3.403 2.969

A393 Single 180 2.812 2.812 2.812 2.812 2.984 2.984 2.984 2.984 3.335 3.335 3.335 3.335

A393 Single 190 2.750 2.750 2.750 2.750 2.922 2.922 2.922 2.922 3.277 3.277 3.277 3.277

A393 Single 200 2.688 2.688 2.688 2.688 2.866 2.866 2.866 2.866 3.219 3.219 3.219 3.219

A393 Single 210 2.608 2.608 2.608 2.608 2.812 2.812 2.812 2.812 3.168 3.168 3.168 3.168

A393 Single 220 2.507 2.507 2.507 2.507 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

A393 Single 230 2.414 2.414 2.414 2.414 2.688 2.688 2.688 2.688 3.069 3.069 3.069 3.069

A393 Single 240 2.327 2.327 2.327 2.327 2.664 2.664 2.664 2.664 3.027 3.027 3.027 3.027

A393 Single 250 2.250 2.250 2.250 2.250 2.608 2.608 2.608 2.608 2.984 2.984 2.984 2.984

A393 Double 110 - - - - - - - - - - - -

A393 Double 120 - - - - - - - - - - - -

A393 Double 130 3.438 3.438 2.734 2.465 3.771 3.734 2.777 2.507 4.219 4.219 2.866 2.585

A393 Double 140 3.323 3.323 2.819 2.546 3.647 3.647 2.866 2.593 4.096 4.096 2.961 2.672

A393 Double 150 3.219 3.219 2.907 2.633 3.534 3.534 2.961 2.680 3.984 3.984 3.054 2.769

A393 Double 160 3.122 3.122 3.000 2.719 3.430 3.430 3.054 2.773 3.930 3.930 3.157 2.866

A393 Double 170 3.034 3.034 3.034 2.819 3.335 3.335 3.157 2.866 3.885 3.885 3.265 2.969

A393 Double 180 2.951 2.951 2.951 2.951 3.246 3.246 3.246 2.976 3.784 3.784 3.366 3.062

A393 Double 190 2.875 2.875 2.875 2.875 3.162 3.162 3.162 3.125 3.691 3.691 3.469 3.164

A393 Double 200 2.804 2.804 2.804 2.804 3.085 3.085 3.085 3.085 3.602 3.602 3.602 3.296

A393 Double 210 2.738 2.738 2.738 2.738 3.013 3.013 3.013 3.013 3.519 3.519 3.519 3.461

A393 Double 220 2.674 2.674 2.674 2.674 2.945 2.945 2.945 2.945 3.443 3.443 3.443 3.443

A393 Double 230 2.616 2.616 2.616 2.616 2.881 2.881 2.881 2.881 3.370 3.370 3.370 3.370

A393 Double 240 2.560 2.560 2.560 2.560 2.821 2.821 2.821 2.821 3.302 3.302 3.302 3.302

A393 Double 250 2.507 2.507 2.507 2.507 2.765 2.765 2.765 2.765 3.238 3.238 3.238 3.238

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 41 of 72
1.5 Hr
BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)
2xA252

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 - - - - - - - - - - - -

2xA252 Single 120 - - - - - - - - - - - -

2xA252 Single 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 140 3.023 3.023 3.023 2.827 3.273 3.273 3.273 2.866 3.629 3.629 3.629 2.938

2xA252 Single 150 2.994 2.994 2.994 2.895 3.191 3.191 3.191 2.938 3.546 3.546 3.546 3.515

2xA252 Single 160 2.945 2.945 2.945 2.945 3.116 3.116 3.116 3.116 3.469 3.469 3.469 3.469

2xA252 Single 170 2.875 2.875 2.875 2.875 3.046 3.046 3.046 3.046 3.399 3.399 3.399 3.399

2xA252 Single 180 2.808 2.808 2.808 2.808 2.984 2.984 2.984 2.984 3.331 3.331 3.331 3.331

2xA252 Single 190 2.746 2.746 2.746 2.746 2.922 2.922 2.922 2.922 3.273 3.273 3.273 3.273

2xA252 Single 200 2.688 2.688 2.688 2.688 2.862 2.862 2.862 2.862 3.215 3.215 3.215 3.215

2xA252 Single 210 2.600 2.600 2.600 2.600 2.808 2.808 2.808 2.808 3.164 3.164 3.164 3.164

2xA252 Single 220 2.500 2.500 2.500 2.500 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

2xA252 Single 230 2.407 2.407 2.407 2.407 2.711 2.711 2.711 2.711 3.069 3.069 3.069 3.069

2xA252 Single 240 2.327 2.327 2.327 2.327 2.664 2.664 2.664 2.664 3.023 3.023 3.023 3.023

2xA252 Single 250 2.242 2.242 2.242 2.242 2.616 2.616 2.616 2.616 2.984 2.984 2.984 2.984

2xA252 Double 110 - - - - - - - - - - - -

2xA252 Double 120 - - - - - - - - - - - -

2xA252 Double 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 140 3.317 3.317 3.133 2.827 3.641 3.641 3.172 2.866 4.089 4.089 3.250 2.938

2xA252 Double 150 3.213 3.213 3.195 2.895 3.527 3.527 3.242 2.938 3.976 3.976 3.327 3.015

2xA252 Double 160 3.116 3.116 3.116 2.969 3.424 3.424 3.319 3.007 3.925 3.925 3.407 3.093

2xA252 Double 170 3.029 3.029 3.029 3.029 3.327 3.327 3.327 3.085 3.879 3.879 3.492 3.172

2xA252 Double 180 2.947 2.947 2.947 2.947 3.240 3.240 3.240 3.164 3.777 3.777 3.577 3.257

2xA252 Double 190 2.870 2.870 2.870 2.870 3.157 3.157 3.157 3.157 3.684 3.684 3.657 3.335

2xA252 Double 200 2.800 2.800 2.800 2.800 3.081 3.081 3.081 3.081 3.596 3.596 3.596 3.422

2xA252 Double 210 2.734 2.734 2.734 2.734 3.009 3.009 3.009 3.009 3.515 3.515 3.515 3.515

2xA252 Double 220 2.670 2.670 2.670 2.670 2.941 2.941 2.941 2.941 3.438 3.438 3.438 3.438

2xA252 Double 230 2.612 2.612 2.612 2.612 2.877 2.877 2.877 2.877 3.366 3.366 3.366 3.366

2xA252 Double 240 2.556 2.556 2.556 2.556 2.817 2.817 2.817 2.817 3.298 3.298 3.298 3.298

2xA252 Double 250 2.505 2.505 2.505 2.505 2.761 2.761 2.761 2.761 3.234 3.234 3.234 3.234

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

42 of 72
1.5 Hr
BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

2xA393
0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 - - - - - - - - - - - -

2xA393 Single 120 - - - - - - - - - - - -

2xA393 Single 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 150 2.984 2.984 2.984 2.984 3.180 3.180 3.180 3.180 3.531 3.531 3.531 3.531

2xA393 Single 160 2.938 2.938 2.938 2.938 3.108 3.108 3.108 3.108 3.457 3.457 3.457 3.457

2xA393 Single 170 2.866 2.866 2.866 2.866 3.038 3.038 3.038 3.038 3.387 3.387 3.387 3.387

2xA393 Single 180 2.796 2.796 2.796 2.796 2.969 2.969 2.969 2.969 3.323 3.323 3.323 3.323

2xA393 Single 190 2.734 2.734 2.734 2.734 2.875 2.875 2.875 2.875 3.261 3.261 3.261 3.261

2xA393 Single 200 2.680 2.680 2.680 2.680 2.854 2.854 2.854 2.854 3.207 3.207 3.207 3.207

2xA393 Single 210 2.585 2.585 2.585 2.585 2.800 2.800 2.800 2.800 3.153 3.153 3.153 3.153

2xA393 Single 220 2.484 2.484 2.484 2.484 2.750 2.750 2.750 2.750 3.104 3.104 3.104 3.104

2xA393 Single 230 2.391 2.391 2.391 2.391 2.703 2.703 2.703 2.703 3.062 3.062 3.062 3.062

2xA393 Single 240 2.312 2.312 2.312 2.312 2.657 2.657 2.657 2.657 3.015 3.015 3.015 3.015

2xA393 Single 250 2.234 2.234 2.234 2.234 2.608 2.608 2.608 2.608 2.976 2.976 2.976 2.976

2xA393 Double 110 - - - - - - - - - - - -

2xA393 Double 120 - - - - - - - - - - - -

2xA393 Double 130 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 150 3.197 3.197 3.197 3.197 3.511 3.511 3.511 3.242 3.961 3.961 3.657 3.304

2xA393 Double 160 3.102 3.102 3.102 3.102 3.408 3.408 3.408 3.312 3.912 3.912 3.726 3.375

2xA393 Double 170 3.015 3.015 3.015 3.015 3.315 3.315 3.315 3.315 3.862 3.862 3.796 3.453

2xA393 Double 180 2.934 2.934 2.934 2.934 3.226 3.226 3.226 3.226 3.763 3.763 3.763 3.515

2xA393 Double 190 2.858 2.858 2.858 2.858 3.145 3.145 3.145 3.145 3.672 3.672 3.672 3.569

2xA393 Double 200 2.788 2.788 2.788 2.788 3.069 3.069 3.069 3.069 3.585 3.585 3.585 3.585

2xA393 Double 210 2.722 2.722 2.722 2.722 2.998 2.998 2.998 2.998 3.503 3.503 3.503 3.503

2xA393 Double 220 2.662 2.662 2.662 2.662 2.930 2.930 2.930 2.930 3.426 3.426 3.426 3.426

2xA393 Double 230 2.604 2.604 2.604 2.604 2.868 2.868 2.868 2.868 3.354 3.354 3.354 3.354

2xA393 Double 240 2.548 2.548 2.548 2.548 2.808 2.808 2.808 2.808 3.288 3.288 3.288 3.288

2xA393 Double 250 2.496 2.496 2.496 2.496 2.753 2.753 2.753 2.753 3.222 3.222 3.222 3.222

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 43 of 72
2.0 Hr
A142BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 - - - - - - - - - - - -

A142 Single 120 - - - - - - - - - - - -

A142 Single 130 - - - - - - - - - - - -

A142 Single 140 - - - - - - - - - - - -

A142 Single 150 - - - - - - - - - - - -

A142 Single 160 - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - -

A142 Double 110 - - - - - - - - - - - -

A142 Double 120 - - - - - - - - - - - -

A142 Double 130 - - - - - - - - - - - -

A142 Double 140 - - - - - - - - - - - -

A142 Double 150 - - - - - - - - - - - -

A142 Double 160 - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

44 of 72
2.0 Hr
A193BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 - - - - - - - - - - - -

A193 Single 120 - - - - - - - - - - - -

A193 Single 130 - - - - - - - - - - - -

A193 Single 140 3.038 3.038 2.281 2.062 3.288 3.288 2.327 2.104 3.649 3.608 2.414 2.184

A193 Single 150 3.006 3.006 2.366 2.145 3.203 3.203 2.414 2.188 3.562 3.562 2.503 2.269

A193 Single 160 - - - - - - - - - - - -

A193 Single 170 - - - - - - - - - - - -

A193 Single 180 - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - -

A193 Double 110 - - - - - - - - - - - -

A193 Double 120 - - - - - - - - - - - -

A193 Double 130 - - - - - - - - - - - -

A193 Double 140 3.335 3.031 2.281 2.062 3.660 3.093 2.327 2.104 4.110 3.203 2.414 2.184

A193 Double 150 3.230 3.116 2.366 2.145 3.546 3.180 2.414 2.188 3.996 3.296 2.503 2.269

A193 Double 160 - - - - - - - - - - - -

A193 Double 170 - - - - - - - - - - - -

A193 Double 180 - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 45 of 72
2.0 Hr
A252BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 - - - - - - - - - - - -

A252 Single 120 - - - - - - - - - - - -

A252 Single 130 - - - - - - - - - - - -

A252 Single 140 3.038 3.038 2.387 2.157 3.288 3.288 2.430 2.195 3.645 3.645 2.507 2.269

A252 Single 150 3.004 3.004 2.469 2.234 3.203 3.203 2.511 2.273 3.558 3.558 2.593 2.350

A252 Single 160 2.961 2.961 2.554 2.319 3.125 3.125 2.600 2.358 3.480 3.480 2.688 2.438

A252 Single 170 2.883 2.883 2.649 2.410 3.054 3.054 2.695 2.453 3.407 3.407 2.788 2.531

A252 Single 180 2.819 2.819 2.781 2.538 2.992 2.992 2.796 2.546 3.343 3.343 2.891 2.633

A252 Single 190 - - - - - - - - - - - -

A252 Single 200 - - - - - - - - - - - -

A252 Single 210 - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - -

A252 Double 110 - - - - - - - - - - - -

A252 Double 120 - - - - - - - - - - - -

A252 Double 130 - - - - - - - - - - - -

A252 Double 140 3.331 3.172 2.387 2.157 3.657 3.226 2.430 2.195 4.106 3.335 2.507 2.269

A252 Double 150 3.226 3.226 2.469 2.234 3.542 3.304 2.511 2.273 3.992 3.414 2.593 2.350

A252 Double 160 3.129 3.129 2.554 2.319 3.438 3.399 2.600 2.358 3.936 3.507 2.688 2.438

A252 Double 170 3.040 3.040 2.649 2.410 3.341 3.341 2.695 2.453 3.895 3.608 2.788 2.531

A252 Double 180 2.957 2.957 2.781 2.538 3.253 3.253 2.796 2.546 3.792 3.719 2.891 2.633

A252 Double 190 - - - - - - - - - - - -

A252 Double 200 - - - - - - - - - - - -

A252 Double 210 - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

46 of 72
2.0 Hr
A393BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 - - - - - - - - - - - -

A393 Single 120 - - - - - - - - - - - -

A393 Single 130 - - - - - - - - - - - -

A393 Single 140 3.031 3.031 2.600 2.350 3.281 3.281 2.633 2.383 3.637 3.637 2.703 2.445

A393 Single 150 2.998 2.998 2.672 2.422 3.195 3.195 2.711 2.453 3.550 3.550 2.781 2.523

A393 Single 160 2.953 2.953 2.765 2.511 3.124 3.124 2.788 2.531 3.472 3.472 2.866 2.600

A393 Single 170 2.876 2.876 2.876 2.641 3.050 3.050 2.922 2.657 3.403 3.403 2.961 2.688

A393 Single 180 2.812 2.812 2.812 2.788 2.984 2.984 2.984 2.796 3.335 3.335 3.335 2.823

A393 Single 190 2.750 2.750 2.750 2.750 2.922 2.922 2.922 2.922 3.277 3.277 3.277 2.961

A393 Single 200 2.688 2.688 2.688 2.688 2.866 2.866 2.866 2.866 3.219 3.219 3.219 3.219

A393 Single 210 2.608 2.608 2.608 2.608 2.812 2.812 2.812 2.812 3.168 3.168 3.168 3.168

A393 Single 220 2.507 2.507 2.507 2.507 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

A393 Single 230 2.414 2.414 2.414 2.414 2.688 2.688 2.688 2.688 3.069 3.069 3.069 3.069

A393 Single 240 2.327 2.327 2.327 2.327 2.664 2.664 2.664 2.664 3.027 3.027 3.027 3.027

A393 Single 250 2.250 2.250 2.250 2.250 2.608 2.608 2.608 2.608 2.984 2.984 2.984 2.984

A393 Double 110 - - - - - - - - - - - -

A393 Double 120 - - - - - - - - - - - -

A393 Double 130 - - - - - - - - - - - -

A393 Double 140 3.323 3.323 2.600 2.350 3.647 3.500 2.633 2.383 4.096 4.031 2.703 2.445

A393 Double 150 3.219 3.219 2.672 2.422 3.534 3.534 2.711 2.453 3.984 3.664 2.781 2.523

A393 Double 160 3.122 3.122 2.765 2.511 3.430 3.430 2.788 2.531 3.930 3.742 2.866 2.600

A393 Double 170 3.034 3.034 2.907 2.641 3.335 3.335 2.922 2.657 3.885 3.835 2.961 2.688

A393 Double 180 2.951 2.951 2.951 2.788 3.246 3.246 3.069 2.796 3.784 3.784 3.100 2.823

A393 Double 190 2.875 2.875 2.875 2.875 3.162 3.162 3.162 2.945 3.691 3.691 3.250 2.961

A393 Double 200 2.804 2.804 2.804 2.804 3.085 3.085 3.085 3.085 3.602 3.602 3.407 3.116

A393 Double 210 2.738 2.738 2.738 2.738 3.013 3.013 3.013 3.013 3.519 3.519 3.519 3.296

A393 Double 220 2.674 2.674 2.674 2.674 2.945 2.945 2.945 2.945 3.443 3.443 3.443 3.443

A393 Double 230 2.616 2.616 2.616 2.616 2.881 2.881 2.881 2.881 3.370 3.370 3.370 3.370

A393 Double 240 2.560 2.560 2.560 2.560 2.821 2.821 2.821 2.821 3.302 3.302 3.302 3.302

A393 Double 250 2.507 2.507 2.507 2.507 2.765 2.765 2.765 2.765 3.238 3.238 3.238 3.238

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 47 of 72
2.0 Hr
BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)
2xA252

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


THE WHITE

Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 - - - - - - - - - - - -

2xA252 Single 120 - - - - - - - - - - - -

2xA252 Single 130 - - - - - - - - - - - -

2xA252 Single 140 3.023 3.023 2.907 2.625 3.273 3.273 2.938 2.657 3.629 3.629 3.000 2.711

2xA252 Single 150 2.994 2.994 2.994 2.711 3.191 3.191 3.191 2.742 3.546 3.546 3.546 2.796

2xA252 Single 160 2.945 2.945 2.945 2.769 3.116 3.116 3.116 2.804 3.469 3.469 3.469 2.858

2xA252 Single 170 2.875 2.875 2.875 2.835 3.046 3.046 3.046 2.866 3.399 3.399 3.399 2.930

2xA252 Single 180 2.808 2.808 2.808 2.808 2.984 2.984 2.984 2.938 3.331 3.331 3.331 3.331

2xA252 Single 190 2.746 2.746 2.746 2.746 2.922 2.922 2.922 2.922 3.273 3.273 3.273 3.273

2xA252 Single 200 2.688 2.688 2.688 2.688 2.862 2.862 2.862 2.862 3.215 3.215 3.215 3.215

2xA252 Single 210 2.600 2.600 2.600 2.600 2.808 2.808 2.808 2.808 3.164 3.164 3.164 3.164

2xA252 Single 220 2.500 2.500 2.500 2.500 2.757 2.757 2.757 2.757 3.116 3.116 3.116 3.116

2xA252 Single 230 2.407 2.407 2.407 2.407 2.711 2.711 2.711 2.711 3.069 3.069 3.069 3.069

2xA252 Single 240 2.327 2.327 2.327 2.327 2.664 2.664 2.664 2.664 3.023 3.023 3.023 3.023

2xA252 Single 250 2.242 2.242 2.242 2.242 2.616 2.616 2.616 2.616 2.984 2.984 2.984 2.984

2xA252 Double 110 - - - - - - - - - - - -

2xA252 Double 120 - - - - - - - - - - - -

2xA252 Double 130 - - - - - - - - - - - -

2xA252 Double 140 3.317 3.317 2.907 2.625 3.641 3.641 2.938 2.657 4.089 4.089 3.000 2.711

2xA252 Double 150 3.213 3.213 3.000 2.711 3.527 3.527 3.031 2.742 3.976 3.976 3.093 2.796

2xA252 Double 160 3.116 3.116 3.054 2.769 3.424 3.424 3.085 2.804 3.925 3.925 3.157 2.858

2xA252 Double 170 3.029 3.029 3.029 2.835 3.327 3.327 3.157 2.866 3.879 3.879 3.226 2.930

2xA252 Double 180 2.947 2.947 2.947 2.914 3.240 3.240 3.226 2.938 3.777 3.777 3.296 3.007

2xA252 Double 190 2.870 2.870 2.870 2.870 3.157 3.157 3.157 3.046 3.684 3.684 3.375 3.077

2xA252 Double 200 2.800 2.800 2.800 2.800 3.081 3.081 3.081 3.081 3.596 3.596 3.507 3.203

2xA252 Double 210 2.734 2.734 2.734 2.734 3.009 3.009 3.009 3.009 3.515 3.515 3.515 3.350

2xA252 Double 220 2.670 2.670 2.670 2.670 2.941 2.941 2.941 2.941 3.438 3.438 3.438 3.438

2xA252 Double 230 2.612 2.612 2.612 2.612 2.877 2.877 2.877 2.877 3.366 3.366 3.366 3.366

2xA252 Double 240 2.556 2.556 2.556 2.556 2.817 2.817 2.817 2.817 3.298 3.298 3.298 3.298

2xA252 Double 250 2.505 2.505 2.505 2.505 2.761 2.761 2.761 2.761 3.234 3.234 3.234 3.234

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

48 of 72
2.0 Hr
BOOK
Back to Step 2, TR60+
Maximum Permissible Span (m)

2xA393
0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 - - - - - - - - - - - -

2xA393 Single 120 - - - - - - - - - - - -

2xA393 Single 130 - - - - - - - - - - - -

2xA393 Single 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 150 2.984 2.984 2.984 2.984 3.180 3.180 3.180 3.180 3.531 3.531 3.531 3.531

2xA393 Single 160 2.938 2.938 2.938 2.938 3.108 3.108 3.108 3.108 3.457 3.457 3.457 3.457

2xA393 Single 170 2.866 2.866 2.866 2.866 3.038 3.038 3.038 3.038 3.387 3.387 3.387 3.387

2xA393 Single 180 2.796 2.796 2.796 2.796 2.969 2.969 2.969 2.969 3.323 3.323 3.323 3.323

2xA393 Single 190 2.734 2.734 2.734 2.734 2.875 2.875 2.875 2.875 3.261 3.261 3.261 3.261

2xA393 Single 200 2.680 2.680 2.680 2.680 2.854 2.854 2.854 2.854 3.207 3.207 3.207 3.207

2xA393 Single 210 2.585 2.585 2.585 2.585 2.800 2.800 2.800 2.800 3.153 3.153 3.153 3.153

2xA393 Single 220 2.484 2.484 2.484 2.484 2.750 2.750 2.750 2.750 3.104 3.104 3.104 3.104

2xA393 Single 230 2.391 2.391 2.391 2.391 2.703 2.703 2.703 2.703 3.062 3.062 3.062 3.062

2xA393 Single 240 2.312 2.312 2.312 2.312 2.657 2.657 2.657 2.657 3.015 3.015 3.015 3.015

2xA393 Single 250 2.234 2.234 2.234 2.234 2.608 2.608 2.608 2.608 2.976 2.976 2.976 2.976

2xA393 Double 110 - - - - - - - - - - - -

2xA393 Double 120 - - - - - - - - - - - -

2xA393 Double 130 - - - - - - - - - - - -

2xA393 Double 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 150 3.197 3.197 3.197 3.046 3.511 3.511 3.391 3.069 3.961 3.961 3.438 3.116

2xA393 Double 160 3.102 3.102 3.102 3.100 3.408 3.408 3.408 3.125 3.912 3.912 3.500 3.172

2xA393 Double 170 3.015 3.015 3.015 3.015 3.315 3.315 3.315 3.188 3.862 3.862 3.562 3.234

2xA393 Double 180 2.934 2.934 2.934 2.934 3.226 3.226 3.226 3.226 3.763 3.763 3.625 3.296

2xA393 Double 190 2.858 2.858 2.858 2.858 3.145 3.145 3.145 3.145 3.672 3.672 3.672 3.375

2xA393 Double 200 2.788 2.788 2.788 2.788 3.069 3.069 3.069 3.069 3.585 3.585 3.585 3.492

2xA393 Double 210 2.722 2.722 2.722 2.722 2.998 2.998 2.998 2.998 3.503 3.503 3.503 3.503

2xA393 Double 220 2.662 2.662 2.662 2.662 2.930 2.930 2.930 2.930 3.426 3.426 3.426 3.426

2xA393 Double 230 2.604 2.604 2.604 2.604 2.868 2.868 2.868 2.868 3.354 3.354 3.354 3.354

2xA393 Double 240 2.548 2.548 2.548 2.548 2.808 2.808 2.808 2.808 3.288 3.288 3.288 3.288

2xA393 Double 250 2.496 2.496 2.496 2.496 2.753 2.753 2.753 2.753 3.222 3.222 3.222 3.222

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 49 of 72
THE WHITE BOOK
Contents

Floor deck profile


Deck profile
Initially added to our product range in 2002, the original TR80 has undergone further research and
development, evolving to TR80+. This 80mm deep trapezoidal profile is available in 0.9mm, 1.0mm and
TR80
1.2mm gauges in both S350 and S450 grade steel.

600 Cover Width


300
12
80

122

Options
• Reduced concrete volume compared to other decks available
• 140mm slab depth required to achieve a typical 1 hour fire rating
• Excellent un-propped span capability
• Trough stiffeners positioned to ensure central stud position, minimizing site checking required
• Soffit ‘Wedge Nut’ fixings available with load capacity of up to 1kN
• Acoustic Robust Solution – Refer Robust Details Handbook (www.robustdetails.com)
• Product options include HIGH
DURABILITY HD steel coating & TAB-Deck™ fibre concrete solution

Concrete volume and weight


Slab Depth Volume of Concrete Weight of Concrete (Normal Weight) Weight of Concrete (Lightweight)
mm m³/m² Wet kN/m² Dry kN/m² Wet kN/m² Dry kN/m²

140 0.096 2.40 2.31 1.93 1.84


150 0.106 2.65 2.55 2.13 2.03
160 0.116 2.90 2.79 2.33 2.22
170 0.126 3.15 3.03 2.53 2.41
180 0.136 3.40 3.27 2.73 2.60
200 0.156 3.90 3.75 3.14 2.98
225 0.181 4.53 4.35 3.64 3.46
250 0.206 5.15 4.95 4.14 3.94
Deflection – This table is based on concrete poured to a constant thickness and does not take account for deflection of the decking or supporting beams (as a guide, to account for the deflection of the
decking, a concrete volume of span/250 should be added to the figures indicated). Concrete Weight – These tables indicate concrete weight only and do not include the weight of decking or reinforcement.
Concrete weights are based on the concrete densities specified in Technical Design Table Notes, see page 4.

Profile properties
Nominal Design Grade Depth of Profile Weight of Profile Weight of Profile Height of Area of Steel Moment of Inertia
Thickness mm Thickness mm N/mm² mm kg/m² kN/m² Neutral Axis mm mm²/m cm4/m
0.9 0.86 350* 80 / 92** 11.33 0.111 42.3 1385 172.9
1.0 0.96 350* 80 / 92** 12.54 0.123 42.4 1539 192.3
1.2 1.16 350* 80 / 92** 15.06 0.148 42.5 1860 231.1
* This design guide is based on S350 grade steel, S450 grade is also available, download SMD Elements® Design software for calculations.
** Depth of profile indicates the nominal depth, ** represents depth including the top re-entrant.

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

50 of 72
THE WHITE BOOK
Back to Step 1

Step 2, TR80+ composite slab graph


Span and slab depth guidance graph
With proposed profile and gauge determined at step 1 on page 5, review the graph below to consider whether Load and Fire rating
govern the design. Construction stage governs (shown dashed) except where solid lines representing the different Load/Fire limits
are shown.

Note: This graph is based on A393 mesh. It may be possible to reduce mesh size by referencing
load/span tables during Step 3.

5.2

5.0 1hr Fire


1.5hr Fire
4.8 2hr Fire

4.6

4.4
Construction
Stage
4.2
TR80+ 1.2mm
4.0 5kN

3.8 5kN
Span Length (m)

kN
3.6 7.5
r
1h
TR80+ 1.0mm
r
3.4 1h N
10 k
3.2
kN
7.5 TR80+ 0.9mm
3.0
N
2.8 10k 7.5kN

2.6
Min for 1.5hr Fire

N
10k
Min for 2hr Fire

2.4

2.2

2.0
140 150 160 170 180 190 200 210 220 230 240 250
Slab Depth (mm)

1.0 Hour 1.5 Hour 2.0 Hour


Fire Rating Fire Rating Fire Rating
A142 A193 A252 A393 A142 A193 A252 A393 A142 A193 A252 A393
Pg.52 Pg.53 Pg54 Pg.55 Pg.58 Pg.59 Pg.60 Pg.61 Pg.64 Pg.65 Pg.66 Pg.67

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 51 of 72
1.0 Hr
A142BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 - - - - - - - - - - - -

A142 Single 120 - - - - - - - - - - - -

A142 Single 130 - - - - - - - - - - - -

A142 Single 140 3.883 3.883 2.922 2.633 4.180 4.180 3.000 2.703 4.430 4.430 3.149 2.839

A142 Single 150 3.781 3.781 3.054 2.757 4.069 4.069 3.133 2.835 4.343 4.343 3.296 2.976

A142 Single 160 - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - -

A142 Double 110 - - - - - - - - - - - -

A142 Double 120 - - - - - - - - - - - -

A142 Double 130 - - - - - - - - - - - -

A142 Double 140 4.284 3.930 2.922 2.633 4.549 4.031 3.000 2.703 5.170 4.234 3.149 2.839

A142 Double 150 4.137 4.077 3.054 2.757 4.521 4.180 3.133 2.835 5.019 4.391 3.296 2.976

A142 Double 160 - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

52 of 72
1.0 Hr
A193BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 - - - - - - - - - - - -

A193 Single 120 - - - - - - - - - - - -

A193 Single 130 - - - - - - - - - - - -

A193 Single 140 3.875 3.875 2.992 2.695 4.172 4.172 3.062 2.757 4.430 4.430 3.211 2.891

A193 Single 150 3.773 3.773 3.125 2.819 4.062 4.062 3.203 2.891 4.343 4.343 3.358 3.031

A193 Single 160 3.657 3.657 3.257 2.945 3.969 3.969 3.335 3.023 4.261 4.261 3.500 3.164

A193 Single 170 3.511 3.511 3.391 3.077 3.875 3.875 3.476 3.149 4.188 4.188 3.641 3.296

A193 Single 180 - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - -

A193 Double 110 - - - - - - - - - - - -

A193 Double 120 - - - - - - - - - - - -

A193 Double 130 - - - - - - - - - - - -

A193 Double 140 4.281 4.023 2.992 2.695 4.545 4.125 3.062 2.757 5.164 4.319 3.211 2.891

A193 Double 150 4.133 4.133 3.125 2.819 4.518 4.265 3.203 2.891 5.015 4.469 3.358 3.031

A193 Double 160 4.000 4.000 3.257 2.945 4.383 4.383 3.335 3.023 4.875 4.858 3.500 3.164

A193 Double 170 3.879 3.879 3.391 3.077 4.250 4.250 3.476 3.149 4.748 4.748 3.641 3.296

A193 Double 180 - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 53 of 72
1.0 Hr
A252BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 - - - - - - - - - - - -

A252 Single 120 - - - - - - - - - - - -

A252 Single 130 - - - - - - - - - - - -

A252 Single 140 ** ** ** ** ** ** ** ** ** ** ** **

A252 Single 150 3.773 3.773 3.195 2.883 4.062 4.062 3.265 2.953 4.339 4.339 3.414 3.085

A252 Single 160 3.657 3.657 3.319 3.007 3.961 3.961 3.399 3.077 4.257 4.257 3.554 3.211

A252 Single 170 3.508 3.508 3.453 3.126 3.866 3.866 3.827 3.203 4.188 4.188 3.688 3.343

A252 Single 180 3.494 3.494 3.494 3.257 3.781 3.781 3.781 3.335 4.120 4.120 4.120 3.484

A252 Single 190 3.374 3.374 3.374 3.374 3.703 3.703 3.703 3.453 4.058 4.058 4.058 3.843

A252 Single 200 3.219 3.219 3.219 3.219 3.625 3.625 3.625 3.625 4.000 4.000 4.000 3.969

A252 Single 210 - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - -

A252 Double 110 - - - - - - - - - - - -

A252 Double 120 - - - - - - - - - - - -

A252 Double 130 - - - - - - - - - - - -

A252 Double 140 ** ** ** ** ** ** ** ** ** ** ** **

A252 Double 150 4.129 4.129 3.195 2.883 4.514 4.358 3.265 2.953 5.011 4.843 3.414 3.085

A252 Double 160 3.996 3.996 3.319 3.007 4.376 4.376 3.399 3.077 4.872 4.872 3.554 3.211

A252 Double 170 3.875 3.875 3.453 3.126 4.246 4.246 3.531 3.203 4.744 4.744 3.688 3.343

A252 Double 180 3.761 3.761 3.585 3.257 4.125 4.125 3.672 3.335 4.653 4.653 3.835 3.484

A252 Double 190 3.657 3.657 3.657 3.383 4.013 4.013 3.796 3.453 4.638 4.638 3.969 3.608

A252 Double 200 3.562 3.562 3.562 3.461 3.907 3.907 3.883 3.538 4.534 4.534 4.054 3.695

A252 Double 210 - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

54 of 72
1.0 Hr
A393BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 - - - - - - - - - - - -

A393 Single 120 - - - - - - - - - - - -

A393 Single 130 - - - - - - - - - - - -

A393 Single 140 ** ** ** ** ** ** ** ** ** ** ** **

A393 Single 150 3.765 3.765 3.335 3.011 4.054 4.054 3.399 3.069 4.331 4.331 3.531 3.195

A393 Single 160 3.641 3.641 3.461 3.125 3.953 3.953 3.953 3.195 4.250 4.250 4.108 3.319

A393 Single 170 3.502 3.502 3.502 3.250 3.858 3.858 3.858 3.312 4.180 4.180 4.180 3.445

A393 Single 180 3.489 3.489 3.489 3.366 3.773 3.773 3.773 3.438 4.116 4.116 4.116 3.922

A393 Single 190 3.358 3.358 3.358 3.358 3.695 3.695 3.695 3.695 4.054 4.054 4.054 4.054

A393 Single 200 3.203 3.203 3.203 3.203 3.624 3.624 3.624 3.624 3.996 3.996 3.996 3.996

A393 Single 210 3.062 3.062 3.062 3.062 3.515 3.515 3.515 3.515 3.945 3.945 3.945 3.945

A393 Single 220 2.938 2.938 2.938 2.938 3.391 3.391 3.391 3.391 3.879 3.879 3.879 3.879

A393 Single 230 2.827 2.827 2.827 2.827 3.335 3.335 3.335 3.335 3.819 3.819 3.819 3.819

A393 Single 240 2.719 2.719 2.719 2.719 3.281 3.281 3.281 3.281 3.765 3.765 3.765 3.765

A393 Single 250 2.625 2.625 2.625 2.625 3.172 3.172 3.172 3.172 3.711 3.711 3.711 3.711

A393 Double 110 - - - - - - - - - - - -

A393 Double 120 - - - - - - - - - - - -

A393 Double 130 - - - - - - - - - - - -

A393 Double 140 ** ** ** ** ** ** ** ** ** ** ** **

A393 Double 150 4.120 4.120 3.335 3.011 4.506 4.506 3.399 3.069 5.000 5.000 3.531 3.195

A393 Double 160 3.988 3.988 3.461 3.125 4.366 4.366 3.531 3.195 4.862 4.862 3.672 3.319

A393 Double 170 3.866 3.866 3.585 3.250 4.238 4.238 3.657 3.312 4.734 4.734 3.804 3.445

A393 Double 180 3.753 3.753 3.711 3.366 4.116 4.116 3.781 3.438 4.646 4.646 3.938 3.577

A393 Double 190 3.649 3.649 3.649 3.484 4.003 4.003 3.907 3.554 4.631 4.631 4.062 3.695

A393 Double 200 3.554 3.554 3.554 3.554 3.901 3.901 3.901 3.664 4.527 4.527 4.172 3.804

A393 Double 210 3.465 3.465 3.465 3.465 3.804 3.804 3.804 3.773 4.418 4.418 4.296 3.922

A393 Double 220 3.379 3.379 3.379 3.379 3.713 3.713 3.713 3.713 4.315 4.315 4.315 4.038

A393 Double 230 3.300 3.300 3.300 3.300 3.629 3.629 3.629 3.629 4.219 4.219 4.219 4.157

A393 Double 240 3.172 3.172 3.172 3.172 3.548 3.548 3.548 3.548 4.129 4.129 4.129 4.129

A393 Double 250 3.046 3.046 3.046 3.046 3.472 3.472 3.472 3.472 4.042 4.042 4.042 4.042

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 55 of 72
1.0 Hr
BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
2xA252
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 - - - - - - - - - - - -

2xA252 Single 120 - - - - - - - - - - - -

2xA252 Single 130 - - - - - - - - - - - -

2xA252 Single 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 160 3.641 3.641 3.641 3.327 3.945 3.945 3.945 3.383 4.246 4.246 4.246 3.500

2xA252 Single 170 3.498 3.498 3.498 3.430 3.858 3.858 3.858 3.492 4.176 4.176 4.176 4.077

2xA252 Single 180 3.485 3.485 3.485 3.485 3.773 3.773 3.773 3.773 4.108 4.108 4.108 4.108

2xA252 Single 190 3.343 3.343 3.343 3.343 3.688 3.688 3.688 3.688 4.050 4.050 4.050 4.050

2xA252 Single 200 3.203 3.203 3.203 3.203 3.616 3.616 3.616 3.616 3.992 3.992 3.992 3.992

2xA252 Single 210 3.062 3.062 3.062 3.062 3.500 3.500 3.500 3.500 3.938 3.938 3.938 3.938

2xA252 Single 220 2.938 2.938 2.938 2.938 3.391 3.391 3.391 3.391 3.875 3.875 3.875 3.875

2xA252 Single 230 2.827 2.827 2.827 2.827 3.331 3.331 3.331 3.331 3.815 3.815 3.815 3.815

2xA252 Single 240 2.719 2.719 2.719 2.719 3.277 3.277 3.277 3.277 3.761 3.761 3.761 3.761

2xA252 Single 250 2.625 2.625 2.625 2.625 3.172 3.172 3.172 3.172 3.707 3.707 3.707 3.707

2xA252 Double 110 - - - - - - - - - - - -

2xA252 Double 120 - - - - - - - - - - - -

2xA252 Double 130 - - - - - - - - - - - -

2xA252 Double 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 160 3.980 3.980 3.680 3.327 4.358 4.358 3.742 3.383 4.854 4.854 3.866 3.500

2xA252 Double 170 3.858 3.858 3.781 3.430 4.230 4.230 3.850 3.492 4.726 4.726 3.984 3.608

2xA252 Double 180 3.746 3.746 3.746 3.538 4.108 4.108 3.961 3.600 4.641 4.641 4.100 3.726

2xA252 Double 190 3.645 3.645 3.645 3.633 3.998 3.998 3.998 3.695 4.626 4.626 4.203 3.827

2xA252 Double 200 3.548 3.548 3.548 3.548 3.895 3.895 3.895 3.788 4.519 4.519 4.304 3.922

2xA252 Double 210 3.459 3.459 3.459 3.459 3.798 3.798 3.798 3.798 4.410 4.410 4.399 4.015

2xA252 Double 220 3.375 3.375 3.375 3.375 3.707 3.707 3.707 3.707 4.308 4.308 4.308 4.124

2xA252 Double 230 3.296 3.296 3.296 3.296 3.624 3.624 3.624 3.624 4.213 4.213 4.213 4.213

2xA252 Double 240 3.172 3.172 3.172 3.172 3.542 3.542 3.542 3.542 4.124 4.124 4.124 4.124

2xA252 Double 250 3.031 3.031 3.031 3.031 3.469 3.469 3.469 3.469 4.038 4.038 4.038 4.038

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

56 of 72
1.0 Hr
BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

2xA393
0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 - - - - - - - - - - - -

2xA393 Single 120 - - - - - - - - - - - -

2xA393 Single 130 - - - - - - - - - - - -

2xA393 Single 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 160 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 170 3.487 3.487 3.487 3.487 3.843 3.843 3.843 3.843 4.164 4.164 4.164 4.164

2xA393 Single 180 3.474 3.474 3.474 3.474 3.757 3.757 3.757 3.757 4.100 4.100 4.100 4.100

2xA393 Single 190 3.327 3.327 3.327 3.327 3.680 3.680 3.680 3.680 4.038 4.038 4.038 4.038

2xA393 Single 200 3.172 3.172 3.172 3.172 3.608 3.608 3.608 3.608 3.984 3.984 3.984 3.984

2xA393 Single 210 3.046 3.046 3.046 3.046 3.484 3.484 3.484 3.484 3.930 3.930 3.930 3.930

2xA393 Single 220 2.922 2.922 2.922 2.922 3.379 3.379 3.379 3.379 3.866 3.866 3.866 3.866

2xA393 Single 230 2.812 2.812 2.812 2.812 3.319 3.319 3.319 3.319 3.804 3.804 3.804 3.804

2xA393 Single 240 2.703 2.703 2.703 2.703 3.265 3.265 3.265 3.265 3.750 3.750 3.750 3.750

2xA393 Single 250 2.608 2.608 2.608 2.608 3.157 3.157 3.157 3.157 3.699 3.699 3.699 3.699

2xA393 Double 110 - - - - - - - - - - - -

2xA393 Double 120 - - - - - - - - - - - -

2xA393 Double 130 - - - - - - - - - - - -

2xA393 Double 140 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 160 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 170 3.841 3.841 3.841 3.680 4.211 4.211 4.108 3.726 4.707 4.707 4.226 3.827

2xA393 Double 180 3.730 3.730 3.730 3.730 4.091 4.091 4.091 3.827 4.627 4.627 4.335 3.938

2xA393 Double 190 3.629 3.629 3.629 3.629 3.980 3.980 3.980 3.907 4.613 4.613 4.422 4.023

2xA393 Double 200 3.534 3.534 3.534 3.534 3.879 3.879 3.879 3.879 4.500 4.500 4.492 4.093

2xA393 Double 210 3.445 3.445 3.445 3.445 3.784 3.784 3.784 3.784 4.395 4.395 4.395 4.188

2xA393 Double 220 3.362 3.362 3.362 3.362 3.695 3.695 3.695 3.695 4.292 4.292 4.292 4.292

2xA393 Double 230 3.281 3.281 3.281 3.281 3.610 3.610 3.610 3.610 4.199 4.199 4.199 4.199

2xA393 Double 240 3.141 3.141 3.141 3.141 3.531 3.531 3.531 3.531 4.108 4.108 4.108 4.108

2xA393 Double 250 3.015 3.015 3.015 3.015 3.457 3.457 3.457 3.457 4.025 4.025 4.025 4.025

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 57 of 72
1.5 Hr
A142BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 - - - - - - - - - - - -

A142 Single 120 - - - - - - - - - - - -

A142 Single 130 - - - - - - - - - - - -

A142 Single 140 - - - - - - - - - - - -

A142 Single 150 3.781 3.350 2.519 2.277 4.069 3.438 2.585 2.335 4.343 3.608 2.719 2.453

A142 Single 160 - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - -

A142 Double 110 - - - - - - - - - - - -

A142 Double 120 - - - - - - - - - - - -

A142 Double 130 - - - - - - - - - - - -

A142 Double 140 - - - - - - - - - - - -

A142 Double 150 4.137 3.350 2.519 2.277 4.521 3.438 2.585 2.335 5.019 3.608 2.719 2.453

A142 Double 160 - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

58 of 72
1.5 Hr
A193BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 - - - - - - - - - - - -

A193 Single 120 - - - - - - - - - - - -

A193 Single 130 - - - - - - - - - - - -

A193 Single 140 - - - - - - - - - - - -

A193 Single 150 3.773 3.461 2.600 2.350 4.062 3.858 2.664 2.407 4.343 4.015 2.788 2.523

A193 Single 160 3.657 3.657 2.703 2.445 3.969 3.969 2.765 2.503 4.261 4.172 2.891 2.620

A193 Single 170 3.511 3.511 2.800 2.538 3.875 3.875 2.866 2.600 4.188 4.188 3.000 2.719

A193 Single 180 - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - -

A193 Double 110 - - - - - - - - - - - -

A193 Double 120 - - - - - - - - - - - -

A193 Double 130 - - - - - - - - - - - -

A193 Double 140 - - - - - - - - - - - -

A193 Double 150 4.133 3.461 2.600 2.350 4.518 3.546 2.664 2.407 5.015 3.711 2.788 2.523

A193 Double 160 4.000 3.562 2.703 2.445 4.383 3.649 2.765 2.503 4.875 3.812 2.891 2.620

A193 Double 170 3.879 3.664 2.800 2.538 4.250 3.750 2.866 2.600 4.748 3.922 3.000 2.719

A193 Double 180 - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 59 of 72
1.5 Hr
A252BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 - - - - - - - - - - - -

A252 Single 120 - - - - - - - - - - - -

A252 Single 130 - - - - - - - - - - - -

A252 Single 140 - - - - - - - - - - - -

A252 Single 150 3.773 3.773 2.688 2.430 4.062 4.062 2.750 2.484 4.339 4.312 2.866 2.593

A252 Single 160 3.657 3.657 2.781 2.519 3.961 3.961 2.843 2.577 4.257 4.257 2.969 2.688

A252 Single 170 3.508 3.508 2.876 2.612 3.866 3.866 2.945 2.672 4.188 4.188 3.069 2.788

A252 Single 180 3.494 3.494 2.980 2.711 3.781 3.781 3.046 2.769 4.120 4.120 3.180 2.891

A252 Single 190 3.374 3.374 3.085 2.812 3.703 3.703 3.149 2.874 4.058 4.058 3.288 2.992

A252 Single 200 3.219 3.219 3.195 2.914 3.625 3.625 3.265 2.976 4.000 4.000 3.399 3.100

A252 Single 210 - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - -

A252 Double 110 - - - - - - - - - - - -

A252 Double 120 - - - - - - - - - - - -

A252 Double 130 - - - - - - - - - - - -

A252 Double 140 - - - - - - - - - - - -

A252 Double 150 4.129 3.577 2.688 2.430 4.514 3.657 2.750 2.484 5.011 3.812 2.866 2.593

A252 Double 160 3.996 3.672 2.781 2.519 4.376 3.750 2.843 2.577 4.872 3.914 2.969 2.688

A252 Double 170 3.875 3.765 2.876 2.612 4.246 3.850 2.945 2.672 4.744 4.015 3.069 2.788

A252 Double 180 3.761 3.761 2.980 2.711 4.125 3.953 3.046 2.769 4.653 4.124 3.180 2.891

A252 Double 190 3.657 3.657 3.085 2.812 4.013 4.013 3.149 2.874 4.638 4.234 3.288 2.992

A252 Double 200 3.562 3.562 3.195 2.914 3.907 3.907 3.265 2.976 4.534 4.343 3.399 3.100

A252 Double 210 - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

60 of 72
1.5 Hr
A393BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 - - - - - - - - - - - -

A393 Single 120 - - - - - - - - - - - -

A393 Single 130 - - - - - - - - - - - -

A393 Single 140 - - - - - - - - - - - -

A393 Single 150 3.765 3.765 2.862 2.585 4.054 4.054 2.914 2.633 4.331 4.331 3.015 2.726

A393 Single 160 3.641 3.641 2.953 2.672 3.953 3.953 3.007 2.722 4.250 4.250 3.116 2.823

A393 Single 170 3.502 3.502 3.042 2.757 3.858 3.858 3.100 2.812 4.180 4.180 3.219 2.914

A393 Single 180 3.489 3.489 3.133 2.850 3.773 3.773 3.195 2.907 4.116 4.116 3.312 3.015

A393 Single 190 3.358 3.358 3.250 2.961 3.695 3.695 3.296 3.000 4.054 4.054 3.422 3.116

A393 Single 200 3.203 3.203 3.203 3.093 3.624 3.624 3.407 3.108 3.996 3.996 3.953 3.219

A393 Single 210 3.062 3.062 3.062 3.062 3.515 3.515 3.515 3.500 3.945 3.945 3.945 3.319

A393 Single 220 2.938 2.938 2.938 2.938 3.391 3.391 3.391 3.383 3.879 3.879 3.879 3.422

A393 Single 230 2.827 2.827 2.827 2.827 3.335 3.335 3.335 3.335 3.819 3.819 3.819 3.819

A393 Single 240 2.719 2.719 2.719 2.719 3.281 3.281 3.281 3.281 3.765 3.765 3.765 3.765

A393 Single 250 2.625 2.625 2.625 2.625 3.172 3.172 3.172 3.172 3.711 3.711 3.711 3.711

A393 Double 110 - - - - - - - - - - - -

A393 Double 120 - - - - - - - - - - - -

A393 Double 130 - - - - - - - - - - - -

A393 Double 140 - - - - - - - - - - - -

A393 Double 150 4.120 3.804 2.862 2.585 4.506 3.875 2.914 2.633 5.000 4.015 3.015 2.726

A393 Double 160 3.988 3.891 2.953 2.672 4.366 3.961 3.007 2.722 4.862 4.108 3.116 2.823

A393 Double 170 3.866 3.866 3.042 2.757 4.238 4.054 3.100 2.812 4.734 4.203 3.219 2.914

A393 Double 180 3.753 3.753 3.133 2.850 4.116 4.116 3.195 2.907 4.646 4.296 3.312 3.015

A393 Double 190 3.649 3.649 3.250 2.961 4.003 4.003 3.296 3.000 4.631 4.399 3.422 3.116

A393 Double 200 3.554 3.554 3.391 3.093 3.901 3.901 3.407 3.108 4.527 4.500 3.523 3.219

A393 Double 210 3.465 3.465 3.465 3.226 3.804 3.804 3.554 3.242 4.418 4.418 3.626 3.319

A393 Double 220 3.379 3.379 3.379 3.366 3.713 3.713 3.695 3.383 4.315 4.315 3.734 3.422

A393 Double 230 3.300 3.300 3.300 3.300 3.629 3.629 3.629 3.523 4.219 4.219 3.866 3.546

A393 Double 240 3.172 3.172 3.172 3.172 3.548 3.548 3.548 3.548 4.129 4.129 4.015 3.680

A393 Double 250 3.046 3.046 3.046 3.046 3.472 3.472 3.472 3.472 4.042 4.042 4.042 3.827

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 61 of 72
1.5 Hr
BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
2xA252
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 - - - - - - - - - - - -

2xA252 Single 120 - - - - - - - - - - - -

2xA252 Single 130 - - - - - - - - - - - -

2xA252 Single 140 - - - - - - - - - - - -

2xA252 Single 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Single 160 3.641 3.641 3.234 2.930 3.945 3.945 3.281 2.969 4.246 4.246 3.376 3.062

2xA252 Single 170 3.498 3.498 3.312 3.000 3.858 3.858 3.358 3.046 4.176 4.176 3.461 3.141

2xA252 Single 180 3.485 3.485 3.391 3.077 3.773 3.773 3.438 3.125 4.108 4.108 4.108 3.219

2xA252 Single 190 3.343 3.343 3.343 3.157 3.688 3.688 3.688 3.203 4.050 4.050 4.050 3.304

2xA252 Single 200 3.203 3.203 3.203 3.203 3.616 3.616 3.616 3.288 3.992 3.992 3.992 3.399

2xA252 Single 210 3.062 3.062 3.062 3.062 3.500 3.500 3.500 3.500 3.938 3.938 3.938 3.484

2xA252 Single 220 2.938 2.938 2.938 2.938 3.391 3.391 3.391 3.391 3.875 3.875 3.875 3.875

2xA252 Single 230 2.827 2.827 2.827 2.827 3.331 3.331 3.331 3.331 3.815 3.815 3.815 3.815

2xA252 Single 240 2.719 2.719 2.719 2.719 3.277 3.277 3.277 3.277 3.761 3.761 3.761 3.761

2xA252 Single 250 2.625 2.625 2.625 2.625 3.172 3.172 3.172 3.172 3.707 3.707 3.707 3.707

2xA252 Double 110 - - - - - - - - - - - -

2xA252 Double 120 - - - - - - - - - - - -

2xA252 Double 130 - - - - - - - - - - - -

2xA252 Double 140 - - - - - - - - - - - -

2xA252 Double 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA252 Double 160 3.980 3.980 3.234 2.930 4.358 4.327 3.281 2.969 4.854 4.453 3.376 3.062

2xA252 Double 170 3.858 3.858 3.312 3.000 4.230 4.230 3.358 3.046 4.726 4.523 3.461 3.141

2xA252 Double 180 3.746 3.746 3.391 3.077 4.108 4.108 3.438 3.125 4.641 4.593 3.546 3.219

2xA252 Double 190 3.645 3.645 3.469 3.157 3.998 3.998 3.523 3.203 4.626 4.626 3.633 3.304

2xA252 Double 200 3.548 3.548 3.548 3.242 3.895 3.895 3.608 3.288 4.519 4.519 3.719 3.399

2xA252 Double 210 3.459 3.459 3.459 3.343 3.798 3.798 3.695 3.375 4.410 4.410 3.812 3.484

2xA252 Double 220 3.375 3.375 3.375 3.375 3.707 3.707 3.707 3.492 4.308 4.308 3.899 3.569

2xA252 Double 230 3.296 3.296 3.296 3.296 3.624 3.624 3.624 3.624 4.213 4.213 4.000 3.664

2xA252 Double 240 3.172 3.172 3.172 3.172 3.542 3.542 3.542 3.542 4.124 4.124 4.124 3.796

2xA252 Double 250 3.031 3.031 3.031 3.031 3.469 3.469 3.469 3.469 4.038 4.038 4.038 3.930

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

62 of 72
1.5 Hr
BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

2xA393
0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 - - - - - - - - - - - -

2xA393 Single 120 - - - - - - - - - - - -

2xA393 Single 130 - - - - - - - - - - - -

2xA393 Single 140 - - - - - - - - - - - -

2xA393 Single 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 160 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 170 3.487 3.487 3.487 3.288 3.843 3.843 3.843 3.327 4.164 4.164 4.164 3.407

2xA393 Single 180 3.474 3.474 3.474 3.366 3.757 3.757 3.757 3.407 4.100 4.100 4.100 3.484

2xA393 Single 190 3.327 3.327 3.327 3.327 3.680 3.680 3.680 3.476 4.038 4.038 4.038 4.038

2xA393 Single 200 3.172 3.172 3.172 3.172 3.608 3.608 3.608 3.608 3.984 3.984 3.984 3.984

2xA393 Single 210 3.046 3.046 3.046 3.046 3.484 3.484 3.484 3.484 3.930 3.930 3.930 3.930

2xA393 Single 220 2.922 2.922 2.922 2.922 3.379 3.379 3.379 3.379 3.866 3.866 3.866 3.866

2xA393 Single 230 2.812 2.812 2.812 2.812 3.319 3.319 3.319 3.319 3.804 3.804 3.804 3.804

2xA393 Single 240 2.703 2.703 2.703 2.703 3.265 3.265 3.265 3.265 3.750 3.750 3.750 3.750

2xA393 Single 250 2.608 2.608 2.608 2.608 3.157 3.157 3.157 3.157 3.699 3.699 3.699 3.699

2xA393 Double 110 - - - - - - - - - - - -

2xA393 Double 120 - - - - - - - - - - - -

2xA393 Double 130 - - - - - - - - - - - -

2xA393 Double 140 - - - - - - - - - - - -

2xA393 Double 150 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 160 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 170 3.841 3.841 3.625 3.288 4.211 4.211 3.672 3.327 4.707 4.707 3.757 3.407

2xA393 Double 180 3.730 3.730 3.703 3.366 4.091 4.091 3.750 3.407 4.627 4.627 3.835 3.484

2xA393 Double 190 3.629 3.629 3.629 3.438 3.980 3.980 3.819 3.476 4.613 4.613 3.914 3.562

2xA393 Double 200 3.534 3.534 3.534 3.515 3.879 3.879 3.879 3.554 4.500 4.500 3.992 3.641

2xA393 Double 210 3.445 3.445 3.445 3.445 3.784 3.784 3.784 3.664 4.395 4.395 4.069 3.719

2xA393 Double 220 3.362 3.362 3.362 3.362 3.695 3.695 3.695 3.695 4.292 4.292 4.188 3.835

2xA393 Double 230 3.281 3.281 3.281 3.281 3.610 3.610 3.610 3.610 4.199 4.199 4.199 3.961

2xA393 Double 240 3.141 3.141 3.141 3.141 3.531 3.531 3.531 3.531 4.108 4.108 4.108 4.100

2xA393 Double 250 3.015 3.015 3.015 3.015 3.457 3.457 3.457 3.457 4.025 4.025 4.025 4.025

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 63 of 72
2.0 Hr
A142BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A142 Single 110 - - - - - - - - - - - -

A142 Single 120 - - - - - - - - - - - -

A142 Single 130 - - - - - - - - - - - -

A142 Single 140 - - - - - - - - - - - -

A142 Single 150 - - - - - - - - - - - -

A142 Single 160 - - - - - - - - - - - -

A142 Single 170 - - - - - - - - - - - -

A142 Single 180 - - - - - - - - - - - -

A142 Single 190 - - - - - - - - - - - -

A142 Single 200 - - - - - - - - - - - -

A142 Single 210 - - - - - - - - - - - -

A142 Single 220 - - - - - - - - - - - -

A142 Single 230 - - - - - - - - - - - -

A142 Single 240 - - - - - - - - - - - -

A142 Single 250 - - - - - - - - - - - -

A142 Double 110 - - - - - - - - - - - -

A142 Double 120 - - - - - - - - - - - -

A142 Double 130 - - - - - - - - - - - -

A142 Double 140 - - - - - - - - - - - -

A142 Double 150 - - - - - - - - - - - -

A142 Double 160 - - - - - - - - - - - -

A142 Double 170 - - - - - - - - - - - -

A142 Double 180 - - - - - - - - - - - -

A142 Double 190 - - - - - - - - - - - -

A142 Double 200 - - - - - - - - - - - -

A142 Double 210 - - - - - - - - - - - -

A142 Double 220 - - - - - - - - - - - -

A142 Double 230 - - - - - - - - - - - -

A142 Double 240 - - - - - - - - - - - -

A142 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

64 of 72
2.0 Hr
A193BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A193 Single 110 - - - - - - - - - - - -

A193 Single 120 - - - - - - - - - - - -

A193 Single 130 - - - - - - - - - - - -

A193 Single 140 - - - - - - - - - - - -

A193 Single 150 - - - - - - - - - - - -

A193 Single 160 3.657 3.172 2.407 2.180 3.969 3.234 2.457 2.226 4.261 3.366 2.562 2.319

A193 Single 170 3.511 3.250 2.492 2.261 3.875 3.319 2.542 2.308 4.188 3.453 2.645 2.399

A193 Single 180 - - - - - - - - - - - -

A193 Single 190 - - - - - - - - - - - -

A193 Single 200 - - - - - - - - - - - -

A193 Single 210 - - - - - - - - - - - -

A193 Single 220 - - - - - - - - - - - -

A193 Single 230 - - - - - - - - - - - -

A193 Single 240 - - - - - - - - - - - -

A193 Single 250 - - - - - - - - - - - -

A193 Double 110 - - - - - - - - - - - -

A193 Double 120 - - - - - - - - - - - -

A193 Double 130 - - - - - - - - - - - -

A193 Double 140 - - - - - - - - - - - -

A193 Double 150 - - - - - - - - - - - -

A193 Double 160 4.000 3.172 2.407 2.180 4.358 3.234 2.457 2.226 4.804 3.366 2.562 2.319

A193 Double 170 3.879 3.250 2.492 2.261 4.250 3.319 2.542 2.308 4.562 3.453 2.645 2.399

A193 Double 180 - - - - - - - - - - - -

A193 Double 190 - - - - - - - - - - - -

A193 Double 200 - - - - - - - - - - - -

A193 Double 210 - - - - - - - - - - - -

A193 Double 220 - - - - - - - - - - - -

A193 Double 230 - - - - - - - - - - - -

A193 Double 240 - - - - - - - - - - - -

A193 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 65 of 72
2.0 Hr
A252BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A252 Single 110 - - - - - - - - - - - -

A252 Single 120 - - - - - - - - - - - -

A252 Single 130 - - - - - - - - - - - -

A252 Single 140 - - - - - - - - - - - -

A252 Single 150 - - - - - - - - - - - -

A252 Single 160 3.657 3.296 2.503 2.269 3.961 3.358 2.554 2.312 4.257 3.484 2.645 2.399

A252 Single 170 3.508 3.375 2.585 2.343 3.866 3.438 2.633 2.387 4.188 3.562 2.726 2.476

A252 Single 180 3.494 3.453 2.668 2.426 3.781 3.781 2.719 2.469 4.120 4.077 2.819 2.562

A252 Single 190 3.374 3.374 2.757 2.515 3.703 3.703 2.808 2.558 4.058 4.058 2.914 2.653

A252 Single 200 3.219 3.219 2.883 2.633 3.625 3.625 2.899 2.649 4.000 4.000 3.007 2.746

A252 Single 210 - - - - - - - - - - - -

A252 Single 220 - - - - - - - - - - - -

A252 Single 230 - - - - - - - - - - - -

A252 Single 240 - - - - - - - - - - - -

A252 Single 250 - - - - - - - - - - - -

A252 Double 110 - - - - - - - - - - - -

A252 Double 120 - - - - - - - - - - - -

A252 Double 130 - - - - - - - - - - - -

A252 Double 140 - - - - - - - - - - - -

A252 Double 150 - - - - - - - - - - - -

A252 Double 160 3.996 3.296 2.503 2.269 4.376 3.358 2.554 2.312 4.872 3.484 2.645 2.399

A252 Double 170 3.875 3.375 2.585 2.343 4.246 3.438 2.633 2.387 4.744 3.562 2.726 2.476

A252 Double 180 3.761 3.453 2.668 2.426 4.125 3.523 2.719 2.469 4.653 3.649 2.819 2.562

A252 Double 190 3.657 3.546 2.757 2.515 4.013 3.608 2.808 2.558 4.638 3.742 2.914 2.653

A252 Double 200 3.562 3.562 2.883 2.633 3.907 3.703 2.899 2.649 4.534 3.843 3.007 2.746

A252 Double 210 - - - - - - - - - - - -

A252 Double 220 - - - - - - - - - - - -

A252 Double 230 - - - - - - - - - - - -

A252 Double 240 - - - - - - - - - - - -

A252 Double 250 - - - - - - - - - - - -

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

66 of 72
2.0 Hr
A393BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

A393 Single 110 - - - - - - - - - - - -

A393 Single 120 - - - - - - - - - - - -

A393 Single 130 - - - - - - - - - - - -

A393 Single 140 - - - - - - - - - - - -

A393 Single 150 - - - - - - - - - - - -

A393 Single 160 3.641 3.641 2.688 2.438 3.953 3.953 2.734 2.476 4.250 4.250 2.819 2.554

A393 Single 170 3.502 3.502 2.773 2.515 3.858 3.858 2.812 2.550 4.180 4.180 2.899 2.633

A393 Single 180 3.489 3.489 2.891 2.626 3.773 3.773 2.914 2.649 4.116 4.116 2.984 2.711

A393 Single 190 3.358 3.358 3.015 2.750 3.695 3.695 3.038 2.765 4.054 4.054 3.085 2.804

A393 Single 200 3.203 3.203 3.157 2.875 3.624 3.624 3.172 2.891 3.996 3.996 3.203 2.926

A393 Single 210 3.062 3.062 3.062 3.015 3.515 3.515 3.312 3.027 3.945 3.945 3.335 3.054

A393 Single 220 2.938 2.938 2.938 2.938 3.391 3.391 3.391 3.164 3.879 3.879 3.476 3.188

A393 Single 230 2.827 2.827 2.827 2.827 3.335 3.335 3.335 3.304 3.819 3.819 3.819 3.319

A393 Single 240 2.719 2.719 2.719 2.719 3.281 3.281 3.281 3.281 3.765 3.765 3.765 3.515

A393 Single 250 2.625 2.625 2.625 2.625 3.172 3.172 3.172 3.172 3.711 3.711 3.711 3.672

A393 Double 110 - - - - - - - - - - - -

A393 Double 120 - - - - - - - - - - - -

A393 Double 130 - - - - - - - - - - - -

A393 Double 140 - - - - - - - - - - - -

A393 Double 150 - - - - - - - - - - - -

A393 Double 160 3.988 3.546 2.688 2.438 4.366 3.593 2.734 2.476 4.862 3.703 2.819 2.554

A393 Double 170 3.866 3.625 2.773 2.515 4.238 3.672 2.812 2.550 4.734 3.781 2.899 2.633

A393 Double 180 3.753 3.750 2.891 2.626 4.116 3.781 2.914 2.649 4.646 3.866 2.984 2.711

A393 Double 190 3.649 3.649 3.015 2.750 4.003 3.907 3.038 2.765 4.631 3.961 3.085 2.804

A393 Double 200 3.554 3.554 3.157 2.875 3.901 3.901 3.172 2.891 4.527 4.093 3.203 2.926

A393 Double 210 3.465 3.465 3.296 3.015 3.804 3.804 3.312 3.027 4.418 4.234 3.335 3.054

A393 Double 220 3.379 3.379 3.379 3.157 3.713 3.713 3.453 3.164 4.315 4.315 3.476 3.188

A393 Double 230 3.300 3.300 3.300 3.300 3.629 3.629 3.608 3.304 4.219 4.219 3.625 3.319

A393 Double 240 3.172 3.172 3.172 3.172 3.548 3.548 3.548 3.453 4.129 4.129 3.773 3.461

A393 Double 250 3.046 3.046 3.046 3.046 3.472 3.472 3.472 3.472 4.042 4.042 3.922 3.608

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 67 of 72
2.0 Hr
BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)
2xA252
THE WHITE

0.9mm Gauge 1.0mm Gauge 1.2mm Gauge


Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA252 Single 110 - - - - - - - - - - - -

2xA252 Single 120 - - - - - - - - - - - -

2xA252 Single 130 - - - - - - - - - - - -

2xA252 Single 140 - - - - - - - - - - - -

2xA252 Single 150 - - - - - - - - - - - -

2xA252 Single 160 3.641 3.641 2.953 2.672 3.945 3.945 2.988 2.703 4.246 4.246 3.062 2.773

2xA252 Single 170 3.498 3.498 3.069 2.788 3.858 3.858 3.108 2.819 4.176 4.176 3.180 2.891

2xA252 Single 180 3.485 3.485 3.133 2.850 3.773 3.773 3.172 2.883 4.108 4.108 3.250 2.957

2xA252 Single 190 3.343 3.343 3.203 2.914 3.688 3.688 3.242 2.953 4.050 4.050 3.327 3.027

2xA252 Single 200 3.203 3.203 3.203 3.007 3.616 3.616 3.319 3.031 3.992 3.992 3.399 3.100

2xA252 Single 210 3.062 3.062 3.062 3.062 3.500 3.500 3.500 3.141 3.938 3.938 3.484 3.180

2xA252 Single 220 2.938 2.938 2.938 2.938 3.391 3.391 3.391 3.265 3.875 3.875 3.875 3.296

2xA252 Single 230 2.827 2.827 2.827 2.827 3.331 3.331 3.331 3.331 3.815 3.815 3.815 3.422

2xA252 Single 240 2.719 2.719 2.719 2.719 3.277 3.277 3.277 3.277 3.761 3.761 3.761 3.761

2xA252 Single 250 2.625 2.625 2.625 2.625 3.172 3.172 3.172 3.172 3.707 3.707 3.707 3.707

2xA252 Double 110 - - - - - - - - - - - -

2xA252 Double 120 - - - - - - - - - - - -

2xA252 Double 130 - - - - - - - - - - - -

2xA252 Double 140 - - - - - - - - - - - -

2xA252 Double 150 - - - - - - - - - - - -

2xA252 Double 160 3.980 3.891 2.953 2.672 4.358 3.938 2.988 2.703 4.854 4.031 3.062 2.773

2xA252 Double 170 3.858 3.858 3.069 2.788 4.230 4.062 3.108 2.819 4.726 4.157 3.180 2.891

2xA252 Double 180 3.746 3.746 3.133 2.850 4.108 4.108 3.172 2.883 4.641 4.211 3.250 2.957

2xA252 Double 190 3.645 3.645 3.203 2.914 3.998 3.998 3.242 2.953 4.626 4.273 3.327 3.027

2xA252 Double 200 3.548 3.548 3.296 3.007 3.895 3.895 3.319 3.031 4.519 4.335 3.399 3.100

2xA252 Double 210 3.459 3.459 3.422 3.125 3.798 3.798 3.438 3.141 4.410 4.410 3.484 3.180

2xA252 Double 220 3.375 3.375 3.375 3.250 3.707 3.707 3.569 3.265 4.308 4.308 3.608 3.296

2xA252 Double 230 3.296 3.296 3.296 3.296 3.624 3.624 3.624 3.391 4.213 4.213 3.734 3.422

2xA252 Double 240 3.172 3.172 3.172 3.172 3.542 3.542 3.542 3.531 4.124 4.124 3.875 3.554

2xA252 Double 250 3.031 3.031 3.031 3.031 3.469 3.469 3.469 3.469 4.038 4.038 4.015 3.688

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

68 of 72
2.0 Hr
BOOK
Back to Step 2, TR80+
Maximum Permissible Span (m)

2xA393
0.9mm Gauge 1.0mm Gauge 1.2mm Gauge

THE WHITE
Deck Slab
Mesh FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN FW 5.0kN 7.5kN 10.0kN
Span Depth

2xA393 Single 110 - - - - - - - - - - - -

2xA393 Single 120 - - - - - - - - - - - -

2xA393 Single 130 - - - - - - - - - - - -

2xA393 Single 140 - - - - - - - - - - - -

2xA393 Single 150 - - - - - - - - - - - -

2xA393 Single 160 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Single 170 3.487 3.487 3.399 3.085 3.843 3.843 3.430 3.108 4.164 4.164 3.492 3.164

2xA393 Single 180 3.474 3.474 3.472 3.157 3.757 3.757 3.757 3.188 4.100 4.100 4.100 3.250

2xA393 Single 190 3.327 3.327 3.327 3.219 3.680 3.680 3.680 3.250 4.038 4.038 4.038 3.312

2xA393 Single 200 3.172 3.172 3.172 3.172 3.608 3.608 3.608 3.319 3.984 3.984 3.984 3.375

2xA393 Single 210 3.046 3.046 3.046 3.046 3.484 3.484 3.484 3.430 3.930 3.930 3.930 3.476

2xA393 Single 220 2.922 2.922 2.922 2.922 3.379 3.379 3.379 3.379 3.866 3.866 3.866 3.866

2xA393 Single 230 2.812 2.812 2.812 2.812 3.319 3.319 3.319 3.319 3.804 3.804 3.804 3.804

2xA393 Single 240 2.703 2.703 2.703 2.703 3.265 3.265 3.265 3.265 3.750 3.750 3.750 3.750

2xA393 Single 250 2.608 2.608 2.608 2.608 3.157 3.157 3.157 3.157 3.699 3.699 3.699 3.699

2xA393 Double 110 - - - - - - - - - - - -

2xA393 Double 120 - - - - - - - - - - - -

2xA393 Double 130 - - - - - - - - - - - -

2xA393 Double 140 - - - - - - - - - - - -

2xA393 Double 150 - - - - - - - - - - - -

2xA393 Double 160 ** ** ** ** ** ** ** ** ** ** ** **

2xA393 Double 170 3.841 3.841 3.399 3.085 4.211 4.211 3.430 3.108 4.707 4.554 3.492 3.164

2xA393 Double 180 3.730 3.730 3.476 3.157 4.091 4.091 3.507 3.188 4.627 4.625 3.569 3.250

2xA393 Double 190 3.629 3.629 3.538 3.219 3.980 3.980 3.569 3.250 4.613 4.613 3.641 3.312

2xA393 Double 200 3.534 3.534 3.534 3.304 3.879 3.879 3.641 3.319 4.500 4.500 3.703 3.375

2xA393 Double 210 3.445 3.445 3.445 3.414 3.784 3.784 3.757 3.430 4.395 4.395 3.796 3.476

2xA393 Double 220 3.362 3.362 3.362 3.362 3.695 3.695 3.695 3.554 4.292 4.292 3.922 3.593

2xA393 Double 230 3.281 3.281 3.281 3.281 3.610 3.610 3.610 3.610 4.199 4.199 4.046 3.711

2xA393 Double 240 3.141 3.141 3.141 3.141 3.531 3.531 3.531 3.531 4.108 4.108 4.108 3.843

2xA393 Double 250 3.015 3.015 3.015 3.015 3.457 3.457 3.457 3.457 4.025 4.025 4.025 3.984

For design notes relating to these tables, refer page 4. Where "-" is shown, mesh size or fire insulation thickness is insufficient.

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 69 of 72
El
Elements®
Design Software

El
Design
Tool
Elements® Design Software

Create and design floor slab and


roof deck calculations
The latest version of SMD Elements® with additional features allowing
calculations to be created for all SMD’s floor and roof deck profiles.

Floor and Roof Deck Calculation Tutorial's


A series of helpful tutorial's have been created which takes you on a step-
YouTube by-step process through each section of the software and explains how to
create a floor deck calculation using SMD floor deck profiles.

To download, please visit


www.smdltd.co.uk

Connect with us
THE WHITE BOOK
Notes

Floor Deck Design Guide and Tables


SMD-TEC-528 V2 71 of 72
SMD
Structural Floor and Roof Solutions

www.smdltd.co.uk

UK Tel: +44 (0) 1202 718898


UK Email: contactus@smdltd.co.uk

UK Head Office
The Outlook Ling Road Tower Park Poole Dorset BH12 4PY UK

UK Midlands Logistics Centre


Units 1+2 Nunn Brook Rise County Estate Huthwaite Nottinghamshire NG17 2PD

UK Scottish Logistics Centre


12 Palacecraig Street Coatbridge North Lanarkshire ML5 4RY

International Offices
United Arab Emirates – Dubai Email: uae.export@smdltd.co.uk
India – Mumbai Email: india@smdltd.co.uk

© SMD is a trading name of Structural Metal Decks Limited. Copyright 2018. Liable to change without notice. Version 2.0 - August 2018

Vous aimerez peut-être aussi