Maa-6.

3261
Precise Levelling: differential &
digital

Dr. ANDREI, Constantin-Octavian


octavian.andrei@aalto.fi
Syllabus: tentative lectures (period II)

Week Topic Description Text book


44 TS Summary
45 DL Digital levelling: background, 2.1-2.8
instrumentation, field techniques and
procedures
46 DL Precise levelling computations 2.14-2.17
47 TLS Terrestrial Laser Scanning: principles, work- Schoefield
flow in geodetic engineering, applications 14.9 +
handouts
48 TLS TLS raw data processing
49 TLS Summary
50 Revision

Maa-6.3261 2
octavian.andrei@aalto.fi
AaltoENG
Reference material

•  Course book (Kanavagh)


–  Sect 2.1-2.8

•  Alternative or complementary (Schofield)


–  Sect 3.5, 3.7-3.9, 3.14

Any other Surveying textbook containing a


Levelling chapter should be suficient!

Maa-6.3261 3
octavian.andrei@aalto.fi
AaltoENG
After this part you will be able

•  To explain the concepts of differential and digital


levelling

•  To carry out a digital levelling procedure

Maa-6.3261 4
octavian.andrei@aalto.fi
AaltoENG
Differential levelling

•  Background
•  Instrumentation
•  Principle
•  Check & Adjust
•  Methods of booking

Maa-6.3261 5
octavian.andrei@aalto.fi
AaltoENG
Levelling concepts

•  Elevation
•  Datum, Mean sea level
•  Vertical line
•  Level line
•  Horizontal line

Maa-6.3261 6
octavian.andrei@aalto.fi
AaltoENG
Levelling process

RR@A = 6.27
RR@B = 4.69

ΔHAB = 1.58

H@A = 61.27
H@B = 62.85

Can you see any potential problem?


Maa-6.3261 7
octavian.andrei@aalto.fi
AaltoENG
Effects of Curvature

•  Elevation refers to level line


•  Line-of-sigh is almost horizontal
line

•  All RRs contain an error c over Mean radius of Earth


a distance d R= 6370 km

•  The curvature (divergence)


–  0.8 mm for 100 m
–  7.1 mm for 300 m c = D2/2R or c = 0.0785 D2

with c in meters and D in kilometers

Maa-6.3261 8
octavian.andrei@aalto.fi
AaltoENG
Effects of Curvature and Refraction

•  Refraction (r) is affected by


atmospheric pressure,
temperature, and geographic
location

•  The effect is to bend the line of


sight down

•  One-seventh of the curvature


error
Combined effect: (c – r) = 0.0673 D2
–  r = 0.14 c
Example: D = 122 m => (c – r) = 1 mm

Maa-6.3261 9
octavian.andrei@aalto.fi
AaltoENG
Types of Surveying Levels

Automatic level Digital level

Tilting level Dumpy level


Rotary laser level

Maa-6.3261 10
octavian.andrei@aalto.fi
AaltoENG
Leveling Rods

•  Rod, staff, stadia

•  Wood, metal, or fiberglass


•  One- or multiple-piece rods
–  Folding
–  Telescopic

•  Graduated
•  Invar strip
•  Bar-code

Maa-6.3261 11
octavian.andrei@aalto.fi
AaltoENG
Rod Reading examples

Maa-6.3261 12
octavian.andrei@aalto.fi
AaltoENG
Definitions for Differential Levelling

•  BM: bench mark, permanent point with published known elevation

•  TBM: semipermanent point with unpublished known elevation

•  TP: point used temporary to transfer an elevation

•  BS: rod reading to establish the elevation of the instrument line of sight

•  HI: elevation of the line of sight

•  FS: rod reading taken on a TP, BM, TBM

•  IS: rod reading taken at any other point where elevation is required

Maa-6.3261 13
octavian.andrei@aalto.fi
AaltoENG
BM, TBM, TP

Bronze disk or plug set

Benchmark
Turning  plate  (Turtle)

Maa-6.3261 14
Flange bolt octavian.andrei@aalto.fi
AaltoENG Turning pin
Differential levelling procedure
Elevation @BM.A = 410.26
RR @BM.A = +4.71 (BS)
HI (line-of-sight) = 414.97 (HI)
RR @TBM.B = -2.80 (FS)
Elevation @TBM.A = 412.17

Direction of survey

New elevation = Existing elevation + BS – FS (IS)

Maa-6.3261 15
octavian.andrei@aalto.fi
AaltoENG
Differential levelling: multiple setups

Original elevation + ΣBS – ΣFS = Final elevation

Maa-6.3261 16
octavian.andrei@aalto.fi
AaltoENG
Collimation check

Two-peg test

Maa-6.3261 17
octavian.andrei@aalto.fi
AaltoENG
Collimation Check

•  Allow instrument and rods to acclimate prior to performing


the collimation and/or leveling (allow equipment to adjust
to the working environment for 10 minutes or more)

•  Perform Collimation Check on level ground at the work


site in the work environment (slope less than 2%)

•  Perform a Collimation Check at the beginning of every day


that geodetic leveling is performed or when the level is
jarred or any time there is a question about the instrument

Maa-6.3261 18
octavian.andrei@aalto.fi
AaltoENG
Collimation check (continued)

•  Perform a Collimation Check whenever the ambient


temperature changes more than 10 degrees Celsius
during the course of leveling during the day
•  Remove parallax and sharply focus the instrument and
ensure all circular levels are in adjustment
•  Apply collimation to all future measurements (also note
in digital data files that this correction has been applied
to all measurements)
•  Record collimation (arc-seconds) on Backup Recording
Sheet

Maa-6.3261 19
octavian.andrei@aalto.fi
AaltoENG
Collimation Check - Kukkamaki Method
AxBx
Rod A Rod B

Instrument Instrument
Position 1 Position 2

10 m 10 m 20 m
Set up 2 staves (A, B) roughly 20 m apart. First measure these staves from instrument
station (1) located midway on the connecting line between the two staves. Then repeat
the measurement from instrument station (2) which is located on the elongation of the
two staff stations approx. 20 m outside the defined distance.
Maa-6.3261 20
octavian.andrei@aalto.fi
AaltoENG
Collimation Check - Japanese Method
Rod B
Rod A A x Bx
Instrument Instrument
Position 1 Position 2

1/2 L 1/2 L 1/10 L

This method is largely identical with the Kukkamaki method. With this method, however,
the distance between the staves should be about 30 m with station (2) being about 3 m
behind staff A.

Maa-6.3261 21
octavian.andrei@aalto.fi
AaltoENG
Collimation Check – Förstner Method
AxxB
Rod A Rod B

Instrument Instrument
Position 1 Position 2

1/3 1/3 1/3

15 m 15 m 15 m

Set up two staves (A,B) roughly 45 m apart. Divide this distance into three and
define 2 instrument stations (1,2) about 15 m away from the staves on the
connecting line between them. Measure both staves from each of these stations.

Maa-6.3261 22
octavian.andrei@aalto.fi
AaltoENG
Collimation Check – Näbauer Method
Rod A
x A B x Rod B

Instrument Instrument
Position 1 Position 2

1/3 1/3 1/3

15 m 15 m 15 m

Define a distance of approx. 45 m length and divide it roughly into three. Create an
instrument station (1,2) at either end and set up a staff at each point marking one third of
the connecting line (A,B). Measure both staves from each of the instrument stations.

Maa-6.3261 23
octavian.andrei@aalto.fi
AaltoENG
Maa-6.3261 24
octavian.andrei@aalto.fi
AaltoENG
Methods of booking

1.  Rise-and-fall
2.  Height of collimation
3.  Inverted staff

Maa-6.3261 25
octavian.andrei@aalto.fi
AaltoENG
Rise-and-fall method

Σ BS - Σ FS = sum of rises − sum of falls = last reduced level − first reduced level

Maa-6.3261 26
octavian.andrei@aalto.fi
AaltoENG
Height of collimation method

Σ RL (except the first) = Σ (HPC x the number of IS or FS taken from it) − Σ (IS + FS)

Maa-6.3261 27
octavian.andrei@aalto.fi
AaltoENG
Inverted staff

inverted sights are treated as negative quantities

Maa-6.3261 28
octavian.andrei@aalto.fi
AaltoENG
Precise levelling rules (few)

•  Never Setup on Asphalt


•  Double Run Everything
•  Never Read Below 0.5 Meter on Rod
•  All Three Crosshairs Must be on Invar
•  Same Rod on Starting and Ending BM
•  Use Hammer and Pins as Turning Points
•  Always Keep a Hand on Rod when Setup
•  Keep Setup Imbalance at a Minimum

Maa-6.3261 29
octavian.andrei@aalto.fi
AaltoENG
Applications

•  Benchmark levelling
–  Vertical control surveys
•  Profile and Cross-section levelling
–  Road, sewer pipeline, channel, etc
•  Reciprocal levelling
–  River or valley crossing
•  Contouring

Maa-6.3261 30
octavian.andrei@aalto.fi
AaltoENG
Digital levelling

•  Instrumentation
•  Measuring
–  Principle, procedure, processing
•  Factors affecting the measuring procedure
•  Operating features
•  Advantages

Maa-6.3261 31
octavian.andrei@aalto.fi
AaltoENG
Digital levelling system

•  Bar code rod

•  Digital level
–  Levelling instrument
–  CCD (couple charge
device) camera

Maa-6.3261 32
octavian.andrei@aalto.fi
AaltoENG
DL: Principle

•  The image of the whole bar code rod is stored in the


instrument as reference
•  Digital level sees only a certain sector of the bar code rod
•  Sectors length depends on sighting distance and optics of
the instrument
•  CCD- camera grabs a gray value image for rod sector
•  DL recognize its position with the digital image processing
•  DL determines the height reading and horizontal distance

Maa-6.3261 33
octavian.andrei@aalto.fi
AaltoENG
DL: Procedure

•  Level
•  Point
•  Focus
•  Trigger

•  Few seconds

•  Coarse correlation
•  Fine correlation

Maa-6.3261 34
octavian.andrei@aalto.fi
AaltoENG
DL: Processing

Maa-6.3261 35
octavian.andrei@aalto.fi
AaltoENG
Factors affecting the measuring process

•  Pointing and focusing

•  Vibrations and heat shimmer

•  Illumination

•  Staff coverage

•  Collimation

•  Physical damage
See more on pg.49-50 from the DNA03 user manual

Maa-6.3261 36
octavian.andrei@aalto.fi
AaltoENG
Corrections @ the instrument

•  Balance backsights/foresights •  Use mean/median mode for


•  Calibrate for collimation error VIBRATION
•  Keep earth curvature correction •  Hold tripod to dampen
ON VIBRATION
•  Setup on stable ground •  Avoid bridges; place rod on
bridge instead
•  Measure 0.5 m above the
ground when HOT
•  Shorten the distance to rod
when HOT

Maa-6.3261 37
octavian.andrei@aalto.fi
AaltoENG
Corrections @ the rod

•  Check and calibrate bubble


level
•  Brace rod firmly
•  Leap from two rods
•  Designate one rod for turning
points only
•  Clean bottom of the rod
•  Choose a solid, prominent
turning point
•  Clearly mark the turning point

Maa-6.3261 38
octavian.andrei@aalto.fi
AaltoENG
Advantages

•  Increase productivity (about 50% in time)


•  Eliminate the field booking mistakes
•  Preprogrammed functions

•  But any human mistake may prove significant

Maa-6.3261 39
octavian.andrei@aalto.fi
AaltoENG
Level unit

•  One Observer (Instrument •  One Pacer to Help with Setups


Person)* •  Computer to Download and
•  Two Rod People* Process Data*
•  One or Two Vehicles
–  One capable of transporting
equipment – rods*
–  Drop one vehicle at end of
day’s work
•  Safety People if Necessary
–  Warning Person to drive
behind crew

* Required

Maa-6.3261 40
octavian.andrei@aalto.fi
AaltoENG
Levelling tips

•  Current line-of-sight error OK


•  Earth curvature correction ON/OFF
•  Which measurement mode to use

•  Setup in relatively convenient location


•  Spread the legs to increase stability
•  Check the clarity of the cross-hairs
•  Place the device midway
•  Close the leveling line

Maa-6.3261 41
octavian.andrei@aalto.fi
AaltoENG
Example: Levelling at the Olkiluoto

http://www.fgi.fi/fgi/themes/detecting-crustal-deformation

Maa-6.3261 42
octavian.andrei@aalto.fi
AaltoENG
Please be Safe!

Maa-6.3261 43
octavian.andrei@aalto.fi
AaltoENG
Resources

Maa-6.3261 44
octavian.andrei@aalto.fi
AaltoENG
TODO list

Maa-6.3261 45
octavian.andrei@aalto.fi
AaltoENG
Leica DNA03

Maa-6.3261 46
octavian.andrei@aalto.fi
AaltoENG
Operating features: Leica DNA03

•  Program version •  Sight distance range 1.8 m to


•  Accuracy 100 m
–  Invar staff: 0.3 mm / km double •  Measuring time (single): 3 sec
–  Standard staff: 1.0 mm •  Operation temperature:
–  Optical: 2.0 mm –  -20°C +50°C
–  Distance: 5 mm / 10 m
•  Opening angle: 2 deg •  6000 measurements (or 1650
stations BF)
•  Magnetically damped •  Dimensions
pendulum compensator –  158 (H) x 240 (W) x 210 (L)
–  2.85 kg

Maa-6.3261 47
octavian.andrei@aalto.fi
AaltoENG
Leica DNA03 functions

•  Functions (FNC) •  Measurement programs


1.  Test measurement –  Measure & Record
2.  View measurement –  Line levelling
3.  CODE –  Line adjustment
4.  PtID & Incremen –  Check & Adjust
5.  Manual Input
•  Start programs (PROG) •  Coding
–  Job •  Menu settings
–  Line
•  Data manager
–  Tolerances
–  Method •  Data storage
–  Memory mode

Maa-6.3261 48
octavian.andrei@aalto.fi
AaltoENG
Maa-6.3261 49
octavian.andrei@aalto.fi
AaltoENG
Sample Backup
Recording Sheet

Maa-6.3261 50
octavian.andrei@aalto.fi
AaltoENG
F = -13.23456 m
B = +13.23750 m
+ 0.00294 m

Allowable
Section Closure

1st Order, Class II


4√1.47782 = 4.86262 mm

2nd Order, Class I


6√1.47782 = 7.29393 mm

Maa-6.3261 51
octavian.andrei@aalto.fi
AaltoENG