Contents

Section 1. System Setting 3


1-1. Network Environment 3
1-1.1 Wired Network Environment 3
1-1.2 Wireless LAN Environment 4
1-1.3 Network Configuration Setup of BMCentral PC 5
1-1.4 Network Configuration Setup of Patient Monitor 8
1-1.5 Setup of AP(Access Point) and Ethernet Converter 10
1-1.6 Connection of AP(Access Point) and BMCentral PC 10
1-1.7 Connection of Ethernet Converter and Patient Monitor 11

1-2. Hardware Configuration 14

1-3 Wireless Network Setup 16

1-3.1 AP(Access Point) Setting : User Friendly Firmware Version 16


1-3.2 AP(Access Point) Setting : Professional Firmware Version 25
1-3.3 Ethernet Converter Setting 37

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
1
BMCentral Network Setup
Operation Manual

Section 1. System setting


1-1. Network Configuration

1-1.1 Wired Network Environment

Note

Recommend no connection with private network for safety communication with no


interruption BMCentral PC between and equipment

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
2
BMCentral Network Setup
Operation Manual

1-1.2 Wireless LAN Environment

Note

- Recommend no connection with private network for safety communication with no


interruption BMCentral PC between and equipment

- Wireless distance between AP and Patient Monitor should not exceed 30 meters based
by open space with no obstruction.

- There should be no obstruction between AP and Patient Monitor with wireless. And
wireless distance will be change by presence of obstruction

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
3
BMCentral Network Setup
Operation Manual

1-1.3 Network Configuration Setup of BMCentral PC


1) Move to Start -> Control Panel

2) Move to “View network status and tasks” in “Network and Internet”

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
4
BMCentral Network Setup
Operation Manual

3) Click “Change adapter settings”

4) Select “Local Area Connection”. click right mouse button, and move to “Properties

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
5
BMCentral Network Setup
Operation Manual

5) Move to “Internet Protocol Version 4(TCP/IPv4)”, and click "Properties".

6) Enter IP address, Subnet mask, and Default gateway used in central system network and click
"OK".

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
6
BMCentral Network Setup
Operation Manual

1-1.4 Network Configuration Setup of Patient Monitor


1) Move to “Setup”

10-JAN-2008 12:23 JOHN 00001A


BPM 150/50 mmHg RPM 30/10
P 60 80 120 20S
20
200


%SpO2 100/90 ADT 80 30.42.00 36.5

99
T1

09:58
1HR
(93) T1
42.0
30.0
36.5
0:56
PVC (/min):-, ST(mm): 0.0
ART
120
II X1

S
150 80
70 60 (90)
EtCO2 40mmHg CVP

M
15
11
BED-001 3

2) Move to “USER SERVICE”

MAIN USER
DISPLAY
MENU SERVICE

KEY
PREV SOUND:
DEMO: MAKER
MENU ON
ON SERVICE

3) Move to ”SYSTEM”

SET SET BED


MAIN UNIT NUMBER
MENU
NAME :001
AC
PREV
SYSTEM FILTER:
MENU
50HZ

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
7
BMCentral Network Setup
Operation Manual

4) Set “Central" to “On”, Enter “HOST IP”, “DEVICE IP”, “SUBNET” and “GATEWAY”. The “HOST IP”
should match the IP of BMCentral PC and “GATEWAY” should match
the GATEWAY of BMCentral
SYSTEM INFO SET
RETURN CONTENTS

MAIN VER 1.09.BHCDDCBAA


EIA VER 1.09
NBP VER 1.0
CENTRAL ON
HOST IP 192. 168.011. 090
DEVICE IP 192. 168.011. 151
SUBNET 255. 255.255. 000
GATEWAY 192. 168.011. 003
MAC ADDR 00 : 02 : BD : 80 : CB : 00
VGA OUTPUT OFF

5) Restarting Patient Monitor

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
8
BMCentral Network Setup
Operation Manual

1-1.5 Setup of AP(Access Point) and Ethernet Converter


Refer to "1-3. Wireless Network Setup".

1-1.6 Connection of AP(Access Point) and BMCentral PC


1) Connect AP to BMCentral Server PC using Direct LAN Cable(RJ45 LAN Cable)

2) Connect Power of AP.

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
9
BMCentral Network Setup
Operation Manual

1-1.7 Connection of Ethernet Converter and Patient Monitor


1) Equip with Wireless LAN Holder

2) Insert Ethernet Converter to Wireless LAN Holder from bottom to top,


Connect Converter Power Cable between Patient Monitor and Ethernet Converter

bottom to top

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
10
BMCentral Network Setup
Operation Manual

3) Connect Converter LAN Cable between Eternet Converter and Patient Monitor

4) Insert Converter to Wireless LAN Holder

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
11
BMCentral Network Setup
Operation Manual

5) For Patient Monitor to provide power to Ethernet Converter, set “W-LAN” to “ON” as follows.
<BM5>
SETTINGMAKER SERVICEW-LANON

<BM1 & BM3 & BM7>


SETTINGUSER SERVICEW-LANON

6) Restarting Patient Monitor

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
12
BMCentral Network Setup
Operation Manual

1-2. Hardware Configuration

Central system Description

 PC with installed BMCentral


program

 USB Lock Key:


For protection of Software copy

 Access Point (WZR-HP-


AG300H)

 Ethernet converter (AP-300R)

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
13
BMCentral Network Setup
Operation Manual

Central system Description

 Patient Monitor

 Converter Power Cable

 Converter LAN Cable

 Wireless LAN Holder

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
14
BMCentral Network Setup
Operation Manual

1-3. Wireless Network Setup

Note

AP(Access Point) has User Friendly Firmware Version and Professional Firmware Version
depending on nation. These two version have different setting route and you can judge
each version from Converter Setting dialogue

1-3.1 AP(Access Point) Setting : User Friendly Firmware Version


1) Press “Reset” button in the bottom of AP for 15 seconds, and AP will be initialized. (Wait until
DIAG LED light is turned off. initialization will start after DIAG LED is turned off)

Reset Button

Diag LED

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
15
BMCentral Network Setup
Operation Manual

2) Connect AP(Access Point) to PC and move to Start -> Control Panel

3) Move to “View network status and tasks” in “Network and Internet”

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
16
BMCentral Network Setup
Operation Manual

4) Click “Change adapter settings“

5) Select “Local Area Connection”. click right mouse button, and move to “Properties”.

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
17
BMCentral Network Setup
Operation Manual

6) Move to “Internet Protocol Version 4(TCP/IPv4)”, and click "Properties".

7) Enter IP address, Subnet mask, and Default gateway used in central system
network and click "OK".

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
18
BMCentral Network Setup
Operation Manual

8) Connect AP with PC, using LAN Cable

Connect LAN Cable

9) Execute Web browser and enter "192.168.11.1" in address window

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
19
BMCentral Network Setup
Operation Manual

10) After pop up Log-in dialogue, enter “root” in User name and there’s no need to enter
Password. Click “OK”

11) After normally login, dialogue will pop up as follows. Click “Wireless SSID & Channel ”.

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
20
BMCentral Network Setup
Operation Manual

12) If “Default setting dialogue” is popped up, set SSID using AP NAME searched by wireless,
“8” at wireless Channel and “20Mhz” at bandwidth on 802.11n/g/b. Click “APPLY”

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
21
BMCentral Network Setup
Operation Manual

13) After saving default setting, move to “Wireless -> Basic (11n/g/b)” and finish setting
encryption as shown below. SSID Name must be the same SSID Name, which was registered
in the default setting. Set the rest of items in the same way. ( WPA-PSK(Pre-Shared Key) will
be set by the administrator)

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
22
BMCentral Network Setup
Operation Manual

14) After applying wireless configuration, move to “WAN / LAN” and designate own’s IP. Release
Check on “Enable” in “DHCP Server”. Access Point’s IP will be set this step. After applying, close
explorer window.

Afterwards, when you connect again for AP(Access Point) Setting, you should not enter the
address [ 192.168.1.1] on the web browser. Instead, you must enter the IP address of the AP,
which you set previously. The IP address of the PC must be the same as that of the AP to the
3rd dotted decimal with the final dotted decimal being different

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
23
BMCentral Network Setup
Operation Manual

1-3.2 AP(Access Point) Setting : Professional Firmware Version


1) Press “Reset” button in the bottom of AP for 15 seconds, and AP will be initialized. (Wait until
DIAG LED light is turned off, initialization will start after DIAG LED is turned off)

Reset Button

Diag LED

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
24
BMCentral Network Setup
Operation Manual

2) Connect AP(Access Point) to PC and move to Start -> Control Panel

3) Move to “View network status and tasks” in “Network and Internet”

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
25
BMCentral Network Setup
Operation Manual

4) Click “Change adapter settings”

5) Select “Local Area Connection”, click right mouse button, and move to “Properties”.

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
26
BMCentral Network Setup
Operation Manual

6) Move to “Internet Protocol Version 4(TCP/IPv4)”, and click "Properties".

7) Enter IP address, Subnet mask, and Default gateway used in central system
network and click "OK".

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
27
BMCentral Network Setup
Operation Manual

8) Connect AP with PC, using LAN Cable

Connect LAN Cable

9) Execute Web browser and enter "192.168.11.1" in the address window

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
28
BMCentral Network Setup
Operation Manual

10) After finish connection with AP and PC, open explorer and enter [192.168.11.1] in the address
window

11) If Router Password dialogue is popped up as follows, Insert User Name and Password and
Click “Change Password”. User Name and Password in here will be used when change AP
setting

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
29
BMCentral Network Setup
Operation Manual

12) After insert User Name and Password, Move to Setup -> Basic Setup, set as follows and
click “Save” button.

Select
Disabled

Enter AP’s
IP Information

DHCP
Disable

Click

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
30
BMCentral Network Setup
Operation Manual

13) After enter setup -> Basic Setup, move to Setup -> Advanced Routing, set as follows and
click “SAVE” button.

Select Router

Select
LAN&WLAN

Click

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
31
BMCentral Network Setup
Operation Manual

14) After enter setup -> Advanced Routing information, move to Wireless -> Basic Setting, set
as follows and click “SAVE” button.

Set all setting vaule same


as follows except SSID.
You can set SSID value
searched by wireless AP
from Converter

Click

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
32
BMCentral Network Setup
Operation Manual

15) After enter Wireless->Basic Setting information, move to Wireless->Wireless Security, set
as follows and click “SAVE” button.

Set all setting vaule same


as follows except WPA
Click Shared Key.

You can set WPA Shared


Key value used in
Converter connection
setting

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
33
BMCentral Network Setup
Operation Manual

16) After enter Wireless->Wireless Security information, move to Services->Services, set as


follows and click “SAVE” button.

Select Disable

Click

17) After enter Services ->Services information, move to Security->Firewall, set as follows and
click “SAVE” button.

Select Disable

Click

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
34
BMCentral Network Setup
Operation Manual

18) After enter Security ->Firewall information, move to Administration->Management, set as


follows and click “Apply Setting” button.

Check Enabled

Click

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
35
BMCentral Network Setup
Operation Manual

19) Close web browser window once setting is completed. Afterwards, when you

connect again for AP(Access Point) Setting, you should not enter the address [ 192.168.1.1] on
the web browser. Instead, you must enter the IP address of the AP, which you set previously.
The IP address of the PC must be the same as that of the AP to the 3 rd dotted decimal with the
final dotted decimal being different

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
36
BMCentral Network Setup
Operation Manual

1-3.3 Ethernet Converter Setting


1) Connect LAN Cable between Ethernet converter and PC as follows, and Connect with Power
to Converter

2) Initialize Ethernet Converter by pressing “Reset”button for 10 seconds.

RESET Button

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
37
BMCentral Network Setup
Operation Manual

3) Move to Start -> Control Panel

4) Move to “View network status and tasks” in “Network and Internet”

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
38
BMCentral Network Setup
Operation Manual

5) Click “Change adapter settings”

6) Select “Local Area Connection”, click right mouse button, and move to “Properties”.

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
39
BMCentral Network Setup
Operation Manual

7) Move to “Internet Protocol Version 4(TCP/IPv4)”, and click "Properties".

8) Enter IP address, Subnet mask, and Default gateway used in central system
network and click "OK".

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
40
BMCentral Network Setup
Operation Manual

9) Pressing “MODE” button on the side of Ethernet Converter, move to LED front to
“Client+AP”

10) After finish connection with Ethernet Converter and PC, open Internet Web browser and
enter [192.168.2.1] in the address window

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
41
BMCentral Network Setup
Operation Manual

11) If Log-in dialogue is popped up, enter “admin” in User name and Password. Click “OK”

12) After normally login, check dialogue as “Client +AP MODE” Setting dialogue. And Click
“Next”

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
42
BMCentral Network Setup
Operation Manual

13) If client setting dialogue is came out, set encoded information of AP and Channel same
with AP Setting. And click “Search”.
Channel: 8
Security Mode: WPA2-PSK
WPA/WPA2: AES
Pass Phrase: bionet1234

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
43
BMCentral Network Setup
Operation Manual

14) Select AP which you want to connect in the retrieved wireless AP and click “NEXT” (AP
displays SSID value which registered at the time of set up AP)

15) No change on wireless default setting dialogue, and click “NEXT”

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
44
BMCentral Network Setup
Operation Manual

16) Check “Wireless security setting”screen same with AP encoded information. If not, modify
to equal information and click “NEXT”

17) If “Setting Wizard”screen is came out, click “Apply” button and click OK.

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
45
BMCentral Network Setup
Operation Manual

18) Apply setting as follows, wait until finish restarting

19) After restarting, Log-in dialogue is popped up as follows. Then, separate Converter from PC
and connect to Patient Monitor

All rights copyrighted


Copyright ⓒ 2004 BIONET Co.,LTD

#1101 11F E&C Venture Dream Tower3 38-21, Digital-Ro, 31-Gil, Guro-Gu,
Seoul 152-719, REPUBLIC OF KOREA
TEL: 82-70-7585-6418 FAX: 82-70-7585-6454/6499
46