Vous êtes sur la page 1sur 1

REINFORCEMENT DESIGN OF BASE SLAB(Type-1)

BASE PRESSURE DIAGRAM FROM STABILITY RESULTANT BASE PRESSURE


Force 34.28 kN
Lever arm 0.61 m
47.30 -57.15 -11.40
kN/m2 kN/m2 kN/m2

12.50
2
kN/m
72.49 86.22
2 2
2.65 48.40 84.99 98.72 For Bending kN/m 23.81 kN kN/m
kN/m 2
kN/m 2
kN/m 2
kN/m 2 Moment& Shear force
0.15 m

1.00 0.800 0.30


m m m
INPUT DATA
Charactristic Strength of Concrete fc' 20.00 N/mm2 Yield Strength of Steel fy 420.00 N/mm2
Width of Section Considered for Design b 1000.00 mm Thickness of Concrete t 500 mm
Clear Cover c 75.00 mm Dia. of Bar Toe Slab Φ 12.00 mm
Effective Cover (Toe) d' = c + Φ/2 81.00 mm Dia. of Bar Heel Slab Φ 12.00 mm
Effective Cover (Heel) d' = c + Φ/2 81.00 mm
Minimum Percentage of Steel(50% on each
pt,min 0.18 % Effective Depth Toe Slab d = t - d' 419.00 mm
face)
Load Factor (Conservatively) 1.50 Effective Depth Heel Slab 419.00 mm
FORMULA USED
Area of Steel for Bending Moment Ast = 0.85*fc'/fy*(1 - √(1 - 2.61*R))*b*d mm2
2
R Mu/fc'bd2 N/mm
Percentage of steel provided pt = Ast*100/(b*d) %
Shear strength of Concrete without shear reinforcement
Vc=0.75*0.17*λ*Sqrt(fc')*b*d/1000 kN
DESIGN OF TOE SLAB
Factored Bending Moment Mu 5.51 kNm R = Mu/(fc'*b*d2) 0.0016
2
Area of Steel Required Ast,req 34.77 mm Spacing Required 251.20 mm
Minimum Area of Steel Ast,min 450.00 mm2 Spacing Provided 250.00 mm
Area of Steel Provided Ast,prov 452.16 mm2 Percentage of Steel provided 0.108 %
Factored Shear Force at d distance Vu 35.71 kN Shear strength of Concrete 238.913 kN
DESIGN OF HEEL SLAB
2
Factored Bending Moment Mu 31.43 kNm R = Mu/(fc'*b*d ) 0.01
2
Area of Steel Required Ast,req 199.27 mm Spacing Required 251.20 mm
Minimum Area of Steel Ast,min 450.00 mm2 Spacing Provided 250.00 mm
2
Area of Steel Provided Ast,prov 452.16 mm Percentage of Steel provided 0.108 %
Factored Shear Force at face Vu 51.42 kN Shear strength of Concrete 238.913 kN

2
Distribution reinforcement mm 450.000
Dia of distribution bar mm 12.000
Spacing mm 250.000
Area of distribution 2
mm 452.571
reinforcement provided
CRACK WIDTH CALCULATION
Modulus of Elasticity of Steel Es 200000 N/mm2 Modular Ratio, m=41.53/sqrt(fc') 9.29
Parameters Units Toe Slab Heel Slab
Steel Area ratio ρ = Ast,prov/(b*d) 0.00108 0.00108
2
Depth of neutral axis {x = nd = [√(2*ρ*m+(ρ*m) )-ρ*m]} mm 55.27 55.27
Cracked Moment of Inertia {Icr = bx3/3 + mAst(d-x)2} mm4 6.1E+08 6.1E+08
2
Stress in Steel fst = m*M*(d-x)/Icr N/mm 20.28 115.68
2
A 2*(D-d)*b mm 1.0E+09 9.99E+08
β (D-x)/(d-x) 1.22 1.22
Wcr 0.046*β*fs*cuberoot(dc*A)*10-6 mm 0.005 0.03
<0.25mm <0.25mm
Dia. and spacing of the reinforcement has been adjusted in the reinforcement drawings for the ease of construction , keeping requirement of
reinforcement into consideration.