HIGH AMBIENT VRF R-410A 50/60HZ

HEAT PUMP / HEAT RECOVERY


JUOD 080 to 360 VPEM0AS (50Hz)
JUOD 080 to 360 VPEF0AS (60Hz)
A complete range from 8hp to 36hp
YORK® Variable Refrigerant Flow System

Efficiency and comfort for your customers.


New growth opportunities for your business.

Building climate control is about comfort and efficiency – delivering


just the right heating and cooling to every space using no more
energy than necessary. YORK® variable refrigerant flow (VRF)
technology lets you do that for customers in innovative ways that
present new growth opportunities for your business.

VRF technology gives building owners, architects, consulting


engineers, and mechanical contractors an innovative solution to
address the common challenge of reducing operating costs in
buildings with varied loads and occupancy rates while delivering
comfort to all areas. The systems can offer:

• Exceptional efficiency, delivering an average of up to 39% energy


savings for some applications compared to conventional HVAC
systems.

• Flexibility to specify a customized modular system to the


exacting requirements of each project, with options that include
heat pump and a host of fan coil options.

• Freedom for designers to choose ducted systems with short


or long runs, or ductless systems that allow for much lower
clearance between building floors and therefore lower overall
construction costs.

• Impressively quiet comfort, with control to deliver precisely the


correct amount of heating or cooling to each zone.

The information contained in this catalog is for illustration purposes only and is
subject to change at the sole discretion of Johnson Controls. Statements, figures,
calculations, plans, images and representations are only examples. Johnson Controls
encourages you, as the purchaser, to analyze your HVAC requirements and to work
with Johnson Controls to determine the exact VRF System to fulfill your needs.

1
Introducing YORK® VRF from Johnson Controls

YORK® VRF systems are modular and


controlled solutions that include models with
capability to simultaneously heat and cool
different zones.

The technology brings an array of advantages over conventional


systems.
•S
 ave on energy. Systems essentially eliminate duct losses. In
addition, variable-speed compressors in outdoor units provide
extremely high part-load efficiency.
•K
 eep people comfortable. Users can set individual temperature
set points for multiple zones. Variable-speed compressors with
wide capacity and precise modulation help maintain each zone’s
temperature within a narrow range. Indoor units also operate
quietly.
• Go green. VRF technology can help users attain LEED® certification
points for resource efficiency.

Enjoy design freedom


A variety of standard modular components let you customize
and size equipment to meet specific project requirements.
Because ductwork is generally needed only for ventilation, ducts
can be smaller, reducing capital cost. Systems can easily be adapted
as space is reconfigured. Unlike conventional HVAC systems, VRF
systems allow addition of capacity to accommodate expansion simply
by adding modular units (capacities 8-54 HP). There is no need to
remove and replace the original unit or reconfigure ductwork.

Install with ease


YORK® VRF systems are designed for quick and simple
installation, since piping from the outdoor units can be connected
from the front, back, or underneath. Indoor units are relatively small
and light and easy to transport and handle; outdoor units can be
brought into a building for installation on a rooftop via a service
elevator – no crane or other heavy equipment is needed. Service is
simple, too: Systems need little maintenance beyond changing filters
and cleaning coils. Removal of a single panel provides easy access to
all components: control boards, electrical connections, compressor
and piping.

2
Gain flexibility control
Users can choose from three basic control options.
• Indoor fan coil units come with a selection of thermostats using
wired remote control, from simple units with on/off, setpoint, load
and speed settings, to programmable units that enable scheduling.
Wireless units are available to provide remote control of zone space
conditions.
•C
 entral station controllers for larger projects provide remote
control and scheduling of the entire system from one or more
control points.
• Adapters (gateways) enable control of large buildings or campuses
through building automation systems such as Metasys®.

Choose multiple applications


YORK® VRF systems suit a wide range of buildings in new
construction and retrofits. Prime candidates include:
• Buildings with multiple zones that have different comfort needs –
such as hotels, schools, medical office buildings, commercial office
buildings and others.
• Historical building renovations in which ducted HVAC options
are severely limited and the basic building structure must not be
disturbed.
• Buildings in climate zones favorable for heat pump technology.

3
Get expert advice at every step: select, design, specify, install

Your Johnson Controls account team supports you as no one


else can, at every step of every project. Effective training, intuitive
design and specification software, advanced logistics and delivery,
and easily accessible documentation form a powerful support
package that adds substantial value to YORK® VRF systems.

Get your team up to speed fast.


Efficient performance, quality installations.

Comprehensive training programs provide knowledge and


skills necessary to effectively and efficiently use YORK® VRF
technology. Our world-class VRF training center offers a multitude
of classes with specialized modules and topics that help:

• Salespeople submit competitive bids and close deals.

• Designers select and configure the right equipment easily


and accurately.

• Installers learn the proper procedures and complete jobs


accurately, on time and on budget.

• Service technicians maintain, troubleshoot and repair systems


efficiently.

The training center includes a dedicated VRF laboratory


to provide hands-on experience with the various systems,
components and controls. Videos and webinars supplement
classroom learning on specific subjects and refresh and enhance the
skills of your sales, design, installation, and service teams. YORK®
VRF training programs help deliver peace of mind that your staff is
prepared to support your business with the knowledge to compete in
a growing industry.

4
Get the tools that give you an edge

Right-size systems with intuitive selection software

The YORK® VRF selection software intuitively guides you step


by step through equipment selection, so you can quickly and
accurately choose an appropriate and cost-effective equipment
package for each project.

PC-based program

The PC-based program gives you mobility and flexibility. The


software helps you:
• Design accurate final system drawings including piping and wiring
diagrams in an easy, quick, step-by-step process.
• Accurately select systems using a System Sizing Analysis. The
process starts with the indoor fan coil units, so that outdoor units
are optimally sized. Proprietary algorithms figure the system size
using data input on the indoor units, load, and measurements, so
your system does not include capacity that will go unutilized.
• Use intuitively designed features and functionality that make the
design process easy, fast, and accurate. You can select options
and accessories without referring to additional information or
performing additional calculations.
• Gain an edge by confidently designing VRF systems that are right-
sized, and include the right equipment for each project.

5
Consistent delivery:
Get the right equipment to the jobsite on time

Ample inventory and advanced order management and logistics


systems can help you complete installations in a timely manner.
Consistent service and predictable deliveries help you prevent delays
waiting for essential components and enable you to set a project
timeline and schedule labor efficiently. Fast and accurate parts
delivery from our main distribution center.

Let’s go to work – together

YORK® VRF systems can be configured to meet your project


requirements and deliver exceptional performance. Select Heat
pump or Heat recovery outdoor units with DC inverter-driven
compressors offering energy savings and the ability to scale to size.
Indoor units for ducted or ductless applications offer optional motion
sensing control for even greater energy savings. Multiple ventilation
options help make sure your systems introduce the right volume of
outside air. A host of options and accessories help ensure a custom
fit for your project. And users benefit from our variety of control
technology options.

Let’s explore the many advantages of VRF systems together so you


can put them to work for your customers. On these pages, you can
explore detailed information on the full range of YORK® VRF systems.

6
Introducing a new addition to York’s VRF
range of VRF air conditioning units - enhancing
efficiency and user experience

YORK® Variable Refrigerant Flow System


There is increasing demand for a holistic approach to air conditioning in modern offices - units
that are capable of simultaneously cooling and heating, adapting to the different seasons and
various temperature requirements of rooms.
Customers also want to save time, money and space with their air conditioning and
have the flexibility to extend or modify their air conditioning set-up to suit changing needs.
And of course there is a growing demand for air conditioning to be as environmentally friendly
as possible - enabled through an air-conditioning management system that makes it easier for
users to have simple, effective control of their air conditioning units to avoid unnecessary energy
wastage, including overheating, overcooling and unattended operation.
To meet and exceed these important requirements,
York has developed the YORK High Efficiency VRF air conditioning system.

YORK VRF JUODVPEM0AS / JUODVPEF0AS


Compatible with York’s system free indoor units
Wide product range
JUODVPEM0AS/JUODVPEF0AS (High Ambient High efficiency Type): 8 to 36HP 
Energy saving
-Heat recovery and DC Inverter Driven Compressor
Flexibility of Installation
-Compact and light design and flexible refrigerant piping
Comfort and Reliability
-Capable of impressively low noise levels with
noise reduction preference mode (option)
Control by Network System

7
Capable of Heat Recovery and 2-pipe Heat Pump Operations
York’s outdoor units feature a heat recovery operation system as well as a 2-pipe heat pump
operation system. This avoids the need for review work when designing the equipment layout,
while reducing the workload and time spent installing the units on site.

York VRF (Module Type)


When used as a When used as a
heat recovery operation system 2-pipe heat pump operation system

3-pipes Heat recovery and 2-pipe heat pump


2-pipes
operations common unit
CH units

High Ambient JUOD: 14 models


(Base unit 3models)

The heat recovery and 2-pipe heat pump operation systems cannot be switched over after installation is complete.

York air conditioning successfully meets installer and


customer demands - offering greater functionality,
control and cost savings

Needs of End Users Needs of Consultants Needs of Contractor and installer


■ Heat recovery operation ■ Time saving with equipment ■ Modular and lightweight for
■ Energy efficient  layout design   quicker (or phased) installations
■ Greater user control ■ Flexible, modular system designs ■ Increased piping lengths
■ Flexibility to extend system ■ Intelligent controls   for flexibility

8
Heat Recovery Operation
Heat Recovery Operation Significantly Enhances Energy-saving Efficiency
A heat recovery system offers high energy-saving efficiency by drawing heat from the rooms to be cooled,
and effectively using it as a heat source for the rooms to be heated.

Existing system (2-pipe heat pump operation )

10HP 10HP
heat radiation
Multiple 2-pipe heat pump units are required
heat absorption
when there are different air-conditioning
needs in one building.

heat release

heat release

heat absorption

heat absorption
Cooling with Heating with
50% capacity 50% capacity

JUODVPEM / JUODVPEF(heat recovery operation)

With the heat recovery operation, the heat


is effectively used as a source of heating.

10HP
heat release

heat release

heat absorption

heat absorption

Heat Recovery Operation


Lower Equipment Cost & Power Consumption
with 50% capacity Compared with Existing System*
* If the ratio of cooling and heating loads is 50:50, the power
consumption of one heat recovery unit can cover the
operation of two 2-pipe heat pump units.

9
System Configuration
Outdoor Unit Refrigerant Piping Transmission
Heat recovery and 2-pipe heat pump operations common unit Max. length: 165m Corresponding to H-LINK

Module type (external connection) Total length: 1,000m Max. 64 refrigerant groups
Max. 160 indoor units

Connectable Indoor Unit


Max. 59 units
Capacity range: 50-130%

CH Unit (heat recovery system only)


Changeover box for heat recovery application
Compact and light design
Minimized unit and less suspension bolts facilitate installation
and handling methods.
Specifications Indoor Unit Connection
Model Dimension Net Weight Number of
Total HP
W x D x H (mm) (kg) Indoor Units*
6HP 1~7
Remote Control Switch Central Station
JCH-6.0N2S
301 x 214 x 191 7
JCH-10.0N2S 6.1HP to 10HP 1~8

* When multiple indoor units are connected to same CH unit,


they are controlled with same operation mode.

NOTE:When switching the refrigerant flow channel at Operation ON/OFF, Thermo ON/OFF,
Defrost Operation and Operation Mode, refrigerant flow noise may be heard from CH Unit.
Therefore install the unit in a place such as under the roof of corridor so that the sound
may not be heard in the room.

10
Product Line-up
Choose the best suited model from a selection of each base unit used individually or in combinations.
All integrating heat recovery and heat pump operation suit the customer requirements.

Outdoor Unit
Base Unit (3models)

8HP 12HP 16HP 18HP 20HP 26HP 28HP 30HP

10HP 22HP 24HP 32HP 34HP 36HP

Refer to "GENERAL DATA" for information on the combination of base units.

(HP)
O.6 O.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 3.3 4.0 5.0 6.0 8.0 10.0
Indoor Unit (kW)
1.6 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1 8.4 9.0 11.2 14.2 16.0 22.4 28.0

Four-Way Cassette

Mini Four-Way
Cassette

Two-Way Cassette

Slim Ducted

Compact Ducted

Low Static Ducted

Medium Static Ducted

High Static Ducted

Medium Static Ducted (SMZ)

High Static Ducted (SMZ)


* *
Ceiling Suspended

High Wall

* Coming Soon

11
Energy-saving and Comfort
New Type DC Inverter Scroll Compressor
Discharge Pressure Space
Improved Intermediate Pressure Performance Valve Open
Pressure
Control Valve
The intermediate pressure performance is drastically improved by using a release valve (Release Valve)

and optimizing orbiting scroll lifting force in the improved new compression mechanism. Hole for Release Valve

Therefore, intermediate pressure performance is largely improved for energy-saving.


Compression
Space
Release valve adoption prevents over compression. Fixed Scroll

Orbiting scroll lifting force optimization has achieved leakage loss reduction. Pressure at
Discharge Pressure
Compression Space
JUOD series is all inverter models.

Capacity Control by 1 Hz Wide Working Range


Performance is greatly improved by the high efficiency DC JUOD Series can handle a wide range of outside air
inverter compressor and conditions, thus extending the flexibility of installation space
100%
loss-less energy saving 12 HP and climatic environment.
Compressor Control Capacity

operation is achieved 15Hz~100Hz


(depending on the
No. 1
85Steps -20˚C
Heating (WB)
15˚C
building). Inverter Cooling (DB)
Compressor -5˚C 52˚C
20% -20 -10 0 10 20 30 40 50
Max. Min.
Cooling Load

Self-demand Control Excessive power supply Power Setting


Selectable from 100%, 80%,
consumption exceeding the 70% and 60% of the rated
A newly developed self-demand function has largely improved power setting range is restricted. power consumption for cooling
operation.
Power Consumption

energy-saving effects. Since the current is self-detected and


demand control is performed automatically, no signal wiring
work is required. Conventional demand control using demand Maximum efficiency is secured within the
power setting range.
signals is also available, and you can select various operations NEW
as required. Morning Daytime Night
Operation Hours

12
Flexibility of Installation

Compact and Light Design


Transportation and Handling using Elevator
The elevator can be used to transport the JUOD080VPEMOAS/JUOD080VPEFOAS
base unit separately. to
JUOD120VPEMOAS/JUOD120VPEFOAS

1,720mm
765mm
1,210mm

Basic Unit Can Be Carried in an Elevator


Elevator
Door Opening: 800 mm
Depth: 1350 mm

Improvement of Workability
The piping connection work is newly available from the refrigerant piping outlet
(right bottom side of the front cover) in addition to three directions (front, rear or bottom) from the bottom base.

Newly Added

2 Control Power Source


Cable Outlets Cable Outlet

No trap is
required.

Front Cover
Refrigerant Piping Outlet

A new piping outlet is provided on the lower right side of the front cover and so the piping
connection kit can be installed at the lower position.
This makes an easy and clear installation of the piping from multiple outdoor units possible.

13
More Flexible Refrigerant Piping Work

Improved flexibility of design by increasing the total pipe length


to 1,000 m max.

Heat Pump System Heat Recovery System


1 1
1 Max. piping length 165 m* 165 m*
4
2 Between first branch 5
and indoor unit
90m or less *2
90m or less *2

3
Height difference between
3
highest and lowest indoor units
30m or less 15m or less
Height difference between
50m* 50m*
4 3 3
2
outdoor and indoor units 1
*2*4
Sales on order 90m or less
Max. length between branch
5
from indoor units
40m 40m

NOTES
*1: For 100m or more, the pipe diameter will be one size larger.
*2: There’re restrictions for connectable indoor units and refrigerant amount.
Please refer to technical manual for details.
*3: In case the outdoor unit is installed at a higher level than indoor units.
If the outdoor unit is installed lower than indoor units, the maximum height difference is 40m.
*4: In case the outdoor unit is installed at a higher level than indoor units, and only when it is a base unit.

Connectable to 59 Indoor Units Max.


The number of connectable indoor units has been increased to 59 maximum.
Thus, the system can be used in buildings where there are many indoor units to be connected.

Connection Capacity: 50 to 130%


Outdoor units Capacity (HP) 8 10 12 16 18 20 22 24 26 28 30 32 34 36

Max. Number of
13 16 19 26 26 33 36 40 43 47 50 53 56 59
Connectable Indoor Units

NOTES
*: For a system in which all indoor units are operated simultaneously, the max. total capacity will be 100%.
Determine the number of Indoor Units carefully so that a problem such as decreased outlet air temperature will not occur.
Refer to Technical Catalog for more details.

*: Make
Compared to indoor units of over 4.3kW, indoor units of 1.6 to 2.8kW are set with higher air flow.
sure to select appropriate indoor units when installing indoor units where cold draft may occur during heating operation.
Determine the usage environment and installation location carefully.

14
Other Advanced Technologies
Rotational Operation*1 to Distribute Load of Outdoor Units
Regulating the operation time of each outdoor unit leads to load reduction on compressors.*2
During multiple unit operation, the same rotation frequency of inverter compressor results in
an equivalent load on each compressor. Therefore, outdoor unit endurance is improved.

Inverter Compressor Rotation Frequency Control (Example) Last Time

At the time of compressor


start-up, or when 2 hours has
One Unit Two Units Three Units passed from start of operation. Activation
3 2 1
Operation Operation Operation Order

It is operated so that the


This Time
Revolution of Inverter Compressor

revolution of the inverter


compressor 1 and 2 may
3 become the same.

Activation
Revolution of 2 Order 2 1 3
2 2

Revolution of 1
1 1 1 Next Time

Low Hi
Operating Load

NOTES Activation
1
*1: At least 2 outdoor units are required for this function. Order 3 2

*2: Comparison between rotation operation function and non-rotation operation


function based on the same system.

Backup Operation Function for Emergency Even if one unit fails,


the other can be operated continuously.*2
The Backup Operation Function prevents the system from coming to
a complete stop when outdoor unit failure occurs.*1 Emergency
operation starts with the remote control switch after an alarm.*3

x
Failed Outdoor Unit

NOTES
*1: At least 2 outdoor units are required for this function.
*2: Emergency operation can be performed within 8 hours after unit stoppage.
After 8 hours pass from unit stoppage, emergency operation can not be Emergency Operation Indication
Press " TEMP. "
performed.
simultaneously
*3: Emergency operation can be performed when the specified alarm code
occurs. Refer to “Alarm Code for Emergency Operation”. for 3 seconds.

[EMG] is displayed on the LCD of


the remote control switch,
and emergency operation starts.

15
Noise Reduction Preference Mode (Optional Function)
With the new Noise Reduction Preference Mode, the sound pressure level for a particular time zone can be set based upon
the usage environment. *1 Therefore, the operation/management of air conditioners is facilitated in areas where the noise
level at night time is restricted by laws and regulations.

You can select from 3 sound pressure levels

Optional Sound Pressure


Setting from Outdoor Unit
Noise Reduction Level (dB)
Input and Output Function
Function (Approx. Value)

11 Setting 1 55

12 Setting 2 50

13 Setting 3 45 Setting Example


Low-Sound Operation during Night Time only by Using Timer
NOTES
*1: The range of performance and operation is restricted, because the rotation Input Signal *
frequency of the compressor and outdoor fan is forcibly decreased. Daytime Daytime
100%
Capacity
Night time
(Ratio)
60%

Daytime Daytime
Sound Pressure Night time
Level

50dB

Time

*: Perform the electrical wiring work on site when setting input signal.

High External Static Pressure


The outdoor units provide external static pressure up to 60Pa by
setting at site for installation on each floor of the building.

16
General Data (50Hz)
Model JUOD080VPEM0AS JUOD100VPEM0AS JUOD120VPEM0AS JUOD160VPEM0AS JUOD180VPEM0AS JUOD200VPEM0AS JUOD220VPEM0AS
- - - JUOD080VPEM0AS JUOD080VPEM0AS JUOD080VPEM0AS JUOD100VPEM0AS

Combination of Base Unit - - - JUOD080VPEM0AS JUOD100VPEM0AS JUOD120VPEM0AS JUOD120VPEM0AS

- - - - - - -

Power Supply 3N~ , 380-415V/50Hz

kW 22.4 28.0 33.5 45.0 50.0 56.0 61.5


Capacity
Cooling (1) Btu/h 76,000 96,000 114,000 154,000 170,000 192,000 210,000

35℃ Power Input kW 5.12 7.66 9.60 10.30 12.67 14.75 17.26
(Nominal) (Btu/h)/W 14.85 12.55 11.90 14.95 13.40 13.00 12.15
EER(2)
kW/kW 4.38 3.66 3.49 4.37 3.95 3.80 3.56

kW 20.2 22.8 26.8 40.4 43.0 47.0 49.6


Capacity
Btu/h 69,000 78,000 91,000 138,000 146,000 160,000 170,000
Cooling (2)
Power Input kW 6.86 8.78 9.81 13.72 15.64 16.67 18.59
46℃
(Btu/h)/W 10.05 8.90 9.30 10.05 9.35 9.60 9.15
EER(2)
kW/kW 2.94 2.60 2.73 2.94 2.75 2.82 2.67

kW 17.2 20.0 21.4 34.4 37.2 38.6 41.4


Capacity
Btu/h 58,500 68,000 73,000 117,000 127,000 132,000 142,000
Cooling (3)
Power Input kW 5.77 7.36 6.76 11.54 13.13 12.53 14.12
48℃
(Btu/h)/W 10.15 9.25 10.80 10.15 9.65 10.55 10.05
EER(2)
kW/kW 2.98 2.72 3.17 2.98 2.83 3.08 2.93

kW 25.0 31.5 37.5 50.0 56.0 63.0 69.0


Capacity
Btu/h 85,000 107,000 128,000 170,000 192,000 214,000 236,000
Heating
Power Input kW 5.36 6.74 9.12 10.71 11.97 14.61 15.86
(Nominal)(4)
(Btu/h)/W 15.85 15.90 14.05 15.85 16.05 14.65 14.90
COP
kW/kW 4.66 4.67 4.11 4.67 4.68 4.31 4.35

Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)

Sound Pressure Level Maximum


[Overall A Scale] (Night-Shift) dB 58(53) 59(54) 61(56) 61(56) 62(57) 63(58) 64(59)

Outer Dimension H×W×D mm 1,720 x 1,210 x 765 1,720 x 2,440 x 765

Net Weight kg 260 260+260

Gross Weight kg 275 275+275

Refrigerant - R410A

Compressor Quantity - 1 1 1 1+1 1+1 1+1 1+1


(Scroll) Motor Output (Pole) kW 4.8(6) 6.0(6) 7.2(6) 4.8(6)+4.8(6) 4.8(6)+6.0(6) 4.8(6)+7.2(6) 6.0(6)+7.2(6)

Quantity - 1 1 1 2 2 2 2
Condenser Fan
Air Flow Rate m2/min 160 175 195 160+160 160+175 160+195 175+195
(Propeller Fan)
Motor Output (Pole) kW 0.40(8) 0.52(8) 0.66(8) 0.40(8)+0.40(8) 0.40(8)+0.52(8) 0.40(8)+0.66(8) 0.52(8)+0.66(8)
Main Refrigerant Piping
Heat Pump System (2 Piping)
Liquid Line mm[in.] φ9.52[3/8] φ9.52[3/8] φ12.7[1/2] φ12.7[1/2] φ15.88[5/8] φ15.88[5/8] φ15.88[5/8]

Gas Line Low Pressure mm[in.] φ19.05[3/4] φ22.2[7/8] φ25.4[1]* φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8]
Main Refrigerant Piping
Heat Recovery System (3 Piping)
Liquid Line mm[in.] φ9.52[3/8] φ9.52[3/8] φ12.7[1/2] φ12.7[1/2] φ15.88[5/8] φ15.88[5/8] φ15.88[5/8]

Gas Line Low Pressure mm[in.] φ19.05[3/4] φ22.2[7/8] φ25.4[1]* φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8]

Gas Line High/Low Pressure mm[in.] φ15.88[5/8] φ19.05[3/4] φ22.2[7/8] φ22.2[7/8] φ22.2[7/8] φ22.2[7/8] φ25.4[1]*

Refrigerant Charge kg 7.7 7.7 8.3 15.4 15.4 16.0 16.0

Packing Dimensions H×W×D mm 1,895 x 1,250 x 810 - - - -

Approx. Packing Measurement m2 1.92 - - - -

17
Model JUOD240VPEM0AS JUOD260VPEM0AS JUOD280VPEM0AS JUOD300VPEM0AS JUOD320VPEM0AS JUOD340VPEM0AS JUOD360VPEM0AS
JUOD120VPEM0AS JUOD080VPEM0AS JUOD080VPEM0AS JUOD080VPEM0AS JUOD080VPEM0AS JUOD100VPEM0AS JUOD120VPEM0AS
Combination of Base Unit JUOD120VPEM0AS JUOD080VPEM0AS JUOD080VPEM0AS JUOD100VPEM0AS JUOD120VPEM0AS JUOD120VPEM0AS JUOD120VPEM0AS
- JUOD100VPEM0AS JUOD120VPEM0AS JUOD120VPEM0AS JUOD120VPEM0AS JUOD120VPEM0AS JUOD120VPEM0AS
Power Supply 3N~ , 380-415V/50Hz
kW 69.0 73.0 80.0 85.0 90.0 95.0 100.0
Capacity
Cooling (1) Btu/h 236,000 250,000 272,000 290,000 308,000 324,000 342,000
35℃ Power Input kW 19.90 17.96 20.36 22.72 24.49 26.86 28.63
(Nominal) (Btu/h)/W 11.85 11.90 13.35 12.75 12.60 12.05 11.95
EER
kW/kW 3.47 4.06 3.93 3.74 3.67 3.54 3.49
kW 53.6 63.2 67.2 69.8 73.8 76.4 80.4
Capacity
Btu/h 182,000 216,000 230,000 238,000 252,000 260,000 274,000
Cooling (2)
Power Input kW 19.62 22.50 23.53 25.45 26.48 28.40 29.43
46℃
(Btu/h)/W 9.30 9.60 9.75 9.35 9.50 9.15 9.30
EER
kW/kW 2.73 2.81 2.86 2.74 2.79 2.69 2.73
kW 42.8 54.4 55.8 58.6 60.0 62.8 64.2
Capacity
Btu/h 146,000 186,000 190,000 200,000 204,000 214,000 220,000
Cooling (3)
Power Input kW 13.52 18.90 18.30 19.89 19.29 20.88 20.28
48℃
(Btu/h)/W 10.80 9.85 10.40 10.05 10.60 10.25 10.85
EER
kW/kW 3.17 2.88 3.05 2.95 3.11 3.01 3.17
kW 77.5 82.5 90.0 95.0 100.0 106.0 112.0
Capacity
Btu/h 264,000 282,000 308,000 324,000 342,000 362,000 382,000
Heating
Power Input kW 18.96 17.72 20.50 21.49 23.60 24.84 27.24
(Nominal)(4)
(Btu/h)/W 13.90 15.90 15.00 15.10 14.50 14.55 14.00
COP
kW/kW 4.09 4.66 4.39 4.42 4.24 4.27 4.11
Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)
Sound Pressure Level Maximum
[Overall A Scale] (Night-Shift) dB 64(59) 64(59) 64(59) 65(60) 65(60) 66(61) 66(61)
Outer Dimension H×W×D mm 1,720 x 2,440 x 765 1,720 x 3,670x 765
Net Weight kg 260+260 260+260+260
Gross Weight kg 275+275 275+275+275
Refrigerant - R410A
Compressor Quantity - 1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1
(Scroll) Motor Output (Pole) kW 7.2(6)+7.2(6) 4.8(6)+4.8(6)+6.0(6) 4.8(6)+4.8(6)+7.2(6) 4.8(6)+6.0(6)+7.2(6) 4.8(6)+7.2(6)+7.2(6) 6.0(6)+7.2(6)+7.2(6) 7.2(6)+7.2(6)+7.2(6)
Quantity - 2 3 3 3 3 3 3
Condenser Fan
Air Flow Rate m2/min 195+195 160+160+175 160+160+195 160+175+195 160+195+195 175+195+195 195+195+195
(Propeller Fan)
Motor Output (Pole) kW 0.66(8)+0.66(8) 0.40(8)+0.40(8)+0.52(8) 0.40(8)+0.40(8)+0.66(8) 0.40(8)+0.52(8)+0.66(8) 0.40(8)+0.66(8)+0.66(8) 0.52(8)+0.66(8)+0.66(8) 0.66(8)+0.66(8)+0.66(8)
Main Refrigerant Piping
Heat Pump System (2 Piping)
Liquid Line mm[in.] φ15.88[5/8] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4]
Gas Line Low Pressure mm[in.] φ28.58[1-1/8] φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ38.1[1-1/2]*
Main Refrigerant Piping
Heat Recovery System (3 Piping)
Liquid Line mm[in.] φ15.88[5/8] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4]
Gas Line Low Pressure mm[in.] φ28.58[1-1/8] φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ38.1[1-1/2]*
Gas Line High/Low Pressure mm[in.] φ25.4[1]* φ25.4[1]* φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8]
Refrigerant Charge kg 16.6 23.0 23.7 23.7 24.3 24.3 24.9
Packing Dimensions H×W×D mm - - - - - - -
Approx. Packing Measurement m2 - - - - - - -

NOTES:
1.The cooling and heating performances are the values when combined with our specified indoor units (Piping length : 7.5 Meters, Piping Lift : 0 Meter ).
(1) Cooling Operation Conditions : Indoor Air Inlet Temperature 26.7 oC DB / 19.4 oC WB, Outdoor Ambient Temperature 35 oC DB
(2) Cooling Operation Conditions : Indoor Air Inlet Temperature 29.0 oC DB / 19.0 oC WB, Outdoor Ambient Temperature 46 oC DB
(3) Cooling Operation Conditions : Indoor Air Inlet Temperature 26.6 oC DB / 19.4 oC WB, Outdoor Ambient Temperature 48 oC DB
(4) Heating Operation Conditions : Indoor Air Inlet Temperature 20 oC DB, Outdoor Air Inlet Temperature 7 oC DB / 6 oC WB
2. The sound pressure is based on the following conditions.
1Meter from the unit service cover surface, and 1.5 Meter from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1-2 dB.
The above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3.* If the specified main refrigerant piping on the table is not available on site, use the following pipe diameter with an appropriate reducer on site. If φ25.4 pipe is not available, please use φ28.58 pipe; If φ31.75
pipe is not available, please use φ34.92 pipe; If φ38.1 pipe is not available, please use φ41.28 pipe.
4. Except for the specified combination in the table (14-36HP), there is no other combination of the base unit.
5. The width of outer dimension, it is the value when each distance between the base outer units is specified to 20mm.

18
General Data (60Hz)
Model JUOD080VPEF0AS JUOD100VPEF0AS JUOD120VPEF0AS JUOD160VPEF0AS JUOD180VPEF0AS JUOD200VPEF0AS JUOD220VPEF0AS
- - - JUOD080VPEF0AS JUOD080VPEF0AS JUOD080VPEF0AS JUOD100VPEF0AS

Combination of Base Unit - - - JUOD080VPEF0AS JUOD100VPEF0AS JUOD120VPEF0AS JUOD120VPEF0AS

- - - - - - -

Power Supply 3N~ , 380V/60Hz

kW 22.4 28.0 33.5 45.0 50.0 56.0 61.5


Capacity
Cooling (1) Btu/h 76,000 96,000 114,000 154,000 170,000 192,000 210,000

35℃ Power Input kW 5.12 7.66 9.60 10.30 12.67 14.75 17.26
(Nominal) (Btu/h)/W 14.85 12.55 11.90 14.95 13.40 13.00 12.15
EER
kW/kW 4.38 3.66 3.49 4.37 3.95 3.80 3.56

kW 20.2 22.8 26.8 40.4 43.0 47.0 49.6


Capacity
Btu/h 69,000 78,000 91,000 138,000 146,000 160,000 170,000
Cooling (2)
Power Input kW 6.86 8.78 9.81 13.72 15.64 16.67 18.59
46℃
(Btu/h)/W 10.05 8.90 9.30 10.05 9.35 9.60 9.15
EER
kW/kW 2.94 2.60 2.73 2.94 2.75 2.82 2.67

kW 17.2 20.0 21.4 34.4 37.2 38.6 41.4


Capacity
Btu/h 58,500 68,000 73,000 117,000 127,000 132,000 142,000
Cooling (3)
Power Input kW 5.77 7.36 6.76 11.54 13.13 12.53 14.12
48℃
(Btu/h)/W 10.15 9.25 10.80 10.15 9.65 10.55 10.05
EER
kW/kW 2.98 2.72 3.17 2.98 2.83 3.08 2.93

kW 25.0 31.5 37.5 50.0 56.0 63.0 69.0


Capacity
Btu/h 85,000 107,000 128,000 170,000 192,000 214,000 236,000
Heating
Power Input kW 5.36 6.74 9.12 10.71 11.97 14.61 15.86
(Nominal)(4)
(Btu/h)/W 15.85 15.90 14.05 15.85 16.05 14.65 14.90
COP
kW/kW 4.66 4.67 4.11 4.67 4.68 4.31 4.35

Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)

Sound Pressure Level Maximum


[Overall A Scale] (Night-Shift) dB 58(53) 59(54) 61(56) 61(56) 62(57) 63(58) 64(59)

Outer Dimension H×W×D mm 1,720 x 1,210 x 765 1,720 x 2,440 x 765

Net Weight kg 260 260+260

Gross Weight kg 275 275+275

Refrigerant - R410A

Compressor Quantity - 1 1 1 1+1 1+1 1+1 1+1


(Scroll) Motor Output (Pole) kW 4.8(6) 6.0(6) 7.2(6) 4.8(6)+4.8(6) 4.8(6)+6.0(6) 4.8(6)+7.2(6) 6.0(6)+7.2(6)

Quantity - 1 1 1 2 2 2 2
Condenser Fan
Air Flow Rate m2/min 160 175 195 160+160 160+175 160+195 175+195
(Propeller Fan)
Motor Output (Pole) kW 0.40(8) 0.52(8) 0.66(8) 0.40(8)+0.40(8) 0.40(8)+0.52(8) 0.40(8)+0.66(8) 0.52(8)+0.66(8)
Main Refrigerant Piping
Heat Pump System (2 Piping)
Liquid Line mm[in.] φ9.52[3/8] φ9.52[3/8] φ12.7[1/2] φ12.7[1/2] φ15.88[5/8] φ15.88[5/8] φ15.88[5/8]

Gas Line Low Pressure mm[in.] φ19.05[3/4] φ22.2[7/8] φ25.4[1]* φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8]
Main Refrigerant Piping
Heat Recovery System (3 Piping)
Liquid Line mm[in.] φ9.52[3/8] φ9.52[3/8] φ12.7[1/2] φ12.7[1/2] φ15.88[5/8] φ15.88[5/8] φ15.88[5/8]

Gas Line Low Pressure mm[in.] φ19.05[3/4] φ22.2[7/8] φ25.4[1]* φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8]

Gas Line High/Low Pressure mm[in.] φ15.88[5/8] φ19.05[3/4] φ22.2[7/8] φ22.2[7/8] φ22.2[7/8] φ22.2[7/8] φ25.4[1]*

Refrigerant Charge kg 7.7 7.7 8.3 15.4 15.4 16.0 16.0

Packing Dimensions H×W×D mm 1,895 x 1,250 x 810 - - - -

Approx. Packing Measurement m2 1.92 - - - -

19
Model JUOD240VPEF0AS JUOD260VPEF0AS JUOD280VPEF0AS JUOD300VPEF0AS JUOD320VPEF0AS JUOD340VPEF0AS JUOD360VPEF0AS
JUOD120VPEF0AS JUOD080VPEF0AS JUOD080VPEF0AS JUOD080VPEF0AS JUOD080VPEF0AS JUOD100VPEF0AS JUOD120VPEF0AS
Combination of Base Unit JUOD120VPEF0AS JUOD080VPEF0AS JUOD080VPEF0AS JUOD100VPEF0AS JUOD120VPEF0AS JUOD120VPEF0AS JUOD120VPEF0AS
- JUOD100VPEF0AS JUOD120VPEF0AS JUOD120VPEF0AS JUOD120VPEF0AS JUOD120VPEF0AS JUOD120VPEF0AS
Power Supply 3N~ , 380V/60Hz
kW 69.0 73.0 80.0 85.0 90.0 95.0 100.0
Capacity
Cooling T1(1) Btu/h 236,000 250,000 272,000 290,000 308,000 324,000 342,000
35℃ Power Input kW 19.90 17.96 20.36 22.72 24.49 26.86 28.63
(Nominal) (Btu/h)/W 11.85 11.90 13.35 12.75 12.60 12.05 11.95
EER(2)
kW/kW 3.47 4.06 3.93 3.74 3.67 3.54 3.49
kW 53.6 63.2 67.2 69.8 73.8 76.4 80.4
Capacity
Btu/h 182,000 216,000 230,000 238,000 252,000 260,000 274,000
Cooling (2)
Power Input kW 19.62 22.50 23.53 25.45 26.48 28.40 29.43
46℃
(Btu/h)/W 9.30 9.60 9.75 9.35 9.50 9.15 9.30
EER(2)
kW/kW 2.73 2.81 2.86 2.74 2.79 2.69 2.73
kW 42.8 54.4 55.8 58.6 60.0 62.8 64.2
Capacity
Btu/h 146,000 186,000 190,000 200,000 204,000 214,000 220,000
Cooling (3)
Power Input kW 13.52 18.90 18.30 19.89 19.29 20.88 20.28
48℃
(Btu/h)/W 10.80 9.85 10.40 10.05 10.60 10.25 10.85
EER(2)
kW/kW 3.17 2.88 3.05 2.95 3.11 3.01 3.17
kW 77.5 82.5 90.0 95.0 100.0 106.0 112.0
Capacity
Btu/h 264,000 282,000 308,000 324,000 342,000 362,000 382,000
Heating
Power Input kW 18.96 17.72 20.50 21.49 23.60 24.84 27.24
(Nominal)(4)
(Btu/h)/W 13.90 15.90 15.00 15.10 14.50 14.55 14.00
COP
kW/kW 4.09 4.66 4.39 4.42 4.24 4.27 4.11
Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)
Sound Pressure Level Maximum
[Overall A Scale] (Night-Shift) dB 64(59) 64(59) 64(59) 65(60) 65(60) 66(61) 66(61)
Outer Dimension H×W×D mm 1,720 x 2,440 x 765 1,720 x 3,670 x 765
Net Weight kg 260+260 260+260+260
Gross Weight kg 275+275 275+275+275
Refrigerant - R410A
Compressor Quantity - 1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1
(Scroll) Motor Output (Pole) kW 7.2(6)+7.2(6) 4.8(6)+4.8(6)+6.0(6) 4.8(6)+4.8(6)+7.2(6) 4.8(6)+6.0(6)+7.2(6) 4.8(6)+7.2(6)+7.2(6) 6.0(6)+7.2(6)+7.2(6) 7.2(6)+7.2(6)+7.2(6)
Quantity - 2 3 3 3 3 3 3
Condenser Fan
Air Flow Rate m2/min 195+195 160+160+175 160+160+195 160+175+195 160+195+195 175+195+195 195+195+195
(Propeller Fan)
Motor Output (Pole) kW 0.66(8)+0.66(8) 0.40(8)+0.40(8)+0.52(8) 0.40(8)+0.40(8)+0.66(8) 0.40(8)+0.52(8)+0.66(8) 0.40(8)+0.66(8)+0.66(8) 0.52(8)+0.66(8)+0.66(8) 0.66(8)+0.66(8)+0.66(8)
Main Refrigerant Piping
Heat Pump System (2 Piping)
Liquid Line mm[in.] φ15.88[5/8] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4]
Gas Line Low Pressure mm[in.] φ28.58[1-1/8] φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ38.1[1-1/2]*
Main Refrigerant Piping
Heat Recovery System (3 Piping)
Liquid Line mm[in.] φ15.88[5/8] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4]
Gas Line Low Pressure mm[in.] φ28.58[1-1/8] φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ38.1[1-1/2]*
Gas Line High/Low Pressure mm[in.] φ25.4[1]* φ25.4[1]* φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8] φ28.58[1-1/8]
Refrigerant Charge kg 16.6 23.0 23.7 23.7 24.3 24.3 24.9
Packing Dimensions H×W×D mm - - - - - - -
Approx. Packing Measurement m2 - - - - - - -

NOTES:
1.The cooling and heating performances are the values when combined with our specified indoor units (Piping length : 7.5 Meters, Piping Lift : 0 Meter ).
(1) Cooling Operation Conditions : Indoor Air Inlet Temperature 26.7 oC DB / 19.4 oC WB, Outdoor Ambient Temperature 35 oC DB
(2) Cooling Operation Conditions : Indoor Air Inlet Temperature 29.0 oC DB / 19.0 oC WB, Outdoor Ambient Temperature 46 oC DB
(3) Cooling Operation Conditions : Indoor Air Inlet Temperature 26.6 oC DB / 19.4 oC WB, Outdoor Ambient Temperature 48 oC DB
(4) Heating Operation Conditions : Indoor Air Inlet Temperature 20 oC DB, Outdoor Air Inlet Temperature 7 oC DB / 6 oC WB
2. The sound pressure is based on the following conditions.
1Meter from the unit service cover surface, and 1.5 Meter from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1-2 dB.
The above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3.* If the specified main refrigerant piping on the table is not available on site, use the following pipe diameter with an appropriate reducer on site. If φ25.4 pipe is not available, please use φ28.58 pipe; If φ31.75
pipe is not available, please use φ34.92 pipe; If φ38.1 pipe is not available, please use φ41.28 pipe.
4. Except for the specified combination in the table (14-36HP), there is no other combination of the base unit.
5. The width of outer dimension, it is the value when each distance between the base outer units is specified to 20mm.

20
Indoor Units

Four-Way Cassette Type


Detecting Area
Example of 11.2kW and 16.0kW

Angle
Approx. 123˚

Dia. Approx. 7m (1.0~3.0FSN3)


Dia. Approx. 8.8m (4.0~6.0FSN3) Ceiling Height
3.2m

Motion Sensor Control (Option)


0.8m
The air conditioning capacity is saved automatically depending on a (From Floor Surface)

situation and detecting amount of human activity by adopting the In the case of the ceiling height is 3.2m.
motion sensor on the corner of the air panel. The energy saving can
be improved more with the individual operating function. In Adopting New Structured Silky Flow Louver
addition, the operation can be stopped automatically if the absent 75mm
The newly-structured silky flow
situation continues for more than 30 minutes*1. The motion sensor
louver is adopted to soften the
can maintain the comfortable indoor environment and eliminating
the unnecessary operation*2. discomfort by the temperature
irregularity and the cold draft.
*1): The default setting is “30 minutes”. However, the setting is changeable.
*2): The default setting is “Running Operation”. However, “Automatic Stop” can be selected by setting The individual control setting
*3): The detecting area becomes smaller if the people stay motion less is few such as stretching on a chair, etc. for each louver is available. New Silky Flow Louver

Specifications
Model JTKF028H0PS0AS JTKF040H0PS0AS JTKF056H0PS0AS JTKF071H0PS0AS JTKF080H0PS0AS JTKF112H0PS0AS JTKF140H0PS0AS JTKF160H0PS0AS
Indoor Unit Power Supply 1N~, 220-240V / 50Hz, 220V / 60Hz
kW 2.9 4.1 5.8 7.3 8.3 11.6 14.5 16.5
Nominal Cooling 2,500 3,550
kcal/h 5,000 6,300 7,100 10,000 12,500 14,200
Capacity *1) 9,900 14,100
Btu/h 19,800 25,000 28,200 39,700 49,600 56,300
kW 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Nominal Cooling kcal/h 2,400 3,400 4,800 6,100 6,900 9,600 12,000 13,800
Capacity *2) Btu/h 9,600 13,600 19,100 24,200 27,300 38,200 47,800 54,600
kW 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Nominal Heating
kcal/h 2,800 4,100 5,400 7,300 7,700 10,700 13,800 15,500
Capacity
Btu/h 10,900 16,400 21,500 29,000 30,700 42,600 54,600 61,400
Sound Pressure Level
dB 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37
(Overall A Scale) Hi2/Hi/Me/Lo

Dimensions H x W x D mm 248 x 840 x 840 298 x 840 x 840


Net Weight kg 20 21 22 26
Refrigerant R410A (Nitrogen-charged for Corrosion-resistance)
Air Flow Rate m3/min. 15/13/11/9 21/17/14/11 21/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22
Hi2/Hi/Me/Lo (cfm) (530/459/388/318) (741/600/494/388) (777/600/494/388) (953/812/635/494) (953/812/635/494) (1,306/1,094/847/706) (1,306/1,165/918/741) (1,306/1,236/988/777)
Motor W 57 127
Connections Flare-Nut Connection (With Flare Nuts)
Liquid / Gas mm φ6.35 /φ12.7 φ6.35 /φ15.88 φ9.52 /φ15.88
Condensate Drain VP25
Approximate
Packing Measurement m3 0.21 0.25

Adaptable Panel Model JP-AP160NA1 (without Motion Sensor) / JP-AP160NAE (with Motion Sensor)
Color Natural White
Dimensions H x W x D mm 37 x 950 x 950
Net Weight kg 6.5
Approximate
Packing Measurement m3 0.10

NOTES:
1. The nominal cooling and heating capacity is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

21
Indoor Units

Mini Four-Way
Cassette Type
New Design & High Specification Air Panel

530

Installation to Grid Ceiling


Low Noise (Top-class Sound Pressure Level)
570
This product can be installed to a

576
530
New developed high efficiency turbo-fan is adopted. By improving

570
grid ceiling with a 600mm x 600mm
3D twisted blade of turbo-fan and air outlet, the fan efficiency is
opening without cutting the grid.
improved and the low noise performance is achieved. 576
Grid Ceiling (mm)
NEW CURRENT
Indoor Unit Capacity (HP) Highly Compact Size
0.6 0.8 1.0 1.5 2.0 2.5 0.6 0.8 1.0 1.5 2.0 2.5
Compared with the standard Four-Way Cassette Type indoor unit,
Sound Pressure Level (dBA)
Air Flow Volume LOW
24.5 24.5 24.5 27.5 31 35 28 28 28 33 37 N/A the size of the air panel for this product has been reduced by
330mm (from 950mm to 620mm). 620mm

Light-weight Unit 620mm

Compared with the standard Four-Way Cassette Type indoor unit, the
570mm
weight of this product has been reduced by 4kg (from 21kg to 17kg).
This makes the transportation and installation much easier. 285mm

The dashed line shows the size of the standard Four-way cassette type.
Specifications
Model JTKM016H0PS0AS JTKM022H0PS0AS JTKM028H0PS0AS JTKM040H0PS0AS JTKM056H0PS0AS JTKM071H0PS0AS
Indoor Unit Power Supply 1N~, 220-240V / 50Hz, 220V / 60Hz
kW 1.7 2.3 2.9 4.1 5.8 7.3
Nominal Cooling
kcal/h 1,500 2,000 2,500 3,550 5,000 6,300
Capacity *1)
Btu/h 5,800 7,900 9,900 14,100 19,800 25,000
kW 1.6 2.2 2.8 4.0 5.6 7.1
Nominal Cooling
kcal/h 1,400 1,900 2,400 3,400 4,800 6,100
Capacity *2)
Btu/h 5,500 7,500 9,600 13,600 19,100 24,200
kW 1.9 2.5 3.2 4.8 6.3 8.5
Nominal Heating kcal/h 1,700 2,100 2,800 4,100 5,400 7,300
Capacity 6,500 8,500 10,900 16,400 21,500 29,000
Btu/h
Sound Pressure Level
(Overall A Scale) Hi2/Hi/Me/Lo
dB 34/30/28/24.5 36/33/29/24.5 38/34/30/24.5 41/37/33/27.5 45/39/35/31 47/43/39/35

Dimensions H x W x D mm 285 x 570 x 570


Net Weight kg 16 17
Refrigerant R410A (Nitrogen-charged for Corrosion-resistance)
Air Flow Rate 10/8.5/7.5/6 11/9.5/8/6 12/10/8.5/6 13/11/9.5/7 15/12/10/8 16/14/12/10
Hi2/Hi/Me/Lo m3/min.(cfm) (353/300/265/212) (388/335/282/212) (424/353/300/212) (459/388/335/247) (530/424/353/282) (565/494/424/353)
Motor W 57
Connections Flare-Nut Connection (With Flare Nuts)
Liquid / Gas mm φ6.35 /φ12.7 φ9.52 /φ15.88
Condensate Drain VP25
Approximate Packing Measurement m3 0.13
Adaptable Panel Model JP-AP56NAM
Color Neutral White
Dimensions H x W x D mm 30 x 620 x 620
Net Weight kg 2.5
Approximate Packing Measurement m3 0.04
NOTES:
1. The nominal cooling and heating capacity is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

22
Indoor Units

Two-Way Cassette Type


Improvement of Drain Pump
High-lift DC drain pump makes it possible to raise the drain pipe
straight up, up to 850mm from the false ceiling surface.

New Design & High Performance Air Panel 2-way Individual Louver Up

Simple & Stylish Design Adjustable the angle of


2 louvers individually by
Brand new design air panel. Simple stylish design yet applicable
newly equipped individual
for air inlet flat grill. Can be used as shutter at time of OFF the
louver setting function.
operation. Swing

Specifications
Model JTKT022H0PS0AS JTKT028H0PS0AS JTKT040H0PS0AS JTKT056H0PS0AS JTKT071H0PS0AS JTKT080H0PS0AS JTKT112H0PS0AS JTKT140H0PS0AS JTKT160H0PS0AS
Indoor Unit Power Supply 1N~, 220-240V / 50Hz, 220V / 60Hz
kW 2.3 2.9 4.1 5.8 7.3 8.3 11.6 14.5 16.5
Nominal Cooling kcal/h 2,000 2,500 3,550 5,000 6,300 7,100 10,000 12,500 14,200
Capacity *1) 7,900 9,900 14,100 19,800 25,000 28,200 39,700 49,600 56,300
Btu/h
kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Nominal Cooling kcal/h 1,900 2,400 3,400 4,800 6,100 6,900 9,600 12,000 13,800
Capacity *2) 7,500 9,600 13,600 19,100 24,200 27,300 38,200 47,800 54,600
Btu/h
kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Nominal Heating 4,100 5,400 7,300 7,700 10,700 13,800 15,500
kcal/h 2,100 2,800
Capacity 16,400 21,500 29,000 30,700 42,600 54,600 61,400
Btu/h 8,500 10,900
Sound Pressure Level
(Overall A Scale) Hi2/Hi/Me/Lo
dB 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39

Dimensions H x W x D mm 298 x 860 x 630 298 x 1,420 x 630


Net Weight kg 23 25 39
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Air Flow Rate m3/min. 10/9/7.5/6.5 11/9.5/8.5/7 15/13/11.5/10 16.5/14.5/12.5/10.5 18.5/16.5/14.5/12.5 21/18.5/16/12.5 30/26.5/23/20 35/31/27/21 37/32.5/28.5/24
Hi2/Hi/Me/Lo (cfm) (353/318/265/230) (388/335/300/247) (530/459/406/353) (583/512/441/371) (653/583/512/441) (742/653/565/441) (1,059/936/812/706) (1,236/1,095/953/742) (1,306/1,148/1,006/847)
Motor W 57 57 x 2
Connections Flare-Nut Connection (With Flare Nuts)
Liquid / Gas mm φ6.35 /φ12.7 φ9.52 /φ15.88
Condensate Drain VP25
Approximate
Packing Measurement m3 0.24 0.36

Adaptable Panel Model JP-AP90DNA JP-AP160DNA


Color Neutral White
Dimensions H x W x D mm 30 x 1,100 x 710 30 x 1,660 x 710
Net Weight kg 7.5 10.5
Approximate
Packing Measurement m3 0.13 0.20

NOTES:
1. The nominal cooling and heating capacity is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

23
Indoor Units

Ducted Type
(Medium and High Static)
Broader range of external static pressure. Flexibly supports a
wide range of installation conditions at site, e.g. longer ducts
In addition to the standard Hi-Me-Lo, the speed-up tap can be set by
remote control. Available for external static pressure of up to 80 Pa
for 2.2-7.1kW and 170 Pa for 8.4-14.2kW.

Space-saving Design 8.4kW model downsized


Less than 270 mm in height, this unit can be fit into practically any The width is 250mm Slimmer and the weight 9kg lighter than the
previously existing false ceiling or formerly ducted space without current model, thus delivery and installation is easier.
substantial modification (2.2-7.1kW).
Current Model New Model 9kg
Minimum 5mm Less
Weight 46kg Weight 37kg

270mm 250mm
False Ceiling
(2.2-7.1kW) Slimmer
900mm 650mm

Specifications
* *
Model JTDM022H0PS0AS JTDM028H0PS0AS JTDM040H0PS0AS JTDM056H0NS0AS JTDM071H0NS0AS JTDH080H0NS0AS JTDH112H0NS0AS JTDH140H0NS0AS JTDH224H0PS0AS JTDH280H0PS0AS
AC 1φ, 220-240V / 50Hz,
Indoor Unit Power Supply 1N, 220-240V / 50Hz, 220V / 60Hz
220V / 60Hz
kW 2.3 2.9 4.1 5.8 7.3 8.3 11.6 14.5 23.3 29.1
Nominal Cooling
kcal/h 2,000 2,500 3,550 5,000 6,300 7,100 10,000 12,500 20,000 25,000
Capacity *1)
Btu/h 7,900 9,900 14,100 19,800 25,000 28,200 39,700 49,600 79,400 99,200
kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 22.4 28.0
Nominal Cooling
kcal/h 1,900 2,400 3,400 4,800 6,100 6,900 9,600 12,000 19,300 24,100
Capacity *2)
Btu/h 7,500 9,600 13,600 19,100 24,200 27,300 38,200 47,800 76,400 95,500
kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 25.0 31.5
Nominal Heating
kcal/h 2,100 2,800 4,100 5,400 7,300 7,700 10,700 13,800 21,500 27,100
Capacity
Btu/h 8,500 10,900 16,400 21,500 29,000 30,700 42,600 54,600 85,300 107,500
Sound Pressure Level Hi/Me/Lo dB 35/33/31 36/34/32 42/39/35 43/40/36 44/41/37 - -
(Overall A Scale)
Hi2/Hi/Me/Lo dB - - - - - 45/43/40/36 50/48/46/39
Dimensions
mm
270 x (650+75) 270 x (900+75) 350 x (650+75) 350 x (900+75) 350 x (1,300+75)
HxWxD x 720 x 720 x 800 x 800 x 800 470 x 1,380x 1,060
Net Weight kg 26 35 37 46 58 94
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Air Flow Rate m3/min. 8/7/6 13/11/9 15/13/11 16/14/12 19/17/14 27/23/19 37/31/25
(cfm) (283/247/212) (459/388/318) (530/459/388) (565/494/424) (671/600/494) (954/812/671) (1,306/1,095/883) - -
Hi/Me/Lo

Hi2/Hi/Me/Lo m /min.
3
- - 63/58/50/38 80/72/64/48
(cfm) (2,224/2,048/1,765/1,341) (2,825/2,542/2,260/1,695)
External Pressure 50 (80-30)*3) 120 (170-60)*3) 50 (100-230)
Motor W 60 75 150 290 840 840
Connections Flare-Nut Connection (With Flare Nuts) Brazing Connection
Liquid mm φ6.35 φ6.35 φ9.52 φ9.52 φ9.52 φ9.52
Gas mm φ12.7 φ15.88 φ15.88 φ15.88*5) φ19.05 φ22.2
Condensate Drain VP25
Approximate
m3 0.21 0.27 0.29 0.38 0.52 0.97 0.97
Packing Measurement

NOTES: * Coming Soon


1. The nominal cooling and heating capacity is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1.5 Meter Beneath the Unit. With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1 or 2dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure *3) indicates "Standard Pressure Setting ( High Pressure Setting - Low Pressure Setting )" values when a filter is not used. Please consider pressure deduction
10Pa in case of York filter accessory used on the unit.

24
Indoor Units

Ducted Type (Low Static)


Flexibly Satisfy Varied Requests on Installation
Fire-proof Canvas Duct

Air Outlet
Double Layer Removable
Louver Air Outlet
Ceiling
Service Access Panel Single Layer Removable
Louver Air Inlet
Installation Diagram with Air Filter

Space-saving Design
When bottom air inlet is adopted,sound pressure will increase according
Less than 270 mm in height, this unit can be fit into practically any to factors such as installation mode and the room structure.
previously existing false ceiling or formerly ducted space without
substantial modification (2.2-7.1kW).

Minimum 5mm

270mm
False Ceiling
(2.2-7.1kW)

Specifications
Model JTDL022H0NP0AQ JTDL028H0NP0AQ JTDL036H0NP0AQ JTDL043H0NP0AQ JTDL050H0NP0AQ JTDL056H0NP0AQ JTDL063H0NP0AQ JTDL071H0NP0AQ

Indoor Unit Power Supply 1N~, 220-240V/50Hz

Model JTDL022H0NB0AQ JTDL028H0NB0AQ JTDL036H0NB0AQ JTDL043H0NB0AQ JTDL050H0NB0AQ JTDL056H0NB0AQ JTDL063H0NB0AQ JTDL071H0NB0AQ

Indoor Unit Power Supply 1N~, 220V/60Hz

kW 2.3 2.9 3.8 4.4 5.2 5.8 6.5 7.3


Nominal Cooling
kcal/h 2,000 2,500 3,300 3,800 4,500 5,000 5,600 6,100
Capacity*1)
Btu/h 7,800 9,900 13,000 15,100 17,700 19,800 22,200 25,000
kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1
Nominal Cooling
kcal/h 1,900 2,400 3,100 3,700 4,300 4,800 5,400 6,100
Capacity*2)
Btu/h 7,500 9,500 12,300 14,700 17,000 19,800 21,500 24,200
kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 8.5
Nominal Heating
kcal/h 2,400 2,800 3,600 4,200 4,800 5,600 6,500 7,300
Capacity
Btu/h 9,600 11,100 14,300 16,700 19,100 22,200 25,600 29,000
Sound Pressure Level
dB (A) 29.5-26-24.5 29.5-26-24.5 34-32-30 34-32-30 34-32-30 34-32-30 35-33-31 35-33-31
(High/Medium/Low)
Outer Dimensions
mm 270×(650+75)×720 270×(900+75)×720
H×W×D
Net Weight kg 26 26 26 26 35 35 35 35

Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)


Indoor Fan
Air Flow Rate m3/min. 8/7/6 8/7/6 13/11/9 13/11/9 15/13/11 15/13/11 16/14/12 16/14/12
(Hi/Me/Lo)
External Pressure *3) pa 30 30 30 30 30 30 30 30

Motor W 20 20 40 40 45 45 45 45
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53

Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88

Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25

Approximate
m3 0.21 0.21 0.21 0.21 0.27 0.27 0.27 0.27
Packing Measurement

25
Model JTDL084H0NP0AQ JTDL090H0NP0AQ JTDL112H0NP0AQ JTDL142H0NP0AQ JTDL160H0NP0AQ

Indoor Unit Power Supply 1N~,220-240V/50Hz

Model JTDL084H0NB0AQ JTDL090H0NB0AQ JTDL112H0NB0AQ JTDL142H0NB0AQ JTDL160H0NB0AQ

Indoor Unit Power Supply 1N~,220V/60Hz

kW 8.7 9.3 11.6 14.5 16.5


Nominal Cooling
kcal/h 7,500 8,000 10,000 12,500 14,200
Capacity*1)
Btu/h 29,700 31,700 39,700 49,500 56,300

kW 8.4 9.0 12.6 14.2 16.0


Nominal Cooling
kcal/h 7,200 7,700 9,600 12,200 13,800
Capacity*2)
Btu/h 28,700 30,700 38,000 48,400 54,600
kW 9.6 10.0 13.0 16.3 18.0
Nominal Heating
kcal/h 8,300 8,600 11,200 14,000 15,500
Capacity
Btu/h 32,800 34,100 44,400 55,500 61,400
Sound Pressure Level
dB (A) 40-37-33 40-37-33 41.5-39-35 42-39-35 43-39-37
(High/Medium/Low)
Outer Dimensions
mm 350×(900+75)×800 350×(900+75)×800 350×(900+75)×800 350×(1,300+75)×800 350×(1,300+75)×800
H×W×D

Net Weight kg 46 46 46 58 58

Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)

Indoor Fan
Air Flow Rate m3/min. 25/21/17 25/21/17 27/23/19 37/31/25 38/35/29
(Hi/Me/Lo)

External Pressure *3) pa 60 60 60 60 60

Motor W 100 100 100 160 180

Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53

Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88

Condensate Drain VP25 VP25 VP25 VP25 VP25

Approximate
m3 0.38 0.38 0.38 0.52 0.52
Packing Measurement

NOTES:
1. The nominal cooling capacity is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27°C DB (80°F DB)
*1) 19.5°C WB (67°F WB)
*2) 19.0°C WB (66.2°F WB)
Outdoor Ambient Temperature: 35°C DB (95°F DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20°C DB (68°F DB)
Outdoor Ambient Temperature: 7°C DB (45°F DB)
6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
3. The data for external pressure *3) indicates” Standard Pressure Setting values when a filter is not used. Please consider pressure deduction 10Pa in case of York filter accessory used on the unit.

26
Indoor Units

Ducted Type
(Medium and High Static)
Flexibly Satisfy Varied Requests on Installation
Fire-proof Canvas Duct

Air Outlet
Double Layer Removable
Louver Air Outlet
Ceiling
Service Access Panel Single Layer Removable
Space-saving Design Installation Diagram
Louver Air Inlet
with Air Filter

Less than 270 mm in height, this unit can be fit into practically any
When bottom air inlet is adopted,sound pressure will increase according
previously existing false ceiling or formerly ducted space without to factors such as installation mode and the room structure.
substantial modification (2.2-7.1kW).

Minimum 5mm

270mm
False Ceiling
(2.2-7.1kW)

Specifications (Medium Static)


Model JTDM022H0NP0AQ JTDM028H0NP0AQ JTDM036H0NP0AQ JTDM043H0NP0AQ JTDM050H0NP0AQ
Indoor Unit Power Supply 1N~, 220-240V/50Hz
Model JTDM022H0NB0AQ JTDM028H0NB0AQ JTDM036H0NB0AQ JTDM043H0NB0AQ JTDM050H0NB0AQ
Indoor Unit Power Supply 1N~, 220V/60Hz
kW 2.3 2.9 3.8 4.4 5.2
Nominal Cooling Capacity*1) kcal/h 2,000 2,500 3,300 3,800 4,500
Btu/h 7,800 9,900 13,000 15,100 17,700
kW 2.2 2.8 3.6 4.3 5.0
Nominal Cooling Capacity*2) kcal/h 1,900 2,400 3,100 3,700 4,300
Btu/h 7,500 9,500 12,300 14,700 17,000
kW 2.8 3.3 4.2 4.9 5.6
Nominal Heating
kcal/h 2,400 2,800 3,600 4,200 4,800
Capacity
Btu/h 9,600 11,100 14,300 16,700 19,100
Sound Pressure Level
dB (A) 35-33-31 35-33-31 35-33-31 35-33-31 35-33-31
(High/Medium/Low)
Outer Dimensions
mm 270×(650+75)×720 270×(900+75)×720
H×W×D
Net Weight kg 26 26 26 26 35
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/min 8/7/6 8/7/6 13/11/9 13/11/9 15/13/11
(Hi/Me/Lo)
External Pressure (Option) *3) pa 50(80) 50(80) 50(80) 50(80) 50(80)
Motor W 35 35 60 60 75
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25
Approximate
m3 0.21 0.21 0.21 0.21 0.27
Packing Measurement

27
Specifications (Medium)
Model JTDM056H0NP0AQ JTDM063H0NP0AQ JTDM071H0NP0AQ JTDM224H0NM0AQ JTDM280H0NM0AQ
Indoor Unit Power Supply 1N~,220-240V/50Hz 3N~,380-415V/50Hz
Model JTDM056H0NB0AQ JTDM063H0NB0AQ JTDM071H0NB0AQ JTDM224H0NF0AQ JTDM280H0NF0AQ
Indoor Unit Power Supply 1N~,220V/60Hz 3N~,380V/60Hz
kW 5.8 6.5 7.3 23.2 28.6
Nominal Cooling Capacity*1) kcal/h 5,000 5,600 6,300 20,000 24,600
Btu/h 19,800 22,200 25,000 79,200 97,600
kW 5.6 6.3 7.1 22.4 28.0
Nominal Cooling Capacity*2) kcal/h 4,800 5,400 6,100 19,300 24,100
Btu/h 19,100 21,500 24,200 76,500 95,600
kW 6.5 7.5 8.5 25.0 31.5
Nominal Heating
kcal/h 5,600 6,500 7,300 21,500 27,100
Capacity
Btu/h 22,200 25,600 29,000 85,300 107,500
Sound Pressure Level
dB (A) 35-33-31 36-34-32 36-34-32 50 52
(High/Medium/Low)
Outer Dimensions
mm 270×(900+75)×720 470×1,060×1,120 470×1,250×1,120
H×W×D
Net Weight kg 35 35 35 96 104
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/min 15/13/11 16/14/12 16/14/12 58 72
(Hi/Me/Lo)
External Pressure (Option) *3) pa 50(80) 50(80) 50(80) 100 100
Motor W 75 75 75 500 750
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ9.53 Φ9.53 Φ9.53 Φ9.53
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
Condensate Drain VP25 VP25 VP25 VP25 VP25
Approximate
m3 0.27 0.27 0.27 0.9 0.9
Packing Measurement

Specifications (High Static)


Model JTDH084H0NP0AQ JTDH090H0NP0AQ JTDH112H0NP0AQ JTDH142H0NP0AQ JTDH160H0NP0AQ JTDH224H0NM0AQ JTDH280H0NM0AQ
Indoor Unit Power Supply 1N~,220-240V/50Hz 3N~,380-415V/50Hz
Model JTDH084H0NB0AQ JTDH090H0NB0AQ JTDH112H0NB0AQ JTDH142H0NB0AQ JTDH160H0NB0AQ JTDH224H0NF0AQ JTDH280H0NF0AQ
Indoor Unit Power Supply 1N~,220V/60Hz 3N~,380V/60Hz
kW 8.7 9.3 11.6 14.5 16.5 23.2 28.6
Nominal Cooling Capacity*1) kcal/h 7,500 8,000 10,000 12,500 14,200 20,000 24,600
Btu/h 29,700 31,700 39,700 49,500 56,300 79,800 97,600
kW 8.4 9.0 11.2 14.2 16.0 22.4 28.0
Nominal Cooling Capacity*2) kcal/h 7,200 7,700 9,600 12,200 13,800 19,300 24,100
Btu/h 28,700 30,700 38,000 48,400 54,600 76,500 95,600
kW 9.6 10.0 13.0 16.3 18.0 25.0 31.5
Nominal Heating
kcal/h 8,300 8,600 11,200 14,000 15,500 21,500 27,000
Capacity
Btu/h 32,800 34,100 44,400 55,500 61,400 85,300 107,000
Sound Pressure Level
dB (A) 42-39-35 42-39-35 43-40-36 44-41-37 45-41-37 50 52
(High/Medium/Low)
Outer Dimensions
mm 350×(900+75)×800 350×(1,300+75)×800 470×1,060×1,120 470×1,250×1,120
H×W×D
Net Weight kg 46 46 46 58 58 96 104
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Air Flow Rate m3/min 25/21/17 25/21/17 27/23/19 37/31/25 38/35/29 58 72
(Hi/Me/Lo)
External Pressure (Option) *3) pa 120(90) 120(90) 120(90) 120(90) 120(90) 180 180
Motor W 120 120 120 200 280 650 900
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate
m3 0.38 0.38 0.38 0.52 0.52 0.9 1.06
Packing Measurement
NOTES:
1. The nominal cooling capacity is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27°C DB (80°F DB)
*1) 19.5°C WB (67°F WB)
*2) 19.0°C WB (66.2°F WB)
Outdoor Ambient Temperature: 35°C DB (95°F DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20°C DB (68°F DB)
Outdoor Ambient Temperature: 7°C DB (45°F DB)
6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
3. The data for external pressure *3) indicates” Standard Pressure Setting values when a filter is not used. Please consider pressure deduction 10Pa in case of York filter accessory used on the unit.

28
Indoor Units

Ducted Type (Slim)


Flexibly Satisfy Varied Requests on Installation
Fire-proof Canvas Duct

Air Outlet
Double Layer Removable
Louver Air Outlet
Ceiling
Service Access Panel Single Layer Removable
Louver Air Inlet
Installation Diagram with Air Filter

Installation Space-saving
With a width of 700mm may be easily installed inside narrow When bottom air inlet is adopted,sound pressure will increase
residential ceiling. according to factors such as installation mode and the room
Minimum 5mm structure.

10Pa(or30pa), flexibly supports a wide range of installation


700mm conditions at site, e.g. longer ducts and shorter ducts supplied.
False Ceiling

Specifications
Model JTDS022H0PP0AQ JTDS028H0PP0AQ JTDS036H0PP0AQ JTDS043H0PP0AQ
Power Supply 1N~, 220-240V/50Hz
Model JTDS022H0PB0AQ JTDS028H0PB0AQ JTDS036H0PB0AQ JTDS043H0PB0AQ
Power Supply 1N~,220V/60Hz
KW 2.3 2.9 3.8 4.4
Nominal Cooling Capacity *1 kcal/h 2,000 2,500 3,300 3,800
Btu/h 7,800 9,900 13,000 15,000
kW 2.2 2.8 3.6 4.3
Nominal Cooling Capacity *2 kcal/h 1,900 2,400 3,100 3,700
Btu/h 7,500 9,500 12,300 14,700
kW 2.8 3.3 4.2 4.9
Nominal Heating Capacity kcal/h 2,400 2,800 3,600 4,200
Btu/h 9,600 11,100 14,300 16,700
Sound Pressure Level
dB(A) 28-25-22 28-25-22 32-30-28 32-30-28
(High/Medium/Low)
Outer Dimensions
mm 192×700×602 192×700×602 192×700×602 192×700×602
H×W×D
Net Weight kg 21 21 22 22
Refrigerant R410A (Nitrogen-charged for Corrosion-resistance)
Indoor Fan Air Flow Rate
m3/min 8/7/6 8/7/6 10/8/7 10/8/7
(High /Medium /Low)
Motor Power w 50 50 60 60
Connections Refrigerant Piping Flare-nut Connection (with Flare Nuts)
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7
Condensate Drain VP25
External Static Pressure Pa 10(30) 10(30) 10(30) 10(30)
Approximate Packing Measurement m3 0.15 0.15 0.15 0.15

NOTES: 2. The sound pressure level is based on following conditions.


1. The nominal cooling capacity is based on the JIS standard B8616. 1.5 Meter Beneath the Unit.
Cooling Operation Conditions With Discharge Duct (2.0m) and Return Duct (1.0m).
Indoor Air Inlet Temperature: 27°C DB (80°F DB) Voltage of the power source for the indoor fan motor is 220V.
*1) 19.5°C WB (67°F WB) In case of the power source of 240V, the sound pressure level increases by about 1 dB.
*2) 19.0°C WB (66.2°F WB) The above data was measured in an anechoic chamber so that reflected should be taken
Outdoor Ambient Temperature: 35°C DB (95°F DB) into consideration in the field.
Heating Operation Conditions 3. The data for external pressure *3) indicates” Standard Pressure Setting values when a
Indoor Air Inlet Temperature: 20°C DB (68°F DB) filter is not used. Please consider pressure deduction 10Pa in case of York filter
Outdoor Ambient Temperature: 7°C DB (45°F DB) accessory used on the unit.
6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter

29
Indoor Units

Ducted Type (Compact)


Flexibly Satisfy Varied Requests on Installation
Fire-proof Canvas Duct

Air Outlet
Double Layer Removable
Louver Air Outlet
Ceiling
Service Access Panel Single Layer Removable
Louver Air Inlet
Installation Diagram with Air Filter

Installation Space-saving
When bottom air inlet is adopted,sound pressure will increase according
to factors such as installation mode and the room structure.

Specifications
Model JTDN022H0PP0AQ JTDN028H0PP0AQ JTDN036H0PP0AQ JTDN043H0PP0AQ JTDN050H0PP0AQ JTDN056H0PP0AQ JTDN063H0PP0AQ JTDN071H0PP0AQ
Indoor Unit Power Supply 1N~,220-240V/50Hz
Model JTDN022H0PB0AQ JTDN028H0PB0AQ JTDN036H0PB0AQ JTDN043H0PB0AQ JTDN050H0PB0AQ JTDN056H0PB0AQ JTDN063H0PB0AQ JTDN071H0PB0AQ
Indoor Unit Power Supply 1N~,220V/60Hz
kW 2.3 2.9 3.8 4.4 5.2 5.8 6.5 7.3
Nominal Cooling Capacity*1) kcal/h 2,000 2,500 3,300 3,800 4,500 5,000 5,600 6,300
Btu/h 7,800 9,900 13,000 15,100 17,700 19,800 22,200 25,000
kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1
Nominal Cooling Capacity*2) kcal/h 1,900 2,400 3,100 3,700 4,300 4,800 5,400 6,100
Btu/h 7,500 9,500 12,300 14,700 17,100 19,100 21,500 24,200
kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 8.5
Nominal Heating Capacity kcal/h 2,400 2,800 3,600 4,200 4,800 5,600 6,500 7,300
Btu/h 9,600 11,100 14,300 16,700 19,100 22,200 25,600 29,000
Sound Pressure Level
dB (A) 27-24-21 27-24-21 31-29-26 31-29-26 34-30-28 34-30-28 35-33-30 35-33-30
(High/Medium/Low)
Outer Dimensions
mm 192×900×447 192×1,170×447 192×1,170×447
H×W×D
Net Weight kg 20 20 21 21 26 26 26 26
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan Air Flow Rate
m3/min 8/7/6 8/7/6 10/8/7 10/8/7 14.5/12.5/10.5 14.5/12.5/10.5 16/14/12 16/14/12
(Hi/Me/Lo)
External Pressure (Option) *3) pa 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30)
Motor W 16 16 25 25 40 40 50 50
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53
Ges Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25
Approximate Packing
m 3
0.15 0.15 0.15 0.15 0.18 0.18 0.18 0.18
Measurement
NOTES:
1. The nominal cooling capacity is based on the JIS standard B8616. 2. The sound pressure level is based on following conditions.
Cooling Operation Conditions 1.5 Meter Beneath the Unit.
Indoor Air Inlet Temperature: 27°C DB (80°F DB) With Discharge Duct (2.0m) and Return Duct (1.0m).
*1) 19.5°C WB (67°F WB) Voltage of the power source for the indoor fan motor is 220V.
*2) 19.0°C WB (66.2°F WB) In case of the power source of 240V, the sound pressure level increases by about 1 dB.
Outdoor Ambient Temperature: 35°C DB (95°F DB) The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the
Heating Operation Conditions field.
Indoor Air Inlet Temperature: 20°C DB (68°F DB) 3. The data for external pressure *3) indicates” Standard Pressure Setting values when a filter is not used. Please
Outdoor Ambient Temperature: 7°C DB (45°F DB) consider pressure deduction 10Pa in case of York filter accessory used on the unit.
6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter

30
Indoor Units

Ceiling Suspended Type


High Efficiency and Low Noise by New Fan Runner
Newly-developed fan runner is adopted. By improving shapes of
fin and air outlet, the fan efficiency is improved and the low noise
performance is achieved.

Fan Casing
Air Outlet
Diffuser
New L-Shaped Fin

Specifications
Model JTCS040H0NS0AS JTCS056H0NS0AS JTCS071H0NS0AS JTCS080H0NS0AS JTCS112H0NS0AS JTCS140H0NS0AS JTCS160H0NS0AS
Indoor Unit Power Supply 1N~, 220-240V / 50Hz, 220V / 60Hz
kW 4.1 5.8 7.3 8.3 11.6 14.5 16.5
Nominal Cooling
kcal/h 3,550 5,000 6,300 7,100 10,000 12,500 14,200
Capacity *1)
Btu/h 14,100 19,800 25,000 28,200 39,700 49,600 56,300
kW 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Nominal Cooling
kcal/h 3,400 4,800 6,100 6,900 9,600 12,000 13,800
Capacity *2)
Btu/h 13,600 19,100 24,200 27,300 38,200 47,800 54,600
kW 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Nominal Heating
kcal/h 4,100 5,400 7,300 7,700 10,700 13,800 15,500
Capacity
Btu/h 16,400 21,500 29,000 30,700 42,600 54,600 61,400

Sound Pressure Level


dB 37/35/31/28 38/35/31/28 38/35/32/29 40/37/33/29 44/42/37/32 48/45/41/35 49/47/42/36
(Overall A Scale) Hi2/Hi/Me/Lo

Cabinet Color Neutral White


Dimensions H x W x D mm 235 x 960 x 690 235 x 1,270 x 690 235 x 1,580 x 690
Net Weight kg 26 27 35 41
Refrigerant R410A
Air Flow Rate m3/min. 15/13/11/9 19/16.5/14/11.5 21/18.5/15.5/12.5 30/26.5/22/17 35/31/25.5/20 37/32.5/27/21
Hi2/Hi/Me/Lo (cfm) (530/459/388/318) (671/583/494/406) (742/653/547/441) (1,059/936/777/600) (1,236/1,095/900/706) (1,306/1,148/953/742)
Motor W 50 80 160
Connections Flare-Nut Connection (With Flare Nuts)
Liquid / Gas mm φ6.35 /φ12.7 φ6.35 /φ15.88 φ9.52 /φ15.88 φ9.52 /φ15.88
Condensate Drain VP20
Approximate m3 0.23 0.31 0.38
Packing Measurement
NOTES:
1. The nominal cooling and heating capacity is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1 Meter Beneath the Unit and 1 Meter from Discharge Grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

31
Indoor Units

High Wall Type


User Friendly
Easy switching from wireless to wired remote controller by Dip
Switch built-in the receiver part. All alarm code is displayed when
using wireless remote controller by combining the flashing times of
"Timer", "Filter/Defrosting". (All models)

Expansion Valve Kit (Option)


Reducing Noise by Adopting Distinctive Technology
φ6.35mm
You can select the new lineup of indoor unit wall type without Wall Type Indoor Unit
For the combination with VRF series
(JTHW028HONSOBM)
expansion valve and electronic expansion valve kit according to your outdoor units, when the piping length between
multi-kit and indoor unit exceeds 15m,
preference. The continuous refrigerant running noise from the indoor φ9.52mm shall be used.
unit can be reduced by installing the expansion valve away from the
living room such as in a false ceiling of the hallway.

Expansion Valve Kit


Refrigerant Liqud Piping: φ6.35mm
(JEV-1.5N1)
(Current Model: φ9.52mm)

Specifications
Model JTHW016H0NS0AM JTHW022H0NS0AM JTHW028H0NS0AM JTHW040H0NS0AM
JTHW056H0NS0AM JTHW071H0NS0AM JTHW080H0NS0AM JTHW112H0NS0AM
JTHW016H0NS0BM*3) JTHW022H0NS0BM*3) JTHW028H0NS0BM*3) JTHW040H0NS0BM*3)
Indoor Unit Power Supply 1N~, 220-240V / 50Hz, 220V / 60Hz
kW 1.8 2.3 2.9 4.1 5.8 7.3 8.3 11.6
Nominal Cooling
kcal/h 1,600 2,000 2,500 3,550 5,000 6,300 7,100 10,000
Capacity *1)
Btu/h 6,100 7,900 9,900 14,100 19,800 25,000 28,200 39,700
kW 1.7 2.2 2.8 4.0 5.6 7.1 8.0 11.2
Nominal Cooling
kcal/h 1,500 1,900 2,400 3,400 4,800 6,100 6,900 9,600
Capacity *2)
Btu/h 5,800 7,500 9,600 13,600 19,100 24,200 27,300 38,200
kW 1.9 2.5 3.2 4.8 6.3 8.5 9.0 12.5
Nominal Heating
kcal/h 1,700 2,100 2,800 4,100 5,400 7,300 7,700 10,700
Capacity
Btu/h 6,500 8,500 10,900 16,400 21,500 29,000 30,700 42,600
Sound Pressure Level
dB 35/32/31/29 39/35/32/30 39/35/32/30 46/40/36/33 42/40/38/33 49/43/40/36 51/49/46/41
(Overall A Scale) Hi2/Hi/Me/Lo

Cabinet Color White


Dimensions H x W x D mm 300 x 790 x 230 300 x 790 x 230 300 x 790 x 230 300 x 900 x 230 333 x 1,150 x 245
Net Weight kg 10 10 10 11 17 18
Refrigerant R410A
Air Flow Rate m3/min. 8/7.5/7/6.0 10/8/7/6.5 14/11/9/7.5 15/14/13/10 19/17/14/12 22/19/17/15
Hi2/Hi/Me/Lo (cfm) (282/265/247/212) (353/282/247/230) (494/388/318/265) (530/494/459/353) (671/600/494/424) (777/671/600/530)
Motor W 40
Connections Flare-Nut Connection (With Flare Nuts)
Liquid / Gas mm φ6.35 /φ12.7 φ6.35 /φ15.88 φ9.52 /φ15.88
Condensate Drain VP16
Approximate m3 0.09 0.11 0.14
Packing Measurement
Standard Accessories Wall Mounting Bracket

NOTES:
1. The nominal cooling and heating capacity is based on the JIS standard B8616.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1 Meter Beneath the Unit and 1 Meter from Air Inlet Grille
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Dew condenstion water can be dropped out from air outlet under installation when some solid substances are intruded into a refrigerant pipe. Once the substances get inside of electric expansion
valve, the dew condensation occurred, because heat exchanger or fans get cooledwith subtle running in refrigerant. The dew condensation water can come out fromthe air oulet when its operation
started. Therefore, to prevent the intrusion of substances into electric expansion valve, it is strongly recommended to install Strainer Kit (optional part) into the refrigerant pipe nearby indoor unit.
*3) These models are the indoor unit without expansion valve. Expansion valve kit(JEV-1.5N1) should be used with the models

32
Optional Parts
Indoor Units
Four-Way Cassette Type YORK Ducted Type (For JTDH/M/L *********Q)
HP (kW) 1.0-6.0(2.8-16.0) HP(kW) 0.8 ~ 1.5(2.2~4.3) 1.8 ~ 2.5(5.0~7.1) 3.0 ~ 4.0(8.4~11.2) 5.0 ~ 6.0(14.2~16.0) 8.0 ~ 10.0(22.4~28.0)
Air Panel JP-AP160NA1/JP-AP160NAE (with motion sensor) Drain-up
DUPI-132CQ DUPI-162Q DUPI-15H2Q
Mechanism Kit
Long-Life Filter JKW-PP1Q JKW-PP2Q JKW-PP3Q JKW-PP4Q -

YORK Ducted Type (For JTDN *********Q)


HP(kW) 0.8 ~ 1.5(2.2~4.3) 1.8 ~ 2.5(5.0~7.1)
Long-Life Filter JKW-PP5Q JKW-PP6Q
Ducted Type (For JTDH/M *********S)

HP(kW) 0.8 ~ 1.5(2.2~4.3) 2.0 and 2.5(5.6 and 7.1) 3.0(8.4) 4.0(11.2) 5.0(14.2) 8 and 10(22.4 and 28.0)
Long-Life Filter Kit Long-Life Filter JF-15LI3C JF-23LI3C JF-23LI3 JF-34LI3 JF-46LI3 F-280LI*
Filter Box JB-15MI3C JB-23MI3C JB-23MI3 JB-34MI3 JB-46MI3 B-280LI*
Drain-up Mechanism Kit Standard DUPI-132C DUPI-162 -
* Coming Soon
Two-Way Cassette Type Ceiling Suspended Type
HP (kW) 0.8 ~ 3.0(2.2-8.4) 4.0 ~ 6.0(11.2-16.0) HP (kW) 1.5(4.3) 2.0(5.6) 2.5 to 6.0(7.1-16.0)
Air Panel JP-AP90DNA JP-AP160DNA Drain-up Mechanism JDUPC-63K1 JDUPC-71K1 JDUPC-160K1

Mini Four Way Cassette Type High Wall Type Receiver Kit for Wireless Control
HP (kW) 0.6 ~ 2.5(1.6-7.1) HP (kW) 0.6 ~ 1.5(1.6-4.3) JTKF JTKM JTKT JTCS JTDH/M/L/N/S JTHW
Air Panel JP-AP56NAM Electronic Model JR4A10NEWS JRMA10NEWS JR2A10NEWS JRCA10NEWS JRDA10NEWS JRDA11NEWS*2
JEV-1.5N1
Expansion Valve Kit *1
NOTES:
*1. The electronic expansion valve kit (optional part JEV-1.5N1) should be used with indoor unit high wall type
without expansion valve together.
*2. Wall mounted type

Piping Connection Kit Strainer Kit


Operation Type Applicable Outdoor Unit Product Name Model
Heat Pump Operation Heat Recovery Operation JUOD Series (HP) MSF-NP63A MSF-NP112A
Strainer Kit
JMC-NP20A1 JMC-NP20X1 16 to 24 MSF-NP36AH*1
JMC-NP30A1 JMC-NP30X1 26 to 36 NOTE:
*1. For without Expansion Valve indoor unit.

Multi-kits
Multi-kit for 2 Pipe Heat Pump Operation Multi-kit for 3 Pipe Heat Recovery Operation
< Line Branch > (First Branch) <Header Branch > < Line Branch > (First Branch) < Header Branch >
Outdoor Unit HP Model Total Outdoor Unit HP Model Total
No. of No. of
8 to 10 MW-NP282A3 Indoor Unit Model Indoor Unit Model
Header Branches 8 to 10 MW-NP282X3 Header Branches
HP(kW) HP(kW)
12 and 16 MW-NP452A3 12 and 16 MW-NP452X3
18 to 24 MW-NP692A3 5 to 8(14.2 to 22.4) 4 JMH-NP224A 5 to 10(14.2 to 28.0) 8 JMH-NP288X
18 and 20 MW-NP562X3
26 to 36 MW-NP902A3 5 to 10(14.2 to 28) 8 JMH-NP288A 22 and 24 MW-NP692X3
NOTE: After the second branch, please refer to the technical manual. 26 to 36 MW-NP902X3

Control System : Applicable : Not Applicable


JTKF JTKM JTKT JTDH/M/L/N/S JTCS JTHW
1
JCWA10NEWQ*
Remote Control Switch 1
JCWB10NEWS*
Wireless Remote Control Switch JCRB10NEWS
Half-size Remote Control Switch JCSA10NEWS
Central Station mini JCMA101EWS
Central Station EZ JCTA121EWS
Centralized ON/OFF Controller JCOA111EWS
Remote Control Cable PRC-5K, 10K, 15K
3P Connector Cable PCC-1A
Remote Sensor THM-R2A

NOTES: *1. As the JCWA10NEWQ and JCWB10NEWS does not include a remote control cable, prepare one in the field, or use PRC-5K, 10K, or 15K.

33
Remote Controllers
The LED-backlit LCD provides enhanced legibility.
Remote Control Switch
Large, clear character display is realized by Full Dot Matrix LCD.
JCWB10NEWS
Compatible with the H-LINKⅡ The directional key provides optimized operation.
The manual operation is facilitated by reducing number of switch buttons from 13 to 9.

“Schedule Timer” provides the timer operations for “Run/Stop” and “Temperature Setting”.
The weekly management is available by using this function. In addition “Holiday Setting” and
“Schedule ON/OFF”setting are available.

4 type of menus are offered for flexible use as follows:


Menu: Contains “Schedule”, “Screen Display Setting”, etc. for users.
Help Menu: Contains information provided by this remote control switch for users such as
“About Indication”, “Contact Information”, etc.
Test Run Menu: This menu provides the functions installation of this remote control switch.
Check Menu: This menu provides the functions for service and maintain

Remote Control Switch The LCD display permits users to see the operating conditions and settings.

JCWA10NEWQ The timer can be set at half-hour intervals up to 72 hours.


Compatible with the H-LINKⅡ All the functions can be selected by remote control switches.
JCWA10NEWQ monitors the operating conditions in the system and an alarm is issued if a
problem occurs.
A "self-diagnosis function" checks for problems on printed boards in indoor andoutdoor units.
Equipped with energy-saving functions such as a preset temperature range limiting function for
preventing excessive cooling/heating and a preset temperature automatic reset function, as well
as an operation locking mechanism and the capability to prevent users from forgetting to turn off
the system. (Function selection setting is required)

One-touch handy operation, no wiring work required.


Wireless
Remote Control Switch Two or more units can be operated simultaneously by remote control.

JCRB10NEWS * Receiver kit is required.


Compatible with the H-LINKⅡ

Half-size The main function of this easy-to-use remote control system is temperature setting.
Remote Control Switch Operation modes can be switched over (when function selection setting is made).
JCSA10NEWS Suitable for facilities used by various people, such as hotels.
Compatible with the H-LINKⅡ
"2 remote control" or "group control" (up to 16 max.) can be used.
If a problem occurs, an alarm code immediately shows the details of the problem.

Centralized Only performs operation/stop control per remote control group.


ON/OFF Controller By connecting to the H-LINK, up to 16 remote control groups and 160 indoor units can be controlled.
Up to 8 units can be connected to the H-LINK.
JCOA111EWS
Compatible with the H-LINKⅡ An external input terminal is provided as standard. External signals enable thefollowing functions:
・central operation/stop, emergency stop,
Up to 160 indoor units
・central operation output, central alarm output
Up to 16 remote control groups * Make sure to use it with a remote control switch. Indoor units cannot be used without a remote control switch.
* There are restrictions on remote group registration. Please contact our sales staff for more information.

34
Network Systems
CS-NET
The flexibility of the YORK VRF system allows the internal data to be easily accessed and controlled by the user,
with features including temperature, mode and fan speed setting and groupings.

*1
Building BACnet R

Management
System

LONWORKS R *2

Open Network
Systems

Central Centralized
JBAA101EWS Central Station EZ ON/OFFController
Station mini
Coming Soon

JLAA101EWS

JCTA121EWS JCMA101EWS JCOA111EWS

H-LINK*4 H-LINKⅡor H-LINKⅡor H-LINKⅡor


H-LINK H-LINK*1 H-LINK*1

Outdoor Units H-LINKⅡor


H-LINK*1

JUOD Series

Indoor Units

JTKT JTCS

JTKF JTHW
JTKM JTDH/M/L/N

Remote Controllers
*1: Though connection with H-LINKⅡ is available,
the resulting performance is equivalent to that
of the H-LINK specifications.

JCWB10NEWS JCWA10NEWQ JCRB10NEWS Receiver Kit JCSA10NEWS

35
Central Station
Specification
Central Station mini Communication Unit Units of Adopting for H-LINKⅡ

JCMA101EWS Communication Line Non-Polar 2-Wire


Communication Method Half-Duplex Communication
Synchro System Asynchronous (start-stop synchronous communication)
Communication Speed 9,600bps

120 Wiring Length 1,000m (Total Length)


mm
Outdoor Unit Indoor Unit Central Controller Total Unit Number
Connecting
H-LINKⅡ 64 160 8 200
Unit Number*
H-LINK 16 128 8 145

140mm
*: Connecting unit quantity indicates the maximum unit numbers which is possible to connect in the same H-LINK (Control Wiring).

Functions
Most compact in our touch panel centralized • Run/Stop/Abnormality • Operation Mode
controller. • Setting Temperature • Setting Fan Speed • Setting Louver
Its down-to-detail control functionalities, Monitor Function
• RCS Operation Prohibited Setting • Filter Sign • Alarm Code
such as Weekly Scheduling, Accumulated Work • Accumulated Operating Time
Hours, etc., help you save energy.
• Run/Stop* • Operation Mode • Temperature Setting
Up to 32 remote-controlled groups and up to Control Function
• Fan Speed • Louver • RCS Operation Prohibited • Filter Sign Reset
160 indoor units can be connected to the single
air-conditioning system. *: groups
“All Groups Run/Stop” command signal exception function for selected
is available by “Exception of Run/Stop Ope.” function.

Specification
Central Station EZ Communication Unit Units of Adopting for H-LINKⅡ
JCTA121EWS Communication Line Non-Polar 2-Wire
Communication Method Half-Duplex Communication
Synchro System Asynchronous (start-stop synchronous communication)
Communication Speed 9,600bps

170 Wiring Length 1,000m (Total Length)


mm
Outdoor Unit Indoor Unit Central Controller Total Unit Number
Connecting
H-LINKⅡ 64 160 8 200
Unit Number*
H-LINK 16 128 8 145
: Connecting unit quantity indicates the maximum unit numbers which is possible to connect in the same H-LINK (Control Wiring).
250mm *

Functions
Eazy control with 8.5 inch color touch panel • Run/Stop/Abnormality • Operation Mode
Its down-to-detail control functionalities, • Setting Temperature • Setting Fan Speed • Setting Louver
such as Weekly Scheduling, Accumulated Work Monitor Function
• RCS Operation Prohibited Setting • Filter Sign • Alarm Code
Hours, etc., help you save energy. • Accumulated Operating Time
Up to 64 remote-controlled groups and up to
• Run/Stop* • Operation Mode • Temperature Setting
160 indoor units can be connected to the single Control Function
• Fan Speed • Louver • RCS Operation Prohibited • Filter Sign Reset
air-conditioning system.
: “All Groups Run/Stop” command signal exception function for selected
* groups is available by “Exception of Run/Stop Ope.” function.

36
Network Systems
Interface
You can select the air conditioner control interface depending on your needs to create a comfortable space.

Connection Method to
JBAA101EWS (for BACnet ) • BACnet / IP by IEEE802.3 Compliance (100BASE-TX/10BASE-T)
R

Upper System
Coming Soon
Quantity of Connection • Up to 64 Indoor Units per BACnet Adaptor
R

• RUN/STOP • Available / Not Available for Operation by


Control Item at • Operation Mode Setting Remote control Switch
Upper System • Temperature Setting • Filter Sign Reset
• Fan Speed Setting

Connecting the JBAA101EWS to an H-LINK • RUN/STOP State Notification • Indoor Suction Temperature Notification
(communication line between machines) Monitoring Item at • Alarm Signal Notification • Alarm Code Notification
Upper System • Operation Mode State Notification • Communication Abnormality Notification
allows control of up to 64 indoor units.
• Fan Speed State Notification • Filter Sign
Up to eight HC-A64BNP can be connected to • Ten parameters setting • Available/Not Available for operation
the same H-LINK. by remote control switch

Connection Method • LonTalk Protocol SNVT(Standard Network Variable Type) FTT-10A


JLAA101EWS (for LONWORKS )
R

To Upper System Free Topology


Coming Soon
JLAA101EWS (Standard)
Number of Connection 64 Remote Controller Group

Control Run/Stop Monitor Run/Stop status & malfunction


Simultaneous Run/Stop Operation Mode setting
Operation Mode setting Temperature setting
Temperature setting Thermo status

JLAA101EWS (Option A)
By using the JLAA101EWS adapter for LONWORKS
R

Number of 64 Remote Controller Group


to connect air conditioners to the total building Connectable RCG
control system, air conditioners can be centrally Control Run/Stop Monitor Run/Stop status & malfunction
Simultaneous Run/Stop Indoor unit Inlet Temperature/
controlled. Operation Mode setting RC Thermo Temperature
Temperature setting
Fan Speed setting
You can select the number of controls, monitor, RC permitted/prohibited (all items)
and what to control in the indoor unit from 4
choices (Standard, Option A and Option B and JLAA101EWS (Option B)
Option C) as needed. Number of 32 Remote Controller Group
Connectable RCG
Control Run/Stop Monitor Run/Stop status & malfunction
Simultaneous Run/Stop Operation Mode setting
Operation Mode setting Temperature setting
Temperature setting Fan Speed setting
Fan Speed setting Louver setting
Louver setting Alarm Code
RC permitted/prohibited (all items) Indoor unit Inlet
Temperature/RC Thermo
Temperature
Temperature Mode Switch Indoor unit Outlet Temperature
Outdoor Temperature

JLAA101EWS (Option C)
Number of 16 Remote Controller Group
Connectable RCG
Control Run/Stop Monitor Run/Stop status
Simultaneous Run/Stop Operation Mode setting
Operation Mode setting Temperature setting
Temperature setting Fan Speed setting
Fan Speed setting Louver setting
Louver setting Thermo status
RC permitted/prohibited (all items) Alarm Code
RC permitted/prohibited Indoor unit Inlet Temperature/
(Run/Stop, Operation Mode setting, RC Thermo Temperature
Temperature setting) Indoor unit Outlet Temperature
Filter Sign Reset Outdoor Temperature
Outdoor unit capacity control RC permitted/prohibited (all items)
Outdoor unit Operating Sound RC permitted/prohibited
Reduction control (Run/Stop, Operation Mode setting,
Temperature Mode Switch Temperature setting)
Outdoor unit control mode Filter Sign

37
Central ...
H-LINK Station H-LINKⅡ
YORK's proprietary high-performance transmis- The H-LINK transmission system for connection between outdoor
sion system for connecting control wiresSpecification
between for Management Computer
and indoor units provides an extended system
Central
indoor andStation mini and between a centralized
outdoorunits, Communication Unit configuration
Units and improved functions without sacrificing
of Adopting for H-LINKⅡ

controlPSC-A32MN
system and indoor/outdoor units, Communication
across twoLine workability
Non-Polar 2-Wire and the flexibility.

or more refrigerant systems. Communication Method Half-Duplex Communication


Synchro System Asynchronous (start-stop synchronous communication)
Example : H-LINKⅡ Control Wiring
Communication Speed 9,600bps
Flexible Wiring Routes Outdoor Unit
Wiring Length 1,000m (Total Length) (Max. 64 Refrigerant System)*
Absolutely no restrictions on the
order of wiring, the
120
Outdoor Unit Indoor Unit Central Controller Total Unit Number
mm
wiring route and the number of branches. Simply
Connecting
64 160 8 200
Unit Number* H-LINKⅡ
connect to the adjacent units or the terminal block of a 16 128 8
Indoor Unit (Max. 160 Units)*
145
H-LINK
centralized control system.
: Connecting unit quantity indicates the maximum unit numbers which is possible to connect in the same H-LINK (Control Wiring).
*
140mm * : The above example shows the case
Regardless of Multi-Split System for Buildings or that central control device, indoor
Functions
units and remote control switch
Packaged System
Most compact for Commercial
in our touch panel Use • Run/Stop/Abnormality are all corresponding
• Accumulated Operating Time • SettingtoLouver
H-LINKⅡ
centralized controller. Its down-to-detail system.
By providing a common control functionMonitor
and wiring
Function • Setting Temperature • Operation Mode • Filter Sign
control functionalities, such as Weekly
method, a multi-split air conditioning system for • RCS Operation
CS-NET Prohibited Setting • Setting Fan Speed
BMS
• Alarm Code
Scheduling, Accumulated Work Hours,
buildings and a packaged air conditioning system • Run/Stop* • Operation Mode • Temperature Setting • Filter Sign Reset
etc., help you save energy. Control Function
for commercial use are simultaneously used in the • Fan Speed • Louver • RCS Operation Prohibited
Up to 32 remote-controlled groups and
same system. Just connect all the systems
*: “All Groupswith
Run/Stop” command signal exception function for selected groups is available by “Exception of Run/Stop Ope.” function.
up to 160 indoor units can be connected
twin core cables by crossover connection. Central Station mini
Centralized ON/OFF
to the single air-conditioning system. Controller
Adapters or other appliances are not required. JCMA101EWS JCOA111EWS JLAA101EWS JBAA101EWS

Specification for Management Computer


H-LINKⅡ
Central System
Station EZ Communication Unit Units of Adopting for H-LINKⅡ

Item PSC-A64GT
Communication Line Non-Polar 2-Wire
H-LINKⅡ
Communication Method Half-Duplex Communication
Max. Number of Refrigerant Group / System 64
Address Setting Range of Indoor Units / Refrigerant Group
Synchro System 0 to 63
Asynchronous (start-stop synchronous communication)
Max. Number of Indoor Unit / System Communication Speed 9,600bps 160
Total Number of Devices in the same H-LINK 200
Wiring Length 1,000m (Total Length)
Max. Wiring Length
170
Total 1,000m
mm Outdoor Unit Indoor Unit Central Controller Total Unit Number
Connecting
Unit Number*
H-LINKⅡ 64 160 8 200
H-LINK 16 128 8 145

System Configuration * : Connecting unit quantity indicates the maximum unit numbers which is possible to connect in the same H-LINK (Control Wiring).

250mm
JUOD Series
Outdoor Unit Functions
H-LINKⅡ
• Run/Stop/Abnormality • Accumulated Operating Time • Setting Louver
Eazy control with 8.5 inch color touch Monitor Function • Setting Temperature • Operation Mode • Filter Sign
Indoor Unit H-LINKⅡ or H-LINK H-LINKⅡ
panel H-LINK
• RCS Operation Prohibited Setting • Setting Fan Speed • Alarm Code
Its down-to-detail control functionalities, • Run/Stop* • Operation Mode • Temperature Setting • Filter Sign Reset
Remote Control Switch Control Function H-LINKⅡ H-LINKⅡ
such as Weekly Scheduling, H-LINK
• Fan Speed • Louver • RCS Operation Prohibited
Accumulated Work
Setting Range of Hours,Group*
Refrigerant etc., 1)help you 0 to 15
Setting Range of Address* 1) *: “All Groups Run/Stop” command signal exception function for selected groups is available by “Exception of Run/Stop Ope.” function.
save energy. Up to 64 remote-controlled 0 to 15 0 to 15 0 to 63
Automatic Reset of Setting Temperature* 2)
groups and up to 160 indoor units can
Operation Lock*2) *1): The range of ref. group setting and address
be connected to the single setting is 0 to 15 when H-LINK corresponding
Limitation of Setting Temperature Range*3)
air-conditioning system. 2) central controller is used.
ON / OFF Timer Setting (72Hr.)*
*2): These functions can be set by wired remote
Different Operation Mode Indication*3) control switch only.
Indoor Unit Hot-Start Indication*3) *3): These functions can be set by wired remote
control switch.
Change of Indoor Unit Ref. Group No. and Address*2)
Outdoor Unit Comp. Pre-heating Indication / Cancel*2)
Emergency Operation from Remote Control Switch

37 38
Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other
trademarks used herein may be trademarks or registered trademarks of other companies.
FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM
© 2016 Johnson Controls, Inc, P.O. Box 423, Milwarkee, WI 53201, All rights reserved worldwide. JUOD-VPEM0AS-170329