Vous êtes sur la page 1sur 4

DOCUMENTO:

HOJA DE DATOS COA-1807-MEC-DC-HD-001


DOCUMENTO eB:
LÍNEA DE INYECCIÓN DE AGUA DE
PLANTA PCH REVISION ACTUAL:
B
FECHA DE EMISION:
HOJA DE DATOS DE VALVULA
12/29/2018
PSV - 8040
HOJA 1 DE 6

LISTA DE MODIFICACIONES

Elaborado por: Revisado por: Aprobado por:


D.R.G.

Ingeniero de Procesos
DOCUMENTO:
HOJA DE DATOS
DOCUMENTO eB:
LÍNEA DE INYECCIÓN DE AGUA DE
PLANTA PCH REVISION ACTUAL:
B
FECHA DE EMISION:
HOJA DE DATOS DE VALVULA 12/29/2018
PSV - 8040 HOJA 1 DE 2
GENERAL BASIS OF SELECTION
1. 5. Code: ASME
Item Number: 1 Stamp Required: Yes ✘ No
VIII
2. Tag Number: PSV-8040 Other Specify:
3. Service, Line, or Equipment Number: 1"-0.179-B(V-1)-9500 6. Comply with API 526: ✘ Yes No
4. Number Required: 1 7. Fire ✘ Othe Specify: Outlet Blocked
8. Rupture Disk:r Yes ✘ No
VALVE DESIGN MATERIALS
9. Design Type: 17. Body: SA 216 WCB
Convention Balanced
✘ Bellows 18. Bonnet: Capuchon H2
al Piston
10. Nozzle Type: Full Semi 19. Seat (Nozzle): Disc: Hardened Stainless steel
Other Specify: 20. Resilient Seat:
11. Bonnet Type: Open ✘ Closed 21. Guide: Carbon steel/chrome st Tenifer
12. Seat Type: Metal-to- 22. Adjusting Ring (s): Crhome steel
✘ Resilient
13. Seat Tightness: Metal
API 23. Spring: Alloy Steel Washer: Hardened stainless steel
Other Specify:527 24. Bellows:
25. Balanced Piston: N/A
CONNECTIONS N
26. Comply with NACE: Yes
o
14. Inlet Size: 1" Rating #600 Facing RF 27. Internal Gasket Materials:
15. Outlet Size: 2" Rating #150 Facing RF 28. Othe Specify:
16. ✘ Othe Specify: ASME B16.5 r
r

SERVICE CONDITIONS ACCESSORIES


34. Fluid and State: Salmuera/liquido 29. Cap: Screwe Bolte
35. Required Capacity per Valve and Units: 9,3 gpm 30. Lifting Lever:d d Packe Non
Plain
d e
36. Mass Flux and Basis: -- 31. Test Gag: Yes No
37. Molecular Weight or Specific Gravity: -- 32. Bug Screen: Yes No
38. Viscosity at Flowing Temperature and Units: 0,87 cP 33. Othe Specify:
r
39. Operating Pressure and Units: 1360 psig
40. Set Pressure and Units: 720 - 1400 psig (Nota 1)
41. Blowdown: Standar Othe
d r
42. Latent Heat of Vaporization and Units:
SIZING AND SELECTION
43. Operating Temperature and Units: 80°F
44. Relieving Temperature and Units: 80°F 51. Calculated Orifice Area (in square inches): 0.018 in2
45. Built-up Back Pressure and Units: 5 PSI 52. Selected Effective Orifice Area (in square inches): 0.110 in2
46. Superimposed Back Pressure and Units: 53. Orifice Designation (letter): D
47. Cold Differential Test Pressure and Units: 54. Manufacturer: LESER
48. Allowable Overpressure in Percent or Units: 10.00% 55. Model Number:
49. Compressibility Factor, Z: N/A 56. Vendor Calculations Requerid: Yes ✘ No
50. Ratio of Specific Heats:
VALVE - DIMENSIONS
51 Discharge area Ao 0.239 in²
52 Diameter of discharge do 0.551 inch
53 Distances center-face flange a 105 mm
54 Distances center-face flanges b 114 mm
55 Height H 440 mm
56 Weight M 17.3 kg
57 Center to face dimensions S1 30 mm
NOTAS
La PSV debe ser capaz de poder ser seteada entre 720 y 1400 psig
1 para diferentes condiciones de operación durante la vida del
proyecto.