Tape for Masterflex Sealing System for irregular and unconventional joints
DESCRIPTION elongation of 2-
5%) DIN 53457 S2
Masterflex joint sealing system consists of two products;
the Masterflex Tape and Concresive 1438 epoxy. Approx. 900
Weight per unit
The Masterflex Tape is a highly elastic, rot-proof and (1mm)
Area g/m2 DIN -
chemically resistant sealing membrane. Approx. 1800
53352 5.4,
Concresive 1438 is a two part epoxy compounds which (2mm)
establishes a strong bond to various types of substrate. Colour (RAL) Approx. 7045 Approx. 7045
Tensile Strength
RECOMMENDED FOR Mpa DIN 53504 >6 9.3 / 7.8
S2
Sealing construction joints, expansion joints, connecting
Elongation at
joints, cracks and crevices, etc. Adheres to many types
Break, % DIN > 400 740 / 713
of substrate such as concrete, mortar, plaster work, steel
53504 S2
iron, aluminium, stoneware, glass and epoxy.
Tear propagation
Typical use is for concrete tanks, cast, cement pipe
Resistance, N/cm - 641 / 695
connections, bridge decks, tunnels, water towers and
DIN 53363
reservoirs, ponds, silos, containers, secondary tanks.
Masterflex can be applied on dry or slightly humid Cold Flexibility SIA o o
-20 C -35 C
substrates. It is ideal for joints with very large expansion 280/3
or irregular, broken joint flanks. Loss in
Resistance to
Masterflex tape, of grey colour, is weather and o weight < 3% Passed
Aging (70d/70 C)
waterproof. Reduction in
SIA 280/8
Elongation < Passed
DIN 53504 S2
FEATURE & BENEFITS 30%
Shore A Hardness
75 ± 10 80
ISO 868
• Durable
Potable Water test
• Long lasting elasticity, even at low temperatures Suitable Passed
Swiss Food Act
• Root resistant Bitumen
• Resistant to a wide range of chemicals Compatibility Compatible Passed
• Cost effective DIN 16726/5.19
Water Pressure
• Easy to apply
Test MBT method 24 h 1 bar Passed
• No extra cleaning or activating of the tape φ30mm
• User friendly welding of TAPE overlaps
• Can be applied horizontally, vertically and even PROPERTIES
overhead.
Shore-Hardness A (ISO 868) : approx. 80
TYPICAL PERFORMANCE DATA
Specification Tensile strength (DIN 53504 S2) : > 6 N/mm2
Description Results
s
Elongation at break : approx. 600%
Surface (DIN 53504 S2)
Flat/Smooth Flat
appearance
Resistance to further cracking : approx. 600N/cm
Specification
Description Results (DIN 53363)
s
o
Thickness, mm Approx. 1 / Accelerated weathering (SIA 280/3): No cracks –50 C
1 or 2
DIN 533537 5.3 Approx. 2
Tensile strength, Waterproofing : passes the joint
Mpa (modulus < 30 20.7 pressure test
between
PACKAGING
Masterflex Tape dimensions:
Thickness: 1 mm
Width 100 mm 250 mm
150 mm 300 mm
200 mm 500 mm
Thickness: 2 mm
Width 150 mm 300 mm Fig 4. Hidden expansion joint e.g. car parks
200 mm 500 mm 1 Masterflex 3000
In rolls of 20 m length (all sizes) 2 Concresive 1438
3 nosing mortar
SHELF LIFE
Masterflex 3000 can be kept for 12 months from date of
manufacture if stored in well protected area away from
sunlight, at ambient temperature in dry conditions.
MASTERFLEX® 3000
o
Fig 5. Sealing of a 90 construction joint Fig 6. Waterproofing of specific joints
1 Masterflex 3000 1 Masterflex 3000
2 Concresive 1438 2 Concresive 1438
3 Bedding Mortar, for ex. EMACO 3 nosing mortar
4 bearing
PRECAUTIONS
For Health, Safety and Environmental
Recommendations, please consult and follow all
instructions in the product Material Safety Data Sheet.
M3000/02/0201
The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.