General Data PK3L P34 PK4L P35 PK5L

Area Tumpuan Lapangan Tumpuan Lapangan Tumpuan


Mult 7013.98 12244.5641 11696.70 13428.62 14285.71
Vult 2670.91 3577.49 3577.49 4094.00 4094.00

Reinforcement
Original Design
f'c 40.00 40.00 40.00 40.00 40.00
b 700.00 700.00 700.00 700.00 700.00
h 2000.00 2000.00 2000.00 2000.00 2000.00
D rebar 32.00 32.00 32.00 32.00 32.00
fy 400.00 400.00 400.00 400.00 400.00
n lapis 1 13.00 12.00 22.00 25.00 21.00
a 202.65 162.12 297.22 337.75 283.71
d 1960.00 1460.00 1960.00 1460.00 1960.00
Mn 8964.47 5320.55 12813.40 10378.59 12276.59
фMn 7619.80 4522.47 10891.39 8821.80 10435.10
Control Oke Koreksi Koreksi Koreksi Koreksi

Rectification
f'c - 40.00 - 40.00 -
b - 700.00 - 700.00 -
h - 2000.00 - 2000.00 -
D rebar - 32.00 - 32.00 -
fy - 400.00 - 400.00 -
n lapis 2 - 3.00 - 3.00 -
a - 40.53 - 40.53 -
d - 1960.00 - 1960.00 -
Mn - 1871.08 - 1871.08 -
фMn - 1590.42 - 1590.42 -
ΣфMn - 6112.89 - 10412.22 -
Control - Koreksi - Koreksi -

Wrapping
Momen Sisa - 6131.68 805.31 3016.40 3850.61
w strip - 75.00 75.00 75.00 75.00
h strip - 1.20 1.20 1.20 1.20
fy - 3000.00 3000.00 3000.00 3000.00
n - 15.00 2.00 4.00 15.00
z - 2000.00 2000.00 2000.00 2000.00
Aw - 1350.00 180.00 360.00 1350.00
a - 170.17 22.69 45.38 170.17
Mn - 7755.40966 1073.874 2135.496 7755.41
фMn - 6592.09821 912.7929 1815.171 6592.098
Control Oke Oke Oke Koreksi Oke
1 FLEXURAL REINFORCEMENT BEAM IN PLASTIC ZONE OF ECS PIT

DESIGN DATA
Mu = 7013.98 kN m fc' = 40 MPa
b = 700 mm fy = 400 MPa
h = 2000 mm ∂ = 0.5
d' = 40 mm D = 32 mm
d = 1960 mm As1 = 804.248 mm2
β = 0.85
L = 16500 mm

Check dimention
SNI (2847 : 2013)
h ≥ L / 14 = 1179 = 1500

Reinforcement ratio ;
Aρ2 + Bρ + C = 0
by formula ;
0.59 x ( 1 - ∂ )2 x fy2
A =
fc'
= 590

B = - [ { (1-∂) x fy } + {∂ x fy x (1-d'/d) } ]
= -395.9184

C = Mu
Ø x b x d2
= 3.2603532
by using ABC formula, we can get reinforcement ratio ;
ρ1 = 0.662709552
ρ2 = 0.0083385282

Take the minimum one ;


ρ = 0.0083385

fs' = 600 x {1 - d'/d x (600 + fy/600)}


= 579.59

ρb = 0.85 x β x (fc' / fy ) x ( 600 / 600 + fy ) + ρ' x ( fs' x fy )


= 0.04335

ρmax = 0,75 x ρb
= 0.0325125

ρmin = √ fc' ρmin = 1.4


4 x fy fy
= 0.0039528471 = 0.0035

ρmin ≤ ρ ≤ ρmax
0.0039528471 0.008339 0.0325125

So, we can use ;


ρ = 0.0083

Total area as required ;


Tensile
As = ρ x b x d
= 11440.461 mm 2

Compression
As = ∂ x ρ x b x d
= 5720.2304 mm 2

Number of rebar ;
n = As
As1
= 14.225046 ≈ 15 pcs

15 - D 32 Top

Check momen capacity ;

a = As x fy
0.85 x fc' x be
= 203 mm

Mn = As x fy x (d - 0.5a)
= 8964.4669 kNm

фMn = 7619.7969 > Mu = 7013.985 ...OK


1 FLEXURAL REINFORCEMENT BEAM IN PLASTIC ZONE OF ECS PIT

DESIGN DATA
Mu = 12244.56 kN m fc' = 40
b = 700 mm fy = 400
h = 2000 mm ∂ = 0.5
d' = 40 mm D = 32
d = 1460 mm As1 = 804.248
β = 0.85
L = 16500 mm

Check dimention
SNI (2847 : 2013)
h ≥ L / 14 = 1179 = 1500

Reinforcement ratio ;
Aρ2 + Bρ + C = 0
by formula ;
0.59 x ( 1 - ∂ )2 x fy2
A =
fc'
= 590

B = - [ { (1-∂) x fy } + {∂ x fy
= -394.5205479

C = Mu
Ø x b x d2
= 10.257690484
by using ABC formula, we can get reinforcement ratio ;
ρ1 = 0.6415803139
ρ2 = 0.027098581

Take the minimum one ;


ρ = 0.02709858

fs' = 600 x {1 - d'/d x (600 + fy/600)}


= 572.60

ρb = 0.85 x β x (fc' / fy ) x ( 600 / 600 + fy ) + ρ' x ( fs' x fy )


= 0.04335

ρmax = 0,75 x ρb
= 0.0325125

ρmin = √ fc' ρmin = 1.4


4 x fy fy
= 0.0039528471 = 0.0035

ρmin ≤ ρ ≤ ρmax
0.0039528471 0.027099 0.0325125

So, we can use ;


ρ = 0.0271

Total area as required ;


Tensile
As = ρ x b x d
= 27694.7497 mm 2

Compression
As = ∂ x ρ x b x d
= 13847.3749 mm 2

Number of rebar ;
n = As
As1
= 34.4355962 ≈ 12 pcs

12 - D 32 Bottom

Check momen capacity ;

a = As x fy
0.85 x fc' x be
= 162.12 mm

Mn = As x fy x (d - 0.5a)
= 5320.5 kNm

фMn = 4522.5 > Mu = 12244.564


MPa
MPa

mm
mm2

x (1-d'/d) } ]
1 FLEXURAL REINFORCEMENT BEAM IN PLASTIC ZONE OF ECS PIT

DESIGN DATA
Mu = 12244.56 kN m fc' = 40
b = 700 mm fy = 400
h = 2000 mm ∂ = 0.5
d' = 40 mm D = 32
d = 1960 mm As1 = 804.248
β = 0.85
L = 16500 mm

Check dimention
SNI (2847 : 2013)
h ≥ L / 14 = 1179 = 1500

Reinforcement ratio ;
Aρ2 + Bρ + C = 0
by formula ;
0.59 x ( 1 - ∂ )2 x fy2
A =
fc'
= 590

B = - [ { (1-∂) x fy } + {∂ x
= -395.918367

C = Mu
Ø x b x d2
= 5.69171518
by using ABC formula, we can get reinforcement ratio ;
ρ1 = 0.6563501716
ρ2 = 0.0146979087

Take the minimum one ;


ρ = 0.0146979

fs' = 600 x {1 - d'/d x (600 + fy/600)}


= 579.59

ρb = 0.85 x β x (fc' / fy ) x ( 600 / 600 + fy ) + ρ' x ( fs' x fy )


= 0.04335

ρmax = 0,75 x ρb
= 0.0325125

ρmin = √ fc' ρmin = 1.4


4 x fy fy
= 0.0039528471 = 0.0035

ρmin ≤ ρ ≤ ρmax
0.0039528471 0.014698 0.0325125

So, we can use ;


ρ = 0.0147

Total area as required ;


Tensile
As = ρ x b x d
= 20165.531 mm 2

Compression
As = ∂ x ρ x b x d
= 10082.765 mm 2

Number of rebar ;
n = As
As1
= 25.07378 ≈ 3

3 - D 32 Bottom

Check momen capacity ;

a = As x fy
0.85 x fc' x be
= 40.53 mm

Mn = As x fy x (d - 0.5a)
= 1871.1 kNm

фMn = 1590.4 > Mu = 12244.564


40 MPa
400 MPa
0.5
32 mm
804.248 mm2

fy x (1-d'/d) } ]
0.0035

pcs
1 FLEXURAL REINFORCEMENT BEAM IN PLASTIC ZONE OF ECS PIT

DESIGN DATA
Mu = 11696.70 kN m fc' = 40 MPa
b = 700 mm fy = 400 MPa
h = 2000 mm ∂ = 0.5
d' = 40 mm D = 32 mm
d = 1960 mm As1 = 804.248 mm2
β = 0.85
L = 15000 mm

Check dimention
SNI (2847 : 2013)
h ≥ L / 14 = 1071 = 1500

Reinforcement ratio ;
Aρ2 + Bρ + C = 0
by formula ;
0.59 x ( 1 - ∂ )2 x fy2
A =
fc'
= 590

B = - [ { (1-∂) x fy } + {∂ x fy x
= -395.9184

C = Mu
Ø x b x d2
= 5.4370482
by using ABC formula, we can get reinforcement ratio ;
ρ1 = 0.657022167
ρ2 = 0.0140259132

Take the minimum one ;


ρ = 0.0140259

fs' = 600 x {1 - d'/d x (600 + fy/600)}


= 579.59

ρb = 0.85 x β x (fc' / fy ) x ( 600 / 600 + fy ) + ρ' x ( fs' x fy )


= 0.04335

ρmax = 0,75 x ρb
= 0.0325125

ρmin = √ fc' ρmin = 1.4


4 x fy fy
= 0.0039528471 = 0.0035

ρmin ≤ ρ ≤ ρmax
0.0039528471 0.014026 0.0325125

So, we can use ;


ρ = 0.0140

Total area as required ;


Tensile
As = ρ x b x d
= 19243.553 mm 2

Compression
As = ∂ x ρ x b x d
= 9621.7765 mm 2

Number of rebar ;
n = As
As1
= 23.927395 ≈ 22 pcs

22 - D 32 Top

Check momen capacity ;

a = As x fy
0.85 x fc' x be
= 297 mm

Mn = As x fy x (d - 0.5a)
= 12813.403 kNm

фMn = 10891.392 > Mu = 11696.700


(1-d'/d) } ]
1 FLEXURAL REINFORCEMENT BEAM IN PLASTIC ZONE OF ECS PIT

DESIGN DATA
Mu = 13428.62 kN m fc' = 40
b = 700 mm fy = 400
h = 2000 mm ∂ = 0.5
d' = 40 mm D = 32
d = 1460 mm As1 = 804.248
β = 0.85
L = 15000 mm

Check dimention
SNI (2847 : 2013)
h ≥ L / 14 = 1071 = 1500

Reinforcement ratio ;
Aρ2 + Bρ + C = 0
by formula ;
0.59 x ( 1 - ∂ )2 x fy2
A =
fc'
= 590

B = - [ { (1-∂) x fy } + {∂ x fy
= -394.5205479

C = Mu
Ø x b x d2
= 11.249612967
by using ABC formula, we can get reinforcement ratio ;
ρ1 = 0.6388320179
ρ2 = 0.0298468769

Take the minimum one ;


ρ = 0.02984688

fs' = 600 x {1 - d'/d x (600 + fy/600)}


= 572.60

ρb = 0.85 x β x (fc' / fy ) x ( 600 / 600 + fy ) + ρ' x ( fs' x fy )


= 0.04335

ρmax = 0,75 x ρb
= 0.0325125

ρmin = √ fc' ρmin = 1.4


4 x fy fy
= 0.0039528471 = 0.0035

ρmin ≤ ρ ≤ ρmax
0.0039528471 0.029847 0.0325125

So, we can use ;


ρ = 0.0298

Total area as required ;


Tensile
As = ρ x b x d
= 30503.5082 mm 2

Compression
As = ∂ x ρ x b x d
= 15251.7541 mm 2

Number of rebar ;
n = As
As1
= 37.9280009 ≈ 25 pcs

25 - D 32 Bottom

Check momen capacity ;

a = As x fy
0.85 x fc' x be
= 337.75 mm

Mn1 = As x fy x (d - 0.5a)
= 10379 kNm

Mn2

фMn = 8821.8 > Mu = 13428.618


MPa
MPa

mm
mm2

x (1-d'/d) } ]
1 FLEXURAL REINFORCEMENT BEAM IN PLASTIC ZONE OF ECS PIT

DESIGN DATA
Mu = 13428.62 kN m fc' = 40
b = 700 mm fy = 400
h = 2000 mm ∂ = 0.5
d' = 40 mm D = 32
d = 1960 mm As1 = 804.248
β = 0.85
L = 15000 mm

Check dimention
SNI (2847 : 2013)
h ≥ L / 14 = 1071 = 1500

Reinforcement ratio ;
Aρ2 + Bρ + C = 0
by formula ;
0.59 x ( 1 - ∂ )2 x fy2
A =
fc'
= 590

B = - [ { (1-∂) x fy } + {∂ x fy
= -395.918367

C = Mu
Ø x b x d2
= 6.242106154
by using ABC formula, we can get reinforcement ratio ;
ρ1 = 0.6548930126
ρ2 = 0.0161550677

Take the minimum one ;


ρ = 0.0161551

fs' = 600 x {1 - d'/d x (600 + fy/600)}


= 579.59

ρb = 0.85 x β x (fc' / fy ) x ( 600 / 600 + fy ) + ρ' x ( fs' x fy )


= 0.04335

ρmax = 0,75 x ρb
= 0.0325125

ρmin = √ fc' ρmin = 1.4


4 x fy fy
= 0.0039528471 = 0.0035

ρmin ≤ ρ ≤ ρmax
0.0039528471 0.016155 0.0325125

So, we can use ;


ρ = 0.0162

Total area as required ;


Tensile
As = ρ x b x d
= 22164.753 mm 2

Compression
As = ∂ x ρ x b x d
= 11082.376 mm 2

Number of rebar ;
n = As
As1
= 27.559609 ≈ 3 pcs

3 - D 32 Bottom

Check momen capacity ;

a = As x fy
0.85 x fc' x be
= 40.53 mm

Mn = As x fy x (d - 0.5a)
= 1871.1 kNm

фMn = 1590.4 > Mu = 13428.618


MPa
MPa

mm
mm2

x (1-d'/d) } ]
1 FLEXURAL REINFORCEMENT BEAM IN PLASTIC ZONE OF ECS PIT

DESIGN DATA
Mu = 14285.71 kN m fc' = 40 MPa
b = 700 mm fy = 400 MPa
h = 2000 mm ∂ = 0.5
d' = 40 mm D = 32 mm
d = 1960 mm As1 = 804.248 mm2
β = 0.85
L = 15000 mm

Check dimention
SNI (2847 : 2013)
h ≥ L / 14 = 1071 = 1500

Reinforcement ratio ;
Aρ2 + Bρ + C = 0
by formula ;
0.59 x ( 1 - ∂ )2 x fy2
A =
fc'
= 590

B = - [ { (1-∂) x fy } + {∂ x fy x
= -395.9184

C = Mu
Ø x b x d2
= 6.6405134
by using ABC formula, we can get reinforcement ratio ;
ρ1 = 0.6538340682
ρ2 = 0.017214012

Take the minimum one ;


ρ = 0.017214

fs' = 600 x {1 - d'/d x (600 + fy/600)}


= 579.59

ρb = 0.85 x β x (fc' / fy ) x ( 600 / 600 + fy ) + ρ' x ( fs' x fy )


= 0.04335

ρmax = 0,75 x ρb
= 0.0325125

ρmin = √ fc' ρmin = 1.4


4 x fy fy
= 0.0039528471 = 0.0035

ρmin ≤ ρ ≤ ρmax
0.0039528471 0.017214 0.0325125

So, we can use ;


ρ = 0.0172

Total area as required ;


Tensile
As = ρ x b x d
= 23617.625 mm 2

Compression
As = ∂ x ρ x b x d
= 11808.812 mm 2

Number of rebar ;
n = As
As1
= 29.366107 ≈ 21 pcs

21 - D 32 Top

Check momen capacity ;

a = As x fy
0.85 x fc' x be
= 284 mm

Mn = As x fy x (d - 0.5a)
= 12276.586 kNm

фMn = 10435.098 > Mu = 14285.710


(1-d'/d) } ]