Vous êtes sur la page 1sur 11

SEWO high speed flap gate series

Install manual

Content

1.equipment introduction 1
1.1 introduction 1
1.2 features 1
1.3 specification 1
2.housing dimension 2
2.1housing dimension 2
3.equipment structure & working principle 3
3.1 flap gate mechanical system 3
3.2 flap gate electronic control system 3
3.3 system working principle 3
4.equipment installation & testing 4
4.1 equipment installation 4
4.2 equipment testing 4
4.3 flap gate fixing 4
4.4 install dimension 5
5.specification setting & operating manual 7
6.FAQ & maintenance 9
7.equipment operating manual 9
1.equipment introduction
1.1 introduction
Intelligent channel gate is an intelligent channel management equipment developed
and produced by our company after many years of development. The device integrates
mechanical, electronic, microprocessor control and various reading and writing
technologies. Through the configuration of various reading and writing devices, the use
of reliable security protection devices and real-time alarm system and direction
indication interface, coordinate the intelligent control and management of the channel.
The shape is stamped and formed by stainless steel plate. It is beautiful in appearance,
rust-proof and durable. It adopts standard electrical interface and can easily integrate bar-
code reader, ID card, IC card and other card readers on the device to provide civilization
for the inbound and outbound personnel. The orderly way of passing, at the same time can
prevent illegal personnel from entering and exiting; in addition, the system also specially
designed to meet the requirements of fire protection requirements, in the event of an
emergency, to ensure that the passage is unimpeded and convenient for personnel to
evacuate in time.

1.2. Features
1) The main device of the device adopts automotive grade chip, and the rest of the
devices adopt industrial grade device to ensure stable operation of the system;
2) The whole process of detecting the operation status of the gate to ensure the
safety of pedestrians;
3) The movement structure adopts 24V DC brushless motor + encoder technology;
4) Anti-collision and anti-pinch function;
5) With zero self-test function, it is convenient for users to maintain and use;
6) Illegal intrusion, reverse traffic, trailing alarm function;
7) With automatic reset function, if the pedestrian reads the valid card, if the system
does not pass within the specified time, the system will automatically cancel the
pedestrian access right;
8) Unified standard external electrical interface, which can be connected with a
variety of card readers, and can be remotely controlled and managed through a
management computer;
9 ) The whole system runs smoothly, with low noise, and the noise index is less than
55 decibels;
10 ) The service life is more than 5 million times.

1.3 specification
1) Product size: 1500*300*1000mm
2) Box material: SUS304/1.5mm
3) Power supply voltage: AC220±10% V, 50HZ

1
4) Drive motor: DC motor 24 V/70W
5) Working environment temperature: -15 O C - 70 O C
6) Relative humidity: relative humidity ≤ 90% , no condensation
7) Input interface: 12V level signal or pulse width> 12V drive current
pulse of 100 ms> 10 mA
8) Communication interface: TCP/IP network interface
9) Channel width: 550MM
10) Passing speed: 35 people / minute
11) One-way switching time: 0.5 seconds

2.housing dimension
2.1 housing dimension

Equipment dimensions refer to the figure.

3. equipment structure & working principle


3.1 speed gate mechanical system
The speed gate mechanical system is divided into two parts: the chassis and the
movement. The chassis serves as a carrier, and is equipped with a direction indicator, a

2
reading and writing device, an infrared sensor, etc.; the movement consists mainly of a
motor, a frame, a drive shaft, a gate.

3.2 speed gate electronic control system

The electronic control system consists of a card reader, a main control board, an
infrared sensor, a direction indicator, an alarm, a limit switch, and a transformer.

Card reader (self-prepared): After reading the information on the card and after judging the
processing, it sends an application pass signal (switch signal) to the main control board.

Main control board: The control center of the system, which receives the signals of the card
reader and the infrared sensor, and performs logical judgment and processing on these
signals, and then issues an execution command to the direction indicator, the motor, the
counter, and the alarm. Infrared sensor: detects pedestrian position and plays a safety
role;Direction indicator: displays the current status of the channel and guides pedestrians
through the channel in a safe and orderly manner.

Alarm: When the system detects a pedestrian who has illegally entered the channel, it will
give an alarm prompt.

Limit switch: the position at which the gate is controlled to rotate.

3. 3 system working principle


1) Turn on the power, and the system will enter the working state after 3 seconds.
2) When the card reader reads the valid card, the buzzer will make a pleasant
sound, prompting the pedestrian to read the card successfully; at the same
time, it also judges and processes the information read from the card, and
sends an application signal to the main control board;
3) The main control board receives the signals of the card reader and the infrared
sensor, and after comprehensive processing, sends an effective control signal
to the direction indicator and the motor, so that the direction indicator turns
into a green arrow pass sign, and if the system is in the normally closed mode.
When the motor is running, the limit switch controls the electricity.
The angle of the motor is turned, the gate is opened (the motor does not move
when the mode is normally open), and pedestrians are allowed to pass;
4) After the pedestrian indicates the passage through the passage according to the
direction indicator mark, the infrared sensor senses the pedestrian pass
Pass the entire process of the channel and continuously send a signal to the main
control board until the pedestrian has completely passed through the channel;
5 ) If the pedestrian forgets to read the card or reads the invalid card into the
channel, the system will prohibit pedestrians (for the normally open mode, the
gate will be closed; the normally closed mode, the gate will not operate;), and

3
an alarm will be issued until the pedestrian exits the channel. Release the
alarm; re-read the valid card to allow access ;

4.Equipment installation & testing


4.1. Equipment installation:
1.4+4+2 core wire 5 meters. (4 core man-machine terminal (host) and movement
controller (auxiliary machine) cable +4 core reader cable + 2 core power cable, access
control board needs to be more than one network cable.)
2. Tools: impact drill, M 10× 100 expansion screws, hex wrench M5 , M6 , M10
wrench, slot cutter, cross knife, wire stripper, multimeter, tape measure, hand hammer,
adjustable wrench.

4.2. equipment testing

Remarks:
1. The two gates form a channel, the control board, the movement controller, and
the three-core infrared (receiving end) are the main unit. Only the movement controller and
the two-core infrared (transmitting end) are auxiliary machines.

4.3. flap gate fixing


1. Determine the installation location of each gate according to the specific system
composition, the site of use, and the model selected.
2. According to the requirements of the installation diagram, determine the installation
hole position, and pre-bury 4 M10 anchor screws or 4 M10 expansion screws at the
installation position.
3. When fixing the gate, please arrange the gates neatly (three-core infrared (receiving
end) and two-core infrared (transmitting end) form a channel) to detect whether the electric
eye is aligned (the electric eye is not blocked after power-on) Next, the control board
buzzer on the main unit is not called, the three-core infrared display light is not red, the
upper traffic indicator on the control board is not lit, and the side indications are green,
indicating normal, before the card can be swiped in and out). If the swinging door is
aligned, it can be fixed only after it is confirmed.

4.4.install dimension(mm ):
4.4. Installation dimensions (unit: mm):

4
Please connect the cable correctly. If there is a door panel, you need to connect the
head cable on the slave to the access panel through the cable. Then connect the power cable
to the air switch and turnon the power switch. Run to the off state, please do not stand
within the range of gate operation at this time).

4.5. Description of the connection between the control board (host) and
the movement controller (slave)
4.5.1, the host side, there is a marked positive (FIG. A) on a drive plate connected to a
power supply 1, labeled 2 is then negative, then CANL 3 is marked, the marked contact
CANL 4.
4 .5.2, slave side, is marked with a positive (FIG. B) on the drive plate connected to the
power supply 1 is marked with the negative electrode 2 is connected, then CANL 3 is
marked, the marked contact CANL 4.

5
Warning :
1. The depth of the buried PVC pipe should be greater than 60 mm , the exposed ground
height should be greater than 50 mm , and the exit bends back to prevent the pipe from
entering the water.
2. When installing the channel gate, the left and right gates of each channel should be
aligned;
3. Connect the system protection ground wire;
4. If the equipment is used outdoors, a cement platform with a height
of 100 ~ 200mm should be built at the installation site to protect the tide, and a sunscreen
and rainproof facilities such as a ceiling should be added;
5. After the equipment is installed, the status check and function debugging are
qualified before it can be put into normal use.

After the device status check is normal, the following functions can be debugged!

Channel wing gate debugging instructions

First, preparation before commissioning


Check the mains wiring according to the wiring diagram. Check that the power wiring
and other wiring of the entire equipment are correct. After confirmation, you can power on
and debug!
The protection ground of the equipment must be grounded reliably, otherwise it is not
allowed to use.

Second, the hardware configuration


The two-way speed-passing door is a double electric eye, and the one-way speed-
passing door is a single electric eye.

5.specification setting & operating manual


5.1 Universal Description
1. The display refers to the 3 -digit LED displayed from left to right on the main control
board ;
2. The three buttons from the left to the right are the INC button, the SET button,
the DEC button, and the SET button for entering and exiting.
Menu or enter and exit function settings; INC key is used to add 1 to the

5.2 to enter and exit the menu settings


1. Enter the menu: press the SET button, after hearing the “beep”, release
the SET button. At this time, the display shows “ P00 ”, indicating that you have entered
the menu setting state. At this time, the INC button and the DECbutton can be used. To
select the function number of the setting function; press the INC key, the function

6
number is increased by 1 , and the DEC key is reduced by 1 ; there are 15 function
settings, respectively:
P00 : Exit the menu setting function. When P00 appears , press the SET button to exit the
menu setting;
P01 : Running direction when the motor is powered on, =000 : forward rotation when
power is on, =001 reverse when powering up. (factory is 001 )
P02 : The maximum running time of the gate, the unit is 0.1 second. If the time is set
to 60, that is, 6 seconds, the gate will stop closing when the gate is not closed for 6 seconds
(the system default is 60 )
P03: pedestrians time, in seconds, so 10 is the time to 10 seconds after passing pedestrians
credit card is not canceled within a set time the card. (The system default is 10 )
P04 : Working mode (system default is 000 )
=000 : two-way swipe
=001 : Inward swipe, free to go
=002 : Freedom of movement, outgoing card
=003 : Freedom of movement, freedom of movement
=004 : Opening the gate (one way)
=005 : Outbound opening (one way)

P05 : Speed of opening the door: the speed at which the gate is closed from the position to
the position in the forward direction. (The system default is 10 )
P06 : Forward closing speed: the speed at which the gate moves from the forward to the
closed position. (The system default is 10 )
P07 : Outward opening speed: the speed at which the gate is closed from the position to the
out position. (The system default is 10 )
P08 : Outbound closing speed: the speed at which the gate moves from the out to the
position to the off position. (The system default is 10 )
P09 : The pedestrian transit interval is considered to be one person within the set time (the
system default is 10 )
P10 : The forward counter is cleared. When the P10 is displayed , press the SET button to
display C — L . After pressing the INC button, the system sends a forward count clear
signal and the feed counter is cleared.
P11 : The outbound counter is cleared. When the P11 is displayed , press the SET button to
display C — L . After pressing the INC button, the system will send a count clear signal
and the outbound counter will be cleared.
P12 : With memory / without memory setting (system default is 000 )
=000 : two-way with memory,
=001 : There is no memory in the heading and memory in the out direction.
=002 : The memory is in the forward direction, and the memory is in the outgoing
direction.
=003 : Two-way without memory.
P13 : The device communication address, that is, the number of
machines. Range 1 — 255 . (The system default is 001 )
7
P14 : device type
P15 : The system restores the default value. When P is displayed , press SET to
display P — 2 Press INC now.
The key system restores the default value.
P16: The door opening direction is adjusted when the communication is opened. When =0,
it is in one direction, and when it is 1, it is in the opposite direction. In order to ensure that
the two gates of the same channel are in the same direction, the side is set to 0 and the side
is set to 1.
P17: How long does it take for the pedestrian to turn off after passing the system? There is
no delay when the gate is normal. If the gate
When it is long, the pedestrian will immediately close the door and then hit the pedestrian
to adjust the delay to avoid it.

2. Exit the menu setting: Press the INC key or the DEC key. When
the P00 character appears , press the SET key to exit the menu setting. (A smaller
value than the speed of the faster speed.)

Note: 1. Peripheral equipment must not be added to the system without permission;
2. If the debugging result is inconsistent with the function during debugging, please
refer to the section Common Faults and Troubleshooting.

6.FAQ & maintenance


6.1 After brushing card, the door does not swing open the door, nothing happens, or power
failure does not automatically open, re-check whether the signal lines have dropped open,
above board to see if there is open signal indicator received open signal.
6.2 The working states indicated by the direction are,respectively,the green arrow points to
the left, points to the right, or the red cross. If the direction indication does not respond, or
the direction indicated is incorrect.You can switch to another test and try it with a good
one. Recheck the wiring.
6.3 flap gate has an automatic opening function after the power is turned off. If it does not
turn on after the power is turned off, the reason is that the backup battery (battery) voltage
inside is not enough, and the voltage of the multimeter can be used more than 10V.

8
6.4 flap gate is swiped, one is open and one is not open. Recheck that the sync cable is
connected. After ensuring the connection, the motherboard that cannot be opened has
received the signal of the opening. If not, recheck whether the wiring is dropped or not, and
whether the plug on the motherboard is plugged in.
6.5 card is swiped, the gate is open, but the gate is not close. This situation is usually the
middle of the anti-pinch infrared is not right. Before fixing the chassis, you must determine
the infrared alignment to open the door normally. If there is no good infrared, after the
power is turned on, an alarm will be given. After swiping, please press the direction
indicator arrow to exercise.

7.Equipment operating manual


7.1 devices must function debug before put into use, be put into use after normal
debugging;
7.2 when the power device is prohibited to stand within the channel;
7.3 pedestrian read cartoons row, in the direction of the indicator flag is not turn green,
allowed to enter the channel;
7.4 pedestrians through the passage, do not prolonged stay in the intermediate channel;
7.5 do not crowded during through gateway, should maintain a certain distance between
people;
7.6 It is strictly forbidden to read the card and pass the gate quickly;
7.7 Conditions recommended identifies the native pass device in a conspicuous place of
work, the safe and orderly passage of the person by guiding gates channel;
7.8. The equipment should be properly managed when it is not working. It is strictly
forbidden to knock or shake the equipment;
7.9 When the device is in a closed state, non-impact force or sliding gates;

! warning:
1. Do not use the unit when there is lightning, to prevent
damage to the unit ;
2. Make sure that the system is securely connected to prevent
personal injury;

Vous aimerez peut-être aussi