1.equipment introduction
1.1 introduction
Intelligent channel gate is an intelligent channel management equipment developed
and produced by our company after many years of development. The device integrates
mechanical, electronic, microprocessor control and various reading and writing
technologies. Through the configuration of various reading and writing devices, the use
of reliable security protection devices and real-time alarm system and direction
indication interface, coordinate the intelligent control and management of the channel.
The shape is stamped and formed by stainless steel plate. It is beautiful in appearance,
rust-proof and durable. It adopts standard electrical interface and can easily integrate bar-
code reader, ID card, IC card and other card readers on the device to provide civilization
for the inbound and outbound personnel. The orderly way of passing, at the same time can
prevent illegal personnel from entering and exiting; in addition, the system also specially
designed to meet the requirements of fire protection requirements, in the event of an
emergency, to ensure that the passage is unimpeded and convenient for personnel to
evacuate in time.
1.2. Features
1) The main device of the device adopts automotive grade chip, and the rest of the
devices adopt industrial grade device to ensure stable operation of the system;
2) The whole process of detecting the operation status of the gate to ensure the
safety of pedestrians;
3) The movement structure adopts 24V DC brushless motor + encoder technology;
4) Anti-collision and anti-pinch function;
5) With zero self-test function, it is convenient for users to maintain and use;
6) Illegal intrusion, reverse traffic, trailing alarm function;
7) With automatic reset function, if the pedestrian reads the valid card, if the system
does not pass within the specified time, the system will automatically cancel the
pedestrian access right;
8) Unified standard external electrical interface, which can be connected with a
variety of card readers, and can be remotely controlled and managed through a
management computer;
9 ) The whole system runs smoothly, with low noise, and the noise index is less than
55 decibels;
10 ) The service life is more than 5 million times.
1.3 specification
1) Product size: 1500*300*1000mm
2) Box material: SUS304/1.5mm
3) Power supply voltage: AC220±10% V, 50HZ
1
4) Drive motor: DC motor 24 V/70W
5) Working environment temperature: -15 O C - 70 O C
6) Relative humidity: relative humidity ≤ 90% , no condensation
7) Input interface: 12V level signal or pulse width> 12V drive current
pulse of 100 ms> 10 mA
8) Communication interface: TCP/IP network interface
9) Channel width: 550MM
10) Passing speed: 35 people / minute
11) One-way switching time: 0.5 seconds
2.housing dimension
2.1 housing dimension
2
reading and writing device, an infrared sensor, etc.; the movement consists mainly of a
motor, a frame, a drive shaft, a gate.
The electronic control system consists of a card reader, a main control board, an
infrared sensor, a direction indicator, an alarm, a limit switch, and a transformer.
Card reader (self-prepared): After reading the information on the card and after judging the
processing, it sends an application pass signal (switch signal) to the main control board.
Main control board: The control center of the system, which receives the signals of the card
reader and the infrared sensor, and performs logical judgment and processing on these
signals, and then issues an execution command to the direction indicator, the motor, the
counter, and the alarm. Infrared sensor: detects pedestrian position and plays a safety
role;Direction indicator: displays the current status of the channel and guides pedestrians
through the channel in a safe and orderly manner.
Alarm: When the system detects a pedestrian who has illegally entered the channel, it will
give an alarm prompt.
3
an alarm will be issued until the pedestrian exits the channel. Release the
alarm; re-read the valid card to allow access ;
Remarks:
1. The two gates form a channel, the control board, the movement controller, and
the three-core infrared (receiving end) are the main unit. Only the movement controller and
the two-core infrared (transmitting end) are auxiliary machines.
4.4.install dimension(mm ):
4.4. Installation dimensions (unit: mm):
4
Please connect the cable correctly. If there is a door panel, you need to connect the
head cable on the slave to the access panel through the cable. Then connect the power cable
to the air switch and turnon the power switch. Run to the off state, please do not stand
within the range of gate operation at this time).
4.5. Description of the connection between the control board (host) and
the movement controller (slave)
4.5.1, the host side, there is a marked positive (FIG. A) on a drive plate connected to a
power supply 1, labeled 2 is then negative, then CANL 3 is marked, the marked contact
CANL 4.
4 .5.2, slave side, is marked with a positive (FIG. B) on the drive plate connected to the
power supply 1 is marked with the negative electrode 2 is connected, then CANL 3 is
marked, the marked contact CANL 4.
5
Warning :
1. The depth of the buried PVC pipe should be greater than 60 mm , the exposed ground
height should be greater than 50 mm , and the exit bends back to prevent the pipe from
entering the water.
2. When installing the channel gate, the left and right gates of each channel should be
aligned;
3. Connect the system protection ground wire;
4. If the equipment is used outdoors, a cement platform with a height
of 100 ~ 200mm should be built at the installation site to protect the tide, and a sunscreen
and rainproof facilities such as a ceiling should be added;
5. After the equipment is installed, the status check and function debugging are
qualified before it can be put into normal use.
After the device status check is normal, the following functions can be debugged!
6
number is increased by 1 , and the DEC key is reduced by 1 ; there are 15 function
settings, respectively:
P00 : Exit the menu setting function. When P00 appears , press the SET button to exit the
menu setting;
P01 : Running direction when the motor is powered on, =000 : forward rotation when
power is on, =001 reverse when powering up. (factory is 001 )
P02 : The maximum running time of the gate, the unit is 0.1 second. If the time is set
to 60, that is, 6 seconds, the gate will stop closing when the gate is not closed for 6 seconds
(the system default is 60 )
P03: pedestrians time, in seconds, so 10 is the time to 10 seconds after passing pedestrians
credit card is not canceled within a set time the card. (The system default is 10 )
P04 : Working mode (system default is 000 )
=000 : two-way swipe
=001 : Inward swipe, free to go
=002 : Freedom of movement, outgoing card
=003 : Freedom of movement, freedom of movement
=004 : Opening the gate (one way)
=005 : Outbound opening (one way)
P05 : Speed of opening the door: the speed at which the gate is closed from the position to
the position in the forward direction. (The system default is 10 )
P06 : Forward closing speed: the speed at which the gate moves from the forward to the
closed position. (The system default is 10 )
P07 : Outward opening speed: the speed at which the gate is closed from the position to the
out position. (The system default is 10 )
P08 : Outbound closing speed: the speed at which the gate moves from the out to the
position to the off position. (The system default is 10 )
P09 : The pedestrian transit interval is considered to be one person within the set time (the
system default is 10 )
P10 : The forward counter is cleared. When the P10 is displayed , press the SET button to
display C — L . After pressing the INC button, the system sends a forward count clear
signal and the feed counter is cleared.
P11 : The outbound counter is cleared. When the P11 is displayed , press the SET button to
display C — L . After pressing the INC button, the system will send a count clear signal
and the outbound counter will be cleared.
P12 : With memory / without memory setting (system default is 000 )
=000 : two-way with memory,
=001 : There is no memory in the heading and memory in the out direction.
=002 : The memory is in the forward direction, and the memory is in the outgoing
direction.
=003 : Two-way without memory.
P13 : The device communication address, that is, the number of
machines. Range 1 — 255 . (The system default is 001 )
7
P14 : device type
P15 : The system restores the default value. When P is displayed , press SET to
display P — 2 Press INC now.
The key system restores the default value.
P16: The door opening direction is adjusted when the communication is opened. When =0,
it is in one direction, and when it is 1, it is in the opposite direction. In order to ensure that
the two gates of the same channel are in the same direction, the side is set to 0 and the side
is set to 1.
P17: How long does it take for the pedestrian to turn off after passing the system? There is
no delay when the gate is normal. If the gate
When it is long, the pedestrian will immediately close the door and then hit the pedestrian
to adjust the delay to avoid it.
2. Exit the menu setting: Press the INC key or the DEC key. When
the P00 character appears , press the SET key to exit the menu setting. (A smaller
value than the speed of the faster speed.)
Note: 1. Peripheral equipment must not be added to the system without permission;
2. If the debugging result is inconsistent with the function during debugging, please
refer to the section Common Faults and Troubleshooting.
8
6.4 flap gate is swiped, one is open and one is not open. Recheck that the sync cable is
connected. After ensuring the connection, the motherboard that cannot be opened has
received the signal of the opening. If not, recheck whether the wiring is dropped or not, and
whether the plug on the motherboard is plugged in.
6.5 card is swiped, the gate is open, but the gate is not close. This situation is usually the
middle of the anti-pinch infrared is not right. Before fixing the chassis, you must determine
the infrared alignment to open the door normally. If there is no good infrared, after the
power is turned on, an alarm will be given. After swiping, please press the direction
indicator arrow to exercise.
! warning:
1. Do not use the unit when there is lightning, to prevent
damage to the unit ;
2. Make sure that the system is securely connected to prevent
personal injury;