Diketahui Nilai data-data:


P 12.69 Bar
P(v) 14.17 bar
T 67 C
v 0.23 cst
ρ 488 kg/m³
µ 0.00011224 kg/m.s
Ɛ 0.046 mm
Inside Diameter (ID202.7 mm 0.00000023
A 0.0322535227 m²
L 26 m 0.112
V 1.0550096542 m/s
D1 154.1 schedule number 6" 0.2027
Re 9.30.E+05

dimana rumus yang digunakan untuk mendapat nilai Re diatas adalah:


𝑅�=𝐷��/𝜇�=𝑑��/𝜇=354 �/𝑑𝜇

lalu mencari nilai A digunakan persamaan dibawah ini:

�=(𝜀/𝑑" " )/3.7+(6.7/𝑅�)^0.9

sehingga menghasilkan nilai :

Ɛ/d 0.0002269364
� 0.7602368032
A 8.49.E-05

lalu mencari nilai fc, fd, dan deltaPbar/100m menggunakan persamaan dibawah ini:
1/√𝑓𝑐=−4 log 〖 [𝜀/3.7𝐷−5.02/𝑅� log�] 〗 〖∆�〗 _𝑏𝑎𝑟/100�=225𝑓��^2/𝑑^5
〖∆�〗 _𝑓=𝑓𝐷(�/𝐷)� �^2/2

sehingga menghasilkan nilai:

fc 3.76.E-03
fd 1.50.E-02
〖∆�〗 _𝑏𝑎𝑟/100� 0.0200946959 bar/100m

lalu melengkapi data-data dibawah ini dengan menggunakan persamaan:

�_𝑓=�_1/𝑅�+�_� [1+�_𝑑 (25.4/𝐷_(𝑛.��) )^0.3𝑅�<2500


� �^2/2 ]
�_𝑓=[0.6+0.48𝑓][(1−�^2)/�^4 ] [𝑠�𝑛(𝜃/2)]^(

�=𝐷_1/𝐷_2

ℎ𝑓=𝑓_𝐷 (�/𝐷) �^2/2�

sehingga menghasilkan nilai :

L/D 128.2683769117 〖∆�〗 _𝑓(𝑓�𝑡𝑡�𝑛�𝑠) =�_𝑡𝑜𝑡𝑎𝑙 (��^2


ρ v²/2 271.5830703922 N/m²
ΔP f 5.23.E+02 N/m²
ℎ_(𝑓(𝑓�𝑡𝑡�𝑛�))=�_𝑡𝑜𝑡𝑎𝑙 �^2/2�
hf 0.1093194523 m
Kf 0.4745889626

setelah itu menanmgngislengkapi tabel fitting /wajib


Fittings n K1 nK1
90° ell (r/D =1.5) 10 800 8000
Ball valve (β=1) 1 300 300
Gate Valve (β=1) 1 300 300
Tees (Flow thru bra 1 800 800
Reducer 1
Square edged inlet KK = 0.5
Total

Sehingga mendapatkan data seperti ini:

∆Pf(fitting) 1059.9887237407 N/m²


hf (fittings) 0.2214177411 m
∆Pf(total) 1.58.E+03 N/m²
h total 0.3307371935 m
ef 3.2445318678 m²/s²
(-)∆P -31927.6284485121 bar
A 0.0186412459 m²
v 1.8254025536 m/s
Re 1223513.81090765 (fully turbulent)
𝜀/𝑑 0.0002985075
A 9.9069285044944E-05
1/fc^1/2 16.0510139109
fc 0.0038814595
fd 0.015525838
∆P bar/100 m 0.0817764123 bar/100 m
L/D 0
� �^2/2 813.0310538193 N/m²

∆Pf 0 N/m²
0 kN/m²
hf 0m

Setelah itu melengkapi data-data kiriman :

Fitting n K1 nK1
45° ell(r/D=1.5) 6 500 3000
90° ell(r/D=1.5) 40 800 32000
Ball valve (β=1) 6 300 1800
Globe valve (β=1) 1 1500 1500
Check valve 2 1500 3000
Lift check valve 3 2000 6000
No exit loss, if discharge is above
liquid in the column
Total

Setelah itu melengkapi data-data kiriman :

∆Pf (fittings) 38296.2017280521 N/m² 38.2962017281


hf (fittings) 7.9995742317 m
∆Pf Total 38.2962017281 KN/m² 0.3829620173
h Total 7.9995742317 m
ef 78.4758232132 m²/s²
∆z 43 m
(-∆P) 244149.241728052 N/m² 2.4414924173
TUGAS PAP (SELASA PAGI) KELOMPOK 4

Data-data lainnya:
LPG flow rate =
Pipe size D 8 in
Sch 40
Pipe Length 19 m
Pipe elevation,delta z 7 m
m2/s

cP

m
�^2)/�^4 ] [𝑠�𝑛(𝜃/2)]^(1/2)

�𝑡𝑡�𝑛�𝑠) =�_𝑡𝑜𝑡𝑎𝑙 (��^2)/2


�+�_1/��+�_1+�_1/2�=�_2/��+�_2+(�_2^2)/2�+ef+w
𝑡�𝑛�))=�_𝑡𝑜𝑡𝑎𝑙 �^2/2�

Ki nKi Kd Kf
0.071 0.71 4.2 2.317
0.017 0.017 4 0.054
0.037 0.037 3.9 0.115
0.14 0.14 4 0.441
0.476
0.5
3.903
Ki nki Kd Kf
0.052 0.312 4 1.044
0.071 2.84 4.2 9.834
0.017 0.102 4 0.342
1.7 1.7 3.6 5.276
0.46 0.92 4 3.072
2.85 8.55 3.8 27.535
0

47.103

KN/m2 0.382962 bar


Vessel pressure
bar Static-head pressure
Friction loss
∆P Total

bar
1432.24 ton/day 122.5 m3/h 59780
Discharge (barg)
16.59
2.058
0.489
19.137
kg/h