Radiation Convection
Heat absorbed kcal/hr 4.9x10^6 1.6x10^6
Area sqmt 85 165
Heat flux kcal/sqmt h 57700 9700
No of parallel branch no 11 11
Pipe type cylindrical coil
Coil mean diameter mm 2700 < 2700
Pipe od mm 76.1 76.1
Pipe wall mm 4.5 4.5
Pipe length mm 13700 continuous
MOC st 35.8 I st 35.8 I
Hold up volume cum 5.4
Operation pressure bar 16 16
Product outlet temp degc 350
Design temp degc 400 400
Test pressure bar 21 21
Del p bar 1.5
Heat transfer coefficient inlet kcal/hr sq mt deg c 2500 2500
Heat transfer coefficient outlet kcal/hr sq mt deg c 33.6
Overall heat transfer coefficient kcal/hr sq mt deg c 25.5
Outlet temp normal deg c 320
Outlet temp max deg c 340
Pipe header material st 35.8 i st 35.8 i
Combustion chamber load kcal/cum hr 1,90,000
Flue gas inlet temp deg c 1300 945
Flue gas outlet temp deg c 945 485
BURNER
Model AR-45
QTY 1
Area 204 sq mt
Radiation Convection
Heat absorbed kcal/hr 4.9x10^6 1.6x10^6
Area sqmt 85 165
Heat flux kcal/sqmt h 57700 9700
No of parallel branch no 11 11
Pipe type cylindrical coil
Coil mean diameter mm 2700 < 2700
Pipe od mm 76.1 76.1
Pipe wall mm 4.5 4.5
Pipe length mm 13700 continuous
MOC st 35.8 I st 35.8 I
Hold up volume cum 5.4
Operation pressure bar 16 16
Product outlet temp degc 350
Design temp degc 400 400
Test pressure bar 21 21
Del p bar 1.5
Heat transfer coefficient inlet kcal/hr sq mt deg c 2500 2500
Heat transfer coefficient outlet kcal/hr sq mt deg c 33.6
Overall heat transfer coefficient kcal/hr sq mt deg c 25.5
Outlet temp normal deg c 320
Outlet temp max deg c 340
Pipe header material st 35.8 i st 35.8 i
Combustion chamber load kcal/cum hr 1,90,000
Flue gas inlet temp deg c 1300 945
Flue gas outlet temp deg c 945 485
BURNER
Model AR-45
QTY 1
Area 204 sq mt
Chimney as optional
scope of Vendor
Curculation
Filter pump