Vous êtes sur la page 1sur 2

PREDIMENCIONAMIENTO DE COLUMNAS ACI

Columnas Centrales
�=𝑁/(0.45∗𝑓^′ 𝑐)

Columnas Esquineras y Medianeras


�=𝑁/(0.35∗𝑓^′ 𝑐)
N: Carga Axial en la columna
f'c: Resistencia de diseño del hormigon a los 28 dias

f'c= 210 [kg/cm2]

Planta baja
CALCULO TEORICO ADOPTAR
CARGA AREA ACI a D b
COLUMNA POSICION
[t] [cm ]2
[cm] [cm] [cm]
PB A-5 Central 31.00 328.04 18.11 20.44 25
1º A-6 Central 23.00 243.39 15.60 17.60 25
2º A-7 Central 15.00 158.73 12.60 14.22 25
3º A-8 Central 7.00 74.07 8.61 9.71 20
4º A-9 Central 2.00 21.16 4.60 5.19 20
5º Central 1.00 10.58 3.25 3.67 20
191.30 2602.65 51.02 57.57 20
205.44 2795.10 52.87 59.66 20
115.56 1572.23 39.65 44.74 20
102.51 1394.65 37.35 42.14 20
143.65 1520.15 38.99 43.99 20
189.31 2003.26 44.76 50.50 20
210.70 2229.60 47.22 53.28 20
116.12 1228.78 35.05 39.55 20
102.07 1080.11 32.86 37.08 20
57.21 605.43 24.61 27.76 20
113.07 1196.54 34.59 39.03 20
103.44 1094.62 33.09 37.33 20
82.78 875.98 29.60 33.40 20
49.53 524.07 22.89 25.83 20

º
OLUMNAS ACI

o del hormigon a los 28 dias

ADOPTAR
h D Prueva
[cm] [cm] [cm2]
25 25 625 ok
25 26 625 ok
25 27 625 ok
20 28 400 ok
20 29 400 ok
20 30 400 ok
20 30 400 Aumentar seccion
20 30 400 Aumentar seccion
20 30 400 Aumentar seccion
20 30 400 Aumentar seccion
20 30 400 Aumentar seccion
20 30 400 Aumentar seccion
20 30 400 Aumentar seccion
20 30 400
20 30 400
20 30 400
20 30 400
20 30 400
20 30 400
20 30 400