Digital Multimeters

ts of
our extensive range of digital multimeters. Designed to help you do your
ciently and with greater accuracy, there is a model for
every budget and application. Choose from handheld troubleshooters to
ultra smart instruments packed with features, including the ability to log
and graph data, as well as high-precision bench units.
280 Series Digital Multimeters

Advanced diagnostic and logging


functionality for maximizing productivity
Replacing the popular 180 Series, the • Logging function with TrendCapture for
Fluke 289 and Fluke 287 represent the easy review of logged data
next generation of high-performance • Multiple readings per display provide
industrial logging multimeters, more information at a glance
including higher accuracy and greater • “I”-info button for convenient on-board
troubleshooting convenience than ever help
before. With the ability to log data and • PC interface for easy data transfer
review it graphically on the large display,
you can solve problems faster and help In addition, the Fluke 289 provides:
minimize downtime, while working at • Lo pass filter for motor drive
several locations. measurements
• LoZ – Low impedance function prevents
• Large 50,000 count 320 x 240 (1/4 VGA) false “ghost voltage” readings
dot matrix display • 50 Ω range for motor winding and low
ohm measurements

Fluke 289 Features


287 289
True-RMS measurements AC, AC+DC AC, AC+DC
B a n d w i d t h ( v o l t a ge / c u r r e n t ) 100 k H z / 100 k H z 100 k H z / 100 k H z
D i gi t a l d i s p l a y c o u n t s ( d e f a u l t / s e l e c t a b l e ) 50. 000 / 50. 000 50. 000 / 50. 000
Fluke 287
Logging function with TrendCapture
Records events and trends
Internal memory Up to 180 h Up to 180 h
Saves measurements
Optical USB PC communications interface
Low input impedance function (LoZ)
Motor winding and low ohm measurement range 50 Ω
Low pass filter
Field upgradeable/expandable meter
Navigation keys
F1-F4 soft keys/user function menus
I-info button/on board help screens
Multilingual interface
Precise performance View logged data graphically
Saves preferred measurement setups
on screen
Current measurement: 20 A (30 seconds momentary; 10 A continuous)
Peak capture (records transients as fast as 250 µs)
Continuity measurement
Min/Max/Average with Time Stamp (records signal fluctuations)
IP Rating 54

Specifications
(Check the Fluke web for detailed specifications)
True RMS
F u n c ti o n s M ax im um M a x . r e s o l u ti o n 2 8 7 a n d 2 8 9 **
V o l t a ge D C 1000 V 1 µV ±( 0 . 0 2 5 % + 5 )
V o l t a ge A C 1000 V 1 µV ±( 0 . 4 % + 4 0 )
Included Accessories C u r r en t D C 10 A 0. 01 µ A ±( 0 . 1 5 % +2 )
TL71 silicone test leads, probe holder, 6 AA C u r r en t A C 10 A 0. 01 µ A ±( 0 . 7 % + 5 )
batteries (installed), user manual, Calibration T em per a tu r e - 2 0 0 ºC t o 1 3 5 0 ºC 0 . 1 ºC ±( 1 . 0 % + 1 º C )
Certificate Sheet. R es i s ta n ce 500 M Ω 0. 01 Ω ±( 0 . 0 5 % + 2 )
C on d u c ta n c e 50 n S 0. 01 n S ±( 1 . 0 % + 1 0 )

Ordering Information C a pa ci ta n ce
Fr eq u en cy
100 m F
1 MHz
0. 001 n F
0. 01 H z
±( 1 . 0 % + 5 )
±( 0 . 0 0 5 % + 1 )
Fluke 287 True-RMS Electronic logging
Accuracies are best accuracies for each function.
multimeter with TrendCapture ** 287 and 289 accuracy and resolution are stated for 50.000 counts
Fluke 289 True-RMS Industrial logging
Battery life: 50 hours minimum, Weight: 0,871 kg
multimeter with TrendCapture
180 hours in logging mode Lifetime warranty
Fluke 289/FVF Industrial logging multimeter
Size (HxWxD): 222 mm x 102 mm x 60 mm
and Software Combo Kit

Fluke 287/FVF FlukeView Forms Combo Kit


Recommended Accessories
FVF-SC2 FlukeView Forms software
including IR/USB cable

TLK289 TL910 TLK287 TPAK C280


233 Remote Display Multimeter

New
Ultimate flexibility with removable display
The NEW Fluke 233 remote display digital switch or an isolator switch. Wireless
multimeter allows you to be in two technology allows the display to be
places at once. The removable display carried up to 10 meters away from the
solves the problems of holding both point of measurement. The Fluke 233
the meter and the test leads to make a is also designed to work in areas where
measurement, making measurements the operator can’t be close to the active
in hard-to-reach places, and making measurement point, like clean rooms or
measurements in machines or panels hazardous areas.
that are physically separated from a limit
Features
233
Remo vable magnetic display

True-RMS measurement

Digital display counts 6000

Display backlight

Built in thermometer

Resistance, continuity and diode test

Min/Max and average recording

Auto power off maximizes battery life

Radio transmitter automatically turns off when


the display is connected to the meter

Use as conventional multimeter when the display is connected

Safety rating CAT IV 600 V / CAT III 1000 V

Auto and manual ranging


Fluke 233
Display Hold and AutoHOLD ®

Unsafe voltage alert warns for voltages above 30V

2 Low batteries indication

Ergonomic case with integrated holster

Selectable sleep mode preserves battery life

S p e c ifications
On all inputs
Fluke 233
Functions
Maximum Max. Resolution Accuracy
V o l t a ge D C 1000 V 0. 1 m V ±( 0 . 2 5 % + 2 )
True RMS
V o l t a ge A C 1000 V 0. 1 m V ±( 1 . 0 % + 3 )
C u r r en t D C 10 A 1 mA ±( 1 . 0 % + 3 )
C u r r en t A C 10 A 1 mA ±( 1 . 5 % + 3 )
R es i s ta n ce 40 M Ω 0. 1 Ω
Included Accessories
Test leads with 4mm lantern tips and Fr eq u en cy 50. 00 k H z 0. 01 H z
protective cap, AC 72 alligator clips, 80BK-A T em per a tu r e - 4 0 º C t o +4 0 0 º C
temperature probe, CD-ROM, AA batteries and Wireless frequency: 2.4 GHz ISM Band 10 meter range
user manual. Accuracies are best accuracies for each function

Ordering Information
Fluke 233 Remote Display Multimeter
Battery Life: AA alkaline (3 for main body, Weight: 0.6 kg
2 for display), 400 hrs typical Three year warranty
Size (HxWxD): 193 x 93 x 53 mm

Recommended Accessories

80AK-A 80PK-9 i410 Tpak C35


80 Series V
Digital Multimeters

Performance and accuracy for


maximum industrial productivity
The Fluke 80 Series V have improved The Fluke 87V has a unique function
measurement functions, troubleshooting for accurate voltage and frequency
features, resolution and accuracy to solve measurements on adjustable speed
more problems on motor drives, in plant motor drives and other electrically noisy
automation, power distribution, and equipment. A built-in thermometer
electro-mechanical equipment. conveniently allows you to take
temperature readings without having to
carry a separate instrument. For 87V Ex
see also page 106 and 107.
Features
83V 87V / 87V Ex
True-RMS voltage and current for accurate
measurements on non linear signals
B a n d w i d t h ( v o l t a ge / c u r r e n t ) 5 kHz 20 k H z

Fluke 83V D i gi t a l d i s p l a y c o u n t s ( d e f a u l t / s e l e c t a b l e ) 6000 20000 / 6000

Selectable filter for accurate voltage and frequency


measurements on motor drives
Large display with analog bargraph and 2 level bright
white backlight
Auto and manual ranging for maximum flexibility

Built-in thermometer lets you carry one less tool

Peak capture to record transients as fast as 250 µs

Relative mode to remove test lead resistance from low


Fluke 87V ohms measurements
Min-Max-Average recording with Min/Max Alert to
capture variations automatically
AutoHOLD® to capture stable readings avoiding noisy
signals
Audible continuity, diode test and duty cycle

Input Alert

“Classic” design with new remo vable holster with built


in test lead and probe storage
83V/87V Improved selectable sleep mode for long battery life

Easy battery exchange without opening the complete


case
ATEX safety rating II 2 G Eex ia IIC T4 87V Ex

Specifi cations
Fluke 87V Ex
(Check the Fluke web for detailed specifications)
On all inputs
Functions Maximum Range 83V 87V/87V Ex*
Max.
Max. resolution Accuracy Accuracy
resolution
Voltage DC 1000 V 0.1 mV ±(0.1%+1) 10 µV ±(0.05%+1)
True RMS Voltage AC 1000 V 0.1 mV ±(0.5%+2) 10 µV ±(0.7%+2)
Current DC 10 A ** 0.1 µA ±(0.4%+2) 0.01 µA ±(0.2%+2)
not 87V Ex
Current AC 10 A ** 0.1 µA ±(1.2%+2) 0.01 µA ±(1.0%+2)
Resistance 50 MΩ 0.1 Ω ±(0.4%+1) 0.01 Ω ±(0.2%+1)
Included Accessories Conductance 60 nS 0.01 nS ±(1.0%+10) 0.001 nS ±(1.0%+10)
TL75 test leads, AC72 alligator clips, yellow Capacitance 9999 µF 0.01 nF ±(1.0%+2) 0.01 nF ±(1.0%+2)
holster (H80M excl. TPAK), 80BK temperature Frequency > 200 kHz 0.01 Hz ±(0.005%+1) 0.01 Hz ±(0.005%+1)
probe (87V only), 9 V battery (installed), T em per a tu r e - 2 0 0 t o 1 0 9 0 ºC - 0 . 1 ºC 1. 0%
CD-ROM (user’s manual and technical notes) 8 0 B K t e m p e r a t u r e p r o be - 4 0 t o 2 6 0 ºC - - 2 . 2 ºC o r 2 %
and operator’s guide. Accuracies are best accuracies for each function.
* 87V accuracy is stated for 6000 counts and resolution for 20000 counts
** 20 A up to 30 seconds
Ordering Information Battery Life: Over 400 hours typical (alkaline). Weight: 0.6 kg
Fluke 83V Multimeter Size (HxWxD): 83V/87V: Lifetime Warranty
Fluke 87V True RMS Multimeter 200 mm x 95 mm x 48 mm 87V Ex: One Year Warranty
Fluke 87V Ex Intrinsically safe
True RMS multimeter Recommended Accessories
Fluke 87V/E2 Industrial Electrician Combo

C25 TL238 i410/i1010 TPAK L215


170 Series Digital Multimeters

Versatile meters for field service or


bench repair
These meters have the features needed
to find most electrical, electro-
mechanical and heating and ventilation
problems.
They are simple to use and have
signifncant improvements over Fluke’s
original 70 Series like True-RMS, more
measurement functions, conformance to
the latest safety standards, and a much
larger display that’s easier to view.
Features
175 177 179
T r u e- R M S m ea s u r em en ts AC AC AC

Digital display counts, updates 4 times per secon 6000 6000 6000

Display backlight
Fluke 177
Analog bargraph / 33 segments, updates 40 times per
second
Auto and Manual ranging

Display Hold and AutoHOLD®

Min-Max-Average recording mode with Min/Max Alert

Temperature readings (bead thermocouple probe


included)
Smoothing mode allows filtering of rapidly changing
Fluke 179 inputs
Audible continuity and diode test

Test lead alert

Unsafe voltage alert warns for voltages above 30V

Low battery indication


Fluke 175
Ergonomic case with integrated holster

Easy battery and fuse exchange without opening the


complete case
Selectable sleep mode preserves battery life

Specifi cations
On all inputs
(Check the Fluke web for detailed specifications)

True RMS Functions Maximum Max. resolution 175 177 179


Voltage DC 1000 V 0.1 mV ±(0.15%+2) ±(0.09%+2) ±(0.09%+2)
Voltage AC 1000 V 0.1 mV ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)
Current DC 10 A 0.01 mA ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)
Included Accessories Current AC 10 A 0.01 mA ±(1.5%+3) ±(1.5%+3) ±(1.5%+3)
Resistance 50 MΩ 0.1 Ω ±(0.9%+1) ±(0.9%+1) ±(0.9%+1)
Test leads with 4 mm lantern tips and
Capacitance 10000 µF 1 nF ±(1.2%+2) ±(1.2%+2) ±(1.2%+2)
protective cap, installed 9V battery and users
Frequency 100 kHz 0.01 Hz ±(0.1%+1) ±(0.1%+1) ±(0.1%+1)
manual. The 179 also includes the 80BK Temperature -40 ºC/+400 ºC 0.1 ºC ±(1.0%+10)
temperature probe.
Accuracies are best accuracies for each function

Ordering Information Battery Life: Alkaline, 200 hrs typical Weight: 0.42 kg
Fluke 175 True RMS Multimeter Size (HxWxD): 190 mm x 85 mm x 45 mm Lifetime Warranty
Fluke 177 True RMS Multimeter
Fluke 179 True RMS Multimeter
Fluke 179/EDA2 Kit Electronics Combo Kit
Fluke 179/MAG2 Kit Industrial Combo Kit
Recommended Accessories

i400 C90 TLK-220 SV225 i410-i1010


110 Series Digital Multimeters

Compact design for ergonomic


one-handed operation
ve true-rms Fluke 115 Field Service Testing
c users. The compact Multimeter
instruments offer convenient one-handed An everyday multimeter for technicians, the
operation and a backlit display with large, easy- 115 is for electrical and electronic testing in
to-read digits. eld service, industrial, and applications where
more than the basic functions simplify work.
Fluke 117 Electrician’s Multimeter with
Non-Contact Voltage Fluke 114 Electrical Multimeter
The 117 is for electricians working in The 114 is for electrical troubleshooting and
commercial and non-commercial premises straightforward ‘go/no-go’ in residential/
(like hospitals and schools). It includes extras commercial testing. It has all the basic
like non-contact voltage detection for faster functions plus a special feature to prevent false
and safer operation. readings caused by ghost voltage.
Fluke 115
Fluke 116 Multimeter with Temperature Fluke 113 Multimeter
and Microamps The 113 is for basic electrical tests and
The 116 is for heating, ventilation and air repairing most electrical problems. Features
conditioning (HVAC) engineers. It includes include Fluke’s VCHEK™, added measurement
temperature measurement and microamp functions, backlight and conformance to the
current ranges to quickly troubleshoot HVAC latest safety standards.
Fluke 117
problems.
Features
113 114 115 116 117
True RMS readings AC AC AC AC AC
Counts 6000 6000 6000 6000 6000
Fluke 114
Backlight

Analog bargraph

AutoVolt: Automatic AC/DC voltage selection

VoltAlert™, Non-contact voltage detection

Built-in thermometer for HVAC applications

LoZ: low input impedance to prevent ghost voltage


VCHEK™ LoZ low impedance measurement function to
simultaneously test for voltage or continuity
Min/Max/Average to record signal fluctuations

Resistance, continuity

Frequency, Capacitance, Diode test -/ /


Microamps to test flame sensors

Display hold

Fluke 116 Auto/manual ranging

Low battery indication

Compact case with remo vable holster

Specifi cations
(Check the Fluke web for detailed specifications)
Functions Maximum Max. resolution 113 114 115 116 117
Fluke 113 Voltage DC 600V 1mV ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2)

On all inputs Voltage AC 600V 1mV ±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)


Current DC 10.00A 1mA ±(1.0%+3) ±(1.0%+3)
Current AC 10.00A 0.01A ±(1.5%+3) ±(1.5%+3)
True RMS
Resistance 40MΩ (113: 60KΩ) 0.1Ω ±(0.9%+2) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1)
Capacitance 10000µF 1nF ±(1.9%+2) ±(1.9%+2) ±(1.9%+2) ±(1.9%+2)
Frequency 50kHz 0.01Hz ±(0.1%+2) ±(0.1%+2) ±(0.1%+2)
Included Accessories Temperature -40°C/+400°C 0.1°C ±(1.0%+2)
Test leads with 4 mm lantern tips and VCHEK™ 600.0V AC/DC 0.1V ±(2.0%+3)
protective cap, holster, installed 9V battery
and users manual Accuracies are best accuracies for each function

Battery type: 9 volt Alkaline, 400 hours typical Weight: 0.55 kg (including batteries)
Ordering Information Size (HxWxD): 167 mm x 84mm x 46 mm Three Year Warranty
Fluke 113 True RMS Multimeter
Fluke 114 True RMS Multimeter
Fluke 115 True RMS Multimeter Recommended Accessories
Fluke 116 True RMS Multimeter
Fluke 117 True RMS Multimeter
Fluke 117/322 Kit Electricians Combo Kit

C50 TL223 MC6 TPAK


77IV Digital Multimeter

Versatile multimeter for field service


or bench repair
The 77-IV digital multimeter has the
features needed to repair most electrical
and electronic problems. This meter
cant
improvements over Fluke’s original
70 Series with more measurement
functions, conformance to the latest
safety standards, and a much larger
display that’s easier to view.

Features
77 IV
Digital display counts 6000
Large display with backlight
Min-Max-Average recording mode with Min/Max Alert
High contrast digital display with large digits
Analog bargraph/segments 31
Auto and Manual ranging
Automatic Touch Hold®
Audible continuity / diode test
Ergonomic case with integrated holster
Sleep Mode preserves battery life
EN 61010-1 safety rating CAT IV 600 V / CAT III 1000 V

Fluke 77 IV

Specifi cations
Function Maximum Max. resolution Accurancy
V o l t a ge D C 1000 V 1 mV ±( 0 . 3 % +1 )
V o l t a ge A C 1000 V 1 mV ±( 2 . 0 % +2 )
C u r r en t D C 10 A 0. 01 m A ±( 1 . 5 % +2 )
C u r r en t A C 10 A 0. 01 m A ±( 2 . 5 % +2 )
R es i s ta n ce 50 M Ω 0. 1 Ω ±( 0 . 5 % +1 )
C a pa ci ta n ce 9999 µ F 1 nF ±( 1 . 2 % +2 )
Frequency 99.99 kHz 0.01 Hz ±(0.1%+1)
Accuracies are best accuracies for each function.

Battery Life: 400 hours typical Weight: 0.42 kg


Size (HxWxD): 185 mm x 90 mm x 43 mm Lifetime Warranty

On all inputs

Included Accessories Recommended Accessories


TL75 test leads, operator’s manual, 9V battery
(installed)

Ordering Information
Fluke 77IV Multimeter i400 C35 Tpak TL225 TLK-225
27II / 28II Rugged IP67 Industrial
Multimeters

Designed to survive water, dust and rough


New handling and yet troubleshoot most electrical
problems
The NEW Fluke 27 II and 28 II digital load switching and faults on industrial
ne a new standard for circuits and complies with second edition
operating in harsh conditions with the IEC and ANSI electrical safety standards.
features and accuracy to troubleshoot Furthermore, the 28 II has a unique
most electrical problems. Both meters function for accurate voltage and
have IP 67 (waterproof and dustproof) frequency measurements on adjustable
rating, MSHA approvals (pending), speed motor drives and other electrically
extended operating temperature range noisy equipment.
of -15° C to + 55°C and 95% humidity, The new Fluke 20 series multimeters
and a 3-meter drop. They withstand are built to work in the toughest
hazardous 8.000 volt spikes caused by environments.

Features
27 I I 28 I I
IP 67 waterproof & dustproof protection

Withstands 3 meter drop (with holster)

True-RMS measurements
Fluke 27 II
D i gi t a l d i s p l a y c o u n t s 6000 2 0 0 0 0 /6 0 0 0

Bright, two-level backlight

Backlit keypad buttons

Reversible, rubber holster

Built-in thermometer

Resistance, continuity and diode test

Min/Max and average recording

Improved sleep mode for long battery life

Relative mode to remove test lead resistance


from low ohms measurements

Auto and manual ranging

S a f ety r a ti n g C AT I I I 1000 V CAT III 1000 V


CAT IV 600 V CAT IV 600 V

True RMS S p e c ifications


Max.
F u n c ti o n s M ax im um 27 II 28 II
Fluke 28 II Resolution
V o l t a ge D C 1000 V 0. 1 m V ±( 0 . 1 % + 1 ) ±( 0 . 0 5 % + 1 )
V o l t a ge A C 1000 V 0. 1 m V ±( 0 . 5 % + 3 ) ±( 0 . 7 % + 4 )

Temperature -200 ºC to
+1090 ºC
Resistance 0.1 Ω to 50 MΩ
L ow p a s s f i l t e r (M e a s u r e m e n t o n V S D ’s ) y es
Capacitance
On all inputs
Frequency 0.5 Hz to 199.99 kHz
Peak transient capture
Accuracies are best accuracies for each function

Battery Life: 3x AA alkaline, 800 hrs typical Weight: 0.75 kg


Size (HxWxD): 198 x 100 x 63.5 mm Lifetime Warranty
Included Accessories
TL 75 Test leads, AC 72 alligator clips, 80BK-A
temperature probe (28 II), holster, manual, Recommended Accessories
CD-ROM, three AA batteries (installed)

Ordering Information
Fluke 27 II IP 67 Industrial Multimeter
Fluke 28 II IP 67 True-RMS Industrial Multimeter PV 350 i200 i410 80K-6
88V Automotive Meter

The right meter for auto-electric diagnosis


Perhaps the most important tool you’ll
use in troubleshooting auto electrical
systems is the multimeter. Basic
multimeters measure voltage, current
and resistance, while automotive
multimeters like the Fluke 88V have
features that can check frequency, duty
cycle, make diode tests, and measure
temperature, pressure and vacuum.
Features
88V/A
Continuity for detecting open and shorts

Frequency for “pulsed-DC” and AC tests

Duty cycle to verify operation of feedback carburetors

Diode test for alternator testing

Built-in thermometer; thermocouple probe included

Min/Max/Average recording with Min/Max Alert

Peak capture to record transients as fast as 250 µs


Fluke 88V/A
Relative mode to remove test lead resistance from low ohms measurements

Millisecond pulse width measurements for fuel injectors

AutoHOLD® to capture stable readings

Large display with bright, two-level backlight

Magnet hanger to attach meter to the vehicle

RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions

Hard Meter Case

Safety rating CAT III 1000 V,


CAT IV 600 V

Specifi cations
On al inputs Fluke 88V
Range Resolution Accuracy
V o l t a ge D C 1000V 0. 1m V 0. 1%
V o l t a ge A C 1 0 0 0 V (5 k H z ) 0. 1m V 0. 5%
C u r r en t D C 10A 0. 1µ A 0. 4%
C u r r en t A C 10A 0. 1µ A 1. 2%
R es i s ta n ce 50M Ω 0. 1Ω 0. 4%
C a pa ci ta n ce 10m F 0. 01n F 1%
Included Accessories Fr eq u en cy 200k H z 0. 01H z 0. 005%
H80M Holster with TPAK Meter Hanging T em per a tu r e 1 0 9 0 ºC 0 . 1 ºC 1%
Solution, TL224 SureGrip Silicone Test Lead
Set, TP220 SureGrip Test Probe Set, AC285
SureGrip Large Jaw Alligator Clip Set, 80BK Battery Life: 88V – Over 400 hours typical Weight: 88V – 0.36 kg
Integrated Temperature Probe, RPM80 (alkaline) Lifetime Warranty
Inductive Pick-up Probe, C800 Hard Case, Size (HxWxD): 88V – 186 mm x 86 mm x 32 mm
User’s Manual + Quick Reference Guide

Ordering Information
Fluke 88V/A Automotive Meter Combo Kit
Recommended Accessories

TL82 TLK-282 90i-610s 80PK-27 (requires 80AK) PV350


8845A/8846A
6.5 Digit Precision Multimeters

Precision and versatility for bench or


systems applications
The Fluke 8845A and 8846A, 6.5 digit Perform 4-wire measurements easily
precision multimeters have the precision with two leads: Patented split terminal
and versatility to handle your most jacks for 2x4 Ohms function allows you
demanding measurements on the bench to perform precise 4-wire measurements
or in a system. with only two leads instead of four.
Optional Kelvin leads accessories are
Dual Display offers versatile graphical available to enable you to establish a 4-
Fluke 8845A capabilities: The 8845A and 8846A wire connection even in tight spaces.
features a unique graphical display that Systems Capabilities: Both instruments
can reveal signal quality issues like drift, include an RS-232, IEEE-488 and Ethernet
intermittent and stability by viewing interface as standard, with popular
the measurement data as a real time DMM emulation modes makes systems
TrendPlot™, Histogram or Statistics integration a simple task.
using the unique analyze mode. Software: Transfer data points from your
Wide Measurement Ranges: Resistance meter to your PC with the free copy of
or current has been extended to cover FlukeView Forms Basic. To customize
the widest range possible. your forms upgrade with FVF-UG.

Fluke 8846A

Features
8845A 8846A
Display Dual VFD Dot Matrix
Resolution 6.5 Digits
Measurement Rate (Rdgs/s) 1000
Use the built-in TrendPlot paperless chart recorder to Continuity / Diode Test Yes
graphically identify the extent of drift and intermittent Analytical Functions Statistics, Histogram, TrendPlot™, Limit Compare
events in analog circuits Math Functions NULL, Min/Max, dB/dBm
USB Device Port – U S B M em or y D r i v e p or t
Real Time Clock – Y es
Interfaces RS232, IEEE-488.2, Ethernet
Programming Languages/ SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
Emulation Modes
S a f ety D e s i gn e d t o c o m p l y w i t h I E C 6 1 0 1 0 - 1 2 0 0 0 - 1 , A N S I / I S A - S 8 2 . 0 1 - 1 9 9 4 , C A N /
View results in Histogram mode to reveal stability or CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII
noise problems in analog circuits

Specifi cations
(Check the Fluke web for detailed specifications)

8845A 8846A
Handle even the most demanding measurements with Function* Range Resolution Accuracy* (%) Range Resolution Accuracy* (%)

high accuracy and 6.5 digit resolution Voltage DC 1000 V 100 nV 0.0035 1000 V 100 nV 0.0024
Voltage AC (Freq 300 Hz) 750 V 100 nV 0.06 1000 V 100 nV 0.06
Resistance (2x4 Wire) 100 MΩ 100 µΩ 0.01 1 GΩ 10 µΩ 0.01
Current DC 10 A 100 pA 0.05 10 A 100 pA 0.05
True RMS Current AC (Freq. 3Hz-10kHz) 10 A 10 µA 0.10 10 A 100 pA 0.10
Freq/Period 300 kHz 1 µHz 0.01 1 MHz 1 µHz 0.01
Capacitance - - - 1 nF to 0.1 F 1 pF 1
Temperature RTD - - - -200 to +600º 0.001º 0.06
Included Accessories * Accuracy =+/- (% of reading)
LCI Line Power Cord, TL71 Test Lead Set,
Spare Line Power fuse, Programmers Manual/ Size (HxWxD): 88 mm x 215 mm x 293 mm
User Manual on CD-ROM, 884X-USB USB to Weight: 3.6 kg
RS232 Cable Adapter, FVF-BASIC FlukeView Three Year Warranty
Forms Software Basic Version. Recommended Accessories
Ordering Information
Fluke 8845A 6.5 Digit Precision Multimeter
Fluke 8845A/SU 6.5 Digit Precision
Multimeter (software + cable)
Fluke 8846A 6.5 Digit Precision Multimeter 884X-case TL2X4W-TWZ TL2X4W-PT II 884X-512M FVF-UG
Fluke 8846A/SU 6.5 Digit Precision Hard case 2x4 Wire Ohms Tweezer
Test Leads
2x4 Wire Ohms Test
lead 2mm Probe Tip
USB Memory 512M FlukeView Forms
Software Upgrade
Multimeter (software + cable)
Calibration & Service agreements
8808A 5.5 Digit Multimeter

Versatile multimeter for manufacturing,


development and service applications
Manufacturing test, R&D, development Eliminate production mistakes: The
and service applications demand 8808A has a limit compare mode with
exibility from a built in display enunciators that clearly
bench meter. The Fluke 8808A delivers a show whether a test is within or out of
wide variety of measurement functions, limits.
including volts, ohms, and amps, plus
frequency - all at superior accuracy and Perform 4-wire measurements with
resolution with a basic V dc accuracy of only two leads: Patented split terminal
Fluke 8808A 0.015 %. jacks for 2x4 Ohms function allow you
to perform precise 4-wire low ohms
Measure sensitive leakage current: The measurements with only two leads
Fluke 8808A includes two low impedance instead of four. Optional test lead
low current ranges for measuring accessories are available to enable you
sensitive leakage currents (i-Leakage). to establish a 4-wire connection even in
tight spaces or on surface mount devices.
Perform routine manufacturing
functional tests with consistency:
Use setup keys (S1 – S6) for fast access to
repetitive measurements. Operators no
longer need to press multiple buttons to
The Fluke 8808A includes two low impedance low make routine measurements.
current ranges for measuring sensitive leakage
currents
Features
8808A
Display VFD multi segment
Resolution 5.5 digits
Measurements V ac, V dc, I dc, I ac, Ω, Cont, Diode
Advanced Measurements 2X4 Wire Ohms, Freq, i-Leakage
Continuity / Diode Test Yes
Analytical Functions Limit Compare
Math Functions dBm, dB, Min, Max
Interfaces RS-232, USB via optional adapter
Programming Languages/Modes Simplified ASCI, Fluke 45
Use setup keys (S1-S6) for fast access to repetitive
Safety Rating CAT I 1000 V, CAT II 600 V
measurements. Setups can include limit compare mode
with pass/fail indicators

Specifi cations
(Check the Fluke web for detailed specifications)

F u n c ti o n s R a n ge R e s o l u ti o n A c c u r a cy *
V o l t a ge D C 200 m V t o 1000 V 1 µV 0. 015
Voltage AC 200 m V t o 750 V 1 µV 0. 2
Dual Display (Freq. 10 Hz to 100 kHz)
R e s i s t a n c e (2 x 4 W i r e ) 200 Ω t o 100 M Ω 1 mΩ 0. 02

C u r r en t D C 200 µ A t o 10 A 1 nA 0. 02

Current AC 20 m A t o 10A 100 µ A 0. 3


True RMS (Freq. 20 Hz to 2 kHz)
F r e q . Pe r i o d 20 H z t o 1 M H z 0. 1 m H z 0. 01
(Freq. only)

Included Accessories * Accuracy = +/- (% of reading)

LCI Line Power Cord, TL71 Test Lead Set, Spare


Line Power fuse, 884X-USB USB to RS232 Cable Size (HxWxD): 88 mm x 217 mm x 297 mm
Adapter, FlukeView Forms Software Basic Weight: 2.1 kg
Version, Programmers Manual/User Manual Three year Warranty
on CD-ROM. Recommended Accessories

Ordering Information
Fluke 8808A 5.5 digit multimeter
Fluke 8808A/SU 5.5 digit multimeter,
(software & cable)
Fluke 8808A/TL 5.5 digit multimeter, TL2X4W-TWZ 884X-case TL2X4W-PT II 884X-short FVF-UG/SC4/SC5
2x4 Wire Ohms Tweezer Hard case 2x4 Wire Ohms Test 4-Wire Short FlukeView Forms
2X4W Test Lead Kit Test Leads lead 2mm Probe Tip Software
Clamp Meters and
Electrical Testers

The ergonomic clamp meters feature wide opening jaws for safe, fast
non-contact current measurement. The Fluke leakage clamp meter is
ideal for non-invasive checks of insulation resistance.
The range of electrical testers includes two-pole testers for taking
quick measurements in tight spaces, phase rotation indicators to
take the guess work out of checking phase/motor rotation, a
multipurpose cable locator and handy voltage alerts.
330 Series/902 Clamp Meters

Expanded capabilities for current


measurement
The Fluke 330 Series Clamp Meters offer The Fluke 902 adds temperature and
t the way capacitance measurement capabilities to
t the line, ideal for heating, ventilation and
perfectly in your hand and into tight air conditioning system inspections.
places. Meter controls are positioned so
that current measurements can be down
with one hand. A large backlit display (on
most models) is easy to see and a handy
Display Hold keeps measurements on the
display. Measuring starting current for
motors, lighting, etc. is easy with the in-
Fluke 336 Fluke 335 rush current function (on most models).
Features
F u n c ti o n s 333 334 335 336 337 902
True-RMS
Display backlight
Auto shut-off
Display Hold
Motor start-up current
Low battery indication
Large jaw
Min/Max
Current AC/DC *
Temperature

Fluke 334 Fluke 333


* DC A: 0-200 µA direct measurement

Fluke 337

Specifi cations
Functions Range 333 334 335 336 337 902
Current AC 0-400.0A 2% ± 5 counts
0- 600. 0A 2% ± 5 c ou n t s 2% ± 5 c ou n t s 2% ± 5 c ou n t s 1% ± 5 c ou n t s
0-999.9A 2% ± 5 counts
C r e s t Fa c t o r 0- 600. 0A 2. 4 @ 500A 3 @ 500A 2. 4 @ 500A
2. 0 @ 600A 2. 5 @ 600A 2. 0 @ 600A
0-999.9A 3 @ 500A
2.5 @ 600A
1.42@ 1000A
Current DC 0-200 µA 1% ± 5 counts
0- 600. 0A 2% ± 5 c ou n t s
Fluke 902
0-999.9A 2% ± 5 counts
In-rush Integration
100mS 100mS 100mS 100mS
True RMS Current time
Voltage AC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts
Voltage DC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts
Resistance 0-600.0Ω 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts

Included Accessories 0- 6000Ω 1. 5% ± 5 c ou n t s 1. 5% ± 5 c ou n t s 1. 5% ± 5 c ou n t s 1. 5% ± 5 c ou n t s


0-9999Ω 1.5% ± 5 counts
C33 Soft case, TL75 test leads, 80BK Integrated
C on ti n u i ty ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω ≤ 30Ω
DMM temperature probe (902),
Frequency 5-400Hz 0.5% ± 5 counts
2 AA alkaline batteries, instruction card and Temperature -10° to 400°C 1% ± 0.8°C
safety information sheet. Capacitance 1µF to 1000µF 1.9% ± 2 counts

Ordering Information Battery Life: Alkaline, 150 hours Jaw Opening: 30 mm (333, 334, 335 and 902)
Fluke 333 Clamp Meter Size (HxWxD): 42 mm (336, 337)
Fluke 334 Clamp Meter 238 mm x 79 mm x 41mm (333, 334, Weight: 0.312 kg
Fluke 335 True-RMS Clamp Meter 335 and 902) Three Year Warranty
Fluke 336 True-RMS Clamp Meter 251 mm x 79 mm x 41 mm (336 and 337)
Fluke 337 True-RMS Clamp Meter
Fluke 902 True-RMS Clamp Meter Recommended Accessories
(HVAC)

H3 TL223 L215
320 Series Clamp Meters

Big features, small package


The Fluke 321 and 322 are designed Model 322 also offers DC voltage
to verify the presence of load current, measurements and has a higher
ac voltage and continuity of circuits, resolution for loads below 40 A.
switches, fuses and contacts. These small
and rugged clamp meters are ideally
suited for current measurements up to
400 A in tight cable compartments.

Features
Functions 321 322
Compact design
Auto shut-off
Display Hold
Low battery indication
Current AC
Volts DC

Fluke 322

Specifi cations
321 322 321 322
Fluke 321 Functions Range Resolution Range Resolution Best Accuracy
Current AC 400.0A 0.1A 40.00A 0.01A 1.8% ± 5 counts 1.8% ± 5 counts
400.0A 0.1A (50 - 60Hz) (50 -60Hz)
3.0% ± 5 counts 3.0% ± 5 counts
(60Hz - 400Hz) (60Hz - 400Hz)
Voltage AC 0-400.0V 0.1V 0-400.0V 0.1V 1.2% ± 5 counts 1.2% ± 5 counts
400-600V 1V 400-600V 1V (50-400Hz) (50-400Hz)
V o l t a ge D C 0- 400. 0V 0.1V 1% ± 5 counts
400-600V 1V
Resistance 0-400.0Ω 0.1Ω 0-400.0Ω 0.1Ω 1% ± 5 counts 1% ± 5 counts
C on ti n u i ty ≤ 30Ω ≤ 30Ω

Battery Life: 100 hours typical Weight: 0.23 kg


(2 AAA carbon zinc) Two Year Warranty
Included Accessories Size (HxWxD): 190 mm x 63 mm x 35 mm
C23 Soft carrying case, TL75 test leads, Jaw Opening: 25 mm
(2) AA alkaline batteries, coated instruction
card, safety information sheet.
Combo Kit
Ordering Information
Fluke 321 Clamp Meter Fluke 62/322/1AC Kit Fluke 117/322 Kit
Fluke 322 Clamp Meter • Fluke 62 Infrared See page 4
Fluke 117/322 Kit Electricians Combo Kit Thermometer
Fluke 62/322/1AC IR Thermometer, Clamp • Fluke 322 Clamp Meter
Meter and Voltage • Fluke 1AC II Volt Alert
Detector Kit
Recommended Accessories

H3 TL223 L215
350 Series AC/DC Clamp Meters

True-RMS, 2000 A Clamp Meters


for industrial and utility applications
dently take reliable readings with Accurate peak measurements can be
the true-rms, Fluke 353/355 Clamp taken using the in-rush current mode -
Meters; the tools of choice for high ideal for motors and inductive loads. The
current measurement up to 2000 A. The 355 also measures voltage and resistance,
extra-wide jaw easily clamps around making this the most versatile tool
large conductors, typically found in high for utilities, electrical contractors and
current applications. The rugged design industrial service technicians.
and CAT IV 600 V,
CAT III 1000 V ratings add an extra
element of protection when taking
high-powered measurements.

F e a tu r e s
353 355
True-RMS measurements
Display backlight
Motor start-up current
Min/Max/Average
Voltage AC/DC
Fluke 353 Resistance measurement
Continuity measurement with beeper

Specifi cations
(Check the Fluke web for detailed specifications)

Fluke 355 F u n c ti o n s R a n ge 353 355


Current AC/DC 0-40.00 A 1.5% ± 15 counts 1.5% ± 15 counts
0-400.0 A
1.5% ± 5 counts 1.5% ± 5 counts
0-2000 A; 1400 AC rms
C r e s t Fa c t o r 2. 4 2. 4
V o l t a ge A C / D C 0- 4. 000 V 1% ± 10 c ou n t s
0-40.00 V
0-400.0 V
1% ± 5 counts
0-600 V AC rms
0-1000 V DC
Resistance 0-400.0 Ω
0-4.000 kΩ
0-40.00 kΩ 1.5% ± 5 counts
0-400.0 kΩ
Continuity beeper Appr. ≤ 30 Ω
Fr eq u en cy 5. 0H z t o 100. 0H z 0. 2% ± 2 c ou n t s
True RMS 100. 1H z t o 999H z 0. 5% ± 5 c ou n t s

Included Accessories
Fluke 353: C43 Soft Meter Case, 6 AA batteries, Power Supply: 6 x 1.5V AA NEDA 15A S ize (HxWxD): 300 mm x 98 mm x 52 mm
users manual or IEC LR6 Jaw opening: 58 mm
Fluke 355: C43 Soft Meter Case, 6 AA batteries, Battery Life: 100 hours (with typical Weight: 0.814 kg
TL224 SureGrip ® Silicone Test Lead Set, TP2 usage, backlight off) Two year warranty
Slim Reach Test Probe Set (2 mm), AC285
SureGrip ® Alligator Clip Set, users manual

Ordering information
Fluke 353 AC/DC Clamp Meter
Fluke 355 AC/DC Clamp Meter Recommended Accessories

TL223 (Fluke 355) L215 (Fluke 355)


360 Leakage Clamp Meter

Leakage current measurements with a tough,


pocket sized clamp meter
The Fluke 360 is ideal for non-invasive Features
checks of insulation resistance. • Measurement of leakage protectives
The unique jaw design eliminates the conductor and touch current with a
uence of adjacent current conductors. resolution of 1µA
The ergonomic design of the Fluke 360 • Advanced shielding to ensure accurate
ensures easy measuring. The measuring results when measuring near other
ts into tight spaces and the conductors
wide display angle clearly shows the • Automatic ranging within the manually
measurement result. The data hold selected mA or A range
button keeps the measured value on the • Easily viewed measurements on digital
display after removing the clamp for the and bargraph display and HOLD when
measured conductor. measuring in hard to see locations
• Broad range of measurements currents
The light Fluke 360 offers the widest up to 60 A for all installation needs
range of current measurement for • Easy carrying, pocket sized clamp with
maintenance professionals and wide 40 mm jaw size
contractors. • Display-Hold for convenience in use
• Auto power off with audible warning
buzzer
• Conformance to IEC61010 and EMC
standard
• Meets all the applications and
performance classes in safety standard
VDE0404-4 and the new VDE0702

Fluke 360

Specifi cations
(Check the Fluke web for detailed specifications)

Functions Range Resolution Accuracy


3mA 0.001A
Current AC 1% ± 5 counts
30mA 0.01mA
30A 0.01A 1% ± 5 counts (0~50A)
60A 0.1A 5% ± 5 counts (50~60A)
Frequency 50 and 60Hz

Battery type: 3 Volt Lithium, 90 hours typical


Size (HxWxD): 176 mm x 70mm x 25 mm
Weight: 0.2kg
One Year warranty

Included accessories
Soft carrying pouch and users manual display: 1.7mA

Ordering information leakage


Fluke 360 Leakage Clamp Meter current 0.5mA

ground leakage current


1.2mA (e.g. via
motor shaft)
T100 Series
Voltage and Continuity Testers

The fast and easy solution to voltage,


continuity and phase rotation testing
The fast and easy solution to voltage, Moreover they have a special electrical
continuity and resistance measurements. torch function for working in low light
Ideal for site conditions, the 3 models level environments and have an ingress
of the T100 Series 2-pole testers have a protection rating of IP65. The T100 Series
rugged construction and ergonomically are compliant with EN 61010-1 and
formed housing for perfect handling. EN61243-3 requirements.
All models offer a patented three-phase
rotation detection system providing
quick phase rotation indication.

Fluke T120

Features
T100 T120 T140
Display LCD LCD
L e d B a r gr a p h 1 2 L E D ’s 1 2 L E D ’s 1 2 L E D ’s
Backlight
Resistance measurement
Switchable load
Voltage test
Fluke T140
Optical and acoustical continuity test
Rotary field indication
Single pole test for phase detection
Indication of polarity
Fluke T100 Electrical torch function
Probe tip protection
The voltage display also functions when using
discharged - or o batteries

Specifi cations
T100 T120 T140
V o l t a ge A C / D C 12 - 690 V 12 - 690 V 12 - 690 V
C on ti n u i ty 0 - 400 k Ω 0 - 400 k Ω 0 - 400 k Ω
Fr eq u en cy 0 - 400 H z 0 - 400 H z 0 - 400 H z
Ph a s e r ot a t i on 100 t o 690 V 100 t o 690 V 100 t o 690 V
R es i s ta n ce m ea s u r em en t - - U p t o 1999 Ω
Included Accessories R es p on s e ti m e < 0. 1 s < 0. 1 s < 0. 1 s
Two 1.5V batteries and instruction sheet

Ordering Information
Fluke T100 Voltage/Continuity Tester
Size (HxWxD): 240 mm x 56 mm x 24 mm
Fluke T120 Voltage/Continuity Tester Case: IP65 (water-jet and dust tight protection)
Fluke T140 Voltage/Continuity Tester Weight: 180 g
Two year warranty
UK versions are compliant with GS38

Recommended Accessories

C33 (T100 Series)


T5 Electrical Testers

The fast and easy solution to basic


electrical testing
The Fluke T5 testers let you check
voltage, continuity and current with
one compact tool. Select volts, ohms or
current and the instrument does the rest.
Model T5-600 measures 600 volts
AC/DC, model T5-1000 is designed for
1000 volts. OpenJaw™ current technology
lets you check current up to 100 A,
without breaking the circuit. The optional
H5 holster keeps the test probes and
leads ready to test and lets you clip the
T5 onto your belt.

Features and Specifi cations


T 5- 600 T 5- 1000
D i s p l a y C ou n t 1000 1000
Fluke T5-1000 Fluke T5-600 Automatic Selection
Continuity and Bleeper
Sleep Mode
A C V o l t a ge 600 V 1000 V
D C V o l t a ge 600 V 1000 V
A C C u r r en t 100 A 100 A
R es i s ta n ce 1000 Ω 1000 Ω
S a f e t y r a n ge 600V C AT I I I 1000 V C AT I I I / 600 V C AT I V

Battery life: 400 hours Weight: 0.38 kg


Size (HxWxD): Two year warranty
203 mm x 51 mm x 30.5 mm

Fluke T5-H5-1AC Kit Fluke T5-600/62/1AC Kit

The ideal kit for busy electrical This kit is designed to help electricians
ts and HVAC technicians solve problems
of a voltage and current meter and non- rst for overheated electrical
Fluke T5-H5-1AC Kit
contact voltage detector all in one kit. A devices using an IR thermometer; then
holster for the T5 is also included. nd out more
about the problem.
Kit includes:
- Fluke T5-1000 Kit includes:
- H5 holster • Fluke T5-600
Fluke T5-600/62/1ACII Kit - Free Fluke 1AC-II • Fluke 62
• Fluke 1AC II
• C115
Included Accessories
TP4 4 mm detachable probes (detachable GS38
probes for the UK) and instruction sheet

Ordering Information
Fluke T5-600 Electrical Tester
Fluke T5-1000 Electrical Tester
Fluke T5-H5-1AC Kit Electrical Tester with
holster and IAC
Fluke T5-600/62/1AC Electrical Tester,
IR Thermometer,
Voltage Detector Kit
Recommended Accessories

H5 ACC-T5-Kit AC285
1AC II Volt Alert
LVD1/LVD2 Volt Lights
SM100/200/300 SocketMaster-testers

Fluke 1AC II VoltAlert™


The Fluke VoltAlert AC voltage detector is Operating range: 200 – 1000 V AC
very easy to use – just touch the tip to a Batteries: Two AAA Alkaline
terminal strip, outlet or cord. When the tip Size (H): 148 mm
glows red and the unit beeps, you know Two Year Warranty
there is voltage on the line.
• It continually tests its battery and its Fluke 1AC II VoltAlert™ 5-pack
circuit integrity with a periodic double • Buy 4 get 1 FREE
Fluke 1AC II ash visual indication.
• Highest safety rating: CAT IV 1000 V
• Detects voltage without metallic contact

LVD1 Volt Light


Dual sensitivity voltage detector
• Detects voltage from 40 V to 300 V AC
• Blue light means you’re close
• Red light means you’re at the source
• Comes with a versatile clip to secure light to
pocket, hat or even panel door
LVD1

LVD2 Volt Light


Combines bright light and voltage detection in one pen style design
• Dual sensitivity
• Detects voltage from 90 V to 600 V AC
• Blue light means you’re close
• Red light means you’re at the source
LVD2
• Rated to CAT IV 600 V

SM100/200/300 SocketMaster Testers


The fast way to check if your sockets are safe.

Ordering Information
Fluke 1AC II VoltAlert
Fluke 1AC II 5PK VoltAlert (5-pack)
LVD1 Volt Light
LVD2 Volt Light
SM100 SM200 SM300
SM100 SocketMaster Tester
SM200 SocketMaster Tester
SM300 SocketMaster Tester
Only available with UK plug
Features
SM100 SM200 SM300
Clear indication of wiring status
Audible notification of wiring status
Unique soft-touch RCD test checks 30 mA RCD´s for trip
within 300 ms
Earth Volts Touchpad detects raised earth voltages >50 V,
indicating potentially dangerous situations
9040/9062
Phase Rotation Indicators

Take the guess work out of phase/motor


rotation measurements
Fluke 9040 Fluke 9062
The Fluke 9040 is effective for measuring The unique Fluke 9062 provides rotary
phase rotation in all areas where eld and motor rotation indication with
three-phase supplies are used to feed ts of contact-less detection.
motors, drives and electrical systems. Purpose made for commercial and
eld indicator industrial environments, the Fluke 9062
and can provide clear indication of the provides rapid indication of 3 phase
3 phase via an LCD display and the rotation using test leads supplied or can
phase rotation direction to determine be used to determine motor rotation on
correct connections. It allows rapid synchronous and asynchronous 3 phase
determination of phase sequence motors. The contact-less detection is
and has a voltage (up to 700 V) and ideal for use on motors where the shaft is
frequency range suitable for commercial not visible.
and industrial applications. Test probes Test probes supplied with the instrument
supplied with the instrument have a have a variable clamping range for safe
variable clamping range for safe contact, contact, especially in industrial sockets.
especially in industrial sockets.

Fluke 9040
Features
9040 9062
3 phase indication Via LCD Via LED
Indication of phase rotation
Indication of motor rotation direction
Contact free determination of the rotation direction of running motors
Clear LCD display
No battery required

Fluke 9062

9040:

Specifi cations
9040 9062
V o l t a ge r a n ge 40 - 700 V U p t o 400 V
Ph a s e d i s p l a y - 120 - 400 V A C
F r e q u e n c y r a n ge 15 - 400 H z 2- 400 H z
9062:
Oper a ti n g ti m e C on ti n u ou s C on ti n u ou s

Size (HxWxD) Fluke 9040: Power supply 9040: from unit under test
124 mm x 61 mm x 27 mm Power supply 9062: 1 x 9V
Size (HxWxD) Fluke 9062: Weight 9040: 0.20 kg
124 mm x 61 mm x 27 mm Weight 9062: 0.15 kg
Two Year Warranty

Included Accessories Fluke 9062 Applications


Fluke 9040: Alligator clips - black (3)
Flexible test probes - black (3)
Fluke 9062: Alligator clips - black (3)
Flexible test probes - black (3)
Test leads - black (3)

Ordering Information Determine the presence of Determine the rotation of Check the correct rotation of
Fluke 9040 Phase Rotation Indicator phase sequence of multiphase running motors simply by motors prior to connection.
Fluke 9062 Motor and Phase Rotation electrical supplies. placing the instrument on
Indicator the motor casing.

Recommended Accessories

TLK290 TLK291 C25


2042 Cable Locator

The multipurpose solution to cable location


The Fluke 2042 is a professional general • Receiver with a backlight LCD-display
purpose cable locator. It is ideal for for level of receiving signal, code
tracing cables in walls and underground, of receiving signal and live voltage
nal circuits indication
and locating interruptions and short- • Automatic or manual adjustment of
oor receiving signal sensitivity
heating systems. • Switchable acoustic receiving signal
It can also be used for tracing metallic • Auto-Power-Off
water and heating pipes. The unit is • Additional torch lamp function for
supplied as a complete kit comprising of working in dark environments
a transmitter and receiver in a purpose- • Additional transmitters are available
made carry case. The receiver also for extension or to distinguish between
incorporates a torch function for working several signals.
in dimly lit locations.

• For all applications (live or dead cables)


without additional instruments
• Set includes a transmitter and a
Transmitter receiver
• Proven digitally coded sender signal
cation
Receiver
• Transmitter with LCD-display for
transmitting level, transmitting code
and external voltage
Fluke 2042 Specifi cations
Transmitter Receiver
V o l t a ge M e a s u r e m e n t R a n ge 12V, 50V, 120V, 230V, 400V
F r e q u e n c y R a n ge 0. . 60 H z
O u t p u t s i gn a l 125 k H z
V o l t a ge U p t o 4 0 0 V A C /D C
T r a c i n g d e p t h c a bl e l o c a t i o n 0 . . . 2 . 5 m w a l l /u n d e r gr o u n d
cables
M a i n v o l t a ge d e t e c t i o n 0. . . 0. 4m

Batteries Transmitter: 6 pc Batteries 1.5V


Batteries Receiver: 1 pc Battery 9V
Size (HxWxD) Transmitter:
190 mm x 85 mm x 50 mm
Size (HxWxD) Receiver:
250 mm x 65 mm x 45mm
Weight Locator: 0.45 kg
Weight Receiver: 0.36 kg
Two Year Warranty

Fluke 2042 applications

Included Accessories
TL27 Heavy Duty Test Lead Set (2)
TP74 Lantern Tip Test Probe Set
AC285 Alligator Clip Set
Soft carrying case
Hard case
Location of fuses/breakers Tracing of underground Precise location of cable
and assignment to circuits cables (max. depth 2.5 m) interruptions with additional
Ordering Information transmitter
Fluke 2042 Cable Locator
(transmitter + receiver)
Fluke 2042T Cable Locator Transmitter

Recommended Accessories

Fluke 2042T
Insulation Testers and
Earth Ground Testers

With a 5000 V MegOhmMeter for industrial-strength insulation testing


and a range of compact hand-held instruments, we offer a solution
for every troubleshooting and preventive maintenance application.
Two of the digital hand-held insulation testers also include full-featured
multimeters.
The Fluke Earth Ground Testers can perform all four types of earth
ground measurement, including stakeless testing with earth ground
loop resistances using only clamps.
Insulation Tester
Selection Guide

1577 1587 1587T 1503 1507 1550B


InstallationTest Functionality
T e s t v o l t a ge s 500V, 1000V 50V, 100V, 250V, 500V, 50V, 100V 500V, 1000V 50V, 100V, 250V, 500V, 250V, 500V, 1000V,
1000V 1000V 2500V, 5000V
I n s u l a t i o n R e s i s t a n c e T e s t R a n ge 0. 1M Ω - 600M Ω 0. 01 M Ω - 2G Ω 0. 01M Ω - 100M Ω 0. 1M Ω - 2G Ω 0. 01M Ω - 10G Ω 200K Ω - 1T Ω
Polarization Index/Dielectric Absorption Ratio
Auto Discharge
Time Ramp test (Breakdown)
Pass/Fail Comparison
Estimated Number of 1000 1000 1000 1000 1000
Insulation resistance Tests
Voltage > 30V Warning
Memory (99 locations)
Remote Test Probe
Lo Ohms
D i s play D i gi t a l L C D D i gi t a l L C D D i gi t a l L C D D i gi t a l L C D D i gi t a l L C D D i gi t a l L C D / A n a l o g
Bar Graph
Continuity (200mA) (200mA)

Multimeter Functionality
AC/DC Volts
Current
Resistance
Temperature (contact)
Lo-Pass Filter
Capacitance
Diode Test
Frequency
MIN/MAX

Other
Hold/Lock
Backlight
(Fluke View ® Forms
Software
Basic)
W a r r a n t y (i n y e a r s ) 3 3 3 1 1 2
4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or 4 AA (NEDA 15A or
Battery Rechargeable
IEC LR6) IEC LR6) IEC LR6) IEC LR6) IEC LR6)

Buy a Fluke 1587 Combo Kit and save


Fluke 1587/ET Advanced Electrical Fluke 1587/MDT Advanced Motor
Troubleshooting Kit & Drive Troubleshooting Kit

This kit contains: This kit contains:


• Fluke 1587 Insulation Multimeter • Fluke 1587 Insulation Multimeter
• Fluke 62 Mini Infrared Thermometer • Fluke 9040 Phase Rotation Indicator
• i400 Current Clamp • i400 Current Clamp
Fluke 1587/ET
Perform insulation tests with the Fluke Perform insulation tests with the Fluke
1587 plus a wide-range of DMM tasks with 1587 plus a wide-range of DMM tasks with
dence and ease. Use the i400 with your dence and ease. Use the i400 with your
Fluke 1587 to accurately measure AC current Fluke 1587 to accurately measure AC current
without breaking the circuit. Check for hot without breaking the circuit. Check the phase-
spots and measure temperature with the rotation of three-phase motors easily and
Fluke 62 Mini non-contact thermometer. safely with the Fluke 9040.

Fluke 1587/MDT
1503/1507 Insulation Testers

Truly portable insulation resistance testers


When you need a low cost solution to The multiple test voltages on both
general purpose insulation testing look models make them ideal for many
no further than the new Fluke insulation troubleshooting, commissioning and
tester range. The Fluke 1507 and 1503 preventive maintenance applications.
Insulation Testers are compact, rugged, Additional features like the remote
reliable and easy to use. probe save both time and money when
performing tests.

Features
1503 1507
User selectable test voltages for many applications
Additional test voltages 50V, 100V, 250V
Special remote control probe for easy and safe measurements
Auto-discharge of capacitive voltage for added user protection
Fluke 1503 Live circuit detection prevents insulation test if voltage > 30 V
is detected for added user protection
Save both time and money with Automatic calculation of
Polarization Index and Dielectric Absorption Ratio
Auto Power off to save batteries
Large display with backlight
Continuity function (200 mA)
Compare function (pass/fail) for fast repetitive tests

Fluke 1507

Specifi cations
I n s u l a ti o n s p e c i f i c a ti o n s 1503 1507
I n s u l a t i o n t e s t r a n ge 0. 1 M Ω t o 2 G Ω 0. 01 M Ω t o 10 G Ω
T e s t v o l t a ge s 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V
T e s t v o l t a ge a c c u r a c y + 20 %, - 0 % + 20 %, - 0 %
I n s u l a ti on tes t c u r r en t 1m A n om i n a l 1m A n om i n a l
A C / D C V o l t a ge m e a s u r e m e n t 6 0 0 V (0 . 1 V r e s o l u t i o n ) 6 0 0 V (0 . 1 V r e s o l u t i o n )
R e s i s t a n c e m e a s u r e m e n t r a n ge 0. 01 Ω t o 20 k Ω 0. 01 Ω t o 20 k Ω
A u t o d i s c h a r ge D i s c h a r ge t i m e < 0 . 5 s e c o n d Discharge time < 0.5 second
for C = 1 µF or less for C = 1 µF or less
M a x i m u m c a p a c i ti v e l oa d U p to 1 µ F U p to 1 µ F
O p e n c i r c u i t t e s t v o l t a ge >4V ,<8V >4V ,<8V
S h or t c i r c u i t c u r r en t > 200 m A > 200 m A

Battery life: Insulation Test: > 1000 tests Weight: 0.55 kg


Size (HxWxD): One Year Warranty
203 mm x 100 mm x 50 mm

Fluke 1503/1507 Applications


Included Accessories
TP165x Remote Test Probe
TL224 SureGrip Silicone Test Lead Set
TP74 Lantern Tip Test Probe Set
Alligator clips

Ordering Information
Fluke 1503 Insulation Tester Insulation test at a Wiring test in a small
Fluke 1507 Insulation Tester distribution panel distribution box –
all in one spot

Recommended Accessories

C101 PAK TLK 225 AC285 L210


1577/1587
Insulation Multimeters

Two powerful tools in one


The Fluke 1587 and 1577 Insulation Whether you work on motors, generators,
Multimeters combine a digital insulation cables, or switch-gear, the
tester with a full-featured True RMS Fluke 1587/1577 Insulation Multimeters
digital multimeter in a single compact, are ideally suited to help you with your
handheld unit, which provides maximum tasks.
versatility for both troubleshooting and
preventive maintenance. The Fluke 1587T is specially designed for
the telecom environment.

Features
M u l ti m e te r Fe a tu r e s 1577 1587 1587T
True RMS Voltage and Current for accurate measurements
D i gi t a l d i s p l a y c o u n t s 6000 6000 6000
Autorange and manual range for easy testing.
Selectable filter for accurate voltage and frequency measurements on motor
drives
Min Max Recording, Diode test, temperature, capacitance & frequency
measurement for maximum flexibility.
Fluke 1577
Insulation features
User selectable test voltages for many applications
Additional test voltages 50V, 100V, 250V
Special remote control probe for easy and safe measurements
Auto-discharge of capacitive voltage for added user protection
Live circuit detection prevents insulation test if voltage > 30V is detected for
added user protection

General features
Auto Power off to save batteries
Large display with backlight
Fluke 1587 Input Alert to warn for incorrect connections
Fluke 1587T
Continuity

Insulation Specifi cations


F u n c ti o n s 1577 1587 1587T
Measurement range 0.1MΩ to 600MΩ 0.01MΩ to 2GΩ 0.01MΩ to 100MΩ
T e s t v o l t a ge s 500V, 1000V 50V, 100V, 250V, 500V, 50V, 100V
1000V
Test voltage accuracy + 20%, -0% + 20%, -0% + 20%, -0 %
Insulation test current 1mA nominal 1 mA nominal 1 mA nominal
A u t o d i s c h a r ge D i s c h a r ge t i m e < 0 . 5 s Discharge time <0.5s Discharge time <0.5s
for C = 1 µF or less for C = 1 µF or less for C = 1 µF or less
Maximum capacitive load Up to 1 µF load Up to 1 µF load Up to 1 µF load

Multimeter Specifi cations


Functions Maximum Max. resolution 1577 1587/1587T
Voltage DC 1000V 1 mV ± (0.2% + 2) ± (0.09% + 2)
Voltage AC 1000V 0.1mV ± (2% + 3) ± (2% + 3)
Current DC 400mA 0.01mA ± (1.0% + 2) ± (0.2% + 2)
Current AC 400mA 0.01mA ± (2% + 2) ± (1.5% + 2)
Resistance 50.0MΩ 0.1Ω ± (1.2% + 2) ± (0.9% + 2)
C a pa ci ta n ce 9999µ F 1 nF - ± (1 . 2 % + 2 )
Fr eq u en cy 99. 99k H z 0. 01 H z - ± (0 . 1 % + 1 )
T em per a tu r e - 4 0 ° C t o +5 3 7 ° C 0. 1° C - ± (1 % + 1 0 )
Included Accessories
C101 Rugged, utility hard case Battery life: Meter: 1000 hrs, Weight: 0.55 kg
TL224 SureGrip Silicone Test Lead Set Insulation Test: >1000 tests Three Year Warranty
AC285 SureGrip Alligator Clip Set Size (HxWxD):
203 mm x 100 mm x 50 mm
80BK Integrated DMM Temperature Probe
(Type K) Recommended Accessories
TP165X Remote Test Probe

Ordering Information
Fluke 1577 Insulation Multimeter
Fluke 1587 Insulation Multimeter
Fluke 1587T Insulation Multimeter C25 i400 TPAK L215 TL238

(for Telecom)
1550B MegOhmMeter

Digital insulation testing up to 5000 Volts


The Fluke 1550B is a digital insulation • Guard system eliminates the effect
tester capable of testing switchgear, of surface leakage current on high-
motors, generators and cables at up to resistance measurements
5000 V DC. It can be used for a wide range • Large digital/analog LCD shows detailed
of tests: from simple spot checks to timed measurement data
tests and breakdown tests. Measurement • Cable or insulation capacitance
storage and PC interface software make it • Leakage current
ideal for preventive maintenance. • Ramp function (0-5000 V DC) for
breakdown testing
• Test voltages of 250 V, 500 V, 1000 V, • Timer 1 to 99 minutes
2500 V, 5000 V • Polarization index and dielectric
• Capable of testing in 50 V increments absorption calculated automatically
between 250 V and 1000 V, and 100 V • 99 memory locations store all
increments between 1000 V and 5000 V measurements parameters
• Measures 0 to 1 Tera-Ohm • Includes Quicklink 1550B Software and
• Warning voltage function alerts the Optical Interface cable
user that line voltage is present and
gives the voltage reading up to 600 V
AC or DC

Fluke 1550B

Specifi cations
T e s t V o l t a g e (D C ) R a n ge A c c u r a c y ( +/ - r e a d i n g )
250V 200k Ω t o 5G Ω 5%
5GΩ to 50GΩ 20%
500V 200k Ω t o 10G Ω 5%
10GΩ to 100GΩ 20%
1000V 200k Ω t o 20G Ω 5%
20GΩ to 200GΩ 20%
2500V 200k Ω t o 50G Ω 5%
50GΩ to 500GΩ 20%
5000V 200k Ω t o 100G Ω 5%
100GΩ to 1TΩ 20%
S h or t c i r c u i t c u r r en t gr e a t e r t h a n 1 m A a n d l e s s t h a n
2mA
B a r gr a p h r a n ge 0 t o 1T Ω
Insulation test voltage accuracy 0% to + 10% at 1mA load current
Induced AC mains current rejection 2 mA maximum
Charging rate for capacitive load 5 seconds per µF

L e a k a ge c u r r e n t 1n A t o 2m A ± (5 % + 2 n A )
C a pa ci ta n ce m ea s u r em en ts 0. 01µ F t o 15. 00µ F ± (1 5 % r d g + 0 . 0 3 µ F )
L i v e c i r c u i t i n d i c a tor 3 0 V t o 6 0 0 V A C /D C , 5 0 /6 0 H z ± (5 % + 2 V )
Timer increments; indicated to within 1 second 1 to 99 minutes; settable in
1 minute
Ram p 0% t o 100% of s el ec t ed t es t
voltage, or until breakdown.

Included Accessories
Test leads, 5000 V-rated probes, Alligator clips,
Interface cable
Flukeview Forms Basic, soft carrying case with Operating Temperature: -20°C to 50°C Batteries: 12 volt, lead-acid, rechargeable
water-proof bottom, instruction manual Storage Temperature: -20°C to 65°C Size (HxWxD): 170 mm x 242 mm x 330 mm
Relative humidity: 80% at 31°C, Weight: 4 kg (with battery)
50% at 50°C Two Year Warranty
Ordering Information Dust/water resistance: IP40
Fluke 1550B MegOhmMeter Operating Altitude: 0 to 2,000 mtrs.

FVF-SC2
1620 Series
Earth Ground Testers GEO

Advanced technology for all your earth


ground testing applications
The new Fluke 1620 Series Earth Ground Earth ground resistance and soil
Testers not only measure ground resistivity should be measured
resistance using the classic ‘fall of when:
potential test’ but also enable time • Designing earth ground systems
saving testing using the ‘selective’ and • Installing new ground system and
‘stakeless’ methods. ‘Selective’ testing electrical equipment
does not require the electrode under • Periodically testing ground and
test to be disconnected during the lightning protection systems
measurement, thus increasing safety. • Installing large electrical equipment
The simple ‘stakeless’ method quickly such as transformers, switchgears,
Fluke 1623 checks ground connections using two machines, etc.
current transformers (probes) clamped
around the ground conductor under test.
Offering ‘one-button’ simplicity, the 1623
is an all-in-one earth ground tester, while
the 1625 has extra versatility for more
demanding applications.

Features
1623 1625
One-button measurement concept
3- and 4-pole earth ground measurement
4-Pole soil resistivity testing
2-Pole resistance measurement AC
Fluke 1625
2-and 4-pole resistance measurement DC
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)
Measuring frequency 128 Hz
Earth impedance measurement at 55 Hz
Automatic frequency control (AFC) (94 – 128 Hz)
Measuring voltage switchable 20/48V
Programmable limits, settings
Continuity with buzzer
D u s t /w a t e r r e s i s t a n c e I P56 I P56
Safety rating CAT II 300 V CAT II 300 V

Specifi cations
(Check the Fluke web for detailed specifications)

1623 1625
Fluke 1625 kit
R e s i s t a n c e r a n ge s 0 t o 20 k Ω 0 t o 300 k Ω
O p er a ti n g er r or ± 5% ± 5%
Included accessories T e s t v o l t a ge 48 V 20 / 48 V
Fluke 1623: Protective holster, 2 test leads, S h or t c i r c u i t c u r r en t > 50m A 250 m A
2 alligator clips, users manual
Fluke 1623 Kit: same as above plus stake/reel
Set 4 pole and selective/stakeless clamp set Battery type: 6 x AA alkaline cells
Fluke 1625: Protective holster, 2 test leads, Size (HxWxD): 110 mm x 180 mm x 240 mm
Weight – 1623 Geo: 1.1 kg (including batteries)
2 alligator clips, users manual
1625 Geo: 1.1 kg (including batteries)
Fluke 1625 Kit: same as above plus stake/reel Two Year Warranty
set 4 pole and selective/stakeless clamp set

Ordering information Recommended Accessories


Fluke 1623 Basic GEO Earth Ground
Tester
Fluke 1623 Kit Basic GEO Earth Ground EI-162BN
320mm Split core
Tester Kit transformer for selective
Fluke 1625 Advanced GEO Earth measurements on high
voltage pylons
Ground Tester
Fluke 1625 Kit Advanced GEO Earth
Ground Tester Kit EI-1623 EI-1625 ES-162P3 ES-162P4
Selective/stakeless clamp Selective/stakeless clamp Stake/reel set for 3 pole Stake/reel set for 4 pole
set for 1623 set for 1625 measurements measurements
1621 Earth Ground Tester

Handheld earth ground testing


for mobile use
The Fluke 1621 is an easy-to-use Features
rst line of • 3-pole Fall-of-Potential earth testing for
defense in detecting reliable ground basic measurements
connections, the unit features basic • 2-pole resistance measurements for
ground testing methods including 3-pole added versatility
Fall-of-Potential as well as 2-pole ground • Easily capture values with single-button
resistance. Its convenient size, rugged operation
holster, and large, clear LCD display make • Ensure accurate measurements with
eld earth tester, for most automatic ‘noise’ voltage detection
work environments. With a simple user • Hazardous voltage warning offers
interface and intuitive functionality, the increased user protection
Fluke 1621 is a handy tool for electrical • Clearly read and record data with a
contractors, utility test engineers, and large, backlit display
earth ground specialists. • Rugged holster and design for tough
work environments
• Portable size allows for easy
transportation
• Instantly be alerted to measurements
outside of your set limit, when you use
the adjustable limit setting
• Safety rating CAT II 600 V

Fluke 1621

Specifi cations
(Check the Fluke web for detailed specifications)

1621
R e s i s t a n c e r a n ge 0. 15 Ω t o 2 k Ω
B a s i c a c c u r a cy ± 6% of m ea s u r ed v a l u e + 5D
O p er a t i n g er r or a c c or d i n g E N 61557 ± 1 8 % o f m e a s u r e d v a l u e +5 D
T e s t v o l t a ge 23 t o 24 V A C
S h or t c i r c u i t c u r r en t > 50 m A A C

Battery type: 1 x 9 V alkaline (LR61)


Size (HxWxD): 216 mm x 113 mm x 54 mm
Weight: 0.850 kg
Two Year Warranty

Recommended Accessories
Included accessories
Two measuring leads with alligator clips -
2 m, protective holster, users manual, CD-ROM

Ordering information
Fluke 1621 Earth Ground Tester
GEO CABLE-REEL 25M GEO CABLE-REEL 50M GEO EARTH STAKE ES-162P3
Ground Earth Cable Reel Ground Earth Cable Reel Ground Earth Stake Stake/reel set for 3 pole
25 M Wire 50 M Wire measurements
1630 Earth Ground
Clamp Meter

Fast and easy earth ground loop testing


The Fluke 1630 earth ground clamp • Rapid evaluation of continuity without
es ground loop testing and disconnection and audible HI/LO alarm
enables non-intrusive leakage current • Display-HOLD function to freeze
measurement. The ground loop testing is measurements
also known as “stakeless” earth ground • Recording function for automatic
testing. To carry out the measurement storage of measured values, which can
there is no need for placing earth stakes be recalled later on the LCD display
and disconnecting the earth system • Automatic self calibration ensures
from the electrical installation. The Fluke correct measurement every time
1630 combines the two current clamps
needed to perform the stakeless ground The Fluke 1630 is ideally suited for the
loop test in one compact and easy to use following applications:
instrument. • Ground loop checks on any earthing
• Ground loop resistance testing without system
any disconnection or additional earth • Continuity tests on earth bonding
stakes circuits and connections
• Earth ground leakage current • Inspection of lightning protection
measurement for system systems
troubleshooting • Leakage current measurement for
• True RMS AC current measurement troubleshooting on earth ground
range up to 30 A systems

S p e c ifications
(Check the Fluke web for detailed specifications)

Range Max. resolution


R es i s ta n ce 0. 025 t o 1500 Ω 0. 002 Ω
Fluke 1630 C n t i n u i t y bu z z e r < a p p. 40 Ω
L e a k a ge c u r r e n t 0. 2 t o 1000 m A 0. 001 m A
Current 0.2 to 30 A 0.01 A

Weight: 0.64 kg
Conductor Size: 35 mm approx.
Size (HxWxD): 257 mm x 100 mm x 47 mm
Battery type: 9 V IEC 6 LR 61
Two Year Warranty

Ground resistance measurements principle


Ground resistance measurements principle

Rg R1 R2 R3 .....Rn

Equivalent circuit diagram

Included Accessories
Rugged carrying case with belt, Resistance test R1 R2 .....Rn
loop, 9 V battery, Operating instructions.

Ordering Information
Fluke 1630 Earth Ground Clamp Meter Rg

Rg
Digital Thermometers

For troubleshooting systems where temperature is a critical symptom,


our digital thermometers provide you with laboratory accuracy wherever
you need it. We offer a choice of non-contact, laser-guided infrared
thermometers for safely getting at hard-to-reach, electrically live or
particularly hot targets, and contact thermometers with a full range of
thermocouple probes.
Infrared Thermometer Flu k e 60 S er i es Flu k e 560 S er i es Flu k e 570 S er i es
Selection Guide Fluke 61 Fluke 62 Fluke 63 Fluke 66 Fluke 68 Fluke 561 Fluke 566 Fluke 568 Fluke 572 Fluke 574
Temperature range -18 to 275 ºC -30 to 500 ºC - 32 to 535 ºC - 32 to 600 ºC - 32 to 760 ºC - 40 to 550 ºC - 40 to 650 ºC - 40 to 800 ºC - 30 to 900 ºC - 30 to 900 ºC
A c c u r a cy 2% 1. 5% 1% 1% 1% 1% 1% 1% 0. 75% 0. 75%
Response time < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 250 mSec < 250 mSec
Optical resolution 8:1 10:1 12:1 30:1 50:1 12:1 30:1 50:1 60:1 (50:1 60:1 (50:1
with close with close
focus) focus)
Close focus model
available
Recommended distance Up to 2 m Up to 2 m Up to 2.5 m Up to 4.5 m Up to 7.5 m Up to 2.5 m Up to 4.5 m Up to 7.5 m 300 mm 300 mm
to spot (with close (with close
focus) up to focus) up to
10.5 m 10.5 m
Laser sighting single-point single-point single-poimt single-point single-point single-point single-point single-point 3-point 3-point
laser laser laser laser laser laser laser laser laser laser
Adjustable emissivity
MIN/MAX readings -/ -/
AVG readings
DIF readings
Backlit LCD
Bar graph display
Audible Hi/Lo alarm /-
Visible Hi/Lo alarm /-
Includes contact probe
Probe input (types) Type K Type K Type K Type K
RTD RTD
Thermocouple Thermocouple Thermocouple Thermocouple
Data logging (number of
12 p oi n t s 12 p oi n t s 20 p oi n t s 99 p oi n t s 100 p oi n t s
measurements)
PC interface USB R S 232
Compatible with
FlukeView Forms
software

See catalog page 52 52 52 52 52 54 53 53 51 51

Recommended Applications
Infrared Thermometer
Selection Guide

Contact thermometers Plant/facilities maintenance Heating/ventilation/air conditioning/ Manufacturing processes Safety and protection
For our complete range of contact Preventive and predictive maintenance refrigeration Molding temperature measurement Fire localization
thermometers, see page 55. Energy audits Leaky ductwork Printing, paper and converting Hazardous materials
Vehicle and fleet maintenance Thermostats Thermoforming plastics Faulty ballasts
programs Temperature balancing Electronics Search and rescue
Faulty electrical/circuit connections Steam distribution systems Paint curing/drying Smoldering embers
Petrochemical/hazardous locations Compressor lines Food Equipment maintenance
Motors, pumps and bearings Chemical and pharmaceutical
570 Series
Precision Infrared Thermometers

Measure temperature with ease and


precision
The Fluke 570 series are the most • Enhanced optics allows measurements
advanced IR non-contact thermometers, of smaller objects from farther away
and are ideal for predictive and • True Dimension™ three-dot laser
preventative maintenance applications. sighting system highlights the true
Offering a broad temperature range diameter of measurement spots at all
and a true dimension laser sighting distances
system for precise targeting resulting • Adjustable emissivity setting and 30
in more accurate measurements. When pre-set common material values for
requiring analysis and documentation more accurate measurements
use the 100-point data logging and • 100 data point memory for storage of
software for graphing and analysis. measurements (Fluke 574).
From close-up electrical connections, to
far-distance room balancing checks, the
Fluke 570 series can take IR temperature
measurements with ease and precision.

Fluke 574

Features
572 574
Temperature range -30 to 900ºC
Optical resolution Standard: 60:1
Close focus: 50:1
3 dot laser beam for accurate targeting
Adjustable emissivity
Bar graph display
Backlit LCD display
Use selectable ºC or ºF
Audible and visible Hi/Lo Alarm /- /
MIN/MAX
AVG/DIF readings
D a t a l o ggi n g (n u m be r o f m e a s u r e m e n t s ) 100
PC interface RS232

Specifi cations
572 574
Temperature range -30 to 900°C
Response time 250ms (95 % of reading)
Resolution 0.1°C of reading up to 900°C
Fluke 572
Repeatability ±0.5% of reading or ±1°C*
Accuracy: (assumes ambient operating temperature of 23 ºC to 25 ºC ) ±0.75% of reading, ±0.75°C *
T y p i c a l d i s t a n c e t o t a r ge t 10, 5 m
E m i s s iv i ty D i gi t a l l y a d j u s t a b l e f r o m 0 . 1 0 t o 1 . 0
by 0.01
Included Accessories *whichever is greater.
Fluke 572: Hard case, 2 batteries
Fluke 574: Hard case, 2 batteries, Thermocouple
K probe, 220V power supply, IRGraph software,
RS232 cable Battery Life: 10 hours typical
Weight: 0.480 kg
Size (HxWxD): 200 mm x 170 mm x 55 mm
Ordering Information Two years warranty
Fluke 572 Precision Infrared Thermometer
Fluke 574 Precision Infrared Thermometer
Fluke 572CF Precision Infrared Thermometer Recommended Accessories
with close focus option
Fluke 574CF Precision Infrared Thermometer
with close focus option

AN5 C570
Analog data cable See page 118
60 Series
Infrared Thermometers

Point, press and read temperature


The Fluke 60 Series non-contact The 60 Series IR thermometers
thermometers are the ideal professional feature:
diagnostic tools for quick and accurate • Laser guided sighting system for easy
temperature measurements. targeting with 1% accuracy
These handheld tools are ideal for • Up to 12 points datalogging with Min/
measuring surface temperatures of Max/Average functions
rotating, hard-to-reach, electricity live • Up to 50:1 optical resolution
or dangerously hot targets like electrical • Choice between models with fixed or
motors and – panels, and heating and adjustable emissivity
ventilation systems. • Backlit display for easy reading in the
Fluke 68 The laser sighting system guides dark
measurements to the right target and in • Temperatures up to 760°C
less than a second, the large temperature
display provides a readout of the surface
temperature.
Fluke 66
Features
61 62 63 66 68
For m f a c t or F l a t gr i p P i s t o l gr i p P i s t o l gr i p P i s t o l gr i p P i s t o l gr i p
Fluke 63 T e m p e r a t u r e r a n ge - 18 t o 275° C - 30 t o 500 ° C - 32 t o 535° C - 32 t o 600° C - 32 t o 760° C
O p ti c a l r es ol u ti on 8: 1 10: 1 12: 1 30: 1 50: 1
Fluke 62
Laser beam for accurate targeting
Backlit LCD display
Use selectable °C or °F
M i n /m a x /a v g/d i f r e a d i n gs M ax M ax
Datalogging
Hi/Lo Alarm
Adjustable emissivity

Specifications
61 62 63 66 68
R a n ge - 1 8 t o 2 7 5 ºC - 3 0 t o 2 7 5 ºC - 3 2 t o 5 3 5 ºC - 3 2 t o 6 0 0 ºC - 3 2 t o 7 6 0 ºC
Response time < 500ms < 500ms ≤ 0.5 second ≤ 0.5 second ≤ 0.5 second
(95 % of reading)
R es ol u ti on 0 . 2 ºC 0 . 2 ºC 0 . 2 ºC 0 . 1 ºC 0 . 1 ºC

Repeatability ± 2% ± 0.5% ± 0.5% ± 0.5% ± 0.5%


Fluke 61 (% of reading) or ± 2 ºC* or < ± 1 ºC* or ≤ ± 1 ºC* or ≤ ± 1 ºC* or ≤ ± 1 ºC*
Accuracy: For targets at: For targets at: For targets at: For targets at: For targets at:
(assumes ambient -18 to -1ºC: ± 3ºC 10 °C to 30 °C: ±1 °C -32 to -26°C: ± 3°C -32 to -26°C: ± 3°C -32 to -26°C: ± 3°C
operating temperature -1 to 275ºC: ± 2% of ± 1.5% of reading -26 to -18°C: ± 2.5°C -26 to -18°C: ± 2.5°C -26 to -18°C: ± 2.5°C
of 23ºC) reading or ± 2ºC or ± 1.5°C whichever -18 to 23°C: ± 2°C -18 to 23°C: ± 2°C -18 to 23°C: ± 2°C
is greater over 23°C -510°C: ± 1% For targets above For targets above
the balance of the range of reading or ± 1°C* 23 ºC: 23 ºC:

The Fluke FoodPro™ thermometer For targets


above 510°C:
± 1% of reading
or ± 1 ºC*
± 1% of reading
or ± 1 ºC*

series provide advanced ± 1.5% of reading

temperature measurement solutions Typical distance to Up to 1m Up to 1.5 m Up to 2 m 5m 8m


target
for the foodservice industry. Check Emissivity Fixed at 0.95 Pre-set to 0.95 Fixed at 0.95 Digitally adjustable Digitally adjustable
the Fluke web for more information. from 0.1 to 1.0 from 0.1 to 1.0
by 0.01 by 0.01

* whichever is greater

Battery Life: Weight:


Fluke 66 and 68: 20 hours with laser and backlight on 50% Fluke 63, 66 and 68: 0.320 kg
Included Accessories Fluke 63: 10 hours with laser and backlight on Fluke 62: 0.200 kg
Fluke 61: 9V Battery Fluke 62: 12 hours with laser and backlight on Fluke 61: 0.227 kg
Fluke 61: 12 hours with laser and backlight on
Fluke 62: 9V Battery, storage holster Fluke 62: 2 years warranty
Fluke 63, 66 and 68: Hard carrying case, Size (HxWxD): Other models: one year warranty
9V batteries Fluke 63, 66 and 68: 200 mm x 160 mm x 55 mm
Fluke 62: 152 mm x 101 mm x 38 mm
Fluke 61: 184 mm x 45 mm x 38 mm

Ordering information Kits Recommended Accessories


Fluke 61 Infrared Thermometer
Fluke 62 Mini Infrared Thermometer
Fluke 63 Infrared Thermometer
Fluke 66 Infrared Thermometer
Fluke 68 Infrared Thermometer
Fluke 62/322/1AC (see page 5) C23 80PR-60 H6
Fluke T5-600/62/1AC (see page 5)
Fluke 62/322 kit T5-600/62/1AC
566 and 568
Multipurpose Thermometers

The two-in-one infrared and contact thermo-


meter with an innovative graphical display
With a straight-forward, menu-driven • Easily access advanced features with
user interface and graphical display, the soft-key buttons and graphical
the Fluke 566 and 568 multipurpose display
thermometers make even complex • Measure smaller targets from farther
temperature measurements easy. Quickly away using the IR thermometer
navigate and adjust emissivity, start data • Adjustable emissivity and built-in table
logging, or turn on and off alarms, with of common materials for higher IR
just a few pushes of a button. For added accuracy
convenience, both rugged handheld • Quickly identify problems with the MIN,
thermometers combine contact and MAX, AVG, and DIF functions
non-contact temperature measurement ashing alarm alerts you
capability, providing a total temperature visually when measurements exceed
measurement solution for any service limits
and maintenance program. • Includes Type K thermocouple bead
probe
• Compatible with all standard mini-
Fluke 566 connector K-type thermocouples
• Data logging with a date/time stamp
• Soft rubber boot for increased
ruggedness
• User interface available in 6 languages

Fluke 568

Choose your language Select the measurement surface See complete measurement details
in seconds
Specifications
(Check the Fluke web for detailed specifications)

566 568
I n f r a r e d t e m p e r a t u r e r a n ge - 40 ° C t o 650 ° C - 40 ° C t o 800 ° C
Infrared accuracy < 0 °C : ± (1.0 °C + 0.1°/1 °C);
> 0 °C : ± 1 % or ± 1.0 °C, whichever is greater
Display resolution 0.1 °C
I n f r a r ed s p ec tr a l r es p on s e 8 µ m t o 14 µ m
Infrared response time < 500 msec
The Fluke 566 and included accessories I n p u t t e m p e r a t u r e r a n ge - 270 ° C t o 1372 ° C
I n pu t a c c u r a cy - 2 7 0 ° C t o - 4 0 ° C : ± (1 ° C + 0 . 2 ° /1 ° C )
-40 °C to 1372 °C: ± 1 % or 1 °C, whichever is greater
D : S (D i s t a n c e t o m e a s u r e m e n t s p o t s i z e ) 30: 1 50: 1
L a s e r s i gh t i n g S i n gl e - p o i n t l a s e r < 1 m w o u t p u t C l a s s 2 (I I ) o p e r a t i o n , 6 3 0 n m t o 6 7 0 n m
Minimum spot size 19 mm
E m i s s iv i ty a dju s tm en t B y b u i l t - i n t a b l e o f c o m m o n m a t e r i a l s o r d i gi t a l l y a d j u s t a b l e
from 0.10 to 1.00 by 0.01
D a t a l o ggi n g w i t h D a t e /T i m e s t a m p 20 p oi n t s 99 p oi n t s
P C i n t e r f a c e a n d c a bl e N on e U S B 2 . 0 w i t h F l u k e V i ew ®
Forms software
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix 98 x 96 pixels with function menus
B a c k l i gh t Tw o l ev e l s , n o r m a l a n d e x t r a br i gh t f o r d a r k e r e n v i r o n m e n t s
Trigger Lock Yes
S w i t c h a bl e b e t w e e n C e l s i u s a n d F a h r e n h e i t Y es

The Fluke 568 and included accessories Power: 2 AA/LR6 Batteries (566); 2 AA/LR6 Weight: 0.965 kg (566); 1.026 kg (568)
Batteries and USB for use with a PC (568) Size (HxLxW): 25.4 cm x 19.1 cm x 6.9 cm
Battery life: Used continuously; laser and Operating temperature: 0 °C to 50 °C
backlight on: 12 hours; laser and backlight off: Storage temperature: -20 °C to 60 °C
100 hours Two years warranty
Included accessories
FlukeView® Forms software (568 only), USB
cable (568 only), K-type thermocouple bead
probe, 2 AA batteries, hard carrying case,
quick start guide, and users manual. Recommended Accessories

Ordering information
Fluke 566 Infrared thermometer
Fluke 568 Infrared thermometer

H6 80PK-8 80PK-9 80PK-11 80PK-25 80PK-26


561
Multipurpose Thermometer

Combined Infrared and Contact Thermometer


The Fluke 561 combines the temperature • IR thermometer for quick
measurement functions that industrial, measurements up close or at a distance
electrical, and HVAC/R professionals • Single-point laser sighting
need, all in one tool. It measures both • Easy emissivity adjustment for
IR and contact temperature, replacing measuring pipes and ducts more
cient, accurately
and easy to use, saving you valuable time • Includes a Velcro pipe probe for super-
and effort. With the Fluke 561, you can heat and sub-cooling as well as other
take contact and ambient temperatures surface contact measurements
in the way that’s best for you. Use the IR • Also compatible with all standard mini-
thermometer to measure hot, moving, connector K-type thermocouples
electrically energized, and hard-to- • MIN, MAX and DIF temperature
reach objects instantly. Check motors, readings
insulation, breakers, radiant heating, • Lightweight (only 340 grams) and
pipes, corroded connections, and wires. portable
Plus, scan ducts, and other hard-to-reach • Includes measurement guide
oor—leave your ladder
in the truck. You can use the Fluke 561’s
Fluke 561 handy Velcro® pipe probe or, plug in any
industry standard, K-type mini-connector
thermocouple probe you already own.

Specifications

T e m p e r a t u r e r a n ge - 40° t o 550° C
D i s p l a y r es ol u ti on 0. 1° of r ea d i n g
D : S (D i s t a n c e t o s p o t s i z e ) 12: 1
E a s y em i s s i v i ty s el ec tor A d j u s t a bl e w i t h t h r e e s e t t i n gs : l ow (0 . 3 ), m e d i u m (0 . 7 ), h i gh (0 . 9 5 )
Display accuracy (Assumes ambient operating ± 1.0% of reading or ± 1°C, whichever is greater; below 0°C, ± 1°C, ± 1°/1°
temperature of 23° to 25°C)
R es p on s e ti m e 5 0 0 m S e c (9 5 % o r r e a d i n g)
R e p e a t a bi l i t y ± 0 . 5 % o f r e a d i n g o r ± 1 ° C , w h i c h ev e r i s gr e a t e r
S p ec tr a l f oc u s 8 µ m t o 14 µ m
L a s e r s i gh t i n g S i n gl e - p o i n t l a s e r
L a s er s h u tof f L a s e r t u r n s o f f a bov e a m bi e n t t e m p e r a t u r e o f 4 0 ° C
L a s e r p ow e r C l a s s 2 (I I ) o p e r a t i o n ; o u t p u t ‹ 1 m W , w a v e l e n gt h 6 3 0 n m t o 6 7 0 n m
R el a tiv e h u m i di ty 1 0 % t o 9 0 % R H n o n - c o n d e n s i n g, a t < 3 0 ° C
Po w e r 2 A A ba t t e r i e s (a l k a l i n e o r N i C D )
The Fluke 561 includes everything you need for D i s p l a y h ol d 7 s ec on d s
immediate inspections. B a ck l i t di s pl ay Y e s , L C D w i t h d u a l t e m p e r a t u r e s ( c u r r e n t a n d M A X / M I N / D I F / K T C ) , l o w b a t t e r y,
F/C indicator, and Scan/Hold options
Oper a ti n g tem per a tu r e 0° t o 50° C
S t o r a ge t e m p e r a t u r e - 20 t o 65° C
M A X , M I N , D I F tem per a tu r es Y es
Thermocouple type K mini-adapter input Yes, compatible with industry standard type K probes with mini-connector
Thermocouple type K Velcro pipe probe Yes, with a temperature range of 0° to 100°C and accuracy of ± 2.2°C
M e a s u r e m e n t gu i d e Y es

Battery Life (alkaline): 12 hours Weight: 340 grams


Size (HxLxW): 176,9 mm x 163,6 mm x 51,8 mm Two years warranty

Included accessories
Thermocouple K-type Velcro pipe probe,
hand carrying case, 2 AA batteries and user
manual with measurement guide.
Recommended Accessories
Ordering information
Fluke 561 HVACPro Thermometer

H6 80-PK-1 80PK-8 80PK-25


50 Series II Thermometers

Laboratory accuracy. Wherever you go.


The Fluke 50 Series II contact Additional features for the 53 and
thermometers offer fast response and 54 Series II:
laboratory accuracy (0.05% + 0.3°C) in • Data Logging up to 500 points of data
a rugged handheld test tool. with user adjustable recording interval
• Real time clock captures the exact time
• Large backlit dual display shows any of day when events occur
combination of T 1, T 2 (52 and 54 only), • Recall function allows logged data to be
T 1-T 2 (52 and 54 only) plus MIN, MAX, easily reviewed on the meter display
or AVG • IR communication port allows data to
• Relative time clock on MIN, MAX, and be exported to optional FlukeView®
AVG provides a time reference for major Temperature PC software
events
• Electronic Offset function allows
compensation of thermocouple errors
to maximize overall accuracy
• Readout in °C, °F, or Kelvin (K)
• Sleep mode increases battery life
• Battery door allows easy battery
replacement without breaking the
calibration seal

Features
51 II 52 II 53 II 54 II
T h er m oc ou p l e ty p es J, K , T , E J, K , T , E J, K , T , E , N , R , S J, K , T , E , N , R , S
Fluke 54 II N u m be r o f i n p u t s S i n gl e Dual S i n gl e Dual
T i m e s ta m p R el a tiv e T i m e R el a tiv e T i m e T i m e of D a y T i m e of D a y
Splash/Dust resistant
Dual display with backlight
Min/Max/Avg recording
(T 1-T 2) True differential
Data logging up to 500 points
IR data port for interface
to PC
Compatible with optional
FlukeView Software

Specifications
Fluke 51 II Fluke 52 II Fluke 53 II Temperature range:
J- t y p e T h e r m o c o u p l e s - 210° C t o 1200° C
K - ty p e T h er m oc ou p l es - 200° C t o 1372° C
T - ty p e T h er m oc ou p l es - 250° C t o 400° C
E - ty p e T h er m oc ou p l es - 150° C t o 1000° C
N - t y p e ** T h e r m o c o u p l e s - 200° C t o 1300° C
R ** a n d S - t y p e ** T h e r m o c o u p l e s 0° C t o 1767° C
Temperature accuracy
Above –100°C (-148°F):
Included Accessories J, K , T , E , a n d N - t y p e ** ± [ 0. 05% + 0. 3° C ]
Impact absorbing holster R ** a n d S - t y p e ** ± [ 0. 05% + 0. 4° C ]
Two bead probe thermocouples 80PK-1 (54+52) Below –100°C (-148°F):
One bead probe thermocouple 80PK-1 (51+53) J, K , E , a n d N - t y p e s ± [ 0. 20% + 0. 3° C ]
T- ty pe ± [ 0. 50% + 0. 3° C ]

Ordering Information **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type
Fluke 51 II Thermometer
Fluke 52 II Thermometer Battery life: 1000 hours typical, AA Weight: 0.4 kg
Fluke 53 II Thermometer Size (HxWxD): 173 x 86 x 38 mm Three Year Warranty
Fluke 54 II Thermometer
FVF-SC1 FlukeView Forms Software
including interface cable
Recommended Accessories

C25 80PK-26 80PK-25 FVF-SC1 TPAK


1523 and 1524
Reference Thermometers

A new standard in
accuracy and versatility.
Measure, graph and record three High accuracy
sensor types with one tool. The Fluke • PRTs: ±0.011 °C
1523/24 Reference Thermometer deliver • Thermocouples: ±0.24 °C for J,K,L,M
high accuracy, wide measurement • Precision thermistors: ±0.002 °C
range, logging, and trending, all in a
handheld tool you can take anywhere. Fast measurement
For top accuracy, a memory chip inside • PRTs: up to 0.45 seconds/sample
the probe connector feeds probe • Thermocouples: up to 0.3 seconds/
calibration information to the readout. sample
In addition, any thermocouple with • Precision thermistors: up to 0.3
a mini-thermocouple connector can seconds/sample
be read using the optional universal
thermocouple adapter. Choose the 1523 Two models
for single channel or the 1524 for dual • 1523: Single channel standard model;
channel measurement. memory for 25 readings & statistics
• 1524: Two channels; memory for 25
Three sensor types readings and statistics plus logging
• PRTs: –200 °C to 1000 °C 15,000 measurements; real-time clock
• Thermocouples –200 °C to 2315 °C for time and date stamps
Fluke 1524 Fluke 1523 • Precision thermistors: –50 °C to 150 °C

Features
1523 1524
Note: The 1523/24 are pictured with probes connected which may
be purchased seperately. S e n s o r Ty p e s PR T & R T D, T h e r m i s t or, a n d T h e r m oc ou p l e
T h e r m o c o u p l e Ty p e s B , C , E , J, K , L , M , N , R , S , T , U
N u m be r o f i n p u t s S i n gl e Dual
Data trending (graphing)
Graphical display with backlight
Included Accessories Min/Max/Avg/Standard deviation recording
cate of calibration, users High speed measurement
guide, CD-ROM (contains technical manual), RS-232 PC communications
12 V dc universal power supply, RS-232 cable, T1-T2 True differential
9940 I/O ToolKit software Data logging up to 15,000 points
Time and date stamp

Ordering Information
Fluke 1523* Reference Thermometer
Fluke 1524* Reference Thermometer
Fluke 1523-P1 Reference Thermometer, Specifi cations
PRT(–200 °C to 420 °C, 6.35
mm x 298 mm), Universal (Check the Fluke web for detailed specifications)
Thermocouple Adapter, TPAK,
Temperature range
and Case
T h er m oc ou p l e –2 0 0 ° C t o 2 3 1 5 ° C
Fluke 1524-P1 Reference Thermometer, PR T & R T D –2 0 0 ° C t o 1 0 0 0 ° C
PRT(–200 °C to 420 °C, 6.35 T h er m i s tor –5 0 ° C t o 1 5 0 ° C
mm x 298 mm), Universal Resolution and best accuracy
Thermocouple Adapter, TPAK, T h er m oc ou p l e 0. 01 ° , ±0 . 2 4 ° C
and Case PR T & R T D 0 . 0 0 1 ° , ±0 . 0 1 1 ° C
T h er m i s tor 0 . 0 0 1 ° , ±0 . 0 0 2 ° C
* Requires an optional probe Oper a ti n g tem per a tu r e –1 0 ° C t o 6 0 ° C
S t o r a ge t e m p e r a t u r e –2 0 ° C t o 7 0 ° C

Optional Accessories
2384-P INFO-CON Connector, PRT
Battery life (alkaline): 20 hours
(Gray Cap), Spare Power supply: Universal 12 Vdc
2384-T INFO-CON Connector, Size (HxWxD): 200 x 96 x 47 mm
Thermocouple (Blue Cap), Weight: 0.65 kg
Spare Warranty: 1 year
2373-LPRT RTD Adapter, Lemo to
Mini Grabbers (4-wire)
Recommended Accessories
Optional probes:
5616-12-P PRT, 6.35 mm x 298 mm,
–200 °C to 420 °C
5615-9-P PRT, 4.76 mm x 229 mm,
–200 °C to 420 °C
TPAK FLK80P1 FLK80P3 2384P and 2384T 2373-LTC
5610-9-P Thermistor, 3.2 mm x 229 mm, (80PK1 with universal (80PK-3A with universal Spare INFO-CON Adapters Universal TC adapter
0 °C to 100 °C thermocouple adapter) thermocouple adapter)

56
Thermal Imagers

Temperature changes can indicate problems in many everyday applica-


tions and a thermal imager makes it quick and easy to visually check
surface temperatures. Often problems can be discovered before contact
measurements even need to be made. Fluke offers a complete range of
handheld thermal imagers for both industrial and building diagnostic
applications. Models are available for any budget.
Ti Series Thermal Imagers

Find it, fi x it, fast! IR-Fusion ®


Technology: Infrared and
Temperature changes can indicate problems visual images fused together in one image
in many areas you see everyday, some
include: See things both ways - Infrared and
• Inside electrical distribution and service visual (visible light) images fused
(Switch gear, panels, controls, together communicating critical
fuses,transformers, receptacles, lighting, information faster and easier –
conductors, bus bars, motor control traditional infrared images are no longer
centers) enough. Patented IR-Fusion Technology,
®

• Motors, pumps and mechanical (Electric only available from Fluke, simultaneously
motors and generators, pumps, captures a digital photo and the infrared
compressors, evaporators, bearings, image and fuses them together taking
couplings, gearboxes, gaskets/seals, belts, the mystery out of IR image analysis.
rollers, disconnects)
• Process (Tanks and vessels, pipes, valves
and traps, reactors, process insulation)
• HVAC/R (air conditioning, heating, air
handlers, refrigeration)
• Outside electrical distribution - utilities
(Transformers, bushings, insulators,
transmission lines, other exterior
conductors, service connections, Full IR Picture-in-Picture Alpha Blending
disconnects, capacitor banks)

www.fluke.eu/ti

IR/Visible Alarm Full Visible Light

Overheating bearing cap Three-phase switch-gear


load imbalance

SmartView Software
®
Fluke SmartView software
®
is included with each Fluke
Thermal Imager. This powerful software is a modular
suite of tools that annotates, views, edits and analyzes
IR images.
Overheated motor Cool corner in a building It also generates fully customizable and professional-
looking reports in a few easy steps. The IR-Fusion
technology is fully supported.

Thermal imaging
application video
This video covers the principles of thermal
imaging and looks at using this powerful
troubleshooting technology in electrical,
electro-mechanical and process control
uke.co.uk/ti or
uke.eu/ti to see the video. FREE webinars/webcasts on
Thermal Imaging
Keep up-to-date on the latest troubleshooting
techniques. Attend a FREE Fluke webinar (web-based
seminar) about thermal imaging applications.
uke.eu/ti for more information.
CRange IRWindows

Increase the safety and speed of electrical


thermography
Infrared windows mount into panel doors ash risk associated
and covers for switchgear, transformers, with electrical thermography
bus bars and other live electrical ciency as thermographer
equipment, allowing Infrared, Ultraviolet, can work alone without being
Visual and IRfusion technologies to be accompanied by an electrician to isolate
used without exposing personnel to live and open panels
equipment. • Stay safety compliant with NFPA70E
All infrared windows from Fluke use and other safety protocols and leave the
the unique Quadraband™ multispectral panels closed
optic, allowing inspection with any • Extend the life of your equipment with
exibility both now and more frequent IR scans
in the future. • Easy to install
• Durable enough to withstand extreme
outdoor conditions yet practical for
indoor applications as well.

Specifications
(Check the Fluke web for detailed specifications)

FLK - 075- C LK T FLK - 100- C LK T


Optic Data
C r y s ta l I n s er t D i a m eter 75 m m 100 m m
V i ew i n g A p e r t u r e D i a m e t e r 68 m m 89 m m
V i ew i n g A p e r t u r e A r e a 3632 m m 2 6322 m m 2
T h i ck n es s 2 mm 4 mm
CLIRVU Coating
Shortwave IR Capable
Midwave IR Capable
Longwave IR Capable
Ultraviolet (UV) Capable
Visual Capable
Fusion Capable
General
Maximum Temperature
Gaskets 250º C

Included Accessories Body


Optic
659 º C
1400º C
Installation CD, self-adhesive drilling G a s k ets L ow S m o k e & F u m e ( L S F ) c o m p l i a n t s i l i c o n e
template, security access key, warranty IP rating IP65
statement. N E M A r a ti n g Ty p o 3 / 1 2 ( U L & C S A T h i r d Pa r t y C e r t i f i e d )
Vibration rating IEC60068-2-6
Humidity rating IEC60068-2-3
Ordering Information Pull out strength Up to 630 kg

FLK-075-CLKT 75mm C-Range IR Window,


Kwik Twist
FLK-100-CLKT 100mm C-Range IR Window, Warranty: Lifetime replacement against manufacturing defects
Kwik Twist
IP-200-UK Window Installation Kit
220/240V
Ti9/Ti10
Electrical Thermal Imagers

The rugged and affordable tools for


electricians and technicians
Get the full picture instantly with the • Enhanced problem detection and
Fluke Ti9/Ti10 thermal imagers. Built analysis capabilities with patent
for tough work environments, these pending
fully radiometric imagers are ideal for IR-Fusion ® Technology (Ti10)
detecting problems in a wide range of • Intuitive, three-button menu is easy to
equipment including switchgear, motor use ... simply navigate with the push of
control centers and lighting systems. a thumb
• Store more than 3.000 screen images
nd (.bmp format) or 1.200 fully radiometric
problems fast with its 160x120 sensor images (.IS2 format) on included 2 GB
• Even the smallest details become SD memory card
visible with the large, widescreen full • The Fluke Ti9 can be upgraded to a full
Fluke Ti10 color LCD display Fluke Ti10 with IR-Fusion at a later time.
eld use in harsh work
environments
- Engineered and tested to withstand a
2 meter drop
- Withstands dust and water – tested to
an IP54 rating
- Innovative protective lens cover
protects the lens when not in use

Specifications
(Check the Fluke web for detailed specifications)

Flu k e T i9 Flu k e T i10


Thermal imaging performance
D etec tor ty p e 1 6 0 x 1 2 0 F o c a l P l a n e A r r a y, u n c o o l e d m i c r o b o l o m e t e r
F i e l d o f v i ew (F O V ) 23 º h or i z on t a l x 17 º v er t i c a l
New S p a t i a l r e s o l u t i o n (I F OV )
M i n f oc u s d i s ta n c e
2. 5 m r a d
15 c m
T h e r m a l s e n s i t i v i t y (N E T D ) ≤0 . 2 ° C a t 3 0 ° C (2 0 0 m K )
M i n i m u m s p a n (A u t o /M a n u a l ) 1 0 ˚C / 5 ˚C
Fluke Ti9 Focus Manual
Visual imaging performance
Min focus distance 46 cm
On camera operating modes Picture-in-Picture and full screen IR
Visible light camera 1.3 MegaPixel
Temperature measurement
T e m p e r a t u r e r a n ge - 2 0 ˚C t o 2 5 0 ˚C
Accuracy ± 5 °C or 5%
M ea s u r em en t m od es C en ter p oi n t
Image presentation
D i gi t a l d i s p l a y 9 . 1 c m (3 . 6 " ) l a n d s c a p e c o l o r V G A (6 4 0 x 4 8 0 ) L C D
L C D ba c k l i gh t S e l e c t a bl e br i gh t o r a u t o
Pa l e t t e s I r o n bow , bl u e - r e d , h i gh c o n t r a s t , gr ey
Image and data storage
S t o r a ge m e d i u m 2 G B S D C a r d ( 3 0 0 0 . b m p I R i m a ge s / 1 2 0 0 . I S 2 i m a ge s )
Fi l e f or m a ts s u p p or ted JP G , JP E G , JP E , JF I F, B M P, G I F, D I B , P N G , T I F, a n d T I F F
Controls and adjustments
S et- u p c on tr ol s D a t e /t i m e , ˚C /˚F, l a n gu a ge
L a n gu a ge s e l e c t i o n E n g, ge r , f r e , s p a , p o r , i t a , s w e , f i n , r u s , c z e , p o l , t u r
I m a ge c o n t r o l s S m ooth a u to s c a l i n g a n d m a n u a l s c a l i n g
Power
B a tter y ty pe I n t e r n a l r e c h a r ge a b l e b a t t e r y N i M h ( i n c l u d e d )
B a tter y op er a ti n g ti m e 3 to 4 h ou r s c on ti n u ou s op er a ti on
Complete package

Included Accessories
SmartView ® software
2 GB SD card Battery life: 3 to 4 hours continuous operation
SD card reader Water and dust resistant: IP54
Rugged hard carrying case Size (HxWxD): 267 x 127 x 152 mm
Weight: 1.2 kg
Soft carrying case
Two Years Warranty
Hand strap
Rechargeable battery
AC charger/power supply Recommended Accessories
User manual
Training DVD

Ordering Information
Fluke Ti9 Electrical Thermal Imager Ti-Visor Ti-Car Charger Ti-TRIPOD
Fluke Ti10 Thermal Imager Sun Visor Car charger Tripod Mounting Base
Accessories
(for complete Ti Series)
(for complete Ti Series)
Ti25/Ti32
Industrial Thermal Imagers

New The ultimate tools for troubleshooting and


maintenance
The Fluke Ti32 combines a powerful NETD of 0.1ºC for the Ti25 and 0.05ºC for
320x240 sensor into the award winning, the Ti32 to view the smallest details.
rugged design of the Fluke Ti25, For added versatility and special
rst industrial grade, high eld-
performance thermal imager. The result swappable, rechargeable batteries. Use
is strikingly crisp, detailed images that, the optional telephoto and wide-angle
blended with patented IR-Fusion , are ® lens to bring distant and wide views into
sure to make a lasting impression. sharp focus.
The Fluke Ti32 and Ti25 have all the
features of the Fluke Ti10, but with an

Specifications
Fluke Ti32
(Check the Fluke web for detailed specifications)

Flu k e T i25 Flu k e T i32


Thermal imaging performance
D etec tor ty p e 1 6 0 x 1 2 0 F o c a l P l a n e A r r a y, u n c o o l e d 320 x 240 Focal Plane Array, uncooled
microbolometer microbolometer
F i e l d o f v i ew (F O V ) 23 º h or i z on t a l x 17 º v er t i c a l
S p a t i a l r e s o l u t i o n (I F OV ) 2. 5 m r a d 1. 25 m r a d
M i n f oc u s d i s ta n c e 15 c m
T h e r m a l s e n s i t i v i t y (N E T D ) ≤0 . 1 ° C a t 3 0 ° C (1 0 0 m K ) ≤0 . 0 5 ° C a t 3 0 ° C (5 0 m K )
M i n i m u m s p a n (A u t o /M a n u a l ) 2 . 5 ˚C / 5 ˚C
Focus Manual
Optional lenses
Telephoto infrared lens type
Wide-angle infrared lens type
Visual imaging performance
M i n f oc u s d i s ta n c e 46 c m
O n c a m er a op er a ti n g m od es Pi c t u r e - i n - Pi c t u r e a n d f u l l s c r e e n I R p l u s B l e n d i n g
Color Alarm High temperature alarm
V i s i bl e l i gh t c a m e r a 1 . 3 M e ga P i x e l 2 . 0 M e ga P i x e l
Temperature measurement
T e m p e r a t u r e r a n ge - 2 0 ˚C t o 3 5 0 ˚C - 2 0 ˚C t o 6 0 0 ˚C
Accuracy ± 2 °C or 2%
M ea s u r em en t m od es C en ter p oi n t a n d h ot a n d c ol d m a r k er s
Image presentation
Fluke Ti25 D i gi t a l d i s p l a y 9 . 1 c m (3 . 6 " ) l a n d s c a p e c o l o r V G A (6 4 0 x 4 8 0 ) L C D
L C D ba c k l i gh t S e l e c t a bl e br i gh t o r a u t o
Pa l e t t e s I r o n bow , B l u e - R e d , H i gh C o n t r a s t , A m be r , H o t Ironbow, Blue-Red, High Contrast, Amber,
Metal, Grey Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted
Palettes Ultra Contrast
Voice Annotation
Voice annotation
Image and data storage
S t o r a ge m e d i u m 2 G B S D C a r d ( 3 0 0 0 . b m p I R i m a ge s / 1 2 0 0 . I S 2 i m a ge s )
Fi l e f or m a ts s u p p or ted JP G , JP E G , JP E , JF I F, B M P, G I F, D I B , P N G , T I F, a n d T I F F
Controls and adjustments
Date/time, Cº/ºF, language
On screen emissivity correction
Set-up controls On-screen reflected background temperature compensation
On-screen transmission correction
L a n gu a ge s e l e c t i o n E n g, ge r , f r e , s p a , p o r , i t a , s w e , f i n , r u s , c z e , p o l , t u r
I m a ge c o n t r o l s S m ooth a u to s c a l i n g a n d m a n u a l s c a l i n g
Power
B a tter y ty pe I n t e r n a l r e c h a r ge a b l e b a t t e r y N i M h ( i n c l u d e d ) T w o r e p l a c e a b l e r e c h a r ge a b l e b a t t e r y p a c k s
(Lithium ion)
B a tter y op er a ti n g ti m e 3 to 4 h ou r s c on ti n u ou s op er a ti on 4 + h o u r s p e r ba t t e r y p a c k
Complete package

Included Accessories
SmartView ® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): Ti25: 267 x 127 x 152 mm
SD card reader Ti32: 277 x 122 x 170 mm
Rugged hard carrying case Weight: Ti25: 1.2 kg
Soft carrying case Ti32: 1.05 kg
Hand strap Two Years Warranty
Recommended Accessories
Rechargeable battery
AC charger/power supply
User manual
Training DVD

FLK-LENS/TELE1 FLK/LENS/WIDE Ti-Car Charger FLK-TI-SPB3 FLK-TI-SBC3


Ordering Information Telephoto Infrared Lens
(Ti32)
Wide-angle Infrared Lens
(Ti32)
Car charger Extra battery (Ti32) Charging base (Ti32)

Fluke Ti25 Industrial Thermal Imager


Fluke Ti32 Industrial Thermal Imager
TiRx/TiR
Thermal Imagers
for Building Inspection

Optimized for energy audits, restoration and


remediation
The affordable rugged Fluke TiRx and TiR - Innovative protective lens cover
Thermal Imagers are workhorse tools protects the lens when not in use
for the demands of building envelope, • Enhanced problem detection and
restoration and remediation, inspection analysis capabilities with patent pending
ng applications. Whether IR-Fusion ® Technology (TiR)
to perform energy audits, locate the • Intuitive, three-button menu is easy to
origins of construction problem or to use ... simply navigate with the push of a
nd roof leaks, the TiRx and TiR offer thumb
an economical solution for complete • Store more than 3.000 screen images
detection, analysis and documentation. (.bmp format) or 1.200 fully radiometric
images (.IS2 format) on included 2 GB SD
nd memory card
Fluke TiR problems fast with its 160x120 sensor • The Fluke TiRx can be upgraded to a full
• Even the smallest details become Fluke TiR with IR-Fusion at a later time.
visible with the large, widescreen full
color LCD display
eld use in harsh work
environments
- Engineered and tested to withstand
a 2 meter drop
- Withstands dust and water – tested
to an IP54 rating

Specifications
(Check the Fluke web for detailed specifications)

New Flu k e T iR x Flu k e T iR


Thermal imaging performance
D etec tor ty p e 1 6 0 x 1 2 0 F o c a l P l a n e A r r a y, u n c o o l e d m i c r o b o l o m e t e r
F i e l d o f v i ew (F O V ) 23 º h or i z on t a l x 17 º v er t i c a l
S p a t i a l r e s o l u t i o n (I F OV ) 2. 5 m r a d
Fluke TiRx M i n f oc u s d i s ta n c e 15 c m
T h e r m a l s e n s i t i v i t y (N E T D ) ≤0 . 1 ° C a t 3 0 ° C (1 0 0 m K )
M i n i m u m s p a n (A u t o /M a n u a l ) 2 . 5 ˚C / 5 ˚C
Focus Manual
Visual imaging performance
Min focus distance 46 cm
On camera operating modes Picture-in-Picture and full screen IR
Visible light camera 1.3 MegaPixel
Temperature measurement
T e m p e r a t u r e r a n ge - 2 0 ˚C t o 1 0 0 ˚C
Accuracy ± 5 °C or 5%
M ea s u r em en t m od es C en ter p oi n t
Image presentation
D i gi t a l d i s p l a y 9 . 1 c m (3 . 6 ” ) l a n d s c a p e c o l o r V G A (6 4 0 x 4 8 0 ) L C D
L C D ba c k l i gh t S e l e c t a bl e br i gh t o r a u t o
Pa l e t t e s I r o n bow , bl u e - r e d , h i gh c o n t r a s t , gr ey
Image and data storage
S t o r a ge m e d i u m 2 G B S D C a r d ( 3 0 0 0 . b m p I R i m a ge s / 1 2 0 0 . I S 2 i m a ge s )
Fi l e f or m a ts s u p p or ted JP G , JP E G , JP E , JF I F, B M P, G I F, D I B , P N G , T I F, a n d T I F F
Controls and adjustments
Set-up controls Date/time, ˚C/˚F, language
L a n gu a ge s e l e c t i o n E n g, ge r , f r e , s p a , p o r , i t a , s w e , f i n , r u s , c z e , p o l , t u r
I m a ge c o n t r o l s S m ooth a u to s c a l i n g a n d m a n u a l s c a l i n g
Power
Complete package
B a tter y ty pe I n t e r n a l r e c h a r ge a b l e b a t t e r y N i M h ( i n c l u d e d )
B a tter y op er a ti n g ti m e 3 to 4 h ou r s c on ti n u ou s op er a ti on

Included Accessories
SmartView ® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): 267 x 127 x 152 mm
SD card reader Weight: 1.2 kg
Rugged hard carrying case Two Years Warranty
Soft carrying case
Hand strap
Recommended Accessories
Rechargeable battery
AC charger/power supply
User manual
Training DVD

Ti-Visor Ti-Car Charger Ti-TRIPOD


Sun Visor Car charger Tripod Mounting Base
Ordering Information (for complete Ti Series) Accessories
(for complete Ti Series)
Fluke TiRx Inspector Thermal Imager
Fluke TiR Thermal Imager
TiR1/TiR32
Thermal Imagers
for Building Diagnostics

New
The top professional’s choice
The TiR1 and TiR32 Thermal Imagers are TiR32 to identify even small temperature
the top professional’s choice for building differences that could indicate problems.
diagnostics. With its 320 x 240 sensor, For added versatility and special
the TiR32 delivers the clear, crisp images applications, the TiR32 includes dewpoint
nd problems fast. The Fluke eld-swappable,
TiR1 and TiR32 have all the features rechargeable batteries. Use the optional
of the Fluke TiR, but with an NETD of telephoto and wide-angle lens to bring
0.07ºC for the TiR1 and 0.05ºC for the distant and wide views into sharp focus.

Fluke TiR32
Specifications
(Check the Fluke web for detailed specifications)

Flu k e T iR 1 Flu k e T iR 32
Thermal imaging performance
D etec tor ty p e 1 6 0 x 1 2 0 F o c a l P l a n e A r r a y, u n c o o l e d 320 x 240 Focal Plane Array, uncooled
microbolometer microbolometer
F i e l d o f v i ew (F O V ) 23 º h or i z on t a l x 17 º v er t i c a l
S p a t i a l r e s o l u t i o n (I F OV ) 2. 5 m r a d 1. 25 m r a d
M i n f oc u s d i s ta n c e 15 c m
T h e r m a l s e n s i t i v i t y (N E T D ) ≤0 . 0 7 ° C a t 3 0 ° C (7 0 m K ) ≤0 . 0 5 ° C a t 3 0 ° C (5 0 m K )
M i n i m u m s p a n (A u t o /M a n u a l ) 2 . 5 ˚C / 3 ˚C
Focus Manual
Optional lenses
Telephoto infrared lens type
Wide-angle infrared lens type
Visual imaging performance
M i n f oc u s d i s ta n c e 46 c m
O n c a m er a op er a ti n g m od es Pi c t u r e - i n - Pi c t u r e a n d f u l l s c r e e n I R p l u s B l e n d i n g
Color Alarm Dewpoint alarm
V i s i bl e l i gh t c a m e r a 1 . 3 M e ga P i x e l 2 . 0 M e ga P i x e l
Temperature measurement
T e m p e r a t u r e r a n ge - 2 0 ˚C t o 1 0 0 ˚C - 2 0 ˚C t o 1 5 0 ˚C
Fluke TiR1
Accuracy ± 2 °C or 2%
M ea s u r em en t m od es C en ter p oi n t a n d h ot a n d c ol d m a r k er s
Image presentation
D i gi t a l d i s p l a y 9 . 1 c m (3 . 6 " ) l a n d s c a p e c o l o r V G A (6 4 0 x 4 8 0 ) L C D
L C D ba c k l i gh t S e l e c t a bl e br i gh t o r a u t o
Pa l e t t e s I r o n bow , B l u e - R e d , H i gh C o n t r a s t , A m be r , H o t Ironbow, Blue-Red, High Contrast, Amber,
Metal, Grey Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted
Palettes Ultra Contrast
Voice Annotation
Voice annotation
Image and data storage
S t o r a ge m e d i u m 2 G B S D C a r d ( 3 0 0 0 . b m p I R i m a ge s / 1 2 0 0 . I S 2 I R - F u s i o n i m a ge s )
Fi l e f or m a ts s u p p or ted JP G , JP E G , JP E , JF I F, B M P, G I F, D I B , P N G , T I F, a n d T I F F
Controls and adjustments
Date/time, Cº/ºF, language
On screen emissivity correction
Set-up controls On-screen reflected background temperature compensation
On-screen transmission correction
L a n gu a ge s e l e c t i o n E n g, ge r , f r e , s p a , p o r , i t a , s w e , f i n , r u s , c z e , p o l , t u r
I m a ge c o n t r o l s S m ooth a u to s c a l i n g a n d m a n u a l s c a l i n g
Power
B a tter y ty pe I n t e r n a l r e c h a r ge a b l e b a t t e r y N i M h ( i n c l u d e d ) T w o r e p l a c e a b l e r e c h a r ge a b l e b a t t e r y p a c k s
(Lithium ion)
Complete package B a tter y op er a ti n g ti m e 3 to 4 h ou r s c on ti n u ou s op er a ti on 4 + h o u r s p e r ba t t e r y p a c k

Included Accessories
SmartView ® software Water and dust resistant: IP54
2 GB SD card Size (HxWxD): TiR1: 267 x 127 x 152 mm
SD card reader TiR32: 277 x 122 x 170 mm
Rugged hard carrying case Weight: TiR1: 1.2 kg
Soft carrying case TiR32: 1.05 kg
Hand strap Two Years Warranty
Rechargeable battery Recommended Accessories
AC charger/power supply
User manual
Training DVD

Ordering Information
Fluke TiR1 Thermal Imager for Building FLK-LENS/TELE1 FLK/LENS/WIDE Ti-Car Charger FLK-TI-SPB3 FLK-TI-SBC3
Diagnostics Telephoto Infrared Lens Wide-angle Infrared Lens Car charger Extra battery (Ti32) Charging base (Ti32)
(Ti32) (Ti32)
Fluke TiR32 Thermal Imager for Building
Diagnostics
Laser Distance Meters

The Fluke Laser Distance Meters bring you the most advanced
measuring technology. Unlike ultrasonic distance meters with laser
pointers, these meters use a precision narrow laser beam that can
avoid the common errors caused by extraneous objects near
measurement targets.
421D, 416D, 411D
Laser Distance Meters

Professional-grade laser distance


New measuring tools that are fast, easy to use,
and fi t in your pocket.
The Fluke laser distance meters bring you These compact and handy Fluke distance
the most advanced measuring technology. meters are designed for indoor, and limited
These meters are fast, accurate, durable, and outdoor applications. Addition, subtraction,
easy to use — just point and shoot. Their area, and volume calculations could not be
straightforward design and easy, one-button simpler. The extra bright laser is clearly
operation mean you spend less time visible so you can see your targeting point
measuring. Unlike ultrasonic distance meters even if an object is hard-to-reach or distant.
with laser pointers, the Fluke 421D, 416D The Fluke 421D, 416D and 411D have a large
and 411D use a precision narrow laser beam LCD screen and buttons positioned for one-
that can avoid the common errors caused by handed measurements.
extraneous objects near measurement
targets.

Fluke 421D Features


411D 416D 421D
Reduction of estimation errors, saving both time and money
Instant measurement with one-button operation
Easy targeting with bright laser
Quick calculation of area (square footage) and volume
Easy addition and subtraction of measurements
Improved battery life from automatic shut-off feature
Pythagoras calculation for determining distance indirectly from two other
measurements
Pouch
Ability to view more with large, 3-line display with backlight
Abi l i ty to mea s ure up to 30 m 60 m 10 0 m
S tora ge ca pa ci ty of mea s urements for qui ck reca l l of di s ta nce - 10 20
MIN/MAX function
Enhanced Pythagoras calculation for determining distance indirectly from
three other measurements
Audible feedback of on and off modes
Fluke 411D Fluke 416D Strong environment protection with IP54 (water spray & dust proof) sealing
Audible feedback for taking room angle and incremental measurements
± 45° Tilt sensor for taking indirect measurements in hard to reach areas
Tripod mode allows you to mount to a tripod for measuring long distances
Built in light sensor for activating the backlight saving battery life
Corner angle feature, allows you to determine the angle of a corner

Specifi cations
(Check the Fluke web for detailed specifications)

Fluke 411D Fluke 416D Fluke 421D


Range (for extended distances, use a target plate) 30 m 60 m 100 m
Accura c y ± 3 mm ± 1. 5 mm ± 1. 5 mm
Mea s urement uni ts 0 0 .0 0 0 m 0 0 .0 0 0 m 0 0 .0 0 0 m
411D/62 Kit Mea s urement s tora ge 10 l oca ti ons 2 0 l oca ti ons
Combo kit includes:
Backlight
- Fluke 62 Mini IR Thermometer
Automa ti c pow er off After 18 0 s econds After 18 0 s econds After 3 6 0 s econds
- Fluke 411D Laser Distance Meter
- Soft pouch for each model
Operating temperature: 0°C to 40°C Size (HxWxD): 411D: 123 mm x 50 mm x 26 mm
Storage temperature: -25°C to 70°C 416D: 135 mm x 46 mm x 31 mm
Operating altitude: up to 3500 m 421D: 127 mm x 52 mm x 25 mm
Battery Life: 411D: up to 3000 readings Weight: 411D: 0.150 kg
Included Accessories 416D, 421D: up to 5000 readings 416D: 0.110 kg
Two AAA batteries, Users manual on CD, 421D: 0.125 kg
Quick start guide, Nylon carrying case, Warranty: 2 years
Wrist wrap (421D)

Ordering Information
Fluke 411D Laser Distance Meter
Fluke 416D Laser Distance Meter
Fluke 421D Laser Distance Meter
Indoor Air Quality Tools

In response to the growing importance of air quality in buildings,


workplaces and homes, Fluke offers you a range of tools that monitor
temperature, humidity, air velocity, particulate, and carbon monoxide
levels. These tools help you to quickly and easily troubleshoot and
cient operation of
heating, ventilation and air conditioning systems.
975 AirMeter

Combined inspection tool for complete air


quality inspections
ve air • Simultaneously measures, logs, and
monitoring tools into one, rugged and displays temperature, humidity, CO 2,
easy-to-use handheld tool. Use the Fluke and CO on a bright, backlit LCD display
cient operation of ow and velocity
heating, ventilation and air conditioning measurements with available probe
systems, and test for dangerous carbon • Min/Max/Average on all measured and
monoxide leaks in all types of buildings. calculated readings
• Audible and visual threshold alarms
• Multi-language user interface
• Extensive discrete or continuous data
logging capacity, down-loadable to PC
via USB interface

S p e c if ic a t io n s
(Check the Fluke web for detailed specifications)

Fe a tu r e R a n ge D i s p l a y r e s o l u ti o n A c c u r a cy
Measured specifications
T em per a tu r e - 20 ° C t o 60 ° C 0. 1 ° C ± 0. 9 ° C f r om 40 ° C t o 60 ° C
± 0.5 °C from 5 °C to 40 °C
± 1.1 °C from -20 °C to 5 °C
R el a tiv e h u m i di ty 10 % t o 90 % R H n on - 1% ± 2 % RH (10 % RH
condensing to 90 % RH)
A i r v el oc i ty 50 f p m t o 3000 f p m 1 fpm 4 % or 4 fpm*
0.25 m/sec to 15 m/sec 0.005m/sec 3 % or 0.015 m/sec*
whichever is greater
*Accuracy specification only valid
for velocity readings above 50 fpm.
CO 2 0 to 5000 ppm 1 ppm Warm up time 1 min
(5 minutes for full specification)
2.75 % + 75 ppm
CO 0 t o 500 p p m 1 ppm ± 5 % or ± 3 p p m ,
whichever is greater,
@ 20 °C and 50 % RH
Calculated specifications
D ew p o i n t t e m p e r a t u r e - 44 ° C t o 57 ° C 0. 1 ° C ± 1 ° C w h en t em p : - 20 ° C t o 60 ° C
RH: 40 % to 90 %
Fluke 975 ± 2 °C when temp: -20 °C to 60 °C
RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
W e t bu l b t e m p e r a t u r e - 16 ° C t o 57 ° C 0. 1 ° C ± 1.2 °C when RH: 20 % to 90 %
temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
V o l u m e f l ow r a t e ( i n a d u c t ) 0 t o 3 , 9 6 5 M 3/m 0 to 0.001 M 3/min (1 cfm) N/A: The volume flow
140,000 cfm) calculation will be a simple average
of the data points times the
duct area
% outside air (based on temperature) 0 to 100 % 0.1 % N/A
% outside air (based on CO 2
) 0 t o 100 % 0. 1 % N /A

Operating temperature Shock and vibration: MIL-PRF-28800F, Class 2


(CO and CO 2 sensors): -20 °C to 50 °C Battery: Rechargeable Li-Ion (primary), three-
Operating temperature AA (backup)
(all other functions): -20 °C to 60 °C Weight: 0.544 kg
Storage temperature: -20 °C to 60 °C Size (HxWxD): 28.7 cm x 11.43 cm x 5.08 cm
Humidity: 10% to 90% Data logging: 25,000 records (continuous),
Altitude: Up to 2000 m 99 records (discrete)
Multilanguage interface: English, French,
Spanish, Portuguese and German
Two-year warranty
Included Accessories
A4 alkaline batteries (3), Users Manual,
Calibration Cap, FlukeView Forms Software,
Power Adapter, International Power Plugs,
Air Velocity Probe (Fluke 975V only)

Ordering Information R e c o m m e n d e d A c c e s s o r ie s
Fluke 975 AirMeter
Fluke 975V AirMeter with Velocity
975CK Airmeter Calibration Kit
975R Regulator
975VP Air Velocity Probe
975VP
AirMeter Velocity Probe
922 Airflow Meter
Measures pressure, air flow and velocity for
maintaining balanced and comfortable
ventilation
ow • Provides differential and static pressure,
measurements easy by combining ow readings
ow, and velocity into a • Convenient colored hoses help you
single, rugged meter. Compatible with properly diagnose pressure readings
most Pitot tubes, the Fluke 922 allows • Bright, backlit display for clear viewing
technicians to conveniently enter in all environments
their duct shape and dimensions for • Min/Max/Average/Hold functions for
maximum measurement accuracy. easy data analysis
• Auto power off saves battery life
Use the Fluke 922 to: Ensure proper air
ow balance and maintain a comfortable
environment; measure pressure drops
lters and coils; match ventilation
to occupant loads; monitor indoor vs.
outdoor pressure relationships and
manage the building envelope; and
perform duct traversals for accurate
ow readings.
Specifications
(Check the Fluke web for detailed specifications)

Fe a tu r e R a n ge R e s o l u ti o n A c c u r a cy
Operating Specifications
A i r Pr e s s u r e ± 4 0 0 0 Pa s c a l s 1 Pascal ± 1% +1 Pascal
± 16 in H 2O 0.001 in H 2O ± 1% + 0.01 in H 2O
± 400 mm H 2O 0.1 mm H 2O ± 1% + 0.1 mm H 2O
± 40 mbar 0.01 mbar ± 1% +0.01 mbar
± 0.6 PSI 0.0001 PSI ± 1% + 0.0001 PSI
A i r V el oc i ty 250 t o 16, 000 f p m 1 fpm ± 2.5 % of reading at 10 m/s
1 to 80 m/s 0.001 m/s (2000 p/min)
Air Flow (Volume) 0 to 99,999 cfm 1 cfm Accuracy is a function of
Fluke 922
0 to 99,999 m 3/hr 1 m 3/hr velocity and duct size
0 to 99,999 l/s 1 l/s
T em per a tu r e 0 ° C t o 50 ° C 0. 1° C ± 1 % + 2 °C

G e n e r a l S p e c if ic a t io n s
General specifications
Operating Temperature 0 ºC to +50 ºC
S t o r a ge T e m p e r a t u r e - 4 0 º C t o +6 0 º C
Operating Relative Humidity Non condensing (<10 ºC)
90% RH (10 ºC to 30 ºC)
75% RH (30 ºC to 40 ºC)
45% RH (40 ºC to 50 ºC) Without Condensation
I P R a ti n g I P40
Oper a ti n g A l ti tu de 2000 m
S t o r a ge A l t i t u d e 12000 m
EM I , R FI , EM C M eet s r eq u i r em en t s f or E N 61326- 1
V i br a t i o n M I L - P R E F - 2 8 8 0 0 F, C l a s s 3
Max Pressure at Each Port 10 PSI

Data Storage: 99 readings


Size (HxWxD): 175 x 775 x 419 mm
Included Accessories Weight: 0.64 kg
Fluke 922: Two Rubber Hoses, Wrist Strap, Four Battery: Four AA batteries
AA Batteries 1.5 V Alkaline, Users Manual and Battery Life: 375 hours without backlight,
Soft Carrying Case 80 hours with backlight
Fluke 922 Kit Includes: Fluke 922 Airflow Meter, Two Year Warranty
30.48 cm Pitot tube, ToolPak, Two Rubber
Hoses, Wrist Strap, Four AA Batteries 1.5 V
Alkaline, Users Manual and Hard Carrying Fluke 922/Kit
Case R e c o m m e n d e d A c c e s s o r ie s
Ordering Information
Fluke 922 Air Flow Meter
Fluke 922/Kit Airflow Meter with
30.48 cm Pitot Tube
PT12 TPAK
Pitot Tube, 30.48 cm Toolpak
971 Temperature Humidity Meter
Carbon Monoxide Meters

Fluke 971
Temperature Humidity Meter
Quickly take accurate humidity and • Simultaneously measures humidity and
temperature readings in the air. temperature
Temperature and humidity are two • Measures dew point and wet bulb
important factors in maintaining • 99 record storage capacity
optimal comfort levels and good indoor • Min/Max/Avg Data Hold
air quality. The Fluke 971 is invaluable • Ergonomic design with built-in belt clip
for facility maintenance and utility and protective holster
technicians, HVAC-service contractors, • Backlit, dual readings display
and specialists who assess indoor air • Twist-open protective cap
quality (IAQ). Lightweight, rugged, and • Low battery indicator
easy to hold, the Fluke 971 is the perfect
tool for monitoring problem areas.

Specifications

T e m p e r a t u r e r a n ge - 2 0 ºC t o 6 0 ºC
Temperature accuracy
0 ºC to 45 ºC ± 0.5 0C
-20 ºC to 0 ºC and 45 ºC to 60 ºC ± 1.0 ºC
R es ol u ti on 0 . 1 ºC
Response time (temperature) 500 ms
Temperature sensor type NTC
Relative humidity range 5% to 95% R.H.
Fluke 971 Relative humidity accuracy
10% to 90% R.H. @ 23 ºC ± 2.5 % R.H.
<10%, >90% R.H. @ 23 ºC ± 5.0 % R.H.
H u m i d i ty s en s or E l ec tr on i c c a p a c i ta n c e p ol y m er f i l m s en s or
Other useful tools D a t a s t o r a ge 99 p oi n t s
Response time (humidity) For 90% of total range - 60 sec with 1 m/s air movement

Operating temperature: Safety: Complies with EN61326-1


Temperature: -20 °C to 60 °C Weight: 0.188 kg
Humidity: 0 °C to 60 °C Size (HxWxD): 194 mm x 60 mm x 34 mm
Storage temperature: : -20 °C to 55 °C One Year Warranty
Battery life: 4 AAA alkaline, 200 hours
Fluke 561 Fluke 416D
Combined Contact Laser Distance Meter
and Non-contact See page 65.
Thermometer Carbon Monoxide Meters
See page 54.

CO-220 Carbon Monoxide Meter


The CO-220 Carbon Monoxide Meter makes it easy to take quick Fluke CO-220
and accurate measurements of CO levels. A large, backlit LCD
Included Accessories display shows CO levels from 0 to 1000 PPM. The MAX Hold
Fluke CO-220: C50 soft carrying case and
function stores and displays the maximum CO level.
battery
1 year warranty.
Ordering Information
Fluke 971 Temperature Humidity
Meter
Fluke CO-220 Carbon Monoxide Meter
CO-205 Aspirator Kit CO-205 Aspirator Kit
Allows flue gas samples up to 371°C to be drawn with the
CO-220 for carbon monoxide measurement. Fluke CO-205
1 year warranty.
983 Particle Counter /
RLD2 Leak Detector Flashlight

Easy to use tool for troubleshooting and


maintaining indoor air quality
The Fluke 983 Particle Counter • Simultaneously measure and display 6
simultaneously measures and displays channels of particle sizes, temperature
six channels of particle size distribution, and humidity
temperature and humidity. This compact, • Measure particle size down to 0.3 µm
lightweight, self-contained tool allows • Selectable sample time, count data,
for one-handed operation. As the Fluke programmable delay
983 doesn’t require level holding, it can • Store 5000 records of date, time, counts,
make accurate measurements in any relative humidity, temperature, sample
position. The 8 hour rechargeable battery volumes, alarms and location label
together with a large 5000 sample record • Upload stored data to a PC with
allows for complete air quality surveys in included software
one go. The Fluke 983 is the ideal tool for • Compact, self-contained package allows
determining size distribution of airborne for one-handed operation
particles or tracking down a particle • Intuitive, easy-to-use user interface
source. uids to
ll
• Backlit LCD for use in any lighting
condition

Specifications

6 size channels 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm


Flow rate 0.1 cfm (2.83 L/min) controlled by internal pump
Count modes Concentration, totalize, audio
Counting efficiency 50 % @ 0.3 µm; 100 % for particles > 0.45 µm (per JIS B9921:1997)
Zero count 1 count/5 minute (per JIS B9921:1997)
Fluke 983
Coincidence loss 5 % at 56,000 particles per m 3

Relative humidity ± 7 %, 20 % to 90 %, non-condensing


Temperature ± 3 °C, 10 °C to 40 °C
Data storage 5000 sample records (rotating buffer) of date, time, counts, relative humidity,
temperature, sample volumes, alarms, label
A larm s C o u n t s , l o w b a t t e r y, s e n s o r f a i l
Delay time 0 to 24 hours
Sample inlet Isokinetic probe
Interface RS-232 and RS-485 via RJ-45
Calibration PSL particles in air (NIST traceable)

Operating temperature: 10 °C to 40 °C, 20 % to Rechargeable battery: NiMH, 4.8V at 4.5 Ah;


90 % relative humidity, non-condensing replaceable
Storage temperature: -10 °C to 50 °C, up to Size (HxWxD): 209 mm x 114 mm x 57 mm
90 % relative humidity, non-condensing Weight: 1 kg
Power: AC adapter, 90 to 250 V AC, 50 to 60 Hz Warranty: 1 year
Battery life/recharge time: 8 hours/2 hours

Included Accessories RLD2 Leak Detector Flashlight


Fluke 983:
Certificate of Calibration (NIST)
Isokinetic probe
Zero count filter New RLD2 Leak Detector Flashlight.
Windows-compatible software download Leak detection made easy. The compact RLD2
utility uncovers refrigerant leaks instantly. Use the UV
DB9 to RS-232 adapter and cable nd the leakage area, then, use the laser
High purity tubing pointer to pinpoint the exact leak location.
1/8 in. hose barb adapter
Power supply • Six UV LEDs detect leak detection dyes
Operation manual • Laser pointer clearly locates center of the UV
Hard molded carrying case eld for accuracy
Fluke RLD2: Key chain carabiner and batteries. ashlight with 100,000 hour LED life
• Operating temperature 0ºC to 50ºC
Ordering Information ashlight, UV light, laser
Fluke 983 Particle Counter light, UV/laser light combination
Fluke RLD2 Leak Detector Flashlight • One year warranty
ScopeMeter ® Test Tools

With the original ScopeMeter, we transformed the oscilloscope category


beyond recognition, and we still lead the way today. From rugged
solutions for industrial applications to full-colour models that pack top-
cations into hand-held, battery powered
instruments. In short, ScopeMeter provides you with unmatched speed,
performance and analysis power while working on site.
ScopeMeter® Test Tools

Oscilloscopes for field applications

Features
225C 215C 199C 196C 192C 125 124 123
LDC Display C ol or B /W
Persistence
Waveform reference
Automatic pass fail testing
Cursors and zoom Cursors
Connect and View triggering
Video triggering with line selector
Selectable pulse width triggering
Capture and replay of last 100 screens
D u a l i n p u t T r e n d Pl ot W i th c u r s or s a n d Z oom
M em or y f or s c r een s a n d s et- u p s 10 s c r een s a n d s et u p 20 20 10
Recorder memories, each can store 100 scope screens, 2 recorder memories
a ScopeRecord or a TrendPlot

The ScopeMeter 190C Series of high 1000V Independently floating isolated outputs

performance oscilloscopes have Meter measurements: VAC RMS, VAC+DC, Ohms,


Continuity, Diode, Amps, Temp. (ºC, ºF)
bandwidth of 60, 100 and 200 MHz and
Waveform mathematics: A+B, A-B, AxB, A versus B
sample rates up to 2.5 GS/s. (X-Y mode)
These instruments offer a high- Frequency Spectrum Analysis using FFT 2)

resolution color display that has a Power measurements and V PWM

Capacitance and frequency measurements -/ -/ -/ -/ -/ / / /


fast update rate, waveform pass/fail Bus Health Test function
testing and a digital persistence mode Rugged, dust and drip proof case (IP51)
– making the analysis of complex and PC and printer interface via optically isolated RS- 1) 1) 1) 1) 1) 1) 1) 1)
dynamic signals much easier. 232/USB cable
FlukeView ® for Windows ® Software (SW90W) 1) 1) 1) 1) 1) 1) 1) 1)

For industrial electronic or electro


mechanical applications, the 120 Series
Industrial ScopeMeter, with a 20 or Standard equipped 1) Optional 2) Harmonics mode

40 MHz bandwidth and Connect-and-


View™ triggering for an instant, stable
display will get the job done.
Specifications
(Check the Fluke web for detailed specifications)

225C 215C 199C 196C 192C 125 124 123


Oscilloscope specifications
B a n dw i d t h 200 M H z 100 M H z 200 M H z 100 M H z 60 M H z 40 M H z 20 M H z
M a x . r ea l ti m e s a m pl e r a te 2 . 5 G S /s 1 G S /s 2 . 5 G S /s 1 G S /s 500 25 MS/s
MS/s
I n pu t s en s i tiv i ty 2 m V / d i v. . . . 1 0 0 0 V / d i v 5 m V / d i v. . . . 5 0 0 V / d i v.
T i m e b a s e r a n ge 5 n s / d i v. . . . 2 m i n / d i v. 1 0 n s / d i v. 10 ns/div. ...1min/div. 20
...2 min/ ns/div. ...1
div. min/div.
I n p u t s a n d d i gi t i z e r s 2 p l u s e x t e r n a l t r i gge r /D M M i n p u t 2
Independently floating isolated outputs Up to 1000 V between inputs, references and ground
Max. record length...
... in Scope mode: 3000 points per input 512 min/max points per input
... in ScopeRecorde mode: 27.500 points per input or more (5 ms/div. to
2 min/div.)
G l i tch c a ptu r e U p t o 3 n s u s i n g P u l s e W i d t h t r i gge r i n g; 40 ns
50 ns peak detect at 5 µs/div. to 1 min/div.
Scope measurements cursors + 26 automatic 26
7 cursor measurements, 30 automatic measurements automatic
Automatic Vrms and watts measurement on cursor ...plus
limited part of waveform power
measure-
ments and
Vpwm
T r u e R M S m u l ti m eter 5 0 0 0 c o u n t s , s i n gl e i n p u t 5000 c ou n t s , d u a l i n p u t
General specifications
L i n e p ow e r A d a p t e r / b a t t e r y c h a r ge r i n c l u d e d ( B C 1 9 0 ) A d a p t e r / b a t t e r y c h a r ge r i n c l u d e d
(PM8907)
B a t t e r y (i n s t a l l e d ) >3 , 5 h r N i - M H ( B P 1 9 0 ) 7 h r N i - M H (B P 1 2 0 M H )
Size 256 x 169 x 64 m m 232 x 115 x 50 m m
Weight 2 kg 1. 2 k g
S a f e t y c e r t i f i e d (E N 6 1 0 1 0 - 1 ) 1000 V C AT I I / 600 V C AT I I I 600 V C AT I I I
Warranty 3 years on main products and 1 year on accessories
ScopeMeter® 120 Series

Three-in-one simplicity
The compact ScopeMeter 120 Series stable, reliable and repeatable display
is the rugged solution for industrial of virtually any signal - including
troubleshooting and installation motordrive and control signals - without
applications. It’s a truly integrated test touching a button. Signal changes
tool, with oscilloscope, multimeter and are instantly recognized and settings
“paperless” recorder in one affordable, adjusted for - once again - a stable
easy-to-use instrument. Find answers to display.
problems in machinery, instrumentation,
control and power systems quickly and Use TrendPlot™ to help find
easily. intermittents fast
nd are those
• Dual-input 40 MHz or 20 MHz digital that happen only once in a while:
oscilloscope intermittents. They can be caused by
Fluke 125 • Two 5,000 counts true-RMS digital bad connections, dust, dirt, corrosion
multimeters or simply broken wiring or connectors.
• A dual-input TrendPlot™ recorder You may not be around to see it – your
• Bus Health Test for industrial bus Fluke ScopeMeter will. In this “paperless
systems (Fluke 125) recorder” mode,
• Connect-and-View™ trigger simplicity you can plot the minimum and
for hands-off operation maximum peak values and average over
• Power Measurements and Harmonics time – up to 22 days (Fluke 190 Series) or
measurement (Fluke 125) 16 days (Fluke 120 Series).
• Shielded test leads for oscilloscope,
resistance and continuity Bus Health mode (Fluke 125)
Fluke 124
measurements Bus Health mode gives a clear “Good/
• Up to 7 hours battery operation Bad” indication for the electrical signals
ed on industrial buses and networks, such
• Optically isolated interface for PC and -bus, RS-232 and many
Printer connection (optional) more. The Fluke 125 validates the quality
• Rugged, compact case of the electrical signals as soon as any
electrical signals are passed along the
Connect-and-View™ triggering for network.
Fluke 123 an instant, stable display
cult triggering
can be. Wrong settings show unstable
and sometimes wrong results. Fluke’s
unique Connect-and-View recognizes
signal patterns, and automatically
True RMS sets up correct triggering. It provides a

Included Accessories
PM 8907 line adapter/charger, STL120 shielded
test leads set (1 red, 1 grey), AC120 Alligator
Clips, BB120 shielded BNC adapter, BP120MH
NiMH battery pack, VPS40 wide bandwidth
Voltage Probe (Fluke 124/125), TL75 hard
point test lead, i400s current clamp (Fluke
125), Getting Started booklet, user’s manual
(cd-rom)

Ordering Information
Fluke 123 Industrial ScopeMeter ®
(20MHz)
Fluke 123/S Industrial ScopeMeter ®
(20MHz)
Connect-and-View captures even the most Bus Health mode allows for an analysis of the
+ SCC120 kit complex motor drive signals. signal quality on an industrial network.
Fluke 124 Industrial ScopeMeter ®
(40MHz)
Fluke 124/S Industrial ScopeMeter ®
(40MHz)
+ SCC120 kit
Fluke 125 Industrial ScopeMeter (40 MHz) See page 72 for specifications.
Fluke 125/S Industrial ScopeMeter (40 MHz) +
SCC120 kit Recommended Accessories
SCC120 FlukeView ® Software + OC4USB
Cable + Carrying Case
OC4USB USB Interface Cable
PM9080 RS-232 Interface Cable
DP120 Differential Voltage Probe
ITP120 Isolated Trigger Probe SCC120 C125 DP120 OC4USB SCC128
SW90W FlukeView Software
BHT190 Set of 3 break-out adapters
(Fluke 125)
ScopeMeter® 190C Series
(incl. 225C and 215C)

Speed, performance and analysis power

For more demanding applications, the


ScopeMeter 190C Series high performance
oscilloscopes offer specifications usually
found on top-end bench instruments.
With up to 200 MHz bandwidth, 2.5 GS/s
real-time sampling and a deep memory of
27500 points per input they’re ideal for
engineers who need the full capabilities
of a high performance oscilloscope in a
handheld, battery powered instrument.

• Dual input – 60, 100 or 200 MHz models Bus Health Test (225C and 215C)
• Up to 2.5 GS/s real time sampling per input Bus Health Test analyses the electrical
• Bus Health Test capability for industrial signals on an industrial bus or network
buses, including Profi, Foundation, ModBus and gives a clear “Good”, “Weak” or “Bad”
and many more (225C and 215C) validation mark for each of the relevant
• High resolution color display parameters, presented next to the actual
• High waveform resolution of max. 3000 measurement value.
datapoints per channel The Fluke 225C and 215C can make the
• Digital Persistence for analyzing complex signal quality validation as soon as electrical
dynamic waveforms like on an analog signals are passed along the network,
scope without looking at the data content. They
Fluke 199C • Fast display update rate (> 100/sec) for find errors like improper cable connections,
seeing dynamic behavior instantaneously bad contacts, incorrect grounding and
• Connect&View™ automatic triggering, missing or superfluous terminators.
a full range of manual triggering modes
plus external triggering.
• Automatic capture and replay of
100 screens
• 27500 points per input record length using
ScopeRecord mode
• Up to 1000 V independently floating
isolated inputs
• Waveform reference for visual
comparisons and automatic pass/fail
testing of waveforms
• V pwm function for motor drive and
frequency inverter applications.
• Waveform mathematics: Add, Subtract and
Fluke 196C Fluke 192C Multiply
• Frequency Spectrum Analysis using FFT
• X-vs-Y mode (Lissajous display) for study
of signal relationships
• Cursors, zoom and real-time clock
• 30 automatic waveform measurements
• Over 3.5 hours rechargeable Ni-MH battery Automatic capture and replay
pack of 100 screens
• Includes a 5000 count true-RMS Scope users know how frustrating it is to
multimeter and a TrendPlot™ paperless see a one time anomaly flash by, never to be
recorder seen again. Not with the ScopeMeter 190C
Series! Now you can look back in time with
ScopeMeter for medical imaging and a touch of the replay button. In normal use,
video test applications the instrument continuously memorizes
For tests on such systems, an optional the last 100 screens. Each time a new
Fluke 225C Fluke 215C configuration is available. Please check the screen is acquired, the oldest is discarded.
Fluke website for further details. At any moment you can “freeze” the last
100 screens and scroll through picture-
by-picture or replay as a ‘live’ animation.
Cursors can be used for further analysis.
You can even use the advanced trigger
capabilities to capture up to 100 specific
events. Two sets of 100 captured screens
with individual time stamps can be stored
True RMS for later recall or download to a PC.
On all inputs
ScopeMeter® 190C Series
(incl. 225C and 215C)

See dynamic signal Frequency Spectrum Analysis 190C FlukeView ® Software for documenting,
behavior instantaneously All 190C Color ScopeMeters include archiving and analysis
nd Frequency Spectrum Analysis on Fast Fourier FlukeView ® for Windows ® helps you get more
anomalies and to analyze complex dynamic Transformation (FFT) analysis as a standard out of your ScopeMeter by:
signals by showing the waveforms amplitude feature. • Documenting - transfer waveforms,
distribution over time using multiple This makes it possible to identify the screens and measurement data from the
intensity levels and user selectable decay individual frequency components contained ScopeMeter to a PC. Print or import the data
time - it’s as if you’re looking at the display in a signal. The spectrum analysis function is into your report
of an analog, real time oscilloscope! A fast also handy to reveal the effects of vibration, • Archiving - create a library of waveforms
display update rate reveals signal changes signal interference or crosstalk. An automatic with your comments for easy reference and
instantaneously, useful for instance when window function assures optimal windowing, comparison
making adjustments to a system under test. although you may manually select your • Analysis - use cursors, perform spectrum
preferred time window. analysis or export data to other analysis
programs

Pulse width fluctuations are clearly visible using Digital Frequency Spectrum shows an overview of frequencies FlukeView Screen
Persistence contained in a signal.

Included Accessories
BC190 Battery Charger
BHT190 Set of 3 break-out adapters
(225C/215C)
BP190 NiMH Battery Pack
VPS210-G + VPS210-R Voltage Probe
TL75 Hard Point Test Lead Set
user’s manual (CD-Rom), Getting Started
Booklet

Ordering Information
Fluke 192C Color ScopeMeter
(60 MHz, 500 MS/s)
Fluke 196C Color ScopeMeter
(100 MHz, 1 GS/s) Thanks to the deep memory, very small parts of the waveform can be studied in full detail
Fluke 199C Color ScopeMeter using “zoom”.
(200 MHz, 2.5 GS/s)
Fluke 215C Color ScopeMeter with Bus
Health Test (100 MHz, 1 GS/s)
Fluke 225C Color ScopeMeter with Bus See page 72 for specifications.
Health Test
(200 MHz, 2.5 GS/s)
Fluke 192C/S 192C + SCC191 kit option
Fluke 196C/S 196C + SCC191 kit option
Fluke 199C/S 199C + SCC191 kit option
Fluke 215C/S 215C + SCC191 kit option Recommended Accessories
Fluke 225C/S 225C + SCC191 kit option
SCC190 SW90W FlukeView Software,
OC4USB cable, C190 briefcase
style carrying case
SCC191 SW901W FlukeView Software,
OC4USB cable, industrial style
carrying case ScopeMeter SCC191 Scopemeter SCC190 C195 OC4USB SCC198
C190 Briefcase style carrying case
SW90W FlukeView Software
ScopeMeter ® Accessories

ScopeMeter probes

VPS40 V P S 2 10 - R s e r i e s V P S 2 10 - G s e r i e s D P 12 0 PM8918/301

VPS40 VPS210-R VPS210-G VPS212-R VP212-G VPS220-R VPS220-G VPS101 DP120 PM8918/301
D es c r i p ti on V o l t a ge Voltage Probe Set Voltage Probe Set Voltage Probe Set Voltage Probe Differential Low Pass
Probe Set Set Probe Set Filter Probe
Number and color One Black 1 Red 1 Grey 1 Red 1 Grey 1 Red 1 Grey 1 Black Red & Grey One Blue
A tten u a ti on 10: 1 10: 1 10: 1 100: 1 1: 1 200: 1, 20: 1 10: 1
B a n dw i d t h D C - M H z 40 200 M H z 200 M H z 200 M H z 30 M H z 20 4 kHz
L e n gt h (m ) 1. 2 1. 2 m 2. 5 m 1. 2 m 1. 2 m 1. 5 2. 5
E N 61010- 2 C AT I I 1000 V 1000 V 1000 V 1000 V - 1000 V -
E N 61010- 2 C AT I I I 600 V 600 V 600 V 600 V 300 V 600 V 600 V
ScopeMeter 190 Series
ScopeMeter 120 Series 1) 1)

1) Using BB 120

P M 9 0 9 1/ 9 0 9 2 PM9081 PM9082 PM9093

PM 9091 PM 9092 PM 9081 PM 9082 PM 9093


D es c r i p ti on 5 0 Ω B N C c a bl e s e t 50 Ω BNC cable set Dual Banana plug male to Dual Banana jack female to Male BNC to dual
(1Red, 1Grey, 1Black) (1Red, 1Grey, 1Black) female BNC male BNC female BNC
L e n gt h 1. 5 m 0. 5 m
E N 61010- 2 C AT I I I 300 V 300 V 600 V 600 V 600 V
ScopeMeter 190 Series
ScopeMeter 120 Series 1) 1) 1) 1)

1) Using BB 120

RS200 AS 2 0 0 -R OC 4 US B PM9080 PM9090

R S 200 P r o be A c c e s s o r y R e p l a c e m e n t S e t f o r V P S S e r i e s P r o be s Battery Packs


A S 200- R P r o be A c c e s s o r y S e t , R e d f o r V P S S e r i e s P r o be s BP120MH NiMH Battery Pack for 120 Series + 43B
A S 200- G P r o be A c c e s s o r y S e t , G r ey f o r V P S S e r i e s P r o be s BP190 NiMH Battery Pack for 190 + 430 Series
PM 9080 O p t i c a l I n t e r f a c e A d a p t e r C a bl e f o r s e r i a l p o r t
O C 4U S B O p t i c a l I n t e r f a c e A d a p t e r C a bl e f o r U S B Po r t
PM 9090 P r o b e P i n G r a b b e r F l e x i bl e C l i p f o r V P S S e r i e s P r o b e s
PM 9094 M i n i T e s t h o o k S e t f o r P M 8 9 1 8 P r o be s
PA C 9 1 P r i n t e r A d a p t e r C a bl e
Power Quality Tools and Power
Analyzers

We offer an extensive range of power quality test tools for


troubleshooting, predictive maintenance and long-term recording in
industrial and utility applications. For the development and test of
electrical equipment, our high-precision power analyzers enable easy
eld or as a bench unit in test laboratories.
Power quality tools help pinpoint problems fast

S i n gl e p h a s e T h ree ph a s e
B a s i c m e a s u r e m e n ts A p p l i c a ti o n u s e VR1710 345 43B 430 1735 1740 1750 1760
RMS voltage Detailed RMS trending shows how connected loads
RMS Current behave. (not 1743)
Energy studies
Measure V, I, kW, Cos/DPF, kWhr Get detailed power and energy consumption
Measure MIN/MAX and AVG values profiles during energy audits and pinpoint savings
opportunities.
10 day logging
Energy aggregation
Utility meter pulse input
Energy Loss (Eff. kW, Reactive kVAR, Unbalance
kVAR, Distortion kVAR, Neutral kVAR)
Basic harmonics study
THD measurement (V & I) Discover the source of distortion in your installation, so
Harmonics 1 to 25 for V & I that you can filter those loads or move them to separate
circuits.
Tabular values
Neutral current measurement
Crest factor
Advanced harmonics study
Full harmonic spectrum If distorting loads are causing problems in your
Power harmonics installation, you need comprehensive data to intentify
the source and create a solution.
Harmonics 1 to 50 and dc (no DC)
k-factor
%Fundamental and %RMS
Basic Industrial PQ Troubleshooting
Oscilloscope function When troubleshooting in the field, graphical data
Voltage dips and swells enables you to trace the source of the problem at hand.
Phasor diagram
Trend recording
Inrush current
Advanced industrial PQ troubleshooting
Comprehensive logging capability Complex installations often require a deeper dive into
Transient capture measurement data. Multiple loads may be interacting
randomly to cause a single problem.
Flicker
EN50160 analysis
Complex System interaction event capture
(manual threshold setting)
Random/variable system event capture (Adaptive
threshold setting)
Utility PQ benchmarking
Phase sequence components Before you install sensitive loads, make sure you
Interharmonics understand the existing quality of power delivered by
your utility. Comparing benchmarks over time can help
Mains signaling
pinpoint potential areas of concern.
Power Quality Selection Guide

IEC61000-4-30 Class A
Software
PowerLog To make use of the power data you collect, you need
PQLog software that can help analyze your findings and share
them with equipment providers and plant management.
Power Analyze
PQ Analyze
FlukeView Forms

VIDEO
Power Quality in Industrial Applications
Covers the basics of power quality and looks at the tools and inspection techniques
used to troubleshoot common problems.
VR1710 Single-Phase Voltage
Quality Recorder

Easy-to-use solution for detecting and


recording voltage quality problems
The Fluke VR1710 is a single-phase, plug- • Clear graphical summary of data and
in voltage quality recorder that provides quick overview of key power quality
fast and easy recording of voltage trends, parameters
dropouts, harmonics and general power • Get the complete picture with Min, Max,
quality including dips and surges to help Average RMS values (1/4 cycle) with
maintenance and facilities management time stamps
personnel easily pinpoint the root cause • See the detailed with actual transient
of voltage problems. Voltage quality display (> 100 µs) with time stamp
parameters including RMS average, • Comprehensive analysis of Individual
icker, and harmonics up to harmonic and THD values with trends
the 32nd are recorded using a user-
Fluke VR1710 selected average period from
1 second to 20 minutes.

Applications
• Voltage recording – Monitors and • Flicker measurement – Quantify the
records supply voltage; measures RMS affects of switching loads on lighting
average, minimum and maximum systems.
values, and checks whether the socket • Voltage transients – Capture those
outlet is providing voltage within intermittent, momentary events that
tolerance. may be affecting your equipment; the
• Distortion measurement – Measure full waveform is captured with date,
frequency and harmonics; check timestamp, and duration.
whether the distorting loads (UPS
systems, drives, etc.) are affecting your
other equipment.

Fluke VR1710 and included accessories

PowerLog Setup – Simple set up of Actual transient display Statistical analysis of voltage event
internal clock, logging periods, and (> 100 µs) with time stamp– – reduces analysis time by tracking
intervals with default values for Quickly identify issues with included event quantities and magnitudes.
quick results. graphical software.
PowerLog View – Data presentation
showing RMS voltage and harmonic
trends, actual transients, summary
information and statistics in
accordance with EN50160.

Specifications
(Check the Fluke web for detailed specifications)

O p e r a t i n g v o l t a ge 70 V t o 300 V
M i n /M a x /A v g R M S v a l u e R es ol u t i on 0. 125 V
N u m be r o f ev e n t s 175, 000
D i p s /I n t e r r u p t i o n s Y es
Includes PowerLog software T i m e r es ol u ti on 5 ms
V o l t a ge r e s o l u t i o n ) 0. 125 V
O v e r - v o l t a ge s Y es
Fr eq u en cy Y es
H a r m on i c s m ea s u r em en t E N 6 1 0 0 0 - 4 - 7 (u p t o 3 2 n d )
F l i ck er m ea s u r em en t E N 61000- 4- 15
N u m be r o f r e c o r d i n g c h a n n e l s 1 Ph a s e t o N e u t r a l
Included Accessories 2 Phase/Neutral to Ground
R ec or d i n g ti m e 1 d a y t o 3 3 9 d a y s d e p e n d i n g o n a v e r a ge t i m e f r o m 1 s e c o n d t o 2 0 m i n u t e s
Plug-in Fluke VR1710, USB cable, PowerLog T r a n s i en ts Y e s (> 1 0 0 µ s )
software CD, universal power cord adapters. F r e q u e n c y r a n ge 50 H z ± 1 H z a n d 60 H z ± 1 H z
S a f e t y c a t e go r y r a t i n g C AT I I 300 V

Ordering Information
Fluke VR1710 Voltage Quality Recorder Display: LED Weight: 0.8 kg
Size (HxWxD): 23 x 19.75 x 22.2 cm Two years warranty
345
Power Quality Clamp Meter

The ideal troubleshooting tool for modern


electrical loads
The Fluke 345 measures a wide range of • High safety rating: 600V CAT IV / 1000V
electrical parameters for troubleshooting CAT III rated for use at the service
power disturbances in single- and entrance
three-phase electrical loads. With a • ac/dc current measurements: Clamp-
bright color display to see waveforms on measurement of ac peak and dc
lter to remove current up to 2000 A without breaking
high frequency noise, and a high EMC the circuit
immunity design, the Fluke 345 is ideal • Harmonic analysis: Analyze, display
for measurements on switching loads and log harmonics up to the 30th
such as variable speed drives, electronic harmonic (40th harmonic for 15 Hz to
lighting and UPS systems. 22 Hz)
• Verify batteries: Direct measurement
of dc ripple (%) for battery and dc
systems

S p e c if ic a t io n s
Fluke 345 (Check the Fluke web for detailed specifications)

Current measurement
DC, DC rm s, AC rm s A l l m ea s u r em en t s D C a n d 15 H z t o 1 k H z .
Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rms
measurement (AC + DC).
M e a s u r i n g r a n ge 0 – 2000 A d c or 1400 A C r m s
H a r m on i c s A l l m e a s u r e m e n t s u p t o 3 0 t h h a r m o n i c (4 0 t h h a r m o n i c f o r 1 5 H z t o 2 2 H z ); F r e q u e n c y
range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A

Voltage measurement
DC, DC rm s, AC rm s A l l m e a s u r e m e n t s D C a n d 1 5 H z t o 1 k H z . M a x i m u m ov e r l o a d 1 , 0 0 0 V r m s . V o l t s r m s i s a
true-rms measurement (AC + DC).
M e a s u r i n g r a n ge 0 – 825 V D C or A C r m s
H a r m on i c s A l l m e a s u r e m e n t s u p t o 3 0 t h h a r m o n i c ; F r e q u e n c y r a n ge F 0 : 1 5 H z t o 2 2 H z a n d 4 5 H z
to 65 Hz; Vacrms > 1V
Watts measurement (single- and three-phase) DC, DC rms, AC rms
M e a s u r i n g r a n ge 0 – 1650 k W D C or 1200 k W a c
VA measurement (single- and three-phase) DC, DC rms, AC rms
View waveforms for equipment M e a s u r i n g r a n ge 0 - 1650 k V A D C or 1200 k V A a c
checking and setup VAR measurement (single- and three-phase)
M e a s u r i n g r a n ge 0 – 1250 k V A R
Power factor (single- and three-phase)
M e a s u r i n g r a n ge 0 . 3 c a p …1 . 0 … 0 . 3 i n d (7 2 . 5 ° c a p …0 ° … 7 2 . 5 ° i n d )
Displacement power factor
M e a s u r i n g r a n ge 0 . 3 c a p … 1 . 0 … 0 . 3 i n d (7 2 . 5 ° c a p . . . 0 ° . . . 7 2 . 5 ° i n d )
Kilowatt Hour (kWHr)
M e a s u r i n g r a n ge 40, 000 k W H r
Scope function
T i m e ba s e 2 . 5 m s , 5 m s , 1 0 m s , 2 5 m s , 5 0 m s /d i v
Current management:
R a n ge s 1 0 A /2 0 A /4 0 A /1 0 0 A ; 2 0 0 A /4 0 0 A /1 0 0 0 A /2 0 0 0 A
Voltage measurement:
R a n ge s 4 V /1 0 V /2 0 V /4 0 V /1 0 0 V ; 2 0 0 V /4 0 0 V /1 0 0 0 V
Inrush current function All measurements dc and 15 Hz to 1 kHz
R a n ge s 40, 400 a n d 2000 A
Log parameters over time Memory Up to 50 screen shots and over 150,000 individual measurement values
to track down intermittent faults
Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6 Display: Color transmissive LCD 320 x 240 pixels
x 6 Battery (70 mm diagonal) with 2 level backlight
Battery life (typical): >10 hours (backlight on full); Digital output: USB interface to a PC
>12 hours (backlight reduced) Size (HxWxD): 300 mm x 98 mm x 52 mm
Safety: IEC 61010-1 600 V CAT IV, 1000V CAT III Jaw opening: 60 mm
(maximum input phase-phase 825V rms) double or Jaw capacity: 58 mm diameter
reinforced insulation, pollution degree 2 Weight (including batteries): 0.82 kg
Protection: IP40; EN60529 Two Year Warranty
Operating temperature: 0 °C to 50 °C

Included Accessories
Soft carrying case, Power Log software,
Test probes, Test leads, Alligator clips,
International ac adapter / battery eliminator,
Printed English User manual, Multi-language Recommended Accessories
manual on CD

Ordering Information
Fluke 345 Power Quality Clamp Meter

TLK291 TP220 AC220 TP1 C550


43B Single-phase Power
Quality Analyzer

The perfect tool for tracking down


single-phase power-related problems
The Fluke 43B is the choice for capabilities of a power quality analyzer, a
diagnosing and troubleshooting power 20 MHz oscilloscope, a multimeter and a
quality and general equipment failures. data recorder in a single instrument.
Ease to use thanks to menu selection of
the power modes, it combines the

• Voltage, current, and • Continuously measure


power harmonics volts and amps on a
• Up to 51st harmonic cycle-by-cycle basis for up
• Total harmonic distortion to 16 days
(THD) • Use cursors to read time
• Phase angle of individual and date of sags and
harmonics swells

• Watts, power factor, • Connect-and-View™


COS , VA and VAR scope for quick waveform
• Voltage and current display
waveforms • View voltage and current
channels simultaneously
Fluke 43B

Specifications
(Check the Fluke web for detailed specifications)

M e n u i te m s M e a s u r e m e n ts R a n ge s A c c u r a cy
Volts/Amps/Hz Volts 5.000 V - 1250 V ±(1%+10)
Amps 50.00A - 50.00 kA ±(1%+10)
Mains frequency 40.0 - 70.0 Hz ±(0.5%+2)
On all inputs CF Crest Factor 1,0 à 10,0 ±(5%+1)
Po w e r W a tts , VA R , VA 250 W - 1.56 GW ±(4%+4)
PF, DPF, COS 0.25 W-0.9 ±0.04
0.90-1.00 ±0.03
Harmonics Volts 1 st to 51 st harmonic ±(3%+2) to ±(15%+5)
Amps 1 st to 51 st ±(3%+8) to ±(15%+5)
True RMS Watts 1 st to 51 st ±(5%+2) to ±(30%+5)
K-factor 1.0 to 30.0 ±10%
Sags & Swells Voltage and Current 4 min-16 days selectable ±(2%+10)
Transient Capture 40 ns pulse width Select 20/50/100/200% ± 5% of full scale
Up to 40 transients above or below line voltage
I n r u s h C u r r en t 1 s e c . t o 5 m i n s e l e c t a bl e 1 A t o 1000 A ± 5% of f u l l s c a l e
Ohms/Continuity/ Ohms 500.0 Ω to 30.00 MΩ ± (0.6%+5)
Capacitance Capacitance 50.00 nF to 500.0 µF ± (2%+10)
Temperature ºC -100.0ºC to 400.0ºC ± (0.5%+5)
(with accessory) ºF -200.0ºF to 800.0ºF
S c op e D C , A C , A C +D C , p e a k , Sampling rate: 25 MS/sec
peak-peak, Hz, duty cycle, Bandwidth:
phase, pulse width, Voltage BW (Channel 1) 20 MHz
crest factor Current BW (Channel 2) 15 kHz
Included Accessories S cr een s av es A l l f u n c ti on s 20 s c r een s
TL224 test lead set, AC220 alligator clip set, Recording V/A/Hz, Power, Harmonics,
Ω/Cap, Temperature, Scope
4 min - 16 days selectable Select any two parameters
display mode in each
TP4 test probe set, BP120MH rechargeable
battery pack, BB120 shielded BNC adapter,
PM8907 line adapter/charger, i400s AC current
clamp, AB200 alligator clip set,
Battery life: Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous)
TP1 test probe set, C120 hand carrying case,
Shock & Vibration: Mil 28800E, Type 3, Class III, Style B.
OC4USB interface cable, SW43W FlukeView Operating temperature: 0°C to 50°C; Case: IP51 (dust, drip, waterproof)
software, VPS 40 voltage probe, Fluke 61 IR Size (HxWxD): 232 mm x 115 mm x 50 mm; Weight: 1.1 kg
thermometer, user and application manual. Three Years Warranty

Ordening information
Fluke 43B Power Quality Analyzer Recommended Accessories
(single-phase)

i2000flex i1000s 80TK PAC91


430 Series Three-phase
Power Quality Analyzers

Pinpoint power quality problems faster, safer and


in greater detail
The Fluke 435 and 434 three-phase power AutoTrend - Quickly see the trend
quality analyzers help you locate, predict, Unique AutoTrend gives you fast insight into
prevent and troubleshoot problems in changes over time. Every displayed reading
power distribution systems. These easy-to- is automatically and continuously recorded
use handheld tools have many innovative without having to set up threshold levels
features to give you the details to pinpoint or interval times, or having to manually
problems faster and safer. start the process. You can quickly view
trends in voltage, current, frequency, power,
• Complete three-phase troubleshooting icker on all three phases plus
tool: measures virtually every power neutral. And you can analyze the trends
system parameter: voltage, current, using the cursors and zoom function – even
frequency, power, power consumption while background recording continues.
icker, harmonics
and inter-harmonics. Captures events like SystemMonitor - Check performance
dips and swells, transients, interruptions against EN50160 with ease
and rapid voltage changes. With a single push of a button, the unique
• The Fluke 435 features 0.1 percent voltage System-Monitor gives you an overview of
Fluke 435
accuracy making it fully compliant with power system performance, and checks the
the IEC 61000-4-30 Class A standard compliance of incoming power to EN50160
• Logger: record the detail you need. cations.
gurable long-time The overview is shown on a single screen,
recording gives you the MIN, MAX and AVG with color-coded bars clearly indicating
readings of up to 100 parameters on all which parameters fall outside the limits.
4 phases with selectable averaging time
down to 0.5 seconds. Enough memory is
available to record 400 parameters with 1
minute resolution for up to a month.
• Four channels: simultaneously measures
voltage and current on all three phases
and neutral.
• AutoScaling: easier trend analysis with
automatic scaling of the vertical axis you
will always use the full display to view the
waveforms.
• Automatic transient display: captures up to
40 dips, swells, interruptions or transients
automatically.
Fluke 434 • Meets the stringent 600 V CAT IV,
1000 V CAT III safety standard required for
measurements at the service entrance.
True RMS • Rugged, handheld instrument operates
for more than 7 hours on included
On all inputs
rechargeable NiMH battery pack. Menu-
es operation.
• Extensive data analysis possibilities.
Cursors and zoom can be used ‘live’ while
ine’ on
stored measurement data. The stored
measurements can also be transferred to a
PC with FlukeView software (included with
Fluke 435 and 434).
• The Fluke 435 comes with Power Log
software to analyse recorded data and to
create reports.
• Complete package includes everything to
ex clamps
with Fluke 435, 5 voltage test leads and
clips, line adapter/battery charger and hard
case.
• Complies with IEC 61000-4-30
measurement standards.
The System-Monitor overview screen gives instant insight
into whether the voltage, harmonics, flicker, frequency and
the number of dips and swells fall outside the set limits.
A detailed list is given of all events falling outside the set
limits.

AutoTrend automatically records all displayed parameters


in the background.
430 Series Three-phase
Power Quality Analyzers

Logging function allows you to customize measurement Measure and record power (W), VA and VARs. Track harmonics up to the 50th, and measure and record
selections and provides instantaneous analysis of user- The 434 and 435 add the ability to record energy THD in accordance with IEC61000-4-7 requirements
selectable parameters. consumption.

Specifi cations
(Check the Fluke web for detailed specifications)

Inputs Number of inputs 4 voltage and current (3 phases + neutral)


Maximum input voltage 1000 Vrms (6kV Peak)
Maximum sampling speed 200 kS/s on each channel simultaneously

Volt/Amps/Hertz V r m s ( A C +D C ) 1 …1 0 0 0 V ± 0 . 1 % o f n o m i n a l v o l t a ge
V pk 1 …1 4 0 0 V 5% of V n om
C r e s t f a c t o r , v o l t a ge 1. 0 . . . > 2. 8 ± 5%
A r m s ( A C +D C ) 0 …2 0 , 0 0 0 A ± 0. 5% ± 5 c ou n t s
A pea k 0 - 5500 A 5%
C r es t f a c t or, A 1 … 10 ± 5%
Fluke 435 with flex clamps Hz 50Hz nominal 42.50 ... 57.50 Hz ± 0.01Hz
Dips and swells Vrms (AC+DC) 2 0.0% ….100% of Vnom ± 0.2% of nominal voltage
Arms (AC+DC) 2 0 … 20,000 A 1 ± 1% ± 5 c ou n t s
Harmonics Harmonic (interharmonic) (n) DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
V rm s 0. 0 … 1000 V ± 0 . 0 5 % o f n o m i n a l v o l t a ge
A rm s 0. 0 … 4000 m V x c l a m p s c a l i n g ± 5% ± 5 c ou n t s
Included Accessories W a tts d ep en d s c l a m p s c a l i n g a n d ± 5% ± n x 2% or reading,
Fluke 435/434: Hard carrying case C430 (434)/ voltage ± 10 counts
D C v o l t a ge 0. 0 … 1000 V ± 0 . 2 % o f n o m i n a l v o l t a ge
Water-tight hard case with rollers C435 (435) T HD 0. 0 … 100. 0 % ± 2 . 5 % V a n d A (± 5 % W a t t )
4 current clamps, i400s, CAT IV 600 V Hz 0 … 3500 H z ± 1 Hz
(Fluke 434) P h a s e a n gl e - 3 6 0 º . . . +3 6 0 º ± n x 1. 5º
Power and Energy W a tt, VA , VA R 1. 0 … 20. 00 M V A 1 ± 1% ± counts
4 current clamps, i430-Flex-4pk, CAT IV kWh, kVAh, kVARh 00.00 …200.0 GVAh 1
± 1.5% ± 10 counts
600 V (Fluke 435) Power Factor/ Cos / D PF 0 …1 ± 0. 03
5 Test leads, 4 black, 1 green Flicker P s t (1 m i n ), P s t , P l t , P F 5 0. 00 … 20. 00 ±5 %
Unbalance V ol ts 0. 0 … 5. 0% ± 0. 5%
Battery Charger Eliminator, BC430 C u r r en t 0. 0 … 20% ± 1%
FlukeView Software, SW43W Transient capture V ol ts ± 6000 V ± 2. 5% of V r m s
Power Log Software (435) Minimum detect duration 5 µs (200 kS/s sampling)
Optical Cable for USB, OC4USB Inrush mode A r m s ( A C +D C ) 0. 000 … 20. 00 k A ± 1% of meas ± 5 counts
1

I n r u s h d u r a t i o n ( s e l e c t a bl e ) 7. 5 s … 30 m i n ± 2 0 m s (F n o m = 5 0 H z )
Color localization set, WC100 AutoTrend recording S a m pli n g 5 r e a d i n gs /s e c c o n t i n o u s s a m p l i n g p e r c h a n n e l
Getting Started printed M em or y 1800 m i n , m a x a n d a v g p oi n t s f or ea ch r ea d i n g
User Manual (CD-ROM) R ec or d i n g ti m e U p t o 450 d a y s
Z oom U p t o 12x h or i z on t a l z oom
Basic versions: Excl. current clamps Memory S cr een s & da ta 5 0 , s h a r e d m e m o r y d i v i d e d be t w e e n l o ggi n g, s c r e e n s a n d d a t a s e t s
Standards Measurement methods used IEC61000-4-30 class A; EN50160; IEC 61000-4-15; IEC 61000-4-7

Ordering information
Fluke 435/Basic Power Quality Analyzer 1
depending clamp scaling
(three phase) 2
Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

Fluke 435 Power Quality Analyzer


(three phase) Battery life: > 7 hours with rechargeable NiMH (installed); Battery charging time: 4 hours typical
Safety: EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV
Fluke 434/Basic Power Quality Analyzer Case: Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
(three phase) Shock: 30 g; Vibration: 3g according to MIL-PRF-28800F Class 2
Fluke 434 Power Quality Analyzer Operating temperature: 0°C to +50°C
Size (HxWxD): 256 mm x 169 mm x 64 mm; Weight: 1.1 kg
(three phase) Three Years Warranty
Fluke 434/LOG Logger Upgrade Kit: Adds
the Logger Function of
the 435 to the 434 Recommended Accessories
OC4USB Serial Interface Adapter/
Cable (USB)
PM9080 Serial Interface Adapter/
Cable (RS232)
GPS430 GPS sync module
for 430 Series GPS430 i430-flex-4pk i5sPQ3 i1000s OC4USB
1735 Power Logger
Performs electrical load studies, energy
consumption testing, and general power
quality logging
The Fluke 1735 Power Logger is the ideal • Record power and associated
tool for electricians and maintenance parameters for up to 45 days
technicians for conducting energy • Monitor maximum power demand over
studies and basic power quality logging. ned averaging periods
The 1735 is easy to set up with its color ciency
exible current improvements with energy
probes. consumption tests
The 1735 logs most electrical power • Measure harmonic distortion caused by
parameters, harmonics and captures electronic loads
Fluke 1735
voltage events. View graphs and generate • Improve reliability by capturing voltage
reports with the included Fluke Power dips and swells from load switching
Log software. rm instrument setup easily with
color display of waveforms and trends

View recorded data in simple graphs and Conduct load studies


tables with Fluke Power Log software. for up to 45 days and
view saved data Access voltage and
on-screen or on a current harmonics
computer. up to the 50th.

Quantify energy
consumption quickly
on-screen or log to Capture voltage events
memory for extended using user-defined
periods. thresholds.

Customize the report generator to easily


generate professional looking reports. Specifications
(Check the Fluke web for detailed specifications)

V ol ts r m s V - r m s w y e m e a s u r e m e n t r a n ge s :
57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/
400 V/417 V/480 V AC
V-rms delta measurement ranges:
100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/
690 V/720 V/830 V AC
A m ps r m s F l e x i s e t m e a s u r e m e n t r a n ge : 1 5 A / 1 5 0 A / 3 0 0 0 A r m s ( a t s i n e )
Current clamp measurement range: 1 A/10 A
Fr eq u en cy M e a s u r e m e n t r a n ge : 4 6 H z t o 5 4 H z a n d 5 6 H z t o 6 4 H z
H a r m on i c s a n d T H D T o 5 0 t h h a r m o n i c (< 5 0 % o f n o m )
Power measurement Measuring range: see V-rms and A-rms measurement ranges
(P - Active, S - Apparent, Q - Reactive, D - Distorting)
Energy Measurement (kWh, KVAh, kVARh) Measuring range: see V-rms and A-rms measurement rangeso
P F ( Po w e r f a c t o r ) 0. 000 t o 1. 000
E v en ts D e t e c t i o n o f v o l t a ge d i p s , v o l t a ge s w e l l s a n d v o l t a ge i n t e r r u p t i o n s w i t h a
10 ms resolution and measuring error of the half period sine wave of rms.

General
M em or y 4 M B F l a s h m e m o r y, 3 . 5 M B f o r m e a s u r i n g d a t a
S a m pl e r a te 10. 24 k H z
L i n e f r eq u en cy 5 0 H z o r 6 0 H z , u s e r - s e l e c t a bl e , w i t h a u t o m a t i c s y n c h r o n i z a t i o n

Display: VGA Graphic Color transmissive displays Power supply: NiMH battery-pack, with AC adapter
320 x 240 pixels with additional background lighting (15 V to 20 V/0.8 A)
and adjustable contrast, text and graphics in color Battery Life: Typical > 16 hours without backlight and
Included Accessories Interface: RS-232 SUB-D socket; 115.2 k Baud,
8 data bits, no parity, 1 stop bit, firmware updates are
> 6 hours with backlight high
Operating temperature: 0°C to +40°C
FS17XX 4-phase flexible current clamp set, possible with the RS-232 interface (9-pole extension Size (HxWxD): 240 mm x 180 mm x 110 mm
VL1735/1745 voltage lead set, Power Log cable) Weight: 1.7 kg, including battery
Housing: IP65; EN60529 (refers only to the main Two Year Warranty
software, color localization set, PC interface housing without the battery compartment)
cable, international ac adapter, BC1735 battery
charger, soft carrying case, printed English
manual and multi-language manual on CD.

Ordering Information
Fluke 1735 Power Logger
1740 Series Three-Phase
Power Quality Loggers Memobox

Assess power quality and conduct long-term


studies with ease
Compact, rugged and reliable, the Fluke • Plug and play: Set up in minutes with
1740 Series three-phase power quality automatic current probe detection and
loggers are everyday instruments for powering
technicians who troubleshoot and • Installs inside the cabinet: Compact,
analyze power distribution systems. fully-insulated housing and accessories
Capable of simultaneously logging up t easily in tight spaces next to live
to 500 parameters for up to 85 days and power
capturing events, the Fluke 1740 Series • Monitors power for the long-term:
helps uncover intermittent and hard-to- Data can be downloaded during
nd power quality issues. There are three recording without interruption
models to choose from to meet your • Measure voltage with premium
basic or advanced power logging needs. accuracy: IEC61000-4-30 Class-A
Fluke 1743 compliant voltage accuracy (0.1%)
Fluke 1743: IP65 waterproof monitor • Quickly validate quality of power:
Fluke 1744
for logging the most common power Assess power quality according to
parameters including V, A, W, VA, VAR, PF, EN50160 power quality standard with
icker, voltage events and THD. statistical overview

Fluke 1744: Includes the same features


as the Fluke 1743. In addition to common
power parameters, the Fluke 1744 also
measures voltage and current harmonics,
interharmonics, mains signaling,
unbalance, and frequency.
Fluke 1745

Fluke 1745: Advanced IP50 power quality


logger with the same measurement
capability as the 1744, plus real-time LCD,
ve hour UPS.

The included PQ Log software helps you


Specifi cations
to quickly identify the root cause of a (Check the Fluke web for detailed specifications)
disturbance.
1745 1744 1743
Measurement of common power parameters: V, A, W,
VA, VAR, PF, energy, flicker, voltage events (dips, swells,
Included Accessories interruptions), and THD
Fluke 1743/1744/1745: exible current Measurement of voltage and current harmonics to the
50th, unbalance, frequency and mains signaling
clamp set , VL1735/1745 voltage lead set (1745 Dust/water resistance I P 50 I P 65 w a t er p r oof
only), Power Log software, RS232 interface Display LED + LCD LED LED
cable and RS232-USB adapter, 4 black dolphin Memory 8 MB 8 MB 8 MB
clips, WC17XX color localization set, carrying UPS ride-through > 5 hrs 3s 3s
cate with measurement values, EN 50160
printed English manual and multi-language
manual on CD.
Basic models: Excl. current clamps FS17XX

Ordering Information Power supply: 88 V … 660 V AC


Safety: IEC/EN 61010-1 600 V CAT III, 300 V
Size: Fluke 1745: 282 mm x 216 mm x 74 mm;
Fluke 1743/44: 170 mm x 125 mm x 55 mm
Fluke 1743 Basic Power Quality Logger CAT IV, pollution degree 2, double insulation Weight: Fluke 1745 – approx. 3 kg;
Memobox Housing: Fully insulated housing and accessories Fluke 1743/44: approx. 2 kg
Operating temperature: 0 °C to 35°C Two Year Warranty
Fluke 1743 Power Quality Logger Interface: RS 232, 9600 ... 115 000 Baud, automatic
Memobox Baud rate selection, 3-wire communication
Fluke 1744 Basic Power Quality Logger
Memobox
Fluke 1744 Power Quality Logger
Memobox
Fluke 1745 Power Quality Logger
Memobox
1750 Three-Phase Power
Recorder

New Never miss capturing a disturbance

With its exclusive threshold-free • Captures everything: Cross-channel


measurement system, the Fluke 1750 and current triggering capture every
Power Recorder measurement, on every channel, every
captures every measurement, every event, time.
on every cycle, all the time. Outstanding • Intuitive PC software: Easily analyze
accuracy and resolution provide complete data and generate reports. Automated
visibility into your installation or EN50160 reporting and compliance.
On all inputs distribution system. • Plug and play: Set up in minutes with
dentifying current probes and
• Power quality that meets the standard: single-lead voltage connections.
All measurements comply with • No need to reconnect wires: Swap
IEC61000-4-30 standards for correct channels internally with the wireless
evaluation of all measured values PDA or PC when connections are not
including voltage, current, power, correct.
icker etc. • Measure every parameter: Voltage and
• guration: PDA current on three phases, neutral, and
wireless “front panel interface” provides ground.
the ability to verify setup without a • 5 MHz, 8000 Vpk waveform capture:
laptop along with a window into what Get a detailed picture of even the
the instrument is recording, even in shortest events.
awkward test locations. • Quickly retrieve data: With included SD
• Threshold-free setup: Apply thresholds memory card or via the 100BaseT high-
after data is collected with Fluke Power speed Ethernetv connection
Analyzer Software so there is no need to
worry about missed information due to
incorrect set-up.

View measurements real time with wireless PDA interface

Specifications
(Check the Fluke web for detailed specifications)

Power quality measurement standards


Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160
C l o c k /c a l e n d a r L ea p y ea r s , 24- h ou r c l ock
R ea l - ti m e c l ock a c c u r a cy N o t m o r e t h a n ± 1 s /d a y
I n ter n a l m em or y c a p a c i ty f or d a ta A t l ea s t 1 G B
M a x i m u m r ec or d i n g p er i od A t l ea s t 31 d a y s
M ea s u r em en t ti m e c on tr ol A u tom a ti c
M a x i m u m n u m be r o f ev e n t s L i m i t e d o n l y by t h e s i z e o f t h e i n t e r n a l m e m o r y
Po w e r r e q u i r e m e n t s 100 t o 240 V r m s ± 10 %, 47- 63 H z , 40 W
Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging

Safety: EN 61010-1 2nd Edition; 2000


Weight: 6.3 kg
Size (H x W x D): 215 x 310 x 35 mm
Included Accessories One Year Warranty
PDA and charger power plug adapters, 4 - 400
A current probes (3140R), 5 test leads and
clips, SD memory card., Fluke Power View and R e c o m m e n d e d A c c e s s o r ie s
Fluke Power Analyze software,
power cord with international plug set,
Ethernet cable, color localization set, soft M od el D e s c r i p ti o n
carrying case, Printed Getting Started manual, 3110- PR F l e x i bl e C u r r e n t T r a n s f o r m e r ( 2 A - 1 0 0 A )
CD with software and users manual PDF 3210- PR F l e x i bl e C u r r e n t T r a n s f o r m e r ( 2 0 A – 1 0 0 0 A )
3310- PR F l e x i bl e C u r r e n t T r a n s f o r m e r ( 1 0 0 A - 5 0 0 0 A )
Basic model: excl. 4 current probes (3140R) 3312- PR F l e x i bl e C u r r e n t T r a n s f o r m e r ( 1 0 0 A – 5 0 0 0 A )
3005- PR C l a m p - o n C u r r e n t T r a n s f o r m e r (0 . 0 1 A – 5 A )
3014- PR C l a m p - o n C u r r e n t T r a n s f o r m e r (0 . 1 A – 4 0 A )
Ordering Information 3140R C l a m p - o n C u r r e n t T r a n s f o r m e r (2 A – 4 0 0 A )
F L U K E - 1 7 5 0 /S E A T - L F l u k e Po w e r A n a l y z e – A d d i t i o n a l S E A T L I C E N S E
Fluke 1750/B Three-Phase Basic Power F L U K E - 1 7 5 0 /S I T E - L F l u k e Po w e r A n a l y z e – A d d i t i o n a l S I T E L I C E N S E
Recorder F L U K E - 1 7 5 0 /C A S E H ard C as e
Fluke 1750 Three-Phase Power C S 1750 S of t C a s e
Recorder H P I PA Q 2 4 9 0 A d d i t i on a l W i r e l e s s I n t e r f a c e PDA
F L U K E - 1 7 5 0 /M C A d d i t i on a l 512 M B S D M em or y C a r d
1760 Three-Phase Power
Quality Recorder Topas

Class-A compliance for the most demanding


power quality tests
The Fluke 1760 Three-Phase Power • GPS time synchronization: Correlate
Quality Recorder is fully compliant to data with events or datasets from other
IEC 61000-4-30 Class-A, for advanced instruments with precision
power quality analysis and consistent • Uninterrupted power supply
compliance testing. Designed for analysis (40 minutes): Never miss important
of utility and industrial power distribution events - even record the beginning and
systems, in medium and low-voltage end of interruptions and outages
networks, the Fluke 1760 provides the • 10 MHz, 6000 Vpk waveform capture:
exibility to customize thresholds, Get a detailed picture of even the
algorithms, and measurement selections. shortest event
Fluke 1760 It has 8 input channels (4 currents/4 • 2 GB data memory: Enables detailed,
voltages or 8 voltages), and captures the simultaneous recording of numerous
most comprehensive details on user power parameters for long periods of
selectable parameters. time
• Includes Comprehensive software:
Provides trend diagrams for root cause
analysis, statistical summaries, report
writing and real-time data monitoring
in the online mode

Features
(Check the Fluke web for detailed specifications)

1760 Basic 1760TR Basic 1760 1760TR


Power quality statistics according to EN50160
Voltage event list (dips, swells and interruptions)
Continuous recording of:
Voltage
Current
Power P, Q, S
Power factor
kWh
Flicker
Unbalance
Frequency
Voltage and current harmonics to the 50th/
Interharmonics
THD
Mains signaling
Triggered recordings
Online mode (Oscilloscope, transients and events)
Fast transient analysis up to 10 MHz
4 voltage probes
4 dual-range flexible current probes (1000 A / 200 A ac)
GPS time sync receiver
Memory 2 GB Flash memory
The included PQ Analyze software
provides a detailed overview of several
power quality parameters on one
dashboard according to the EN50160
power quality standard.
Power supply: 83 V to 264 V, 45 to 65 Hz Operating temperature: 0 °C to 35°C
Battery pack: NIMH, 7.2 V, 2.7 Ah (up to 40 minutes Interfaces: Ethernet (100 MB/s), RS-232, external
back-up power supply) modem via RS-232
Safety: 600V CAT IV/1000V CAT III Size (HxWxD): 325 mm x 300 mm x 65 mm
(Rated for use at the service entrance) Weight: Approxiamtely 4.9 kg
Included Accessories Housing: Fully insulated robust plastic housing Two Year Warranty
4 x TPS Flex 24 flexible current probe, 4 x
TPS VoltProbe 6000V, 2 GB internal flash
memory, ST1760 standard Ethernet cable,
RS232 interface cable and RS232-USB adapter, R e c o m m e n d e d A c c e s s o r ie s
CS1760 crossover Ethernet cable, 1 mains (Check the Fluke web for complete accessory list)
cable, PC software on CD-ROM, WC17xx color
localization set, GPS-time sync (1760TR only) M od el D e s c r i p ti o n
CS 1750/1760 carrying bag, hardware and • T P S V O LT P R O B E 1 0 V 1 0 V V o l t a ge P r o b e s ( R a n ge : 0 . 1 V t o 1 7 V )
• T P S V O LT P R O B E 1 0 0 V 1 0 0 V V o l t a ge P r o b e s ( R a n ge : 1 V t o 1 7 0 V )
software manual • T P S V O LT P R O B E 4 0 0 V 4 0 0 V V o l t a ge P r o b e s ( R a n ge : 4 V t o 6 8 0 V )
Basic models: Excl. current clamps TPS flex 24 • T P S V O LT P R O B E 6 0 0 V 6 0 0 V V o l t a ge P r o b e s ( R a n ge : 1 0 V t o 1 0 0 0 V )
• T P S V O LT P R O B E 1 K V 1 0 0 0 V V o l t a ge P r o b e s ( R a n ge : 1 0 V t o 1 7 0 0 V )
Ordering Information • T PS F L E X 18 F l e x i b l e C u r r e n t P r o b e ( R a n ge : 1 A t o 1 0 0 A / 5 A t o 5 0 0 A )
• T PS F L E X 24 F l e x i b l e C u r r e n t P r o b e ( R a n ge : 2 A t o 2 0 0 A / 1 0 A t o 1 0 0 0 A )
Fluke 1760 Basic Power Quality Recorder • T PS F L E X 36 F l e x i b l e C u r r e n t P r o b e ( R a n ge : 3 0 A t o 3 0 0 0 A / 6 0 A t o 6 0 0 0 A )
Topas • T PS C L A M P 10 A / 1 A C l i p - o n C u r r e n t T r a n s f o r m e r ( R a n ge : 0 . 0 1 A t o 1 A / 0 . 1 A t o 1 0 A )
Fluke 1760TR Basic Power Quality Recorder • T PS C L A M P 50 A / 5A C l i p - o n C u r r e n t T r a n s f o r m e r ( R a n ge : 0 . 0 5 A t o 5 A / 0 . 5 A t o 5 0 A )
Topas • T PS C L A M P 200 A / 20 A C l i p - o n C u r r e n t T r a n s f o r m e r ( R a n ge : 0 . 2 A t o 2 0 A / 2 A t o 2 0 0 A )
• T PS S H U N T 20 M A 2 0 m A a c / d c S h u n t ( R a n ge : 0 t o 5 5 m A )
Fluke 1760 Power Quality Recorder • T PS S H U N T 5 A 5 A a c / d c S h u n t ( R a n ge : 0 t o 1 0 A )
Topas
Fluke 1760TR Power Quality Recorder
Topas
Fluke model number i1A/10A i1A/10A i5A/50A i5A/50A i20A/200A i20A/200A FS17xx FS17xx IP65 i3000 flex ... 4PK i400s i430 ... flex ... 4PK i5sPQ3
CLAMP PQ3 CLAMP PQ4 CLAMP PQ3 CLAMP PQ4 CLAMP PQ3 CLAMP PQ4

D es c r i p t i on 3 ... ph a s e 4 ... phase 3 ... phase 4 ... phase 3 ... phase 4 ... phase 4 Phase flexiset, 4 Phase flexiset, 4 ... phase Single phase 4 ... phase 3 ... phase 5A
1A/10A Mini 1A/10A Mini 5A/50A Mini 5A/50A Mini 20A/200A 20A/2000A IP41 IP65 3000A Flexible 400A current 3000A Current clamp
current clamp current clamp current clamp current clamp Mini current Mini current current clamp clamp Flexible set
set set set set clamp set clamp set set (4 required) current clamp
set
O l d F l u k e m od el # CU R R EN T MBX CLAMP MBX CLAMP MBX CLAMP MBX CLAMP MBX CLAMP MBX Lem Flex MBX Lem Flex
CLMAPS 1A 1A/10A+N 5A/50A 5A/50A+N 20A/200A 20/2000A+N (15/150/3000) (15/150/3000)
(EPO450A) (EPO451A) (EPO452A) (EPO453A) (EPO455A) (EPO456A) (EP0404A) (EP0404A)

Fluke 1735
Fluke 174X
Fluke 43X
Nominal current range(s) 1A 1A 5A 5A 20 A 20 A 15A 150A 1500A 15A 150A 1500A 30 A 40 A 3000 A 5A
10 A AC 10 A AC 50 A AC 50 A AC 200 A AC 200 A AC 3000A AC 3000A AC 300 A 400 A
3000 A
Cont. AC current range 10 mA ... 1 A 10 mA ... 1 A 50 mA ... 5 A 50 mA ... 5A 200 mA ... 200 mA ... 450mA … 15A 450mA … 15A 1 A ... 30 A 0.5 A ... 40 A 30 A ... 3000 A 0.01 A ... 6 A
100 mA ... 10 A 100 mA ... 500 mA ... 500 mA ... 20 A 20 A 600mA… 150A 600mA… 150A 1 A ... 300 A 5 A ... 400 A
10 A 50 A 50 A 2 A ... 200 A 2 A ... 200 A 6A… 1500A 6A… 1500A 1 A ... 2400 A
12A… 3000A 12A… 3000A

H i gh e s t c u r r e n t 20 A 20 A 100 A 100 A 300 A 300 A 3300 A 3300 A 4000 A 1000 A 100 k A 70 A


Lowest measurable current 10 mA 10 mA 50 mA 50 mA 200 mA 200 mA 450 mA 450 mA 1A 0.5 A 30 A 10 mA
1)
Basic accuracy (48 ... 65 Hz) 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2%+2% position 2%+2% position 2% + 2 A 2% + 0.15 A 1% 1%
influence influence
Usable frequency 40 Hz ... 10 kHz 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40 Hz ... 10 40Hz …5kHz 40Hz …5kHz 10 Hz ... 100 45 Hz ... 3 kHz 10 Hz ... 7 kHz 40 Hz ... 5 kHz
kHz kHz kHz kHz kHz kHz
Requires battery
Flex head length 61 c m 61 c m C lam p 61 cm Clamp
opening: opening:
32 mm 15 mm
O u t p u t l ev e l (s ) 7 5 m V /A 7 5 m V /A 1 5 m V /A 1 5 m V /A 3 . 7 5 m V /A 3 . 7 5 m V /A 0 . 1 m V /A 0 . 1 m V /A 1 0 m V /A 10 mV/A 0.085 mV/A 400 mV/A
1 mV/A 1 mV/A @50 Hz
0.1 mV/A
O u t p u t c a bl e ( m ) 2 2 2 2 2 2 2 2 2.1 2.5 2.5 2.5
S a f ety r a ti n g C AT I I I 600 V C AT I I I 600 V C AT I I I 600 V C AT I I I 600 V C AT I I I 600 V C AT I I I 600 V C AT I I I 1000 V CAT III 1000 V CAT III 600 V CAT III 1000 V CAT III 1000 V CAT III 600 V
CAT IV 600V CAT IV 600V CAT IV 600 V CAT IV 600 V

C on n ec ti on O n e c on n ec tor O n e c on n ec tor O n e c on n ec tor O n e c on n ec tor O n e c on n ec tor O n e c on n ec tor O n e c on n ec tor O n e c on n ec tor 4 x BN C 4 x BN C 4 x BNC 3 x BNC

BNC to banana adapters included n/a n/a n/a n/a n/a n/a n/a n/a

1
Basic accuracy: % reading plus floorspec.
n/a = not applicable
Power Quality Current Clamps

i3000 flex-4PK i4 0 0 s i4 3 0 - f le x - 4 P K i5 s P Q 3
(4x i3000s flex24)
Norma 4000/5000
Power Analyzers

Reliable, highly accurate measurements for


the test & development of power electronics
The compact Fluke Norma Series The Series consists of the Fluke Norma
Power Analyzers provide the latest 4000 Three-Phase Power Analyzer and
measurement technology to assist the Fluke Norma 5000 Six-Phase Power
engineers with the development and Analyzer. These rugged analyzers provide
testing of motors, inverters, lighting, unmatched price performance for easy
power supplies, transformers and eld, or as a bench
automotive components. unit in laboratories and on test benches.

Based on a patented, high-bandwidth • Simple user interface ensures easy,


architecture, the instruments deliver intuitive operation
Fluke Norma Series Power Analyzers high-precision measurements of single gurable modular
or three-phase current and voltage, design
harmonics analysis, Fast Fourier • Simultaneous parallel acquisition of all
Transformation (FFT) analysis, as well as phases
calculations of power and other derived • Voltage, current and power harmonics
values. up to the 40th
• Includes FFT analysis, vector diagram
gurable system display, recorder function, and Digital
design with plug-in power phases and Oscilloscope (DSO) mode
other optional modules provides the • User selectable average time – from
exibility to meet a variety of application 15ms to 3600s
measurement requirements. Recorded • Expandable on-board memory for
data and waveforms can be viewed storage of measured values
clearly in the large color display and
easily downloaded to a PC for analysis
and report writing.
Fluke Norma 4000

Fast Fourier Digital Oscilloscop Vector Display Recorder function


Transformation (FFT) (DSO) mode
analysis

S p e c if ic a t io n s
Fluke Norma 5000 (Check the Fluke web for detailed specifications)

F lu k e N or m a 4000 F lu k e N or m a 5000
N u m be r o f P h a s e s 1 or 3 3, 4 or 6
W e i gh t A p p r ox . 5 k g A p p r ox . 7 k g
S i z e (H x W x D ) 15 c m x 23. 7 c m x 31. 5 c m 15 c m x 44. 7 c m x 31. 5 c m
O n - bo a r d P r i n t e r No Y e s (o p t i o n a l )
D i s play C ol or, 5. 7“ / 144 m m - 320 x 240 p i x el
B a n dw i d t h d c t o 3 M H z or d c t o 10M H z d ep en d i n g on i n p u t m od u l e
B a s i c A c c u r a cy 0. 2%, 0. 1% or 0. 03% d ep e n d i n g on i n p u t m od u l e s
S a m pl i n g R a te 0. 33 M H z or 1 M H z d ep en d i n g on i n p u t m od u l es
V o l t a ge I n p u t R a n ge 0. 3 V t o 1000 V
Current Input Range (direct, not via shunt) 0.03 mA – 20 A depending on input module
M e m o r y f o r C o n f i gu r a t i o n s 4 M B , e x p a n d a bl e t o 1 2 8 M B
M e m o r y f o r S e t t i n gs 0. 5 M B
Fa s t F o u r i e r T r a n s f o r m a t i o n (F F T ) T o t h e 40t h h a r m on i c
R S 232 I n t er f a c e S ta n da rd
PI1 Process Interface (8 analog/impulse inputs and Optional
4 analog outputs)
IEEE 488.2 /GPIB Interface (1 MBit/s Ethernet / Optional
10 MBit/s or 100 Mbit/s)
Fluke NormaView PC Software (for data download, Standard
Included Accessories analysis & report writing)
Power Supply Cable, RS232 Interface and USB
adaptor for Data Download, Fluke NormaView
PC Software, User’s Manual, Test Certificate,
and Calibration Values.

Ordering Information Operating temperature: Housing: Solid metal case


+ 5 °C to 35 °C Safety: EN 61010-1 / 2nd Edition, 1000 V CAT II
Fluke Norma 4000 Three-Phase High
Storage temperature: (600 V CAT III)
Precision Power Analyzer - 20 °C to 50 °C Two Year Warranty
Fluke Norma 5000 Six-Phase High Precision Climatic class: KYG DIN 40040, maximum
Power Analyzer 85% relative humidity, non-condensing.
Norma 4000/5000
Power Analyzer Accessories

Power Phases
The Fluke Norma 4000 Power Analyzer Each plug-in power phase consists of
can be equipped with up to three power a voltage and a current measurement
phases and the Fluke Norma 5000 Power channel. Each measuring channel is
Analyzer can be equipped with up to six available for each basic unit.
power phases. Users can select the power
phase best suited for their application.
Fluke Norma 4000 (rear view) cations vary depending on the model
of the power phase.

Power Phase Overview

3024770 3024812 3024820 3024835


C h a n n el PP42 PP50 PP54 PP64
Accuracy 0.2% 0.1% 0.03%
(0.1% rd + 0.1% rg) 0.05% rd + 0.05% rg (0.02% rg + 0.01% rg)
Current range 20 A 10 A 10 A 10 A
Sampling rate 341 kHz 1 MHz 341 kHz 341 kHz
Bandwidth 3 MHz 10 MHz 3 MHz 3 MHz

Fluke Norma 5000 (rear view)

Shunts

The input modules can take up to 10 A


or 20 A directly or measure current via
wideband precision shunts. The available
range of shunts enables measurements up
to 1500 A and can be used in conjunction
Optional shunts for Fluke Norma Series Power
with all of the available input modules.
Analyzers

3024677 32 A Planar Shunt


3024689 Cables for 32 A Planar Shunt
3024886 10 A Triaxial Shunt with Cables
(0.333 ., 0 to 0.5 MHz)
3024899 30 A Triaxial Shunt with Cables
(0.010 ., 0 to 0.5 MHz)
3024847 100 A Shunt with Cables (0.001 Ω, 0 to 0.5 MHz)
3024858 150 A Shunt with Cables (0.5 mΩ, 0 to 0.5 MHz)
3024864 300 A Shunt with Cables (0.1 mΩ, 0 to 1 MHz) 32 A Planar Shunt
3024873 500 A Shunt with Cables (0.1 mΩ, 0 to 0.2 MHz)
3024692 LG Shunt Cables for High Current Shunts

Cables & Adaptors


3024661 Measurement Cable Set (for one power phase)
3024704 Fluke Norma WYE Adaptor (external accessory
box)

Printer Accessories
3024650 Printer Cable for Fluke Norma 5000
(RS232-Centronics)
Vibration Tester

With the Fluke 810 Vibration Tester you will be able to control unplanned
downtime, prevent recurring problems, set repair priorities and manage
your resources with an entirely new approach to vibration testing. In three
quick, easy steps, the new Fluke 810 helps you locate and diagnose com-
mon mechanical problems and prioritize their repair actions. The combi-
nation of powerful algorithms and a database of real-world measurement
experience make the Fluke 810 the most advanced troubleshooting tool
for mechanical maintenance teams who need an answer now.
810 Vibration Tester

New
Motor diagnosis and repair in three simple steps
The Fluke 810 Vibration Tester is the Features and benefits
most advanced troubleshooting tool cation and location of
for mechanical maintenance teams the most common mechanical faults
who need an answer now. The unique (bearings, misalignment, unbalance,
diagnostic technology helps you quickly looseness) focus maintenance efforts
identify and prioritize mechanical on root cause, reducing unplanned
problems, putting the expertise of a downtime
vibration analyst in your hands. • Fault severity scale with four severity
levels help you prioritize maintenance
Use the vibration tester to: work
• Troubleshoot problem equipment and • Repair recommendations advise
understand the root cause of failure technicians on corrective action
• Survey equipment before and after • On-board context sensitive help provide
rm the real-time tips and guidance to new
Fluke 810
repair users
• Commission new equipment and • 2 GB expandable on-board memory
ensure proper installation provide enough space for your
able proof of equipment machinery’s data
condition and drive investment in • Self-test functions ensure optimal
repair or replacement performance and more time on the job
• Prioritize and plan repair activities and • Laser tachometer for accurate machine
ciently dent
Set-up • Anticipate equipment failures before diagnoses
they happen and take control of spare • Tri-axial accelerometer reduces
parts inventories measurement time by 2/3 over single
• Train new or less-experienced axis accelerometers
dence and • Viewer PC Software expands data
skill across the team storage and tracking capacity
• Color LCD display and intuitive
multilingual, icon-based user interface
Measure promote use right out of the box

Specifications
(Check the Fluke web for detailed specifications)
Diagnose
Diagnostic specifications
Standard faults Unbalance, looseness, misalignment and bearing failures
Analysis for Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps,
piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/
Language support: lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed
eng, ger, fre, ita, spa, por coupled machines, spindles
Machine rotational 200 rpm to 12000 rpm
speed range
Diagnosis details Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details,
cited peaks, spectra
Electrical specifications
Ranging Automatic
A/D converter 4 channel, 24 bit
Usable bandwith 2 Hz to 20 kHz
Included Accessories Sampling 51.2 kHz
Digital signal Automatically configured anti-alias filter, high-pass filter, decimation, overlapping,
Tri-axial TEDS accelerometer, accelerometer processing functions windowing, FFT, and averaging
magnet mount, accelerometer mounting Sampling rate 2.5 kHz to 50 kHz
pad kit with adhesive, accelerometer quick Dynamic range 128 dB
disconnect cable, laser tachometer and Amplitude accuracy ±0.1 dBV
storage pouch, smart battery pack with cable FFT resolution 800 lines
and adapters, shoulder strap, adjustable Spectral windows Hanning
hand strap, Viewer PC application software, Frequency units Hz, orders, cpm
mini-USB to USB cable, getting started guide, Amplitude units in/sec, mm/sec, VdB (US), VdB (Europe)
Non-volatile nemory SD micro memory card, 2 GB internal + user accessible slot for additional storage
illustrated quick reference guide, users
manual CD-ROM, instructional training CD-
ROM, hard carrying case.
Battery type: Lithium-ion, 14.8 V 2.55 Ah Warranty: Three years on tester
Size (HxWxD): 186 x 267 x 70 One year on sensor and tachometer
Weight: 1.9 kg
Ordering Information
Fluke 810 Vibration Tester

Vous aimerez peut-être aussi