Vous êtes sur la page 1sur 2

2-channel DIY Multi-purpose

Remote Control RC-210 ( 1 transmitter)


RC-220 ( 2 transmitters)
. . . for autogate & other applications Model : RC-230 ( 3 transmitters)

Features :
1) Can be set to operate in momentary mode (K1 & K2) or bistable mode
by setting the slide switch (* see details below)
2) Long control range
3) AC/DC operation

Relay (K1) N.O.


Button A - AC/DC
+ 12~24V
Relay (K2) N.O. Operating
mode
Button C Terminal block select switch

S/R No.: _______________

K2 K1 - +
A A A A A A A A
7 6 5 4 3 2 1 0
K2 K1 (+) H
M
(-) L
LED 2 LED 1 T

( L = (-), H=(+), O= open or floating )


OPERATING MODES
Momentary (slide switch at position "M")
Press button "A" : Relay K1 willl be ON momentarily (remains ON until button is released)
Press button "C" : Relay K2 willl be ON momentarily (remains ON until button is released)
Press button "B" : No effect
Press button "D" : No effect

Bi-stable (slide switch at position "T")


Press button "A" : Relay K1 willl be ON & latched (K2 off)
Press button "C" : Relay K2 willl be ON & latched (K1 off)
Press button "B" : This will turn OFF both relays
Press button "D" : This will turn OFF both relays

Button C controls Relay (K2)


Button A controls Relay (K1)

C A
D B
TX9904-4 Button B (or D, if any) is the Master reset
button that turns off both relays
in the bi-stable mode
Schematic

Dual modes : T - latched & M - momentary


Power supply : AC or DC 12 ~ 24V
+12V +5V
AC/DC
12~24V

+
1N4002~7
I 7812 O I 78L05 O

-
470uF + G + 220uF G + 0.22uF K1 K2
35V 6.3V min
min - - 16V
min
-
Antenna
NC NC
24cm or 18cm
(315MHz 433.92MHZ) +5V COMM
COMM
+12V
0.01 uF NO NO

LED LED
K1 K2
+Vcc
- + 1 18 470 470
A0 Vdd ~ 1N4002~7 ~
RF 1N4002~7 510Ù
Opt 510Ù
Receiver A1 VT
Module A2 OSC K1, K2 : DC 12V
OSC
680K miniature, SPDT
A3
RX208 GND relays
A4 IN
or RX9927
A5 D0

A6 D1
3.9K 3 x NPN transistors
A7 D2
(2SC1815, etc)
GND D3
3.9K M (momentary)
IC :
PT2272-L4 S1
(or equivalent) 3.9K 1N4148 +
- T (latched)
220uF
6.3V min
Data from transmitter TX9904-4
Trsnsistor Voltage regulators :
Data bits * C1815, C945, 78L05
Button etc.,
Do D1 D2 D3
A 0 0 0 1 E Voltage regulators :
(K1) B O I
C G 7812
B 0 0 1 0
* when power is first applied I
C 0 1 0 0 (K2) O
to the circuit, the data bits will G
be reset to 0000 (both K1 & K2
D 1 0 0 0
are in the de-energized state)

* Component values in the actual products subject to change without prior notice