Vous êtes sur la page 1sur 6

Staple here!

Installation instructions

Resident building intercom 1 family


touch line evolution

RFID secure keyless entry

Call
APE.1F1.x&x
APE.1S1.x&x
Communication: FULL-DUPLEX hands-free
Audio monitoring

Gate opening
Open lock alert

3 volume levels + turned off


Different ringtones to choose from
Auxiliary function:
e.g.: auto gate/garage door opening

Extensions:
+3 additional indoor terminals
+3 additional outdoor panels
+1 doorbell: main indoor terminal connection APE.1S0.x&x APE.1F0.x&x

www.electra.ro

Downloaded from www.Manualslib.com manuals search engine


1 Overv iew
1.1 Essential components of the installation
( aparent ) ( îngropat )
Programming

(Red)
TAG.ELT.PRG
35 × 62 × 7 mm
Access

YEM.21x (DC) APE.1S1.x&x APE.1F1.x&x SAC.V1A.DIN ATE.Sxx


140 × 125 × 42 mm 260 × 110 × 35 mm 225 × 135 × 55 mm 141 × 130 × 73 mm 170 × 96 × 28 mm
YEM.32x (AC) APE.1S0.x&x APE.1F0.x&x TAG.ELT.000
140 × 125 × 42 mm 200 × 110 × 35 mm 225 × 135 × 55 mm 35 × 62 × 7 mm
Electromagnetic lock Outdoor panel Power supply Indoor terminal TAGs

1.2 Block diagram


(Optional)

ACC
12 V / 1,3 Ah
ATE.Sxx ATE.Sxx
APE.1S0 /2 Main Additional

SAC.V1A.DIN

DC/AC 3 3 3
/ / /
Lock

/2 (Optional)
AUX 3/
230 V a.c. Doorbell
OUTDOOR INDOOR

1.3 Technical features 1.4 Wiring


Power tension for SAC.V1A.DIN power supply 180 ... 256 V / 50 Hz APE.1xx.x&x ⟶ SAC.V1A.DIN
Power tension internal to the installation 12,0 ... 14,3 Vd.c. UTP CAT5 (AWG 24) cable for distances of max. 30m.
Power expenditure from the 230 V a.c. network Max. 0,2 A a.c. For longer distances: an additional cable (Cu 2 × 0,25 mm2) will
Access code memory 80 access codes for every outdoor panel be installed, doubling the power intake.
Extra outdoor panels main +max. 3 additional panels SAC.V1A.DIN ⟶ ATE.Sxx
main +max. 3 additional terminals: UTP CAT5 (AWG 25) cable for distances of max. 100m.
Extra indoor terminals
audio ATE.Sxx or audio ATB.Sxx For longer distances: an additional cable (Cu 2 × 0,25 mm2) will
Lock timer 5 seconds (cannot be modified) be installed, doubling the power intake.
Auxiliary command operates only on the main outdoor panel (address 1) APE.1xx.x&x ⟶ Electromagnetic lock
-30 ... +45 °C for outdoor components Flexible, multistrand cable, [Cu] 0,5 mm2 for distances of max. 20m.
Operating temperature range
0 ... +40 °C for indoor components
Maximum relative humidity 90% at +20 °C ATE.35S.x&x ⟶ Doorbell
2 × 0,25 mm2 Cable
Outdoor panel protection class IP 34

Bd. Chimiei 8 • 700291 Tel. +40 232 214.370 clientfeedback@electra.ro


Iași, ROMÂNIA Fax +40 232 232.830 office@electra.ro
J22/1225/1991 • RO1962470 www.electra.ro

Installation Instructions - edition: 17.09.2012 page 2/6

Downloaded from www.Manualslib.com manuals search engine


2 Mounting the components of the install ation
2.1 Outdoor panel
A.  Flush mounting

Before beginning ... 1


Align the edges
of the shell to
The outdoor panel is -5  the surface of the
c m
mounted at the entrance wall.
Cable fastening
to the property, on the No inset/offset! and guiding piece

body that is closest to the


pedestrian access gate.
2
≈17 cm 3
cable length
Main cable Lock cable Special screw with wrench
Name/Address
Sticker
Module
Print the label using:
B.  Surface mounting
Print Label ELT
www.electra.ro

1
Fastening clips
Cable fastening and
guiding piece
≈17 cm
cable length
(from the wall)
2

Main cable Lock cable

B4,2 × 60 Screw 3 TORKS Screw


(4 pcs.)

2.2 Power supply + Connection box (similar)


A.  DIN bar mounting B.  Surface mounting

2
DIN bar
3 Fastening clip A3,5 × 32 Screw Protection lid B2,9 × 9,5 Screw
(2 pcs.) (2 pcs.) (4 pcs.)

2.3 Indoor terminal

A3,5 × 35(32) Screw Cable fastening


(4 pcs.) and guiding
Before beginning ... pieces

1
The indoor terminal is mounted
at the location and height
discussed with the owner
(140cm recommended height).
2

≈18 cm
cable length
(from the wall)

page 3/6

Downloaded from www.Manualslib.com manuals search engine


3 Electric al connections
3.1 Installation connections
Recommendation:
Connection to the grounding system: locally or
Indoor terminal
from the distance (cable 1 x 0,75 mm2). Main

(Optional) +14 V
230 Va.c./50Hz Accumulator
Doorbell
button GND
Electrical panel ACC C/D
12V/1,3Ah
DBL
3 x 0,75 mm2 2 x 0,5 mm2
Cable F Cable
-ACC
N
+ACC
(Optional)
(Optional)
ORANGE ORANGE ORANGE
Door +14 V BROWN
+14 V +14 V BROWN +14 V BROWN +14 V
opening
button
GND GREEN
GND GND GREEN GND GREEN GND
C/D C/D C/D C/D C/D
BLUE (DATA) (DATA) BLUE BLUE
AUX -Uv +Uv Dbl
UTP CAT5 UTP CAT5 UTP CAT5 ATE.Sxx
(AWG 24) (AWG 24) (AWG 24)
GNV GNV ATE.Sxx ATB.Sxx
BUT
Indoor terminal Indoor terminal
DC LC Vin Vin Main additional
Electro- Auxiliary
magnetic LA/C command SAC.V1A.DIN
Lock (Open collector)
AC LA Power Supply

APE.1Sx
APE.1Fx
Outdoor panel

hub details 3.2 Lock connections


+14 V + (+14 V d.c.; 2A) general feed of the installation
(except for video communication) Drive current (DC)
GND 0 V (mass) general feed of the installation 3 x 0,5 mm2
Cable 4 x 0,5 mm2 ...
C/D audio and data communication Cable
BY BUT GND
+Uv + monitor display feed (+14 V d.c.) GND
0 V (mass) monitor display feed
+Y LC ...
-Uv
GNV 0 V (mass) video signal reference Y LA/C BY BUT
Vin (1 V vv) video signal input (also valid for V1, V2, V3 and V4) YEM.22x LA +Y LC
Vout (1 V vv) video signal output
Electromagnetic lock
Y LA/C
Outdoor panel
Ucam + (+12 V d.c.; 0,2 A) external video camera feed Drive Current (DC) YEM.21x LA
AUX auxiliary command output (open collector)
Electromagnetic lock
Dbl connection for a doorbell button Drive Current (DC) Outdoor panel
BUT connection for opening the lock
LC DC lock command Alternative current (AC)
LA/C DC/AC lock common
LA AC lock command BUT
+ACC + accumulator connection (+12V; max. 7 Ah) LC 2 x 0,5 mm2
Cable
-ACC - accumulator connection LA/C
F phase (230 V a.c. / 50 Hz) 12 Va.c. 230 Va.c.
null
LA
N
earthing Outdoor panel Transformer

Hubs specific to ELECTRA locks BY Y2 Y1


BY connection for opening the lock
YEM.32x
+Y
feed for Electra DC lock
Y Electromagnetic lock
Alternative current (AC)
Y1
feed for Electra AC lock
Y2
BUT
2 x 0,5 mm2
LC Cable
LA/C
12 Va.c. 230 Va.c.
LA

Outdoor panel Transformer

Electromagnetic lock
Alternative current (AC)

page 4/6

Downloaded from www.Manualslib.com manuals search engine


4 install ation setup
4.1 Verifying the accuracy of the connections and connecting the power supply
Check the correctness of the connections in the installation!
The +14 V, C/D and GND signals are the same for all components of the installation.
Any short-circuit between them will affect all the indoor terminals, causing them not to function.
Connect the power supply to the 230 V a.c. network through a 10 A automated fuse!
Optionally, the accumulator is connected to the +ACC;-ACC hubs of the SAC.V1A.DIN power supply.
Pay attention to the connection to the correct polarity of the outdoor accumulator!

Check the correct functioning of the power supply:


• The measured tension at the hubs of the power supply:  +14 V ⟷ GND / 13,8 ÷ 14,3 V d.c.
• Power supply signaling, according to the following table:
Signaling Observations Network tension Tension presence:  +14 V, +Uv
The installation is ready to function.
S1 permanent Green
1 If the audio or video communication is not functioning, check the
S2 permanent Green
status of fuses Sig. 1 and Sig. 2 from the power supply.
S1 alternating Red / Green The installation is functioning. 230 V ± 10% +14 V ⟷ GND  13,8 ÷ 14,3 V d.c.
2
S2 permanent Green Charging accumulator. 50 Hz +Uv ⟷ -Uv  13,5 ÷ 15,0 V d.c.
S1 alternating Red / Green
+ acoustic signaling The installation is functioning.
3
Faulty or uncharged accumulator: replace the accumulator!
S2 permanent Green
The installation is functioning only on audio communication,
S1 permanent/flashing Red +14 V ⟷ GND  10,5 ÷ 13,8 V d.c.
4 for a limited amount of time. NO:  0 V
S2 turned off +Uv ⟷ -Uv NO: 0 V
Check the power fuse from the network and fuse Sig. 3.
The installation is NOT functioning.
S1 flashing Green 230 V ± 10%
5 Shortcircuit in the installation on +14 V and/or +Uv. NO:  0 V
S2 turned off 50 Hz
Eliminate the shortcircuit and re-establish the connection!

4.2 Programming the Tags


The Red Programming TAG contains the unique code of the installation company.
When an outdoor panel reads a Programming TAG for the first time, it is personalized with the company’s unique code.
The code is permanently registered in the panel’s memory and can only be erased at the producer.

The personalized panel will not accept the Programming TAGs of other installation companies.
How to program the TAGs’ Access Codes in the memory of the outdoor panel:
The door on which the lock is mounted will remain closed the entire time it takes to program the TAGs! Entering the programming mode with the
door open will erase all acces codes.
1. Use the Red Programming TAG!  The panel enters the Programming Mode: [BEEP BEEP BEEEEEEP]
The Programming mode closes automatically if the panel is idle for more than 10 seconds or imediately by using the Programming TAG once more.
2. You now have a maximum of 10 sec. for each Access TAG.  You will hear the following sounds:
• [BEEP BEEP] when the Access Code has been succesfully memorized,
• [BEEP BEEP] when the TAG’s Access Code is already in the panel’s memory,
• [BEEP] when the panel has been idle for 10 seconds and is no longer in the Programming Mode.

To erase ALL the Access Codes from the panel’s memory:


This action cannot be undone! The panel will not recognize any Access TAG.
1. Enter the Programming Mode! (by using the Programming TAG)
2. Operate the lock’s button * for at least 6 seconds! Acoustic confirmation: [
BEEP BEEP
BEEP
]
*If the lock does not have a button, you need to short-circuit between the BUT and LC hubs (of the outdoor panel) for at least 6 seconds.

4.3 Programming the address of the additional outdoor panel


Remember:
The default address of all oudoor panels is 1.
The installation must have one outdoor panel with the adress 1. This will be the main panel.
The outdoor panels must have unique addresses within the installation.
The installation does not work if 2 panel’s share the same address!

How to program the additional outdoor panel:


The door on which the lock is mounted will remain closed the entire time it takes to program the additional panel!
1. Use the Red Programming TAG on the additional panel!  The panel enters the Programming Mode: [BEEP BEEP BEEEEEEP]
The Programming mode closes automatically if the panel is idle for more than 10 seconds or imediately by using the Programming TAG once more.
2. Press any key! [BEEP] when the panel’s address increases by +1, [BEEP BEEP BEEP] when the panel is bak to having address 1.
For the following 10 seconds, the additional panel is still in the Programming Mode and you may proceed to program its Access TAGs.

page 5/6

Downloaded from www.Manualslib.com manuals search engine


4.4 Programming the additional indoor terminals
If the installation contains just 1 indoor terminal, these steps are not necessary.
All indoor terminals leave the producer with address 1.
The main indoor terminal will nOT be programmed.
Operatorul 1 is programming from the main outdoor panel (address 1).

Operator 1 Steps Operator 2


Main outdoor panel Additional terminal

Step 0
All LEDs are off.

Step 1
Press both keys at the same time and
Operator 1 will hear [BEEEEEEEEP] in the outdoor hold until Operator 1 is done programming*.
panel.  Afterwards proceed to Step 2. * You will hear the first [BEEP] by touching the two keys and
ENTERING
programming mode the second [BEEP] when the terminal has been programmed
ENTERING
  Hold the keys pressed until you hear programming mode
the second [BEEP]!

Step 2 Keep holding the keys


pressed!
Press the apartment’s key, as many times as it
is shown in the table below:
( for every key you press you hear: [BEEP]  )

Operator 2 Main Additional 1 Additional 2 Additional 3


Indoor ×2 ×3 ×4 Red/White LED
during programming mode
terminal (twice) (three times) (four times)

Step 3 Step 3
The panel makes a [BEEP] for confirmation. You will hear the second [BEEP].
You can now release the keys!

EXITING
programming mode You have succesfully programmed an indoor terminal.
Call to check! EXITING
programming mode

We encourage you to program the additional indoor terminals at the head office.  With the devices laid out on a table, one operator follows the same steps.
Label the devices you program so you don’t misplace them in the installation.

4.5 Functions and adjustments


1. Check anywhere within the installation, during the The installation has been adjusted by the producer for audio
call and the communication, that the power tension communication to suit standard functioning conditions.
between +14 V ⟷ GND is higher than 12,0 V.
How to adjust the volume of the indoor terminal:
2. Check the functions of the indoor terminals and the outdoor When the LED is Red, the terminal is silent.
panels: call, communication, access, audio monitoring.
By pressing the    key you change between
When calling from outside, all indoor terminals will ring, but
different volume levels (White LED).
just the one you answer from can be used during the call.
After the verifications, leave the indoor terminal on Open Volume:
→ white LED on.

How to choose the terminal’s ringtone:


1. Simultaneously press and hold keys: !
2. Release the keys a few seconds after begins flashing Red/White!
3. Press to switch between ringtones.
4. Press to set the ringtone.

page 6/6

Downloaded from www.Manualslib.com manuals search engine

Vous aimerez peut-être aussi