Académique Documents
Professionnel Documents
Culture Documents
VARION® C-POWER
Combining power and performance
VARION® C-POWER — Ultimate all-in-one system
Engineered to exceed
The VARION® C-POWER range of CHP units
introduces a new era of heat and electrical power
generation. With class leading efficiencies, a host
of standard features plus supremely compact
designs, all models are perfect for commercial
applications. They are also compatible with the
ELCO range of wall mounted and floor standing
boilers to satisfy peak periods of demand.
Smart control
An integral touchscreen colour display provides easy
adjustment of settings, while temperatures, runtimes,
operation conditions, as well as the power and heat
generation are displayed in detailed graphics and tables.
System integration
VARION® C-POWER is suitable for cascade CHP
installations of up to three units. In addition, all models
can integrate seamlessly with other ELCO products to
offer an optimised system that is customised to every
application.
FB 07-097 ErP-Label VARION® C-POWER 5.0
Remote access
All VARION® C-POWER units are equipped with
a modem for remote monitoring, management
ELCO GmbH VARION® C-POWER 5.0
and analysis of the unit via a smartphone or tablet.
As standard, a 24-month mobile data allowance is
A++
A++
supplied, which can be extended on request (with
A + full service included). Data is stored on a secure
A
B server via live tracking for evaluation and support.
C
D
E
F
G
Highest environmental standards
12
VARION® C-POWER units are certified
to the highest
A++ efficiency class kW
for outputs from 5.0-30.0 kWel –
66 dB
maximising energy savings and reducing CO2 emissions.
2015 811/2013
2 3
VARION® C-POWER — One range for all commercial applications
VARION® C-POWER MODEL S VARION® C-POWER MODEL M VARION® C-POWER MODEL M+ VARION® C-POWER MODEL L
• Available in two performance classes: • Available in four performance classes: • Available in two performance classes: • Available in three types with
- 5.0 kWel - 11.0 kWel - 25.0 kWel 50.0 kWel performance:
- 7.2 kWel - 16.0 kWel - 30.0 kWel - standard
- 20.0 kWel - condensing unit
• Suitable for: • Suitable for:
- 21.0 kWel - high temperature unit (up to 93/83 °C
- apartment buildings - residential complexes
flow/return temperature)
- small commercial properties • Suitable for: - large hotels
- medium sized hotels - residential complexes - large commercial properties • Suitable for:
• Compatible with LPG - large hotels - industrial applications
• Compact dimensions
- large commercial properties - energy production
• Compact dimensions
• Compatible with LPG - heat intensive installation
e.g. swimming pools
• Compact dimensions
• Compact dimensions
76cm 79.8cm
68.6cm
62cm
Eletrical Heat Engine Noise Eletrical Heat Engine Noise Eletrical Heat Engine Noise Eletrical Heat Engine Noise
demand: demand: manufacturer: emission: demand: demand: manufacturer: emission: demand: demand: manufacturer: emission: demand: demand: manufacturer: emission:
20,000- 60,000- Toyota 51dB(A)* 60,000- 180,000- Toyota 50-52dB(A)* 100,000- 20,000- Yanmar 51dB(A)* 400,000 800,000 MAN 63dB(A)*
50,000 100,000 130,000 300,000 250,000 40,000 kWh kWh
kWh kWh kWh kWh kWh kWh
4 5
Technical data VARION® C-POWER
Product VARION® VARION® VARION® VARION® VARION® VARION® Product VARION® VARION® VARION® VARION® VARION®
C-POWER C-POWER C-POWER C-POWER C-POWER C-POWER C-POWER C-POWER C-POWER 50.0 C-POWER 50.0 C-POWER 50.0
5.0 7.2 11.0 16.0 20.0 21.0 25.0 30.0 Standard High temp CV
Rated electrical power (1) kWel 5 7.2 11 16 20 21 Rated electrical power (1) kWel 25 30 50 50 50
Rated thermal power (2) kWth 12.2 18.4 25.5 38.2 46.2 50.5 Rated thermal power (2) kWth 54.9 63.1 85 80 100
Electrical power modulation kWel 2.9 - 5.0 3.9 - 7.2 7.5 - 11.0 9.5 - 16.0 10.7 - 20.0 10.7 - 21.0 Electrical power modulation kWel 12.5 - 25.0 15.0 - 30.0 25.0 - 50.0 25.0 - 50.0 25.0 - 50.0
Thermal power modulation kWth 7.9 - 12.2 12.3 - 18.4 16.8 - 26.4 27.5 - 38.2 29.1 - 46.2 29.1 - 50.5 Thermal power modulation kWth 34.8 - 54.9 40.9 - 63.1 49.0 - 85.0 49.0 - 80.0 49.0 - 100.0
Electrical efficiency ŋel % 30.3 30.4 31.0 31.1 32.1 32.1 Electrical efficiency ŋel % 32.5 33.5 35.0 35.0 35.0
Thermal efficiency ŋth % 77.0 79.1 74.5 76.9 77.1 77.1 Thermal efficiency ŋth % 71.4 70.5 59.4 55.9 69.9
Total efficiency ŋtot % 107.3 109.5 105.5 108.0 109.2 109.2 Total efficiency ŋtot % 103.9 104.0 94.4 90.9 104.9
Energy input kWhHi 16.6 24.4 38.0 51.4 62.5 65.5 Energy input kWhHi 76.9 89.6 143.0 143.0 143.0
Natural gas consumption (G20) m³/h 1.52 2.34 3.49 4.72 5.73 6.01 Natural gas consumption (G20) m³/h 7.06 8.22 13.12 13.12 13.12
Liquid gas consumption (G31) kg/h 1.29 1.90 2.95 3.99 4.86 n/a Liquid gas consumption (G31) kg/h n/a n/a n/a n/a n/a
f pe 2009 0.374 0.383 0.423 0.280 0.293 0.295 f pe 2009 0.319 0.280 0.203 0.216 0.172
Primary energy saving % 29.8 30.5 28.3 31.1 32.0 32.0 Primary energy saving % 29.1 29.7 29.9 27.9 35.2
ErP energy efficiency label (3) A++ A++ A++ A++ A++ A++ ErP energy efficiency label (3) A++ A++ n/a n/a n/a
Sound power level Lw dB 66 66 65 67 68 68 Sound power level Lw dB 67 67 80 80 80
Noise emission dB(A) @1m 51 51 50-52 50-52 50-52 50-52 Noise emission dB(A) @1m 51 51 63 63 63
Maintenance interval h 10000 10000 8500 6000 6000 6000 Maintenance interval h 8000 8000 5000 3000 5000
Max. flow temperature ºC 93 93 93 93 93 93 Max. flow temperature ºC 90 90 90 93 90
Max. return temperature ºC 70 70 70 70 70 70 Max. return temperature ºC 70 70 70 83 70
Max. working pressure bar 2.5 Max. working pressure bar 2.5
Max. ambient temperature ºC 30 30 30 30 30 30 Max. ambient temperature ºC 30 30 30 30 30
Engine Toyota Toyota Toyota Toyota Toyota Toyota Engine YANMAR YANMAR MAN MAN MAN
Cylinders 3 3 4 4 4 4 Cylinders 4 4 4 4 4
Cubic capacity l 1 1 2.2 2.2 2.2 2.2 Cubic capacity l 3.3 3.3 4.6 4.6 4.6
Engine oil l 26 26 59 59 59 59 Engine oil l 110 110 180 180 180
Generator type Asynchronous Generator type Asynchronous Synchronous
Speed rpm 1550 1550 1540 1540 1540 1530 Speed rpm 1530 1530 1500 1500 1500
Exhaust gas temperature (4) ºC 72 87 87 89 95 95 Exhaust gas temperature (4) ºC 95 95 95 100 85
Dimensions module LxWxH 1160 x 620 1160 x 620 1410 x 686 1410 x 686 1410 x 686 1410 x 686 Dimensions module LxWxH 1640 x 760 1640 x 760 2180 x 798 2180 x 798 2180 x 798
mm mm
incl. mounted parts x 1100 x 1100 x 1240 x 1240 x 1240 x 1240 incl. mounted parts x 1410 x 1410 x 1670 x 1670 x 1670
Weight (5) kg 395 395 750 750 785 785 Weight (5) kg 950 950 1.650 - 1.860 1.650 - 1.860 1.650 - 1.860
Electrical connection V/Hz 400/50 400/50 400/50 400/50 400/50 400/50 Electrical connection V/Hz 400/50 400/50 400/50 400/50 400/50
Electrical connection cable cross 5x4mm² Cu, 5x4mm² Cu, 5x10mm² Cu, 5x10mm² Cu, 5x10mm² Cu, 5x10mm² Cu, 5x16mm² Cu, 5x16mm² Cu, 5x35mm² Cu, 5x35mm² Cu, 5x35mm² Cu,
mm² Electrical connection cable cross section mm²
section max. 50m max. 50m max. 50m max. 50m max. 50m max. 50m max. 100m max. 100m max. 50m max. 50m max. 50m
Electrical connection fuse rating A 25 25 50 50 50 50 Electrical connection fuse rating A 63 63 100 100 100
FB 07-097 ErP-Label VARION® C-POWER 5.0 FB 07-098 ErP-Label VARION® C-POWER 7.2 FB 07-099 ErP-Label VARION® C-POWER 11.0 FB 07-100 ErP-Label VARION® C-POWER 16.0 FB 07-101 ErP-Label VARION® C-POWER 20.0 FB 07-102 ErP-Label VARION® C-POWER 21.0 FB 07-103 ErP-Label VARION® C-POWER 25.0 FB 07-104 ErP-Label VARION® C-POWER 30.0
1) Performance data according to ISO 3046/I-2002, tolerance 5% 1) Performance data according to ISO 3046/I-2002, tolerance 5%
2) Heating capacity specification, tolerance 8% ELCO GmbH VARION® C-POWER 5.0 ELCO GmbH VARION® C-POWER 7.2 ELCO GmbH VARION® C-POWER 11.0 ELCO GmbH VARION® C-POWER 16.0
ELCO GmbH VARION® C-POWER 20.0
ELCO GmbH VARION® C-POWER 21.0
2) Heating capacity specification, tolerance 8% ELCO GmbH VARION® C-POWER 25.0
ELCO GmbH VARION® C-POWER 30.0
5) Model L partially filled, without noise insulation element = 1,650kg 5) Model L partially filled, without noise insulation element = 1,650kg
F F F F F F F F
G G G G G G G G
12 kW 18 kW 25 kW 38 kW 46 kW 50 kW 50 kW 57 kW
66 dB 66 dB 65 dB 67 dB 68 dB 68 dB 67 dB 67 dB
2015 811/2013 2015 811/2013 2015 811/2013 2015 811/2013 2015 811/2013 2015 811/2013 2015 811/2013 2015 811/2013
REV: Version 1 Verteiler: REV: Version 1 Verteiler: REV: Version 1 Verteiler: REV: Version 1 Verteiler: REV: Version 1 Verteiler: REV: Version 1 Verteiler: REV: Version 2 Verteiler: REV: Version 2 Verteiler:
Erstellung: H. Metz, M. Specken, 21. September 2015 Alle Mitarbeiter Erstellung: H. Metz, M. Specken, 21. September 2015 Alle Mitarbeiter Erstellung: H. Metz, M. Specken, 21. September 2015 Alle Mitarbeiter Erstellung: H. Metz, M. Specken, 21. September 2015 Alle Mitarbeiter Erstellung: H. Metz, M. Specken, 21. September 2015 Alle Mitarbeiter Erstellung: H. Metz, M. Specken, 21. September 2015 Alle Mitarbeiter Erstellung: H. Metz, 28.09.2015 Alle Mitarbeiter Erstellung: H. Metz,28. September 2015 Alle Mitarbeiter
Prüfung/ Dirk Behrends Prüfung/ Dirk Behrends Prüfung/ Dirk Behrends Prüfung/ Dirk Behrends Prüfung/ Dirk Behrends Prüfung/ Dirk Behrends Prüfung/ Dirk Behrends Prüfung/ Dirk Behrends
Freigabe: Freigabe: Freigabe: Freigabe: Freigabe: Freigabe: Freigabe: Freigabe:
6 7
ELCO – a partner you can rely on
As a specialist partner, you can rely on ELCO‘s extensive system expertise, from planning right through
to servicing and maintenance. Our specially trained technicians are available around the clock to help
with the installation and commissioning of commercial installations – offering their experience and assistance
when you need it the most.
Status: VARION® C-POWER CHP 09/16. Subject to modifications. The use of any text,
images and/or drawings without written permission is an infringement of copyright.
More information
www.elco.co.uk