Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

DATA OF LAMP PHOTOMETRIC DATA Eff: 73.97 lm/W


MODEL Imax(cd) 82.30 S/MH(C0/180) 1.26
NOMINAL POWER(W) LOR(%) 100.0 S/MH(C90/270) 1.42
RATED VOLTAGE(V) 220 TOTAL FLUX(lm) 299.62 h UP,DN(C0-180) 0.0,49.9

NOMINAL FLUX(lm) 299.617 CIE CLASS DIRECT h UP,DN(C180-360) 0.0,50.1

LAMPS INSIDE 1 h up(%) 0.0 CIBSE SHR NOM 1.50


TEST VOLTAGE(V) 220 h down(%) 100.0 CIBSE SHR MAX 1.55

PLANAR ISOLUX DIAGRAM(UNIT:lx)


LUMINOUS INTENSITY DISTRIBUTION DIAGRAM S(m) C(DEG)
0
90

80
-/+180
-150 150 1
70

-120 120 60

2 50

-90 0 90 40

17 30
34 20 MH=1m
3 10
0
-60 51 60 65.0 24.0
57.0 8.10
UNIT:cd
68 49.0 4.10
C0/180,114.0
41.0 2.40
C30/210,126.2
-30 85 30 33.0 0.8100
C60/240,140.2
0 C90/270,145.7
AVERAGE BEAM ANGLE(50%):131.5 DEG

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 13

ZONAL FLUX DIAGRAM

ZONAL FLUX DIAGRAM:

g C0 C45 C90 C135 C180 C225 C270 C315 g F zone F total %lum,lamp

10 80.46 81.27 81.98 81.23 80.43 81.48 82.30 81.50 0- 10 7.792 7.792 2.6,2.6

20 76.26 78.92 80.80 78.80 76.18 79.17 81.19 79.19 10- 20 22.72 30.52 10.2,10.2

30 69.49 74.29 77.35 74.06 69.33 74.50 77.77 74.55 20- 30 35.41 65.93 22,22

40 60.51 67.46 71.73 67.17 60.21 67.63 72.14 67.69 30- 40 44.32 110.3 36.8,36.8

50 49.62 58.76 64.17 58.41 49.26 58.81 64.53 58.89 40- 50 48.46 158.7 53,53

60 37.23 48.44 54.90 48.07 36.84 48.36 55.10 48.41 50- 60 47.39 206.1 68.8,68.8

70 23.81 36.86 44.11 36.50 23.31 36.66 44.16 36.67 60- 70 41.31 247.4 82.6,82.6

80 10.56 25.00 32.74 24.67 9.918 24.98 33.10 24.99 70- 80 31.31 278.7 93,93

90 2.152 16.60 24.13 16.17 1.508 17.03 25.46 17.79 80- 90 20.90 299.6 100,100

100 90-100

110 100-110

120 110-120

130 120-130

140 130-140

150 140-150

160 150-160

170 160-170

180 170-180

DEG LUMINOUS INTENSITY:cd UNIT:lm

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 13

LUMINANCE LIMITATION CURVES

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

LUMINANCE LIMITATION CURVES


GLARE CLASS ILLUMINANCE (lx)
1.15 A 2000 1000 500 <=300
1.50 B 2000 1000 500 <=300
1.85 C 2000 1000 500 <=300
2.20 D 2000 1000 500 <=300
2.55 E 2000 1000 500 <=300
a b c d e f g h LUMINANCE cd/(m2)
G(DEG)
a b c d e f g h G(DEG) C0/180 C90/270
85
8
6 85 6926 35171

75 4 80 6848 20854
3 75 7379 16411
a/h
65 70 7839 14267
2
65 8154 13001

55 60 8384 12146
55 8559 11520

45 1 50 8692 11045
8 1000 2 3 4 5 6 8 10000 2 3 4
C0/180 C90/270 LUMINANCE (cd/(m2)) 45 8802 10667

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 13

CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

r cc 80% 70% 50% 30% 10% 0


rw 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0
r fc 20% 20% 20% 20% 20% 0
RCR RCR:Room Cavity Ratio Coefficients of Utilization(CU)
0.0 1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 .00
1.0 .00 .95 .90 .98 .93 .88 .93 .89 .85 .89 .86 .83 .85 .83 .80 .78
2.0 .86 .78 .71 .84 .76 .70 .80 .74 .68 .76 .71 .67 .73 .69 .65 .63
3.0 .74 .65 .58 .73 .64 .57 .69 .62 .56 .67 .60 .55 .64 .59 .54 .52
4.0 .65 .55 .48 .64 .55 .48 .61 .53 .47 .59 .52 .46 .56 .51 .46 .43
5.0 .58 .48 .41 .57 .48 .41 .55 .46 .40 .52 .45 .40 .51 .44 .39 .37
6.0 .52 .42 .35 .51 .42 .35 .49 .41 .35 .47 .40 .34 .46 .39 .34 .32
7.0 .47 .38 .31 .46 .37 .31 .44 .36 .31 .43 .36 .30 .42 .35 .30 .28
8.0 .43 .34 .27 .42 .33 .27 .41 .33 .27 .39 .32 .27 .38 .32 .27 .25
9.0 .39 .30 .25 .38 .30 .24 .37 .30 .24 .36 .29 .24 .35 .29 .24 .22
10.0 .36 .28 .22 .35 .27 .22 .34 .27 .22 .33 .27 .22 .33 .26 .22 .20

LAMPS LUMINAIRE BUDGETARY DIAGRAM


50
CONDITIONS
40 FLUX 5000lm
FACTOR 0.70
30
Hdown 0.00m
Hwork 0.00m
20 Ework(AVE) 100lx
r (%) cc w fc
70 50 30
50 30 20

10
9
8
7
6
5 H=7

4
6 H=7

3
6
5
4 5 4
2
10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k
AREA(m2)

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 13

WEC AND CCEC

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

r cc 80% 70% 50% 30% 10% 0


rw 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0
r fc 20% 20% 20% 20% 20% 0
RCR RCR:Room Cavity Ratio Wall Exitance Coeffcients(WEC)
0.0
1.0 .386 .219 .069 .378 .216 .069 .365 .209 .067 .352 .203 .065 .341 .197 .064
2.0 .339 .186 .057 .332 .183 .056 .320 .178 .055 .309 .173 .054 .299 .169 .053
3.0 .303 .161 .048 .297 .159 .048 .286 .155 .047 .277 .152 .046 .267 .148 .046
4.0 .274 .142 .042 .268 .141 .042 .259 .137 .041 .250 .134 .041 .242 .131 .040
5.0 .249 .127 .037 .245 .126 .037 .236 .123 .036 .228 .120 .036 .221 .118 .035
6.0 .228 .114 .033 .224 .113 .033 .217 .111 .032 .210 .109 .032 .203 .107 .032
7.0 .211 .104 .030 .207 .103 .029 .201 .101 .029 .194 .100 .029 .188 .098 .029
8.0 .195 .096 .027 .192 .095 .027 .186 .093 .027 .181 .092 .026 .175 .090 .026
9.0 .182 .088 .025 .179 .087 .025 .174 .086 .024 .169 .085 .024 .164 .083 .024
10.0 .171 .082 .023 .168 .081 .023 .163 .080 .023 .159 .079 .022 .154 .078 .022

r cc 80% 70% 50% 30% 10% 0


rw 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0
r fc 20% 20% 20% 20% 20% 0
RCR RCR:Room Cavity Ratio Ceiling Cavity Exitance Coefficients(CCEC)
0.0 .190 .190 .190 .163 .163 .163 .111 .111 .111 .064 .064 .064 .020 .020 .020
1.0 .186 .155 .128 .159 .133 .110 .109 .092 .076 .063 .053 .044 .020 .017 .014
2.0 .179 .132 .092 .153 .113 .080 .105 .078 .056 .060 .046 .033 .019 .015 .011
3.0 .171 .115 .070 .146 .099 .060 .101 .069 .042 .058 .040 .025 .019 .013 .008
4.0 .163 .102 .055 .140 .088 .048 .096 .061 .033 .056 .036 .020 .018 .012 .007
5.0 .155 .091 .044 .133 .079 .039 .092 .055 .027 .053 .032 .016 .017 .011 .005
6.0 .147 .083 .037 .127 .072 .032 .087 .050 .023 .051 .030 .014 .016 .010 .004
7.0 .140 .076 .032 .120 .066 .028 .083 .046 .019 .048 .027 .012 .016 .009 .004
8.0 .133 .070 .027 .114 .061 .024 .079 .043 .017 .046 .025 .010 .015 .008 .003
9.0 .126 .065 .024 .109 .057 .021 .076 .040 .015 .044 .024 .009 .014 .008 .003
10.0 .120 .061 .022 .104 .053 .019 .072 .037 .013 .042 .022 .008 .014 .007 .003

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 13

UGR(Unified Glare Rating) Table

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

ceiling/cavity 0.7 0.7 0.5 0.5 0.3 0.7 0.7 0.5 0.5 0.3
walls 0.5 0.3 0.5 0.3 0.3 0.5 0.3 0.5 0.3 0.3
working plane 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
Room dimensions Viewed crosswise Viewed endwise
x = 2H y = 2H 20.3 21.9 20.5 22.1 22.3 21.6 23.3 21.9 23.5 23.7
3H 21.9 23.4 22.2 23.7 23.9 24.0 25.5 24.3 25.8 26.0
4H 22.6 24.1 22.9 24.3 24.6 25.2 26.7 25.5 26.9 27.2
6H 23.1 24.5 23.4 24.8 25.1 26.5 27.9 26.9 28.2 28.5
8H 23.3 24.6 23.6 24.9 25.2 27.2 28.6 27.6 28.9 29.2
12H 23.4 24.7 23.8 25.0 25.3 28.0 29.3 28.4 29.6 29.9

4H 2H 21.3 22.8 21.6 23.0 23.3 22.3 23.8 22.6 24.0 24.3
3H 23.2 24.5 23.5 24.8 25.1 24.9 26.2 25.2 26.5 26.8
4H 24.0 25.2 24.4 25.6 25.9 26.3 27.5 26.7 27.8 28.2
6H 24.8 25.8 25.2 26.2 26.6 27.8 28.9 28.2 29.2 29.6
8H 25.0 26.0 25.4 26.4 26.8 28.6 29.6 29.0 30.0 30.4
12H 25.2 26.2 25.7 26.6 27.0 29.5 30.5 30.0 30.9 31.3

8H 4H 24.8 25.8 25.3 26.2 26.6 26.7 27.7 27.1 28.1 28.5
6H 25.9 26.7 26.3 27.1 27.6 28.5 29.3 28.9 29.7 30.2
8H 26.3 27.1 26.8 27.5 28.0 29.5 30.3 29.9 30.7 31.1
12H 26.7 27.4 27.2 27.9 28.3 30.7 31.3 31.1 31.8 32.3

12H 4H 25.0 26.0 25.5 26.4 26.8 26.7 27.7 27.2 28.1 28.5
6H 26.2 27.0 26.7 27.4 27.9 28.6 29.4 29.1 29.8 30.3
8H 26.8 27.5 27.3 28.0 28.4 29.7 30.4 30.2 30.8 31.3
Variations with the observer position at spacings:
S = 1.0H + 0.1 / - 0.2 + 0.1 / - 0.1
1.5H + 0.2 / - 0.3 + 0.2 / - 0.3
2.0H + 0.2 / - 0.5 + 0.2 / - 0.3

CIE Pub.117, 299.6 lm Total Lamp Luminous Flux Corrected (8log(F/F0) = -4.2)

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 13

UTILIZATION FACTORS TABLE

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

REFLECTANCE

Ceiling 0.8 0.8 0.8 0.7 0.7 0.7 0.5 0.5 0.5 0

Walls 0.7 0.5 0.3 0.7 0.5 0.3 0.7 0.5 0.3 0

Working plane 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0

ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5

k = 0.60 53 41 34 53 41 33 51 40 33 26

0.80 63 50 42 62 50 42 60 49 42 34

1.00 71 59 51 70 58 50 67 60 50 42

1.25 78 66 58 77 66 58 74 64 57 49

1.50 83 72 64 81 71 63 78 69 62 54

2.00 90 80 73 88 79 72 85 77 71 62

2.50 95 86 78 93 84 77 88 81 76 66

3.00 98 90 83 96 88 82 92 85 80 71

4.00 103 96 90 100 94 89 96 91 86 76

5.00 106 100 95 103 98 93 98 94 90 80

ROOM INDEX UF(total) Direct

According to DIN EN 13032-2 2004 Suspended SHRNOM = 1.25

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 13

ISOCANDELA DIAGRAM

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

90 10% 8.293
20% 16.59
80 30% 24.88
40% 33.17
70 50% 41.46
60% 49.76
60 70% 58.05
80% 66.34
50 90% 74.64
40

30

20
VERTICAL(DEG)

10

-10

-20 MAX = 82.929


MIN = 47.081
-30 AVG = 70.437
AVG/MAX = 0.85
-40 MIN/MAX = 0.57

-50

-60

-70
Imax:82.93(H0.0,V0.0)
-80 (At:C=270.0,Gamma=9.0)
UNIT: cd
-90
-90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
HORIZONTAL(DEG)

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 13

AAI Figure

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

Flux out:192.3 lm

1m 25.82,82.93lx 307.85cm

2m 6.454,20.73lx 615.70cm

3m 2.868,9.214lx 923.55cm

4m 1.613,5.183lx 1231.40cm

5m 1.033,3.317lx 1539.25cm

6m 0.7171,2.304lx 1847.10cm

7m 0.5269,1.692lx 2154.95cm

8m 0.4034,1.296lx 2462.80cm

9m 0.3187,1.024lx 2770.65cm

10m 0.2582,0.8293lx 3078.50cm

Height Eavg,Emax Angle:113.98deg Diameter


Note:The Curves indicate the illuminated area and the average
illumination when the luminaire is at different distance.

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 13

ISOLUX DIAGRAM

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

210.0' 105.0' 0.0' 105.0' 210.0'


262.5' 80.00m
3% 0.0062lx 0.0005778fc
5% 0.0104lx 0.000963fc
210.0' 64.00m
10% 0.0207lx 0.001926fc

30% 0.0622lx 0.005778fc


157.5' 48.00m
50% 0.1037lx 0.00963fc

105.0' 32.00m

52.5' 16.00m

0.0' 0.00m

52.5' 16.00m

105.0' 32.00m

157.5' 48.00m

210.0' 64.00m

262.5' 80.00m
64.00m 32.00m 0.00m 32.00m 64.00m
MOUNTING HEIGHT: 66'(20.0m)

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 13

LED Avg.L Report

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

AvgL cd/m2
L_0~180(65)av 7990
L_0~180(75)av 7170
L_0~180(85)av 6364
L_90~270(65)av 13074
L_90~270(75)av 16499
L_90~270(85)av 36000
L_45(65)av 11292
L_45(75)av 13336
L_45(85)av 26137
Standard: GB/T 29293-2012

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 12 Of 13

Planar Illuminance Curve

Planar Illuminance Curve


E(lx) MH = 20 m
0.25

C0/180

0.225 C90/270

0.2

0.175

0.15

0.125

0.1

0.075

0.05

0.025

0
-25 -20 -15 -10 -5 0 5 10 15 20 25
Distance(m)

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 13 Of 13

LUMINOUS DISTRIBUTION INTENSITY DATA

Test:U:220.52V I:0.0354A P:4.0503W PF:0.5182 Freq:49.99Hz Lamp Flux:299.617x1 lm

NAME: LN10-00430/6400K TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: PRIMEX GROUP SUR.: Shielding Angle:

Table--1 UNIT: cd
C(DEG)
g (DEG) 0 30 60 90 120 150 180 210 240 270 300 330
0 81.8 81.8 81.8 81.8 81.8 81.8 81.8 81.8 81.8 81.8 81.8 81.8
5 81.5 81.6 81.8 81.9 81.8 81.6 81.5 81.7 82.0 82.1 82.0 81.7
10 80.5 80.9 81.6 82.0 81.6 80.8 80.4 81.0 82.0 82.3 81.9 81.1
15 78.7 79.7 81.0 81.7 81.0 79.6 78.6 79.8 81.4 82.0 81.4 79.8
20 76.3 77.9 79.9 80.8 79.9 77.7 76.2 78.0 80.4 81.2 80.3 78.0
25 73.2 75.5 78.3 79.4 78.2 75.3 73.1 75.5 78.7 79.8 78.7 75.6
30 69.5 72.6 76.0 77.3 75.8 72.3 69.3 72.5 76.5 77.8 76.5 72.6
35 65.3 69.1 73.2 74.8 73.0 68.7 65.0 69.0 73.7 75.2 73.7 69.1
40 60.5 65.1 69.9 71.7 69.7 64.7 60.2 64.9 70.4 72.1 70.3 65.1
45 55.3 60.6 66.1 68.2 65.9 60.2 54.9 60.4 66.5 68.6 66.5 60.5
50 49.6 55.7 61.8 64.2 61.6 55.2 49.3 55.4 62.3 64.5 62.2 55.6
55 43.6 50.5 57.1 59.7 56.9 49.9 43.2 50.0 57.5 60.0 57.5 50.2
60 37.2 44.8 52.1 54.9 51.8 44.3 36.8 44.3 52.4 55.1 52.4 44.5
65 30.6 38.9 46.7 49.7 46.4 38.3 30.2 38.3 47.0 49.8 46.9 38.5
70 23.8 32.8 41.0 44.1 40.8 32.2 23.3 32.1 41.2 44.2 41.1 32.2
75 17.0 26.5 35.2 38.4 35.0 26.0 16.4 25.9 35.4 38.5 35.3 26.0
80 10.6 20.5 29.5 32.7 29.3 20.0 9.92 20.1 29.9 33.1 29.8 20.2
85 5.36 15.4 24.5 27.7 24.3 14.8 4.62 15.3 25.4 28.8 25.4 15.4
90 2.15 12.2 21.1 24.1 20.8 11.5 1.51 12.6 21.5 25.5 22.7 12.9

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 30.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.404.7
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:7.580m [K=1.0000]
Test Date:2019-03-19 Remarks:

Vous aimerez peut-être aussi