Académique Documents
Professionnel Documents
Culture Documents
CorePro LEDtube
Mains T8
17T8 PRO LED/48-3000 BB G 1PK 10/1
Philips LED T8 InstantFit Lamps are an ideal energy saving choice for existing linear
fluorescent fixtures.
Product data
T-Storage (Max) 65 °C
Dimensional drawing
A3 Product D1 D2 A1 A2 A3
A2 1PK 10/1
A1
D1
D2
Photometric data
1 x 2000 lm
80
16.0
200 hroom: 2.8 m hroom : 2.8 m
Reflectances: 0.70, 0.50, 0.20 Refl: 0.70 0.50 0.20
150 Maintenance factor: 1.0 m 22
40 Ceiling mounted
120o 120o Ceiling mounted
750 lx
100 25
12.0 : viewed endwise
50 30 Y : viewed crosswise
50 20
8.0
300 lx
60o 100 60o
10
150
γ
200 4.0
0
(cd/1000lm) 0o 10 30 50 70 90 (m2) 4.0 8.0 12.0 m 16.0
X
0-180o 90-270o
Utilisation factor table Luminance Table
Light output ratio 1.00
60 Service upward 0.27 Reflectances (%) for ceiling, walls and working plane (CIE) Plane 0.0 15.0 30.0 45.0 60.0 75.0 90.0
Room Cone
Service downward 0.73 0.80 0.80 0.70 0.70 0.70 0.70 0.50 0.50 0.30 0.30 0.00
45.0 6869 6834 6808 6869 7138 7877 9587
Index 0.50 0.50 0.50 0.50 0.50 0.30 0.30 0.10 0.30 0.10 0.00
50.0 6640 6586 6527 6534 6720 7375 9226
CIE flux code 36 64 85 73 100 k 0.30 0.10 0.30 0.20 0.10 0.10 0.10 0.10 0.10 0.10 0.00
55.0 6436 6375 6277 6221 6299 6840 8788
60.0 6275 6202 6079 5954 5908 6287 8313
UGRcen (4Hx8H, 0.25H) 24 0.60 0.40 0.38 0.38 0.37 0.36 0.29 0.27 0.22 0.25 0.21 0.17
0.80 0.50 0.47 0.47 0.46 0.44 0.37 0.34 0.29 0.31 0.27 0.22 65.0 6141 6073 5910 5721 5542 5697 7693
1.00 0.58 0.53 0.54 0.53 0.51 0.43 0.40 0.35 0.36 0.32 0.27 70.0 6051 5986 5795 5551 5248 5089 6959
1.25 0.65 0.60 0.62 0.59 0.57 0.50 0.46 0.41 0.42 0.38 0.31 75.0 6027 5959 5753 5472 5024 4493 6008
1.50 0.72 0.65 0.67 0.65 0.62 0.55 0.50 0.45 0.46 0.42 0.35 80.0 6048 5969 5783 5454 4894 3916 4586
2.00 0.81 0.72 0.76 0.72 0.69 0.63 0.57 0.53 0.52 0.49 0.41
85.0 6096 5992 5825 5521 4872 3531 2615
2.50 0.87 0.77 0.82 0.78 0.74 0.68 0.62 0.58 0.57 0.54 0.46
3.00 0.92 0.81 0.86 0.81 0.77 0.72 0.66 0.62 0.60 0.57 0.49 90.0 6196 6093 5917 5622 5029 3554 1913
2
4.00 0.98 0.85 0.92 0.86 0.81 0.77 0.71 0.67 0.65 0.62 0.53 (cd/m )
5.00 1.02 0.88 0.96 0.90 0.84 0.80 0.74 0.71 0.68 0.65 0.56
Ceiling mounted
2017-05-05
40
20
0
200 300 400 500 600 700 800
[nm] CalcuLuX Photometrics 4.5 Philips Lighting B.V. Page: 1/1
50
o
60o 100 60
150
200
o
(cd/1000lm) 0
o o
0-180 90-270
Lifetime
80 100
Failure rate in %
Failure rate in %
60 80
55
60
40 65
40
75
20
20
0 0
0 10000 20000 30000 40000 50000 60000 0 10000 20000 30000 40000 50000 60000
Time (hours)
Time (hours)
Mains DLC 17W 2000-2100lm 3000_5000K ND Mains DLC 17W 2000-2100lm 3000_5000K ND
60000 100
Lumen in %
50000 95
40000 90
Life time
B10L70
30000 85
80
20000 B50L70
75
10000
70
0 0 10000 20000 30000 40000 50000
45 55 65 75
Tc(°C) Burning hours
Mains DLC 17W 2000-2100lm 3000_5000K ND Mains DLC 17W 2000-2100lm 3000 5000K ND
100%
98%
Lumen (%)
96%
94%
92%
90%
55 60 65 70 75
Tc(°C)
© 2018 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or
completeness of the information included herein and shall not be liable for any action in reliance thereon. The
information presented in this document is not intended as any commercial offer and does not form part of any
quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered www.lighting.philips.com