Design of channel :

channel 240x85x9.5

Load Combination 85 mm

85
(Total Dead Load(Plate+ angles section+dead load of channel) +
Live Load) = 6 KN/m

240 mm

240
Maximum Bending Moment = 23.83 kNm from staad pro
Section Modulus( Z) = 300000 mm3 from table
13 mm

13
9.5
9.5mm

Actual Bending Stress(moment/section modulus z)(AISC:- F8-1)


=23830000 / 300000=79.43 N/mm2 Safe
Net Effective Ares of crossection (A) = 4230 mm2 from table

Actual shear stress=force/Area=18.4x1000


4230=4.34 N/mm2 Safe

Actual Bending stress and shear stress is Less than Allowable


Bending stress and shear stress

Design of Bolted connection between c-channel and concrete:-

SHEAR FORCE = 18.4 KN 4-M16x100 ANCHOR BOLT

(1) design SSt pipe ladder step

outer diameter

inner moment
Area

Shear
diameterof inertia

Section Modulus
area

length of udl
moment member

Shear udl line

steel stress
line load

stressfs==V/As
M/z ( 2*d*t for tube)
38.1 mm

28928.32263
35.1 mm

172.47344
1518.54712

400
.0394
mm

25.95
KNm

.394 KN

2.28 Mpa
mm4

mm2
mm3

Mpa < <165


110Mpa
Mpa safesafe

MOMENT ON BOLT =23.83 KNm

hilti ,HSA ,R,M16 = 59.3 KN mean ultimate resistance

for 4 bolt = 4x 59.3 =237.2 kN > 18.4 OK safe