Académique Documents
Professionnel Documents
Culture Documents
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010. All rights reserved
2 Id:0900d805803bc56d DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters
Table of Contents
This document has 50 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
DN985702 Id:0900d805803bc56d 3
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters
4 Id:0900d805803bc56d DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters Summary of changes
Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
DN985702 Id:0900d80580454953 5
Issue 9-0
Summary of changes DM - Interrogation of LAPD and SBUS Statistics Meters
The function of the command has been made more specific and param-
eters vi and ccha have been added. An example illustrating the use of
these parameters has been added. An execution printout has been
added.
DME EMPTY LAPD EVENT LOGS
The function of the command has been made more specific and param-
eters vi and ccha have been added. An example illustrating the use of
these parameters has been added.
6 Id:0900d80580454953 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DM - INTERROGATION OF LAPD AND SBUS STA-
TISTICS METERS
DN985702 Id:0900d8058041c472 7
Issue 9-0
DM - INTERROGATION OF LAPD AND SBUS STA- DM - Interrogation of LAPD and SBUS Statistics Meters
TISTICS METERS
8 Id:0900d80580332f0e DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMF INTERROGATE TRANSMITTED AND RE-
CEIVED FRAMES AND OCTETS
Parameters application, link set number, D-channel type: unit, measurement period: measurement
name info;
[ <unit> | A def ],
[ <measurement period> | P def ]:
D-channel type
P primary D-channel
S secondary D-channel
Enter the type of the D-channel whose data you want to interrogate. You can interrogate
the meter data concerning both D-channels (default), or the data concerning the primary
or secondary D-channel. The parameter is not obligatory.
unit
A active unit (default)
S spare unit
Enter the unit whose statistical meter data you want to interrogate.
measurement period
You can use this parameter to specify the measurement period. Enter
C cumulative meters, or
P periodic meters (default)
DN985702 Id:0900d8058045cc35 9
Issue 9-0
DMF INTERROGATE TRANSMITTED AND RE- DM - Interrogation of LAPD and SBUS Statistics Meters
CEIVED FRAMES AND OCTETS
Examples 1. To interrogate the values of the cumulative statistical meters of primary and second-
ary channels 1 to 3 and 5 of the primary rate access in the active unit, and to display
the names of the meters, give the following command:
DMF:,1&&3&5,:,C:D;
2. To interrogate the data on the cumulative statistical meters of all the existing primary
ET channels in the spare unit, give the command below. The names of the meters
are not to be displayed.
DMF:E,,P:S,C:;
3. To interrogate the data on the periodic statistical meters of all the existing primary
and secondary channels of the primary rate access, give the command below. The
names of the meters are not to be displayed.
DMF:::;
1 2 3 4 5
D-CHA TYPE 6 7 8 9 10
===== ==== ========== ========== ========== ========== ==========
10 Id:0900d8058045cc35 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMF INTERROGATE TRANSMITTED AND RE-
CEIVED FRAMES AND OCTETS
COMMAND EXECUTED
Interrogate the data concerning the periodic statistical meters of primary D-channels 1
to 3 and 5 of the primary rate access in the active unit. The names of the meters are not
to be displayed.
The execution printout of command DMF:,1&&3&5,P::; is as follows:
TRANSMITTED AND RECEIVED FRAMES AND OCTETS
1 2 3 4 5
D-CHA TYPE 6 7 8 9 10
===== ==== ========== ========== ========== ========== ==========
COMMAND EXECUTED
In the BSC, the meter counts of each D-channel may be followed by a message stating
that the D-channel has been combined with another D-channel and that the meter
counts are sums of the meter counts from the combined D-channels:
D-CHANNEL IS COMBINED WITH: 6
METERS ARE SUM OF BOTH D-CHANNELS
Combined D-channels can only occur in the Abis interface of the BSC.
The execution printout can be followed by one of these messages:
UNKNOWN D-CHANNEL NUMBER
The D-channel that you gave in the command does not exist.
NO D-CHANNELS FOUND
The D-channels that you gave in the command do not exist.
NO D-CHANNELS DEFINED
There are no D-channels in the system.
STATISTICS OK
The statistical processes return to the normal state, i.e., the above-mentioned unstable
situations causing an error are removed.
SWITCHOVER DURING INQUIRY
DN985702 Id:0900d8058045cc35 11
Issue 9-0
DMF INTERROGATE TRANSMITTED AND RE- DM - Interrogation of LAPD and SBUS Statistics Meters
CEIVED FRAMES AND OCTETS
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
12 Id:0900d8058045cc35 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMI INTERROGATE MISCELLANEOUS STATISTI-
CAL COUNTERS
Parameters application, link set number, D-channel type: unit, measurement period: measurement
name info;
[ <unit> | A def ],
[ <measurement period> | P def ]:
D-channel type
P primary D-channel
S secondary D-channel
Enter the type of the D-channel whose data you want to interrogate. You can interrogate
the meter data concerning both D-channels (default), or the data concerning the primary
or secondary D-channel. The parameter is not obligatory.
unit
A active unit (default)
S spare unit
Enter the unit whose statistical counters you want to interrogate.
measurement period
You can use this parameter to specify the measurement period. Enter
C cumulative meters, or
P periodic meters (default)
DN985702 Id:0900d805803b6884 13
Issue 9-0
DMI INTERROGATE MISCELLANEOUS STATISTI- DM - Interrogation of LAPD and SBUS Statistics Meters
CAL COUNTERS
Examples 1. To interrogate the values of the cumulative statistical meters of primary and second-
ary channels 1 to 3 and 5 of the primary rate access in the active unit, and to display
the names of the meters, give the following command:
DMI:,1&&3&5,:,C:D;
2. To interrogate the data on the cumulative statistical meters of all the existing primary
ET channels in the spare unit, give the command below. The names of the meters
are not to be displayed.
DMI:E,,P:S,C:;
3. To interrogate the data on the periodic statistical meters of all the existing primary
and secondary channels of the primary rate access, give the command below. The
names of the meters are not to be displayed.
DMI:::;
1 2 3 4 5
6 7 8 9 10
D-CHA TYPE 11 12
===== ==== ========== ========== ========== ========== ==========
14 Id:0900d805803b6884 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMI INTERROGATE MISCELLANEOUS STATISTI-
CAL COUNTERS
COMMAND EXECUTED
In the BSC, the meter counts of each D-channel may be followed by a message stating
that the D-channel has been combined with another D-channel and that the meter
counts are sums of the meter counts from the combined D-channels:
D-CHANNEL IS COMBINED WITH: 6
METERS ARE SUM OF BOTH D-CHANNELS
Combined D-channels can only occur in the Abis interface of the BSC.
The execution printout can be followed by one of these messages:
UNKNOWN D-CHANNEL NUMBER
The D-channel that you gave in the command does not exist.
NO D-CHANNELS FOUND
The D-channels that you gave in the command do not exist.
NO D-CHANNELS DEFINED
There are no D-channels in the system.
STATISTICS OK
The statistical processes return to the normal state, i.e., the above-mentioned unstable
situations causing an error are removed.
SWITCHOVER DURING INQUIRY
A switchover occurred during the meter data interrogation.
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
DN985702 Id:0900d805803b6884 15
Issue 9-0
DMQ INTERROGATE Q.921 ERROR COUNTERS DM - Interrogation of LAPD and SBUS Statistics Meters
Parameters application, link set number, D-channel type: unit, measurement period: measurement
name info;
[ <unit> | A def ],
[ <measurement period> | P def ]:
D-channel type
P primary D-channel
S secondary D-channel
Enter the type of the D-channel whose data you want to interrogate. You can interrogate
the meter data concerning both D-channels (default), or the data concerning the primary
or secondary D-channel. The parameter is not obligatory.
unit
A active unit (default)
S spare unit
Enter the unit whose statistical meter data you want to interrogate.
measurement period
You can use this parameter to specify the measurement period. Enter
C cumulative meters, or
P periodic meters (default)
16 Id:0900d8058030b442 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMQ INTERROGATE Q.921 ERROR COUNTERS
Examples 1. To interrogate the values of the cumulative statistical meters of primary and second-
ary channels 1 to 3 and 5 of the primary rate access in the active unit, and to display
the names of the meters, give the following command:
DMQ:,1&&3&5,:,C:D;
2. To interrogate the values of the cumulative statistical meters of all the existing
primary ET channels in the spare unit, give the command below. The names of the
meters are not to be displayed.
DMQ:E,,P:S,C:;
3. To interrogate the values of the periodic statistical meters of all the existing primary
and secondary channels of the primary rate access, give the command below. The
names of the meters are not to be displayed.
DMQ:::;
1 2 3 4 5
6 7 8 9 10
D-CHA TYPE 11 12 13 14 15
===== ==== ========== ========== ========== ========== ==========
DN985702 Id:0900d8058030b442 17
Issue 9-0
DMQ INTERROGATE Q.921 ERROR COUNTERS DM - Interrogation of LAPD and SBUS Statistics Meters
COMMAND EXECUTED
Interrogate the values of the periodic statistical meters of primary D-channels 1 to 3 and
5 of the primary rate access in the active unit. The names of the meters are not to be
displayed.
The execution printout of command DMQ:,1&&3&5,P::; is as follows:
Q.921 ERROR COUNTERS
1 2 3 4 5
6 7 8 9 10
D-CHA TYPE 11 12 13 14 15
===== ==== ========== ========== ========== ========== ==========
COMMAND EXECUTED
In the BSC, the meter counts of each D-channel may be followed by a message stating
that the D-channel has been combined with another D-channel and that the meter
counts are sums of the meter counts from the combined D-channels:
D-CHANNEL IS COMBINED WITH: 6
METERS ARE SUM OF BOTH D-CHANNELS
Combined D-channels can only occur in the Abis interface of the BSC.
The execution printout can be followed by one of these messages:
UNKNOWN D-CHANNEL NUMBER
The D-channel that you gave in the command does not exist.
18 Id:0900d8058030b442 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMQ INTERROGATE Q.921 ERROR COUNTERS
NO D-CHANNELS FOUND
The D-channels that you gave in the command do not exist.
NO D-CHANNELS DEFINED
There are no D-channels in the system.
STATISTICS OK
The statistical processes return to the normal state, i.e., the above-mentioned unstable
situations causing an error are removed.
SWITCHOVER DURING INQUIRY
A switchover occurred during the meter data interrogation.
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
DN985702 Id:0900d8058030b442 19
Issue 9-0
DMN INTERROGATE OCCASIONAL VALUES OF DM - Interrogation of LAPD and SBUS Statistics Meters
LINK SET METERS
Examples 1. To interrogate the occasional values of the meters of D-channel link set PXBNY,
give the following command:
DMN:PBXNY;
2. To interrogate the occasional values of the meters of D-channel link set TRX03, give
the following command:
DMN:TRX03;
Execution printouts When you interrogate the occasional values of the meters of D-channel link set PBXNY,
the data on the statistical meters of terminal function 2 of the signalling terminal 0 in the
PAU-1 is printed out.
The execution printout of command DMN:PBXNY; is as follows:
INTERROGATING STATISTICAL METERS OF D-CHANNEL LINK SET: PBXNY
20 Id:0900d80580410432 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMN INTERROGATE OCCASIONAL VALUES OF
LINK SET METERS
DL-DATA-REQUESTS. . . . . . . . . . . . . . 0000000000
DL-UNIT-DATA-REQUESTS . . . . . . . . . . . 0000000000
DL-DATA-INDICATIONS . . . . . . . . . . . . 0000000000
DL-UNIT-DATA-INDICATIONS. . . . . . . . . . 0000000000
CRC ERRORS. . . . . . . . . . . . . . . . . 0000000000
DELETED DL-DATA-REQUESTS . . . . . . . . . 0000000000
DELETED I FRAMES IN WINDOW. . . . . . . . . 0000000000
T200 EXPIRIES . . . . . . . . . . . . . . . 0000000000
FRAMING ERRORS. . . . . . . . . . . . . . . 0000000000
CLOCK SIGNAL MISSING. . . . . . . . . . . . 0000000000
IDLE COUNTER. . . . . . . . . . . . . . . . 0000000000
READ BUFFER CONGESTION. . . . . . . . . . . 0000000000
COMMAND EXECUTED
In the BSC, the last meter (READ BUFFER CONGESTION) may be followed by a
message stating that the D-channel has been combined with another D-channel and
that the meter counts are sums of the meter counts from the combined D-channels:
D-CHANNEL IS COMBINED WITH: 6
METERS ARE SUM OF BOTH D-CHANNELS
Combined D-channels can only occur in the Abis interface of the BSC.
The execution printout can be followed by one of these messages:
D-CHANNEL DOES NOT EXIST
The D-channel that you gave in the command does not exist.
PRIMARY ACCESS TERMINAL DOES NOT EXIST
The primary access terminal that you gave in the command does not exist.
DN985702 Id:0900d80580410432 21
Issue 9-0
DMN INTERROGATE OCCASIONAL VALUES OF DM - Interrogation of LAPD and SBUS Statistics Meters
LINK SET METERS
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
22 Id:0900d80580410432 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMT INTERROGATE OCCASIONAL VALUES OF
TERMINAL METERS
Parameters unit type, stage, unit index: primary access terminal index, terminal function index:
display mode;
stage
This parameter is only used in the SSU unit, and you can use it to specify the stage for
the unit. Enter the subscriber stage (0 - 9). The parameter is obligatory when the unit
type is SSU.
unit index
Enter the unit index that complies with the selected unit type. The parameter is obliga-
tory. If the unit type is SSU, the default value is the active unit.
display mode
This parameter specifies the display mode. Enter parameter value D if you want to
display the zero meters as well. If you do not want to display the zero meters, enter
parameter value N or omit the parameter altogether.
Examples 1. To interrogate the meter data on terminal function 1 in terminal 2 of CCSU 3, give
the command below. The zero meters are to be displayed.
DMT:CCSU,3:2,1:D;
2. To interrogate the meter data on terminal function 4 in terminal 2 of CCSU 3, give
the command below. The zero meters are to be displayed.
DMT:CCSU,3:2,4:D;
3. To interrogate the meter data on terminal function 2 in terminal 7 on stage 2 of the
active SSU, give the command below. The zero meters are not to be displayed.
DN985702 Id:0900d80580400d64 23
Issue 9-0
DMT INTERROGATE OCCASIONAL VALUES OF DM - Interrogation of LAPD and SBUS Statistics Meters
TERMINAL METERS
DMT:SSU,2:7,2;
4. To interrogate the meter data on terminal function 5 in terminal 4 of CAC 0, give the
command below. The zero meters are not to be displayed.
DMT:CAC,0:4,5:N;
Execution printouts Interrogate the data on the statistical meter of terminal function 2 in the active CAC 0.
Also include the zero meters.
The execution printout of command DMT:CAC,0:0,2:D; is as follows:
CAC-0 TERMINAL INDEX : 0 TERM FUNCT: 2 SAPI : 0
24 Id:0900d80580400d64 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMT INTERROGATE OCCASIONAL VALUES OF
TERMINAL METERS
DL-DATA-REQUESTS. . . . . . . . . . . . . . 0000000000
DL-UNIT-DATA-REQUESTS . . . . . . . . . . . 0000000000
DL-DATA-INDICATIONS . . . . . . . . . . . . 0000000000
DL-UNIT-DATA-INDICATIONS. . . . . . . . . . 0000000000
CRC ERRORS. . . . . . . . . . . . . . . . . 0000000000
DELETED DL-DATA-REQUESTS . . . . . . . . . 0000000000
DELETED I-FRAMES IN WINDOW. . . . . . . . . 0000000000
T200 EXPIRIES . . . . . . . . . . . . . . . 0000000000
FRAMING ERRORS. . . . . . . . . . . . . . . 0000000000
CLOCK SIGNAL MISSING. . . . . . . . . . . . 0000000000
IDLE COUNTER. . . . . . . . . . . . . . . . 0000000000
READ BUFFER CONGESTION. . . . . . . . . . . 0000000000
COMMAND EXECUTED
In the BSC, the last meter (READ BUFFER CONGESTION) may be followed by a
message stating that the D-channel has been combined with another D-channel and
that the meter counts are sums of the meter counts from the combined D-channels:
D-CHANNEL IS COMBINED WITH: 6
METERS ARE SUM OF BOTH D-CHANNELS
Combined D-channels can only occur in the Abis interface of the BSC.
The execution printout can be followed by one of these messages:
PRIMARY ACCESS TERMINAL DOES NOT EXIST
The primary access terminal that you gave in the command does not exist.
TERMINAL FUNCTION DOES NOT EXIST
There are no terminal functions in use.
COMMUNICATION ERROR IN TERMINAL METER INQUIRY
The PSDPRO is not able to obtain the data on the statistical meters of the primary
access terminals before time-out.
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
DN985702 Id:0900d80580400d64 25
Issue 9-0
DMT INTERROGATE OCCASIONAL VALUES OF DM - Interrogation of LAPD and SBUS Statistics Meters
TERMINAL METERS
26 Id:0900d80580400d64 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMU INTERROGATE OCCASIONAL VALUES OF
FUNCTIONAL UNIT METERS
stage
Enter the subscriber stage, but only when you are interrogating a channel of the SUB
unit. The value range of the parameter is 0 - 9. This parameter is obligatory when the
unit type is SUB.
unit index
Enter the index of the unit (0 - 2047), based on the selected unit type. This parameter is
obligatory.
Examples 1. To interrogate the occasional values of the D-channel meters of the CLS-1, give the
command below.
DMU:CLS,1;
2. To interrogate the occasional values of the D-channel meters of the SUB-0-5, give
the command below.
DMU:SUB,0,5;
3. To interrogate the occasional values of the D-channel meters of the ET-112, give the
command below.
DMU:ET,112;
Execution printouts Interrogate the occasional values of the D-channel meters of the CLS-0. This interroga-
tion gives the statistical meter data of terminal function 2 of the signalling terminal 0 in
the active CAC.
The execution printout of command DMU:CLS,0; is as follows:
INTERROGATING STATISTICAL METERS OF D-CHANNEL: CLS-0
DN985702 Id:0900d805804256e2 27
Issue 9-0
DMU INTERROGATE OCCASIONAL VALUES OF DM - Interrogation of LAPD and SBUS Statistics Meters
FUNCTIONAL UNIT METERS
DL-DATA-REQUESTS. . . . . . . . . . . . . . 0000000000
DL-UNIT-DATA-REQUESTS . . . . . . . . . . . 0000000000
DL-DATA-INDICATIONS . . . . . . . . . . . . 0000000000
DL-UNIT-DATA-INDICATIONS. . . . . . . . . . 0000000000
CRC ERRORS. . . . . . . . . . . . . . . . . 0000000000
DELETED DL-DATA-REQUESTS . . . . . . . . . 0000000000
DELETED I FRAMES IN WINDOW. . . . . . . . . 0000000000
T200 EXPIRIES . . . . . . . . . . . . . . . 0000000000
FRAMING ERRORS. . . . . . . . . . . . . . . 0000000000
CLOCK SIGNAL MISSING. . . . . . . . . . . . 0000000000
IDLE COUNTER. . . . . . . . . . . . . . . . 0000000000
READ BUFFER CONGESTION. . . . . . . . . . . 0000000000
COMMAND EXECUTED
28 Id:0900d805804256e2 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMU INTERROGATE OCCASIONAL VALUES OF
FUNCTIONAL UNIT METERS
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
DN985702 Id:0900d805804256e2 29
Issue 9-0
DML INTERROGATE LAPD EVENT LOGS DM - Interrogation of LAPD and SBUS Statistics Meters
Parameters channel, funit, stage, index: unit type, stage, unit index: event class, event: start date,
start time: stop date, stop time;
Syntax
DML: (CHANNEL = <link set number> | FUNIT = <functional unit> |
[STAGE = <stage>] | INDEX = <functional unit index>):
[<unit type> | <unit index> | SSU | <stage> | <unit index> | <all> def ]:
[[<stop date> | <today> def] | [<stop time> | <current time> def ]];
functional unit
Enter the type of the functional unit (FUNIT) whose D-channel events you want to inter-
rogate from the PSLOGF. The available values vary according to the exchange type and
its configuration: CLS, SUB, ET, AET, AMX, VXCU, TCSM, FNIM, but you cannot use
this parameter if parameter CHANNEL has been given.
30 Id:0900d8058037f4bc DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DML INTERROGATE LAPD EVENT LOGS
stage
Enter the stage for the unit (STAGE). Use this parameter only if the type for the func-
tional unit is SUB, in which case the parameter is obligatory. The possible values are
within the range 0 .. 9.
unit type
Enter the type of the computer unit whose events you want to interrogate from the
PSLOGF. The possible values for the parameter vary according to the exchange type
and its configuration, e.g. BCSU, CCSU, LSU, PAU, M, OMU, CAC, SSU, ANCU, SCU,
IWCU, TSU, CRSU. The parameter is optional. The default is "all unit types".
stage
This parameter is only used in the SSU unit. Enter the stage for the unit. The possible
values are within the range 0 .. 9. The parameter is obligatory when the unit type is SSU.
unit index
Enter the unit index that complies with the selected computer unit type. The value range
for the parameter varies for different unit types. The parameter is obligatory if the
computer unit type has been entered. If the unit type has not been entered, the unit index
cannot be entered, either. In this case, the default is the whole index value range.
event class
Enter the event class whose events you want to interrogate. The possible values are
within the range 1 .. 4. This parameter is optional and the default is "all event classes".
event
Enter the event you want to interrogate from the log file. The possible values are within
the range 1 .. 63. You can only enter events belonging to the event class you specified.
The parameter can only be entered if the event class has been entered. The parameter
is optional and the default is "all events in the given event class", but if the class has not
been entered, then the default is "all events".
start date
Enter the start date after which the events are to be interrogated. The parameter is
optional and the default is "current date."
start time
Enter the start time after which the events are to be interrogated. The parameter is
optional and the default is 00:00:00.
stop date
Enter the stop date before which the events are to be interrogated. The parameter is
optional and the default is "current date".
stop time
Enter the stop time before which the events are to be interrogated. The parameter is
optional and the default is "current time".
DN985702 Id:0900d8058037f4bc 31
Issue 9-0
DML INTERROGATE LAPD EVENT LOGS DM - Interrogation of LAPD and SBUS Statistics Meters
Only the first parameter block is obligatory and the others are optional.
Examples 1. To interrogate all events saved on the current day on D-channel 1 in the primary rate
access, give the following command:
DML:CHANNEL=1;
2. To interrogate all events saved on the current day on the D-channel in CLS-1, give
the following command:
DML:FUNIT=CLS,INDEX=1;
3. To interrogate all events saved on the current day on D-channel 1, located in the
primary rate access of computer unit PAU-0, give the following command:
DML:CHANNEL=1:PAU,0;
4. To interrogate all events saved on the current day on the D-channel in SUB-1-1, give
the following command:
DML:FUNIT=SUB,STAGE=1,INDEX=1;
5. Give the command below to interrogate events no. 7 (D-CHANNEL PROTECTION)
belonging to the first event class on D-channel 10, which is located in the primary
rate access of computer unit PAU-0. The events have been saved on the current
day.
DML:CHANNEL=10:PAU,0:1,7;
6. Give the command below to interrogate events no. 2 (D-CHANNEL CREATED)
belonging to the first event class of the CLS-1 located in computer unit M-0. Specify
the inquiry to apply to the events that took place between 3.6.1998 at 12.00 o'clock
and 5.6.1998 at 12.00 o'clock.
DML:FUNIT=CLS,INDEX=1:M,0:4,48:1998-06-03,12-00-00:1998-06-
05,12-00-00;
7. Give the command below to interrogate all events saved on the current day on D-
channel 10 of all computer units. Further specify the inquiry to apply to events saved
between 12.30pm and 13.30pm.
DML:CHANNEL=10:::,12-30-00:,13-30-00;
8. Give the command below to interrogate all events saved on the current day on D-
channel 10 of the primary rate access in all computer units. Further specify the
inquiry to apply to events that have been saved between 00.00 and 07.00am.
DML:CHANNEL=10::::,07-00-00;
Additional informa- After the system restart, the log files both in the active and spare unit are empty.
tion After the unit with the log file has restarted, the contents of this log file are reset.
32 Id:0900d8058037f4bc DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DML INTERROGATE LAPD EVENT LOGS
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
Execution error If an error occurs, the system outputs the general execution error message of MML com-
messages mands.
DN985702 Id:0900d8058037f4bc 33
Issue 9-0
DME EMPTY LAPD EVENT LOGS DM - Interrogation of LAPD and SBUS Statistics Meters
functional unit
Enter the type of the functional unit (FUNIT) whose D-channel events are to be emptied
from the PSLOGF. The available values vary according to the exchange type and its
configuration: CLS, SUB, ET, AET, AMX, VXCU, TCSM, FNIM, but you cannot use this
parameter if parameter CHANNEL has been given.
stage
Enter the stage for the unit (STAGE). Use this parameter only if the type for the func-
tional unit is SUB, in which case the parameter is obligatory. The possible values are
within the range 0 .. 9.
Examples 1. To empty the whole event log file, give the following command:
DME:;
34 Id:0900d8058036e99a DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DME EMPTY LAPD EVENT LOGS
2. To empty the event records for D-channel 1 in the primary rate access, give the fol-
lowing command:
DME:CHANNEL=1;
3. To empty the event records saved from the D-channel in CLS-1, give the following
command:
DME:FUNIT=CLS,INDEX=1;
4. To empty the event records saved from the D-channel in SUB-1-1, give the following
command:
DME:FUNIT=SUB,STAGE=1,INDEX=1;
Execution printouts The program outputs the number of emptied event records. If there are no records for
the requested D-channel, the number of emptied records is printed out as zero.
The execution printout of the command is as follows (10 records fulfilling the conditions):
10 EVENT RECORDS CLEARED
COMMAND EXECUTED
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
Execution error If an error occurs, the system outputs the general execution error message of MML com-
messages mands.
DN985702 Id:0900d8058036e99a 35
Issue 9-0
DMP INTERROGATE OCCASIONAL VALUES OF DM - Interrogation of LAPD and SBUS Statistics Meters
DPNSS/DASS2 METERS
counter type
You can use this parameter to select whether the D-channel counters or DLC counters
or both are to be interrogated. By default, both counter types are interrogated.
36 Id:0900d8058037077d DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMP INTERROGATE OCCASIONAL VALUES OF
DPNSS/DASS2 METERS
DN985702 Id:0900d8058037077d 37
Issue 9-0
DMP INTERROGATE OCCASIONAL VALUES OF DM - Interrogation of LAPD and SBUS Statistics Meters
DPNSS/DASS2 METERS
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
Execution error If an error occurs, the system outputs the general execution error message of MML com-
messages mands.
38 Id:0900d8058037077d DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMM INTERROGATE MF COUNTERS
unit index
Enter the index of the computer unit type you selected. The value range of the parameter
varies depending on the unit type and the equipping. The parameter is not obligatory,
and its default value is the whole index range of the given unit type.
MF function
Enter the MF function whose counters you want to interrogate. The parameter is not
obligatory, and its default value is all MF functions. Enter one of the following values:
PBRU, R2, DTS, CCO, DTR2_REC, CHSAT, R1AAR, AON_SENDING,
MODEM_SIGN, DETECT_D_TONE, NAT_MF_1 or ANSI_MF.
Examples 1. To interrogate the counters for data on MF function PBRU in the MFSU-0, give the
following command:
DMM:MFSU,0:PBRU;
2. To interrogate the counters for data on MF function PBRU in all MFSU units, give
the following command:
DMM:MFSU,:PBRU;
3. To interrogate the counters for data on all MF functions in CAC-1, give the following
command:
DMM:CAC,1:;
4. To interrogate the counters for data on all MF functions in all MFSU units, give the
following command:
DMM:MFSU,:;
Additional informa- You can only interrogate counter values in computer units whose state is WO-EX. Oth-
tion erwise, the system generates an error message reporting a time-out.
DN985702 Id:0900d80580442d21 39
Issue 9-0
DMM INTERROGATE MF COUNTERS DM - Interrogation of LAPD and SBUS Statistics Meters
When the state of a computer unit is some other than WO-EX, no new data is collected
in the counters, but old counter values are preserved.
Execution printouts When the first (or a single) counter group of an MF function in a computer unit is being
reported, the printout first shows the data on the computer unit and the start time of the
counters. After this, the name of the MF function is output and then the actual counter
data.
Every counter produces three different values; the occasional value, the value of the
previous hour and the cumulative value beginning from the start-up of the counter.
After the counter values, the printout shows the number of devices of the requested MF
function type that are in reserved state at the output moment. Furthermore, the printout
includes the date and time when the cumulative counters were last reset.
The full counter names corresponding to the abbreviations are shown at the bottom of
the printout.
The execution printout of example 1 is as follows:
COMPUTER: MFSU-0
COUNTERS START: 1998-06-23 00:00:00
FUNCTION OF MF DEVICE: PBRU
COUNTER
TYPE SERVREQ SERVACC SERVREC TIMEOUT AVETIME MAXRES DEVCOUNT
======================================================================
CURRENT 00000000 00000000 00000000 00000000 00000 00000 00000
PREV HOUR 00000000 00000000 00000000 00000000 00000 00000 00000
TOTAL 00000000 00000000 00000000 00000000 00000 00000 00000
RESERVED DEVICES COUNT AT THE MOMENT: 1234
TOTAL COUNTERS UPDATED ON THE HOUR AND CLEARED AT 1998-06-23 00:00:00
COUNTER NAMES:
SERVREQ ....... SERVICE REQUEST COUNT
SERVACC ....... SERVICE REQUEST ACCEPTED
SERVREC ....... SERVICE REQUEST REJECTED
TIMEOUT ....... SERVICE TIME OUT
AVETIME ....... DEVICE AVERAGE RESERVE TIME IN
MAXRES ........ MAXIMUM DEVICE RESERVE COUNT
DEVCOUNT....... DEVICE COUNT
COMMAND EXECUTED
The execution printout of example 2 is as follows (units 0 and 3 are in state WO-EX):
COMPUTER: MFSU-0
COUNTERS START: 1998-06-23 00:00:00
FUNCTION OF MF DEVICE: PBRU
COUNTER
TYPE SERVREQ SERACC SERVREC TIMEOUT AVETIME MAXRES DEVCOUNT
======================================================================
CURRENT 00000000 00000000 00000000 00000000 00000 00000 00000
PREV HOUR 00000000 00000000 00000000 00000000 00000 00000 00000
TOTAL 00000000 00000000 00000000 00000000 00000 00000 00000
RESERVED DEVICES COUNT AT THE MOMENT: 1234
TOTAL COUNTERS UPDATED ON THE HOUR AND CLEARED AT 1998-06-23 00:00:00
COMPUTER: MFSU-3
COUNTERS START: 1998-06-23 00:00:00
40 Id:0900d80580442d21 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMM INTERROGATE MF COUNTERS
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
Execution error If an error occurs, the system outputs the general execution error message of MML com-
messages mands.
DN985702 Id:0900d80580442d21 41
Issue 9-0
DMD EMPTY MF COUNTERS DM - Interrogation of LAPD and SBUS Statistics Meters
unit index
Enter the index of the computer unit type you selected. The value range of the parameter
varies depending on the unit type and the equipping. The parameter is not obligatory,
and its default value is the whole index range of the given unit type.
MF function
Enter the MF function whose counters you want to reset. The parameter is not obliga-
tory, and its default value is all MF functions. Enter one of the following values: PBRU,
R2, DTS, CCO, DTR2_REC, CHSAT, R1AAR, AON_SENDING, MODEM_SIGN,
DETECT_D_TONE, NAT_MF_1 or ANSI_MF.
Examples 1. To reset the cumulative counters of MF function PBRU in the MFSU-0, give the fol-
lowing command:
DMD:MFSU,0:PBRU;
2. To reset the cumulative counters of MF function PBRU in all MFSU units, give the
following command:
DMD:MFSU,:PBRU;
3. To reset the cumulative counters of all MF functions in the CAC-1, give the following
command:
DMD:CAC,1:;
4. To reset the cumulative counters of all MF functions in all MFSU units, give the fol-
lowing command:
DMD:MFSU,:;
Additional informa- You can only reset the cumulative counters in computer units whose state is WO-EX.
tion Otherwise, the system generates an error message reporting a time-out.
42 Id:0900d8058036708f DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMD EMPTY MF COUNTERS
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
Execution error If an error occurs, the system outputs the general execution error message of MML com-
messages mands.
DN985702 Id:0900d8058036708f 43
Issue 9-0
DMV INTERROGATE SBUS COUNTERS DM - Interrogation of LAPD and SBUS Statistics Meters
display type
Use this parameter to specify the display type. Enter the unit whose counter data you
want to interrogate. The default is "counters of both HWAT and CLAB units". Enter one
of the following:
HWAT counters of HWAT unit
CLAB counters of CLAB unit
BOTH counters of both HWAT and CLAB units.
sbus
Use this parameter to select the supervision bus whose counter data you want to inter-
rogate. The default value is both supervision buses. Enter one of the following:
0 counters from SBUS 0
1 counters from SBUS 1.
Examples 1. To interrogate the counter data on the HWAT unit side (SBUS 1) for CLAB units 1-
10, give the command below. The counter names are not to be displayed.
DMV:1&&10,HWAT,1;
2. To interrogate the counter data on the CLAB unit side (SBUS 0) for CLAB units 1, 4
and 8, give the command below. The counter names are to be displayed.
DMV:1&4&8,CLAB,0:Y;
3. To interrogate the counter data on both the HWAT and CLAB unit sides (both super-
vision buses) for CLAB units 3 and 30-40, give the command below. The counter
names are not to be displayed.
44 Id:0900d805804570f4 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMV INTERROGATE SBUS COUNTERS
DMV:3&30&&40;
4. To interrogate the counter data for CLAB unit 12 (SBUS 0), give the command
below. The counter names are not to be displayed.
DMV:12,CLAB,0;
5. To interrogate the counter data on the HWAT unit side (both supervision buses) for
CLAB units 20-23, give the command below. The counter names are to be dis-
played.
DMV:20&&23,HWAT:Y;
6. To interrogate the counter data on all CLAB units (both supervision buses) for both
the HWAT and the CLAB units, give the command below. The counter names are
not to be displayed.
DMV:;
Execution printouts Output the counter data on the HWAT unit side of SBUS 1 for CLAB units 1-10. The
counter names are not to be displayed.
The execution printout of command DMV:1&&10,HWAT,1; is as follows:
TRANSMITTED AND RECEIVED FRAMES AND OCTETS FROM HWAT:
SBUS CLAB STAT ESTAB TX-FR RX-FR TXMSG RXMSG DLMSG TIMER CRCER OTHER
==============================================================================
1 1 CONN 35 15534 3335 1151 311 5 211 35 6
1 2 DISC 0 0 0 0 3 89 5423 1296 19
1 3 CONN 3 780 670 234 435 21 22 1 2
1 4 CONN 1 55 10 11 17 12 10 11 10
1 5 CONN 10 294 102 53 100 78 9 0 3
1 6 CONN 78 5210 3333 1132 67 120 100 44 8
1 7 CONN 98 1984 544 444 209 56 66 14 21
1 8 CONN 1 11111 1245 988 111 99 6 3 11
1 9 CONN 5 312 123 22 9 12 1 2 1
1 10 UNEQ 0 0 0 0 0 0 0 0 0
COMMAND EXECUTED
Output the counter data on the CLAB unit side of both supervision buses for CLAB units
3, 6 and 9. The counter names are not to be displayed.
The execution printout of command DMV:3&6&9,CLAB; is as follows:
TRANSMITTED AND RECEIVED FRAMES AND OCTETS FROM HWAT:
DN985702 Id:0900d805804570f4 45
Issue 9-0
DMV INTERROGATE SBUS COUNTERS DM - Interrogation of LAPD and SBUS Statistics Meters
COMMAND EXECUTED
Output the counter data on both the HWAT and CLAB unit sides of SBUS 0 for CLAB
units 0, 12, 13 and 14. The counter names are to be displayed.
The execution printout of command DMV:0&12&14,,0:Y; is as follows:
TRANSMITTED AND RECEIVED FRAMES AND OCTETS FROM HWAT:
SBUS CLAB STAT ESTAB TX-FR RX-FR TXMSG RXMSG DLMSG TIMER CRCER OTHER
==============================================================================
0 0 CONN 1 11702 7715 7 18 0 35 0 0
0 12 DISC 0 148 0 0 0 3 0 0 0
0 13 CONN 3 9758 9757 25 25 0 0 0 1
0 14 CONN 1 9762 9755 24 24 0 7 0 0
COUNTERS NAMES:
46 Id:0900d805804570f4 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMV INTERROGATE SBUS COUNTERS
COMMAND EXECUTED
After the execution, one of the following messages may be displayed:
NO HWAT IN UNIT
No HWAT unit exists in the system.
NO CLAB UNITS EXISTS
No CLAB units exist in the system.
CLAB COUNTERS NOT AVAILABLE
No counter values received from the CLAB unit before time-out.
NO COUNTER SUPPORT
The CLAB unit does not support counters.
NO CONNECTION
No connection to the CLAB unit.
Semantic error If an error occurs, the system outputs the general semantic error message of MML com-
messages mands.
DN985702 Id:0900d805804570f4 47
Issue 9-0
DMX INTERROGATE BIT ERROR RATE DM - Interrogation of LAPD and SBUS Statistics Meters
Parameters minimum bit error rate, maximum bit error rate: PCM identification, BCF identification:
minimum amount of crc errors, maximum amount of crc errors, minimum amount of
t200 expiries, maximum amount of t200 expiries: day selection;
Syntax
DMX: [[ MINBER = <Minimum bit error rate> |
MAXBER = <Maximum bit error rate> ] | <all> def ]:
[[ BCF = <BCF identification> <all> def ] |
[ PCM = <External PCM number(s)> | <all> def ]]...:
[[ MINCRC = <Minimum number of CRC errors> |
MAXCRC = <Maximum number of CRC errors> |
MINT200 = <Minimum number of T200 expiries> |
MAXT200 = <Maximum number of T200 expiries> ] | <all> def ]:
[ <day> | <today> def ];
48 Id:0900d805803eb5a4 DN985702
Issue 9-0
DM - Interrogation of LAPD and SBUS Statistics Meters DMX INTERROGATE BIT ERROR RATE
day
You can use this parameter to specify measurement period. Enter
TODAY todays measurements (default)
YESTERDAY yesterdays measurements
Examples 1. To interrogate todays bit error rates in D-channels which bit error rates are above
1E-6, give the command below:
DMX:MINBER=6;
2. To interrogate todays bit error rates in D-channels which bit error rates are between
1E-6 and 1E-3 and are related to PCM numbers between 32 and 34, give the
command below:
DMX:MINBER=6,MAXBER=3:PCM=32&&34;
3. To interrogate yesterdays bit error rates in D-channels which are related to second
BCF, give the command below:
DMX::BCF=4::YESTERDAY;
4. To interrogate yesterdays bit error rates in D-channels which are related to fourth
BCF and which CRC error count is above 20000, give the command below:
DMX::BCF=4:MINCRC=20000:DAY=YESTERDAY;
Execution printouts To interrogate LAPD links which are bit error rate is over 1E-4.
The execution printout of command DMX:BER=4; is as follows:
INTERROGATING BIT ERROR RATE OF D-CHANNELS
DN985702 Id:0900d805803eb5a4 49
Issue 9-0
DMX INTERROGATE BIT ERROR RATE DM - Interrogation of LAPD and SBUS Statistics Meters
Semantic error If an error occurs, the system outputs a general MML semantic error message.
messages
Execution error If an error occurs, the system outputs a general MML execution error message.
messages
50 Id:0900d805803eb5a4 DN985702
Issue 9-0