EA HP EA FP EAT/m ER PG

MES
Kwh/m PU S/. Kwh/m PU S/. Kwh Kvarh/m ERFAC PU S/. Kw/m PU
Nov-16 152463 0.1672 25,491.8 701851 0.1451 101,838.6 854,313.7 609732 353,437.45 0.0326 11,522.06 1614 25.94
Dec-16 108437 0.1649 17,881.3 535885 0.143 76,631.5 644,321.7 483853 290,556.07 0.0326 9,472.13 1600 25.77
Jan-17 115074 0.1661 19,113.7 469283 0.1442 67,670.6 584,356.9 289523 114,216.31 0.0321 3,666.34 1329 25.91
Feb-17 109868 0.1662 18,260.0 441719 0.1466 64,756.0 551,587.1 230480 65,003.85 0.0325 2,112.63 1373 28.31
Mar-17 75420 0.1662 12,534.9 312509 0.1469 45,907.6 387,929.2 189122 72,743.36 0.0326 2,371.43 1304 24.19
Apr-17 76002 0.1662 12,631.6 305662 0.1469 44,901.70 381,664.2 201176 86,676.97 0.0326 2,825.67 1153 29.34
Promedio 106,210.70 0.17 17,652.22 461151.43 66,951.00 567,362.14 333,980.98 163,772.34 0.0325 5,322.60 1395.36 26.58
Máximo 152462.70 0.17 25,491.76 701851.03 101,838.58 854,313.73 609,731.57 353,437.45 0.0326 11,522.06 1614.00 29.34
Total 637264.22 1.00 105,913.30 2766908.60 401,706.01 3,404,172.8 2,003,885.9 982,634.02 0.0326 32,033.87
Total/año 1965268.03 63871.21
Ahorro US$ 19,354.91
PG PD
FP HP/m CT LEY 28749
Total S/.
S/. Kw-m S/Kw-m S/.
41867.16 1614 12.39 19997.46 0.81 120 0.79
### 200,717.03
41231.96 1600 12.39 19823.98 0.80 125 0.54
### 165,040.85
34436.71 1607 12.34 19830.37 0.90 130 0.67
### 144,717.80
38861.87 1603 12.28 19690.97 0.92 120 0.67
### 143,681.54
31534.93 1605 11.74 18845.62 0.90 125 0.46
### 111,194.41
33820.98 1604 12.29 19717.76 0.88 125 0.53
### 113,897.72
36958.94 1606 12.24 19651.03 0.61 146,535.78
41867.16 1614 12.39 19997.46 0.92 0.85 200,717.03
221753.62 117906.15 879,249.34
CALCULO DEL BANCO DE CONDENSADORES

CONDICION Nº 1: FACTOR DE POTENCIA PROMEDIO

POTENCIA ACTIVA (kW): 1,614.00 PG MAX

COS(φ1) = 0.92269 Promedio


φ1 = 22.68

CONDICION FUTURA

POTENCIA ACTIVA (kW): 1,614.00 PG MAX

COS(φ2) = 0.97
φ2 = 14.07

VALOR DEL BANCO DE POTENCIA REACTIVA

Qc = 269.90 kVar >>>> 300


INVERSION US$/KVAR 20 6000
SE DEBERA ELEGIR UN BANCO AUTOMATICO DE 350 kVar
Del mismo modo se repartirá entre las subestaciones asociadas al suministro.

CALCULO DE RENTABILIDAD DE UNA INVERSION.

DEL CALCULO ANTERIOR SE OBSERVA QUE SE DEBE DE REALIZAR UNA INVERSION


DE 20,000 US$ PARA DEJAR DE PAGAR ENERGIA REACTIVA.
LA VIDA UTIL ESTIMADA DEL EQUIPO ES DE 10 AÑOS Y EL COSTO DE MANTENIMIENTO
ES DE US$ 200 /AÑO

CALCULO DE LA RENTABILIDAD:

I= 6,000 US$

M= 200 US$

R= 1,965,268.03 kvarh/año.

P= 0.0325 US$/kWh

P' = 0.034125 US$/kWh

V= 10 AÑOS

A= 66,864.77 US$/AÑO (R*P' -M)


D= 600 US$/AÑO (I/V)

d= 12% TASA DE INTERES ANUAL


LUEGO DE LA TABLA 20.17 SE OBTIENE F= 5.019

F= 5.019 TABLAS

VA = 335,594.29 (F*A) VALOR ACTUAL DEL AHORRO EN US$.


CALCULO DE LOS PARAMETROS DE SEGUNDO ORDEN:
1) RELACION INVERSION/AHORRO (PAYBACK)

X= 1.08 MESES
2) TASA DE RETORNO DE LA INVERSION.

TIR = 1104.41 %; ES MAYOR A 20%, O SEA ESTA MUY BIEN.


3) RELACION BENEFICIO COSTO:(B/C)

B/C = 55.93 B/C =VA/I = (F*A)/I.


>>> B/C, MAYOR A 1; ES UN VALOR BUENO.
ES EVIDENTE QUE LOS TRES PARAMETROS 1), 2) Y 3) ACONSEJAN CLARAMENTE HACER LA
INVERSION.

EJEMPLO:
LOS TRABAJOS DE EFICIENCIA ENERGETICA SE OBTIENE UN AHORRO ANUAL
NETO DE US$ 10.000,00.

EL PRIMER AÑO, SE SUPONE QUE NO EXISTE INFLACION Y QUE EL PRECIO DE


ELECTRICIDAD O COMBUSTIBLE NO VARIA A LO LARGO DE LOS SIGUIENTES AÑOS.

ESTO QUIERE DECIR QUE SE SEGUIRA OBTENIENDO EL MISMO AHORRO ANUALMENTE


SI EL AHORRO SE COLOCA AL 10% DE INTERES, LAS DIFERENCIAS ENTRE LOS
INTERESES DE ESTAS IMPOSICIONES SON MAYORES A LO LARGO DEL TIEMPO.

CALCULO DE INTERESES ANUALES:

IMPOSICIONES INTERESES.
1er AÑO 2do AÑO 3 er AÑO 4to AÑO 5to AÑO
1er AÑO 1000 1100 1210 1331 1464.1
2do AÑO 1000 1100 1210 1331
3er AÑO 1000 1100 1210
4to AÑO 1000 1100
5to AÑO 1000

EN EL CUADRO ANTERIOR SE APRECIA LOS INTERESES ANUALES QUE SE


PRODUCIRAN AL FINAL DE CADA AÑO IMPOSICIONES DE US$ 10.000
REALIZADAS AL PRINCIPIO DEL MISMO AÑO
ORES

EVALUACION ECONOMICA DE LAS INVERSIONES: EN EFICIENCIA ENERGETICA.


DEFINICIONES BASICAS:
I: COSTO DE LA INVERSION, INCLUYE LA MANO DE OBRA Y MATERIALES NECESARIOS
PARA DEJAR EL EQUIPO INSTALADO(US$)

M: COSTO ANUAL DE MANTENIMIENTO Y OPERACION DEL EQUIPO(US$)

R: REDUCCION ANUAL DEL CONSUMO(kWh/a, gal/a) OBTENIDO CON EL EQUIPO


POR OBJETO DE LA AUDITORIA.

P: PRECIO ACTUAL DEL COMBUSTIBLE O ELECTRICIDAD (US$/ton, gal, kWh).

P': PRECIO MEDIO PREVISTO DEL COMBUSTIBLE O ELECTRICIDAD A LO LARGO DE LA


VIDA UTIL PREVISTA DEL EQUIPO(US$/tonelada, gal, kWh).

V: VIDA UTIL ESTIMADA DEL EQUIPO.

A: AHORRO ANUAL NETO.ESTE AHORRO ES LA DIFERENCIA ENTRE EL AHORRO DEBIDO


A LA REDUCCION DEL CONSUMO DE ENERGIA Y EL COSTO DE MATENIMIENTO Y
OPERACION .

A= R*P' - M (US$/AÑO).
D: DEPRECIACION ANUAL DEL EQUIPO A LO LARGO DE LA VIDA UTIL ESTIMADA.

D = I/V (US$/AÑO).

PARAMETROS DE EVALUACION ECONOMICA DE PRIMER ORDEN:

A) RELACION (INVERSION/AHORRO) (PAYBACK)

X =I/A.

B) TASA DE RETORNO DE LA INVERSION (T.I.R.)

TIR = (A - D)/I*(100%)

ESTE PARAMETRO TIENE EN CUENTA LA VIDA UTIL ESTIMADA DEL EQUIPO A TRAVES
DE LA DEPRECIACION (D).
PARA JUSTIFICAR LA INVERSION , ES PRECISO QUE EL T.I.R. CORRESPONDIENTE AL
EQUIPO ANALIZADO SEA MAYOR QUE EL CORRESPONDIENTE A OTRAS ALTERNATIVAS
DE INVERSION TIPICAMENTE 15 A 20 % ).
ENERGETICA.

NECESARIOS

LARGO DE LA

HORRO DEBIDO
PO A TRAVES

NDIENTE AL
ALTERNATIVAS