Vous êtes sur la page 1sur 14

DESIGN CALCULATION FOR PROPOSED BRIDGE AT

RD: 6-7 RURRIALA MINOR.


1 Discharge = 19 Cs
2 Bed Level = 743.86
3 Full Supply Level = 745.66
4 N.S.L = 745.26
5 Bed Width (B) = 7.50
6 Full Supply Depth (FSD) = 1.80
7 W.S Slope = 0.26%o ft.
8 Free Board = 3.00
9 Scour Depth (D/2) = 0.9
10 ( But addopted as per C.D.O Drawing) = 1.75
B) DESIGN DATA OF BRIDGE
1 Description of Road = Village Road Bridge
2 Loading I.R.C = A-Class
3 Angle of Crossing = 90`
4 Thickness of Slab = 1.18 ft
5 Wearing Coat = 0.25
Proposed Road Level (FSL + Free
6 = 750.09
Board+Thickness of Slab+Wearing Coat).
7 Road Way = 14.00 ft.
8 Water Way = 9.50
9 No. of Spans = 1 No.
10 Width of spans = 9.5
11 Design of Slab = (As per CDO Drawing No. W-12)
12 Thickness of Slab = 1.18
13 Reinforcement
14 Main Bars 3/4" dia 4.5"C/C
15 Distribution Bars 1/2" dia 9.5"C/C
16 Type of Parapit = (As per CDO Drawing)
17 Length of Abutment =
(1.5+14+1.5) = 17
18 Section of Abutment = As per CDO Drawing No. W-12
19 Section of wing walls = As per CDO Drawing No. W-13
20 Length of wing walls =
1.5 (Road Level - Bed Level) - 1.5 = 7.84
Skew Length (Streight length x 1.1546) = 9.06
Say :- = 8.00
21 Foundation Under Abutments (5 height) =
22 Width of concrete = 5.20
23 Height of concrete = 2.00
24 Foundation under wing walls (7 height) =
25 Width of concrete = 4.20
26 Height of concrete = 2.00
Note= Other details are as per C.D.O Standard Design.

Sub Engineer Sub Divisional Officer Executive Engineer


Nandipur Section Gujranwala Sub Division UCC Gujranwala Division UCC
Gujranwala. Gujranwala
DESIGN CALCULATION FOR PROPOSED BRIDGE AT
RD: 4+500 RURRIALA MINOR.
1 Discharge = 19 Cs
2 Bed Level = 744.38
3 Full Supply Level = 746.18
4 N.S.L = 746.55
5 Bed Width (B) = 7.50
6 Full Supply Depth (FSD) = 1.80
7 W.S Slope = 0.26%o ft.
8 Free Board = 3.00
9 Scour Depth (D/2) = 0.9
10 ( But addopted as per C.D.O Drawing) = 1.75
B) DESIGN DATA OF BRIDGE
1 Description of Road = Village Road Bridge
2 Loading I.R.C = A-Class
3 Angle of Crossing = 90`
4 Thickness of Slab = 1.18 ft
5 Wearing Coat = 0.25
Proposed Road Level (FSL + Free
6 = 750.61
Board+Thickness of Slab+Wearing Coat).
7 Road Way = 14.00 ft.
8 Water Way = 9.50
9 No. of Spans = 1 No.
10 Width of spans = 9.5
11 Design of Slab = (As per CDO Drawing No. W-12)
12 Thickness of Slab = 1.18
13 Reinforcement
14 Main Bars 3/4" dia 4.5"C/C
15 Distribution Bars 1/2" dia 9.5"C/C
16 Type of Parapit = (As per CDO Drawing)
17 Length of Abutment =
(1.5+14+1.5) = 17
18 Section of Abutment = As per CDO Drawing No. W-12
19 Section of wing walls = As per CDO Drawing No. W-13
20 Length of wing walls =
1.5 (Road Level - Bed Level) - 1.5 = 7.84
Skew Length (Streight length x 1.1546) = 9.06
Say :- = 8.00
21 Foundation Under Abutments (5 height) =
22 Width of concrete = 5.20
23 Height of concrete = 2.00
24 Foundation under wing walls (7 height) =
25 Width of concrete = 4.20
26 Height of concrete = 2.00
Note= Other details are as per C.D.O Standard Design.

Sub Engineer Sub Divisional Officer Executive Engineer


Nandipur Section Gujranwala Sub Division UCC Gujranwala Division UCC
Gujranwala. Gujranwala
DESIGN CALCULATION FOR PROPOSED BRIDGE AT
RD: 8+925 ISSAN MINOR.
1 Discharge = 17 Cs
2 Bed Level = 665.14
3 Full Supply Level = 666.84
4 N.S.L = 665.16
5 Bed Width (B) = 7.00
6 Full Supply Depth (FSD) = 1.70
7 W.S Slope = 0.275%o ft.
8 Free Board = 1.50
9 Scour Depth (D/2) = 0.85
10 ( But addopted as per C.D.O Drawing) = 1.75
B) DESIGN DATA OF BRIDGE
1 Description of Road = Village Road Bridge
2 Loading I.R.C = A-Class
3 Angle of Crossing = 90`
4 Thickness of Slab = 1 ft
5 Wearing Coat = 0.25
Proposed Road Level (FSL + Free
6 = 669.59
Board+Thickness of Slab+Wearing Coat).
7 Road Way = 14.00 ft.
8 Water Way = 7.00
9 No. of Spans = 1 No.
10 Width of spans = 7
11 Design of Slab = (As per CDO Drawing No. W-12)
12 Thickness of Slab = 1
13 Reinforcement
14 Main Bars 1" dia 5.5"C/C
15 Distribution Bars 3/4" dia 10.5"C/C
16 Type of Parapit = (As per CDO Drawing)
17 Length of Abutment =
(1.5+14+1.5) = 17
18 Section of Abutment = As per CDO Drawing No. W-12
19 Section of wing walls = As per CDO Drawing No. W-13
20 Length of wing walls =
1.5 (Road Level - Bed Level) - 1.5 = 6.00
Skew Length (Streight length x 1.1546) = 6.90
Say :- = 7.00
21 Foundation Under Abutments (5 height) =
22 Width of concrete = 4.85
23 Height of concrete = 2.00
24 Foundation under wing walls (7 height) =
25 Width of concrete = 3.80
26 Height of concrete = 2.00
Note= Other details are as per C.D.O Standard Design.

Sub Engineer Sub Divisional Officer Executive Engineer


D.D.C Section Sikhanwala Sub Division UCC Gujranwala Division UCC
Sikhanwala. Gujranwala
DESIGN CALCULATION FOR PROPOSED BRIDGE AT
RD: 0+500 RURRIALA MINOR.
1 Discharge = 19 Cs
2 Bed Level = 745.42
3 Full Supply Level = 747.22
4 N.S.L = 748.1
5 Bed Width (B) = 7.50
6 Full Supply Depth (FSD) = 1.80
7 W.S Slope = 0.26%o ft.
8 Free Board = 3.00
9 Scour Depth (D/2) = 0.9
10 ( But addopted as per C.D.O Drawing) = 1.75
B) DESIGN DATA OF BRIDGE
1 Description of Road = Village Road Bridge
2 Loading I.R.C = A-Class
3 Angle of Crossing = 90`
4 Thickness of Slab = 1.18 ft
5 Wearing Coat = 0.25
Proposed Road Level (FSL + Free
6 = 751.65
Board+Thickness of Slab+Wearing Coat).
7 Road Way = 14.00 ft.
8 Water Way = 9.50
9 No. of Spans = 1 No.
10 Width of spans = 11
11 Design of Slab = (As per CDO Drawing No. W-12)
12 Thickness of Slab = 1.18
13 Reinforcement
14 Main Bars 3/4" dia 4.5"C/C
15 Distribution Bars 1/2" dia 9.5"C/C
16 Type of Parapit = (As per CDO Drawing)
17 Length of Abutment =
(1.5+14+1.5) = 17
18 Section of Abutment = As per CDO Drawing No. W-12
19 Section of wing walls = As per CDO Drawing No. W-13
20 Length of wing walls =
1.5 (Road Level - Bed Level) - 1.5 = 7.84
Skew Length (Streight length x 1.1546) = 9.06
Say :- = 8.00
21 Foundation Under Abutments (5 height) =
22 Width of concrete = 5.20
23 Height of concrete = 2.00
24 Foundation under wing walls (7 height) =
25 Width of concrete = 4.20
26 Height of concrete = 2.00
Note= Other details are as per C.D.O Standard Design.

Sub Engineer Sub Divisional Officer Executive Engineer


Nandipur Section Gujranwala Sub Division UCC Gujranwala Division UCC
Gujranwala. Gujranwala
DESIGN CALCULATION FOR PROPOSED BRIDGE AT
RD: 11+900 AIMA MINOR.
1 Discharge = 7.00 Cs
2 Bed Level = 743.81
3 Full Supply Level = 745.11
4 N.S.L = 742.65
5 Bed Width (B) = 2.35
6 Full Supply Depth (FSD) = 1.30
7 W.S Slope = 0.35%o ft.
8 Free Board = 1.00
9 Scour Depth (D/2) = 0.65
10 ( But addopted as per C.D.O Drawing) = 0.65
B) DESIGN DATA OF BRIDGE
1 Description of Road = Village Road Bridge
2 Loading I.R.C = A-Class
3 Angle of Crossing = 90`
4 Thickness of Slab = 1.18 (As per Highway standard design)
5 Wearing Coat = 0.25
Proposed Road Level (FSL + Free
6 = 747.54
Board+Thickness of Slab+Wearing Coat).
7 Road Way = 14.00 ft.
8 Water Way (B+D) = 3.65
9 No. of Spans = 2 No.
10 Width of spans = 11.2
11 Design of Slab = (As per Highway standard design)
12 Thickness of Slab = 1.18
13 Reinforcement
14 Main Bars 1" dia 6-1/2"C/C
15 Distribution Bars 3/4" dia 10-1/2"C/C
16 Type of Parapit = (As per Highway standard design)
17 Length of Abutment =
(1.5+14+1.5) = 17
18 Section of Abutment = As per CDO Drawing No. W-12& W-13
19 Section of wing walls = As per CDO Drawing No. W-13
20 Length of wing walls =
1.5 (Road Level - Bed Level) - 1.5 = 6.50
Skew Length (Streight length x 1.1546) = 7.50
Say :- = 7.50
21 Foundation Under Abutments (8 height) =
22 Width of concrete = 5.20
23 Height of concrete = 2.00
24 Foundation under wing walls =
25 Width of concrete = 4.20
26 Height of concrete = 2.00
Note= Other details are as per C.D.O Standard Design.

Sub Engineer Sub Divisional Officer Executive Engineer


Mehta Suja Section Muridke Sub Division UCC Gujranwala Division UCC
Muridke Gujranwala
DESIGN CALCULATION FOR PROPOSED BRIDGE AT
RD: 9+900 AIMA MINOR.
1 Discharge = 7.00 Cs
2 Bed Level = 743.81
3 Full Supply Level = 745.11
4 N.S.L = 742.65
5 Bed Width (B) = 2.35
6 Full Supply Depth (FSD) = 1.30
7 W.S Slope = 0.35%o ft.
8 Free Board = 1.00
9 Scour Depth (D/2) = 0.65
10 ( But addopted as per C.D.O Drawing) = 0.65
B) DESIGN DATA OF BRIDGE
1 Description of Road = Village Road Bridge
2 Loading I.R.C = A-Class
3 Angle of Crossing = 90`
4 Thickness of Slab = 1.18 (As per Highway standard design)
5 Wearing Coat = 0.25
Proposed Road Level (FSL + Free
6 = 747.54
Board+Thickness of Slab+Wearing Coat).
7 Road Way = 14.00 ft.
8 Water Way (B+D) = 3.65
9 No. of Spans = 2 No.
10 Width of spans = 11.2
11 Design of Slab = (As per Highway standard design)
12 Thickness of Slab = 1.18
13 Reinforcement
14 Main Bars 1" dia 6-1/2"C/C
15 Distribution Bars 3/4" dia 10-1/2"C/C
16 Type of Parapit = (As per Highway standard design)
17 Length of Abutment =
(1.5+14+1.5) = 17
18 Section of Abutment = As per CDO Drawing No. W-12& W-13
19 Section of wing walls = As per CDO Drawing No. W-13
20 Length of wing walls =
1.5 (Road Level - Bed Level) - 1.5 = 6.50
Skew Length (Streight length x 1.1546) = 7.50
Say :- = 7.50
21 Foundation Under Abutments (8 height) =
22 Width of concrete = 5.20
23 Height of concrete = 2.00
24 Foundation under wing walls =
25 Width of concrete = 4.20
26 Height of concrete = 2.00
Note= Other details are as per C.D.O Standard Design.

Sub Engineer Sub Divisional Officer Executive Engineer


Mehta Suja Section Muridke Sub Division UCC Gujranwala Division UCC
Muridke Gujranwala
DESIGN CALCULATION FOR PROPOSED BRIDGE AT
RD: 2+500 AIMA MINOR.
1 Discharge = 12.50 Cs
2 Bed Level = 746.00
3 Full Supply Level = 747.60
4 N.S.L = 746.44
5 Bed Width (B) = 3.00
6 Full Supply Depth (FSD) = 1.60
7 W.S Slope = 0.35%o ft.
8 Free Board = 1.00
9 Scour Depth (D/2) = 0.8
10 ( But addopted as per C.D.O Drawing) = 0.8
B) DESIGN DATA OF BRIDGE
1 Description of Road = Village Road Bridge
2 Loading I.R.C = A-Class
3 Angle of Crossing = 90`
4 Thickness of Slab = 1.18 (As per Highway standard design)
5 Wearing Coat = 0.25
Proposed Road Level (FSL + Free
6 = 750.03
Board+Thickness of Slab+Wearing Coat).
7 Road Way = 14.00 ft.
8 Water Way (B+D) = 4.60
9 No. of Spans = 2 No.
10 Width of spans = 11.2
11 Design of Slab = (As per Highway standard design)
12 Thickness of Slab = 1.18
13 Reinforcement
14 Main Bars 1" dia 6-1/2"C/C
15 Distribution Bars 3/4" dia 10-1/2"C/C
16 Type of Parapit = (As per Highway standard design)
17 Length of Abutment =
(1.5+14+1.5) = 17
18 Section of Abutment = As per CDO Drawing No. W-12& W-13
19 Section of wing walls = As per CDO Drawing No. W-13
20 Length of wing walls =
1.5 (Road Level - Bed Level) - 1.5 = 6.50
Skew Length (Streight length x 1.1546) = 7.50
Say :- = 7.50
21 Foundation Under Abutments (8 height) =
22 Width of concrete = 5.20
23 Height of concrete = 2.00
24 Foundation under wing walls =
25 Width of concrete = 4.20
26 Height of concrete = 2.00
Note= Other details are as per C.D.O Standard Design.

Sub Engineer Sub Divisional Officer Executive Engineer


Mehta Suja Section Muridke Sub Division UCC Gujranwala Division UCC
Muridke Gujranwala