Percentage of steel p 1.1 % yield strength of steel Fy 415 N/mm2 Tributary Area Length L 6 M Tributary Area Width B 5 M Floor Tributary area for col. Load A 30 m2 column length a 0.3 M column width b 0.3 M column height hc 4 M Beam width Wb 0.3 M Beam depth Db 0.5 M Beam total length of tributary Lb 21.4 M Thickness of slab ts 0.125 M Thickness of finish t 0.075 M Thickness of masonry tm 0.23 M Height of masonry hm 3.5 M Length of masonry Lm 21.4 M Unit weight of RCC y RCC 25 Kn/m3 Unit weight of Finish y FIN 25 Kn/m3 unit weight of masonry y B MAS 20 Kn/m3 Live load intensity IL int. 5 Kn/m2 CALCULATIONS Fy value col. Working capacity P= 0.6 fck + 0.77 (p/100) fy before 1990
self weight of slab 93.75 KN since 1990
Load from finish 56.25 KN Load from Masonry 167.44 KN Self weight of Beam 39 KN Self weight of column 9 KN Fck value Imposed (Live) load 150 KN before 2002 Total Load 515.44 KN since 2002 b) working stress in column 5.7271111111 N/mm2
a) col. Working capacity
P= 0.6 fck + 0.77 (p/100) fy 14.31505 N/mm2
Factor of Safety FOS 2.4995237079
FOS > 1.9 - no further action required
If 1.9> FOS>1.5 - SP2 action, min. yellow colour If 1.5> FOS>1.3 - SP1 action, min. Amber colour If 1.3> FOS-Priority 1 action, Mandatory red colour 250 N/mm2
415 N/mm2
10 N/mm2
18 N/mm2 DATA Symbol value units CALCULATIONS
Grade of concrete Fck 18 N/mm2 col. Working capacity
Percentage of steel p 1.18 % P= 0.6 fck + 0.77 (p/100) fy yield strength of steel Fy 415 N/mm2 Tributary Area Length L 5.17 M self weight of slab 111.478125 KN Tributary Area Width B 6.9 M Load from finish 66.886875 KN Floor Tributary area for col. Load A 35.673 m2 Load from Masonry 154.146 KN column length a 0.45 M Self weight of Beam 41.8875 KN column width b 0.45 M Self weight of column 17.71875 KN column height hc 3.5 M Imposed (Live) load 178.365 KN Beam width Wb 0.3 M Beam depth Db 0.5 M Total Load 570.48225 KN Beam total length of tributary Lb 23.24 M Thickness of slab ts 0.125 M b) working stress in column 2.8171962963 N/mm2 Thickness of finish t 0.075 M Thickness of masonry tm 0.23 M a) col. Working capacity Height of masonry hm 3 M P= 0.6 fck + 0.77 (p/100) fy 14.57069 N/mm2 Length of masonry Lm 23.24 M Unit weight of RCC y RCC 25 Kn/m3 Factor of Safety FOS 5.1720535126 Unit weight of Finish y FIN 25 Kn/m3 unit weight of masonry y B MAS 20 Kn/m3 FOS > 1.9 - no further action required Live load intensity IL int. 5 Kn/m2 If 1.9> FOS>1.5 - SP2 action, min. yellow colour If 1.5> FOS>1.3 - SP1 action, min. Amber colour If 1.3> FOS-Priority 1 action, Mandatory red colour Fy value