Vous êtes sur la page 1sur 1

Page: 13/13

NZT Engineer
Sheet: 1
Ian
RF-ALUMINUM ADM
1

Project: nztProject Model: Aluminium Sample Date: 3/31/2019


RF-ALUMINUM ADM
CA1
Design of aluminum 1.1 GENERAL DATA
members according to ADM Members to design: 1
Sets of members to design:

Standard: LRFD 2015

Ultimate Limit State Design


Load combinations to design: CO1 1.4D
CO2 1.2D
CO3 1.2D + 1.6L
CO4 1.2D + L

Serviceability Limit State Design


Load combinations to design: CO6 D
CO7 D+L

1.2 MATERIALS
Matl. Material E- Modulus Shear Modulus Poisson's Ratio Yield Stress Max. Thickness
No. Description E [kN/cm2] G [kN/cm2]  [-] fyk [kN/cm2] t [mm]
2 Aluminum 5083-H111-B221 6963.71 2620.01 0.330 0.00 76.2
(Extrusion) | ADM 2015

TO 200/100/3/3/3/3 1.3 CROSS-SECTIONS


Sect. Matl. Cross-Section Cross-Section Max Design
No. No. Description Type Ratio Comment
1 2 TO 200/100/3/3/3/3 Box welded 0.78

1.5 EFFECTIVE LENGTHS - MEMBERS


Member Buckli Length Buckling About Axis y Buckling About Axis z Lateral-Torsional and Flexural-Torsional Buck Member Type
No. Possib L [m] Possible Ky KyL[m] Possible Kz KzL[m] Possib K Lw [m] Lt [m] Me [kNm] Type y-y Type z-z
1 3.000 1.00 3.000 1.00 3.000 1.00 3.000 3.000 Eigenvalue

1.9 SERVICEABILITY DATA


Reference Length Precamber
No. Reference to Members/Sets No. Manually l [m] Direct. e0 [mm] Beam Type
1 Member 1 3.000 y, z 0.0 Beam

2.4 DESIGN BY MEMBER


Member Location LC/CO/ Design Design Description
No. x [m] RC No.
1 Cross-section No. 1 - TO 200/100/3/3/3/3
3.000 CO1 0.00 1 100) Negligible internal forces
0.000 CO3 0.78 1 105) Cross-section check - Bending about y-axis acc. to F
0.000 CO3 0.05 1 115) Cross-section check - Shear force in z-axis acc. to G
0.000 CO3 0.06 1 127) Cross-section check - Shear buckling acc. to G.2 or G.3 - Shear
force on z-axis
0.000 CO6 0.00 1 400) Serviceability - Negligible deflections
1.200 CO7 0.61 1 401) Serviceability - Deflection in z-direction - Beam