Académique Documents
Professionnel Documents
Culture Documents
- Homeland Security
- Nuclear Power Plants
- Oil, Gas and Mining Industries
- Industrial Safety
- Medical
- Environmental Monitoring
© 1992-2018 Polimaster
HOMELAND SECURITY
- Illicit Trafficking of Nuclear and
Radioactive Materials
- Emergency Response
- Mobile Monitoring
- Public Events Radiation Security
- Personal Safety and VIP Guards
© 1992-2018 Polimaster
Polimaster Solution
3 Localization
Emergency response
4 Identification
Personal safety
Personal
Radiation
Measurement and Localization Detectors
(PRD)
Gamma / Gamma-neutron
radiation monitors for:
•Vehicles
•Railway
•Cargo
•Pedestrians
Gamma / Gamma-
neutron
radiation monitors for:
•Vehicles
•Cargo
•Pedestrians
© 1992-2018 Polimaster
Radiation Portal Monitor РМ5000P series
• Pedestrians
• Luggage
© 1992-2018 Polimaster
PM5000P Application
Check point
Application in complex with metal detector
or at any enter/exit
© 1992-2018 Polimaster
PM5000P Application
Application for Luggage or Postage / Mail Room
Checking for Presence of Radioactive Material
© 1992-2018 Polimaster
Radiation Portal Monitors (RPM)
© 1992-2018 Polimaster
Measurement
and
Localization
© 1992-2018 Polimaster
Stages of Control (1)
Check the cargoes, pedestrians and vehicles for Radiation Portal Monitors
1 presence of any radioactive materials PM5000
© 1992-2018 Polimaster
Stages of Control (2,3)
Personal Radiation
Detectors (PRD)
Inspection method
PM1703MA-II PM1703GNA-II
PM1703MA-II BT PM1703GNA-II BT
The suppress NORM algorithm allows excluding alarm signals when the natural
gamma background value increases and Naturally Occurring Radioactive
Materials (NORM) are detected.
© 1992-2018 Polimaster
Personal Radiation Detectors
(PRD)
The new generation PRD with improved search algorithm and NORM
suppress function
Instruments are used for detection and
localization of gamma (PM1703MA-II)
and gamma-neutron (PM1703GNA-II)
radioactive sources and evaluate dose
equivalent rate (DER).
Suppress NORM implemented algorithm
allows excluding alarm signal when the
natural gamma background value
increases and Naturally Occurring
Radioactive Materials (NORM) are
detected.
• 1000 data points are stored in non-volatile
memory
• PC communication via USB and Bluetooth.
РМ1703MA-II Storing data format is designed to meet ANSI
PM1703GNA-II N42.42.
• Shockproof hermetic case IP65
• Easy-to-use, two-button operation
© 1992-2018 Polimaster
Personal Radiation Detector
PM1703MO-II BT
© 1992-2018 Polimaster
Multipurpose Radiation
Monitors/Identifier РМ1401К-3 series
Major features:
• All detectors build in a single metal body
(IP65)
• Binding of data to GPS coordinates
• Measurement of specific and volumetric
activity of 137Cs in the substances
© 1992-2018 Polimaster
Mobile monitoring /
Emergency
Response Systems
© 1992-2018 Polimaster
Mobile Detection System
PM6100
© 1992-2018 Polimaster
Personal
Safety
© 1992-2018 Polimaster
Electronic Personal Dosimeters
Personal
Dosimetry System
РМ1621 Series
PM1604 Series
© 1992-2018 Polimaster
Specific Items
for VIP Guards
© 1992-2018 Polimaster
Combined Chemical Agent
and Gamma Radiation Detector
PM2012M/PM2012MB
© 1992-2018 Polimaster
Contraband Detector PM2030
Functions
• Search for illegal objects
• Density indication of illegal object
• Formation of scanned objects library
• Search for gamma-radiation sources
• Data transfer to PC via USB
Features
• Surely detects hidden items by depth of scanning to 150 mm
• The device modular design for the scan unit application in
hard-to-reach places
• Telescopic extension pole for large objects examination
• Vibration alarm from the handle for invisible detection and
for work in noisy places
• Wireless sound alarm by Bluetooth 4.0
• Complies with the requirements of IAEA “Technical and
Functional Specification for Border Monitoring Equipment” in
gamma-radiation sources search mode
© 1992-2018 Polimaster
Networking
© 1992-2018 Polimaster
Centralized monitoring
and data acquisition
© 1992-2018 Polimaster
Command Center
Command center is deployed
at the headquarters of an
Authorized Agency
© 1992-2018 Polimaster