Vous êtes sur la page 1sur 12
Controllable Desuperheater Type 3994-0006-DK with pneumatic or electric actuator Edition: May 2007 we Desuperheaters are used to control the temperature of superheated steam {or gas). By injecting water into the steam flow, the steam temperature becomes reduced. Temperature reduction to 8° C (14° F) above the saturation temperature is possible. Features: ™ Characteristic: linear/modified parabolic ™ Large delta P water/steam possible (max 100 bar/1450 psi) ™ Large rangeability Tight shut-off No additional control valve required BO16-3EN ‘The nozzles in the sprayhead are designed to give the injection water a high velocity and a radial rotating movement under all conditions. The result isa fine atomisation and very quick evaporation (see fig. 2) Features of the DKV Desuperheater: ‘+ 3 types of control characteristics, for accurate Introduction Desuperheating (cooling) the steam can simply be achieved by inject water into the steam flow. When. injected, the water is evaporated by means of the