Vous êtes sur la page 1sur 6

Electrotherapy

Therapic 9400 - 9200 - 2000


2 and 4 channel electrotherapy equipment delivering low and medium frequency current 0476

Therapic 9400 with 4 independent channels

Wave forms

continuous
Galvanic interrupted
MF

monophase
diphase
sync. monophase
Diadynamic
sync. diphase
cp
lp

rectangular
Pulse triangular
trabert

rectangular
Therapic 9200
Faradic triangular
with 2 independent channels
neodynamic

burst form
Tens random
modulated

symmetric
Biphasic
asymmetric

quadripolar
isoplanar
Interential vectorial
bipolar
Therapic 2000 stimulating
with 2 independent channels russian current (kotz)

8
Therapic 8400 - 8200

Electrotherapy
0476 2 and 4 channel electrotherapy equipment delivering medium frequency currents

Therapic 8400 2 independent channels

Wave Forms

continuous
Galvanic interrupted
MF

rectangular
Pulse triangular
trabert

rectangular
Faradic triangular
neodynamic

burst
Tens random Therapic 8200 2 independent channels
modulated

quadripolar
isoplanar
vectorial
Interferential
bipolar
stimulating
russian current (Kotz)

9
Electrotherapy
Therapic 7400 - 7200 - 1500
2 and 4 channel electrotherapy equipment delivering low frequency currents 0476

Therapic 7400 4 independent channels

Wave forms:

continuous
Galvanic interrupted
MF

monophase
diphase
sync. monophase
Diadynamic
inc. diphase
cp
ip

rectangular
Pulse triangular
Therapic 7200 trabert
2 independent channels
rectangular
Faradic triangular
neodynamic

burst form
Tens random
modulated

symmetric
Biphasic
asymmetric

Therapic 1500
2 independent channels

10
Electrotherapy
Optional Accessories

ACC 610
urogynaecological kit comprising:
1 2 - ring vaginal probe
1 2 - ring anal-rectal probe
1 smart card where 30
work protocols are loaded for:
Stress urinary incontinence
Unstable detrusor urinary incontinence
Mixed urinary Incontinence (same patient has both ACC 610 - Urogynaecological kit
stress incontinence and urge incontinence)
Incontinence due to abnormality of urinary tracts
Urinary incontinence due to overflow
Reflex urinary incontinence
Overflow incontinence
Functional urinary incontinence
Night time enuresis (bed wetting)

ACC 501
Vocal Unit ACC 501 - Vocal Unit

ACC 051
Probe with activation button for manual stimulation
ACC 624
Cable link for connection to the Ultrasonic 1500 1300 -1100 - Us50 ultrasound device models (means that
electric current can be supplied with the ultrasound)

ACC 231
Complete galvanic basin kit comprising: 1 base 2 basins 2 electrodes

ACC 524
Smart card with fitness programmes

ACC 525
Smart card with cosmetic programmes

Accessories supplied 7200 - 8200 - 9200 7400 - 8400 - 9400 1500 - 2000

Power Cable 1 1 1
User’s manual 1 1 1
Fuses 2 da 315mA-T 2 da 315mA-T 2 da 1.6A-T
Electrodes 60x80 mm 4 8 4
Sponges for electrodes 60x80 mm 4 8 4
Electrodes 50x50 mm 4 8 4
Sponges for electrodes 50x50 mm 4 8 4
Eastic band 1000 mm 2 4 2
Elastic band 600 mm 2 4 2
11
Technical Specifications

Electrotherapy
Thanks to its advanced technology this device can now voltage and will signal any inconsistencies between
be continually updated and will be able to carry out the value entered and the value actually being
functions that become available in the future. supplied. It also ensures complete safety at all times.
By using a smart-card or an Internet connection, this
computer derived technology means that you can The system checks the wear and tear of the cables
easily update the unit by adding functions, protocols, and output electrodes and will signal when it is time to
and anything else our research and development replace them.
department makes available.
A useful encoder means that you can quickly select
The outputs are completely independent and mean that the current or the protocol to use by accessing a
different work protocols can be provided. library of over 100 programmes, or you can create
Each output module includes a microcontroller that and store up to 300 simple or sequential operational
carries out a real time check of the output current and protocols.

Technical features 7200 - 8200 - 9200 7400 - 8400 - 9400 1500 - 2000
Power Supply 230 Vca, 50-60Hz, ±10% 230 Vca, 50-60Hz, ±10% 230 Vca, 50-60Hz, ±10%

Maximum mains power absorption 30 VA 35 VA 30 VA

Double delay type (T) mains fuse 315mA-T 315mA-T 1.6A-T


protection
Backlit LCD display to view and check Graphics 320x240 DPI Graphics 320x240 DPI Alfanumeric 4x20 display
the operating parameters parametri

Programmable treatment time 1-99 minutes 1-99 minutes 1-99 minutes

Operation Constant Voltage Constant Voltage


Constand Current Constand Current Constant Current
Creation of the Rheobase and Chronaxie
intensity/Time curve
• •
Interferential Currents Up to 8.000 HZ Up to 8.000 HZ Up to 8.000 HZ

High Voltage Currents 500 V 500 V

Micro-currents • •
Ionphoresis direct currents Limited to 50 mA Limited to 50 mA Limited to 30 mA

Diadynamic currents Limited to 70 mA Limited to 70 mA Limited to 50 mA

Peak currents with other wave forms 140 mA 140 mA 100 mA

Peak Power 100 V 100 V 100 V

Independent output channels 2 4 2


Allarm “incorrect output load” • • •
Automatic and/or manual polarity inversion • •
Stored Protocols 100 100 1500: 16 - 2000: 32
Storable protocols in the internal memory 200 200 10
Storable I/T curve diagnose 100 100
Protocols in sequence that can be stored 10 10
Storable protocols in Smart Card 80 80
(50programs) (50 programs)
(20 I/T curve diagnose) (20 curve diagnose)
(10 protocols in sequence) (10 protocols in sequence)
Ultrasound Connection • • •
Vaccumed connection • • •
External connection of voice unit •
Software updates

Weight 4,4 Kg 5,2 Kg 4,3 Kg
Size 39x14x30 cm 39x14x30 cm 39x14x30 cm

12
Electrotherapy
Therapic Currents 7000 1500 8000 9000 2000
Isodynamic • •
Monophase • • • •
Diphase • • • •
Syncop. Monophase • • • •
Syncop. Dphfase • • • •
Short Period • • • •
Long Period • • • •
Rectangular • • • • •
Triangular • • • • •
Traebert • • • • •
Faradic rectangular • • • • •
Neodynamic Triang. • • • •
Neodynamic • • • • •
Tens • • • • •
Tens Random • • • • •
Tens Burst • • • • •
Biphasic Symmetric • •
Bphfasic Asymmetric • •
Ionophoresis • • • •
Iontophoresis • • • •
Russian Current • • •
IInterferential • • •
Classic Interferential • • •
Isoplanar Interferential • •
Vectorial Interferential • •
Stimulating • • •

Use of the equipment and stored programmes


Main effects of electrostimulation:

1. Training the neuromuscular system to respond appropriately during voluntary and involuntary exertion by
supplying active contraction (isometric, concentric, and eccentric) and consequent articular movement
which allows a proprioceptive feedback.
2. Modification of pain by the gate control mechanism or descending inhibition mechanisms (production of
endogenous opioids).
3. Control or reduction of spasticity through the stimulation of agonists (contraction-relaxation), antagonists
(reciprocal inhibition), or sensor motor inhibition.
4. Provides for the transdermic release of medicinal substances in the skin (iontophoresis).
5. Improves or maintains articular mobility by mechanical stretching of the muscles or connective tissue, or
reduces obstructions to movement caused by neuromuscular dysfunction (e.g. spasticity), pain, or oedema.
6. Favours the healing of wounds by increasing local circulation, creating a bactericide effect, or altering the
electric charge in the damaged area.
7. Delays or heals the oedema through muscular pump action or the effect of the electric charge on the
interstitial proteins (electric field phenomena).

Electrotherapy protocols:

Cervical pain Urge incontinence Phanthom limb pain


Carpal tunnel syndrome Cervical arthrosis Peripheral neuropathy
Shoulder pain Cervical brachialgia Trigeminus neuralgia
Lumbago Cervicalgia Shingles
Hip pain Dorsalgia Post herpetic neuralgia
Knee: repair surgery LCA Trapezius pain Temporomandibolar disfunction
Ankle surgery Fibromyalgia Gonalgia
Heel pain Intercostal Neuralgia Bicipital tendinitis
Chronic stress urinary incontinence Lumbago Lateral epicondylitis
Acute stress urinary incontinence Lumbar sciatica Medial epicondylitis

13