Product Specifications

RAAS FRM PM2.5/PM10 Sampler


RAAS2.5 - 100 Single Filter Sampler RAAS10 - 100 Single Filter Sampler
RAAS2.5 - 200 Audit Sampler RAAS10 - 200 Audit Sampler
RAAS2.5 - 300 Sequential Sampler RAAS10 - 300 Sequential Sampler

Overview The inlet provides a 10 micron


cut point that will function at a
Reference Ambient Air constant sampling rate inde-
Samplers (RAAS) are Federal pendent of wind speed and
Reference Method Samplers direction. The secondary size
specifically designed to comply selective element is the Well
with requirements of the Impactor Ninety-Six (WINS) that
National Ambient Air Quality further reduces the passed par-
Standards (NAAQS) for ticulate to exclude particles larg-
Particulate Matter (40 CFR Part er than 2.5 microns. The partic-
50). The standard requires a ulate is collected on a 47mm
fixed flow rate sampler, operat- PTFE filter.
ing at 16.67 liters/minute (one
cubic meter per hour), using a By providing the RAAS family of
specified inlet, tubing, second- products, Thermo can furnish a
ary size selective impactor, and solution to any particulate ambi-
filter holder. ent air sampling need.

Features

• Flexible and user friendly software guides you through system


set-up, event programming, calibration, and maintenance

• Flexible calibration of temperature sensors using either a thermo-


couple calibrator or submersion bath

• Stores over 16 days of 5-minute interval average data

• User settable interval for log data

• Stores up to 50 sample event summaries

• Multi-point calibration of all sensors for greater accuracy

• DataLink downloads all pertinent information from the field with


out cumbersome palmtops, PC’s or laptops

Analyze • Detect • Measure • ControlTM


General Specifications for RAAS2.5/10 100, 200, & 300 Systems

Environmental -30ºC to +45ºC 600mm


Hg to 800mm Hg, to 100% humidity, rain, and snow resistant.
Flow Rate 14 to 25 Lpm
a. Measurement Accuracy 2%
b. Resolution 0.01 liters/minute
c. Stability CV Less than 2%
Pressure Sensor (Barometric)
a. Accuracy 10mm Hg
b. Resolution 1mm Hg
Pressure Sensor (Meter Differential)
a. Accuracy 10mm Hg
b. Resolution 0.1mm Hg
Temperature Measurements (Ambient, Active Filter, Inactive Filter, Meter)
a. Max Error 2ºC
b. Resolution 0.1ºC
Ambient inaccuracy due to solar radiation: less than 1.6ºC at windspeed of 2 m/s.
Power Input
RAAS2.5 - 100 and RAAS2.5 - 300 / RAAS10 - 100 and RAAS10 - 300
a. 100-120 Volt, 50/60 Hz 3.0 amp max, 0.25 amp standby
b. 200-240 Volt, 50/60 Hz 1.5 amp max, 0.13 amp standby
RAAS2.5-200
a. 100-120 Volt, 50/60 Hz 1.0 amp max, 0.10 amp standby
b. 200-240 Volt, 50/60 Hz 0.5 amp max, 0.05 amp standby
Size
RAAS2.5 - 100 and RAAS2.5 - 300 / RAAS10 - 100 and RAAS10 - 300
a. Fully Assembled 75.5” H x 24” W x 18” D 192cm H x 61cm W x 46cm D
b. Base Unit 30.5” H x 16” W x 16” D 76cm H x 41cm W x 41cm D
c. Stand 21.0” H x 18” W x 18” D 53cm H x 46cm W x 46cm D
RAAS2.5 - 200 / RAAS10 - 200
a. Fully Assembled 73.5” H x 12” W x 12”D 187cm H x 30.5cm W x 30.5cm D
b. Flow Control Module 12.5” H x 9” W x 12” D 32cm H x 23cm x W x 30.5cm D
c. Filter Assembly 21.0” H x 9” W x 12” D 53cm H x 23cm x W x 30.5cm D
d. Stand Assembly 16.0” H x 12” W x 12” D 41cm H x 30.5cm W x 30.5cm D
Sampling
a. Number of Filter Positions RAAS2.5/10 - 100: One
RAAS2.5/10 - 200: One
RAAS2.5/10 - 300: Eight
b. Sampling Time 1 min to 99 hours, 99 minutes

RAAS2.5/10 Sampling Systems

The RAAS2.5 - 100 / RAAS10 - 100 series meets FRM (Federal Reference Method) standards for single day sampling. Gravimetric filter-
based with a single channel flow devise that produces a 24-hour concentration. This sampler will be used for the routine monitoring in
the SLAMS network, or any fence line monitoring program. US EPA Designation Number: RFPS-0598-119 (PM2.5) and RFPS-0699-130
(PM10).

The RAAS2.5 - 200 / RAAS10 - 200 is a standalone sampling system meeting the Federal Reference Method requirements for single fil-
ter PM2.5 sampling. It is designed to meet the portability requirements of an audit sampler. Also gravimetric filter based, this sampler
is designed to be transportable and capable of frequent sampling, and will be used to fulfill the requirement in the independent audit
program. US EPA Designation Number: RFPS-0299-128 (PM2.5) and RFPS-0699-131 (PM10).

The RAAS2.5 - 300 / RAAS10 - 300 series meets FRM standards for sequential day sampling. This gravimetric filter-based sampler can
automatically be set up for another 24-hour sample without operator assistance. US EPA Designation Number: RFPS-0598-120 (PM2.5)
and RFPS-0699-132 (PM10).

This specification sheet is for informational purposes only and is subject to change without notice. Thermo makes no warranties, expressed or implied, in this product
summary. © Copyright 2003 Thermo Electron Corporation. All rights reserved. Thermo Electron Corporation, Analyze.Detect.Measure.Control are trademarks of
Thermo Electron Corporation
Lit RAASMC304

Environmental Instruments 27 Forge Parkway Franklin, MA (866) 282-0430 toll free www.thermo.com/air
Air Quality Products 02038 (508) 520-0430
(508) 520-1460 fax

Vous aimerez peut-être aussi