AcroPrep™ Membrane-bottom
Filter Plates
Applications
Hydrophobic Membrane
(Solvent Based Solutions)
PTFE Membrane
Applications
• Molecular Synthesis Reactions
• Drug Synthesis Reactions
• Resin Cleavage Reactions
• Combi-chem Library Screening
• Sample Prep Involving Solvents
96 Well
350 µL 1 mL
Integrated Prefilter
Applications Applications
• Debris Removal • Plasmid Preparation
• Low Salt DNA Purification • Lysate Clearance
• Rapid Plasmid Preparation • Protein Solutions
• Proteinaceous Sample
Purification
• Tissue Homgenates
96 Well 96 Well
350 µL 350 µL 1 mL
GHP Membrane
(Hydrophilic Polypropylene)
Applications
• Cleavage Reactions
• In-gel Digestion
• Combi-chem Library Screening
• Drug Binding Studies
• Sample Prep
• Bead/Resin Applications
350 µL 1 mL 100 µL
PN 5045 Natural Housing White Housing Black Housing PN 5052 PN 5054 Short Tip Long Tip
No Prefilter
www.pall.com/lab
Plate Selection
Binding Media
Glass Fiber
Applications
• Receptor Ligand Binding Studies
• Cell-based Assays
• Sample Prep
• Gross Fractionation
350 µL 1 mL 100 µL
Natural Housing White Housing Long Tip Natural Housing White Housing
PN 5031, 5031L PN 5032 PN 5051
Short Tip Long Tip Short Tip Long Tip
PN 5073 PN 5072 PN 5073W PN 5072W
Membrane Chromatography
Mustang™ Membrane
Applications
• Fractionation of Proteins/Peptides
• Capture from Liquid Chromatography
• Antibody Purification
• Contaminant Removal Such as DNA, RNA,
or Other Charged Molecules
96 Well
350 µL 1 mL
Ultrafiltration
Polyethersulfone Membrane
(OmegaTM Membrane)
Applications
• Concentrate, Desalt, and Purify DNA, RNA,
Oligos, Proteins, and Peptides
• Size Exclusion Applications
• Clean-up of Labeling Reactions
• Determination of Free vs. Bound Drug in Plasma
• Purification of Nucleic Acids and Proteins
1 mL 350 µL 100 µL
Natural
(semi-opaque)
– fluorescence, TRF
White
(opaque)
– radioactivity,
chemiluminescence
Black
(opaque)
– lowest background for
fluorescence, TRF
www.pall.com/lab
Specifications
1. Place filter plate on vacuum manifold or hold the plate 2. Add sample and incubate. Apply vacuum.
so that the outlet tips are not touched.
3a. Release vacuum from the manifold. Remove filter plate OR 3b. Release vacuum from the manifold. Remove filter
and retained sample for further processing. plate. Remove collection (receiver) plate and utilize
collected filtrate in downstream applications.
www.pall.com/lab
Methodology (continued)
Vacuum Manifolds
• Pall Life Sciences • Porvair
• 3M • Qiagen, Inc.
• Innovative Microplates • Whatman
• Millipore
Performance
Figure 1
Lower Level of False Positives with AcroPrep 96 Filter Plates Than Competitive Plates
The serological immunoassays were performed with two manufacturer’s 96 well filter plates to compare Competitor M filter plates to Pall AcroPrep 96 filter
plates with 1.2 µm Supor® membrane. The serological immunoassays were performed using a single serum sample and three concentrations of rPhycoerythrin
conjugated antibody. The results from these filter plates were read with one Luminex LX100 Instrument. The results presented are for the sixteen individual
responses, the average, the standard deviation, and the percent coefficient of variation for the single serum sample. The Pall Life Sciences AcroPrep 96 filter
plates exhibit a lower level of false positive results than Competitor M filter plates.
Performance (continued)
Figure 2
AcroPrep™ 96 Filter Plates with Prefilter Speeds Sample Processing Times
12
5042
10 5046
COMP
Flow Rate (mL/sec)
0
100 µL 200 µL
Volume Filtered
The use of a prefilter shortens filtration times and allows greater flow rates
to be maintained at higher loads. Average flow rates for 100 and 200 µL
lysate samples were calculated for the AcroPrep 96 filter plate with Bio-Inert®
membrane (PN 5042), AcroPrep 96 filter plate with glass fiber over Bio-Inert
membrane (PN 5046), and Competitor hydrophilic PVDF plate (COMP). Error
bar indicates standard error (n = 8).
See Pall Corp. Technical Report PN 33308 for complete experimental details.
Figure 3
AcroPrep 96 UF Filter Plates Remove Salts While Maintaining High Sample Recoveries
In addition to desalting, ultrafiltration is also useful for the concentration of biomolecules. The efficiency of AcroPrep 96 UF filter plates with Omega™
membrane to remove salts and other small molecules is not at the expense of sample recovery. Using the AcroPrep 96 10K filter plate, recovery of ovalbumin
proteins were greater than 90% (n = 3) with salt removal efficiencies at greater than 95%. Using BSA and a 30K MWCO membrane, similiar results were
observed. A representative experiment is shown.
See Pall Corp. Technical Report PN 33309 for complete experimental details.
www.pall.com/lab
Ordering Information
AcroPrep™ 96 Filter Plates, 350 µL well AcroPrep 384 Filter Plates, 100 µL well
Part Number Description Pkg Part Number Description Pkg
5033 3K Omega™ membrane, natural 10/pack 5076 10K Omega membrane, long tips, natural 10/pack
5034 10K Omega membrane, natural 10/pack 5077 10K Omega membrane, short tips, natural 10/pack
5035 30K Omega membrane, natural 10/pack 5078 30K Omega membrane, long tips, natural 10/pack
5036 100K Omega membrane, natural 10/pack 5079 30K Omega membrane, short tips, natural 10/pack
5045 0.2 µm GHP membrane, natural 10/pack 5080 100K Omega membrane, long tips, natural 10/pack
5030 0.45 µm GHP membrane, natural 10/pack 5081 100K Omega membrane, short tips, natural 10/pack
5043 0.45 µm GHP membrane, white 10/pack 5070 0.45 µm GHP membrane, long tips, natural 10/pack
5044 0.45 µm GHP membrane, black 10/pack 5071 0.45 µm GHP membrane, short tips, natural 10/pack
5072 1.0 µm glass fiber media, long tips, natural 10/pack
5037 0.2 µm PTFE membrane, natural †† 10/pack
5072W 1.0 µm glass fiber media, long tips, white 10/pack
5038 0.45 µm PTFE membrane, natural †† 10/pack
5073 1.0 µm glass fiber media, short tips, natural 10/pack
5042 0.2 µm Bio-Inert® membrane, natural 10/pack
5073W 1.0 µm glass fiber media, short tips, white 10/pack
5046 3.0 µm glass fiber media/0.2 µm Bio-Inert 10/pack
membrane, natural 5084 1.2 µm Supor membrane, long tips, natural 10/pack
5031 1.0 µm glass fiber, natural † 10/pack 5085 1.2 µm Supor membrane, short tips, natural 10/pack
5031L 1.0 µm glass fiber, natural †, with lid 10/pack
† Glass Fiber plates have polypropylene support
5032 1.0 µm glass fiber, white † 10/pack
†† PTFE plates have polyester support
5029 0.45 µm Supor® membrane, natural 10/pack
5039 1.2 µm Supor membrane, natural 10/pack Vacuum Manifold
5039L 1.2 µm Supor membrane, natural, with lid 10/pack
Part Number Description Pkg
5041 Prefilter material/1.2 µm Supor membrane, 10/pack
natural 5017 Multi-well plate vacuum manifold 1/pkg
5047 Mustang™ Q ion exchange membrane, natural 10/pack 5014 1 mL receiver plate spacer block 1/pkg
5048 Mustang S ion exchange membrane, natural 10/pack 5015 350 µL receiver plate spacer block 1/pkg
7267 30-40 µm screen, natural 10/pack 5016 Replacement accessory kit 1/pkg
(includes O-ring, gasket and allen wrench)
• Centrifugal devices for nucleic acid and protein sample • BioTrace™, Biodyne,® and FluoroTrans® Transfer
preparation in the following sample volumes: Membranes offer precise performance and compatibility
Device Sample Volume with nearly every detection system available.
Nanosep® Device up to 0.50 mL
• AcroWell™ 96 Filter Plates are an excellent platform for
Microsep™ Device 0.5 to 3.5 mL
a wide variety of molecular biology detection
Macrosep® Device 3 to 15 mL
applications.
Jumbosep™ Device 15 to 60 mL
• Pall Chromatography Resins for the purification of
• Nanosep MF (microfiltration) Centrifugal Devices
biomolecules and compounds.
are available with Bio-Inert or GHP membranes for low
protein binding and high recoveries in applications such • Enchant™ Protein Purification Kits expedite
as particulate removal prior to sample analysis (GHP proteomic sample prep.
product is HPLC grade) and removal of precipitates.
References
www.pall.com/lab
Australia – Cheltenham, VIC India – Mumbai South Africa –
Tel: 03 9584 8100 Tel: 91 (0) 22 55995555 Johannesburg
1800 635 082 (in Australia) Fax: 91(0) 22 55995556 Tel: +27-11-2662300
Fax: 1800 228 825 Italy – Milano Fax: +27-11-3253243
Austria – Wien Tel: 02 47 79 61 Spain – Madrid
Tel: 00 1 49 192 0 Fax: 02-47796 394 Tel: 91-657-9876
Fax: 00 1 49 192 400 or 02-4122 985 Fax: 91-657-9836
Canada – Ontario Japan – Tokyo Sweden – Lund
Pall Life Sciences Tel: 905-542-0330 Tel: 03-6901-5800 Tel: (0)46 158400
600 South Wagner Road 800-263-5910 (in Canada) Fax: 03-5322-2134 Fax: (0)46 320781
Fax: 905-542-0331 Korea – Seoul Switzerland – Basel
Ann Arbor, MI 48103-9019 USA
Canada – Québec Tel: 82-2-560-7871 Tel: 061-638 39 00
Tel: 514-332-7255 Fax: 82-2-560-7822 Fax: 061-638 39 40
800.521.1520 (USA and Canada) 800-435-6268 (in Canada) Malaysia – Selangor Taiwan – Taipei
(+)800.PALL.LIFE (Outside USA and Canada) Fax: 514-332-0996 Tel: +60 3 5569 4892 Tel: 886 2 2545 5991
800-808-6268 (in Canada) Fax: +60 3 5569 4896 Fax: 886 2 2545 5990
734.665.0651 phone China – P. R., Beijing Poland – Warszawa Thailand – Bangkok
734.913.6114 fax Tel: 86-10-8458 4010 Tel: 22 510 2100 Tel: 66 2937 1055
Fax: 86-10-8458 4001 Fax: 22 510 2101 Fax: 66 2937 1066
France – St. Germain-en-Laye Russia – Moscow United Kingdom –
Tel: 01 30 61 39 92 Tel: 5 01 787 76 14 Farlington
Fax: 01 30 61 58 01 Fax: 5 01 787 76 15 Tel: 02392 302600
Lab-FR@pall.com Singapore Fax: 02392 302601
Germany – Dreieich Tel: (65) 389-6500 Lab-UK@europe.pall.com
Tel: 06103-307 333 Fax: (65) 389-6501
Fax: 06103-307 399
Lab-DE@pall.com