DETAILS OF STRUCURAL STEEL SECTIONS
1
SR. NO. INDEX NUMBER SECTION PROPERTY DETAILS
1
276 1
1 1
2 500
1 1 RHS 96X48X4.8
purlin size RHS 96x48x4.0 580 2

1 1 1
1
1000 2 2 RHS 122X61X5.4
1 1
3 3 RHS 50X25X2
1 2 2 500
1 1
1

475
2 2
1470 1470 3

2940 2562

2 2 475
5880
3

2 2 475

2828 475
2 2
3

2 2 475

12mm thk. stiffner plate


2 475
2
200 1

RCC Pedestal size 230x1170


CONC. GRADE M20
12Nos. 12# Vertical Bars
10# stirrups @250 c/c 1170

1865

RCC footing 1230x2120


CONC. GRADE M20

300

100

2120
CONSTRUCTION NOTES:-
1) FOR RCC RELATED CONSTRUCTION WORK, REFER IS 456 AND RELATED STANDARDS.
2320
2) CONTRACTOR SHOULD TAKE CARE OF TEMPORARY SUPPORTS AT HIS RESPONSIBILITY.STRUCTURAL ENGINEER
WILL NOT BE RESPONSIBLE FOR ANY ACCIDENTS RELATED TO ERECTION AND INSTALLATION.
3) IT IS ASSUMED THAT ALL THE REQUIRED IS STANDARDS AND RELATED SPECIFICATIONS FROM CONCERNED
REGULATORY AUTHORITIES HAVE BEEN TAKEN CARE BY SUPPLIER,CONTRACTOR AND MANUFACTURER RELATED
TO MATERIALS TO BE USED AND THE METHODS TO BE USED THEREOF IN THE CONSTRUCTION PROCESS.
4) ALL STRUCTURAL STEEL USED IN CONSTRUCTION SHOULD CONFIRM TO IS 2062 BEFORE FABRICATION.
5) GRADE OF STEEL SHOULD BE E250 (Fe 410W) OR DISCRIBED IN DRAWING OR DETAILS.
6) ASSUMED GRADE OF CONCRETE FOR FOUNDATION IS M:30.
7) ALL DIMENSIONS ARE IN MM AND LEVELS ARE IN METER. UNLESS OTHERWISE NOTED (U.N.O).
8) CONTRACTOR/OWNER SHOULD VARIFY THE LAYOUT PLAN.
9) IT IS INFORMED THAT NO ALTERATION IN MATERIAL/DESIGN/CONSTRUTION TO BE DONE WITHOUT BROUGHT
purlin size RHS 96x48x4.0 IN THE NOTICE TO STRUCTURAL CONSULTANT. INCASE OF ALTERATION WITHOUT NOTICE STRUCTURAL CONSULTANT
purlin size RHS 96x48x4.0 WILL NOT BE RESPONSIBLE FOR THE CONSEQUENCES THEREAFTER..
10) ANCHOR BOLTS MUST CONFIRM TO IS 5624-1993.
1 11) REQUIREMENT OF WELDS AND WELDING SHALL CONFORM TO IS 816 AND IS 9595, AS APPROPRIATE.
12) ALL WELDS TO BE ALL AROUND AND SHOULD HAVE 6mm UNLESS OTHER WISE NOTED (U.N.O).
13) DETAILS SHOWN IN THE CONNECTION DETAIL DRAWINGS SHOULD BE CONSIDERED AS THE
1 FINAL.DETAILSYSTEM DRAWINGS SHOULD NOT BE REFERRED FOR CONNECTION DETAIL.
1 1
276 1 14) MATERIAL, TESTING,INSPECTION AND EXECUTION OF RCC SHOULD BE AS PER IS 456.
purlin size RHS 96x48x4.0 580 2
15) ALL CONCRETE MIX WILL BE M25 UNLESS OTHERWISE MENTION.
1 16) ALL CONCRETE SHALL BE MACHINE MIXED AND MACHINE VIBRATED.
1 1 1 1000 17) #- INDICATES TMT BARS Fe415 GRADE CONFIRMING TO I.S. 1786-LATEST REVISION.
1 1 18) CLEAR COVER TO MAIN STEEL 50mm IN FOOTING, 40mm IN COLUMN, 25mm IN BEAM, 15mm IN SLAB.
19) MINIMUM LAP LENGTH SHOULD BE 50 TIMES BAR DIAMETER
1 2
1 1 REV. DATE DETAILS CKD PROJECT:-
1
AIRPORT AUTHORITY OF INDIA
CLIENT/CONTRACTOR:-
1 MR. CHETAN H. SHAH/MR. DEVESH SHAH(9426062288)
TITLE:-
CAR PARKING SHED
2
1470 1470 3 SCALE: N.T.S. ARCHITECT DEVAM CIVIL &
2940 2562
DATE:- 30/03/2019
STRUCTURAL
5880
2 DRAWN: HARSH
PROJECT NO. EME19S01 SERVICES PVT. LTD.
CKD : S.D.R
3 BASEMENT OF HIRANYA COMPLEX,OPP. ICICI BANK,
APPRD : S.D.R.
DWG. NO.:- ST-01 A3 R0 NEAR VASTRAPUR LAKE, AHMEDABAD,GUJARAT.PIN-380052