Vous êtes sur la page 1sur 15

Flow & Pressure Measurement equipment

Apex Instruments offers a variety of Flow, Pressure and Temperature measurement equipment to meet US EPA Method 2
sampling criteria.

We offer our automated Accu-Flow and the manual 3D flow measurement systems as well as pitot tubes, modular pitots,
standard pitots, cam-locks, flanges, port adapters and packing glands.

Additionally, we carry data loggers, liquid manometers, hand held digital


manometers, air velocity kits, magnahelic gauges, anemometers, pressure
and temperature transducers/transmitters and supporting accessories.

US EPA Method 1 specifies an appropriate sampling location for


conducting velocity traverse. The sampling locations must meet certain
criteria to be valid such as duct diameter, displacement from flow
disturbances, and laminar flow conditions.

US EPA Method 2 is performed to determine the average stack gas velocity from measurement of the
gas density and average velocity head using Type “S” (Stausscheibe or reverse type) pitot tube. Apex Instruments
manufactures and guarantees Type “S” pitot tubes in accordance with the Method 2 design specifications. However,
calibration is available with purchase of pitot tubes. Apex Instruments offers calibration equipment and services. A variety
of materials, sizes and configurations are available. The most common are constructed from either 1/4 inch or 3/8 inch
OD Stainless Steel or Alloy 600 tubing.

Inclinometers

Accu-Flow Pitots Accessories

www.apexinst.com
January 29,
Date Published: 2016
1/29/2018
FLOW MEASUREMENT EQUIPMENT

ACCU-FLOW MEASUREMENT SYSTEM


The Apex Accu-Flow Measurement System is configured to use a standard S-Type pitot, a two-dimensional 3 hole prism-
shaped probe or a three-dimensional 5 hole prism-shaped probe to accurately measure angular non-axial flow rates for
Methods 2, 2F and 2G. This system provides a way for testers to improve the measurement of volumetric flow rate under
cyclonic flow conditions found in some stacks and ducts. Multiple probes reduce the time for the flow Audits, therefore
saving money by not operating at undesirable loads. Oversized sensor ports reduce plugging. The 1/4” pressure lines have
quicker response and are less likely to leak than standard 1/8” lines.
Probe Interface
Module
AF-POD-5
Brass Bushing Flange
(Bored) PG-32S
32M/32F-B

Pitot Extension
4”/ 6” Flange Adapter 32PTX-o
with 12” Extension Specify Length
PF46XT32S
Comm Cable
AF-SC-o
Specify Length Accu-Flow
Software
Pod Interface
2-D Pitot Module
2DPT2 AF-PM1

Key Advantage for the Tester: Key Features:


1.) Easy to use, rotate-to-null and record 1.) All sensors are enclosed within
Key Advantage for the Source: the yaw angle and P the Pod enclosure
2.) Variant of EPA Method 2 2.) Pod is securely mounted
1.) Reduce operating costs 3.) Simple calibration, similar to S-Type directly to the probe extension
2.) Operate at more desirable loads 4.) Automated calculations and data records 3.) Results are immediate, stable
3.) Report lower emission 5.) Easy-to-use intuitive software for and accurate
4.) Save time by using automated system your laptop 4.) Larger pitot ports reduce
6.) Decrease test time and potential plugging
minimize errors 5.) 1/4” PTFE pressure lines
provide rapid response rates
versus standard 1/8” lines.

Apex Accu-Flow will save time and money as well as provide more accurate certifiable results.

2 INTERNET: WWW.APEXINST.COM PHONE: 800-882-3214 / 919-557-7300


FLOW MEASUREMENT EQUIPMENT

Easy-To-Use, Intuitive Software PROTRACTOR / INCLINOMETER


The operation software, hosted on a portable The M5C-4 Protractor/Inclinometer is an ideal tool
laptop computer, will allow the user to perform for measuring cyclonic yaw angles in accordance
Method 2G (2-D) testing.
with Method 2. The machined aluminum frame and
Software includes: integral baseplate provide a light, rigid and ultra-
• Number of probes used precise platform allowing the state-of-the-art sensor
• Number of ports to provide unsurpassed accuracy throughout the 360°
• Total number of traverse points to be sampled range. The inclinometer can be securely attached to a
• Record differential pressure, flow yaw angle,
probe with one of the following mounting brackets.
stack temperature, static pressure and M5C-4
barometric pressure. Accu-Flow Software
(Included in 2G-Pod)

Probe Interface Module


Method 2G POD Contains 2 x
5” Pressure Transducers,1 x 10”
Pressure Transducer, 1 Digital
Inclinometer, Type K TC Transmitter,
Barometric Pressure Sensor plus
Umbilical Connector, 2” Tube Clamp, Bracket for M5C-4 with 2” Aluminum Clamp.
5 Barb Connectors, 1 TC Jack.
M5C-4-32
AF-POD-5
Mounting Brackets for M5C-4
Bracket for M5C-4 with 1” Aluminum Clamp.
Pod Interface Module M5C-4-16

AF-PM1

2-D Calibration
Apex Instruments 2-D Pitot Tube must be calibrated before Optional Accessories:
initial use. Recalibration is also required either within 12 Magnehelic Bracket:
months of its first field use or after 10 field tests, whichever
Magnehelic Mounting Bracket.
occurs later. Additionally the 2D pitot shall be recalibrated
before it is used again. Method 2G, 2-D Pitot Calibration MAG-2D-BK
(Wind Tunnel), 60 and 90 fps, yaw angle offset determination.
PT-CAL-W2G □□ Magnehelic Gauge:
Magnehelic Gauge, +-.5 INWC Differential.
MAG-2301

SAMPLE METHOD 2G FLOW MODULAR SYSTEM COMPONENTS


Product Description
2DPT2 2-D Pitot, 2 hole prism-shaped tip with 1’ sheath supplied with Type K thermocouple, 1/4” tube unions, 34” Long.

PT-CAL-W2G□□ Method 2G, 2-D pitot calibration (wind tunnel), Specify Velocities, Yaw Angle Offsets determination.

32PTX-6 2-D Pitot Extension, 6’, 2” diameter sheath, split collar clamp with 1” ID.
32PTX-8 2-D Pitot Extension, 8’, 2” diameter sheath, split collar clamp with 1” ID.
AF-SC-30 30’ 2G cable with 7 pin, circular connectors.
AF-SC-60 60’ 2G cable 7 pin, circular connectors.
AF-SC-90 90’ 2G cable 7 pin, circular connectors.
AF-POD-5 Method 2G POD Contains 2 x 5” Pressure Transducers,1 x 10” Pressure Transducer, 1 Digital Inclinometer, Type K TC Transitter, Barometric
Pressure Sensor plus Umbilical Connector, 2” Tube Clamp, 5 Barb Connectors, 1 TC Jack. Also includes Accu-Flow Software, Connects to
laptop via USB, AF-POD-5 power and transmits data over current-loop connection.
AF-PM1 Single POD Interface Module contains USB HUB and current-loop transmitter for connecting AF-POD-5 to a single laptop.

EMAIL: INFO@APEXINST.COM INTERNET: WWW.APEXINST.COM 3


FLOW MEASUREMENT EQUIPMENT

3-D FLOW MEASUREMENT CONSOLE


The Apex Instruments XC-3D55 3-D Flow Measurement Console is used in
conjunction with various pitots to determine velocity pressure, yaw angle and pitch
angle of the flow velocity vector in a stack or duct according to U.S. EPA Method
2, 2F or 2G (the determination of stack gas velocity and volumetric flow rate with
three-dimensional probes).

The XC-3D55 console easily interfaces with the UINC-3D- Umbilical/Inclinometer


Assembly through a series of 1/4” quick connects, a 4-pin circular connector and a
Type K Thermocouple jack. Readings for Stack Temperature, Velocity Pressure,
Pitch Pressure and Yaw Angle are displayed respectively through a display,
process meters and a totalizer. The Null Angle is displayed through a Magnehelic.
XC-3D55

Meter Console Specifications (XC-3D55):


Stack Temperature: Type-K Thermocouple.
Velocity Pressure: (P1-P2) Range ±5” H2O.
Yaw Null: Bidirectional (P2-P3) Range ±5” H2O 5 Bi.
Pitch Range: Bidirectional (P4-P5) Range ±5” H2O 5 Bi.
Yaw Angle Range: 180° (static >360°). +/-.01°
Breaker Switch: Magnetic Type Circuit Breaker Rocker Switch

METHOD 2F 3D SYSTEM

PG-32S Packing Gland

3DPT2 32M/32F-B 32PTX-


5 Hole Pitot with 2 FT. Brass Bushing Probe Extension UINC-3D-
Sheath (Bored) Inclinometer Pod
with Integrated
PF-46XT32S Umbilical
Universal Port Flange
w/ Extension

METHOD 2F
XC-3D55 Console
3-D FLOW MODULAR SYSTEM COMPONENTS
Product Description
XC-3D55 Digital 3-D Flow Measurement Console Digital Displays for temperature, velocity pressure, pitch pressure, yaw angle
3DPT2 3-D Pitot, 5 hole prism-shaped tip with 2’ sheath supplied with five 1/8” to 1/4” tube unions
32PTX-  Probe Extension, 2” Diameter Sheath, Split Collar Clamp with 1” ID, Specify Length
PF-46XT32S Port Flange with Extension, Flange Fits, 4 & 6 Inch Ports
32M/32B-B 2 in. Bored Brass Bushing, 2 in. MNPT with 2.035 in. Bore
PG-32S 2 in. Packing Gland, SS Body & Nut, 2 In. MNPT, PTFE ferrule included
PT-CAL-W2F   3-D Pitot Calibration (Wind Tunnel), Specifiy Pitch Angles and Velocities
UINC-3D-  3-D Inclinometer Pod and Umbilical Cord, Specity Umbilical Cord Length in Feet
U-PTX-      2 in. Dia. Pitot Sheath Extension, See Legend above for Specifics
AK-M2 Audit Kit

4 INTERNET: WWW.APEXINST.COM PHONE: 800-882-3214 / 919-557-7300


FLOW MEASUREMENT EQUIPMENT

PITOT TUBES
Type-S Pitot Tubes are used to measure gas veloci-
ties. When the pitot is faced into the gas stream, the
pressure difference between the two ports can be
used to calculate the velocity pressure. This differential
velocity pressure is measured with liquid manometers
or electronic pressure transducers.
Baseline coefficient value is 0.84. Wind tunnel
calibration services are available upon request.

U.S. EPA Method 1 specifies appropriate sampling


locations for conducting a velocity or particulate
traverse. The sampling locations must meet certain
criteria to be valid. (ie., duct diameter and the sam-
pling location, relative to flow disturbance locations to
ensure laminar, non-cyclonic, flow in the stack.)
Apex Instruments manufactures Type-S pitot tubes in
accordance with the Method 2 design specifications. A
wide variety of materials, sizes and configurations are
available. The most common are constructed from ei-
ther 1/4” or 3/8” OD stainless steel or Alloy 600 tubing.

Type-S Pitot Tube Design Advantages:


• Large openings resist plugging
• Compact design fits easily in sampling ports.
• Maintains calibration in harsh environments.
• Suitable for determining cyclonic flow
• Suitable for measuring yaw-angle of the velocity vector
• Economically priced

Type-S Pitot Disadvantages:


• Reads high
• Potential for misalignment

EMAIL: INFO@APEXINST.COM INTERNET: WWW.APEXINST.COM 5


FLOW MEASUREMENT EQUIPMENT

MODULAR PITOTS

MODULAR PITOT COMPONENTS - EXTENSIONS


Purchase Separately

STAINLESS STEEL UNIONS AND QUICK CONNECTS


Product Description
Product Description
MPT-6-181 181 mm Tip
modified with 4SC4-S Stainless Steel Tube Union, 1/4”
TC Retainer 4TUR6-S Stainless Steel tube end reducer; 3/8” tube
PTB-3 3’ Body union to 1/4” tube stub
PTE-2 2’ Extension 6RU4-S Stainless Steel reducing tube union; 3/8”
to 1/4”
PTE-3 3’ Extension
6SC6-S Stainless Steel tube union, 3/8”
PTE-4 4’ Extension
QC-M4-SS 1/4” Quick Connects
QC-M6-SS 3/8” Quick Connects
Order unions and quick connects separately

MODULAR PITOT COMPONENTS - PITOT TIPS

Product Description
MPT-6-181-OFF Replacement Pitot Tip, 3/8",SS, Offset for use w/ 47mm Filter holder & PM2.5 Cyclone **
MPT-6-181-OFF-WC Replacement Pitot Tip, 3/8",SS, Offset for use w/ 47mm Filter holder& PM2.5 Cyclone **
MPT-6-181 Replacement Pitot Tip for Standard Method 5 Probe Assemblies, 181 mm in length **
MPT-6-225-OFF Offset Replacement Pitot Tip, 3/8", SS, Ext., for use w/ method 5 nozzle & SFA-47 in-stack filter **
MPT-6-255-OFF Offset Extended Pitot Tip for PM10 Cyclone with 47 mm Filter Assembly **
MPT-6-255-OFF-WC Offset Extended Pitot Tip for PM10 Cyclone with 47 mm Filter Assembly **
MPT-6-320 Replacement Pitot Tip, 3/8", S.S.,Ext., for use w/ standard method 5 nozzle & SFA-190, SFA-300, or SFA-2590 In-Stack
Filters **
MPT-6-320-OFF Offset Replacement Pitot Tip, 3/8", S.S.,Extended for use w/ standard method 5 nozzle and SFA-190, SFA-300, or SFA-
2590 In-Stack F **
MPT-6-425 Replacement Pitot Tip,3/8",SS, extended for use w/ PM10 Cyclone & 47mm In-Stack Filter **
MPT-6-425-OFF Offset Replacement Pitot Tip, 3/8",SS, Offset for use with 47mm Filter holder and PM2.5-10 Cyclone Combo Kit **
MPT-6-425-OFF-WC Offset Replacement Pitot Tip, 3/8",SS, Offset for use with 47mm Filter holder and PM2.5-10 Cyclone Combo Kit ***

** Includes Geometric Pitot Calibrations


** Includes Geometric Pitot Calibration and Wind Calibration

6 INTERNET: WWW.APEXINST.COM PHONE: 800-882-3214 / 919-557-7300


FLOW MEASUREMENT EQUIPMENT

PITOT TUBE EXTENSIONS


TELESCOPIC TYPE “S” PITOT

Apex Instruments Telescoping Pitot Probe allows the versatility of travers-


ing larger stacks with optional telescoping ranges while providing the ability to
package this probe in a more compact container. The design incorporates a
pitot tube with 1” OD oversheath connected to a 2” OD extension with adjust-
able clamp. Rigid or flexible tubing connections are available. 1/4” ID PTFE
with stainless steel overbraid is recommended. PFA or glass insulated Type-K
thermocouples with overbraid are available.

Varying pitot tube lengths are available. Please call for details.

U-PTX     

Specify:
Length in Feet
Number of Sample Lines
Tubing Material
Thermocouple Extension Type
Quick Connect Size

EMAIL: INFO@APEXINST.COM INTERNET: WWW.APEXINST.COM 7


FLOW MEASUREMENT EQUIPMENT

STANDARD PITOT TUBE FOR METHOD 2C


This Pitot tube is custom made to specifications outlined in US
EPA Method 2C. Modified hemispherical-nosed pitot of Method 2C
features a shortened stem and enlarged impact and static pres-
sure holes. This pitot is useful for saturated gas streams when
“back-purging” is ineffective. Pitot coefficient: 0.99 unless wind
tunnel calibrated.

STAINLESS STEEL PITOT


Product Length
PT2C-24 24”
PT2C-36 36”
PT2C-48 48”
PT2C- -
PT2C-60 60”
Length (ft.)

Oversheath Option
16 = 1” Oversheath (Recommended with any probe over 6’)
32 = 2” Oversheath (Recommended with andy probe over 12’)

2-DIMENSIONAL PROBE (3-HOLE PITOT)


The Apex Instruments 2-Dimensional Probe is used in Method
2G for measuring the velocity pressure and the yaw angle of the
flow velocity vector in a stack or duct using measurements and
a determination of the stack gas density, the average near-axial
velocity of the stack gas is calculated. The rear-axial velocity of
the stack gas accounts for the yaw, but not the pitch component
of flow. The average gas volumetric flow rate in the stack or duct
is then determined from the average near-axial velocity. The
Inclinometer is used for determination of the calibrated yaw offset.
The pitot is designed to be inserted into our 2 inch diameter probe
extension. The pitot tube must be calibrated in accordance with
Method 2G prior to use.

2DPT2

3-D PITOT (5-HOLE PITOT)


The Apex Instruments 3-D Pitot is capable of measuring yaw and
pitch of nonuniform flows. The yaw angle is determined directly
by rotating the pitot to null the pressure across a pair of symmetri-
cally placed ports on the pitot head. The yaw angle is measured
with a remote inclinometer attached to the probe extension and
digitally displayed on the console.
The pitch angle is calculated using probe specific calibration
curves. The average gas volumetric flow rate in the
stack or duct is then determined from the average axial velocity.

3DPT2
5 Hole Prism-
Shaped Pitot

3-D PITOT CALIBRATION (PT-CAL-3D)


All 3-D pitot tubes must be calibrated before use. Re-calibration is also required either within 12 months of its first field use after its
most recent calibration or after 10 field tests, whichever occurs later. In addition, whenever there is visible damage to the 3-D head,
the pitot should be re-calibrated before it is used again.

8 INTERNET: WWW.APEXINST.COM PHONE: 800-882-3214 / 919-557-7300


FLOW MEASUREMENT EQUIPMENT

INCLINOMETERS

PROTRACTOR / INCLINOMETER
The M5C-4 Protractor/Inclinometer is an ideal tool
for measuring cyclonic yaw angles in accordance
with Method 2. The machined aluminum frame
and integral baseplate provide a light, rigid and
ultra-precise platform allowing the state-of-the-art
sensor to provide unsurpassed accuracy throughout
the 360° range. The inclinometer can be securely
attached to a probe with one of the following
mounting brackets.
M5C-4

Mounting Brackets for M5C-4


Bracket for M5C-4 with 1” Aluminum Clamp.
M5C-4-16
Bracket for M5C-4 with 2” Aluminum Clamp.
M5C-4-32

Pendulum Style Inclinometer


Easy to use, hand-held Pendulum Style Inclinometer.
1 degree accuracy.
2.6" diameter dial with verier divisions of 1 degree.
Height: 3.6"
Weight: 8.6 oz.
M5C-1
M5C-1-16 (Bracket for M5C-1 with 1” Aluminum Clamp)
M5C-1-32 (Bracket for M5C-1 with 2” Aluminum Clamp)

Additional Pitot Calibration Equipment


Bull’s Eye Level, 1/2 Inch Diameter
M5C-2
Dail Caliper, 0-6 inch, 0.001 inch Increments, English Only
M5C-3
Dial Caliper, 0-6 inch/150mm Direct Inch/Metric Conversion
M5C-3D

EMAIL: INFO@APEXINST.COM INTERNET: WWW.APEXINST.COM 9


FLOW MEASUREMENT EQUIPMENT

VELOCITY MEASUREMENT
DELUXE METHOD 2 PRETEST SURVEY KIT SK-DM2D Survey Kit
The Deluxe Method 2 Pretest Survey Kit contains a modular
pitot tip and extension for stacks up to 12’, a digital hand held
manometer, thermocouple thermometer, tubing, reducers, unions
and flexible thermocouples. The kit is packaged in a sturdy, foam-
lined case- dimensions 45" L x 15.25 W x 9.5" D. Custom kits
available. Alternative manometer options available upon request.
SK-DM2D

DELUXE METHOD 2 MAGNEHELIC KIT


Includes all items of the SK-DM2D (Listed Above) with 4 Magne-
helic Gauges: 0 to 0.25”H2O, 0 to 2” H2O, 0 to 5” H2O, and 0 to 10”
H2O in lieu of digital manometer (English Units).
SK-DM2

DELUXE METHOD 2 METRIC MAGNEHELIC KIT


Includes all items of the SK-DM2D (Listed Above) with 4 Magnehe-
lic Gauges: 0-.25CM H2O, 0-6 mm H2O, 0-50 mm H2O, and 0-100
mm H2O in lieu of digital manometer (Metric Units).
SK-DM2M

PRESSURE AND TEMPERATURE DISPLAY


Features:
• Lightweight and Sturdy Transport Case with Handle
• Bright Backlighted Red LED Digital Temperature and Pressure Displays
• Utilizes 120VAC/15Aamp Power with IEC male receptacle
• 12VDC, 25 Watt Power Supply
• 15 Amp Panel Mounted Breaker Switch
• Temperature Compensated Pressure Transducer with +/-5" H2O range
• Operating Range of 0-70°C
• Relative Humidity Operating Range of 0-95%
• 1/4" Female Quick Connects
• Type K Female Thermocouple Jack, Range -157 to 1999°F
• 4.5 lbs without power cord, 5 lbs with power cord
DPT-B5

AIR VELOCITY KIT


The M-115AV Air Velocity Kit includes an Inclined Portable Manometer with a range of -.05” to 0.25” H2O with 0 to 0.5”
minor scale divisions, standard 12” pitot, hoses and a case. The Low-Flow Air Velocity Manometer can be ordered sepa-
rately.
Custom Kits Available.
Features:
• 1” Thick Acrylic Plastic Body
Manometer
• Drilled Bore Accurate to
M-115G (English Units) ±.0002 inches
M-115M (Metric Units) • Selected Gauge Oil
• Adjustable Reflective
Chrome Finish
Pitot
• Parallax-Free Reading
166-12
• Screw Type Leveling Adjustment

10 INTERNET: WWW.APEXINST.COM PHONE: 800-882-3214 / 919-557-7300


FLOW MEASUREMENT EQUIPMENT

DUAL SCALE PORTABLE INCLINED-VERTICAL MANOMETER


The M-400K Air Velocity Kit includes Dual Scale Portable Inclined-Veritical Manometer (M-400G) with an inclined range of
0-1.0” H2O with .01” minor divisions and vertical range of 1 to 10” H2O with 0.10” minor divisions, 18” standard pitot, 160-12 pitot,
hoses and case (M-400G Manometer can be ordered separately).
M-400K

Manometer
Features:
M-400G
• 1 1/4” Thick Acrylic • Ground Glass
Plastic Body Bubble Level
• 3/16” Bores, Accurate to • Parallax-Free Reading
±.0002” • O-Ring sealed
• Selected gauge oil Fluid Level plunger
Adjustment
Pitot
160-12

TRANSDUCERS/TRANSMITTERS

M-DP TRANSDUCERS / TRANSMITTERS


Features:
• Temperature Compensated Pressure Transducers
• Built into 4.4” x 2.4” x 1.1” Enclosure with Terminal Blocks
• Accessible Hose Barbs for Pressure Connections M DP
(barbs OD=.174 -.190)
• Built-In ESD Protection
• 12 VDC Power Required from Separate Source
• Operating Range of 0-70°C
• Relative Humidity Operating Range of 0-95%
• Ratio Metric 4vdc Span Output
(exact output value is sensor dependent)
• On-board Regulated Reference Supply for Pressure Sensors

CALIBRATION PUMP
Serves as pressure source to calibrate gages and transmitters
or to set pressure switches. Includes volume adjuster enabling
fine pressure control and bleed valve. Use with manometer or
other pressure standard.

A-396A

ROLL-UP MANOMETER
Roll-Up Manometer, Range 18-0-18”, quick shut off hose barb
connections.

M1211-36

EMAIL: INFO@APEXINST.COM INTERNET: WWW.APEXINST.COM 11


FLOW MEASUREMENT EQUIPMENT

HAND HELD DIGITAL MANOMETERS


DHM28-10 DIGITAL HANDHELD MANOMETER
The DHM28-10 is a precision instrument designed to measure a wide range of pressures to a very high
accuracy. Features include: measurement in all common pressure ranges, display resolution to .001,
differential or relative measurement, two line liquid crystal display, and adjustable auto power off to con-
serve battery. A certificate of calibration is included with the unit at no additional cost. The DHM28-10 can
be used as a secondary calibration standard for your other pressure instrumentation.
DHM28-10
Features:
• Microprocessor-Based • Programmable Display
• Differential Gage, or Absolute • Memory for up to 964 Readings
• High Accuracy, 0.2%, 0.1%, or 0.5% • Output for Optional Printer or
with Calibration Certificate • Computer Interface
• Selectable Scales Input Range; US 0-10” in H2O,
• Resolution to 0.000 of Selected Unit Metric 0-2.5 kPa, Overpressure
• Accuracy, ±0.20% Full Scale ±1 Digit 12.5 kPa (50 in H2O)
• Hold Function

DWYER DIGITAL HANDHELD MANOMETER


The D477AV-0 Dwyer handheld manometer provides pressure, flow, and velocity measurements along
with a number of other convenient features. The D477AV-0 (0-10 inch H20) uses a highly accurate dif-
ferential pressure sensor to offer ± 0.5% full scale accuracy. The accuracy provided is critical to mainte-
nance personnel and technicians who require a highly accurate standard to check their instrumentation or
equipment, to ensure proper performance.
D477AV-0
D477AV-0-FC Factory Certification
D477AV-0-NIST NIST Certification
Features:
• Calculates and displays air velocity and volumetric air flow
• Rugged aluminum case protects instrument from damage during transport/use
• 9 selectable English and metric engineering units
• Large, easy to read display with backlight for use in dark areas
• Stores up to 40 readings with minimum, maximum and average statistics

BAROMETERS
ANALOG DIAL BAROMETER
Traceable Precision Dial Barometer’s Triple scales provide a sensitive measure of atmospheric
pressure from 954 to 1073 millibars (28.1-31.7 inches mercury 715 to 805 millimeters of mercury).
Resolution of 0.5 mbar, 0.05 InHg, or 0.5 mmHg with an accuracy of ±0.5%. NIST Traceable for
accuracy. To assure accuracy an individually serial-numbered Traceable Certificate is provided from our
ISO 17025 calibration laboratory accredited by A2LA. Rugged, corrosion-proof nickel-chrome housing.
Adjustable pointer may be set to indicate changes. Complete with altitude adjustment screw (use at
locations as high as 1000 meters), notched desk stand, and wall mount. Size is 4-1/8” diameter by 1-1/2”
deep. Weight is 1 Lb.
BAR-2831

DIGITAL BAROMETER
Traceable Digital Barometer is the perfect unit where there is a need to monitor conditions of
environmental air parameters. A four-line LCD continuously and simultaneously shows barometric
pressure, temperature, relative humidity, barometric pressure trend and time-of-day. Minimum\Maximum
readings for barometric pressure, temperature and relative humidity are stored every hour for the last
24 hours and are available for recall at the touch of a button. HI/LO alarms can be set for barometric
pressure, temperature, and relative humidity.

Barometric pressure range from 500 to 1030 millibars (mbar) with a resolution of 1 mbar. Accuracy is ±4
mbar. Barometric pressure trend shows in bar-chart format the current and past 1-, 3-, 6-, 12-, and 24-
hour readings. Switching permits viewing in milibars (mbar), inches of mercury (inHg), or hectopascals
(hPa). Altitude compensation is –100 to 2500 meters.

Temperature range is 32 to 131ºF and 0 to 55ºC. Resolution is 0.1° and accuracy is ±0.4°C. Relative
humidity range is 5 to 95%. Resolution is 1% RH and accuracy is ±3% RH between 5 to 75%, otherwise
±5% RH.
BAR-6530

12 INTERNET: WWW.APEXINST.COM PHONE: 800-882-3214 / 919-557-7300


FLOW MEASUREMENT EQUIPMENT

TEMPERATURE THERMOMETERS AND TRANSMITTERS


WATERPROOF THERMOMETER
The Waterproof Thermometer has membrane switches, ABS body, and stainless steel
probe, good for use in labs, plants, wash-down areas, and the field. Unit eliminates
the dangers inherent in breakable glass and toxic mercury thermometers. It displays
minimum and maximum readings over any period. Unique holder allows probe to be
positioned at any height while attached to beakers, stainless cylinders, or vats. Probe
guard snaps to handle to extend overall length to 10.75”. Readings are updated every
second. Supplied with probe holder, key chain, and lanyard. Operates continuously for
1.5 years on supplied replaceable silver-oxide battery.
DPT-168-NIST

Specifications:
Range: -58 to 572°F and –50 to 300°C. Dimensions: stem length, 3.25” inches;
Resolution: is 0.1° from –20 to 200° (1° stem diameter is 0.14”; overall length is
otherwise). 7.25”. Weight is 1 oz.
Accuracy: ±0.4°C or ±1.5°C.

MODEL VA710 (V & A INSTRUMENTS) THERMOCOUPLE SIMULATOR


The VA710 Thermocouple Calibrator is a precision source and measurement tool for
calibrating thermocouple instruments. The calibrator measures through a thermocouple jack.
Measuring units are °C,°F or MV. The V&A Instrument Model VA710 Thermocouple Simula-
tor simulates a dedicated standard thermocouple curve over the entire industrial temperature
range.
M5C-VA710

WORKHORSE THERMOMETER
Type-K Workhorse™ Thermometer provides a sharp readout in dim and very bright light,
long battery life (150 to 200 continuous hours), high accuracy, wide temperature range, and
a new chip design for an ultra low Price. Recessed front panel adjustable offset allows user
to adjust thermometer exactly to a specific temperature, in-house calibration, or a particular
sensor for increased accuracy. HOLD button freezes display to capture current reading.
Supplied with bench stand. It is compatible with all Type-K probes. Supplied with fast
response Type-K probe, bench stand, 9-volt battery, and carrying case. Cable length of 40
inches.
TC-4425
Specifications:
Range: -58.0 to 2372°F and -50.0 to 1300°C. Resolution: 0.1° between –50.0 to 200.0
Accuracy: ±(1°C + .75%) between 0 to and 1° elsewhere
500°C; ±(1°C + 1%) 500 to 750°C; ±(1°C + Probe dimensions: length is 5” and .175”
2%) 750 to 1000°C; ± (3°C + 4%) 1000 to diameter .
1200°C; ±2°C at –20; ±3°C at –40; and ±4°C Thermometer Dimensions: 2.75” x 5.5” x
at –50). 1.25” ( cm x cm x cm); 6 oz ( kg).

THERMOCOUPLE
Type K Stainless Steel Probe- Triple Purpose (liquid, air/gas, semi-solids)
Temperature Range -45° to 230°C, Probe Length is 5 inches with 30 inch cable
TPK-8595

M-TC4C FOUR CHANNEL THERMOCOUPLE TRANSMITTER


Features:
• TVS Diodes on TC Input for ESD and Transient Suppression
• DC-DC Converter on 12V Power input Providing 1000V Power Surge Isolation
• Designed using Analog Devices AD595CQ TC Amplifier with Cold Junction Compensation,
Low Input Impedance and +/- 1°C Accuracy
• Low Power Consumption (less than 40ma for all 4 channels)
• Type K Thermocouple Range Capable

THERMOCOUPLE TRANSMITTER
4-Channel Thermocouple Transmitter. 4.4 x 2.4 x 1.1 ABS plastic enclosure with terminal
blocks. Designed using Analog Devices AD595CQ TC amplifier with cold junction compensa-
tion. Low input impedance and +/- 1 degree C accuracy.
M-TC4C

EMAIL: INFO@APEXINST.COM INTERNET: WWW.APEXINST.COM 13


FLOW MEASUREMENT EQUIPMENT

HUMIDITY

Sling Psychrometer
Red Spirit Filled Thermometer with a Range of 20° to
120°F. It is fast and accurate with no assembly required.
Includes high impact on plastic construction.

B12-7012

DEW-POINT/WET-BULB/HUMIDITY/THERMOMETER
Monitor shows current, minimum, & maximum displays
and includes a high/low alarm setting for all four read-
ings (dew-point, wet-bulb, humidity, temperature).
Supplied with two AA alkaline batteries for continuous,
1-year “always on” monitoring, and Traceable® Certifi-
cate. LCD digits are 1-inch-high. Case is high-impact,
chemical-resistant ABS plastic.

HUM-4410

Specifications:
Temperature Range: –40 to 70 °C and –40 to 158°F
Resolution: 0.1° (below 100. Accuracy: ±1°C
Relative Humidity Range: 1 to 99%
Resolution: 0.1%RH. Accuracy: ±4% between 20 to 80%
Dimensions: HxWxD 4.125” x 4.125” x 1”. Weight is 4.25 ounces

Dial Hygrometer/Thermometer:
Features:
Precision hygrometer with Temperature Gauge
Temperature from -40 f to 122F (-40 C to 50 C)
Resolution is 1 % RH and 1
Accurate within 2.5%RH at 50%RH and 1.5 C
Relative Humidity from 0% to 100%
6 inch diameter X 1 inch - 8 oz.

HUM-4186

14 INTERNET: WWW.APEXINST.COM PHONE: 800-882-3214 / 919-557-7300


FLOW MEASUREMENT EQUIPMENT

MAGNEHELIC GAUGES
Easy to read 4” dials indicate gas pressures; positive, negative or differential.
The gauges have a + 2% full scale accuracy and include simple, frictionless
magnehelic magnetic movement. They are highly resistant to shock, vibration
and overpressure.

STANDARD MEASURE
METRIC MEASURE
MAG-2000-00 0-1/4” H2O
MAG-2000-6MM 0 to 6 mm H2O
MAG-2000-0 0-1/2” H2O
MAG-2000-25MM 0 to 25 mm H2O
MAG-2001 0-1” H2O
MAG-2000-50MM 0 to 50 mm H2O
MAG-2002 0-2” H2O MAG-2000-00
MAG-2000-100MM 0 to 100 mm H2O
MAG-2005 0-5” H2O (Shown with A-369 Stand)

MAG-2010 0-10” H2O


A-369 Stand, Aluminum, 5 1/2” Tall

Magnehelic Gauge Mounting Assembly:


Magnehelic Gauge, +-.5 INWC Differential
MAG-2301-BK

Optional Accessories:
Magnehelic Gauge: Magnehelic Bracket:
Magnehelic Gauge, +-.5 INWC Differential Magnehelic Mounting Bracket
MAG-2301 MAG-2D-BK

EMAIL: INFO@APEXINST.COM INTERNET: WWW.APEXINST.COM 15

Vous aimerez peut-être aussi