Nokia AirScale Radio Description AirScale RRH 2T2R B3 120W (FHEL)

7 AirScale RRH 2T2R B3 120W (FHEL)


FHEL technical specifications.
Functional description

Table 2 FHEL functional specification
Property Value
Output power 2x60 W

MIMO 2TX
DRAFT VERSION

Outdoor installation Yes
SW supported technology FDD-LTE
TX frequency range 1805 - 1880 MHz
RX frequency range 1710 - 1785 MHz
DL instantaneous bandwidth 75 MHz
37.5 MHz in GSM

UL instantaneous bandwidth 75 MHz
DL filter bandwidth 75 MHz
UL filter bandwidth 75 MHz

Interfaces

Figure 2 FHEL interfaces
FAN DCIN OPT2 OPT1 RET GND

ANT2 EAC ANT1


Table 3 FHEL interfaces
Interface Label on the HW Number of Connector type Additional info
interfaces
Power Connector DC IN 1 3-pole screw
terminal
Antenna ANT 2 4.3-10
connector
Remote Electrical RET 1 8-pin circular RS-485
Tilt

Issue: 01 DRAFT DN09236379 13
   

AirScale RRH 2T2R B3 120W (FHEL) Nokia AirScale Radio Description

Table 3 FHEL interfaces (Cont.)
Interface Label on the HW Number of Connector type Additional info
interfaces
External Alarm EAC 1 USB 3.0 Type-A
Connection
Optical interface OPT 2 SFP+ 6 Gbps, OBSAI
Ground 1 M8 or dual M5
screws

Fan Fan 1 2 circuits Micro-


Fit
DRAFT VERSION

Antenna Line Devices (ALDs) support

Table 4 FHEL ALD support
ALD support via antenna ports Value
AISG ANT1, RET: AISG 2.0
Proprietary AISG1.1 No
CWA (for non-AISG installations) No
Voltage ANT1: 14.5 V
RET: 14.5 V

Power per port 40 W
Power 30 W

Functional block diagram

Figure 3 FHEL functional block diagram

RRH Filter

LMP
TX
PA filter Bias-T VSWR
UniTX Tx/Rx
FPGA Det ANT 1
RX
OpticalIF filter
RF LNA
control
TX
PA filter VSWR
Tx/Rx
OpticalIF UniRx Det ANT 2
RX
filter
LNA

DCIN
PSU
BWextension

Electrical specifications

Table 5 FHEL electrical specifications
Property Value
Nominal supply voltage -48.0 V DC
Nominal input voltage range -40.5 V DC to -57.0 V DC

14 DN09236379 Issue: 01 DRAFT
   

Nokia AirScale Radio Description AirScale RRH 2T2R B3 120W (FHEL)

Table 5 FHEL electrical specifications (Cont.)
Property Value
Extended input voltage range -36.0 V DC to -40.5 V DC
-57.0 V DC to -60.0 V DC

Power consumption

g Note: This information will be provided in further release.
Installation and mechanical specifications
DRAFT VERSION

Table 6 FHEL installation and mechanical specifications
Property Value
Installation options • wall installation
• pole installation
• flat mount on wall or pole
• face mount without fans
• vertical book mount without fans
• horizontal book mount with fans
• inside the Radio Antenna System (RAS)
with/without fans

IP rating IP65
Related optional items • Pole Mounting Kit 30-120 mm (AMPA)
• 2T2R AirScale REL4 Fan Assembly
• 4T4R AirScale REL4 Fan Assembly
• Flexi Power AC/DC Submodule 230V
(FPAD/E)
• EAC Cable USB3 Type-A (ATAA)
• Flat Mount Adapter Bracket (AMLA)

Dimensions and weight

Table 7 FHEL dimensions and weight
Property Value Dimensions orientation
Height With cover: 600 mm (23.6 in.) Dimensions orientation in
vertical mount with cover
With cover and fan: 630.2 mm
(24.8 in.)

Depth With cover and handle: 409.5:
mm (16.1 in.)
With cover, fan and handle:
409.5 mm (16.1 in.)
width
Width With cover: 80 mm (3.1 in.)
With cover and fan: 80 mm height
(3.1 in.) depth

Issue: 01 DRAFT DN09236379 15
   

AirScale RRH 2T2R B3 120W (FHEL) Nokia AirScale Radio Description

Table 7 FHEL dimensions and weight (Cont.)
Property Value Dimensions orientation
Weight 12.5 kg (27.5 lbs) Dimensions orientation in
horizontal mount with cover
and fan

Volume With cover: 18 l width


Without cover: 12.5 l
height
DRAFT VERSION

depth

Environmental specifications

Table 8 FHEL environmental specifications
Property Value
Maximum operational outdoor temperature in +55°C (131°F)
the shade, assuming wind speed is 3 m/s (at
constant high ambient temperature, maximum
output power might be limited)
Maximum operational outdoor temperature in +50°C (122°F)
the sun, assuming wind speed is 3 m/s (at
constant high ambient temperature, maximum
output power might be limited)
Maximum indoor temperature, assuming wind +40°C (104°F)
speed is 0 m/s, valid for fanless products (at
constant high ambient temperature, maximum
output power might be limited)
Minimum operational temperature (including -40°C (-40°F)
cold start)

LEDs

Table 9 FHEL LEDs
LED color Description Alarm
Red, stable Critical alarm affecting the Fault
whole RF module or all
antenna carriers
Red, blinking Operation degraded Major/critical alarm
• Major alarm affecting the
whole RF Module
• Critical alarm affecting
fans
• Major/Critical alarm
affecting a module
subcomponent or antenna
carrier

Yellow, stable • Until software download No alarm


begins

16 DN09236379 Issue: 01 DRAFT
   

Nokia AirScale Radio Description AirScale RRH 2T2R B3 120W (FHEL)

Table 9 FHEL LEDs (Cont.)
LED color Description Alarm
• The carriers are blocked
from BTS
• There is no connection to
any System Module

Yellow, blinking • Software download in No alarm


progress
• Configuration in progress:
RF resources are being
setup, but not yet activated
DRAFT VERSION

Green, stable • Software configuration is No alarm


complete or supervisory:
RF resources activated
and transmission is
possible
• Working normally, no
alarm on the RF Module

Green, blinking Software downloading and No alarm


updating
Stable Red for less than 5 Switched ON, but the next No alarm
seconds and changes to conditions are not reached yet
Stable Yellow
Stable Red for less than 5 The module is in the process No alarm
seconds of resetting
Periodic Red and Green Antenna line device No alarm
faulty/degraded
Blinking Colors (Red, Yellow, Module highlighting (Flexi BTS No alarm
and Green), each color stable SM functionality that can help
for 0.5 second identifying faulty module)

Warnings, cautions or notes related to the product

f WARNING! The module is heavy. Risk of personal injury!


Do not remove or relocate factory installed stopping screws from mounting brackets or
AMPA.

f WARNING! Lift only one module at a time!


Use the designated lifting point only. Do not pre-assemble and lift multiple units on
AMPA.

f WARNING! Install only three modules per side in vertical book mount!
Mount the secondary center module bracket to the pole bracket with four M8 screws.
Only one module is allowed on each side of the center bracket.

f WARNING! Do not connect secondary brackets in wall installation!


Mount each module to its own secondary bracket and install each secondary bracket to
the wall individually.

w NOTICE: To ensure proper cooling for an RRH mounted in the vertical position, it
should always be mounted with the connectors on the bottom side. For horizontal
mounting, fans are required.

Issue: 01 DRAFT DN09236379 17

Vous aimerez peut-être aussi